Loading...
HomeMy WebLinkAboutPLANS - 23-00277 - BYUI Romney - Remodel3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: b y u i d a h o p r o j e c t # : 002294 4/28/2023 G000 COVER SHEET 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set Romney 2023 Remodel Bid Set - 04/28/2023 owner company address 1 salt lake city, ut 84101 (801) 000-0000 contact: architect method studio 360 w aspen ave salt lake city, ut 84101 (801) 532-4422 contact: civil company address 1 salt lake city, ut 84101 (801) 000-0000 contact: structural company address 1 salt lake city, ut 84101 (801) 000-0000 contact: mechanical company address 1 salt lake city, ut 84101 (801) 000-0000 contact: electrical company address 1 salt lake city, ut 84101 (801) 000-0000 contact: MATERIAL LEGEND EARTH (EXISTING) EARTH (BACKFILL) DRAINAGE FILL COMPACTED FILL CONCRETE CAST-IN-PLACE CONCRETE PRECAST BRICK CONCRETE MASONRY UNIT GROUT STEEL ALUMINUM CONTINUOUS WOOD SHEATHING INTERMITTENT WOOD BLOCKING WOOD FINISH HARDBOARD PARTICLE BOARD BATT INSULATION LOOSE FILL INSULATION RIGID INSULATION FIRE SPRAY GYPSUM BOARD ARCHITECTURE SYMBOLS A102 SHEET TYPE DISCIPLINE SHEET NUMBER SEQUENCE ? XX 000x F1 R1 101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES 100' - 0" MAIN LEVEL LEVEL NAME LEVEL ELEVATION AE000 1 Ref 1 Re f 1 Ref 1 Re f AE000 1 Ref 1 Re f 1 Ref 1 Re f SHEET NUMBER POSITION ON SHEET SHEET NUMBER POSITION ON SHEET DRAWING NUMBER VIEW NAME DRAWING SCALE ORIGINAL SOURCE OF DETAIL SIMA1 A526.a SIMA1 A526.a POSITION ON SHEET SHEET NUMBER SHEET NUMBER VIEW DIRECTION POSITION ON SHEET A1 AE101 SIM A1 AE101 SIM A1 AE101 SIM VIEW DIRECTION POSITION ON SHEET SHEET NUMBER ROOM NUMBER ROOM AREA 01A SIGN TYPE SIGN NUMBER VIEW DIRECTION POSITION ON SHEET SHEET NUMBER 1 DELTA MARKER 10' - 0" HEIGHT OF ELEMENT C1 10' - 0" CEILING TYPE CEILING HEIGHT 1 2 A B A1 STARTS AT UPPER LEFT CORNER; NUMBERS ARE VERTICAL GRIDS AND LETTERS ARE HORIZONTAL GRIDS (EXCLUDES LETTERS "I" AND "O") Room name 101 F B W F C P T - 0 1 ? ROOM NAME ROOM NUMBER WALL FINISH BASE FINISH FLOOR FINISH WALL,BASE, OR FLOOR MATERIAL FINISH CODE ARROWS REPRESENT EXTENT OF SCOPE REFER TO FINISH LEGEND WC-01 00.00 ROOM NAME 101 150 SF KEYNOTE TAG CURTAIN WALL TAG DOOR TAG FLOOR TAG ROOF TAG WALL TAGS REVISION CLOUD A1 VIEW NAME 1/8" = 1'-0" (REF: A1/A101) CORE MATERIAL (SEE LEGEND) LAYERS (SEE LEGEND) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) 1 SA6 a SA6 a SEE WALL TYPE SHEET(S) FOR LEGEND ADD ALTERNATE LIST 1. ROLLER WINDOW SHADES IN BIO-CHEMISTRY LAB 272. 2. SNORKELS IN BIO-CHEMISTRY LAB 272, INCLUDING DUCTS TO SNORKELS 3. CONDUIT AND WIRING TO ROOF FROM THE PHYSICS LAB 52 TO AN ANTENNA INSTALLED ON THE ROOF. 4. ACOUSTIC FOAM ON THE WALLS AND CEILING OF THE ACOUSTICS LAB 52B. 5. ALL DEIONIZED WATER SPOUTS/FAUCETS, INCLUDING PIPING TO SPOUTS/FAUCETS. 6. LIGHT FIXTURE RAIL AND ACCORDION ARM IN PHOTO STUDIO 51. 7. ADDITIONAL HAIR LIGHT IN PHOTO STUDIO 51. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: b y u i d a h o p r o j e c t # : 002294 4/28/2023 G001 INDEX, GENERAL NOTES, LEGENDS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set ABBREVIATION SCHEDULE Abbrev.Description 0 # NUMBER OR POUND & AND 2:1 SL 2 HORIZONTAL TO 1 VERTICAL SLOPE @ AT [ CHANNEL ± PLUS MINUS ≤ LESS THAN OR EQUAL TO ≥ GREATER THAN OR EQUAL TO A AB ANCHOR BOLT AC APSHALTIC CONCRETE ACST ACOUSTIC AD AREA DRAIN ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM ARCH ARCHITECTURAL, ARCHITECT, ARCHITECTURE ASPH ASPHALT B B BASELINE B BOTTOM BEJ BRICK EXPANSION JOINT BLDG BUILDING BLK BLOCK BM BEAM BO BOARD BRG BEARING BSMT BASEMENT C C&G CURB & GUTTER CAP CAPACITY CEM CEMENT CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CG CORNER GUARD CIP CAST IN PLACE, CAST IRON PIPE CIR CIRCULATING CJ CONTROL JOINT CL CENTERLINE CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNITS COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CPT CARPET CSK COUNTERSUNK CT CERAMIC TILE CTR CENTER D D DEPTH DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DS DOWNSPOUT DWG DRAWING E E EAST E/P EDGE OF PAVEMENT EA EACH EL ELEVATION ELECT ELECTRICAL ELEV ELEVATOR EMER EMERGENCY EQ EQUAL EQUIP EQUIPMENT EW EACH WAY EWC ELECTRIC WATER COOLER EXIST EXISTING EXP EXPANSION EXP JT EXPANSION JOINT EXT EXTERIOR F F.V. FIELD VERIFY FD FLOOR DRAIN FDN FOUNDATION FE FIRE EXTINGUISHER FFE FINISHED FLOOR ELEVATION FH FIRE HYDRANT FHC FIRE HOSE CABINET FIN FINISH FLR FLOOR FR FRAME FTG FOOTING FXTR FIXTURE G G GROUND GA GA GALV GALVANIZED GL GLASS GR GRADE GRD GROUND GWB GYPSUM WALL BOARD H HB HOSE BIBB HC HANDICAPPED HDW HARDWARE HGT HEIGHT HORZ HORIZONTAL HR HOUR GENERAL NOTES - MISCELLANEOUS 1 THE PROJECT MANUAL, UNDER SEPARATE COVER, IS AN INTEGRAL PART OF THESE CONSTRUCTION DRAWINGS. 2 PLANS, SECTIONS, ELEVATIONS, DETAILS AND DIMENSIONS LABELED "TYPICAL" SHALL APPLY TO ALL SITUATIONS OCCURRING THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY KEYED ON THE DRAWINGS. 3 ALL WORK, MATERIALS, AND METHODS SHALL BE IN CONFORMANCE WITH THE CODES, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT LOCATION. 4 UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING NOT IN CONTRACT (N.I.C.) OR EXISTING, ALL ITEMS, MATERIALS AND INSTALLATION OF SAME ARE PART OF THE CONTRACT AS DEFINED BY THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESSORIES, COMPONENTS AND ASSEMBLIES REQUIRED FOR THE WORK DEPICTED OR SPECIFIED. 5 CONTRACTORS ARE RESPONSIBLE FOR ALL WORK REGARDLESS OF THE LOCATION OF THE INFORMATION ON THE DOCUMENTS. 6 KEEP SITE CLEAN AND CLEAR OF DEBRIS AND IN ORDERLY CONDITION THAT DOES NOT DETRACT FROM THE SURROUNDING SITE AND REPAIR ANY DAMAGE CAUSED BY WORK OF THE CONTRACT. 7 ALL DIMENSIONS ARE TO THE FACE OF METAL OR WOOD STUD FRAMED WALLS AND TO THE FACE OF CONCRETE AND MASONRY WALLS AS SHOWN, UNLESS NOTED OTHERWISE. 8 INSTALL SEALANT AT EXTERIOR SIDE OF ALL JOINTS, SEAMS, CONNECTIONS OR OPENINGS WHICH WOULD ALLOW WATER OR AIR INFILTRATION EXCEPT AS NOTED OTHERWISE. SEALANT COLOR TO MATCH ADJACENT SURFACE. COLOR REQUIRES ARCHITECTS APPROVAL. 9 DOOR OPENINGS IN FRAME CONSTRUCTION WHICH ARE NOT DIMENSIONED ARE EITHER CENTERED IN THE WALL, FACE OF JAMB OR LOCATED 4" FROM THE FACE OF STUD TO THE FINISHED JAMB. 10 ALL SPECIAL ACCESSIBLE FACILITIES SHALL BE IDENTIFIED WITH APPROVED SIGNAGE. 11 THE CONTRACTOR IS RESPONSIBLE FOR PRODUCING A WEATHER TIGHT BUILDING, DETAILS AND OMISSIONS TO DRAWINGS NOTWITHSTANDING. ALL DRAWING CONFLICTS WHICH MAY NOT ALLOW A WEATHERTIGHT CONDITION SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 12 DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. CONTRACTOR SHALL SUBMIT SPECIFIC DISCREPANCIES FOR ARCHITECT REVIEW. 13 PROVIDE FULL METAL BACKING PLATE (16 GAUGE X 6" HIGH SECURED TO 3 STUDS MIN.) OR WOOD BLOCKING AS REQUIRED TO SECURELY ANCHOR ALL WALL MOUNTED EQUIPMENT (CABINETS, TOILET ROOM ACCESSORIES, HARDWARE, ETC.). BLOCKING SHALL PROVIDE A RIGID CONNECTION CAPABLE OF SUPPORTING DESIGN LOADS. PROVIDE A 16 GAUGE X 6" STL. STUD/TRACK SECURED TO 2 STUDS TO SECURELY SUPPORT ALL WALL STOPS (DOOR BUMPER). 14 COORDINATE WITH ALL TRADES, SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, EQUIPMENT PADS OR BASES, AS WELL AS ELECTRIC POWER, WATER, AND DRAIN INSTALLATIONS, BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL PROVIDE COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES' WORK. ANY CONCERNS, SPACE LIMITATIONS, OR STRUCTURAL CONFLICTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. A REASONABLE RESPONSE TIME SHALL BE ALLOWED AS NOTED IN THE SPECIFICATIONS. 15 ALL FLOOR OR WALL OPENINGS REQUIRED FOR PIPES, DUCTS, CONDUITS,ETC. SHALL BE SEALED IN AN APPROVED MANNER. 16 FIRE SPRINKLER DESIGN TO BE DONE BY A CERTIFIED SUB-CONTRACTOR AND WILL REQUIRE APPROVALS BY THE CITY, AND STATE FIRE MARSHALS. APPROVALS BY THE FIRE MARSHAL ARE TO BE OBTAINED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO ARCHITECT. SUBMITTAL TO THE ARCHITECT ALSO INDICATES THAT THE CONTRACTOR HAS REVIEWED AND COORDINATED FIRE-SPRINKLER PIPING LOCATIONS WITH ALL TRADES. 17 ROOMS ENCLOSED WITH RATED WALLS REQUIRE RATED DOORS. ANY DUCTS PASSING THROUGH WALLS REQUIRE FIRE DAMPERS AND OR FIRE/SMOKE DAMPERS. ANY CONDUIT OR PIPING REQUIRES RATED SEALANT AT JOINTS. 18 GENERAL STRUCTURAL NOTES GOVERN TYPICAL CONDITIONS WHETHER OR NOT SPECIFICALLY DETAILED OR NOTED. 19 IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, DATA, AND PHONE RECEPTACLES, SWITCHES, ETC. TO AVOID CASEWORK, DOORS, ETC. 20 THE DRAWINGS AND SPECIFICATIONS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL AND STRUCTURAL DESIGN CONCEPT. THE DI MENSIONS OF THE BUILDING, THE TYPE OF STRUCTURAL, MECHANICAL, ELECTRICAL, AND UTILITY SYSTEMS AND MAJOR ARCHITECTURAL ELEMENTS OF CONSTRUCTION AS "SCOPE" DOCUMENTS. 21 THE DRAWINGS AND SPECIFICATIONS DO NOT NECESSARIL Y INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE WORK. CONTRACTS SHALL BE LET ON THE BASIS OF SUCH DOCUMENTS, WITH THE UNDERSTANDING THAT THE CONTRACTOR IS TO FURNISH ALL ITEMS REQUIRED FOR PROPER COMPLETION OF THE WORK WITHOUT ADJUSTMENT TO CONTRACT PRICE. IT IS INTENDED THAT THE WORK TO BE OF SOUND AND QUALITY CONSTRUCTION AND THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE INCLUSION OF ADEQUATE AMOUNTS TO COVER INSTALLATION OF ALL ITEMS INDICATED, DESCRIBED, OR REASONABLY IMPLIED. DRAWING INDEX GENERAL G000 COVER SHEET G001 INDEX, GENERAL NOTES, LEGENDS G002 CODE ANALYSIS G003 CODE ANALYSIS & PLANS - LEVEL 00 G004 CODE ANALYSIS & PLANS - LEVEL 01 G005 CODE ANALYSIS & PLANS - LEVEL 02 G011 ADA GUIDELINES G015 CODE REQUIRED SIGNAGE & DETAILS ARCHITECTURAL DEMOLITION D100 LEVEL 00 DEMO PLAN D101 LEVEL 01 DEMO PLAN D102 LEVEL 02 DEMO PLAN D130 LEVEL 00 DEMO RCP PLAN D131 LEVEL 01 DEMO RCP PLAN D132 LEVEL 02 DEMO RCP PLAN ARCHITECTURAL A100 LEVEL 00 FLOOR PLAN A101 LEVEL 01 FLOOR PLAN A102 LEVEL 02 FLOOR PLAN A120 LEVEL 00 DIMENSION PLAN A121 LEVEL 01 DIMENSION PLAN A122 LEVEL 02 DIMENSION PLAN A130 LEVEL 00 RCP PLAN A131 LEVEL 01 RCP PLAN A132 LEVEL 02 RCP PLAN A411A ENLARGED PLANS AND INTERIOR ELEVATIONS A411B INTERIOR ELEVATIONS A412 ENLARGED PLANS AND INTERIOR ELEVATIONS A413 ENLARGED PLANS AND INTERIOR ELEVATIONS A414 INTERIOR ELEVATIONS A415 RESTROOM ENLARGED PLANS AND INTERIOR ELEVATIONS A501 WALL ASSEMBLIES - INTERIOR A514 CEILING DETAILS A571 INTERIOR DETAILS A581 CASEWORK DETAILS A601 DOOR & WINDOW TYPES AND SCHEDULE A700 LEVEL 00 FINISH PLANS A701 LEVEL 01 FINISH PLANS A702 LEVEL 02 FINISH PLANS A710 FINISH SCHEDULES, ACCESSORY SCHEDULES A900 LEVEL 00 FURNITURE PLAN A901 LEVEL 01 FURNITURE PLAN A902 LEVEL 02 FURNITURE PLAN A910 EQUIPMENT & FURNITURE PLANS & SCHEDULE A911 EQUIPMENT & FURNITURE PLANS & SCHEDULES ABBREVIATION SCHEDULE Abbrev.Description HW HOT WATER I ID INSIDE DIAMETER IE INVERT ELEVATION INSUL INSULATION INT INTERIOR INTX INTERSECTION INV INVERT J JB JUNCTION BOX JCT JUNCTION JST JOIST JT JOINT L L ANGLE L LENGTH LC LENGTH OF CURVE LDC LEAD COVERED LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LT LIGHT M MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MET METAL MFR MANUFACTURER MH MANHOLE MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTD MOUNTED MTG MOUNTING MULL MULLION MWP MEMBRANE WATERPROOFING N N NORTH NA NOT APPLICABLE NE NORTHEAST NEC NATIONAL ELECTRIC CODE NEUT NEUTRAL NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE NW NIORTHWEST O OA OUTSIDE AIR OA OUTSIDE AIR OC ON CENTER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED OFOI OWNER FURNISHED, OWNER INSTALLED OPP OPPOSITE OVHD OVERHEAD P PI POINT IF INTERSECTION PL PLATE PLAS PLASTER PLYWD PLYWOOD PNL PANEL PNT PAINT PRELIM PRELIMINARY PRESS PRESSURE PRIM PRIMARY PRTN PARTITION PT POINT, POINT OF TANGENT Q QT QUARRY TILE R R RADIUS RA RETURN AIR RB RESILIENT VINYL BASE RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN RECP RECEPTACLE REINF REINFORCEMENT REQD REQUIRED REV REVISION RF ROOF RFLCP REFLECTIVE CEILING PLAN RM ROOM RVT RESILIENT VINYL TILE S S SOUTH SCH SCHEDULE SD STORM DRAIN SE SOUTHEAST SECT SECTION SHT SHEET SIM SIMILIAR SL SLOPE SPEC SPECIFICATION SQ SQUARE STL STEEL SUSP SUSPENDED T T TOP T&B TOP AND BOTTOM TEL TELEPHONE TEMP TEMPORARY TERM TERMINAL THK THICK/THICKNESS THRSLD THRESHOLD TO TOP OF TOS TOP OF STEEL, TOP OF SLAB TOW TOP OF WALL TYP TYPICAL U UNO UNLESS NOTED OTHERWISE V VCT VINYL COMPOSITION TILE VENT VENTILIATING VERT VERTICAL VEST VESTIBULE VWC VINYL WALL COVERING W W WIDTH, WEST W/ WITH W/O WITHOUT WC WATER CLOSET WD WIDTH WT WEIGHT WWF WELDED WIRE FABRIC X X TRANSFORMER MECHANICAL M-001 MECHANICAL SCHEDULES AND SYMBOL LEGEND MD100 LEVEL 01 MECHANICAL DEMOLITION PLAN MD102 LEVEL 02 MECHANICAL DEMOLITION PLAN MD200 LEVEL 00 MECHANICAL PIPING DEMOLITION PLAN MD202 LEVEL 02 MECHANCIAL PIPING DEMOLTION PLAN MH100 LEVEL 00 MECHANICAL REMODEL PLAN MH102 LEVEL 02 MECHANICAL REMODEL PLAN MH501 MECHANICAL DETAILS MH502 MECHANICAL DETAILS MP200 LEVEL 00 MECHANICAL PIPING REMODEL PLAN MP202 LEVEL 02 MECHANICAL PIPING REMODEL PLAN MP501 MECHANICAL PIPING DETAILS FIRE PROTECTION FD100 LEVEL 00 FIRE PROTECTION DEMOLITION PLAN FD101 LEVEL 01 FIRE PROTECTION DEMOLITION PLAN FD102 LEVEL 02 FIRE PROTECTION DEMOLITION PLAN FP100 LEVEL 00 FIRE PROTECTION REMODEL PLAN FP101 LEVEL 01 FIRE PROTECTION REMODEL PLAN FP102 LEVEL 02 FIRE PROTECTION REMODEL PLAN ELECTRICAL EG0.0 ELECTRICAL SYMBOLS & DETAILS ED1.0 LEVEL 00 EXISTING POWER PLAN ED1.1 LEVEL 00 EXISTING LIGHTING PLAN ED1.2 LEVEL 01 EXISTING PLAN ED2.2 LEVEL 02 EXISTING ELECTRICAL PLAN EE1.0 LEVEL 00 LIGHTING PLAN EE2.0 LEVEL 00 ELECTRICAL PLAN EE2.1 LEVEL 01 ELECTRICAL PLAN EE2.2 LEVEL 02 ELECTRICAL PLAN EE3.0 PANEL SCHEDULES STRUCTURAL SE-001 GENERAL NOTES SE-101 LEVEL 01 FRAMING PLAN SE-102 ROOF FRAMING PLAN SE-501 DETAILS PLUMBING P-001 PLUMBING SCHEDULES AND SYMBOL LEGEND PD100 LEVLE 00 PLUMBING DEMOLITION PLAN PD101 LEVLE 01 PLUMBING DEMOLITION PLAN PD102 LEVLE 02 PLUMBING DEMOLITION PLAN PD401 ENLARGED LEVEL 00 PLUMBING DEMOLITION PLAN PD402 ENLARGED PLUMBING DEMOLITION PLANS PL100 LEVEL 00 PLUMBING MODEL PLAN PL101 LEVEL 01 PLUMBING REMODEL PLAN PL102 LEVEL 02 PLUBMING REMODEL PLAN PL401 ENLARGED LEVEL 00 PLUMBING REMODEL PLAN - WASTE & VENT PL402 ENLARGED LEVEL 00 PLUMBING REMODEL PLAN - WATER & GAS PL403 ENLARGED PLUMBING REMODEL PLANS PL404 ENLARGED PLUMBING REMODEL PLANS PL501 PLUMBING DETAILS CODE ANALYSIS APPLICABLE CODES YEAR YEAR INTERNATIONAL BUILDING CODE INTERNATIONAL MECHANICAL CODE INTERNATIONAL PLUMBING CODE INTERNATIONAL FIRE CODE INTERNATIONAL ENERGY CONSERVATION CODE NATIONAL ELECTRICAL CODE UNIFORM CODE FOR BUILDING CONSERVATION ADA ACCESSIBILITY GUIDELINES A. OCCUPANCY AND GROUP: CHANGE IN USE: YES SPECIAL USE AND OCCUPANCY (e.g. HIGH RISE, COVERED MALL): MIXED OCCUPANCY: YES B. SEISMIC DESIGN CATEGORY:DESIGN WIND SPEED (mph): C. TYPE OF CONSTRUCTION (CIRCLE ONE): I A V B I B II A II B III A III B IV HT V A D. FIRE RESISTANCE RATING REQUIREMENTS FOR THE EXTERIOR WALLS BASED ON THE FIRE SEPARATION DISTANCE (IN HOURS): NORTH EAST SOUTH WEST E. MIXED OCCUPANCIES: NON-SEPARATED USES: F. SPRINKLERS: REQUIRED: PROVIDED: TYPE OF SPRINKLER SYSTEM: G. NUMBER OF STORIES: BUILDING HEIGHT: H. ACTUAL AREA (Aa) PER FLOOR (SF, SEE AREA SCHEDULE): I. TABULAR AREA (At): J. AREA MODIFICATIONS: K. FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) L. DESIGN OCCUPANT LOAD: EXIT WIDTH REQUIRED (inches): EXIT WIDTH PROVIDED: M. MINIMUM NUMBER OF REQUIRED PLUMBING FACILITIES: (SEE "PLUMBING CODE CALCULATION" SCHEDULE & "PROVIDED PLUMBING FIXTURE SCHEDULE") FOOTNOTES: 1) IN CASE OF CONFLICT WITH THE U.S. DEPARTMENT OF JUSTICE FEDERAL REGISTERS PARTS I THROUGH V - ADA GUIDELINES AND SPECIFIC REFERENCE TO THE INTERNATIONAL BUILDING CODE ACCESSIBILITY CHAPTERS, THE MORE RESTRICTIVE REQUIREMENT SHALL GOVERN. 