HomeMy WebLinkAboutAPPROVED PLANS - 23-00159 - 1000 Westwood Dr - Solar PanelsAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Alex Owens Alex.Owens@rexburg.org 208-372-2172
Description : 1000 Westwood Dr - Solar Panels
Address : 1000 Westwood Dr
Record Type : Solar Panels
Document Filename : Jonathon Egan PROJ-3473 + SS.pdf
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Approved
# 23-00159
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
PV-1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector
PV-2 Rectangle Larry Beesley : Building Open 2
PV-2 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector
Pg 12 Stamp Larry Beesley : Building Open 12 Approved - Building Inspector
PV-1 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector
PV-3 Stamp Alex Owens : Electrical Open 3 Approved - Electrical Inspector
PV-3 Free Text Alex Owens : Electrical Open 3 Please call for rough inspection once rooftop equipment is on
site and prior to installation on roof. Thanks
Solar Panels
Approval of plans does not constitute approval of variance from code
Powered by TCPDF (www.tcpdf.org)
P
L
A
N
S
E
T
L
E
G
E
N
D
S
H
E
E
T
I
N
D
E
X
V
I
C
I
N
I
T
Y
M
A
P
A
P
P
L
I
C
A
B
L
E
C
O
D
E
S
A
B
B
R
E
V
I
A
T
I
O
N
S
P
R
O
J
E
C
T
I
N
F
O
R
M
A
T
I
O
N
P
V
-
1
C
O
V
E
R
P
A
G
E
P
V
-
2
S
I
T
E
P
L
A
N
,
A
E
R
I
A
L
V
I
E
W
P
V
-
3
E
L
E
C
T
R
I
C
A
L
L
I
N
E
D
I
A
G
R
A
M
A
N
D
N
O
T
E
S
P
V
-
4
E
L
E
C
T
R
I
C
A
L
C
A
L
C
U
L
A
T
I
O
N
S
P
V
-
5
R
E
Q
U
I
R
E
D
S
I
G
N
A
G
E
ISSUED FOR: PERMIT DATE
03/30/2023
www.bigdogenergy.com
SOLAR PHOTOVOLTAIC SYSTEM
JONATHON EGAN
DESIGNED BY CONTRACTOR INFORMATION
P
V
-
1
1000 WESTWOOD DR.,
REXBURG, ID 83440
BIG DOG RENEWABLE ENERGY
CONTRACTOR LIC #: IDAHO #017916
620 PHEASANT RIDGE DR
CHUBBUCK, ID 83202
208-242-3352 T
208-232-5935 F X__________________
(
E
)
E
X
I
S
T
I
N
G
(
N
)
N
E
W
E
X
T
E
X
T
E
R
I
O
R
I
N
T
I
N
T
E
R
I
O
R
E
M
T
E
L
E
C
T
R
I
C
A
L
M
E
T
A
L
L
I
C
T
U
B
I
N
G
R
M
T
R
I
G
I
D
M
E
T
A
L
L
I
C
T
U
B
I
N
G
F
M
C
F
L
E
X
I
B
L
E
M
E
T
A
L
L
I
C
C
O
N
D
U
I
T
V
O
C
V
O
L
T
A
G
E
O
P
E
N
C
I
R
C
U
I
T
V
M
P
V
O
L
T
A
G
E
A
T
M
A
X
.
P
O
W
E
R
I
S
C
S
H
O
R
T
C
I
R
C
U
I
T
C
U
R
R
E
N
T
I
M
P
C
U
R
R
E
N
T
A
T
M
A
X
.
P
O
W
E
R
N
T
S
N
O
T
T
O
S
C
A
L
E
MSPSUBACDCSLCMINVJBCBBAT
M
A
I
N
S
E
R
V
I
C
E
P
A
N
E
L
S
U
B
S
E
R
V
I
C
E
P
A
N
E
L
A
C
D
I
S
C
O
N
N
E
C
T
D
C
D
I
S
C
O
N
N
E
C
T
S
O
L
A
R
L
O
A
D
C
E
N
T
E
R
M
O
N
I
T
O
R
I
N
G
M
E
T
E
R
I
N
V
E
R
T
E
R
J
U
N
C
T
I
O
N
B
O
X
C
O
M
B
I
N
E
R
B
O
X
B
A
T
T
E
R
Y
P
V
P
R
O
D
U
C
T
I
O
N
M
E
T
E
R
R
A
P
I
D
S
H
U
T
D
O
W
N
D
I
S
C
O
N
N
E
C
T
PMRSD
J
O
N
A
T
H
O
N
E
G
A
N
1
0
0
0
W
E
S
T
W
O
O
D
D
R
.
,
R
E
X
B
U
R
G
,
I
D
8
3
4
4
0
(
N
)
2
-
Q
.
P
E
A
K
D
U
O
B
L
K
M
L
-
G
1
0
+
4
0
0
(
4
0
0
W
)
(
E
)
1
7
-
Q
.
