HomeMy WebLinkAboutSITE PLAN - 22-00078 - 341 W 1st N Units 1 & 2 - New DuplexN
E
W
S
71
'
-
8
71
'
-
8
71
'
-
8
71
'
-
8
5/
8
"
5/
8
"
5/
8
"
5/
8
"
81'-1081'-1081'-1081'-10 3/8"3/8"3/8"3/8"
22'22'22'22'
9'9'9'9'
22'22'22'22'
20
'
20
'
20
'
20
'
20'20'20'20'
24
'
24
'
24
'
24
'
341 W 1ST N341 W 1ST N341 W 1ST N341 W 1ST N
REXBURG, IDAHOREXBURG, IDAHOREXBURG, IDAHOREXBURG, IDAHO
5' SETBACK5' SETBACK5' SETBACK5' SETBACK
5' SETBACK5' SETBACK5' SETBACK5' SETBACK
22220000' SETBACK' SETBACK' SETBACK' SETBACK
ACREAGE: 0.235ACREAGE: 0.235ACREAGE: 0.235ACREAGE: 0.235
PARKING AND DRIVEAYPARKING AND DRIVEAYPARKING AND DRIVEAYPARKING AND DRIVEAY
PROPOSEDPROPOSEDPROPOSEDPROPOSED STRUCTURE STRUCTURE STRUCTURE STRUCTURE
: SIDEWALK/PATIO: SIDEWALK/PATIO: SIDEWALK/PATIO: SIDEWALK/PATIO
: : : : DRIVEWAY/ PARKINGDRIVEWAY/ PARKINGDRIVEWAY/ PARKINGDRIVEWAY/ PARKING
: : : : EASEMENTEASEMENTEASEMENTEASEMENT
DRIVEWAY EASEMENTDRIVEWAY EASEMENTDRIVEWAY EASEMENTDRIVEWAY EASEMENT
SIDEWALK/PATIOSIDEWALK/PATIOSIDEWALK/PATIOSIDEWALK/PATIO
SITE PERCENTAGE:SITE PERCENTAGE:SITE PERCENTAGE:SITE PERCENTAGE:
APPROXIMATELY 37.5%APPROXIMATELY 37.5%APPROXIMATELY 37.5%APPROXIMATELY 37.5%
1 SITE PLANSITE PLANSITE PLANSITE PLAN
SCALE: SCALE: SCALE: SCALE: 1" = 10'1" = 10'1" = 10'1" = 10'
SITE PLAN NOTE:SITE PLAN NOTE:SITE PLAN NOTE:SITE PLAN NOTE:
1. SOUTH FORK DESIGN GROUP DOES NOT PROVIDE SURVEYING, CIVIL
ENGINEERING OR GEO TECHNICAL ENGINEERING. IT IS THE RESPONSIBILITY OF THE
OWNER/CONTRACTOR TO ACQUIRE THESE SERVICES IF APPLICABLE.
2. U.N.O. THE SITE PLAN IS BASED ON MEASUREMENTS OBTAINED FROM PUBLIC
RECORD DOCUMENTS OR GIS SYSTEM INFORMATION AND MAY NOT BE EXACT.
3. IT IS THE OWNERS/CONTRACTORS RESPONSIBILITY TO OBTAIN NECESSARY
SURVEY DATA, INCLUDING TOPOGRAPHICAL INFORMATION
4. LOCATION OF UTILITIES SHOULD BE CONFIRMED BY THE CONTRACTOR PRIOR TO
EXCAVATION
5. WHERE SEPTIC AND/OR FRESH WATER WELLS ARE NECESSARY, PERMITS AND
LOCATION SHOULD BE OBTAINED FROM THE AUTHORITY HAVING JURISDICTION
(TYPICALLY HEALTH DEPT)
6. INDICATED LOCATIONS OF SEPTIC, WELL, AND/OR UTILITIES ARE ASSUMED OR
SUGGESTED AND SHOULD BE VERIFIED AND APPROVED BY THE OWNER/CONTRACTOR
AND THE AUTHORITY HAVING JURISDICTION
DR
A
W
N
B
Y
:
CH
K
'
D
B
Y
:
D.
M
.
W.
B
.
S
PL
O
T
D
A
T
E
:
3/
3
/
2
0
2
2
EN
G
I
N
E
E
R
:
R
A
Y
M
C
D
O
U
G
A
L
,
P
E
DE
S
C
R
I
P
T
I
O
N
RE
V
I
S
I
O
N
D
A
T
E
SI
T
E
SH
E
E
T
T
I
T
L
E
:
C-101
PLN# 21-10-024
EI
T
:
J
.
J
.
C
.
12
7
E
.
M
a
i
n
S
t
.
S
u
i
t
e
1
1
1
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
ww
w
.
s
o
u
t
h
f
o
r
k
d
e
s
i
g
n
.
c
o
m
20
8
-
8
5
2
-
6
2
3
6
So
u
t
h
F
o
r
k
D
e
s
i
g
n
G
r
o
u
p
,
L
L
C
KA
R
L
A
&
M
I
K
E
N
E
F
34
1
W
1
S
T
N
RE
X
B
U
R
G
,
I
D
A
H
O
Co
p
y
r
i
g
h
t
2
0
2
2
|
S
o
u
t
h
f
o
r
k
E
n
g
i
n
e
e
r
i
n
g
|
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
.