2) ADDITIONAL CODE INFORMATION SHALL BE PROVIDED AT THE DISCRETION OF THE BUILDING OFFICIAL FOR COMPLEX BUILDINGS. INCLUDING, BUT NOT LIMITED TO: a) HIGH RISE REQUIREMENTS b) ATRIUMS c) PERFORMANCE BASED CRITERIA d) MEANS OF EGRESS ANALYSIS e) FIRE ASSEMBLY LOCATOR SHEET f) EXTERIOR AND INTERIOR ACCESSIBILITY ROUTE g) FIRE STOPPING, INCLUDING TESTED DESIGN NUMBER NO NO a) Aa = At + (NS x If) c) SUM OF THE RATIO CALCULATIONS FOR MIXED OCCUPANCIES: ACTUAL AREA / ALLOWWABLE AREA ≤ 1 b)If = [F/P - 0.25 ] W/30 ELEMENT HOURS ASSEMBLY LISTING Primary Structural Frame Bearing Walls -Exterior Bearing Walls -Interior Nonbearing Walls/Partitions -Interior Nonbearing Walls/Partitions -Exterior Floor construction and associated secondary members Roof construction and associated secondary members Exterior Doors & Windows Shaft Enclosures Fire Walls Fire Partitions Smoke Partitions Fire Barriers Yes Yes 262" SINGLE OCCUPANCY ONE STORY 2018 2017 2009 2018 2018 2015 2018 C 112 Yes (EXISTING) 3 57' - 6" 0.00 SF 9' - 0" [ 0' / 0' - 0.25 ] 0' / 30 0 + ( 0 x - - - - - - - - - NONE NONE NONE EXISTING NONE 0.00 SF / 0.00 SF = 1310 (EXISTING - INCLUDING OBSERVATORY) (ONLY A PORTION OF LEVLE 1 IS BEING REMODELED - APPROXIMATLEY 4,200 SF REMODEL) UNCHANGED (PLUS OBSERVATORY) 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 G002 CODE ANALYSIS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set OCCUPANT LOAD SCHEDULE - NEW ROOM # ROOM NAME OCCUPANCY USE AREA (SF) LOAD FACTOR OCCUPANT LOAD LEVEL 00 0-H VESTIBULE NON-OCCUPIED - Restrooms/Corridors/Shafts 120 SF 0 0 50 CLASSROOM EDUCATIONAL (Classroom) 744 SF 20 NET 38 51 PHOTO STUDIO EDUCATIONAL (Shops, Vocational) 983 SF 50 NET 20 51A STORAGE MECHANICAL & STORAGE USE 141 SF 300 GROSS 1 51B CHANGING LOCKER ROOM 50 SF 50 GROSS 2 52 PHYSICS LAB EDUCATIONAL (Shops, Vocational) 946 SF 50 NET 19 52A OPTICS LAB EDUCATIONAL (Shops, Vocational) 118 SF 50 NET 3 52B ACOUSTICS STUDIO EDUCATIONAL (Shops, Vocational) 114 SF 50 NET 3 52C STORAGE MECHANICAL & STORAGE USE 163 SF 300 GROSS 1 55 OFFICE BUSINESS AREAS 120 SF 150 GROSS 1 57 OFFICE BUSINESS AREAS 120 SF 150 GROSS 1 59 COMPUTER LAB EDUCATIONAL (Classroom) 908 SF 20 NET 46 59A EQUIP / CHECK OUT EDUCATIONAL (Shops, Vocational)169 SF 50 NET 4 59B STORAGE MECHANICAL & STORAGE USE 121 SF 300 GROSS 1 59C VESTIBULE NON-OCCUPIED - Restrooms/Corridors/Shafts 26 SF 0 0 59D DARK ROOM EDUCATIONAL (Shops, Vocational) 286 SF 50 NET 6 59E FILM EDUCATIONAL (Shops, Vocational) 33 SF 50 NET 1 64 WOMEN'S RM NON-OCCUPIED - Restrooms/Corridors/Shafts 153 SF 0 0 66 MEN'S RM NON-OCCUPIED - Restrooms/Corridors/Shafts 155 SF 0 0 68 CUST RM MECHANICAL & STORAGE USE 47 SF 300 GROSS 1 O-A VESTIBULE NON-OCCUPIED - Restrooms/Corridors/Shafts 145 SF 0 0 O-C HALLWAY NON-OCCUPIED - Restrooms/Corridors/Shafts 1,169 SF 0 0 O-Q PIPE CHASE NON-OCCUPIED - Restrooms/Corridors/Shafts 47 SF 0 0 6,878 SF 148 LEVEL 01 132 WOMEN'S RM NON-OCCUPIED - Restrooms/Corridors/Shafts 131 SF 0 0 134 MEN'S RM NON-OCCUPIED - Restrooms/Corridors/Shafts 133 SF 0 0 136 UNISEX RM NON-OCCUPIED - Restrooms/Corridors/Shafts 47 SF 0 0 158 PHYSICAL GEOLOGY ROOM EDUCATIONAL (Shops, Vocational) 1,104 SF 50 NET 23 1,415 SF 23 LEVEL 02 220 WOMEN'S ROOM NON-OCCUPIED - Restrooms/Corridors/Shafts 132 SF 0 0 226 MEN'S ROOM NON-OCCUPIED - Restrooms/Corridors/Shafts 135 SF 0 0 272 BIO-CHEMISTRY LAB EDUCATIONAL (Shops, Vocational)1,553 SF 50 NET 32 1,819 SF 32 FULL BUILDING OCCUPANCY (FOR REFERENCE) LEVEL OCC. CLEAR OPEN. LEVEL 00 -168 OCC. 34" LEVEL 01 -470 OCC. 94" LEVEL 02 -672 OCC. 135" ALL -1310 OCC. 263" * OCCUPANCY INCLUDED IN THIS SCHEDULE REFLECT REVISED SPACES ONLY. EXISTING SPACES NIC TO REMAIN UNCHANGED 367.49 SF Occ: 2 STORAGE 18 203.92 SF Occ: 2 CUST OFFICE 16 93.46 SF Occ: 1 CUSTODIAL LAUNDRY RM 14 155.06 SF Occ: 0 MEN'S RM 66 153.38 SF Occ: 0 WOMEN'S RM 64 1,063.91 SF Occ: 4 MECHANICAL ROOM 69 2,001.07 SF Occ: 7 MECHANICAL RM 10 144.77 SF Occ: 0 VESTIBULE O-A 74.83 SF Occ: 1 MECH RM 12 1,168.61 SF Occ: 0 HALLWAY O-C 39.98 SF Occ: 1 STORAGE 63 95.91 SF Occ: 0 STAIRWELL O-B 47.38 SF Occ: 0 ELEVATOR O-D 33.51 SF Occ: 1 MECH RM 67 47.38 SF Occ: 1 CUST RM 68 56.50 SF Occ: 0 STAIRWELL 0-F 95.45 SF Occ: 1 STORAGE 20 56.19 SF Occ: 0 ELEVATOR 0-K 123.30 SF Occ: 0 ELEC VAULT 80 118.84 SF Occ: 0 HALLWAY 0-N COMPACT FILL COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E T U N N E L CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE 743.64 SF Occ: 38 CLASSROOM 50 286.12 SF Occ: 6 DARK ROOM 59D 907.94 SF Occ: 46 COMPUTER LAB 59 982.93 SF Occ: 20 PHOTO STUDIO 51 26.11 SF Occ: 0 VESTIBULE 59C 120.23 SF Occ: 1 OFFICE 57 168.63 SF Occ: 4 EQUIP / CHECK OUT 59A 120.83 SF Occ: 1 STORAGE 59B 120.23 SF Occ: 1 OFFICE 55 33.38 SF Occ: 1 FILM 59E 113.99 SF Occ: 3 ACOUSTICS STUDIO 52B 140.75 SF Occ: 1 STORAGE 51A 50.10 SF Occ: 2 CHANGING 51B 120.02 SF Occ: 0 VESTIBULE 0-H 117.92 SF Occ: 3 OPTICS LAB 52A 945.77 SF Occ: 19 PHYSICS LAB 52 163.10 SF Occ: 1 STORAGE 52C FIRE RISER ROOM 569.42 SF Occ: 12 PLANRTARIUM RM 107 88.92 SF Occ: 0 LIGHT TRAP I-Y FE 1 FE 2 CPE 64 FT CPE 65 FT CP E 8 1 F T TD 50FT TD 72 FT TD 4 9 F T CP E 5 6 F T CPE 47 FT OCC. Req. Prov. 19" 216" 95 OCC. Req. Prov. 12.2" 36" 61 OCC. Req. Prov. 2.4" 36" 12 D I A G . D I S T . = 5 0 ' 28' > 15' 4" (1/3 DIAG. DIST.) DIAG. DIST. = 50'40'> 8' 4" (1/3 DIAG. DIST.) DIAG. DIST. = 60' 2 8 ' 7 " > 2 0 ' (1 /3 D I A G . D I S T .) EXISTING TO REMAIN UNCHANGED BUSINESS USE OCCUPANCY 150 GSF PER OCC. CLASSROOM USE OCCUPANCY 20 NET PER OCC. (LAB) USE OCCUPANCY 50 GSF PER OCC. ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT AREAS 300 GSF PER OCC. OCCUPANCY LOAD AND EXIT REQUIREMENTS (table 1004.5) Level 00 a. Business area = 2,155@150 = 15 occ b. Education shops & vocational = 2,469@50 = 50 occ c. Education Classroom area = 1,797@20 = 90 occ d. Storage area = 1,554@300 = 6 occ 161 occ Level 01 (Geology Room) a. Education Classroom area = 1,126@20 = 57 occ Level 02 (Bio Chemistry Lab) a. Education shops & vocational = 1,577@50 = 32 occ Note: The areas where occupancy is determined above is only in areas where there is redesign. All other occupancies in existing areas that are not being redesigned will remain the same. GRAPHIC LEGEND OCC. Req. Prov. 30" DOOR 36" 150 OCC. Req. Prov. 25.5" STAIR 44" 85 REQUIRED AND PROVIDED DOOR OPENING SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS REQUIRED AND PROVIDED STAIR WIDTH SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS FIRE EXTINGUISHER SURFACE MOUNTED ON WALL HOOK; 75' RADIUS FIRE EXTINGUISHER IN RECESSED CABINET; 75' RADIUS COMMON PATH OF EGRESS (CPE) TRAVEL DISTANCE (TD) POINT AT WHICH A CHOICE OF TWO EXITS BECOME AVAILABLE 25 TRAVEL PATH OCCUPANTS & DIRECTION OF TRAVEL NOTES: a. SEE SHEET SERIES A500 FOR ADDITIONAL WALL TYPE INFORMATION AND UL LISTINGS b. SEE G000 SHEET SERIES FOR ADDITIONAL CODE INFORMATION REMOTE POINT FIRE RATING OF OPENING (IN MINUTES) ADDITIONAL INFORMATION PROVIDED IN A600 SERIES FE 1 FE 2 120 1 HOUR RATING 2 HOUR RATING 3 HOUR RATING 1 1 2 1 2 3 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 G003 CODE ANALYSIS & PLANS - LEVEL 00 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 00 CODE PLAN PLANRTARIUM RM 107 LIGHT TRAP I-Y HAZ. STORAGE 167 HAZ. STORAGE 166 ROCK LABORATORY 164 MEN'S T.R. 162 WOMEN'S T.R. 160 PIPE CHASE I-Q HALLWAY 1-T LAB PREP ROOM 161 ELEVATOR 1-M CUST. 147 STAIRWELL 1-P 1,103.85 SF Occ: 23 PHYSICAL GEOLOGY ROOM 158 PHYSICAL SCIENCE DISPLAY ROOM 156 SEISMOGRAPH ROOM 154 RESOURCE ROOM 150A AUTO TUTORIAL ROOM 171 STORAGE 171A LABORATORY RM 179 OFFICE 175 OFFICE 176 OFFICE 180 OFFICE 182 OFFICE 184 STORAGE RM 133 LECTURE HALL 172 SHOP RM 133A PHYSICS CLASSROOM 105 OFFICE 112 OFFICE 114 OFFICE 116 OFFICE 118 OFFICE 118A ADVANCED LAB 126 LECTURE HALL 127 LAB STORAGE RM 126A ADVANCED LAB 128 ADVANCED LAB RM 129 LABORATORY 141 OFFICE 150 OFFICE 148 OFFICE 146 OFFICE 144 WOMEN'S RM 132 MEN'S RM 134 PHYSICS LECTURE HALL 131 LECTURE HALL 145 PREP/STORAGE RM 143 OFFICE 110 OFFICE 186 MINEROLOGY LAB 149 HALLWAY I-N HALLWAY I-L HALLWAY I-G HALLWAY I-K HALLWAY I-F HALLWAY I-W HALLWAY I-D UNISEX RM 136 STORAGE 172A STORAGE 131A VESTIBULE I-A STAIRWELL I-C STAIRWELL I-B OFFICE 142 HALLWAY 1-U STAIRWELL 1-V BDF 138 STAIRWELL 1-S STAIRWELL 1-H STAIRWELL 1-E ELEVATOR 1-J C P E 1 0 9 F T 8 4 3 /8 " 47 5/8" 6 8 3 /4 " 6 8 1 /2 " BUSINESS USE OCCUPANCY 150 GSF PER OCC. CLASSROOM USE OCCUPANCY 20 NET PER OCC. (LAB) USE OCCUPANCY 50 GSF PER OCC. ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT AREAS 300 GSF PER OCC. OCCUPANCY LOAD AND EXIT REQUIREMENTS (table 1004.5) Level 00 a. Business area = 2,155@150 = 15 occ b. Education shops & vocational = 2,469@50 = 50 occ c. Education Classroom area = 1,797@20 = 90 occ d. Storage area = 1,554@300 = 6 occ 161 occ Level 01 (Geology Room) a. Education Classroom area = 1,126@20 = 57 occ Level 02 (Bio Chemistry Lab) a. Education shops & vocational = 1,577@50 = 32 occ Note: The areas where occupancy is determined above is only in areas where there is redesign. All other occupancies in existing areas that are not being redesigned will remain the same. GRAPHIC LEGEND OCC. Req. Prov. 30" DOOR 36" 150 OCC. Req. Prov. 25.5" STAIR 44" 85 REQUIRED AND PROVIDED DOOR OPENING SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS REQUIRED AND PROVIDED STAIR WIDTH SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS FIRE EXTINGUISHER SURFACE MOUNTED ON WALL HOOK; 75' RADIUS FIRE EXTINGUISHER IN RECESSED CABINET; 75' RADIUS COMMON PATH OF EGRESS (CPE) TRAVEL DISTANCE (TD) POINT AT WHICH A CHOICE OF TWO EXITS BECOME AVAILABLE 25 TRAVEL PATH OCCUPANTS & DIRECTION OF TRAVEL NOTES: a. SEE SHEET SERIES A500 FOR ADDITIONAL WALL TYPE INFORMATION AND UL LISTINGS b. SEE G000 SHEET SERIES FOR ADDITIONAL CODE INFORMATION REMOTE POINT FIRE RATING OF OPENING (IN MINUTES) ADDITIONAL INFORMATION PROVIDED IN A600 SERIES FE 1 FE 2 120 1 HOUR RATING 2 HOUR RATING 3 HOUR RATING 1 1 2 1 2 3 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 G004 CODE ANALYSIS & PLANS - LEVEL 01 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 01 CODE PLAN 238.90 SF Occ: 1 INSTRUMENT RM 203A 743.72 SF Occ: 3 CHEMISTRY STOCK RM 213 77.85 SF Occ: 1 OFFICE 213A 578.04 SF Occ: 29 CLASSROOM 270 591.12 SF Occ: 30 CLASSROOM 268 176.21 SF Occ: 0 MEN'S RM 266 169.03 SF Occ: 0 WOMEN'S RM 264 168.23 SF Occ: 2 OFFICE 252 91.19 SF Occ: 1 OFFICE 253 112.74 SF Occ: 1 OFFICE 250 113.69 SF Occ: 1 OFFICE 248 115.58 SF Occ: 1 OFFICE 246 162.37 SF Occ: 2 OFFICE 244 155.24 SF Occ: 2 OFFICE 242 91.02 SF Occ: 1 OFFICE 240 119.78 SF Occ: 1 OFFICE 238 175.90 SF Occ: 2 WORK ROOM 243 115.88 SF Occ: 1 OFFICE 236 115.88 SF Occ: 1 OFFICE 234 104.40 SF Occ: 1 OFFICE 239 101.04 SF Occ: 1 OFFICE 237 131.23 SF Occ: 1 OFFICE 235 127.46 SF Occ: 1 OFFICE 233 119.78 SF Occ: 1 OFFICE 232 808.75 SF Occ: 41 CLASSROOM 255 1,400.29 SF Occ: 71 CLASSROOM 277 111.42 SF Occ: 1 OFFICE 259 120.51 SF Occ: 1 OFFICE 261 120.51 SF Occ: 1 OFFICE 263 122.69 SF Occ: 1 OFFICE 265 134.52 SF Occ: 0 MEN'S ROOM 226 131.91 SF Occ: 0 WOMEN'S ROOM 220 1,852.48 SF Occ: 38 GENERAL CHEM LAB 282 154.74 SF Occ: 1 CHEM STOCK RM 282A 100.38 SF Occ: 1 OFFICE 286 100.03 SF Occ: 1 OFFICE 285 159.31 SF Occ: 2 OFFICE 289 99.34 SF Occ: 1 OFFICE 290 99.39 SF Occ: 1 OFFICE 291 81.91 SF Occ: 1 OFFICE 292 82.69 SF Occ: 1 OFFICE 294 89.46 SF Occ: 1 OFFICE 296 94.79 SF Occ: 1 OFFICE 298 376.59 SF Occ: 8 CHEMISTRY LAB 204 1,151.54 SF Occ: 24 CHEMISTRY LAB 214 1,957.19 SF Occ: 40 CHEMISTRY LAB 210 408.29 SF Occ: 9 CHEMISTRY PREP RM 281 566.79 SF Occ: 29 CLASSROOM 276 71.08 SF Occ: 1 CUST RM 267 106.94 SF Occ: 1 BDF RM 280 54.80 SF Occ: 1 CUST RM 228 226.66 SF Occ: 1 INSTRUMENT RM 203B 692.97 SF Occ: 35 CLASSROOM 229 742.99 SF Occ: 38 CLASSROOM 279 773.91 SF Occ: 39 CLASSROOM 297 775.67 SF Occ: 39 CLASSROOM 299 1,701.03 SF Occ: 35 CHEMISTRY LAB 203 57.66 SF Occ: 1 STORAGE 258 100.28 SF Occ: 1 STORAGE RM 277A 114.50 SF Occ: 1 WORK ROOM 287A 155.95 SF Occ: 2 SEC/ RECEP RM 287 407.04 SF Occ: 0 HALLWAY 2-U 549.72 SF Occ: 0 HALLWAY 2-D 898.24 SF Occ: 0 HALLWAY 2-F 396.45 SF Occ: 0 HALLWAY 2-S 631.22 SF Occ: 0 LOUNGE 2-V 255.18 SF Occ: 0 HALLWAY 2-J 1,320.13 SF Occ: 0 HALLWAY 2-M 483.03 SF Occ: 4 SECRETARY/RECEPTION RM 230 268.74 SF Occ: 0 HALLWAY 2-K 790.30 SF Occ: 40 CLASSROOM 260 786.38 SF Occ: 40 CLASSROOM 262 85.53 SF Occ: 0 HALLWAY 2-L 36.96 SF Occ: 1 CUST STOR 216149.28 SF Occ: 0 STAIRWELL 2-H 57.50 SF Occ: 0 ELEVATOR 2-G148.55 SF Occ: 0 STAIRWELL 2-T 1,431.99 SF Occ: 0 HALLWAY 2-B 191.53 SF Occ: 0 STAIRWELL 2-A 188.96 SF Occ: 0 STAIRWELL 2-C 1,552.91 SF Occ: 32 BIO-CHEMISTRY LAB 272 FE 2 CPE 73 FT TD 74 FT 45" 8 0 1 /2 " 4 1 1 /4 " FE 2 BUSINESS USE OCCUPANCY 150 GSF PER OCC. CLASSROOM USE OCCUPANCY 20 NET PER OCC. (LAB) USE OCCUPANCY 50 GSF PER OCC. ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT AREAS 300 GSF PER OCC. OCCUPANCY LOAD AND EXIT REQUIREMENTS (table 1004.5) Level 00 a. Business area = 2,155@150 = 15 occ b. Education shops & vocational = 2,469@50 = 50 occ c. Education Classroom area = 1,797@20 = 90 occ d. Storage area = 1,554@300 = 6 occ 161 occ Level 01 (Geology Room) a. Education Classroom area = 1,126@20 = 57 occ Level 02 (Bio Chemistry Lab) a. Education shops & vocational = 1,577@50 = 32 occ Note: The areas where occupancy is determined above is only in areas where there is redesign. All other occupancies in existing areas that are not being redesigned will remain the same. GRAPHIC LEGEND OCC. Req. Prov. 30" DOOR 36" 150 OCC. Req. Prov. 25.5" STAIR 44" 85 REQUIRED AND PROVIDED DOOR OPENING SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS REQUIRED AND PROVIDED STAIR WIDTH SIZE (IN INCHES) BASED OFF NUMBER OF EXITING OCCUPANTS FIRE EXTINGUISHER SURFACE MOUNTED ON WALL HOOK; 75' RADIUS FIRE EXTINGUISHER IN RECESSED CABINET; 75' RADIUS COMMON PATH OF EGRESS (CPE) TRAVEL DISTANCE (TD) POINT AT WHICH A CHOICE OF TWO EXITS BECOME AVAILABLE 25 TRAVEL PATH OCCUPANTS & DIRECTION OF TRAVEL NOTES: a. SEE SHEET SERIES A500 FOR ADDITIONAL WALL TYPE INFORMATION AND UL LISTINGS b. SEE G000 SHEET SERIES FOR ADDITIONAL CODE INFORMATION REMOTE POINT FIRE RATING OF OPENING (IN MINUTES) ADDITIONAL INFORMATION PROVIDED IN A600 SERIES FE 1 FE 2 120 1 HOUR RATING 2 HOUR RATING 3 HOUR RATING 1 1 2 1 2 3 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 G005 CODE ANALYSIS & PLANS - LEVEL 02 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 02 CODE PLAN MIRROR SOAP DISPENSER PAPER TOWEL DISPENSER TOILET PAPER HOLDER SANITARY NAPKIN DISPOSAL SANITARY NAPKIN DISPENSER BABY CHANGING STATION TOILET SEAT COVERS DISPENSER WASTE RECEPTACLE FIRE EXTINGUISHER CABINET HAND DRYER TO R E F L E C T I V E SU R F A C E TO D I S P E N S E R TO D I S P E N S E R / H A N D L E TO O P E N , F L A T SU R F A C E O F B E D NOTES: 1. WHERE SHOWN, 48" MAX HEIGHT SHALL BE MEASURED FROM FLOOR TO ANY HIGHEST OPERABLE PART 2. PROVIDE BLOCKING FOR ALL EQUIPMENT PER MANUFACTURER'S WRITTEN INSTRUCTIONS 3 ' - 4 " M A X 3 ' - 6 " 4 ' - 0 " M A X 1 5 " M I N 2 ' - 0 " 2 ' - 6 "4 ' - 0 " M A X 2 ' - 1 0 " 4 ' - 0 " M A X T O T O P O F O P E N I N G 4 ' - 0 " M A X 4 ' - 0 " M A X 4 ' - 0 " TO D I S P E N S E R / H A N D L E 4 ' - 0 " M A X TRASH CHUTE DOOR 1 ' - 2 " 1' - 0" 3 '-2 " M I N 4 ' - 0 " M A X TOWEL BARS L O C K E R C O N T R O L S 1 5 " M I N - 4 8 " M A X T O T O P O F A C C E S S I B L E ACCESSIBLE LOCKER FIRE CABINET CUPS COAT HOOKS TOP LOCKER SHELF: 46" MAX. AFF BOT. LOCKER SHELF: 15" MIN. AFF NON ACCESSIBLE LOCKER 2x4 TOP EDGE MID RAIL 4x4 POSTS 4'-0" O.C. 2x6 CROSS ROOF SUPPORTS 4'-0" O.C. 3/4" CDX PLYWOOD 1/2" CDX PLYWOOD SHEATHING NAILED TO 2x4 RAILS 2x4 MID AND BOTTOM RAIL 2x4 TOP RAIL 2x4 TOP EDGE MID RAIL 8 ' - 5 " 4x4 POSTS 4'-0" O.C. 2x6 CROSS ROOF SUPPORTS 4'-0" O.C. 3/4" CDX PLYWOOD 1/2" CDX PLYWOOD SHEATHING NAILED TO 2x4 RAILS 2x4 MID AND BOTTOM RAIL 2x4 TOP RAIL 4' - 0" 9' - 0" 2 ' - 6 " M I N 4' - 0" MIN 2' - 0"2' - 0" CR PU SH TO OP EN 4 ' - 0 " M A X ELEVATIONPLAN 5' - 7" MIN 5' - 8" MIN 3 ' - 0 " M I N 5 ' - 0 " M I N 1' - 4" MIN 3' - 0" MIN 1' - 4" MIN 2 ' - 0 " M I N 0 ' - 1 0 " M A X OVERLAP OF KNEE AND TOE 5' - 0" MIN 2 ' - 1 " M A X OVERLAP OF KNEE AND TOE 0' - 8" MIN 0 ' - 8 " M I N CIRCULAR TURNING SPACE - NEW BUILDINGS CIRCULAR TURNING SPACE - EXISTING BUILDINGS T-SHAPED TURNING SPACE - NEW BUILDINGS - OPTION 1 5' - 4" MIN 3 ' - 2 " M I N 5 ' - 0 " M I N 0' - 11" MIN 3' - 6" MIN 0' - 11" MIN 1 ' - 1 0 " M I N T-SHAPED TURNING SPACE - NEW BUILDINGS - OPTION 2 5' - 4" MIN 3 ' - 4 " M I N 5 ' - 0 " M I N 1' - 0" MIN 3' - 4" MIN 1' - 0" MIN 1 ' - 8 " M I N T-SHAPED TURNING SPACE - NEW BUILDINGS - OPTION 3 ARM B A S E B A S E ARM T-SHAPED TURNING SPACE - NEW BUILDINGS - OVERLAP UNOBSTRUCTED FORWARD REACH OBSTRUCTED FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH 15 M I N 38 0 48 M A X 12 2 0 48 M A X 12 2 0 44 M A X 11 2 0 >20-25 MAX 510-635 20 MAX 510 (a)(b) 10 MAX 255 12 2 0 48 M A X 15 M I N 38 0 10 MAX 255 12 2 0 48 M A X 34 M A X 86 5 34 M A X 86 5 46 M A X 11 7 0 > 10-24 MAX 255-610 (a)(b) 430 - 635 17 - 25 7 6 0 2 ' - 6 " m i n (b) plan(a) elevation 430 - 635 17 - 25 7 6 0 3 0 m i n (b) planFIG 306.2 TOE CLEARANCE 2 3 0 9 150 6 max (a) elevation FIG 306.3 KNEE CLEARANCE 2 3 0 9 m i n 280 11 min 6 8 5 2 7 m i n SIZE OF CLEAR FLOOR SPACE 2 ' - 6 " M I N EXISTING BLDGS - 48" MIN NEW BLDGS - 4' - 4" MIN 3' - 0" MIN X > 2 ' - 0 " X > 1 ' - 3 " 5' - 0" MIN POSITION OF CLEAR FLOOR SPACE FORWARD POSITION OF CLEAR FLOOR SPACE PARALLEL MANEUVERING CLEARANCE IN AN ALCOVE PARALLEL APPROACH MANEUVERING CLEARANCE IN AN ALCOVE FORWARD APPROACH PUSH SIDE 4' - 10" MIN. MIN. 1' - 0" 12" MIN. IF DOOR HAS LATCH AND CLOSER 12" MIN. IF DOOR HAS LATCH AND CLOSER MIN. 1' - 0" MIN. 2' - 8" 4 ' - 0 " M I N . FRONT APPROACHHINGE APPROACH 5' - 0" MIN. 3 ' - 6 " M I N . LATCH APPROACH SWINGING DOORS SWINGING DOORS 3 ' - 6 " M I N . SWINGING DOORS STANDARD HARDWARE DOOR PROVIDED WITH CLOSER & LATCH 22" MIN.5 ' - 0 " M I N . 4 ' - 0 " M I N . 1' - 6" MIN. 4 ' - 0 " M I N . 4 ' - 0 " M I N . 1' - 0" MIN. 8 " M A X2' - 0" MIN.4 ' - 6 " M I N . 5 ' - 0 " M I N . 3' - 0" MIN. 3' - 6" MIN. 1' - 10" MIN. 3 ' - 6 " M I N . 1' - 6" MIN. 5 ' - 0 " M I N . 8 " M A X 1 2 M A X . 1 /2 " M A X . 1 /4 " 1 /4 " - 1 /2 " 1 2 LEVEL CHANGE IN FLOOR SURFACE CARPET ON FLOOR SURFACES M A X . 0 ' - 0 1 /2 " ALL TRANSITIONS SHALL COMPLY WITH 2009 ICC A117.1 SECTIONS 302 AND 303 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 G011 ADA GUIDELINES 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/2" = 1'-0"D1 TYPICAL MOUNTING HEIGHTS 1/2" = 1'-0"C5 TYPICAL PEDESTRIAN PROTECTION CORRIDOR 1/2" = 1'-0"E6 CARD READER VIEW 3/8" = 1'-0"E1 (ANSI 304) TURNING SPACE 3/8" = 1'-0"C1 (ANSI 308) REACH RANGES 3/8" = 1'-0"A4 (ANSI 604) TOE / KNEE CLEARANCE 3/8" = 1'-0"A1 (ANSI 305) CLEAR FLOOR SPACE 1/4" = 1'-0"B1 (ANSI 404) DOORS AND DOORWAYS 12" = 1'-0"B4 ACCESSIBLE FLOOR TRANSITIONS BRAILLE AREA, TYP 0 ' - 2 " OR AS REQ'D 0' - 8" ± NOTE: -COLOR AS SELECTED BY ARCHITECT -CHARACTER SIZE AND BRAILLE LOCATION PER ANSI A117.1, CH. 7 EXIT SIGN SIGN 6 0 " M A X 4 8 " M I N ACTIVE LEAF INACTIVE LEAF ACTIVE LEAF ACTIVE LEAF SIGN HEIGHT ABOVE THE FLOOR. TACTILE CHARACTERS SHALL BE 48 INCHES MINIMUM ABOVE THE FLOOR. MEASURED TO THE BASELINE OF THE LOWEST TACTILE CHARACTER AND 60 INCHES MAXIMUM ABOVE THE FLOOR. MEASURED TO THE BASELINE OF THE HIGHEST TACTILE CHARACTER. (ICC/ANSI 703.3.10) SIGN LOCATION. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR. THE SIGN SHALL BE ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF. THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAVES. THE SIGN SHALL BE TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE OF A SINGLE DOOR, OR TO THE RIGHT SIDE OF DOUBLE DOORS. SIGNS SHALL BE ON THE NEAREST ADJACENT WALL. SIGNS SHALL BE ON THE NEAREST SHALL BE LOCATED SO THAT A CLEAR FLOOR AREA 18 INCHES MINIMUM BUY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF THE ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. (ICC/ANSI 703.311) SIGNAGE LOCATIONS WALL CONSTRUCTION ACCESSORY MOUNTED OVER FINISHED WALL GYPSUM BOARD NOTE: 1. TYPICAL BLOCKING REQUIRED BEHIND WALL MOUNTED ACCESSORIES AND EQUIPMENT (OPTION 1) 20 GA x 6" FLAT STEEL BLOCKING. ATTACH W SELF TAPPING PAN HEAD SCREWS (OPTION 3) SISTER 16 GA. STL. STUD ATTACH FIXTURE TO SISTER STUD W/ SELF TAPPING SCREWS OR ANCHORS (OPTION 2) INLAID FIRE RETARDANT WOOD BLOCKING (COMPLY WITH IBC 2006 2303.2) STUDS SHOWN @ 16" O.C. SEE WALL TYPES FOUNTAIN 20 GA x 6" FLAT STEEL BLOCKING 20 GA x 6" FLAT STEEL BLOCKING 16 GA SUPPORT STUD FOR STL. ANGLE BRACING WATER COOLER/ FOUNTAIN PROVIDE FULL VERTICAL BLOCKING AT CENTERLINE OF URINAL NAPKIN TAMPON HAND DRYER 20 GA x 6" FLAT STEEL BLOCKING TYPICAL BLOCKING DETAILS 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 G015 CODE REQUIRED SIGNAGE & DETAILS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 STORAGE 18 CUST OFFICE 16 CUSTODIAL LAUNDRY RM 14 MEN'S RM 66 WOMEN'S RM 64 MECHANICAL ROOM 69 MECHANICAL RM 10 VESTIBULE O-A MECH RM 12 HALLWAY O-C STORAGE 63 STAIRWELL O-B PIPE CHASE O-Q ELEVATOR O-D MECH RM 67 STAIRWELL 0-F STORAGE 20 ELEVATOR 0-K ELEC VAULT 80 HALLWAY 0-N COMPACT FILL COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E T U N N E L CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE 02.01 02.06 02.0202.02 02.02 02.03 02.04 02.06 02.06 02.07 02.08 02.08 02.09 02.10 02.11 02.12 02.13 02.14 02.15 02.15 02.16 02.16 02.17 02.1802.18 02.19 02.19 02.20 02.20 02.05 02.2102.21 02.21 02.21 02.21 TYP 02.21 02.21 02.16 02.16 02.21 02.22 02.06 02.06 02.46 02.49 OFFICE WORK RM LAB OFFICE STUDIO STOR STORAGE B ROOM C ROOM D ROOM E ROOM F ROOM G ROOM K ROOM H ROOM PHOTO STUDIO RMCONFERENCE ROOM OFFICE BLACK AND WHITE PRINTING COMMON PHOTO LAB DRESS RM OFFICE OFFICE HALLWAY LIGHT TRAP HALLWAY/STAIRWELL A BOOTH B BOOTH C BOOTH D BOOTH E BOOTH CUST EXISTING WALLS TO REMAIN LEGEND INTERIOR PARTITION STUD AND GYPSUM BOARD WALLS AND/OR DEMOUNTABLE PARTITIONS, TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED REMOVE EXISTING FLOORING AND PREP FOR FLOOR FOR NEW FLOORING. RE: FINISH PLANS FOR NEW FLOORING. INTERIOR PARTITION DACMU/MASONRY WALLS TO BE DEMOLISHED - PROTECT FLOORS AND SURROUNDING AREAS FROM DAMAGE AREAS THAT ARE N.I.C. SAWCUT AND REMOVE 2'-6" WIDE SECTIONS OF EXISTING CONCRETE AS HATCHED AND INDICATED FOR NEW ELECTRICAL AND PLUMBING. RE: ELECTRICAL AND PLUBMING PLANS FOR COORDINATION. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 D100 LEVEL 00 DEMO PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set1/8" = 1'-0"A1 LEVEL 00 DEMOLITION PLAN GENERAL NOTES - DEMO 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS 2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW CONSTRUCTION 3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION 4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION 5 GENERAL CONTRACTOR SHALL PROVIDE A 6 MIL POLYETHYLENE DUST BARRIER FROM FLOOR TO DECK ABOVE TO ENSURE THAT ALL CORRIDORS OUTSIDE OF CONSTRUCTION AREA ARE KEPT CLEAN AND CLEAR OF DEBRIS AND OBSTRUCTIONS AT ALL TIMES. DUST BARRIER SHALL BE SEALED AIR TIGHT IN ALL PHASED AREAS OF CONSTRUCTION 6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC... 7 GENERAL CONTRACTOR TO PREVENT WATER BUILD-UP AND/OR DAMAGE FOUNDATIONS ON THE CONSTRUCTION SITE OR ADJACENT AREAS 8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303) 9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION 10 ALL EXISTING FURNITURE WILL BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 11 EXISTING ITEMS ON WALLS, SUCH AS CLOCKS, PAPER TOWEL DISPENSERS, WHITE BOARDS, TVS, COAT RACKS, ETC. TO BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 12 ALL EXISTING CMU WALLS HAVE EXISTING THICKENED SLABS UNDERNEATH THEM. BE AWARE WHEN CUTTING NEW TRENCHES FOR PLUMBING AND UNDERGROUND POWER. 13 ADDITIONAL INTERIOR WALLS AND OTHER ITEMS NOT GRAPHICALLY REPRESENTED ON THIS SHEET MAY REQURIE DEMOLITION, CONDUCT A SITE SURVEY TO DETERMINE THE FULL EXTENT OF INTERIOR DEMOLITION WORK. 14 NOTE: BYUI - IT IS CURRENTLY THE PLAN THAT EVERYTHING THAT IS DASHED IN RED WILL BE DEMOLISHED AND REMOVED. IF THERE IS ANYTHING THAT NEEDS TO BE RE-USED OR SAVED, PLEASE LET METHOD STUDIO KNOW. KEYED NOTES 02.01 SAW CUT OPENING IN EXISTING CMU FOR NEW DOORS. RE: FLOOR PLANS, DOOR SCHEDULE, AND STRUCTURAL DRAWINGS FOR NEW OPENING. 02.02 REMOVE EXISTING TECH STATION, PROJECTOR, PROJECTOR SCREEN, AND SPEAKERS. RETURN TO OWNER 02.03 SALVAGE EXISTING COAT RACKS FOR REINSTALLATION BY CONTRACTOR IN NEW OFFICES 02.04 EXISTING STRUCTURAL CMU WALL TO REMAIN, RE: STRUCTURAL FOR REINFORCEMENT TO NEW OPENINGS. 02.05 REMOVE AND DISPOSE OF EXISTING FIRE CABINET. RE: FLOOR PLANS AND ELEVATIONS FOR NEW CABINET. 02.06 SAWCUT AND REMOVE 2'-6" WIDE SECTIONS OF EXISTING CONCRETE AS HATCHED AND INDICATED FOR NEW ELECTRICAL AND PLUMBING. RE: ELECTRICAL AND PLUBMING PLANS FOR COORDINATION. 02.07 REMOVE EXISTING FIRE CABINET. PATCH AND REPAIR TO MATCH EXISTING WALL. 02.08 REPLACE DOOR AND DOOR HARDWARE. EXISTING HM FRAME TO REMAIN AND REVISED AND AND REPAIRED AS NEEDED FOR NEW HARDWARE. RE: FLOOR PLAN, DOOR SCHEDULE AND HARDWARE SPECIFICATIONS. 02.09 REMOVE EXISTING RECESSED CYCLOROMA CURVED WALL. PATCH AND REPAIR FLOORING FOR NEW FLOORING FINISH. 02.10 REMOVE AND DISPOSE OF EXISTING LOCKERS. 02.11 REMOVE EXISTING DOUBLE DOORS AND INFILL WITH CMU WALL TO MAINTAIN 2 HOUR RATING OF MECHANICAL ROOM AND SHAFT WITHIN THE ROOM. 02.12 REMOVE EXISTING HOSE REAL CABINET AND INFILL WITH CMU WALL TO MAINTAIN 2 HOUR RATING OF MECHANICAL ROOM AND SHAFT. 02.13 REMOVE AND RELOCATE CUSTODIAL CLOSET. RE: FLOOR PLAN. 02.14 CAREFULLY REMOVE STRUCTURAL CMU WALL PER STRUCTURAL DRAWINGS. 02.15 SAW CUT MASONRY TO FLOOR DECK. PREP FOR NEW FINISH. RE: FINISH PLANS 02.16 REMOVE AND DISPOSE OF PHOTO PROCESSING SINKS, TYPICAL. 02.17 EXISTING DRYING RACKS TO BE REMOVED AND RETURNED TO OWNER. 02.18 EXISTING FLOOR DRAINS TO REMAIN. RE: PLUBMING. 02.19 EXISTING FLOOR DRAIN TO BE CAPPED AND FLOOR LEVELED AND PREPPED FOR NEW FINISHED FLOOR. RE: FINISH PLANS. 02.20 DEMO EXISTING ELECTRICAL PANELS, RE: ELECTRICAL. 02.21 REMOVE AND DISPOSE OF EXISTING COUNTERTOPS AND CABINETRY. 02.22 EXISTING WALL TILE TO REMAIN AND PROTECTED DURING CONSTRUCTION 02.46 REMOVE FLOOR BOX. PATCH AND REPAIR. RE: ELECTRICAL. 02.49 REMOVE AND SALVAGE CURTAINS AND CEILING TRACKS FOR RE-USE. A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 PLANRTARIUM RM 107 LIGHT TRAP I-Y HAZ. STORAGE 167 HAZ. STORAGE 166 ROCK LABORATORY 164 MEN'S T.R. 162 WOMEN'S T.R. 160 PIPE CHASE I-Q HALLWAY 1-T LAB PREP ROOM 161 ELEVATOR 1-M CUST. 147 STAIRWELL 1-P PHYSICAL GEOLOGY ROOM 158 PHYSICAL SCIENCE DISPLAY ROOM 156 SEISMOGRAPH ROOM 154 RESOURCE ROOM 150A AUTO TUTORIAL ROOM 171 STORAGE 171A LABORATORY RM 179 OFFICE 175 OFFICE 176 OFFICE 180 OFFICE 182 OFFICE 184 STORAGE RM 133 LECTURE HALL 172 SHOP RM 133A PHYSICS CLASSROOM 105 OFFICE 112 OFFICE 114 OFFICE 116 OFFICE 118 OFFICE 118A ADVANCED LAB 126 LECTURE HALL 127 LAB STORAGE RM 126A ADVANCED LAB 128 ADVANCED LAB RM 129 LABORATORY 141 OFFICE 150 OFFICE 148 OFFICE 146 OFFICE 144 WOMEN'S RM 132 MEN'S RM 134 PHYSICS LECTURE HALL 131 LECTURE HALL 145 PREP/STORAGE RM 143 OFFICE 110 OFFICE 186 MINEROLOGY LAB 149 HALLWAY I-N HALLWAY I-L HALLWAY I-G HALLWAY I-K HALLWAY I-F HALLWAY I-W HALLWAY I-D UNISEX RM 136 STORAGE 172A STORAGE 131A VESTIBULE I-A STAIRWELL I-C STAIRWELL I-B OFFICE 142 HALLWAY 1-U STAIRWELL 1-V BDF 138 STAIRWELL 1-S STAIRWELL 1-H STAIRWELL 1-E ELEVATOR 1-J 02.2402.2402.24 02.23 TYP 02.23 TYP02.23 TYP 02.25 02.25 02.25 02.21 02.21 02.26 TYP TYP 02.27 02.30 TYP 02.29 02.28 02.52 02.52 EXISTING WALLS TO REMAIN LEGEND INTERIOR PARTITION STUD AND GYPSUM BOARD WALLS AND/OR DEMOUNTABLE PARTITIONS, TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED REMOVE EXISTING FLOORING AND PREP FOR FLOOR FOR NEW FLOORING. RE: FINISH PLANS FOR NEW FLOORING. INTERIOR PARTITION DACMU/MASONRY WALLS TO BE DEMOLISHED - PROTECT FLOORS AND SURROUNDING AREAS FROM DAMAGE AREAS THAT ARE N.I.C. SAWCUT AND REMOVE 2'-6" WIDE SECTIONS OF EXISTING CONCRETE AS HATCHED AND INDICATED FOR NEW ELECTRICAL AND PLUMBING. RE: ELECTRICAL AND PLUBMING PLANS FOR COORDINATION. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 D101 LEVEL 01 DEMO PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 01 DEMOLITION PLAN GENERAL NOTES - DEMO 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS 2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW CONSTRUCTION 3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION 4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION 5 GENERAL CONTRACTOR SHALL PROVIDE A 6 MIL POLYETHYLENE DUST BARRIER FROM FLOOR TO DECK ABOVE TO ENSURE THAT ALL CORRIDORS OUTSIDE OF CONSTRUCTION AREA ARE KEPT CLEAN AND CLEAR OF DEBRIS AND OBSTRUCTIONS AT ALL TIMES. DUST BARRIER SHALL BE SEALED AIR TIGHT IN ALL PHASED AREAS OF CONSTRUCTION 6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC... 7 GENERAL CONTRACTOR TO PREVENT WATER BUILD-UP AND/OR DAMAGE FOUNDATIONS ON THE CONSTRUCTION SITE OR ADJACENT AREAS 8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303) 9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION 10 ALL EXISTING FURNITURE WILL BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 11 EXISTING ITEMS ON WALLS, SUCH AS CLOCKS, PAPER TOWEL DISPENSERS, WHITE BOARDS, TVS, COAT RACKS, ETC. TO BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 12 ALL EXISTING CMU WALLS HAVE EXISTING THICKENED SLABS UNDERNEATH THEM. BE AWARE WHEN CUTTING NEW TRENCHES FOR PLUMBING AND UNDERGROUND POWER. 13 ADDITIONAL INTERIOR WALLS AND OTHER ITEMS NOT GRAPHICALLY REPRESENTED ON THIS SHEET MAY REQURIE DEMOLITION, CONDUCT A SITE SURVEY TO DETERMINE THE FULL EXTENT OF INTERIOR DEMOLITION WORK. 14 NOTE: BYUI - IT IS CURRENTLY THE PLAN THAT EVERYTHING THAT IS DASHED IN RED WILL BE DEMOLISHED AND REMOVED. IF THERE IS ANYTHING THAT NEEDS TO BE RE-USED OR SAVED, PLEASE LET METHOD STUDIO KNOW. KEYED NOTES 02.21 REMOVE AND DISPOSE OF EXISTING COUNTERTOPS AND CABINETRY. 02.23 REMOVE ALL WALL TILE WITHIN RESTROOM.PREP WALLS FOR NEW FINISH. RE: FLOOR AND FINISH PLANS FOR NEW WALL FINISH. 02.24 REPLACE ALL PLUMBING FIXTURES, PARTITIONS, DISPENSERS, MIRRORS, GRAB BARS, ETC. RE: ENLARGED FLOOR PLANS AND PLUMBING DRAWINGS. 02.25 PARTIAL DEMO EXISTING WALL AS NEED TO REPLACE PLUMBING AND INSULATION IN WALLS. RE: PLUMBING. 02.26 RETURN CHAIRS TO OWNER FOR RE-USE. 02.27 EXISTING UPPER CABINETS TO REMAIN AND TO BE PROTECTED DURING CONSTRUCTION. 02.28 EXISTING PAPER TOWEL DISPENSER TO REMAIN AND TO BE PROTECTED DURING CONSTRUCTION. 02.29 SINK, FAUCET AND DEIONIZED WATER FAUCET TO BE DEMOLISHED AND REPLACED. RE: PLUMBING 02.30 EXISTING VCT FLOORING TO REMIAN AND TO BE PROTECTED DURING CONSTRUCTION. CLEAN AND RESTORE EXISTING VCT THAT IS UNDER THE CASEWORK TO BE REMOVED. IF VCT CANNOT BE CLEANED AND RESTORED, REPLACE VCT PER FINISH SCHEDULE. 02.52 EXISTING CASEWORK TO REMAIN. A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 INSTRUMENT RM 203A CHEMISTRY STOCK RM 213 OFFICE 213A CLASSROOM 270 CLASSROOM 268 MEN'S RM 266 WOMEN'S RM 264 OFFICE 252 OFFICE 253 OFFICE 250 OFFICE 248 OFFICE 246 OFFICE 244 OFFICE 242 OFFICE 240 OFFICE 238 WORK ROOM 243 OFFICE 236 OFFICE 234 OFFICE 239 OFFICE 237 OFFICE 235 OFFICE 233 OFFICE 232 CLASSROOM 255 CLASSROOM 277 OFFICE 259 OFFICE 261 OFFICE 263 OFFICE 265 MEN'S ROOM 226 WOMEN'S ROOM 220 GENERAL CHEM LAB 282 CHEM STOCK RM 282A OFFICE 286 OFFICE 285 OFFICE 289 OFFICE 290 OFFICE 291 OFFICE 292 OFFICE 294 OFFICE 296 OFFICE 298 CHEMISTRY LAB 204 CHEMISTRY LAB 214 CHEMISTRY LAB 210 CHEMISTRY PREP RM 281 CLASSROOM 276 CUST RM 267 BDF RM 280 CUST RM 228 INSTRUMENT RM 203B CLASSROOM 229 CLASSROOM 279 CLASSROOM 297 CLASSROOM 299 CHEMISTRY LAB 203 STORAGE 258 STORAGE RM 277A WORK ROOM 287A SEC/ RECEP RM 287 HALLWAY 2-U HALLWAY 2-D HALLWAY 2-F HALLWAY 2-S LOUNGE 2-V HALLWAY 2-J HALLWAY 2-M SECRETARY/RECEPTION RM 230 HALLWAY 2-K CLASSROOM 260 CLASSROOM 262 HALLWAY 2-L CUST STOR 216 STAIRWELL 2-HELEVATOR 2-G STAIRWELL 2-T HALLWAY 2-B STAIRWELL 2-A STAIRWELL 2-C 02.24 02.25 02.23 TYP 02.24 02.25 02.23 02.25 TYP 02.31 02.32 02.33 02.33 02.34 02.35 02.36 02.45 02.37 02.38 02.39 02.40 02.40 02.41 02.41 02.41 02.42 02.43 02.44 02.55 02.55 02.21 21.03 ADVANCED PHYSICS LAB CHEM LAB RM OFFICE EXISTING WALLS TO REMAIN LEGEND INTERIOR PARTITION STUD AND GYPSUM BOARD WALLS AND/OR DEMOUNTABLE PARTITIONS, TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED REMOVE EXISTING FLOORING AND PREP FOR FLOOR FOR NEW FLOORING. RE: FINISH PLANS FOR NEW FLOORING. INTERIOR PARTITION DACMU/MASONRY WALLS TO BE DEMOLISHED - PROTECT FLOORS AND SURROUNDING AREAS FROM DAMAGE AREAS THAT ARE N.I.C. SAWCUT AND REMOVE 2'-6" WIDE SECTIONS OF EXISTING CONCRETE AS HATCHED AND INDICATED FOR NEW ELECTRICAL AND PLUMBING. RE: ELECTRICAL AND PLUBMING PLANS FOR COORDINATION. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 D102 LEVEL 02 DEMO PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 02 DEMOLITION PLAN GENERAL NOTES - DEMO 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS 2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW CONSTRUCTION 3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION 4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION 5 GENERAL CONTRACTOR SHALL PROVIDE A 6 MIL POLYETHYLENE DUST BARRIER FROM FLOOR TO DECK ABOVE TO ENSURE THAT ALL CORRIDORS OUTSIDE OF CONSTRUCTION AREA ARE KEPT CLEAN AND CLEAR OF DEBRIS AND OBSTRUCTIONS AT ALL TIMES. DUST BARRIER SHALL BE SEALED AIR TIGHT IN ALL PHASED AREAS OF CONSTRUCTION 6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC... 7 GENERAL CONTRACTOR TO PREVENT WATER BUILD-UP AND/OR DAMAGE FOUNDATIONS ON THE CONSTRUCTION SITE OR ADJACENT AREAS 8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303) 9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION 10 ALL EXISTING FURNITURE WILL BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 11 EXISTING ITEMS ON WALLS, SUCH AS CLOCKS, PAPER TOWEL DISPENSERS, WHITE BOARDS, TVS, COAT RACKS, ETC. TO BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 12 ALL EXISTING CMU WALLS HAVE EXISTING THICKENED SLABS UNDERNEATH THEM. BE AWARE WHEN CUTTING NEW TRENCHES FOR PLUMBING AND UNDERGROUND POWER. 13 ADDITIONAL INTERIOR WALLS AND OTHER ITEMS NOT GRAPHICALLY REPRESENTED ON THIS SHEET MAY REQURIE DEMOLITION, CONDUCT A SITE SURVEY TO DETERMINE THE FULL EXTENT OF INTERIOR DEMOLITION WORK. 14 NOTE: BYUI - IT IS CURRENTLY THE PLAN THAT EVERYTHING THAT IS DASHED IN RED WILL BE DEMOLISHED AND REMOVED. IF THERE IS ANYTHING THAT NEEDS TO BE RE-USED OR SAVED, PLEASE LET METHOD STUDIO KNOW. KEYED NOTES 02.21 REMOVE AND DISPOSE OF EXISTING COUNTERTOPS AND CABINETRY. 02.23 REMOVE ALL WALL TILE WITHIN RESTROOM.PREP WALLS FOR NEW FINISH. RE: FLOOR AND FINISH PLANS FOR NEW WALL FINISH. 02.24 REPLACE ALL PLUMBING FIXTURES, PARTITIONS, DISPENSERS, MIRRORS, GRAB BARS, ETC. RE: ENLARGED FLOOR PLANS AND PLUMBING DRAWINGS. 02.25 PARTIAL DEMO EXISTING WALL AS NEED TO REPLACE PLUMBING AND INSULATION IN WALLS. RE: PLUMBING. 02.31 REMOVE AND RETURN EXISTING HOOD AND EQUIPMENT TO OWNER. 02.32 REMOVE EXTERIOR FUROUT WALL AND BLACK COVERING ON EXISTING WINDOW. PREP FOR WINDOW SILL AND NEW FINISHES. RE: FLOOR AND FINISH PLAN. 02.33 REMOVE AND RETURN EXISTING SHELVING TO OWNERS. 02.34 REMOVE EXISTING HOSE REAL CABINET AND INFILL DRYWALL, PATCH AND PAINT TO MATCH EXISTING ADJACENT WALL. 02.35 DEMO EXISTING WALL TILE. PATCH AND REPAIR WALL FOR NEW FINISHES. SEE FINISH PLAN. 02.36 REMOVE GYP BOARD AS NEEDED TO PROVIDE BLOCKING AS NEEDED FOR WHITE BOARD, TANK SUPPORT AND TECH STATION. 02.37 PROVIDE OPENING IN EXISTING WALL FOR A NEW DOOR. RE: FLOOR PLANS AND DOOR SCHEDULE. 02.38 REMOVE AND DISPOSE OF EXISTING SINK. REMOVE EXISTING SOLID SURFACE COUNTER TOP TO NEAREST SEAM AND PREP FOR REPLACEMENT. 02.39 REMOVE AND DISPOSE OF EXISTING CUP SINK. CUT HOLE FOR NEW SINK IN EXISTING SOLID SURFACE. COORDINATE WITH NEW SINK DIMENSIONS. RE: PLUMBING. 02.40 EXISTING AIR AND GAS LINES TO REMAIN. 02.41 EXISTING CUP SINK AND FAUCET TO REMAIN. 02.42 EXISTING COUNTERTOP AND UNDERCOUNTER CABINETS TO REMAIN. 02.43 EXISTING UPPER SHELVING TO REMAIN. 02.44 EXISTING FUME HOODS TO BE RELOCATED TO ROOM 272. RE: MECHANICAL AND FLOOR PLAN. 02.45 REMOVE, PROTECT AND RE-USE EXISTING DOOR AND FRAME FOR NEW DOOR LOCATION. 02.55 REMOVE EXISTING DOOR. 21.03 SALVAGE FIRE BLANKET AND FIRE EXTINGUISHER FOR REUSE A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 COMPACT FILL COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E T U N N E L CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE 02.02 02.51 02.51 02.48 02.50 02.49 02.51 OFFICE WORK RM LAB OFFICE STUDIO STOR STORAGE B ROOM C ROOM D ROOM E ROOM F ROOM G ROOM K ROOM H ROOM PHOTO STUDIO RMCONFERENCE ROOM OFFICE BLACK AND WHITE PRINTING COMMON PHOTO LAB DRESS RM OFFICE OFFICE HALLWAY LIGHT TRAP HALLWAY/STAIRWELL A BOOTH B BOOTH C BOOTH D BOOTH E BOOTH CUST MECHANICAL ROOM CUST RM MECH RM ELEVATOR VESTIBULE HALLWAY WOMEN'S RM PIPE CHASE MEN'S RM HALLWAY EXISTING WALLS TO REMAIN LEGEND INTERIOR PARTITION STUD AND GYPSUM BOARD WALLS AND/OR DEMOUNTABLE PARTITIONS, TO BE DEMOLISHED ACT CEILING TO BE DEMOLISHED INTERIOR PARTITION NON-REINFORCED CMU/MASONRY WALLS TO BE DEMOLISHED - PROTECT FLOORS AND SURROUNDING AREAS FROM DAMAGE N.I.C. GYP. BOARD CEILING TO BE DEMOLISHED 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 D130 LEVEL 00 DEMO RCP PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 00 REFLECTED CEILING DEMO PLAN KEYED NOTES 02.02 REMOVE EXISTING TECH STATION, PROJECTOR, PROJECTOR SCREEN, AND SPEAKERS. RETURN TO OWNER 02.48 REMOVE EXISTING DARK ROOM LIGHT AND RETURN TO OWNER FOR RE-USE. 02.49 REMOVE AND SALVAGE CURTAINS AND CEILING TRACKS FOR RE-USE. 02.50 REMOVE AND RE-INSTALL POWER PAPER ROLLER, RE: FLOOR AND ELECTRICAL PLANS. 02.51 DEMOLISH TRACK LIGHTING. GENERAL NOTES - DEMO 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS 2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW CONSTRUCTION 3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION 4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION 5 GENERAL CONTRACTOR SHALL PROVIDE A 6 MIL POLYETHYLENE DUST BARRIER FROM FLOOR TO DECK ABOVE TO ENSURE THAT ALL CORRIDORS OUTSIDE OF CONSTRUCTION AREA ARE KEPT CLEAN AND CLEAR OF DEBRIS AND OBSTRUCTIONS AT ALL TIMES. DUST BARRIER SHALL BE SEALED AIR TIGHT IN ALL PHASED AREAS OF CONSTRUCTION 6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC... 7 GENERAL CONTRACTOR TO PREVENT WATER BUILD-UP AND/OR DAMAGE FOUNDATIONS ON THE CONSTRUCTION SITE OR ADJACENT AREAS 8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303) 9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION 10 ALL EXISTING FURNITURE WILL BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 11 EXISTING ITEMS ON WALLS, SUCH AS CLOCKS, PAPER TOWEL DISPENSERS, WHITE BOARDS, TVS, COAT RACKS, ETC. TO BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 12 ALL EXISTING CMU WALLS HAVE EXISTING THICKENED SLABS UNDERNEATH THEM. BE AWARE WHEN CUTTING NEW TRENCHES FOR PLUMBING AND UNDERGROUND POWER. 