P
E
A
K
D
U
O
B
L
K
M
L
-
G
1
0
+
4
0
0
(
4
0
0
W
)
P
H
O
T
O
V
O
L
T
A
I
C
M
O
D
U
L
E
S
(
E
)
1
-
S
O
L
A
R
E
D
G
E
S
E
6
0
0
0
H
-
U
S
W
I
T
H
P
R
I
S
M
T
E
C
H
N
O
L
O
G
Y
(
6
0
0
0
W
)
I
N
V
E
R
T
E
R
(
S
)
(
N
)
1
-
S
O
L
A
R
E
D
G
E
-
1
0
K
1
P
S
0
B
-
0
1
B
A
T
T
E
R
Y
(
I
E
S
)
T
O
T
A
L
S
Y
S
T
E
M
S
I
Z
E
:
7
.
6
0
0
K
W
D
C
S
T
C
T
O
T
A
L
A
R
R
A
Y
A
R
E
A
:
4
0
1
.
5
8
S
F
1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2. ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6. ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8. DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALLLOCAL ORDINANCES AND POLICIES.9.THE PROJECT HAS BEEN DESIGNED TO WITHSTAND A MINIMUM 115 MPH WIND LOAD.10.THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND A UTILITY IS OBTAINED.11.IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTORS RESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDING ELECTRODE.12.EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURERS INSTALLATION INSTRUCTIONS.13.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.14.PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED "WARNING: PV POWER SOURCE" TO BE PLACED EVERY 10 FT.15.GFCI PROTECTION IN INVERTER.
A
L
L
W
O
R
K
T
O
C
O
M
P
L
Y
W
I
T
H
T
H
E
F
O
L
L
O
W
I
N
G
C
O
D
E
:
N
E
C
2
0
1
7
C
O
D
E
I
B
C
/
I
R
C
/
I
F
C
2
0
1
8
C
O
D
E
ADDITIONAL NOTESOCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED ALL CONDUIT TO RUN ON EXTERIOR OF HOUSE UNLESSOTHERWISE NOTED COVER PAGE
COVER PAGE
4/4/2023
MSPACMTRINVRSDSBIBATBP
A
E
R
I
A
L
V
I
E
W
SITE PLAN, AERIAL VIEW
N
ISSUED FOR: PERMIT DATE
03/30/2023
www.bigdogenergy.com
SOLAR PHOTOVOLTAIC SYSTEM
JONATHON EGAN
DESIGNED BY CONTRACTOR INFORMATION
P
V
-
2
1000 WESTWOOD DR.,
REXBURG, ID 83440
BIG DOG RENEWABLE ENERGY
CONTRACTOR LIC #: IDAHO #017916
620 PHEASANT RIDGE DR
CHUBBUCK, ID 83202
208-242-3352 T
208-232-5935 F X__________________
R
O
O
F
D
E
S
C
R
I
P
T
I
O
N
R
O
O
F
A
R
R
A
Y
P
I
T
C
H
A
Z
I
M
U
T
H
#
1
1
5
°
2
7
1
°
#
2
1
5
°
1
8
1
°
SITE PLAN(NEW + EXISTING)TOTALSYSTEMDC SIZE / AC SIZE:7.600 KW-DC / 6.000 KW-AC
A
B
B
R
E
V
I
A
T
I
O
N
S
S
C
A
L
E
:
N
T
S
S
C
A
L
E
:
N
T
S
PANEL PLACEMENT MAY DIFFER FROMAPPROVED DESIGN DUE TO UNFORESEENOBSTRUCTIONS OR PERMITTING SETBACKS
(
N
)
S
O
L
A
R
P
V
M
O
D
U
L
E
(
E
)
S
O
L
A
R
P
V
M
O
D
U
L
E
I
N
V
(
E
)
I
N
V
E
R
T
E
R
M
S
P
(
E
)
M
A
I
N
S
E
R
V
I
C
E
P
A
N
E
L
A
C
(
E
)
A
C
D
I
S
C
O
N
N
E
C
T
M
T
R
(
E
)
M
E
T
E
R
B
A
T
(
N
)
B
A
T
T
E
R
Y
S
B
I
(
N
)
S
O
L
A
R
E
D
G
E
B
A
C
K
U
P
I
N
T
E
R
F
A
C
E
B
P
(
N
)
B
A
C
K
U
P
P
A
N
E
L
R
S
D
(
N
)
R
A
P
I
D
S
H
U
T
D
O
W
N
D
I
S
C
O
N
N
E
C
T
(NEW+EXISTING)TOTAL # OFMODULES TOTAL ARRAYAREA(Sq. Ft.)
T
O
T
A
L
R
O
O
F
A
R
E
A
(
S
q
.
F
t
.
)
R
O
O
F
A
R
E
A
C
O
V
E
R
E
D
B
Y
A
R
R
A
Y
(
%
)
19401.58
1
9
2
0
.
5
0
2
0
.
9
1
WESTWOOD DR.