13 ADDITIONAL INTERIOR WALLS AND OTHER ITEMS NOT GRAPHICALLY REPRESENTED ON THIS SHEET MAY REQURIE DEMOLITION, CONDUCT A SITE SURVEY TO DETERMINE THE FULL EXTENT OF INTERIOR DEMOLITION WORK. 14 NOTE: BYUI - IT IS CURRENTLY THE PLAN THAT EVERYTHING THAT IS DASHED IN RED WILL BE DEMOLISHED AND REMOVED. IF THERE IS ANYTHING THAT NEEDS TO BE RE-USED OR SAVED, PLEASE LET METHOD STUDIO KNOW. C A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 PLANRTARIUM RM 107 LIGHT TRAP I-Y HAZ. STORAGE 167 HAZ. STORAGE 166 ROCK LABORATORY 164 MEN'S T.R. 162 WOMEN'S T.R. 160 PIPE CHASE I-Q HALLWAY 1-T LAB PREP ROOM 161 ELEVATOR 1-M CUST. 147 STAIRWELL 1-P PHYSICAL GEOLOGY ROOM 158 PHYSICAL SCIENCE DISPLAY ROOM 156 SEISMOGRAPH ROOM 154 RESOURCE ROOM 150A AUTO TUTORIAL ROOM 171 STORAGE 171A LABORATORY RM 179 OFFICE 175 OFFICE 176 OFFICE 180 OFFICE 182 OFFICE 184 STORAGE RM 133 LECTURE HALL 172 SHOP RM 133A PHYSICS CLASSROOM 105 OFFICE 112 OFFICE 114 OFFICE 116 OFFICE 118 OFFICE 118A ADVANCED LAB 126 LECTURE HALL 127 LAB STORAGE RM 126A ADVANCED LAB 128 ADVANCED LAB RM 129 LABORATORY 141 OFFICE 150 OFFICE 148 OFFICE 146 OFFICE 144 WOMEN'S RM 132 MEN'S RM 134 PHYSICS LECTURE HALL 131 LECTURE HALL 145 PREP/STORAGE RM 143 OFFICE 110 OFFICE 186 MINEROLOGY LAB 149 HALLWAY I-N HALLWAY I-L HALLWAY I-G HALLWAY I-K HALLWAY I-F HALLWAY I-W HALLWAY I-D UNISEX RM 136 STORAGE 172A STORAGE 131A VESTIBULE I-A STAIRWELL I-C STAIRWELL I-B OFFICE 142 HALLWAY 1-U STAIRWELL 1-V BDF 138 STAIRWELL 1-S STAIRWELL 1-H STAIRWELL 1-E ELEVATOR 1-J LOADING DOCK ENTRANCE 02.5302.53 EXISTING WALLS TO REMAIN LEGEND INTERIOR PARTITION STUD AND GYPSUM BOARD WALLS AND/OR DEMOUNTABLE PARTITIONS, TO BE DEMOLISHED ACT CEILING TO BE DEMOLISHED INTERIOR PARTITION NON-REINFORCED CMU/MASONRY WALLS TO BE DEMOLISHED - PROTECT FLOORS AND SURROUNDING AREAS FROM DAMAGE N.I.C. GYP. BOARD CEILING TO BE DEMOLISHED 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 D131 LEVEL 01 DEMO RCP PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 01 REFLECTED CEILING DEMO PLAN KEYED NOTES 02.53 CEILINGS IN RESTROOMS WILL BE REMOVED AND REPLACED AS NEEDED TO REPLACE PLUMBING PIPES. GENERAL NOTES - DEMO 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS 2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW CONSTRUCTION 3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION 4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION 5 GENERAL CONTRACTOR SHALL PROVIDE A 6 MIL POLYETHYLENE DUST BARRIER FROM FLOOR TO DECK ABOVE TO ENSURE THAT ALL CORRIDORS OUTSIDE OF CONSTRUCTION AREA ARE KEPT CLEAN AND CLEAR OF DEBRIS AND OBSTRUCTIONS AT ALL TIMES. DUST BARRIER SHALL BE SEALED AIR TIGHT IN ALL PHASED AREAS OF CONSTRUCTION 6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC... 7 GENERAL CONTRACTOR TO PREVENT WATER BUILD-UP AND/OR DAMAGE FOUNDATIONS ON THE CONSTRUCTION SITE OR ADJACENT AREAS 8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303) 9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION 10 ALL EXISTING FURNITURE WILL BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 11 EXISTING ITEMS ON WALLS, SUCH AS CLOCKS, PAPER TOWEL DISPENSERS, WHITE BOARDS, TVS, COAT RACKS, ETC. TO BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 12 ALL EXISTING CMU WALLS HAVE EXISTING THICKENED SLABS UNDERNEATH THEM. BE AWARE WHEN CUTTING NEW TRENCHES FOR PLUMBING AND UNDERGROUND POWER. 13 ADDITIONAL INTERIOR WALLS AND OTHER ITEMS NOT GRAPHICALLY REPRESENTED ON THIS SHEET MAY REQURIE DEMOLITION, CONDUCT A SITE SURVEY TO DETERMINE THE FULL EXTENT OF INTERIOR DEMOLITION WORK. 14 NOTE: BYUI - IT IS CURRENTLY THE PLAN THAT EVERYTHING THAT IS DASHED IN RED WILL BE DEMOLISHED AND REMOVED. IF THERE IS ANYTHING THAT NEEDS TO BE RE-USED OR SAVED, PLEASE LET METHOD STUDIO KNOW. A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 INSTRUMENT RM 203A CHEMISTRY STOCK RM 213 OFFICE 213A CLASSROOM 270 CLASSROOM 268 MEN'S RM 266 WOMEN'S RM 264 OFFICE 252 OFFICE 253 OFFICE 250 OFFICE 248 OFFICE 246 OFFICE 244 OFFICE 242 OFFICE 240 OFFICE 238 WORK ROOM 243 OFFICE 236 OFFICE 234 OFFICE 239 OFFICE 237 OFFICE 235 OFFICE 233 OFFICE 232 CLASSROOM 255 CLASSROOM 277 OFFICE 259 OFFICE 261 OFFICE 263 OFFICE 265 MEN'S ROOM 226 WOMEN'S ROOM 220 GENERAL CHEM LAB 282 CHEM STOCK RM 282A OFFICE 286 OFFICE 285 OFFICE 289 OFFICE 290 OFFICE 291 OFFICE 292 OFFICE 294 OFFICE 296 OFFICE 298 CHEMISTRY LAB 204 CHEMISTRY LAB 214 CHEMISTRY LAB 210 CHEMISTRY PREP RM 281 CLASSROOM 276 CUST RM 267 BDF RM 280 CUST RM 228 INSTRUMENT RM 203B CLASSROOM 229 CLASSROOM 279 CLASSROOM 297 CLASSROOM 299 CHEMISTRY LAB 203 STORAGE 258 STORAGE RM 277A WORK ROOM 287A SEC/ RECEP RM 287 HALLWAY 2-U HALLWAY 2-D HALLWAY 2-F HALLWAY 2-S LOUNGE 2-V HALLWAY 2-J HALLWAY 2-M SECRETARY/RECEPTION RM 230 HALLWAY 2-K CLASSROOM 260 CLASSROOM 262 HALLWAY 2-L CUST STOR 216 STAIRWELL 2-HELEVATOR 2-G STAIRWELL 2-T HALLWAY 2-B STAIRWELL 2-A STAIRWELL 2-C A 1 B C D E F GH J K L MN P 2 3 4 5 6 7 8 02.53 02.56 TYP 02.32 ADVANCED PHYSICS LAB CHEM LAB RM OFFICE EXISTING WALLS TO REMAIN LEGEND INTERIOR PARTITION STUD AND GYPSUM BOARD WALLS AND/OR DEMOUNTABLE PARTITIONS, TO BE DEMOLISHED ACT CEILING TO BE DEMOLISHED INTERIOR PARTITION NON-REINFORCED CMU/MASONRY WALLS TO BE DEMOLISHED - PROTECT FLOORS AND SURROUNDING AREAS FROM DAMAGE N.I.C. GYP. BOARD CEILING TO BE DEMOLISHED 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 D132 LEVEL 02 DEMO RCP PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 02 REFLECTED CEILING DEMO PLAN KEYED NOTES 02.32 REMOVE EXTERIOR FUROUT WALL AND BLACK COVERING ON EXISTING WINDOW. PREP FOR WINDOW SILL AND NEW FINISHES. RE: FLOOR AND FINISH PLAN. 02.53 CEILINGS IN RESTROOMS WILL BE REMOVED AND REPLACED AS NEEDED TO REPLACE PLUMBING PIPES. 02.56 REMOVE EXISTING LIGHTING. GENERAL NOTES - DEMO 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION, AND TO CONTACT THE ARCHITECT WITH ANY UNFORESEEN CONDITIONS 2 GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURE/ASSEMBLIES/EQUIPMENT AS REQUIRED. REPAIR, PATCH AND/OR REPLACE EXISTING CONSTRUCTED ITEMS AND EQUIPMENT THAT ARE TO REMAIN AS REQUIRED FOR NEW CONSTRUCTION 3 GENERAL CONTRACTOR SHALL PATCH AND REPAIR TO MATCH EXISTING FINISHES AT WALLS, FLOORS, CEILINGS/SOFFITS, ETC... AS REQUIRED IN ARES NOT SPECIFICALLY CALLED OUT IN THE DRAWINGS BUT ARE IMPACTED BY CONSTRUCTION 4 REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION COORDINATION 5 GENERAL CONTRACTOR SHALL PROVIDE A 6 MIL POLYETHYLENE DUST BARRIER FROM FLOOR TO DECK ABOVE TO ENSURE THAT ALL CORRIDORS OUTSIDE OF CONSTRUCTION AREA ARE KEPT CLEAN AND CLEAR OF DEBRIS AND OBSTRUCTIONS AT ALL TIMES. DUST BARRIER SHALL BE SEALED AIR TIGHT IN ALL PHASED AREAS OF CONSTRUCTION 6 UPON COMPLETION OF CONSTRUCTION IN EACH PHASE IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO THOROUGHLY CLEAN ALL AREAS IN WHICH CONSTRUCTION TOOK PLACE AND AREAS IMPACTED BY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CLEAN ALL CARPET, REMOVE ALL DUST, CLEAN DOORS AND FRAMES, LIGHT FIXTURES, CEILING SYSTEMS, MECHANICAL GRILLES, ELECTRICAL PANELS, WINDOW SYSTEMS, GLAZING, ETC... 7 GENERAL CONTRACTOR TO PREVENT WATER BUILD-UP AND/OR DAMAGE FOUNDATIONS ON THE CONSTRUCTION SITE OR ADJACENT AREAS 8 GENERAL CONTRACTOR TO KEEP AN ACTIVE PEDESTRIAN PATHWAY TO AND AT EGRESS ROUTES FREE OF OBSTRUCTIONS AT ALL TIMES. CONTRACTOR TO PROVIDE PROTECTION TO PEDESTRIANS BEFORE DEMOLITION (IBC 3303) 9 GENERAL CONTRACTOR TO MAINTAIN EXITS, EXISTING STRUCTURAL ELEMENTS, APPLIED FIREPROOFING PROTECTION DEVICES, AND SANITARY SAFEGUARDS AT ALL TIMES DURING DEMOLITION AND CONSTRUCTION 10 ALL EXISTING FURNITURE WILL BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 11 EXISTING ITEMS ON WALLS, SUCH AS CLOCKS, PAPER TOWEL DISPENSERS, WHITE BOARDS, TVS, COAT RACKS, ETC. TO BE REMOVED BY OWNER PRIOR TO CONSTRUCTION. 12 ALL EXISTING CMU WALLS HAVE EXISTING THICKENED SLABS UNDERNEATH THEM. BE AWARE WHEN CUTTING NEW TRENCHES FOR PLUMBING AND UNDERGROUND POWER. 13 ADDITIONAL INTERIOR WALLS AND OTHER ITEMS NOT GRAPHICALLY REPRESENTED ON THIS SHEET MAY REQURIE DEMOLITION, CONDUCT A SITE SURVEY TO DETERMINE THE FULL EXTENT OF INTERIOR DEMOLITION WORK. 14 NOTE: BYUI - IT IS CURRENTLY THE PLAN THAT EVERYTHING THAT IS DASHED IN RED WILL BE DEMOLISHED AND REMOVED. IF THERE IS ANYTHING THAT NEEDS TO BE RE-USED OR SAVED, PLEASE LET METHOD STUDIO KNOW. A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 COMPACT FILL PLANRTARIUM RM 107 LIGHT TRAP I-Y STORAGE 18 CUST OFFICE 16 CUSTODIAL LAUNDRY RM 14 MEN'S RM 66 WOMEN'S RM 64 MECHANICAL ROOM 69 MECHANICAL RM 10 VESTIBULE O-A MECH RM 12 HALLWAY O-C STORAGE 63 STAIRWELL O-B PIPE CHASE O-Q ELEVATOR O-D MECH RM 67 CUST RM 68 STAIRWELL 0-F STORAGE 20 ELEVATOR 0-K ELEC VAULT 80 COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E T U N N E L HALLWAY 0-N CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE DARK ROOM 59D COMPUTER LAB 59 PHOTO STUDIO 51 VESTIBULE 59C OFFICE 57 EQUIP / CHECK OUT 59A STORAGE 59B OFFICE 55 FILM 59E ACOUSTICS STUDIO 52B STORAGE 51A CHANGING 51B VESTIBULE 0-H OPTICS LAB 52A PHYSICS LAB 52 STORAGE 52C CLASSROOM 50 2' - 0 " 3' - 0" 2' - 0 " ROOF LINE ABOVE SOFFIT LINE ABOVE 2' - 0" A414 D2 A411A A1 A412 1 A414E4 D1 E1 E2 A414 C1 68 69 52B 52A 50 55 51A 59.1 59A.1 51B 52.1 59.2 59A.2 59D 51.1 51.2 57 52C 59E 59C 0-H 52.2 F3 A414B1 B2 A. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK B. DO NOT SCALE THE DRAWINGS C. ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT D. ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED, UNLESS NOTED OTHERWISE E. SEE G000 SHEET SERIES FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT F. COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OWNER FURNISHED, OWNER INSTALLED G. SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES H. SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES I. SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS J. SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION K. VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES AE400. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS L. ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS. M. SEMI-FLUSH LIGHT FIXTURE TO BE CENTERED OVER UNIT KITCHEN ISLANDS & CENTERED WITHIN FIXED DINING ROOMS AT UNITS. SEE AE400 UNIT SHEET SERIES FOR LOCATIONS. N. DOOR OPENINGS IN FRAME CONSTRUCTION WITH NO SPECIFIED DIMENSION ARE EITHER CENTERED IN THE LENGTH OF WALL RUN OR (IF DRAWN NEAR CORNER) LOCATED 4" FROM THE FACE OF ADJACENT STUD. ASSUME CENTERED IN FACE OF JAMB UNLESS NOTED OTHERWISE. O. ALL PANEL MOLDING TO HAVE MITERED CORNERS AND CONSISTENT MOUNTING HEIGHT AND SPACING WITHIN THE SAME SPACE. GENERAL NOTES 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A100 LEVEL 00 FLOOR PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 00 FLOOR PLAN A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 PLANRTARIUM RM 107 LIGHT TRAP I-Y HAZ. STORAGE 167 HAZ. STORAGE 166 ROCK LABORATORY 164 MEN'S T.R. 162 WOMEN'S T.R. 160 PIPE CHASE I-Q HALLWAY 1-T LAB PREP ROOM 161 ELEVATOR 1-M CUST. 147 STAIRWELL 1-P 1,104 SF PHYSICAL GEOLOGY ROOM 158 PHYSICAL SCIENCE DISPLAY ROOM 156 SEISMOGRAPH ROOM 154 RESOURCE ROOM 150A AUTO TUTORIAL ROOM 171 STORAGE 171A LABORATORY RM 179 OFFICE 175 OFFICE 176 OFFICE 180 OFFICE 182 OFFICE 184 STORAGE RM 133 LECTURE HALL 172 SHOP RM 133A PHYSICS CLASSROOM 105 OFFICE 112 OFFICE 114 OFFICE 116 OFFICE 118 OFFICE 118A ADVANCED LAB 126 LECTURE HALL 127 LAB STORAGE RM 126A ADVANCED LAB 128 ADVANCED LAB RM 129 LABORATORY 141 OFFICE 150 OFFICE 148 OFFICE 146 OFFICE 144 WOMEN'S RM 132 MEN'S RM 134 PHYSICS LECTURE HALL 131 LECTURE HALL 145 PREP/STORAGE RM 143 OFFICE 110 OFFICE 186 MINEROLOGY LAB 149 HALLWAY I-N HALLWAY I-L HALLWAY I-G HALLWAY I-K HALLWAY I-F HALLWAY I-W HALLWAY I-D UNISEX RM 136 STORAGE 172A STORAGE 131A VESTIBULE I-A STAIRWELL I-C STAIRWELL I-B OFFICE 142 HALLWAY 1-U STAIRWELL 1-V BDF 138 STAIRWELL 1-S STAIRWELL 1-H STAIRWELL 1-E ELEVATOR 1-J A415 A1 A201D1 A201 B1 A201 A1 A414 D3 26.1426.1426.14 02.5202.52 02.52 6.06 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A101 LEVEL 01 FLOOR PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set1/8" = 1'-0"A1 LEVEL 01 FLOOR PLAN GENERAL NOTES - FLOOR PLAN 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE THE DRAWINGS 3 ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT 4 ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED, UNLESS NOTED OTHERWISE 5 SEE G000 SERIES SHEETS FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT 6 COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OWNER FURNISHED, OWNER INSTALLED 7 SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES 8 SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES 9 SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS 10 SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION 11 VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES A400. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS 12 ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS 13 SEMI-FLUSH LIGHT FIXTURE TO BE CENTERED OVER UNIT KITCHEN ISLANDS & CENTERED WITHIN FIXED DINING ROOMS AT UNITS. SEE A400's UNIT SHEET SERIES FOR LOCATIONS 14 DOOR OPENINGS IN FRAME CONSTRUCTION WITH NO SPECIFIED DIMENSION ARE EITHER CENTERED IN THE LENGTH OF WALL RUN OR (IF DRAWN NEAR CORNER) LOCATED 4" FROM THE FACE OF ADJACENT STUD. ASSUME CENTERED IN FACE OF JAMB UNLESS NOTED OTHERWISE KEYED NOTES 02.52 EXISTING CASEWORK TO REMAIN. 6.06 CUT COUNTERTOP AROUND COLUMN. FEILD VERIFY. 26.14 ALL NEW STALLS, FIXTURES AND PLUMBING TO BE REPLACED TO MATCH EXISTING LAYOUT. RE: ELEVATIONS AND FINSIH PLANS FOR NEW FINISHES. A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 INSTRUMENT RM 203A CHEMISTRY STOCK RM 213 OFFICE 213A CLASSROOM 270 CLASSROOM 268 MEN'S RM 266 WOMEN'S RM 264 OFFICE 252 OFFICE 253 OFFICE 250 OFFICE 248 OFFICE 246 OFFICE 244 OFFICE 242 OFFICE 240 OFFICE 238 WORK ROOM 243 OFFICE 236 OFFICE 234 OFFICE 239 OFFICE 237 OFFICE 235 OFFICE 233 OFFICE 232 CLASSROOM 255 CLASSROOM 277 OFFICE 259 OFFICE 261 OFFICE 263 OFFICE 265 MEN'S ROOM 226 WOMEN'S ROOM 220 GENERAL CHEM LAB 282 CHEM STOCK RM 282A OFFICE 286 OFFICE 285 OFFICE 289 OFFICE 290 OFFICE 291 OFFICE 292 OFFICE 294 OFFICE 296 OFFICE 298 CHEMISTRY LAB 204 CHEMISTRY LAB 214 CHEMISTRY LAB 210 CHEMISTRY PREP RM 281 CLASSROOM 276 CUST RM 267 BDF RM 280 CUST RM 228 INSTRUMENT RM 203B CLASSROOM 229 CLASSROOM 279 CLASSROOM 297 CLASSROOM 299 CHEMISTRY LAB 203 STORAGE 258 STORAGE RM 277A WORK ROOM 287A SEC/ RECEP RM 287 HALLWAY 2-U HALLWAY 2-D HALLWAY 2-F HALLWAY 2-S LOUNGE 2-V HALLWAY 2-J HALLWAY 2-M SECRETARY/RECEPTION RM 230 HALLWAY 2-K CLASSROOM 260 CLASSROOM 262 HALLWAY 2-L CUST STOR 216 STAIRWELL 2-HELEVATOR 2-G STAIRWELL 2-T HALLWAY 2-B STAIRWELL 2-A STAIRWELL 2-C A415 A3 1,553 SF BIO-CHEMISTRY LAB 272 272 276 A413 1 SF1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A102 LEVEL 02 FLOOR PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"(REF: A1/A201)A1 LEVEL 02 FLOOR PLAN GENERAL NOTES - FLOOR PLAN 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE THE DRAWINGS 3 ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT 4 ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED, UNLESS NOTED OTHERWISE 5 SEE G000 SERIES SHEETS FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT 6 COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OWNER FURNISHED, OWNER INSTALLED 7 SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES 8 SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES 9 SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS 10 SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION 11 VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES A400. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS 12 ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS 13 SEMI-FLUSH LIGHT FIXTURE TO BE CENTERED OVER UNIT KITCHEN ISLANDS & CENTERED WITHIN FIXED DINING ROOMS AT UNITS. SEE A400's UNIT SHEET SERIES FOR LOCATIONS 14 DOOR OPENINGS IN FRAME CONSTRUCTION WITH NO SPECIFIED DIMENSION ARE EITHER CENTERED IN THE LENGTH OF WALL RUN OR (IF DRAWN NEAR CORNER) LOCATED 4" FROM THE FACE OF ADJACENT STUD. ASSUME CENTERED IN FACE OF JAMB UNLESS NOTED OTHERWISE F F F CR CR FF A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 STORAGE 18 CUST OFFICE 16 CUSTODIAL LAUNDRY RM 14 MEN'S RM 66 WOMEN'S RM 64 MECHANICAL ROOM 69 MECHANICAL RM 10 VESTIBULE O-A MECH RM 12 HALLWAY O-C STORAGE 63 STAIRWELL O-BPIPE CHASE O-Q ELEVATOR O-D MECH RM 67 47 SF CUST RM 68 STAIRWELL 0-F STORAGE 20 ELEVATOR 0-K ELEC VAULT 80 HALLWAY 0-N COMPACT FILL COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E T U N N E L CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE LIGHT TRAP I-Y PLANRTARIUM RM 107 5' - 5"21' - 3 13/16"5' - 5"14' - 4 3/4"10' - 5"10' - 5"10' - 5"6' - 4" 10 ' - 9 1 / 2 " 11 ' - 1 " 8' - 5 " 12 ' - 5 " 19 ' - 0 1 / 2 " 4' - 3 1 / 2 " 744 SF CLASSROOM 50 286 SF DARK ROOM 59D 908 SF COMPUTER LAB 59 983 SF PHOTO STUDIO 51 26 SF VESTIBULE 59C 120 SF OFFICE 57 169 SF EQUIP / CHECK OUT 59A 121 SF STORAGE 59B 120 SF OFFICE 55 33 SF FILM 59E 114 SF ACOUSTICS STUDIO 52B 141 SF STORAGE 51A 50 SF CHANGING 51B 120 SF VESTIBULE 0-H 118 SF OPTICS LAB 52A 946 SF PHYSICS LAB 52 163 SF STORAGE 52C 14' - 10"5' - 0" 3' - 0 " 22 ' - 6 " 11 1/4"1'-11 1/4" 11' - 10" 24' - 1 1/2" 5' - 6"6' - 11"26' - 4"9' - 9 3/8" 3' - 1 " SF6 b SA 4 b SA4 b SA4 a SA4 a SB 4 a SB4 a SB 4 a SF 6 b SA6 a SA 4 a SB 3 a SB3 a SA 4 a SA 4 a SA 4 a SB3 aSA 4 a SA 4 a SB4 a SA 4 b SA 4 bSA4b SA 4 bSA 4 a SG4 b SA 4 b SA4 a SA 4 a SA4 a SA6 a SA 4 a SA4 b SA 4 b SB 3 a SB3 a SB 3 a SA6 a SB3 a SA 4 b SA4 b SB 6 a SA 4 a SB 4 a CD 6 SH 2 b SB1 a SB3 a SA 4 b SA4 b SB3 aSB4a SA4 a SA 6 a 0' - 9" 3' - 1 1 / 2 " 5' - 5 " SA4 a SA4 a 7' - 6 1 / 2 " 21 ' - 8 " 2' - 6 " 0' - 2 1/2"6' - 0" 8' - 1 0 " 7" SB1 a SB1 a CD 6 CD 6 SH2 b SB 3 b SG 4 b MIN 3'-0" CLEAR 4'-9" ALIGN 4" 8 3 / 4 " 8 1 / 4 " 7 1/8" A. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK B. DO NOT SCALE THE DRAWINGS C. ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT D. ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED, UNLESS NOTED OTHERWISE E. SEE G000 SHEET SERIES FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT F. COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OWNER FURNISHED, OWNER INSTALLED G. SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES H. SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES I. SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS J. SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION K. VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES AE400. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS L. ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS. M. SEMI-FLUSH LIGHT FIXTURE TO BE CENTERED OVER UNIT KITCHEN ISLANDS & CENTERED WITHIN FIXED DINING ROOMS AT UNITS. SEE AE400 UNIT SHEET SERIES FOR LOCATIONS. N. DOOR OPENINGS IN FRAME CONSTRUCTION WITH NO SPECIFIED DIMENSION ARE EITHER CENTERED IN THE LENGTH OF WALL RUN OR (IF DRAWN NEAR CORNER) LOCATED 4" FROM THE FACE OF ADJACENT STUD. ASSUME CENTERED IN FACE OF JAMB UNLESS NOTED OTHERWISE. O. ALL PANEL MOLDING TO HAVE MITERED CORNERS AND CONSISTENT MOUNTING HEIGHT AND SPACING WITHIN THE SAME SPACE. GENERAL NOTES LEGEND: INT. PARTITION HEAD CONDITIONS TYPICAL PARTITION FLOOR TO FLOOR/CEILING/ROOF 1-HR FIRE RATED PARTITION 2-HR FIRE RATED PARTITION b - ACOUSTIC PARTITION a - PARTITION EXTENDS FROM FLOOR TO 6" ABOVE CEILING WALL TYPE HEAD CONDITION LEGEND IF NULL = TYPICAL PARTITION FLOOR TO FLOOR/CEILING/ROOF a = PARTITION EXTEND FROM FLOOR TO 6" ABOVE CEILING b = ACOUSTIC PARTITION NON-FIRE RATED WALL TAG (description) SA6a CORE MATERIAL (SEE LEGEND) LAYERS (SEE LEGEND) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) FIRE RATED WALL TAG (description) FIRE RATING (IF APPLICABLE) 1SA6a CORE MATERIAL (SEE LEGEND BELOW) LAYERS (REF PARTITIONS SHEET) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) C = CONCRETE WALLS, MASONRY S = STEEL STUDS CORE MATERIAL LEGEND CORE SIZE LEGEND STEEL STUDS 1 =A7/8" 2 = 1 5/8" 3 = 2 1/2" 4 = 3 5/8" 5 = 6 = 6" 8 = 8" SUPERSCRIPT NOTES - A - HAT CHANNEL FURRING IN LIEU OF METAL STUD 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A120 LEVEL 00 DIMENSION PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set1/8" = 1'-0"A1 LEVEL 00 DIMENSION PLAN DN A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 PLANRTARIUM RM 107 LIGHT TRAP I-Y HAZ. STORAGE 167 HAZ. STORAGE 166 ROCK LABORATORY 164 MEN'S T.R. 162 WOMEN'S T.R. 160 PIPE CHASE I-Q HALLWAY 1-T LAB PREP ROOM 161 ELEVATOR 1-M CUST. 147 STAIRWELL 1-P PHYSICAL GEOLOGY ROOM 158 PHYSICAL SCIENCE DISPLAY ROOM 156 SEISMOGRAPH ROOM 154 RESOURCE ROOM 150A AUTO TUTORIAL ROOM 171 STORAGE 171A LABORATORY RM 179 OFFICE 175 OFFICE 176 OFFICE 180 OFFICE 182 OFFICE 184 STORAGE RM 133 LECTURE HALL 172 SHOP RM 133A PHYSICS CLASSROOM 105 OFFICE 112 OFFICE 114 OFFICE 116 OFFICE 118 OFFICE 118A ADVANCED LAB 126 LECTURE HALL 127 LAB STORAGE RM 126A ADVANCED LAB 128 ADVANCED LAB RM 129 LABORATORY 141 OFFICE 150 OFFICE 148 OFFICE 146 OFFICE 144 WOMEN'S RM 132 MEN'S RM 134 PHYSICS LECTURE HALL 131 LECTURE HALL 145 PREP/STORAGE RM 143 OFFICE 110 OFFICE 186 MINEROLOGY LAB 149 HALLWAY I-N HALLWAY I-L HALLWAY I-G HALLWAY I-K HALLWAY I-F HALLWAY I-W HALLWAY I-D UNISEX RM 136 STORAGE 172A STORAGE 131A VESTIBULE I-A STAIRWELL I-C STAIRWELL I-B OFFICE 142 HALLWAY 1-U STAIRWELL 1-V BDF 138 STAIRWELL 1-S STAIRWELL 1-H STAIRWELL 1-E ELEVATOR 1-J 14'-1 1/4"6'-3 5/8"14'-1 1/2"5/8" A. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK B. DO NOT SCALE THE DRAWINGS C. ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT D. ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED, UNLESS NOTED OTHERWISE E. SEE G000 SHEET SERIES FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT F. COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OWNER FURNISHED, OWNER INSTALLED G. SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES H. SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES I. SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS J. SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION K. VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES AE400. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS L. ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS. M. SEMI-FLUSH LIGHT FIXTURE TO BE CENTERED OVER UNIT KITCHEN ISLANDS & CENTERED WITHIN FIXED DINING ROOMS AT UNITS. SEE AE400 UNIT SHEET SERIES FOR LOCATIONS. N. DOOR OPENINGS IN FRAME CONSTRUCTION WITH NO SPECIFIED DIMENSION ARE EITHER CENTERED IN THE LENGTH OF WALL RUN OR (IF DRAWN NEAR CORNER) LOCATED 4" FROM THE FACE OF ADJACENT STUD. ASSUME CENTERED IN FACE OF JAMB UNLESS NOTED OTHERWISE. O. ALL PANEL MOLDING TO HAVE MITERED CORNERS AND CONSISTENT MOUNTING HEIGHT AND SPACING WITHIN THE SAME SPACE. GENERAL NOTES LEGEND: INT. PARTITION HEAD CONDITIONS TYPICAL PARTITION FLOOR TO FLOOR/CEILING/ROOF 1-HR FIRE RATED PARTITION 2-HR FIRE RATED PARTITION b - ACOUSTIC PARTITION a - PARTITION EXTENDS FROM FLOOR TO 6" ABOVE CEILING WALL TYPE HEAD CONDITION LEGEND IF NULL = TYPICAL PARTITION FLOOR TO FLOOR/CEILING/ROOF a = PARTITION EXTEND FROM FLOOR TO 6" ABOVE CEILING b = ACOUSTIC PARTITION NON-FIRE RATED WALL TAG (description) SA6a CORE MATERIAL (SEE LEGEND) LAYERS (SEE LEGEND) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) FIRE RATED WALL TAG (description) FIRE RATING (IF APPLICABLE) 1SA6a CORE MATERIAL (SEE LEGEND BELOW) LAYERS (REF PARTITIONS SHEET) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) C = CONCRETE WALLS, MASONRY S = STEEL STUDS CORE MATERIAL LEGEND CORE SIZE LEGEND STEEL STUDS 1 =A7/8" 2 = 1 5/8" 3 = 2 1/2" 4 = 3 5/8" 5 = 6 = 6" 8 = 8" SUPERSCRIPT NOTES - A - HAT CHANNEL FURRING IN LIEU OF METAL STUD 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A121 LEVEL 01 DIMENSION PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 01 DIMENSION PLAN F F A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 INSTRUMENT RM 203A CHEMISTRY STOCK RM 213 OFFICE 213A CLASSROOM 270 CLASSROOM 268 MEN'S RM 266 WOMEN'S RM 264 OFFICE 252 OFFICE 253 OFFICE 250 OFFICE 248 OFFICE 246 OFFICE 244 OFFICE 242 OFFICE 240 OFFICE 238 WORK ROOM 243 OFFICE 236 OFFICE 234 OFFICE 239 OFFICE 237 OFFICE 235 OFFICE 233 OFFICE 232 CLASSROOM 255 CLASSROOM 277 OFFICE 259 OFFICE 261 OFFICE 263 OFFICE 265 MEN'S ROOM 226 WOMEN'S ROOM 220 GENERAL CHEM LAB 282 CHEM STOCK RM 282A OFFICE 286 OFFICE 285 OFFICE 289 OFFICE 290 OFFICE 291 OFFICE 292 OFFICE 294 OFFICE 296 OFFICE 298 CHEMISTRY LAB 204 CHEMISTRY LAB 214 CHEMISTRY LAB 210 CHEMISTRY PREP RM 281 CLASSROOM 276 CUST RM 267 BDF RM 280 CUST RM 228 INSTRUMENT RM 203B CLASSROOM 229 CLASSROOM 279 CLASSROOM 297 CLASSROOM 299 CHEMISTRY LAB 203 STORAGE 258 STORAGE RM 277A WORK ROOM 287A SEC/ RECEP RM 287 HALLWAY 2-U HALLWAY 2-D HALLWAY 2-F HALLWAY 2-S LOUNGE 2-V HALLWAY 2-J HALLWAY 2-M SECRETARY/RECEPTION RM 230 HALLWAY 2-K CLASSROOM 260 CLASSROOM 262 HALLWAY 2-L CUST STOR 216 STAIRWELL 2-HELEVATOR 2-G STAIRWELL 2-T HALLWAY 2-B STAIRWELL 2-A STAIRWELL 2-C 1,553 SF BIO-CHEMISTRY LAB 272 ALIGN 2' - 8 " 11 ' - 2 1 / 2 " 3' - 1" 3' - 0" 5' - 1" 0' - 4 " 5' - 1 0 " F . V . 5' - 6 " 2 3 / 8 " 15 ' - 5 " SB4 a 4' - 5 7/8" 8' - 3" 9 5 / 8 " SA6 a SA 4 b SA4 b SB4 a 3' - 0 " 0' - 2 1/8" 0' - 8" SB 3 b SB 4 b SA6 SB 3 a A. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK B. DO NOT SCALE THE DRAWINGS C. ALL EXPOSED INTERIOR COLUMNS TO BE PAINTED WITH INTUMESCENT PAINT D. ALL EXPOSED EXTERIOR STEEL TO BE GALVANIZED, UNLESS NOTED OTHERWISE E. SEE G000 SHEET SERIES FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT F. COORDINATE ALL EQUIPMENT AND ACCESSORIES, INCLUDING ITEMS THAT ARE OWNER FURNISHED, OWNER INSTALLED G. SEE SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES H. SEE SHEET SERIES A600 FOR DOOR AND WINDOW TYPES I. SEE ELEVATIONS AND FINISH SCHEDULES FOR SURFACE TREATMENTS AT WALLS J. SEE ELEVATIONS, SECTIONS, AND DETAILS FOR ADDITIONAL WALL CONSTRUCTION INFORMATION K. VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES AE400. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS L. ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS. M. SEMI-FLUSH LIGHT FIXTURE TO BE CENTERED OVER UNIT KITCHEN ISLANDS & CENTERED WITHIN FIXED DINING ROOMS AT UNITS. SEE AE400 UNIT SHEET SERIES FOR LOCATIONS. N. DOOR OPENINGS IN FRAME CONSTRUCTION WITH NO SPECIFIED DIMENSION ARE EITHER CENTERED IN THE LENGTH OF WALL RUN OR (IF DRAWN NEAR CORNER) LOCATED 4" FROM THE FACE OF ADJACENT STUD. ASSUME CENTERED IN FACE OF JAMB UNLESS NOTED OTHERWISE. O. ALL PANEL MOLDING TO HAVE MITERED CORNERS AND CONSISTENT MOUNTING HEIGHT AND SPACING WITHIN THE SAME SPACE. GENERAL NOTES LEGEND: INT. PARTITION HEAD CONDITIONS TYPICAL PARTITION FLOOR TO FLOOR/CEILING/ROOF 1-HR FIRE RATED PARTITION 2-HR FIRE RATED PARTITION b - ACOUSTIC PARTITION a - PARTITION EXTENDS FROM FLOOR TO 6" ABOVE CEILING WALL TYPE HEAD CONDITION LEGEND IF NULL = TYPICAL PARTITION FLOOR TO FLOOR/CEILING/ROOF a = PARTITION EXTEND FROM FLOOR TO 6" ABOVE CEILING b = ACOUSTIC PARTITION NON-FIRE RATED WALL TAG (description) SA6a CORE MATERIAL (SEE LEGEND) LAYERS (SEE LEGEND) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) FIRE RATED WALL TAG (description) FIRE RATING (IF APPLICABLE) 1SA6a CORE MATERIAL (SEE LEGEND BELOW) LAYERS (REF PARTITIONS SHEET) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) C = CONCRETE WALLS, MASONRY S = STEEL STUDS CORE MATERIAL LEGEND CORE SIZE LEGEND STEEL STUDS 1 =A7/8" 2 = 1 5/8" 3 = 2 1/2" 4 = 3 5/8" 5 = 6 = 6" 8 = 8" SUPERSCRIPT NOTES - A - HAT CHANNEL FURRING IN LIEU OF METAL STUD 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A122 LEVEL 02 DIMENSION PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 02 DIMENSION PLAN A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 PLANRTARIUM RM 107 LIGHT TRAP I-Y STORAGE 18 CUST OFFICE 16 CUSTODIAL LAUNDRY RM 14 MEN'S RM 66 WOMEN'S RM 64 MECHANICAL ROOM 69 MECHANICAL RM 10 VESTIBULE O-A MECH RM 12 HALLWAY O-C STORAGE 63 STAIRWELL O-B PIPE CHASE O-Q ELEVATOR O-D MECH RM 67 CUST RM 68 STAIRWELL 0-F STORAGE 20 ELEVATOR 0-K ELEC VAULT 80 HALLWAY 0-N COMPACT FILL COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E T U N N E L CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE CLASSROOM 50 DARK ROOM 59D COMPUTER LAB 59 PHOTO STUDIO 51 VESTIBULE 59C OFFICE 57 EQUIP / CHECK OUT 59A STORAGE 59B OFFICE 55 FILM 59E ACOUSTICS STUDIO 52B STORAGE 51A CHANGING 51B VESTIBULE 0-H OPTICS LAB 52A PHYSICS LAB 52 STORAGE 52C B2 9' - 0"B2 9' - 0" A1 9' - 0"A1 9' - 0" A1 9' - 0" A1 9' - 0" B1 9' - 0" A1 9' - 0" A1 9' - 0" A1 9' - 0" A1 9' - 0" A1 9' - 0" A1 9' - 0" A1 9' - 0" A1 9' - 0" A1 10' - 0" B1 9' - 0" A1 9' - 0" E-1 A1 9' - 0"A1 9' - 0"A1 9' - 0"A1 9' - 0" A1 9' - 0" 10.21 10.24 10.22 10.23 E-1 10.26 26.09 26.10 26.13 09.26 23.01 26.01 23.01 TYP 26.01 TYP 26.15 TYP 23.01TYP 23.01 26.01 26.06 TYP TYP 23.01 26.01 26.01 TYP 23.02 23.01 26.01 23.01 TYP TYP TYP 23.0223.02 26.17 10.32 09.24 09.24 A514 C1 ACT-01: 2' x 2' LAY-IN ACOUSTICAL TILE & SUSPENSION SYSTEM, RE: FINISH SCHEDULE CEILING LEGEND TYPE A1 5/8" GYPSUM BOARD (PAINTED PNT-01 UNLESS NOTED ON PLAN) ON METAL STUD. TYPE B1 5/8" GYPSUM BOARD (PAINTED PNT-01 UNLESS NOTED ON PLAN) ON METAL SUSPENSION SYSTEM. TYPE B2 EXPOSED STRUCTURE. PAINT PNT-02, RE: FINISH LEGEND TYPE E-1 NOTE: ALL DROPS NEED TO BE NON-COMBUSTIBLE METAL FRAMING OR LIGHT GAUGE METAL FRAMING AND MEET L/360 STANDARD FOR ALLOWABLE DEFLECTION. ACCOUSTIC FOAM ON 5/8" GYPSUM BOARD ON METAL SUSPENSION SYSTEM. TYPE B3 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A130 LEVEL 00 RCP PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 00 REFLECTED CEILING PLAN GENERAL NOTES - CEILING 1 VERIFY ALL MECHANICAL DUCT, GRILLE, DIFFUSER, AND VENT LOCATIONS WITH MECHANICAL DRAWINGS 2 CEILING GRID SHOWN IS ONLY A GRAPHIC REPRESENTATION OF CEILING. CEILING PATTERN IS TO BE CENTERED IN THE ROOM, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL VERIFY ACTUAL GRID LAYOUT/LOCATION 3 VERIFY AND COORDINATE ALL MECHANICAL DUCT, GRILL DIFFUSER & LOCATIONS, VENTS, AND QUANTITY WITH MECHANICAL PLANS 4 VERIFY ALL LIGHTS, SMOKE DETECTORS, AND EXIT DEVICE LOCATIONS AND QUANTITIES WITH ELECTRICAL DRAWINGS. SEE ARCHITECTURE FOR LIGHT LAYOUT LOCATION. LIGHT FIXTURES TO BE CENTERED AND SYMMETRICALLY LOCATED IN UNITS AND SHARED SPACES UNLESS NOTED OTHERWISE 5 PROVIDE DEFLECTION TRACKS AT TOP OF ALL COLD FORMED METAL FRAMING; SEE SHEET SERIES AE500 6 MAKE FACTORY EDGE WHERE TILE IS CUT TYPICAL FOR ALL LAY-IN ACOUSTICAL TILE WITH REGULAR EDGE 7 SEE SHEET SERIES A600 FOR FINISH MATERIAL SPECIFICATIONS 8 VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES A400's. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS 9 ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS KEYED NOTES 09.24 ADD ALTERNATE 4 - 4" PREMIUM ACCOUSTIC FOAM PANELS APPLIED TO WALLS AND CIELING OF THE ACCOUSTICS LAB 52B4 09.26 1'-6" X 6'-0" ACOUSTIC PANEL. ARMSTRONG TECTUM DIRECT-ATTACHED TO BOTTOM OF FLOOR DECK AS BASIS OF DESIGN. PAINT TO MATCH DECK PAINT. 10.21 WALL MOUNTED PROJECTOR SCREEN, OFOI 10.22 RE-USED EXISTING BLACKOUT CURTAIN AND CEILING TRACK, CFCI 10.23 BACKDROP CANVAS CURTAIN AND CEILING TRACK, CFCI. ENSURE THAT THEY ARE STRUCTURALLY AND SEISMICALLY SUPPORTED. 10.24 CEILING MOUNTED PROJECTOR, OFCI 10.26 RE-INSTALL POWER PAPER ROLLER, RE: ELECTRICAL PLANS. 10.32 BID ALTERNATE 6 - LIGHT FIXTURE STRUCTURE AND RAIL WITH OUTLET AND SINGLE ACCORDIAN ARM IN PHOTO STUDIO 51. OWNER TO PROVIDE LIGHT, RE: SPECIFICATIONS 23.01 MECHANICAL DUCT, RE: MECHANICAL 23.02 MECHANICAL EQUIPMENT, RE: MECHANICAL 26.01 LIGHT FIXTURE, RE: ELECT. 26.06 DUPLEX POWER RECEPTACLE, RE: ELECTRICAL 26.09 HAIR LIGHT, RE: ELECTRICAL 26.10 DARK ROOM LIGHT, OFOI 26.13 CABLE TRAY BELOW THE LAY-IN CEILING. MOUNT TO THE FLOOR DECK ABOVE AT 9'-0" AFF. DESIGN STRURCTURAL LOAD FOR 5LBS PER SQUARE FOOT. 26.15 WALL MOUNTED CLOCK. RE: ELECTRICAL DRAWINGS 26.17 BID ALTERNATE 7 - ADDITIONAL HAIR LIGHT IN PHOTO STUDIO 51, RE: SPECIFICATION F F A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 PLANRTARIUM RM 107 LIGHT TRAP I-Y HAZ. STORAGE 167 HAZ. STORAGE 166 ROCK LABORATORY 164 MEN'S T.R. 162 WOMEN'S T.R. 160 PIPE CHASE I-Q HALLWAY 1-T LAB PREP ROOM 161 ELEVATOR 1-M CUST. 147 STAIRWELL 1-P PHYSICAL GEOLOGY ROOM 158 PHYSICAL SCIENCE DISPLAY ROOM 156 SEISMOGRAPH ROOM 154 RESOURCE ROOM 150A AUTO TUTORIAL ROOM 171 STORAGE 171A LABORATORY RM 179 OFFICE 175 OFFICE 176 OFFICE 180 OFFICE 182 OFFICE 184 STORAGE RM 133 LECTURE HALL 172 SHOP RM 133A PHYSICS CLASSROOM 105 OFFICE 112 OFFICE 114 OFFICE 116 OFFICE 118 OFFICE 118A ADVANCED LAB 126 LECTURE HALL 127 LAB STORAGE RM 126A ADVANCED LAB 128 ADVANCED LAB RM 129 LABORATORY 141 OFFICE 150 OFFICE 148 OFFICE 146 OFFICE 144 WOMEN'S RM 132 MEN'S RM 134 PHYSICS LECTURE HALL 131 LECTURE HALL 145 PREP/STORAGE RM 143 OFFICE 110 OFFICE 186 MINEROLOGY LAB 149 HALLWAY I-N HALLWAY I-L HALLWAY I-G HALLWAY I-K HALLWAY I-F HALLWAY I-W HALLWAY I-D UNISEX RM 136 STORAGE 172A STORAGE 131A VESTIBULE I-A STAIRWELL I-C STAIRWELL I-B OFFICE 142 HALLWAY 1-U STAIRWELL 1-V BDF 138 STAIRWELL 1-S STAIRWELL 1-H STAIRWELL 1-E ELEVATOR 1-J 09.27 09.27 ACT-01: 2' x 2' LAY-IN ACOUSTICAL TILE & SUSPENSION SYSTEM, RE: FINISH SCHEDULE CEILING LEGEND TYPE A1 5/8" GYPSUM BOARD (PAINTED PNT-01 UNLESS NOTED ON PLAN) ON METAL STUD. TYPE B1 5/8" GYPSUM BOARD (PAINTED PNT-01 UNLESS NOTED ON PLAN) ON METAL SUSPENSION SYSTEM. TYPE B2 EXPOSED STRUCTURE. PAINT PNT-02, RE: FINISH LEGEND TYPE E-1 NOTE: ALL DROPS NEED TO BE NON-COMBUSTIBLE METAL FRAMING OR LIGHT GAUGE METAL FRAMING AND MEET L/360 STANDARD FOR ALLOWABLE DEFLECTION. ACCOUSTIC FOAM ON 5/8" GYPSUM BOARD ON METAL SUSPENSION SYSTEM. TYPE B3 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A131 LEVEL 01 RCP PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 01 REFLECTED CEILING PLAN GENERAL NOTES - CEILING 1 VERIFY ALL MECHANICAL DUCT, GRILLE, DIFFUSER, AND VENT LOCATIONS WITH MECHANICAL DRAWINGS 2 CEILING GRID SHOWN IS ONLY A GRAPHIC REPRESENTATION OF CEILING. CEILING PATTERN IS TO BE CENTERED IN THE ROOM, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL VERIFY ACTUAL GRID LAYOUT/LOCATION 3 VERIFY AND COORDINATE ALL MECHANICAL DUCT, GRILL DIFFUSER & LOCATIONS, VENTS, AND QUANTITY WITH MECHANICAL PLANS 4 VERIFY ALL LIGHTS, SMOKE DETECTORS, AND EXIT DEVICE LOCATIONS AND QUANTITIES WITH ELECTRICAL DRAWINGS. SEE ARCHITECTURE FOR LIGHT LAYOUT LOCATION. LIGHT FIXTURES TO BE CENTERED AND SYMMETRICALLY LOCATED IN UNITS AND SHARED SPACES UNLESS NOTED OTHERWISE 5 PROVIDE DEFLECTION TRACKS AT TOP OF ALL COLD FORMED METAL FRAMING; SEE SHEET SERIES AE500 6 MAKE FACTORY EDGE WHERE TILE IS CUT TYPICAL FOR ALL LAY-IN ACOUSTICAL TILE WITH REGULAR EDGE 7 SEE SHEET SERIES A600 FOR FINISH MATERIAL SPECIFICATIONS 8 VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES A400's. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS 9 ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS KEYED NOTES 09.27 REPLACE, PATCH AND REPAIR CEILING AS NEEDED. RE: FINISH SCHEDULE FOR PAINT. A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 INSTRUMENT RM 203A CHEMISTRY STOCK RM 213 OFFICE 213A CLASSROOM 270 CLASSROOM 268 MEN'S RM 266 WOMEN'S RM 264 OFFICE 252 OFFICE 253 OFFICE 250 OFFICE 248 OFFICE 246 OFFICE 244 OFFICE 242 OFFICE 240 OFFICE 238 WORK ROOM 243 OFFICE 236 OFFICE 234 OFFICE 239 OFFICE 237 OFFICE 235 OFFICE 233 OFFICE 232 CLASSROOM 255 CLASSROOM 277 OFFICE 259 OFFICE 261 OFFICE 263 OFFICE 265 MEN'S ROOM 226 WOMEN'S ROOM 220 GENERAL CHEM LAB 282 CHEM STOCK RM 282A OFFICE 286 OFFICE 285 OFFICE 289 OFFICE 290 OFFICE 291 OFFICE 292 OFFICE 294 OFFICE 296 OFFICE 298 CHEMISTRY LAB 204 CHEMISTRY LAB 214 CHEMISTRY LAB 210 CHEMISTRY PREP RM 281 CLASSROOM 276 CUST RM 267 BDF RM 280 CUST RM 228 INSTRUMENT RM 203B CLASSROOM 229 CLASSROOM 279 CLASSROOM 297 CLASSROOM 299 CHEMISTRY LAB 203 STORAGE 258 STORAGE RM 277A WORK ROOM 287A SEC/ RECEP RM 287 HALLWAY 2-U HALLWAY 2-D HALLWAY 2-F HALLWAY 2-S LOUNGE 2-V HALLWAY 2-J HALLWAY 2-M SECRETARY/RECEPTION RM 230 HALLWAY 2-K CLASSROOM 260 CLASSROOM 262 HALLWAY 2-L CUST STOR 216 STAIRWELL 2-HELEVATOR 2-G STAIRWELL 2-T HALLWAY 2-B STAIRWELL 2-A STAIRWELL 2-C BIO-CHEMISTRY LAB 272 A1 9' - 0" 23.04 B3 A514 ________________TYP 26.11 09.27 23.01 TYP 26.01 TYP 26.01 TYP 26.12 TYP 26.06TYP TYP 23.04 26.15 23.01 A1 A514 ________________ 08.04 ACT-01: 2' x 2' LAY-IN ACOUSTICAL TILE & SUSPENSION SYSTEM, RE: FINISH SCHEDULE CEILING LEGEND TYPE A1 5/8" GYPSUM BOARD (PAINTED PNT-01 UNLESS NOTED ON PLAN) ON METAL STUD. TYPE B1 5/8" GYPSUM BOARD (PAINTED PNT-01 UNLESS NOTED ON PLAN) ON METAL SUSPENSION SYSTEM. TYPE B2 EXPOSED STRUCTURE. PAINT PNT-02, RE: FINISH LEGEND TYPE E-1 NOTE: ALL DROPS NEED TO BE NON-COMBUSTIBLE METAL FRAMING OR LIGHT GAUGE METAL FRAMING AND MEET L/360 STANDARD FOR ALLOWABLE DEFLECTION. ACCOUSTIC FOAM ON 5/8" GYPSUM BOARD ON METAL SUSPENSION SYSTEM. TYPE B3 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A132 LEVEL 02 RCP PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 02 REFLECTED CEILING PLAN GENERAL NOTES - CEILING 1 VERIFY ALL MECHANICAL DUCT, GRILLE, DIFFUSER, AND VENT LOCATIONS WITH MECHANICAL DRAWINGS 2 CEILING GRID SHOWN IS ONLY A GRAPHIC REPRESENTATION OF CEILING. CEILING PATTERN IS TO BE CENTERED IN THE ROOM, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL VERIFY ACTUAL GRID LAYOUT/LOCATION 3 VERIFY AND COORDINATE ALL MECHANICAL DUCT, GRILL DIFFUSER & LOCATIONS, VENTS, AND QUANTITY WITH MECHANICAL PLANS 4 VERIFY ALL LIGHTS, SMOKE DETECTORS, AND EXIT DEVICE LOCATIONS AND QUANTITIES WITH ELECTRICAL DRAWINGS. SEE ARCHITECTURE FOR LIGHT LAYOUT LOCATION. LIGHT FIXTURES TO BE CENTERED AND SYMMETRICALLY LOCATED IN UNITS AND SHARED SPACES UNLESS NOTED OTHERWISE 5 PROVIDE DEFLECTION TRACKS AT TOP OF ALL COLD FORMED METAL FRAMING; SEE SHEET SERIES AE500 6 MAKE FACTORY EDGE WHERE TILE IS CUT TYPICAL FOR ALL LAY-IN ACOUSTICAL TILE WITH REGULAR EDGE 7 SEE SHEET SERIES A600 FOR FINISH MATERIAL SPECIFICATIONS 8 VERIFY CEILING HEIGHTS IN UNITS WITH SHEET SERIES A400's. CONTRACTOR TO VERIFY AND MAXIMIZE CEILING HEIGHT IN ALL AREAS DEPENDENT ON DUCTWORK LOCATIONS 9 ELECTRICIAN SHALL NOT SET ANY CEILING J-BOXES THAT ARE FOR LIGHTS BEFORE THE FINAL LOCATION OF THE DROPPED SOFFITS HAVE BEEN DETERMINED. THIS WILL ENSURE THAT THE LIGHTS THAT NEED TO BE CENTERED ARE CORRECTLY CENTERED BETWEEN THE SOFFITS KEYED NOTES 08.04 BID ALTERNATE 1 - ROLLER WINDOW SHADES IN THE BIO-CHEMISTRY LAB 272 09.27 REPLACE, PATCH AND REPAIR CEILING AS NEEDED. RE: FINISH SCHEDULE FOR PAINT. 23.01 MECHANICAL DUCT, RE: MECHANICAL 23.04 BID ALTERNATE 2 - SNORKEL IN BIO-CHEMISTRY LAB 272, INCLUDING DUCTS TO SNORKELS. USE LABS-USA FX2 EXHAUST SNORKEL CHEM MODEL AS BASIS OF DESIGN. LENGTH OF ARM, MOUNTING STYLE, AND HOOD TYPE TBD. RE: MECHANICAL EXHAUST. 26.01 LIGHT FIXTURE, RE: ELECT. 26.06 DUPLEX POWER RECEPTACLE, RE: ELECTRICAL 26.11 ELECTRICAL POWER AND DATA CEILING PANEL, RE: ELECTRICAL 26.12 TELEVISION, OFOI. RE: RCP AND DETAIL 26.15 WALL MOUNTED CLOCK. RE: ELECTRICAL DRAWINGS CASEWORK TAG101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES C D E 4 5 6 A411AE5 A411BB2 B1 A411B E5 E1E4 E3 D1 E1 COMPUTER LAB 59 EQUIP / CHECK OUT 59A PHOTO STUDIO 51 STORAGE 59B OFFICE 57 OFFICE 55 DARK ROOM 59D VESTIBULE 59C FILM 59E STORAGE 51A E2 A411A D3 A411B D2 C1 D1D4 A411AD4 A411A D5 A411B E3 A411B C3 C4 A411BB4 CHANGING 51BB3 A411AC5A411AC5 MI R 22.05 26.08 A411A D4 (OPP) 10.26 10.23 10.22 (ABOVE) 24 " 1' - 2 " 48" 36" 24 " 24" 09.29 09.29 09.30 IN BACKGROUND 34"90" 4' - 0 " E1 A581 ________________ 59A.1 51.1 RE: FLOOR PLAN BACKGROUND 34 " 11.14 33"30"30"30"30"30"30"FILLER 212212 212 212 212 212 212 59C PL-01 PL-02 WB-02 34 " FILLER 30"30"30"30"30"30" 26.15 212 212 212 212 212 212 06.03 PL-02 PL-01 WB-02 5' - 0 " IN BACKGROUND CL EQEQ 11.04 59.1 59.2 10.25 4' - 0 " 18"9" CL 2' - 11 7/8" 5' - 0 " CL 59A.2 E1 A581 ________________ 4' - 0 " 10.25 E1 A581 ________________ 18"9" CL EQ EQ 34 " SS-01 D3 A581 ________________ 1. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK. 2. DO NOT SCALE DRAWINGS 3. RE: SHEET G011 FOR TYPICAL MOUNTAIN HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL- MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT. 4. UPPER, LOWER, AND TALL CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE. 5. UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYP. 6. ALL ELECTRICAL AND DATA OUTLETS ABOVE COUNTER TOPS SHOULD BE MOUNTED HORIZONTALLY 7. PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES AND WASTE LINES 8. PROVIDE ALUMINUM EDGE MOLDING @ ALL TILE TO H.M. DOOR TRANSITIONS 9. PROVIDE METAL TRIM AT ALL OUTSIDE EDGES ON TILE WALLS. RE: FINISH SCHEDULE 10. PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS. RE: FINISH SCHEDULE 11. ALL EXPOSED STEEL COLUMNS TO BE PAINTED TO MATCH ADJACENT WALL 12. ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE 13. COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. IF SHOWN IN ELEVATION, PROVIDE 4" BACKSPLASH 14. ALL WOOD GRAIN TO RUN VERTICALLY, UNLESS NOTED OTHERWISE 15. CALLED OUT RESTROOM ACCESSORIES TO BE INSTALLED AT EVERY STALL 16. ALL SIGNAGE, LETTERING, GRAPHICS TO BE COORDINATED WITH OWNER PER CAMPUS GRAPHIC STANDARDS 17. PROVIDE MILLWORK LOCKS WITH CAMPUS STANDARD LOCKS WHERE INDICATED WITH LOCK SYMBOL AT MILLWORK ELEVATION GENERAL NOTES OPEN TO BEYOND 34 " 48"48" 250 250 PL-01 PL-02 WB-02 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A411A ENLARGED PLANS AND INTERIOR ELEVATIONS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set KEYED NOTES 06.03 TECH STATION, OFOI 09.29 LEVEL 5 WALL FINISH. WALL TO RECEIVE PHOTO BACKDROP PAINT, RE: FINISH SCHEDULE 09.30 PAINT ELECTRICAL PANEL, PNT-01, RE: FINISH SCHEDULE 10.22 RE-USED EXISTING BLACKOUT CURTAIN AND CEILING TRACK, CFCI 10.23 BACKDROP CANVAS CURTAIN AND CEILING TRACK, CFCI. ENSURE THAT THEY ARE STRUCTURALLY AND SEISMICALLY SUPPORTED. 10.25 MARKER BOARD, 4'X4', OFCI 10.26 RE-INSTALL POWER PAPER ROLLER, RE: ELECTRICAL PLANS. 11.04 FLAT PANEL TV, OFCI, 3/4" BLOCKING AT ALL LOCATIONS 11.14 LARGE ROUND WASTE BIN 22.05 FLOOR SINK, RE: PLUMBING 26.08 LIGHT INDICATOR, RE: ELECTRICAL 26.15 WALL MOUNTED CLOCK. RE: ELECTRICAL DRAWINGS PL-01 PLASTIC LAMINATE, CABINETS, RE: FINISH SCHEDULE PL-02 PLASTIC LAMINATE, COUNTERTOP, RE: FINISH SCHEDULE SS-01 EPOXY RESIN COUNTERTOP, RE: FINISH SCHEDULE WB-02 WALL BASE, RE: FINISH SCHEDULE 1/4" = 1'-0"A1 LEVEL 00 ENLARGED FLOOR PLAN- PHOTOGRAPHY LAB 1/4" = 1'-0"E1 COMPUTER LAB 59 - NORTH 1/4" = 1'-0"E3 COMPUTER LAB 59 - EAST 1/4" = 1'-0"E5 COMPUTER LAB 59 - SOUTH 1/4" = 1'-0"D1 COMPUTER LAB 59 - WEST 1/4" = 1'-0"D3 EQUIP / CHECK OUT 59A - EAST 1/4" = 1'-0"D4 OFFICE 55 - SOUTH 1/4" = 1'-0"D5 FILM 59E - NORTH 1/4" = 1'-0"C5 COMPUTER LAB 59 - ISLAND CASEWORK TAG101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES 26.15 34 " OPEN TO BEYOND FILLER 33"30"30"36" END PANEL END PANEL 16" 212 212 212 152 10.06 SS-01 PL-01 WB-02 10.31 TYP (6) WB-01WB-02 PNT-01 COLUMN 36"36"36"FILLER 250250212 36 " SS-01 PL-01WB-02 10.31TYP (3) FILLER 40"40"40"40"FILLER 31"31"31"31"A581 C1 C3 A581 ________________ SS-01 PL-01 WB-02 250250 36 " A2 A581 ________________ 61 " 101" 22.11 PL-01 CL EQ EQ 5' - 0 " CL CL EQ EQ CL EQ EQ 11.04 11.0911.09 26.01 B1 A514 B2 A514 51.2 51B 51A WB-03WB-01WB-01 09.29 PNT-04 06.03 51.1 WB-03 WB-01 09.29 PNT-04 59A.2 E1 A581 ________________ 48 " 7' - 6"7' - 2" D2 A581 ________________ 20 " 16 " 16 " 16 " 247" 51A FILLER 48"44"48"FILLER 402402402 PL-01 WB-02 OPEN TO BEYOND 77" D3 A581 ________________ 36"36"FILLER 30 " 24 " 30 " 302302 C-13 PL-02 PL-01 34 " 6" FILLER 30"33"FILLER 212 152 10.06 10.01 PL-02 PL-01 WB-02 26.01 CLCL1' - 4"1' - 1" 10.03 4' - 0 " E1 A581 ________________ 1' - 2"1' - 6" 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A411B INTERIOR ELEVATIONS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set GENERAL NOTES - INTERIOR ELEVATIONS 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE DRAWINGS 3 RE: SHEET SERIES G000 FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT 4 UPPER, LOWER, AND TALL MILLWORK CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE 5 UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYPICAL 6 ALL ELECTRICAL AND DATA OUTLETS ABOVE COUNTER TOPS SHOULD BE HORIZONTALLY ALIGNED AND MOUNTED HORIZONTALLY 7 PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES AND WASTE LINES 8 PROVIDE METAL TRIM AT ALL OUTSIDE EDGES ON TILE WALLS; SEE DETAILS AND FINISH SCHEDULE 9 PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS; SEE DETAILS AND FINISH SCHEDULE 10 ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE 11 RE ACCESSORY SCHEDULE FOR WHO PROVIDES RESTROOM ACCESSORIES 12 RE: SHEET A700 SERIES FOR MATERIAL SPECIFICATIONS 13 RE: SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES 14 RE: SHEET SERIES A600 FOR DOOR AND WINDOW TYPES 15 RE: SHEET SERIES A500 FOR CASEWORK DETAILS KEYED NOTES 06.03 TECH STATION, OFOI 09.29 LEVEL 5 WALL FINISH. WALL TO RECEIVE PHOTO BACKDROP PAINT, RE: FINISH SCHEDULE 10.01 MIRROR, RE: ACCESSORY SCHEDULE 10.03 SOAP DISPENSER, RE: ACCESSORY SCHEDULE 10.06 PAPER TOWEL DISPENSER, RE: ACCESSORY SCHEDULE 10.31 CABINET LOCK. RE: HARDWARE SCHEDULE 11.04 FLAT PANEL TV, OFCI, 3/4" BLOCKING AT ALL LOCATIONS 11.09 WHITE BOARD, OFOI, CONTRACTOR TO PROVIDE BLOCKING 22.11 PHOTO PROCESSING SINK, RE: PLUMBING 26.01 LIGHT FIXTURE, RE: ELECT. 26.15 WALL MOUNTED CLOCK. RE: ELECTRICAL DRAWINGS PL-01 PLASTIC LAMINATE, CABINETS, RE: FINISH SCHEDULE PL-02 PLASTIC LAMINATE, COUNTERTOP, RE: FINISH SCHEDULE PNT-01 PAINTED GYP, RE: FINISH SCHEDULE PNT-04 PAINTED GYP, RE: FINISH SCHEDULE SS-01 EPOXY RESIN COUNTERTOP, RE: FINISH SCHEDULE WB-01 WALL BASE, RE: FINISH SCHEDULE WB-02 WALL BASE, RE: FINISH SCHEDULE WB-03 WALL BASE, RE: FINISH SCHEDULE 1/4" = 1'-0"E1 DARK ROOM 59D - NORTH 1/4" = 1'-0"E2 DARK ROOM 59D - EAST ONE 1/4" = 1'-0"E3 DARK ROOM 59D - EAST TWO 1/4" = 1'-0"E4 DARK ROOM 59D - SOUTH 1/4" = 1'-0"E5 DARK ROOM 59D - WEST 1/4" = 1'-0"D1 PHOTO STUDIO 51 - NORTH 1/4" = 1'-0"D2 PHOTO STUDIO 51 - EAST 1/4" = 1'-0"D4 PHOTO STUDIO 51 - SOUTH 1/4" = 1'-0"C1 PHOTO STUDIO 51 - WEST 1/4" = 1'-0"C3 STORAGE 51A - EAST 1/4" = 1'-0"C4 STORAGE 51A - WEST 1/4" = 1'-0"B1 STORAGE 59B - NORTH 1/4" = 1'-0"B2 STORAGE 59B - SOUTH 1/4" = 1'-0"B4 CHANGING 51B - SOUTH 1/4" = 1'-0"B3 CHANGING 51B - EAST B 6 7 A412 E2 E1 D1 E4 A412D4 D8 D3 PHYSICS LAB 52 ACOUSTICS STUDIO 52B STORAGE 52C OPTICS LAB 52A A412 C3 C1 C2 2' - 0 " 2'-0" 1' - 8 " 22.18 22.18 22.17 14 " 1' - 2" 1' - 2 " 1' - 2 " 1' - 2 " 1' - 2 " 2' - 0 " 3' - 3 " 14" 09.24 CASEWORK TAG101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES 52.2 22.17 05.15 26.13 52C 52.1 34 " 211 117"20"30"33" 212 152 RE: FLOOR PLAN IN FOREGROUND PL-01 SS-01 A2 A581 ________________ PL-01 20 " 16 " 16 " 16 " 60 " 16 " A2 A581 ________________ PL-01 WB-02 52B 05.15 26.13 60 " 16 " 137 1/8" A2 A581 ________________ PL-01 PL-01 TYP 60 " 16 " 132 1/8"25 7/8"132 1/8"47 7/8"162"16 1/4" A2 A581 ________________ TYP D2 A581 ________________ 72 " 16 " 72" PL-01 10.25 CL EQ EQ 4' - 8 " CL 72" D2 A581 ________________ 54 " 16 " 54" 417 PL-01 D2 A581 ________________ 20 " 16 " 16 " 16 " D2 A581 ________________ 20 " 16 " 16 " 16 " 52C 16"D2 A581 ________________ 20 " 16 " 16 " 16 " 1. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK. 2. DO NOT SCALE DRAWINGS 3. RE: SHEET G011 FOR TYPICAL MOUNTAIN HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL- MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT. 4. UPPER, LOWER, AND TALL CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE. 5. UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYP. 6. ALL ELECTRICAL AND DATA OUTLETS ABOVE COUNTER TOPS SHOULD BE MOUNTED HORIZONTALLY 7. PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES AND WASTE LINES 8. PROVIDE ALUMINUM EDGE MOLDING @ ALL TILE TO H.M. DOOR TRANSITIONS 9. PROVIDE METAL TRIM AT ALL OUTSIDE EDGES ON TILE WALLS. RE: FINISH SCHEDULE 10. PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS. RE: FINISH SCHEDULE 11. ALL EXPOSED STEEL COLUMNS TO BE PAINTED TO MATCH ADJACENT WALL 12. ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE 13. COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. IF SHOWN IN ELEVATION, PROVIDE 4" BACKSPLASH 14. ALL WOOD GRAIN TO RUN VERTICALLY, UNLESS NOTED OTHERWISE 15. CALLED OUT RESTROOM ACCESSORIES TO BE INSTALLED AT EVERY STALL 16. ALL SIGNAGE, LETTERING, GRAPHICS TO BE COORDINATED WITH OWNER PER CAMPUS GRAPHIC STANDARDS 17. PROVIDE MILLWORK LOCKS WITH CAMPUS STANDARD LOCKS WHERE INDICATED WITH LOCK SYMBOL AT MILLWORK ELEVATION GENERAL NOTES 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A412 ENLARGED PLANS AND INTERIOR ELEVATIONS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set KEYED NOTES 05.15 ANGLE IRON AIR TANK SUPPORT BY CFCI, BASIS OF DESIGN: GLOBAL INDUSTRIES WALL MOUNT 3 CYLINDER BRACKET 09.24 ADD ALTERNATE 4 - 4" PREMIUM ACCOUSTIC FOAM PANELS APPLIED TO WALLS AND CIELING OF THE ACCOUSTICS LAB 52B4 10.25 MARKER BOARD, 4'X4', OFCI 22.17 EMERGENCY SHOWER AND EYE WASH STATION, RE: PLUMBING 22.18 EXISTING FLOOR DRAIN, RE: PLUBMING 26.13 CABLE TRAY BELOW THE LAY-IN CEILING. MOUNT TO THE FLOOR DECK ABOVE AT 9'-0" AFF. DESIGN STRURCTURAL LOAD FOR 5LBS PER SQUARE FOOT. PL-01 PLASTIC LAMINATE, CABINETS, RE: FINISH SCHEDULE SS-01 EPOXY RESIN COUNTERTOP, RE: FINISH SCHEDULE WB-02 WALL BASE, RE: FINISH SCHEDULE 1/4" = 1'-0"1 LEVEL 00 ENLARGED FLOOR PLAN - PHYSICS 1/4" = 1'-0"E1 PHYSICS LAB 52 - NORTH 1/4" = 1'-0"E2 PHYSICS LAB 52 - EAST 1/4" = 1'-0"E4 PHYSICS LAB 52 - SOUTH 1/4" = 1'-0"D1 PHYSICS LAB 52 - WEST 1/4" = 1'-0"D3 OPTICS LAB 52A - NORTH 1/4" = 1'-0"D4 OPTICS LAB 52A - SOUTH 1/4" = 1'-0"D8 OPTICS LAB 52A - WEST 1/4" = 1'-0"C1 STORAGE 52C - EAST 1/4" = 1'-0"C2 STORAGE 52C - SOUTH 1/4" = 1'-0"C3 STORAGE 52C - WEST 1. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK. 2. DO NOT SCALE DRAWINGS 3. RE: SHEET G011 FOR TYPICAL MOUNTAIN HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL- MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT. 4. UPPER, LOWER, AND TALL CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE. 5. UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYP. 6. ALL ELECTRICAL AND DATA OUTLETS ABOVE COUNTER TOPS SHOULD BE MOUNTED HORIZONTALLY 7. PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES AND WASTE LINES 8. PROVIDE ALUMINUM EDGE MOLDING @ ALL TILE TO H.M. DOOR TRANSITIONS 9. PROVIDE METAL TRIM AT ALL OUTSIDE EDGES ON TILE WALLS. RE: FINISH SCHEDULE 10. PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS. RE: FINISH SCHEDULE 11. ALL EXPOSED STEEL COLUMNS TO BE PAINTED TO MATCH ADJACENT WALL 12. ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE 13. COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. IF SHOWN IN ELEVATION, PROVIDE 4" BACKSPLASH 14. ALL WOOD GRAIN TO RUN VERTICALLY, UNLESS NOTED OTHERWISE 15. CALLED OUT RESTROOM ACCESSORIES TO BE INSTALLED AT EVERY STALL 16. ALL SIGNAGE, LETTERING, GRAPHICS TO BE COORDINATED WITH OWNER PER CAMPUS GRAPHIC STANDARDS 17. PROVIDE MILLWORK LOCKS WITH CAMPUS STANDARD LOCKS WHERE INDICATED WITH LOCK SYMBOL AT MILLWORK ELEVATION GENERAL NOTES CASEWORK TAG101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES 1 C D E 2 3 A413D3 A413 E1A413D1 C4 E4 BIO-CHEMISTRY LAB 272 22.17 A413 E3 A413D4 36"36" 36"36" 31" 30" 26.16 26.16 A601 C1 A1 A601 A2 A601 A601 B2 A601 B3 33"33" C A S E W O R K M A T C H E X I S T I N G 100 100 26.1226.1226.12 02.42 10.06 10.06WV-01 SS-01 WB-02 10.30 26.0626.06 26.0602.41 02.41 02.40 33.03 6.05 21.02 26.15 4 2 " FILLER 33"33"33"33" 212 212 212 272 05.15 SS-01 PL-01 WB-02 10.31 TYP (6) OPEN TO BEYOND 63"36" 3 4 " 100 100 23.0523.0402.43 02.42 WV-01 SS-01WB-02 22.16 02.4102.40 3 0 " 37"37"37"37"37" 100 100 100 26.1226.1226.12 09.28 WB-02 SS-01 SS-01 PL-01 OPEN KNEE SPACE OPEN KNEE SPACE 10.30 A2 A601 B2 A601 B3 A601 A1 A514 ________________ 3 4 " 18"63"18" 230230 SF1 3 '-5 1 /2 " 3 '-6 1 /2 " 4'-0" 10.06 36 3/4"23" WB-02OPEN KNEE SPACE PL-01 SS-01 A2 A581 ________________PL-01 10.31 TYP (2) A601 C6 33"33"33"33" END PANEL FILLER FOREGROUND 4 2 " OPEN TO BEYOND 272 212 212 212 10.25 CLEQ EQ SS-01 PL-01 OPEN TO BEYOND WB-02 10.31 TYP (6) C-13 C-13 272 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A413 ENLARGED PLANS AND INTERIOR ELEVATIONS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set KEYED NOTES 02.40 EXISTING AIR AND GAS LINES TO REMAIN. 02.41 EXISTING CUP SINK AND FAUCET TO REMAIN. 02.42 EXISTING COUNTERTOP AND UNDERCOUNTER CABINETS TO REMAIN. 02.43 EXISTING UPPER SHELVING TO REMAIN. 05.15 ANGLE IRON AIR TANK SUPPORT BY CFCI, BASIS OF DESIGN: GLOBAL INDUSTRIES WALL MOUNT 3 CYLINDER BRACKET 6.05 NEW COUNTERTOP AND BACKSPLASH 09.28 NEW SOLID SURFACE WINDOW SILL, RE: FINISH SCHEDULE 10.06 PAPER TOWEL DISPENSER, RE: ACCESSORY SCHEDULE 10.25 MARKER BOARD, 4'X4', OFCI 10.30 WALL MOUNTED FIRE EXTINGUISHER 10.31 CABINET LOCK. RE: HARDWARE SCHEDULE 21.02 FIRE BLANKET CABINET, RE: CODE REVIEW PLAN. VERIFY LOCATION WITH OWNER PRIOR TO PLACEMENT. 22.16 SINK, RE: PLUMBING 22.17 EMERGENCY SHOWER AND EYE WASH STATION, RE: PLUMBING 23.04 BID ALTERNATE 2 - SNORKEL IN BIO-CHEMISTRY LAB 272, INCLUDING DUCTS TO SNORKELS. USE LABS-USA FX2 EXHAUST SNORKEL CHEM MODEL AS BASIS OF DESIGN. LENGTH OF ARM, MOUNTING STYLE, AND HOOD TYPE TBD. RE: MECHANICAL EXHAUST. 23.05 RELOCATED EXISTING FUME HOODS, RE: MECHANICAL 26.06 DUPLEX POWER RECEPTACLE, RE: ELECTRICAL 26.12 TELEVISION, OFOI. RE: RCP AND DETAIL 26.15 WALL MOUNTED CLOCK. RE: ELECTRICAL DRAWINGS 26.16 OUTLETS ON THE BACK OF CASEWORK. COORDINATE WITH ELECTRICAL. 33.03 NEW AIR AND GAS LINES AND NOZZLES PL-01 PLASTIC LAMINATE, CABINETS, RE: FINISH SCHEDULE SS-01 EPOXY RESIN COUNTERTOP, RE: FINISH SCHEDULE WB-02 WALL BASE, RE: FINISH SCHEDULE WV-01 WOOD VENEER, CABINETS, RE: FINISH SCHEDULE 1/4" = 1'-0"1 LEVEL 02 ENLARGED FLOOR PLAN - BIO-CHEMISTRY LAB 1/4" = 1'-0"E1 BIO-CHEMISTRY LAB 272 - NORTH ONE 1/4" = 1'-0"E3 BIO-CHEMISTRY LAB 272 - NORTH TWO 1/4" = 1'-0"E4 BIO-CHEMISTRY LAB 272 - EAST 1/4" = 1'-0"D1 BIO-CHEMISTRY LAB 272 - SOUTH ONE 1/4" = 1'-0"D3 BIO-CHEMISTRY LAB 272 - SOUTH TWO 1/4" = 1'-0"D4 BIO-CHEMISTRY LAB 272 - SOUTH THREE 1/4" = 1'-0"C4 BIO-CHEMISTRY LAB 272 - WEST CASEWORK TAG101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES 11.09 11.09 12' - 0"12' - 0"1' - 10 1/2" 4 ' - 8 " CL4' - 0 " 10.24 26.01 EQEQ 4 ' - 0 " 4 ' - 8 " CL11.09 11.09 26.01 4 ' - 0 " CL EQ EQ CL EQ EQ 4 ' - 8 " CL 50 11.09 11.09 11.09 11.09 12' - 0"6' - 0"1' - 7 1/2" 4 ' - 0 " 4 ' - 8 " CL 10.24 B3 A514 ________________ 26.01 300M 5 4 " 5 4 " 25" PL-01 OPEN TO BEYOND 55 57 59.2 59.1 69 09.3021.01 4 4 1 /2 " 02.2710.06 3 4 " 152 SS-01WV-01 40"36"24"24"24"24"24"24"24"FILLERFILLER24"24"24"24"24"24"24" A1 A581 ________________A1 A581 ________________WB-0210.31 TYP (16) A4 A581 ________________ 22.01 FRP-01 5 ' - 0 " 3' - 0" 22.19 4 ' - 0 " CL 1' - 10" 10.33 5 ' - 0 " 3' - 0" 22.01 FRP-01 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A414 INTERIOR ELEVATIONS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set GENERAL NOTES - INTERIOR ELEVATIONS 1 GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK 2 DO NOT SCALE DRAWINGS 3 RE: SHEET SERIES G000 FOR TYPICAL MOUNTING HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL-MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT 4 UPPER, LOWER, AND TALL MILLWORK CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE 5 UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYPICAL 6 ALL ELECTRICAL AND DATA OUTLETS ABOVE COUNTER TOPS SHOULD BE HORIZONTALLY ALIGNED AND MOUNTED HORIZONTALLY 7 PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES AND WASTE LINES 8 PROVIDE METAL TRIM AT ALL OUTSIDE EDGES ON TILE WALLS; SEE DETAILS AND FINISH SCHEDULE 9 PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS; SEE DETAILS AND FINISH SCHEDULE 10 ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE 11 RE ACCESSORY SCHEDULE FOR WHO PROVIDES RESTROOM ACCESSORIES 12 RE: SHEET A700 SERIES FOR MATERIAL SPECIFICATIONS 13 RE: SHEET SERIES A500 FOR WALL AND ASSEMBLY TYPES 14 RE: SHEET SERIES A600 FOR DOOR AND WINDOW TYPES 15 RE: SHEET SERIES A500 FOR CASEWORK DETAILS KEYED NOTES 02.27 EXISTING UPPER CABINETS TO REMAIN AND TO BE PROTECTED DURING CONSTRUCTION. 09.30 PAINT ELECTRICAL PANEL, PNT-01, RE: FINISH SCHEDULE 10.06 PAPER TOWEL DISPENSER, RE: ACCESSORY SCHEDULE 10.24 CEILING MOUNTED PROJECTOR, OFCI 10.31 CABINET LOCK. RE: HARDWARE SCHEDULE 10.33 MOP/BROOM HOLDER, OFOI 11.09 WHITE BOARD, OFOI, CONTRACTOR TO PROVIDE BLOCKING 21.01 FIRE EXTINGUISHER CABINET, RE: CODE REVIEW PLAN. VERIFY LOCATION WITH OWNER PRIOR TO PLACEMENT. 22.01 MOP SINK, RE: PLUMBING 22.19 CHEMICAL STATION, RE: PLUMBING 26.01 LIGHT FIXTURE, RE: ELECT. FRP-01 FIBER REINFORCED PANEL, RE: FINISH SCHEDULE PL-01 PLASTIC LAMINATE, CABINETS, RE: FINISH SCHEDULE SS-01 EPOXY RESIN COUNTERTOP, RE: FINISH SCHEDULE WB-02 WALL BASE, RE: FINISH SCHEDULE WV-01 WOOD VENEER, CABINETS, RE: FINISH SCHEDULE 1/4" = 1'-0"E1 CLASSROOM 50 - NORTH 1/4" = 1'-0"E2 CLASSROOM 50 - EAST 1/4" = 1'-0"E4 CLASSROOM 50 - SOUTH 1/4" = 1'-0"D1 CLASSROOM 50 - WEST 1/4" = 1'-0"D2 VESTIBULE 0-H - NORTH 1/4" = 1'-0"C1 HALLWAY 0-C - EAST 1/4" = 1'-0"D3 PHYSICAL GEOLOGY ROOM 158 - EAST 1/4" = 1'-0"B1 CUST RM 68 - SOUTH 1/4" = 1'-0"B2 CUST RM 68 - WEST E F 4 5 MEN'S RM 134 UNISEX RM 136 WOMEN'S RM 132 A415E3 E1 E4 E2 A415D4 E5 C1 D2 A415 D1 D3 D5 C2 A415 C4 C5 B2 B3 A415 C3B1 F 5 A415D4 SI M E5 SI M D2SIM C1 SIM A415 C2 SIM D3SIM D5 SI M D1 SI M A415B2 SI M B3 SIM C4 SI M C5SIM A415 C3 SI M B1 SI M 1. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS, OR CONFLICTS IN THE DRAWINGS BEFORE BEGINNING WORK. 2. DO NOT SCALE DRAWINGS 3. RE: SHEET G011 FOR TYPICAL MOUNTAIN HEIGHTS. PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL- MOUNTED ITEMS WHETHER BLOCKING IS DEPICTED IN DRAWINGS OR NOT. 4. UPPER, LOWER, AND TALL CABINETS NOT TO EXCEED 36" IN WIDTH, UNLESS NOTED OTHERWISE. 5. UNLESS NOTED OTHERWISE, MATCH UPPER CABINET WIDTH DIMENSIONS TO BASE CABINETS - TYP. 6. ALL ELECTRICAL AND DATA OUTLETS ABOVE COUNTER TOPS SHOULD BE MOUNTED HORIZONTALLY 7. PROVIDE SAFETY INSULATION ON ALL EXPOSED SUPPLY WATER LINES AND WASTE LINES 8. PROVIDE ALUMINUM EDGE MOLDING @ ALL TILE TO H.M. DOOR TRANSITIONS 9. PROVIDE METAL TRIM AT ALL OUTSIDE EDGES ON TILE WALLS. RE: FINISH SCHEDULE 10. PROVIDE METAL TRIM AT ALL TILE TO FLOOR TRANSITIONS. RE: FINISH SCHEDULE 11. ALL EXPOSED STEEL COLUMNS TO BE PAINTED TO MATCH ADJACENT WALL 12. ALL MILLWORK INTERIOR FINISH TO BE WHITE MELAMINE, UNLESS NOTED OTHERWISE 13. COUNTERTOP EDGE PROFILES TO BE SQUARE EDGE. IF SHOWN IN ELEVATION, PROVIDE 4" BACKSPLASH 14. ALL WOOD GRAIN TO RUN VERTICALLY, UNLESS NOTED OTHERWISE 15. CALLED OUT RESTROOM ACCESSORIES TO BE INSTALLED AT EVERY STALL 16. ALL SIGNAGE, LETTERING, GRAPHICS TO BE COORDINATED WITH OWNER PER CAMPUS GRAPHIC STANDARDS 17. PROVIDE MILLWORK LOCKS WITH CAMPUS STANDARD LOCKS WHERE INDICATED WITH LOCK SYMBOL AT MILLWORK ELEVATION GENERAL NOTES CASEWORK TAG101M AWS STANDARD CASEWORK TYPE MODIFIED CASEWORK TYPE REFER TO CASEWORK DESIGN SERIES (CDS) OF THE ARCHITECTURAL WOODWORK STANDARDS (AWS) FOR A FULL DESCRIPTION OF CASEWORK TYPES 5 ' - 4 " CLCL 2' - 9 1/2"0' - 9 1/2" E6 A571 ________________ E4 A571 ________________TL-02 TL-03 PNT-01 10.10 10.16 10.05 10.29 5 ' - 4 " D138 E6 A571 ________________ E4 A571 ________________ TL-03 TL-02 PNT-01 5 ' - 4 " E6 A571 ________________ E4 A571 ________________ TL-03 TL-02 PNT-01 CL 4' - 6" 10.06 2 4 " 6 " 3 4 " 1' - 6 1/2" 5 ' - 4 " CL E6 A571 ________________ E4 A571 ________________TL-02 TL-03 PNT-01 10.27 10.02 22.03 22.16 10.28 CL 2' - 6" 10.03 5 ' - 4 " 1' - 5 3/8"3' - 1" CL CL RE: FLOOR PLAN IN FOREGROUND 22.03 10.27 TYP (2) TYP (2) TL-02 TL-03 E6 A571 ________________ E5 A571 ________________ E4 A571 ________________ PNT-01 OPEN TO BEYOND 5 ' - 4 " E5 A571 ________________ E6 A571 ________________ E4 A571 ________________ TL-03 TL-02 PNT-01 CL 1' - 10 1/2" 10.06 RE: FLOOR PLAN IN BACKGROUND E4 A571 ________________ E6 A571 ________________ E5 A571 ________________ TL-03 TL-02 PNT-01 10.05 5 ' - 4 " D304 E4 A571 ________________ E6 A571 ________________ TL-03 TL-02 PNT-01 OPEN TO BEYOND 5 ' - 4 " E6 A571 ________________ E5 A571 ________________ E4 A571 ________________ TL-03 TL-02 PNT-01 5 ' - 4 " 3 4 " 6 " 2 4 " CLCL 1' - 2 15/16"2' - 8 1/4" E4 A571 ________________ E5 A571 ________________ E6 A571 ________________ TL-03 TL-02 PNT-01 10.28 22.16 TYP (2) TYP (2) CL2' - 7" 10.03 5 ' - 4 " E6 A571 ________________ E5 A571 ________________ E4 A571 ________________ PNT-01 TL-03 TL-02 CL 1' - 0" 10.03 OPEN TO BEYOND 5 ' - 4 " E6 A571 ________________ E5 A571 ________________ E4 A571 ________________ PNT-01 TL-03 TL-02 5 ' - 4 " E4 A571 ________________ E6 A571 ________________ PNT-01 TL-03 TL-02 OPEN TO BEYOND 3 4 " 6 " 2 4 " CLCL 2' - 0 1/4"1' - 11 1/4" E4 A571 ________________ E5 A571 ________________E5 A571 ________________ E6 A571 ________________ PNT-01 TL-03 TL-02 10.28 22.16 TYP (2) TYP (2) CL0' - 8" 5 ' - 4 " 2' - 6 1/4" CL D307 E4 A571 ________________ E6 A571 ________________ E5 A571 ________________ PNT-01 TL-02 10.05 CL0' - 10" 10.03 OPEN TO BEYOND 5 ' - 4 " E6 A571 ________________ E4 A571 ________________ E5 A571 ________________E5 A571 ________________ TL-03 TL-02 PNT-01 1' - 5 1/2"3' - 0"3' - 1" CL CLCL 5 ' - 4 " E6 A571 ________________ E4 A571 ________________TL-02 TL-03 PNT-01 10.27 22.03 TYP (3) TYP (3) 5 ' - 4 " 2' - 7 1/8" CL E5 A571 ________________ E4 A571 ________________ E6 A571 ________________ TL-03 TL-02 PNT-01 10.05 CL2' - 2" 10.06 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A415 RESTROOM ENLARGED PLANS AND INTERIOR ELEVATIONS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set1/4" = 1'-0"A1 LEVEL 01 ENLARGED FLOOR PLAN - RESTROOMS 1/4" = 1'-0"A3 LEVEL 02 ENLARGED FLOOR PLAN - RESTROOMS KEYED NOTES 10.02 36" GRAB BAR, RE: ACCESSORY SCHEDULE 10.03 SOAP DISPENSER, RE: ACCESSORY SCHEDULE 10.05 TOILET PAPER DISPENSER, RE: ACCESSORY SCHEDULE 10.06 PAPER TOWEL DISPENSER, RE: ACCESSORY SCHEDULE 10.10 42" GRAB BAR, RE: ACCESSORY SCHEDULE 10.16 18" VERTICAL GRAB BAR, RE: ACCESSORY SCHEDULE 10.27 WALL MOUNTED TOILET SEAT PROTECTOR, OFCI 10.28 18"X24" WALL MOUNTED FRAMELES MIRROR, RE: ACCESSORY SCHEDULE 10.29 SANITARY NAPKIN DISPOSAL, RE: ACCESSORY SCHEDULE 22.03 TOILET FIXTURE, RE: PLUMBING 22.16 SINK, RE: PLUMBING PNT-01 PAINTED GYP, RE: FINISH SCHEDULE TL-02 GENERAL WALL TILE TL-03 ACCENT WALL TILE 1/4" = 1'-0"E1 UNISEX RM 136 - NORTH 1/4" = 1'-0"E2 UNISEX RM 136 - EAST 1/4" = 1'-0"E3 UNISEX RM 136 - SOUTH 1/4" = 1'-0"E4 UNISEX RM 136 - WEST 1/4" = 1'-0"E5 MEN'S RM 134 - NORTH ONE 1/4" = 1'-0"D1 MEN'S RM 134 - NORTH TWO 1/4" = 1'-0"D2 MEN'S RM 134 - EAST ONE 1/4" = 1'-0"D3 MEN'S RM 134 - EAST TWO 1/4" = 1'-0"D4 MEN'S RM 134 - SOUTH ONE 1/4" = 1'-0"D5 MEN'S RM 134 - SOUTH TWO 1/4" = 1'-0"C1 MEN'S RM 134 - WEST ONE 1/4" = 1'-0"C2 MEN'S RM 134 - WEST TWO 1/4" = 1'-0"C3 WOMEN'S RM 132 - NORTH ONE 1/4" = 1'-0"C4 WOMEN'S RM 132 - NORTH TWO 1/4" = 1'-0"C5 WOMEN'S RM 132 - EAST 1/4" = 1'-0"B1 WOMEN'S RM 132 - SOUTH ONE 1/4" = 1'-0"B2 WOMEN'S RM 132 - SOUTH TWO 1/4" = 1'-0"B3 WOMEN'S RM 132 - WEST LAYERS LEGEND SA = GYPSUM BOARD BOTH SIDE OF CORE SB = GYPSUM BOARD ONE SIDE OF CORE SF = GYPSUM BOARD, ONE LAYER CORE SIDE, ONE LAYER PLYWOOD SIDE SH = GYPSUM BOARD, ONE LAYER HAT CHANNEL SIDE SG = GYPSUM BOARD, ONE LAYER CORE SIDE, ONE LAYER HAT CHANNEL SIDE NON-FIRE RATED WALL TAG (description) SA6a CORE MATERIAL (SEE LEGEND) LAYERS (SEE LEGEND) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) FIRE RATED WALL TAG (description) FIRE RATING 1 SA6 a CORE MATERIAL (SEE LEGEND) LAYERS (SEE LEGEND) CORE SIZE (ROUNDED; SEE LEGEND) HEAD CONDITION MODIFIER (IF APPLICABLE) CORE SIZE LEGEND C = CONCRETE WALLS, MASONRY S = STEEL STUDS CORE MATERIAL LEGEND WALL TYPE HEAD CONDITION LEGEND IF NULL = TYPICAL PARTITION FLOOR TO FLOOR/CEILING/ROOF a = PARTITION EXTEND FROM FLOOR TO 6" ABOVE CEILING (SEE E4/A501) b = ACOUSTIC PARTITION (SEE E5/A501) c = 1 - HR FIRE RATED PARTITION d = 2 - HR FIRE RATED PARTITION STEEL STUDS 1 =A7/8" 3 = 2 1/2" 4 = 3 5/8" 6 = 6" 8 = 8" SUPERSCRIPT NOTES - A - HAT CHANNEL FURRING IN LIEU OF METAL STUD B - IF WALL IS STRUCTURAL, DO NOT TAG WALL OR INCLUDE IN WALL TYPES GYP BOARD SCHEDULE 5/8" GYPSUM BOARD 5/8" TYPE X GYPSUM BOARD 5/8" MOISTURE RESISTANCE AND MOLD- RESISTANT GYPSUM BOARD (TYPE X WHERE FIRE RATED) 5/8" GLASS MAT MOISTURE AND MOLD-RESISTANT GYPSUM TILE BACKER (TYPE X WHERE FIRE RATED) 5/8" CEMENT BOARD ALL PARTITIONS UNLESS NOTED OTHERWISE BELOW FIRE RATED PARTITIONS WET OR HIGH HUMIDITY, HEAVY MOISTURE EXPOSURE AREAS SUCH AS TOILET ROOMS, SHOWERS, LOCKER ROOMS, AND JANITOR CLOSETS, EXCEPT WHERE WALL TILE OCCURS. USE AT KITCHEN WALLS FROM FLOOR TO 12" ABOVE COUNTERTOP, EXCEPT WHERE TILE BACKSPLASH OCCURS. LIMITED WATER EXPOSURE AREAS WHERE WALL TILE OCCURS, BEHIND FIBERGLASS SHOWER ENCLOSURES, AND KITCHEN WALLS FROM FLOOR TO 12" ABOVE COUNTERTOP WHERE TILE BACKSPLASH OCCURS WET OR HIGH HUMIDITY, HEAVY MOISTURE EXPOSURE AREAS WHERE WALL TILE OCCURS, EXCEPT AT BACKSPLASHES 1. AT FIRE RATED PARTITIONS WHERE CEMENT BOARD IS REQUIRED, PROVIDE CEMENT BOARD ON TOP OF TYPE X GYPSUM BOARD, OR PROVIDE A TESTED FIRE-RESISTANCE DESIGN THAT ALLOWS REPLACEMENT OF THE TYPE X GYPSUM BOARD WITH CEMENT BOARD. 2. REFER TO THE ENVIRONMENTAL CLASSIFICATIONS IN THE CURRENT EDITION OF THE TILE COUNCIL OF NORTH AMERICA HANDBOOK FOR CERAMIC, GLASS AND STONE TILE INSTALLATION. GYP BOARD NOTES STEEL FRAMING (RE: CORE SIZE LEGEND) STEEL FRAMING (RE: CORE SIZE LEGEND) SEALANT (BOTH SIDES) RUNNER TRACK INSULATION TYPE AS INDICATED IN SCHEDULE SILL PLAN FIRE RATING: SEE SCHEDULE SOUND RATING (STC): SEE SCHEDULE UL DESIGN NUMBER: SEE SCHEDULE INTERIOR PARTITION SA_ 5/8" GYP. BOARD, TYPE X, BOTH SIDES STEEL FRAMING (RE: CORE SIZE LEGEND) STEEL FRAMING (RE: CORE SIZE LEGEND) SEALANT RUNNER TRACK INSULATION TYPE AS INDICATED IN SCHEDULE SILL PLAN FIRE RATING: SEE SCHEDULE SOUND RATING (STC): SEE SCHEDULE UL DESIGN NUMBER: SEE SCHEDULE INTERIOR PARTITION SB_ 5/8" GYP. BOARD, TYPE X 1/2" FOR SB2 WALL TYPE HOLD FRAMING 1/2" OFF OF EXISISTING WALL TO LEAVE A MINIMUM OF 3" BETWEEN EXISTING WALL FACE AND INSIDE FACE OF STUDS. 3" MIN. CONCRETE MASONRY UNITS WITH REINFORCING PER STRUCTURAL SOLID GROUTED MASONRY SILL PLAN FIRE RATING: SEE SCHEDULE SOUND RATING (STC): SEE SCHEDULE UL DESIGN NUMBER: SEE SCHEDULE INTERIOR PARTITION CD_ CEILING AS SCHEDULED, REFER TO REFLECTED CEILING PLAN CONTINUOUS DEFLECTION TRACK AND INNER SLIP TRACK SCHEDULED WALL STUD BRACING TO STRUCTURE/DECK (ABOVE) AT 6' O.C. (ALTERNATING) WALL TYPE VARIES PER 1 3/4 MIN 2 MAX SOUND ATTENUATION BATT AS APPLICABLE 0 ' - 6 " ACOUSTIC SEALANT (BOTH SIDES) IF APPLICABLE INNER SLIP TRACK SCHEDULED WALL CONTINUOUS DEFLECTION TRACK SOUND ATTENUATION BATT AS APPLICABLE SCHEDULED FLOOR/CEILING/ROOF STEEL FRAMING (RE: CORE SIZE LEGEND) STEEL FRAMING (RE: CORE SIZE LEGEND) SEALANT (BOTH SIDES) RUNNER TRACK INSULATION TYPE AS INDICATED IN SCHEDULE SILL PLAN FIRE RATING: SEE SCHEDULE SOUND RATING (STC): SEE SCHEDULE UL DESIGN NUMBER: SEE SCHEDULE INTERIOR PARTITION SF_ 5/8" GYP. BOARD, TYPE X, BOTH SIDES 3/4" FIRE TREATED SHEATHING SILL PLAN INSULATION TYPES AS INDICATED IN SCHEDULE SEALANT BOTTOM TRACK 5/8" GYP. BOARD, TYPE X, BOTH SIDES STEEL FRAMING (RE: CORE SIZE LEGEND) STEEL FRAMING (RE: CORE SIZE LEGEND) RESILIENT CHANNEL @ 16" O.C., U.N.O., (RE: LEGEND) FIRE RATING: SEE SCHEDULE SOUND RATING (STC): SEE SCHEDULE UL DESIGN NUMBER: SEE SCHEDULE INTERIOR PARTITION SH_ SILL PLAN INSULATION TYPE AS INDICATED IN SCHEDULE SEALANT (BOTH SIDES) BOTTOM TRACK 5/8" GYP. BOARD, TYPE X STEEL FRAMING (RE: CORE SIZE LEGEND) STEEL FRAMING (RE: CORE SIZE LEGEND) RESILIENT CHANNEL @ 16" O.C., U.N.O., (RE: LEGEND) FIRE RATING: SEE SCHEDULE SOUND RATING (STC): SEE SCHEDULE UL DESIGN NUMBER: SEE SCHEDULE INTERIOR PARTITION SG_ 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A501 WALL ASSEMBLIES - INTERIOR 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set GENERAL NOTES - PARTITIONS 1. REFER TO DIMENSION PLANS FOR WALL TYPE LOCATIONS 2. REFER TO SCHEDULES & DETAILS FOR FINISHES. WALL TYPES REFER TO BASE WALL ONLY. 3. "LINE OF STRUCTURE" AS SHOWN AT THE HEAD CONDITIONS OF EACH WALL TYPE IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE THE EXACT CONSTRUCTION CONDITION. RATED WALLS ARE TO TERMINATE AT STRUCTURAL MEMBERS WITH A FIRE RESISTANT RATING. WHERE REQ'D APPROPRIATE FRAMING AND GYP BOARD IS TO BE INSTALLED AND OFFSET AROUND STRUCTURAL MEMBERS OR OTHER OBSTRUCTIONS SUCH AS PIPING OR DUCTWORK, TO MAINTAIN THE FIRE RESISTANCE RATING. NON-RATED WALLS THAT CONTINUE TO STRUCTURE ARE TO TERMINATE AT PROPER LOCATIONS TO MAINTAIN THE INTENT OF THE CONTINUOUS PLANE OF ONE LAYER OF GYP BOARD AS A NOISE, SMOKE OR OTHER TYPE OF BARRIER. 4. SPACING OF THE METAL STUDS HAS NOT BEEN INDICATED ON THE WALL TYPES OR DETAILS. REFER TO STRUCTURAL STUD DETAILS SHEET 5. ALL GYP BOARD SHALL BE 5/8", U.N.O. 6. REFER TO GYP BOARD SCHEDULE BELOW FOR GYP BOARD REQUIREMENTS PER LOCATION AND WALL TYPE 7. ALL WALL ASSEMBLIES TO BE FILLED W/ SOUND ATTENUATION BATTS, U.N.O. 8. VARYING INSULATION REQUIREMENTS HAVE NOT BEEN INDICATED ON THE WALL TYPES; FOR WALL TYPES WITH VARYING INSULATION TYPES, REFERENCE INSULATION PLAN 9. VARYING LOAD BEARING REQUIREMENTS HAVE NOT BEEN INDICATED ON THE WALL TYPES; FOR WALL TYPES WITH VARYING LOAD BEARING REQUIREMENTS, REFERENCE LOAD BEARING PLAN 10. SOUND ATTENUATION BLANKETS/BATTS SHALL EXTEND THE FULL HEIGHT OF THE WALLS, U.N.O. 11. THERMAL AND SOUND INSULATION AND COVERING WHICH ARE INSTALLED IN CONCEALED AND EXPOSED SPACES AND AS COVERING OVER PIPE AND TUBING SHALL BE TESTED IN ACCORDANCE WITH AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) E 84 AND HAVE A FLAME SPREAD OF 0-25 AND A SMOKE INDEX OF 0-450. 12. SUPPORT INSULATION WITH CHICKEN WIRE IN PARTITIONS WITHOUT GYP BOARD ON BOTH SIDES TO STRUCTURE. 13. ALL RATED WALLS SHALL BE CONSTRUCTED FIRST. SECONDARY WALLS TO ABUT, BUT NOT PENETRATE RATED WALLS. 14. FIRESTOPPING TO BE PROVIDED AT PENETRATIONS THROUGH RATED WALLS AS SPECIFIED. 15. UL DESIGN NUMBERS REFER TO FIRE RESISTANCE IN MOST CURRENT EDITION OF THE UL DIRECTORY. 16. PROVIDE ALL COMPONENTS REQUIRED PER THE INDICATED DESIGN NUMBER OR TEST REFERENCE LISTING NUMBER, INCLUDING BUT NOT LIMITED TO FASTENER SIZE AND SPACING. 17. APPROPRIATE SUBMITTAL INFORMATION MUST BE PROVIDED TO SUBSTANTIATE THAT THE MATERIALS AND ASSEMBLY USED BY THE CONTRACTOR HAVE BEEN TESTED BY A RECOGNIZED TESTING AGENCY TO MEET THE FIRE RESISTANCE RATING SCHEDULED ON THESE WALL TYPES. 18. MAINTAIN 1/2" SPACE BETWEEN FLOOR SLAB AND BOTTOM OF GYP BOARD ON ALL WALLS. 19. STOP STUD 1" BELOW METAL RUNNER (TOP TRACK) TO ALLOW FOR VERTICAL EXPANSION DO NOT ATTACH STUDS OR GYP BOARD TO TOP TRACK. 20. U.N.O. ALL WALLS TO BE LEVEL 4 FINISH 21. REFER TO INTERIOR DETAILS FOR ADDITIONAL INFORMATION. PARTITION TAG INSULATION TYPE FIRE RATING HEAD DETAIL STUD DEPTH CORE SIZE (NOM.) TOTAL THICKNESS FIRE TEST STC RATING 0|SA4|a NR E5/A501 3 5/8" 4 0' - 4 7/8" 0 NA 0|SA4|b GL. FIBER NR E6/A501 3 5/8" 4 0' - 4 7/8" 0 <varies> 0|SA4|a NA NR E5/A501 3 5/8" 4 0' - 4 7/8" 0 NA 0|SA4|b NA NR E6/A501 3 5/8" 4 0' - 4 7/8" 0 NA 0|SA6|<varies>GL. FIBER NR E6/A501 6" 6 0' - 7 1/4" NA NA 0|SA6|a NA NR E5/A501 6" 6 0' - 7 1/4" NA NA 0|SA6|b NA NR E6/A501 6" 6 0' - 7 1/4" NA NA NOTE: IF FIRE RATING IS BLANK, WALL IS NOT RATED. NOTE: IF FIRE RATING IS BLANK, WALL IS NOT RATED. PARTITION TAG INSULATION TYPE FIRE RATING HEAD DETAIL STUD DEPTH CORE SIZE (NOM.) TOTAL THICKNESS FIRE TEST STC RATING 0|SB1|a NA NR E5/A501 1 5/8" 1.5 0' - 2 1/4" 0 NA 0|SB3|b GL. FIBER NR E6/A501 2 1/2" 2.5 0' - 3 1/8" 0 NA 0|SB3|a NA NR E5/A501 2 1/2" 2.5 0' - 3 1/8" 0 NA 0|SB3|b NA NR E6/A501 2 1/2" 2.5 0' - 3 1/8" 0 NA 0|SB4|b GL. FIBER NR E6/A501 3 5/8" 4 0' - 4 1/4" 0 NA 0|SB4|a NA NR E5/A501 3 5/8" 4 0' - 4 1/4" 0 NA 0|SB6|a NA NR E5/A501 6" 6 0' - 6 5/8" 0 NA PARTITION TAG INSULATION TYPE FIRE RATING HEAD DETAIL CORE SIZE (NOM.)TOTAL THICKNESS LOAD BEARING FIRE TEST STC RATING CD6 0' - 5 5/8" 3" = 1'-0"E4 STEEL STUD PARTITION HEAD 6" ABOVE CEILING 3" = 1'-0"E5 TYPICAL STEEL STUD PARTITION HEAD PARTITION TAG INSULATION TYPE FIRE RATING HEAD DETAIL STUD DEPTH CORE SIZE (NOM.) TOTAL THICKNESS FIRE TEST STC RATING 0|SF6|b GL. FIBER NR E6/A501 6" 6 0' - 8" NA 45 NOTE: IF FIRE RATING IS BLANK, WALL IS NOT RATED. MATCH ADJACENT PARTITION TAG INSULATION TYPE FIRE RATING HEAD DETAIL STUD DEPTH CORE SIZE (NOM.) TOTAL THICKNESS FIRE TEST STC RATING 0|SH2|b GL. FIBER NR E6/A501 3 5/8" 4 0' - 4" NA NA PARTITION TAG INSULATION TYPE FIRE RATING HEAD DETAIL STUD DEPTH CORE SIZE (NOM.) TOTAL THICKNESS FIRE TEST STC RATING 0|SG4|b GL. FIBER NR E6/A501 3 5/8" 4 0' - 5 3/4" NA 60 NOTE: IF FIRE RATING IS BLANK, WALL IS NOT RATED.NOTE: IF FIRE RATING IS BLANK, WALL IS NOT RATED. EXISTING STRUCTURE UNISTRUT ATTACHED TO EXISTING STRUCTURE ABOVE 1 2 " PROJECTOR / TV MOUNT BY OWNER SCHEDULED CEILING RE: CEILING PLAN APROXIMATLEY 1 1/2" X 1 1/2" ANGLE IRON ATTACHED TO UNISTRUT 1 1/2" PIPE, THREADED ON THE END TO RECIEVE OWNER PROVIDED PROJECTOR / TV MOUNT 1 1/2" FITTING WELDED TO ANGLE IRON TO RECIEVE PIPE, PAINTED FINISH; PNT-01 9 0°FIRST LINE OF BRACING 6'-0" OR LESS FROM WALL BOUNDARY CEILING SUSPENSION SYSTEM WALL SPLAY WIRE COMPRESSION POST 1 2 '-0 " (M A X .) NOTE: AREAS SMALLER THAN 144 SQ. FT. AND WITH WALLS ON FOUR SIDES EXTENDING TO THE STRUCTURE NEED NOT BE BRACED. BOUNDARY WALLS MUST BE BRACED TOP AND BOTTOM INDEPENDENT OF CEILING TO QUALIFY. 