3'PATHWAY 3'PATHWAY18"CLEARANCE18"CLEARANCE 18"CLEARANCE 18"CLEARANCEROOF #1ROOF #2 EXISTING TOTAL # OFPANELS:17 NEW TOTAL # OFPANELS:2 RO
O
F
T
Y
P
E
:
CORRU
G
A
T
E
D
M
E
T
A
L
A
C
D
I
S
C
O
N
N
E
C
T
W
I
T
H
I
N
3
’
F
R
O
M
U
T
I
L
I
T
Y
M
E
T
E
R
4
/
4
/
2
0
2
3
E
L
E
C
T
R
I
C
A
L
N
O
T
E
S
SINGLE LINE DIAGRAM
R
A
C
K
I
N
G
&
M
O
D
U
L
E
S
A
R
E
G
R
O
U
N
D
E
D
V
I
A
A
C
O
N
T
I
N
U
O
U
S
#
6
A
W
G
C
O
P
P
E
R
C
O
N
D
U
C
T
O
R
C
O
N
N
E
C
T
E
D
W
/
W
E
E
B
S
-
M
O
D
U
L
E
S
A
R
E
F
A
C
T
O
R
Y
P
R
O
V
I
D
E
D
W
/
2
T
H
R
E
A
D
E
D
H
O
L
E
S
T
O
F
A
C
I
L
I
T
A
T
E
L
A
N
D
I
N
G
O
F
T
H
E
L
U
G
S
A
L
L
E
Q
U
I
P
M
E
N
T
S
H
A
L
L
B
E
P
R
O
P
E
R
L
Y
G
R
O
U
N
D
E
D
A
N
D
B
O
N
D
E
D
I
N
A
C
C
O
R
D
A
N
C
E
W
I
T
H
A
R
T
I
C
L
E
2
5
0
.
A
L
L
C
I
R
C
U
I
T
S
C
O
N
N
E
C
T
E
D
T
O
M
O
R
E
T
H
A
N
O
N
E
S
O
U
R
C
E
S
H
A
L
L
H
A
V
E
O
V
E
R
C
U
R
R
E
N
T
D
E
V
I
C
E
S
L
O
C
A
T
E
D
S
O
A
S
T
O
P
R
O
V
I
D
E
O
V
E
R
C
U
R
R
E
N
T
P
R
O
T
E
C
T
I
O
N
F
R
O
M
A
L
L
S
O
U
R
C
E
S
6
9
0
.
9
(
A
)
ISSUED FOR: PERMIT DATE
03/30/2023
www.bigdogenergy.com
SOLAR PHOTOVOLTAIC SYSTEM
JONATHON EGAN
DESIGNED BY CONTRACTOR INFORMATION
P
V
-
3
1000 WESTWOOD DR.,
REXBURG, ID 83440
BIG DOG RENEWABLE ENERGY
CONTRACTOR LIC #: IDAHO #017916
620 PHEASANT RIDGE DR
CHUBBUCK, ID 83202
208-242-3352 T
208-232-5935 F X__________________
A
L
L
M
O
D
U
L
E
S
W
I
L
L
B
E
G
R
O
U
N
D
E
D
I
N
A
C
C
O
R
D
A
N
C
E
W
I
T
H
C
O
D
E
A
N
D
T
H
E
M
A
N
U
F
A
C
T
U
R
E
R
'
S
I
N
S
T
A
L
L
A
T
I
O
N
I
N
S
T
R
U
C
T
I
O
N
S
.
M
O
D
U
L
E
:
Q
.
P
E
A
K
D
U
O
B
L
K
M
L
-
G
1
0
+
4
0
0
(
4
0
0
W
)
V
o
c
=
4
5
.
3
0
V
I
s
c
=
1
1
.
1
4
A
V
m
p
=
3
7
.
1
3
V
I
m
p
=
1
0
.
7
7
A
P
R
O
P
O
S
E
D
S
Y
S
T
E
M
D
C
S
I
Z
E
/
A
C
S
I
Z
E
:
7
.
6
0
0
K
W
-
D
C
/
6
.
0
0
0
K
W
-
A
C
1
.
P
V
A
R
R
A
Y
S
A
R
E
P
E
R
S
I
N
G
L
E
L
I
N
E
.
2
.
P
V
A
R
R
A
Y
W
I
R
I
N
G
T
O
J
U
N
C
T
I
O
N
I
S
#
1
0
A
W
G
U
S
E
2
W
/
F
I
E
L
D
I
N
S
T
A
L
L
E
D
M
C
C
O
N
N
E
C
T
O
R
S
T
O
I
N
T
E
R
F
A
C
E
W
/
M
O
D
U
L
E
S
.
3
.
P
V
A
R
R
A
Y
C
O
M
B
I
N
E
R
/
J
U
N
C
T
I
O
N
B
O
X
P
R
O
V
I
D
E
S
T
R
A
N
S
I
T
I
O
N
F
R
O
M
A
R
R
A
Y
W
I
R
I
N
G
T
O
C
O
N
D
U
I
T
W
I
R
I
N
G
.
4
.
U
S
E
U
F
E
R
G
R
O
U
N
D
E
L
E
C
T
R
O
D
E
S
Y
S
T
E
M
F
R
O
M
I
N
V
E
R
T
E
R
T
O
E
X
I
S
T
I
N
G
M
A
I
N
S
E
R
V
I
C
E
G
R
O
U
N
D
E
L
E
C
T
R
O
D
E
P
E
R
N
.
E
.
C
.
2
5
0
.
5
8
.
5
.
G
R
O
U
N
D
E
L
E
C
T
R
O
D
E
C
O
N
D
U
C
T
O
R
F
R
O
M
I
N
V
E
R
T
E
R
T
O
G
R
O
U
N
D
E
L
E
C
T
R
O
D
E
T
O
B
E
M
I
N
I
M
U
M
P
R
O
T
E
C
T
I
O
N
O
F
B
A
R
E
A
R
M
O
R
S
H
E
A
T
H
E
D
C
A
B
L
E
F
O
R
A
L
L
C
O
N
D
U
C
T
O
R
S
I
Z
E
S
.
6
.
A
L
L
G
R
O
U
N
D
C
O
N
N
E
C
T
E
D
T
O
M
A
I
N
S
E
R
V
I
C
E
G
R
O
U
N
D
I
N
M
A
I
N
S
E
R
V
I
C
E
P
A
N
E
L
.
7
.
C
O
N
N
E
C
T
O
R
S
S
H
A
L
L
B
E
P
O
L
A
R
I
S
O
R
E
U
R
O
S
T
R
I
P
I
T
C
O
N
N
E
C
T
O
R
S
.
8
.
I
N
V
E
R
T
E
R
S
H
A
L
L
B
E
P
E
R
S
I
N
G
L
E
L
I
N
E
,
S
E
E
A
T
T
A
C
H
E
D
C
U
T
S
H
E
E
T
.
9
.
I
N
V
E
R
T
E
R
I
S
P
E
R
S
I
N
G
L
E
L
I
N
E
.
1
0
.
A
C
D
I
S
C
O
N
N
E
C
T
S
H
A
L
L
B
E
P
E
R
S
I
N
G
L
E
L
I
N
E
.
1
1
.
E
Q
U
I
P
M
E
N
T
G
R
O
U
N
D
I
N
G
C
O
N
D
U
C
T
O
R
S
O
N
A
C
A
N
D
D
C
S
I
D
E
S
I
Z
E
D
A
C
C
O
R
D
I
N
G
T
O
N
.
E
.
C
.
6
9
0
.
1
2
.
P
O
L
E
O
F
P
V
A
R
R
A
Y
R
E
F
E
R
E
N
C
E
D
T
O
G
R
O
U
N
D
A
T
T
H
E
I
N
V
E
R
T
E
R
I
N
S
I
N
G
L
E
L
I
N
E
.
1
3
.
A
L
L
C
O
N
D
U
C
T
O
R
S
S
H
A
L
L
B
E
6
0
0
V
,
9
0
C
S
T
A
N
D
A
R
D
C
O
P
P
E
R
.
A
L
L
C
O
N
D
U
C
T
O
R
S
I
N
C
O
N
D
U
I
T
S
H
A
L
L
B
E
T
H
W
N
-
2
.
1
4
.
M
A
X
I
M
U
M
D
C
V
O
L
T
A
G
E
D
R
O
P
S
H
A
L
L
B
E
2
.
5
%
1
5
.
A
L
L
C
O
N
D
U
C
T
O
R
S
S
H
A
L
L
B
E
I
N
C
O
N
D
U
I
T
U
N
L
E
S
S
O
T
H
E
R
W
I
S
E
N
O
T
E
D
.
1
6
.
A
L
L
W
O
R
K
T
O
C
O
M
P
L
Y
W
I
T
H
N
E
C
2
0
1
7
C
O
D
E
.
1
7
.
D
C
A
R
R
A
Y
C
O
N
D
U
C
T
O
R
S
A
R
E
T
O
R
E
M
A
I
N
O
U
T
S
I
D
E
O
F
B
U
I
L
D
I
N
G
P
R
I
O
R
T
O
F
U
S
I
B
L
E
C
O
M
B
I
N
E
R
B
O
X
O
R
F
U
S
I
B
L
E
D
C
D
I
S
C
O
N
N
E
C
T
M
E
A
N
S
.
1
8
.
E
X
A
C
T
C
O
N
D
U
I
T
R
U
N
L
O
C
A
T
I
O
N
S
S
U
B
J
E
C
T
T
O
C
H
A
N
G
E
.
1
9
.
3
.
0
P
S
F
M
A
X
(
.
5
P
S
F
F
R
O
M
R
A
C
K
I
N
G
,
2
.
5
P
S
F
F
R
O
M
M
O
D
U
L
E
S
)
D
E
A
D
L
O
A
D
C
O
N
T
R
I
B
U
T
E
D
F
R
O
M
S
O
L
A
R
A
R
R
A
Y
.
2
0
.
A
R
C
F
A
U
L
T
I
N
S
T
A
L
L
E
D
A
T
I
N
V
E
R
T
E
R
O
R
I
N
C
O
M
B
I
N
E
R
B
O
X
.
2
1
.
D
C
G
R
O
U
N
D
F
A
U
L
T
P
R
O
T
E
C
T
I
O
N
I
N
T
E
G
R
A
T
E
D
I
N
I
N
V
E
R
T
E
R
.
2
2
.
P
O
I
N
T
O
F
C
O
N
N
E
C
T
I
O
N
B
R
E
A
K
E
R
T
O
B
E
L
O
C
A
T
E
D
O
P
P
O
S
I
T
E
E
N
D
O
F
B
U
S
B
A
R
F
R
O
M
M
A
I
N
U
N
L
E
S
S
O
T
H
E
R
W
I
S
E
N
O
T
E
D
.
2
3
.
A
N
Y
U
N
D
E
R
G
R
O
U
N
D
W
I
R
I
N
G
M
E
T
H
O
D
S
W
I
L
L
C
O
M
P
L
Y
W
I
T
H
N
E
C
3
0
0
.
5
(
J
)
,
3
0
0
.
7
(
B
)
,
3
5
2
.
4
4
,
A
N
D
O
T
H
E
R
S
E
C
T
I
O
N
S
O
F
C
H
A
P
T
E
R
3
A
S
A
P
P
L
I
C
A
B
L
E
.
2
4
.
A
N
Y
E
X
P
O
S
E
D
P
V
C
C
O
N
D
U
I
T
S
H
A
L
L
C
O
M
P
L
Y
W
I
T
H
N
E
C
3
5
2
.
1
0
2
5
.
A
L
L
P
V
S
Y
S
T
E
M
D
C
C
I
R
C
U
I
T
S
R
U
N
I
N
S
I
D
E
A
B
U
I
L
D
I
N
G
S
H
A
L
L
B
E
C
O
N
T
A
I
N
E
D
I
N
A
M
E
T
A
L
R
A
C
E
W
A
Y
I
N
A
C
C
O
R
D
A
N
C
E
T
O
N
E
C
6
9
0
.
3
1
(
G
)
2
6
.
C
O
M
P
L
I
E
S
W
I
T
H
7
0
5
.
1
2
(
B
)
(
2
)
(
3
)
(
B
)
2
7
.
S
U
P
P
L
Y
S
I
D
E
C
O
N
N
E
C
T
I
O
N
W
I
T
H
L
I
S
T
E
D
I
N
S
U
L
A
T
I
O
N
P
I
E
R
C
I
N
G
C
O
N
N
E
C
T
O
R
S
I
N
A
C
C
O
R
D
A
N
C
E
W
I
T
H
7
0
5
.
1
2
(
A
)
A
N
D
2
3
0
.
8
2
2
8
.
C
O
N
N
E
C
T
I
O
N
A
T
P
A
N
E
L
S
E
C
O
N
D
A
R
Y
S
E
R
V
I
C
E
L
O
C
A
T
I
O
N
2
9
.
C
O
M
P
L
I
E
S
W
I
T
H
7
0
5
.
1
2
(
B
)
(
2
)
(
1
)
(
B
)
ELECTRICAL SINGLE LINE DIAGRAM
1
E
L
E
C
T
R
I
C
A
L
L
I
N
E
D
I
A
G
R
A
M
P
V
-
3
S
C
A
L
E
:
N
T
S
ELECTRICAL
E
Q
U
I
P
M
E
N
T
C
A
L
L
O
U
T
S
7,600W TOTAL SOLAR ARRAY(N)2 Q.PEAK DUO BLK ML-G10+ 400 (400W) PANELS(E)17 Q.PEAK DUO BLK ML-G10+ 400 (400W) PANELSWIRE AND CONDUIT CALLOUTS SOLADECK
M
O
D
E
L
0
7
8
3
-
4
1
J
U
N
C
T
I
O
N
BOX/ROOF P
E
N
E
T
R
A
T
I
O
N
,
(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT/FMC(3) #8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT ABCDEF1 STRING(S) OF 10 MODULES1 STRING(S) OF 9 MODULES CONNECTED IN SERIES @ INVERTERSQUARE D S
A
F
E
T
Y
S
W
I
T
C
H
,
#
D
U
2
2
2
R
B
250 VAC, SI
N
G
L
E
P
H
A
S
E
,
6
0
A
,
N
O
N
-
F
U
S
E
D
NEMA 3R, U
L
,
C
S
A
,
N
O
M
C
E
R
T
I
F
I
E
D
23(E) MAIN SE
R
V
I
C
E
P
A
N
E
L
(W/ (E) 200A
M
A
I
N
B
R
E
A
K
E
R
T
O
P
F
E
D
)
200A, SINGL
E
P
H
A
S
E
,
2
4
0
V
B
A
T
T
E
R
Y
D
C
I
N
P
U
T
M
P
P
T
1
M
P
P
T
2
3
C
(3) #3 AWG THWN-2(1) #8 AWG THWN-2 GND IN 1-1/4" EMT45(2) #14 AWG THWN-2(1) #14 AWG THWN-2 GND IN 3/4" EMT6(2) #8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT/FMC7600V RATED CAT 5 CABLE IN 3/4" EMT
G
S
O
L
A
R
E
D
G
E
-
1
0
K
1
P
S
0
B
-
0
1
B
A
T
T
E
R
Y
U
L
1
6
4
2
&
U
L
1
9
7
2
L
I
S
T
E
D
,
B
R
E
A
K
E
R
P
A
N
E
L
F
O
R
B
A
C
K
U
P
L
O
A
D
S
W
/
N
O
L
O
A
D
S
O
V
E
R
2
0
A
(
W
/
1
0
0
A
M
A
I
N
B
R
E
A
K
E
R
T
O
P
F
E
D
)
H
R
A
P
I
D
S
H
U
T
D
O
W
N
S
W
I
T
C
H
I
J
100AENG 200A F
S
O
L
A
R
E
D
G
E
1
0
K
1
P
S
0
B
-
0
1
B
A
T
T
E
R
Y
7
6
G
4
0
A
1(2)#10 AWG PV/RHW-2 IN FREE AIR(1)#6 AWG BARE COPPER GND IN FREE AIR
L
1
L
2
N
G
D3L1L2NG 4IJG45N100A40APAGE 143 FORCOMPLIANCE WITHNEC 690.12HHOUSE BACKUP LOADS 7LARGEST LOAD IS20A
S
O
L
A
R
E
D
G
E
B
A
C
K
U
P
I
N
T
E
R
F
A
C
E
(
B
I
-
N
U
S
G
N
-
0
2
)
2
0
0
A
,
1
Ø
,
2
4
0
V
BI-DIRECTIO
N
A
L
U
T
I
L
I
T
Y
M
E
T
E
R
200A, SINGL
E
P
H
A
S
E
,
2
4
0
V
6
0
0
V
SOLAREDG
E
S
E
6
0
0
0
H
-
U
S
W
I
T
H
P
R
I
S
M
TECHNOLO
G
Y
I
N
V
E
R
T
E
R
U
N
G
R
O
U
N
D
E
D
,
NEMA 3R, U
L
L
I
S
T
E
D
,
(W/ INTEGR
A
T
E
D
D
C
D
I
S
C
O
N
N
E
C
T
)
WITH INTEG
R
A
T
E
D
G
F
P
,
W
/
I
N
T
E
G
R
A
T
E
D
A
F
P
6.0kW, 240V
A
C
,
S
I
N
G
L
E
P
H
A
S
E
,
2
5
A
,
9
.
7
K
W
H
1
0
0
A
,
S
I
N
G
L
E
P
H
A
S
E
,
2
4
0
V
440W, 1000V
D
C
SOLAREDGE
S
4
4
0
O
P
T
I
M
I
Z
E
R
O
N
E
P
E
R
P
A
N
E
L
_
~
AC DISCON
N
E
C
T
WITHIN 3’ FROM U
T
I
L
I
T
Y
M
E
T
E
R
1
0
M
O
D
U
L
E
S
I
N
S
E
R
I
E
S
B
A
2
1
O
N
E
P
E
R
P
A
N
E
L
9
M
O
D
U
L
E
S
I
N
S
E
R
I
E
S
A
B
O
N
E
P
E
R
P
A
N
E
L
2
1
S
T
R
I
N
G
1
S
T
R
I
N
G
2
S
T
R
I
N
G
1
C
O
N
S
I
S
T
O
F
8
E
X
I
S
T
I
N
G
M
O
D
U
L
E
S
+
2
N
E
W
M
O
D
U
L
E
S
P
l
e
a
s
e
c
a
l
l
f
o
r
r
o
u
g
h
i
n
s
p
e
c
t
i
o
n
o
n
c
e
r
o
o
f
t
o
p
e
q
u
i
p
m
e
n
t
i
s
o
n
s
i
t
e
a
n
d
p
r
i
o
r
t
o
i
n
s
t
a
l
l
a
t
i
o
n
o
n
r
o
o
f
.
T
h
a
n
k
s
ISSUED FOR: PERMIT DATE
03/30/2023
www.bigdogenergy.com
SOLAR PHOTOVOLTAIC SYSTEM
JONATHON EGAN
DESIGNED BY CONTRACTOR INFORMATION
P
V
-
4
1000 WESTWOOD DR.,
REXBURG, ID 83440
BIG DOG RENEWABLE ENERGY
CONTRACTOR LIC #: IDAHO #017916
620 PHEASANT RIDGE DR
CHUBBUCK, ID 83202
208-242-3352 T
208-232-5935 F X__________________
ELECTRICAL CALCULATIONS
ELECTRICAL CALCULATIONSDC CONDUCTOR AMPACITY CALCULATIONS:MAX # OF STRINGS PER SET OF DC CONDUCTORS: 2EXPECTED WIRE TEMP (°C): +22°C Correction: 57°CTEMP CORRECTION PER TABLE 310.16: 0.71OF CURRENT CARRYING CONDUCTORS: 2CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a): 1CIRCUIT CONDUCTOR SIZE: #10 AWGCIRCUIT CONDUCTOR AMPACITY: 30 AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B):1.25 x 1.25 x Isc x # OF STRINGS PER OPTIMIZER: 15 ADERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16:TEMP CORR. PER NEC TABLE 310.16 x CONDUIT FILL CORR. PER NEC310.15(B)(3)(a) x CIRCUIT CONDUCTOR AMPACITY:0.71 x 1 x 30 = 21.30A > 13.93A STRINGS 1 - 2OPERATING VOLTAGE = 1 x 37.13VTOTAL OPERATING CURRENT = 1 x 8.33AMAX PV CONTINUOUS CURRENT PER NEC 690.8(A)(1):1.25 x Isc x # BRANCHES1.25 x 11.14 = 13.93AAC CONDUCTOR AMPACITY CALCULATIONS:# OF INVERTERS: 1EXPECTED WIRE TEMP (°C): 35°CTEMP CORRECTION PER TABLE 310.16: 0.96AWG CIRCUIT CONDUCTOR SIZE: #8# OF CURRENT CARRYING CONDUCTORS: 3CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 1CIRCUIT CONDUCTOR AMPACITY: 50AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B):1.25 x MAX INVERTER OUTPUT CURRENT x # OF INVERTERS1.25 x 25 x 1 = 31.25ADERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16:TEMP CORR. PER NEC TABLE 310.16 x CONDUIT FILL CORR. PER NEC310.15(B)(3)(a) x CIRCUIT CONDUCTOR AMPACITY :0.96 x 1 x 50 = 48.00A > 31.25A <= 40A OCPD
T
O
T
A
L
A
R
R
A
Y
A
C
C
O
N
D
U
C
T
O
R
A
M
P
A
C
I
T
Y
C
A
L
C
U
L
A
T
I
O
N
S
(
F
R
O
M
A
R
R
A
Y
T
O
M
S
P
)
:
#
O
F
I
N
V
E
R
T
E
R
S
:
1
C
I
R
C
U
I
T
C
O
N
D
U
C
T
O
R
S
I
Z
E
:
#
8
#
O
F
C
U
R
R
E
N
T
C
A
R
R
Y
I
N
G
C
O
N
D
U
C
T
O
R
S
:
3
C
O
N
D
U
I
T
F
I
L
L
C
O
R
R
E
C
T
I
O
N
P
E
R
N
E
C
3
1
0
.
1
5
(
B
)
(
2
)
(
a
)
:
1
C
I
R
C
U
I
T
C
O
N
D
U
C
T
O
R
A
M
P
A
C
I
T
Y
:
5
0
A
R
E
Q
U
I
R
E
D
C
I
R
C
U
I
T
C
O
N
D
U
C
T
O
R
A
M
P
A
C
I
T
Y
P
E
R
N
E
C
6
9
0
.
8
(
B
)
:
1
.
2
5
x
M
A
X
I
N
V
E
R
T
E
R
O
U
T
P
U
T
C
U
R
R
E
N
T
x
#
O
F
I
N
V
E
R
T
E
R
S
1
.
2
5
x
2
5
x
1
=
3
1
.
2
5
A
A
M
A
I
N
D
I
S
C
O
N
N
E
C
T
:
2
0
0
A
N
E
W
S
O
L
A
R
S
Y
S
T
E
M
F
U
S
E
/
O
C
P
D
:
4
0
A
MAX PV VOLTAGE & CURRENT CALCULATIONS:RECORD LOW TEMP (°C): -17°CVOLTAGE CORRECTION PER NEC 690.7: 1.23MAX PV SYSTEM VOLTAGE PER NEC 690.7: 45.30 VVcorrection x Voc x # MODULES IN SERIES PER OPTIMIZER 400V
REQUIRED SIGNAGE
ISSUED FOR: PERMIT DATE
03/30/2023
www.bigdogenergy.com
SOLAR PHOTOVOLTAIC SYSTEM
JONATHON EGAN
DESIGNED BY CONTRACTOR INFORMATION
P
V
-
5
1000 WESTWOOD DR.,
REXBURG, ID 83440
BIG DOG RENEWABLE ENERGY
CONTRACTOR LIC #: IDAHO #017916
620 PHEASANT RIDGE DR
CHUBBUCK, ID 83202
208-242-3352 T
208-232-5935 F X__________________
REQUIRED SIGNAGE
2. LABEL FOR SOLAR AC DISCONNECT:
S
Y
S
T
E
M
A
C
V
O
L
T
A
G
E
:
2
4
0
V
T
O
T
A
L
R
A
T
E
D
A
C
A
M
P
S
:
4
0
A
S
Y
S
T
E
M
A
C
V
O
L
T
A
G
E
:
2
4
0
V
3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8"HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITALLETTERS, WHITE ON RED BACKGROUND AND A REFLECTIVE,WEATHER RESISTANT MATERIAL.1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 1/4"HIGH LETTERING PER NEC 690-17.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING: FOLLOWING WORDING:THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.CUSTOMER OWNEDON SITE POWER GENERATIONSYSTEM DISCONNECT
D
I
R
E
C
T
C
U
R
R
E
N
T
P
H
O
T
O
V
O
L
T
A
I
C
S
O
U
R
C
E
S
Y
S
T
E
M
A
C
V
O
L
T
A
G
E
:
2
4
0
V
M
A
X
A
C
C
I
R
C
U
I
T
C
U
R
R
E
N
T
:
2
5
A
M
A
X
D
C
C
U
R
R
E
N
T
P
E
R
O
P
T
I
M
I
Z
E
R
:
1
5
A
8.
T
H
E
F
O
L
L
O
W
I
N
G
S
I
G
N
M
U
S
T
B
E
P
R
O
V
I
D
E
D
O
N
T
H
E
O
U
T
S
I
D
E
(
O
R
W
I
T
H
I
N
3
'
O
F
)
T
H
E
S
E
R
V
I
C
E
P
A
N
E
L
B
O
A
R
D
,
A
S
R
E
Q
U
I
R
E
D
P
E
R
N
E
C
6
9
0
.
5
6
(
C
)
(
1
)
:
R
A
P
I
D
S
H
U
T
D
O
W
N
S
W
I
T
C
H
F
O
R
S
O
L
A
R
P
V
S
Y
S
T
E
M
P
H
O
T
O
V
O
L
T
A
I
C
S
Y
S
T
E
M
E
Q
U
I
P
P
E
D
W
I
T
H
R
A
P
I
D
S
H
U
T
D
O
W
N
A
L
L
S
I
G
N
A
G
E
M
U
S
T
B
E
P
E
R
M
A
N
E
N
T
L
Y
A
T
T
A
C
H
E
D
A
N
D
B
E
W
E
A
T
H
E
R
R
E
S
I
S
T
A
N
T
/
S
U
N
L
I
G
H
T
R
E
S
I
S
T
A
N
T
A
N
D
C
A
N
N
O
T
B
E
H
A
N
D
-
W
R
I
T
T
E
N
.
N
E
C
1
1
0
.
2
1
(
B
)
FIRE DEPARTMENT REQUIRED SIGNAGE4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:5. LABEL INSTALLATION AT INTERCONNECT BREAKER:10
.
S
I
G
N
A
G
E
R
E
Q
U
I
R
E
D
A
T
S
T
R
I
N
G
I
N
V
E
R
T
E
R
P
E
R
N
E
C
6
9
0
.
5
3
:
9.
S
I
G
N
A
G
E
R
E
Q
U
I
R
E
D
A
T
S
E
R
V
I
C
E
P
A
N
E
L
B
O
A
R
D
P
E
R
N
E
C
6
9
0
.
5
4
:
7.
A
T
P
V
D
I
S
C
O
N
N
E
C
T
S
W
I
T
C
H
A
S
R
E
Q
U
I
R
E
D
P
E
R
N
E
C
6
9
0
.
5
6
(
C
)
(
3
)
:
6.
R
E
F
L
E
C
T
I
V
E
P
L
A
C
A
R
D
A
T
S
E
R
V
I
C
E
S
T
A
T
I
N
G
:
"SOLAR AC DISCONNECT"WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALSON BOTH THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION.WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE.
1
0
.
A
T
E
V
E
R
Y
E
N
C
L
O
S
U
R
E
,
E
V
E
R
Y
1
0
’
A
L
O
N
G
C
O
N
D
U
I
T
O
R
M
C
C
A
B
L
E
,
A
N
A
T
E
A
C
H
S
I
D
E
O
F
W
H
E
R
E
T
H
E
C
O
N
D
U
I
T
O
R
C
A
B
L
E
P
A
S
S
E
S
T
H
R
O
U
G
H
A
W
A
L
L
,
F
L
O
O
R
,
O
R
A
N
Y
O
T
H
E
R
P
A
R
T
I
T
I
O
N
.
W
A
R
N
I
N
G
:
P
H
O
T
O
V
O
L
T
A
I
C
P
O
W
E
R
S
O
U
R
C
E
T
H
E
M
A
R
K
I
N
G
S
S
H
A
L
L
B
E
P
E
R
M
A
N
E
N
T
L
Y
A
F
F
I
X
E
D
A
N
D
V
I
S
I
B
L
E
A
F
T
E
R
I
N
S
T
A
L
L
A
T
I
O
N
P
E
R
N
E
C
6
9
0
.
3
1
(
G
)
(
3
-
4
)
.
WARNINGTRI POWER SUPPLY SOURCES:UTILITY GRIDPV SOLAR ELECTRIC SYSTEM ANDBATTERY ENERGY STORAGE SYSTEM