1 2 ' - 0 " ( M A X . ) 6 '-0 " M A X . TYP. D1 A514 METAL FURRING CHANNEL @ 16" O.C. (TYP) FIRST LINE OF BRACING 4'-0" OR LESS FROM WALL BOUNDARY RUNNER CHANNEL @ 4'-0" O.C. (TYP) 4'-0" TYP. 1 2 '-0 " T Y P . NOTE: AREAS SMALLER THAN 144 SQ. FT. AND WITH WALLS ON FOUR SIDES, EXTENDING TO THE STRUCTURE, DO NOT NEED TO BE BRACED. BOUNDARY WALLS MUST BE BRACED TOP AND BOTTOM INDEPENDENT OF CEILING. 12'-0" TYP. TYP. D1 A514 NOTE 1- ALL SPLAY WIRES TO BE IN LINE WITH ATTACHED COMPONENT NOTE 2- ALL SPLAY WIRES TO BE TAUT AND TIED BOTH ENDS WITH MINIMUM OF THREE TURNS IN 1" OF RUN. NOTE 3- COMPLY WITH IBC 2015, ASTM C635, ASTM C636 AND CISCA STANDARDS NOTE 4- SPLAY WIRES SHALL ATTACH TO STRUCTURAL GIRDER OR JOIST ONLY, DO NOT ATTACH TO ROOF DECK. NOTE 5- METAL COMPRESSION POST (STRUT) FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. COMPRESSION POSTS & SPLAY WIRES TO BE INSTALLED EVERY 12' O.C. BOTH DIRECTIONS STARTING 6' FROM WALL. SEE COMPRESSION POST ALLOWABLE LENGTHS TABLE FOR SIZES. SEE DETAILS 3 & 4 FOR TYPICAL BRACING. NOTE 6- ALL LIGHT FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. WHEN INTERMEDIATE SYSTEMS ARE USED, ATTACH NO. 12 GAGE HANGERS TO THE GRID MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE. LIGHT FIXTURES WEIGHING LESS THAN 56 LBS. SHALL HAVE TWO NO. 12 GAGE HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. COMPLY WITH IBC 2015 NOTE 7- ALL LIGHT FIXTURES SHALL BE POSITIVELY ATTACHED 20 LBS. SHALL BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS. TERMINALS OR SERVICES WEIGHING 20 LBS., BUT NOT MORE THAT 56 LBS., SHALL IN ADDITION HAVE TWO NO. 12 GAGE HANGERS CONNECTED TO THE CEILING SYSTEM HANGERS OR TO THE STRUCTURE ABOVE. TERMINALS OR SERVICES WEIGHING MORE THAN 56 LBS. SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. COMPLY WITH IBC 2015 NOTE 8- ALL GRID SYSTEM IN SEISMIC ZONE D OR GREATER ARE REQUIRED TO BE HEAVY DUTY. REFER REQUIREMENTS TO ASCE 7 REQUIREMENTS. NOTE 9- CEILINGS WITHOUT RIGID BRACING MUST HAVE 2" OVERSIZED TRIM RINGS FOR SPRINKLERS AND OTHER PENETRATIONS, COORDINATE W/ SPECIFICATIONS. NOTE 10 - SUSPENDED ACOUSTIC CEILINGS INSTALLED IN SEISMIC DESIGN CATEGORY D SHALL BE INSTALLED ACCORDING TO IBC 808.1.1.1, IBC 1613.1, ASTM C 635, ASTCM C 636, AND ASCE 7-10. NOTE 11 - ACOUSTICAL PANEL CEILINGS REQUIRES SEISMIC DESIGN TO BE COMPLETED BY A LICENSE ENGINEER AND SUBMITTED FOR REVIEW AND APPROVAL. RE: SPECIFICATIONS. STRUCTURE SPLAY WIRE - SECURE TO STRUCTURE MAIN TEE CROSS TEE VERTICAL HANGER WIRE ADJACENT TO POST SPRING CLIP INSERTS IN HOLE IN POST STRUT ASSEMBLY TOP CLIP MECHANICALLY FASTENED TO DECK PER MANUFACTURERS RECOMMENDATIONS BULB CLIP ATTACHING COMPRESSION POST AND MAIN RUNNER MECHANICALLY FASTENED PER MANUFACTURERS RECOMMENDATIONS A FASTENER OR SPLAY WIRES MAYBE INSERTED INTO THE TAB OF THE POST AND THROUGH A CONVENIENCE HOLE IN THE MAIN TEE BULB COMPRESSION POST - INSTALL WITHIN 2" OF CROSS TEE INTERSECTION 45° OR LESS 45° OR LESS 45° OR LESS 45° OR LESS COMPRESSION POST ALLOWABLE LENGTHS TABLE 13/16" x 13/32" STRUT 19 GA MATERIAL TYP. ALLOWABLE LENGTH 24" 1 5/8" x 13/16" STRUT 12 GA 48" 13/16" x 13/16" STRUT 19 GA 54" 1 5/8" x 1" STRUT 12 GA 60" 3 5/8" x 1 1/4" STRUT 16 GA 82" 1 1/4" x 1 1/4" STRUT 14 GA 84" 1 5/8" x 1 3/8" STRUT 12 GA 96" 1 5/8" x 1 5/8" STRUT 12 GA 108" 1 5/8" x 2 7/16" STRUT 12 GA 120" NOTES 1. THE INFORMATION PROVIDED IS FOR QUICK REFERENCE ONLY. OTHER RESTRICTIONS AND EXEMPTIONS MAY APPLY. 2. WALL MOLDING SHOULD NOT BE USED AS STRUTS. 3. A STRUCTURAL ENGINEER SHOULD BE CONSULTED FOR LENGTHS GREATER THAT 14'. C R O S S T E E HEAVY DUTY MAIN RUNNER 12 GA. METAL HANGER WIRES HEAVY DUTY MAIN RUNNER 4'-0" TYPICAL 3" MAX., TYP. SLACK WIRES #12 WIRE HANGER AT EACH CORNER OF FIXTURE (TYP.) INDEPENDENT OF CEILING SUPPORT SYSTEM 12 GA. HANGER SEE SPECIFICATION 1 1/2" C.R. CHANNEL @ 48" O.C. 5/8" TYPE 'X' GYP BD 3/4" FURRING CHANNELS @ 24" O.C. 8" MAX8" MAX FASTENER ON ALL MEMBERS @ TWO ADJACENT WALLS ONLY PER MFG REQ. 7/8" SEISMIC CLIP BY MANUFACTURER SCHED. CEILING TILE CEILING GRID MAIN RUNNER OR CROSS TEE GRID PERPENDICULAR TO CEILING NOT ATTACHED TO CLOSURE ANGLE (TWO ADJACENT WALLS) HANGER 12 GA. @ 4'-0" O.C. MAX. NOTE 1 - ALL HANGER WIRES TO BE IN LINE WITH ATTACHED COMPONENT OR SHALL BE COUNTERSLOPED NOT GREATER THAN 1/6 NOTE 2 - ALL HANGER WIRES TO BE TAUT AND TIED BOTH ENDS W/ MIN. OF 4 TURNS IN 1" OF RUN. 0' - 8" MAX0' - 8" MAX SCREW INTO MOLDING AT PERIMETER ANGLE MOLDING BY MANUFACTURER SCHED. GYPSUM PANEL DRYWALL MAIN RUNNER OR CROSS TEE HANGER 12 GA. @ 4'-0" O.C. MAX. 1. ALL HANGER WIRES TO BE IN LINE WITH ATTACHED COMPONENT OR SHALL BE COUNTERSLOPED NOT GREATER THAN 1/6 2. ALL HANGER WIRES TO BE TAUT AND TIED BOTH ENDS W/ MIN. OF 4 TURNS IN 1" OF RUN. NOTE: SCHEDULED WALL - SEE FLOOR PLAN CEILING AS SCHEDULED BID ALTERNATE 1 - MANUAL ROLLER SHADE SYSTEM,(RS-01) RE: FINISH SCHEDULE. BREAK AT VERT. WINDOW MULLION. FASTEN PER MANUF. SPEC'S SNAPLOC FRONT FASCIA COVER: ARCH. TO SELECT FINISH COLOR FROM MANUF. STANDARD COLORS. EXISTING EXTERIOR STOREFRONT SYSTEM & GLAZING SA6 b 3" DRAPERY TRACK, ALUMINUM STRAIGHT TRACK, CEILING MOUNT, FINISH: MANUAL RIPPLEFOLD DRAPERY 3/4" PLYWOOD BACKER 6" FRAMED HEADER SCHEDULED WALL SEE PLAN C 6 B1 A514 B2 A514 SB 4 a SB 4 a SA 6 b 3" DRAPERY TRACK, ALUMINUM STRAIGHT TRACK, CEILING MOUNT, FINISH: MANUAL RIPPLEFOLD DRAPERY 3/4" PLYWOOD BACKER 6" FRAMED HEADER SA6 b 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A514 CEILING DETAILS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1 1/2" = 1'-0"B3 PROJECTER / TV POLE MOUNT 12" = 1'-0"A4 CEILING SEISMIC BRACING AT LAY-IN 12" = 1'-0"A6 CEILING SEISMIC BRACING GYP. 1 1/2" = 1'-0"C3 CEILING SEISMIC BRACING 1/64" = 1'-0"A2 TYP. CEILING FIXTURE SUPPORT 1 1/2" = 1'-0"A3 SUSPENDED CEILING CHANNEL DETAIL 1 1/2" = 1'-0"B5 LAY-IN CEILING DETAIL - CLIP ANGLE 1 1/2" = 1'-0"B6 TYP SUSP. GYP. BD. CLG. - CLIP ANGLE 3" = 1'-0"A1 MANUAL ROLLER SHADE DETAIL-SURFACE MOUNTED 3" = 1'-0"B1 BULK HEAD SECTION DETAIL 1 1 1/2" = 1'-0"C1 BULK HEAD CEILING DETAIL 3" = 1'-0"B2 BULK HEAD SECTION DETAIL 2 EXISTING CONCRETE FLOOR OVER DECK SCHEDULED FLOORING TS-04 TRANSITION RE: TRANSITION STRIP SCHEDULE CONCRETE FLOOR AS SCHEDULED SCHEDULED DOOR, AS OCCURS. EXISTING CONCRETE FLOOR OVER DECK FLOORING AS SCHEDULED TS-03 TRANSITION, RE: TRANSITION STRIP SCHEDULE SCHEDULED DOOR, AS OCCURS. MORTAR BED OVER CRACK ISOLATION SINGLE COMPONENT GROUT SCHEDULED FLOOR TILE EXISTING CONCRETE FLOOR OVER DECK METAL COVE TS-01 RE: TRANSITION STRIP SCHEDULE MORTAR BED OVER CRACK ISOLATION SINGLE COMPONENT GROUT PORCELAIN FLOOR TILE SCHEDULED WALL FINISH SCHEDULED. WALL TILE, RE: FINISH PLAN THINSET LATEX-PORTLAND CEMENT MORTAR BOND COAT WALL AS SCHED. SEE FLOOR PLAN FOR TYPE TYPE 7 TRANSITION RE: TRANSITION STRIP SCHEDULE SCHEDULED. WALL TILE, RE: FINISH PLAN SINGLE COMPONENT GROUT 1 7 /8 " BACKER BOARD TRANSITION STRIP,TS-03 ; RE: TRANSITION SCHEDULE SCHEDULED WALL TL-02; RE: FINISH SCHEDULE PAINTED GYP. SEE ELEVATION FOR FINISH EXISTING CONCRETE FLOOR OVER DECK FLOORING AS SCHEDULED TS-05 TRANSITION RE: TRANSITION STRIP SCHEDULE FLOORING AS SCHEDULED SCHEDULED DOOR, AS OCCURS. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A571 INTERIOR DETAILS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 3" = 1'-0"E1 CARPET TO CONCRETE TRANSITION 3" = 1'-0"E2 TILE TO CARPET 3" = 1'-0"E4 METAL COVE BASE - TITLE TO TILE 3" = 1'-0"E5 TILE TO TILE TO OUTSIDE CORNER 3" = 1'-0"E6 TILE EDGE DETAIL 3" = 1'-0"D1 CARPET TO SHEET VINYL TRANSITION 0' - 3" 0 ' - 4 " RE : E L E V A T I O N S 0 ' - 4 " 24" RE : E L E V A T I O N S RE : E L E V A T I O N S 12" SCHEDULED FINISH FLOOR; RE: FINISH FLOOR PLANS LOWER CABINET; RE: ELEVATION FOR CABINET TYPE WALL AS SCHEDULED; RE: PLAN FOR TYPE UPPER CABINET, RE: ELEVATION FOR CABINET TYPE BACKSPLASH WHERE OCCURS, RE: ELEVATION, SAME MATERIAL AS COUNTERTOP, CALKING AT JOINTS TO MATCH COUNTERTOP MATERIAL BASE TO MATCH MILLWORK MATERIAL UNLESS NOTED IN ELEVATIONS RE: PLAN VIEW VARIES SHELF: 3/4" PLYWOOD WITH WHITE MELAMINE FINISH, UNO. RE: INTERIOR ELEVATIONS. ALL EDGES TO HAVE MATCHING PVC EDGEBANDING KV 185 WHITE (WH) DOUBLE BRACKETS, COORDINATING BRACKET PER SHELF DEPTH, RE: PLAN VIEW FOR SHELF DEPTH PROVIDE 3/4" PLYWOOD SHEATHING FOR BACKING/BLOCKING WALL BASE AS SCHEDULED, RE: FINISH PLAN FINISHED FLOOR R E : E L E V A T I O N WALL AS SCHEDULED, RE: PLAN VIEW KV 85 WHITE (WH) SERIES STANDARDS, COORDINATING STANDARD PER OVERALL SHELVING HEIGHT, RE: ELEVATION FOR SHELVING HEIGHTS WALL AS SCHEDULED; SEE FLOOR PLAN FOR WALL TYPES FINISHED FLOOR COUNTERTOP: 3/4" PLYWOOD SUBSTRATE, RE: ELEVATION FOR FINISH TYPE BASE AS SPECIFIED. SEE ELEVATION FULL CONCEALED STEEL SUPPORT BRACKET. FINISH TO MATCH ADJACENT WALL COLOR/FINISH (WHERE EXPOSED). FINISH ALSO TO MATCH ADJACENT WALL COLOR/FINISHED FOR EXPOSED BRACKET ON EXISTING WALLS. 1' - 10"0' - 2" 4" BACKSPLASH WHERE OCCURS, RE: ELEVATION, MATERIAL TO MATCH COUNTERTOP MATERIAL, ADHERED TO WALL WITH CALKING AT WALL JOINT 2' - 0" CALKING AT JOINT TO MATCH WALL FINISH WALL AS SCHEDULED, RE: PLAN VIEW 1/2" THICK, MDF, EASED EDGES, PAINTED PNT-01; RE: FINISH SCHEDULE COAT HOOK, RE: ACCESSORY SCHEDULERE: E L E V A T I O N S 0 ' - 4 1 /2 " 4 8 " 36" 2 8 3 / 4 " 0 ' - 9 1 1 /1 6 " 0 ' - 9 3 /3 2 " 12" 1 5 3 /4 " DIVIDER: 3/4" PLYWOOD SUBSTRATE. FACED WITH PLASTIC LAMINATE (PL-01) WALL AS SCHEDULED; SEE FLOOR PLAN FOR WALL TYPES CALKING AT JOINT TO MATCH WALL FINISH COUNTERTOP RE: INTERIOR ELEVATIONS FOR FINISH. COUNTERTOP SUPPORT BRACKET 1" 4 8 " ELEVATION SECTION WALL AS SCHEDULED, RE: PLAN VIEW COUNTERTOP: 3/4" PLYWOOD SUBSTRATE WITH PENOLIC RESIN FINISH, SQUARE, EASED EDGE - SCRIBE TIGHTLY TO WALL, MATCHING 4" BACKSPLASH WHERE OCCURS. RE: ELEVATIONS FOR FINISH TYPE. REMOVABLE DRYING SHELF: WIRE MESH ATTACHED TO 3/4" PLYWOOD. REMOVABLE DRYING SHELF: 3/4" PLYWOOD PLASTIC LAMINATE WRAPPED. RE: ELEVATIONS FOR FINISH TYPE. RUBBER BASE, WB-02. RE: FINISH SCHEDULE SIDE PANEL, BLACK MELAMINE FINISH CABINET 3/4" PLYWOOD W/ PLASTIC LAMINATE, RE: ELEVATIONS FOR FINISH TYPE. 3/4" RAIL FOR DRYING SHELVES TO REST ON. WHITE MELAMINE FINISH 3" 4 " 3 6 " E Q 1 1 /2 " E Q T Y P 3 /4 " E Q E Q E Q E Q 36" 1/2" FIXED PLYWOOD SHELF 1/2" PLYWOOD DRAWER GLIDES *REFER TO EXISTING CASEWORK FOR DIMENSIONS. IF THERE ARE ANY DISCREPENCIES IN CONSTRUCTION, MATCH THE EXISTING CABINETS. 1 /4 " CARPET INSET, EM-01, RE: FINISH SCHEDULE RUBBER BASE, WB-02, RE: FINISH SCHEDULE FINISHED FLOOR, RE: FLOOR PLAN CABINET HARDWARE TO MATCH EXISTING HARDWARE LOCK, OLYMPUS LOCKS PER CAMPUS STANDARD 4 4 1 /2 " EXISTING WALL TEFLON MATERIAL, MAKE FLUSH WITH CARPET SQUARE COUNTERSUNK SCREW 1" 3/4" MDF WITH BULL NOSE EDGES. WOOD VENEER FINISH, WV-01, RE:FINISH SCHEDULE 3/4" SOLID WOOD OAK DRAWERS. SCREWED TOGETHER. T Y P 3 1 /2 " T Y P 4 1 /8 " BACKSPLASH. SS-01 0 ' - 4 " 0' - 0 3/4" RE: PLAN VIEW VARIES SHELF: 3/4" PLYWOOD WITH, WITH A 3/4" LIP. PL-01 FINISH, UNO. RE: INTERIOR ELEVATIONS. ALL EDGES TO HAVE MATCHING PVC EDGEBANDING KV 185 WHITE (WH) DOUBLE BRACKETS, COORDINATING BRACKET PER SHELF DEPTH, RE: PLAN VIEW FOR SHELF DEPTH PROVIDE 3/4" PLYWOOD SHEATHING FOR BACKING/BLOCKING WALL BASE AS SCHEDULED, RE: FINISH PLAN FINISHED FLOOR R E : E L E V A T I O N WALL AS SCHEDULED, RE: PLAN VIEW KV 85 WHITE (WH) SERIES STANDARDS, COORDINATING STANDARD PER OVERALL SHELVING HEIGHT, RE: ELEVATION FOR SHELVING HEIGHTS 1 " 1/2" FIXED PLYWOOD SHELF RUBBER BASE, WB-02, RE: FINISH SCHEDULE FINISHED FLOOR, RE: FLOOR PLAN EXISTING WALL CABINET: WOOD VENEER FINISH, WV-01, RE:FINISH SCHEDULE CABINET HARDWARE TO MATCH EXISTING HARDWARE LOCK, OLYMPUS LOCKS PER CAMPUS STANDARD 26 1/4" 3 4 " EXISTING COLUMN BEYOND OPEN CAVITY COUNTERTOP: 3/4" PLYWOOD SUBSTRATE WITH PHENOLIC RESIN FINISH, SQUARE, EASED EDGE - SCRIBE TIGHTLY TO WALL, MATCHING 4" BACKSPLASH WHERE OCCURS. RE: ELEVATIONS FOR FINISH TYPE. APRON FRONT 4 " 2 3 3 /4 " 4 1 /2 " 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A581 CASEWORK DETAILS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1 1/2" = 1'-0"C5 TYPICAL CASEWORK DETAIL 1 1/2" = 1'-0"D2 TYPICAL ADJUSTABLE SHELVING DETAIL 1 1/2" = 1'-0"D3 COUNTERTOP WITH SUPPORT BRACKET 3" = 1'-0"E1 MOUNTED COAT HOOK SECTION 1 1/2" = 1'-0"C1 PHOTO DIVIDER DETAIL 1 1/2" = 1'-0"C3 DRYING RACK CABINET 1 1/2" = 1'-0"A1 GEOLOGY ROCK STORAGE 1 1/2" = 1'-0"A2 TYPICAL CHEMICAL SHELVING DETAIL 1 1/2" = 1'-0"A4 GEOLOGY CABINET PAINTED HOLLOW METAL FRAME. DOOR SEALANT, EACH SIDE T Y P E S R E : W A L L PAINTED HOLLOW METAL FRAME. DOOR SEALANT, EACH SIDE TYPES RE: WALL HEADER, RE: STRUCTURAL SCHEDULED WALL F1 2"SEE SCHED.2" S E E D O O R S C H E D U L E 2 " HOLLOW METAL F2 HOLLOW METAL 2"SEE SCHED. 2" 2' - 0"2" S E E D O O R S C H E D U L E 2 " G1 FROSTED FILM ON THE INSIDE OF THE GLASS 2 "1 '-1 0 " 4 '-0 " 1"1" F3 ALUM STOREFRONT 2" S E E D O O R S C H E D U L E 2 " G1 2'-0" 7 '-2 " SEE SCHED.2"2" B5 A601 ________________ A4 A601 ________________ A5 A601 ________________ WOOD FLUSH D2 S E E S C H E D . SEE SCHED. C .L . O F H A R D W A R E 3 ' - 4 " WOOD FLUSH D3 S E E S C H E D . SEE SCHED. C .L . O F H A R D W A R E 3 ' - 4 " 6"6" 2 '-4 " 6 " G1 G1 4 '-0 " 2 '-0 " 1"1" FROSTED FILM ON THE INSIDE OF THE GLASS AT OFFICES ONLY HOLLOW METAL DOUBLE DOOR D5 V E R I F Y W / E X I S T I N G VERIFY W/ EXIST VERIFY W/ EXIST V E R I F Y W / E X I S T 3 ' - 4 " WOOD FLUSH DOUBLE DOOR D6 V E R I F Y W / E X I S T I N G VERIFY W/ EXIST VERIFY W/ EXIST V E R I F Y W / E X I S T 3 ' - 4 " ALUMINUM D1 S E E S C H E D . SEE SCHED. 6 " 5 " 2 ' - 3 " 1 0 " C .L . O F H A R D W A R E 3 ' - 4 " 6" G1 6" WOOD FLUSH D4 S E E S C H E D . SEE SCHED. C .L . O F H A R D W A R E 3 ' - 4 " 6" 5 '-6 " 6 " G1 HOLLOW METAL D7 S E E S C H E D . SEE SCHED. C .L . O F H A R D W A R E 3 ' - 4 " 6" SCHEDULED WALL, SEE WALL TYPES INSULATION TO EXTEND TO DECK STOREFRONT SYSTEM, RE: SPECIFICATIONS SEALANT BOTH SIDES TYP. SHIM BOX HEADER GYP BOARD "J" BEAD (BOTH SIDES) SCHEDULED WALL GLAZING, SEE WINDOW TYPES & GLAZING SCHEDULE SEALANT BOTH SIDES TYP. STOREFRONT SYSTEM SHIM GYP BOARD BACKER ROD & SEALANT BOTH SIDES TYPICAL SHIM SPACE FINISHED FLOOR WINDOW / STOREFRONT SYSTEM, SPECIFICATIONS PROVIDE MATCHING ALUMINUM 'L' STRIP TO STOREFRONT, TO COVER EXISTING TRAVERTINE WHERE OCCURS GENERAL NOTES -STOREFRONT A. WINDOW TYPES KEY: SF# (STORE FRONT SYSTEM) : 2" X 4 1/2" (B.O.D. = KAWNEER TRIFAB VERSAGLAZE 451T) B. UNLESS OTHERWISE SPECIFIED, MAX GLASS PANEL WIDTH SIZE SHALL NOT BE GREATER THAN 5'-0", ALL GLASS PANEL WIDTHS SHALL BE EQUAL. C. OVERALL DIMENSIONS ARE FROM OUTSIDE FACE OF MULLION; INTERIOR/FIELD DIMENSIONS ARE TO CENTERLINE OF MULLION D. PROVIDE TEMPERED GLASS AT ALL CODE REQUIRED LOCATIONS E. CONTRACTOR SHALL BE THE RESPONSIBLE PARTY FOR THE ENERGY PERFORMANCE RATINGS OF THE FENESTRATION SYSTEM IN ACCORDANCE WITH THE NATIONAL FENESTRATION RATING COUNCIL REQUIREMENTS. CONTRACTOR SHALL ACQUIRE LABEL CERTIFICATES FOR SITE-BUIT GLAZING SYSTEMS AS REQUIRED BY THE CODE OFFICAL. CONTRACTOR SHALL HAVE THE OPTION OF SELECTING EITHER THE "CERTIFIED PRODUCT" OR "CERTIFIED PROJECT PATH" PER NFRC 100 G1 1/4" CLEAR GLAZING -TEMPERED GLAZING SCHEDULE METAL WALL FRAMING STUD @ 16" O.C., ATTACH TO DECK STORE FRONT RIBBON ASSEMBLY SYSTEM, STANDARD ALUMINUM FINISH, RE: SPECIFICATIONS SEALANT BOTH SIDES TYP.SHIM 5/8" GYP BOARD, TYP METAL CORNER, EACH SIDE SB3 b SB4 b 2 1/2" METAL FRAMING STUD @ 16" O.C., ATTACH TO DECK STORE FRONT RIBBON ASSEMBLY SYSTEM, STANDARD ALUMINUM FINISH, RE: SPECIFICATIONS SEALANT BOTH SIDES TYP. SHIM 5/8" GYP BOARD, TYP METAL CORNER, EACH SIDE STORE FRONT RIBBON ASSEMBLY SYSTEM, STANDARD ALUMINUM FINISH, RE: SPECIFICATIONS SEALANT BOTH SIDES TYP. SHIM 5/8" GYP BOARD, TYP SB3 b EXISTING MASONRY WALL TO REMAINBACKSPLASH, RE: FINISH SCHED. EPOXY RESIN SILL TO MATCH NEW COUNTERTOP FINISH. INSTALL ON BOTH SIDES OF STOREFRONT. RE: FINISH SCHED SS-01 1 EXISTING WALL AND FINISH TO REAMAIN COVER CUT OPENING WITH WITH NEW SILL, RE: FINISH SCHED SS-01 EXISTING GLAZING TO REMAIN CONTINUOUS SEALANTAT THE PERIMETER OF THE NEW SILL 1 C EXISTING WALL AND FINISH TO REMAIN NEW INFILL FRAMING AND GYP BOARD TO COVER CUT OPENING EXISTING GLAZING TO REMAIN 1 FRAME OVER (LEFT OR RIGHT) TO THE NEAREST MULLION. COVER ALL NEW FRAMING WITH 5/8" GYPSUM BOARD AND FINISH EXISTING WALL AND FINISH TO REAMAIN EXISTING GLAZING TO REMAIN NEW WALL AS SCHEDULED, RE: DIMENSION PLANS B1 A601 C1 A601 A1 A601 3 '-5 1 /2 " 3 '-6 1 /2 " 4'-0" SF1 ALUM STOREFRONT G1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A601 DOOR & WINDOW TYPES AND SCHEDULE 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set GENERAL NOTES - DOORS 1 ALL HOLLOW METAL FRAMES AND DOORS ARE TO BE PAINTED TO MATCH ADJACENT WALL FINISH, UNLESS NOTED OTHERWISE 2 ALL INTERIOR HOLLOW METAL FRAME WIDTHS ARE TO MATCH WALL WIDTHS; COORDINATE WITH VERTICAL ASSEMBLY TYPES 3 WOOD GRAIN DIRECTION TO BE VERTICAL, UNLESS NOTED OTHERWISE 4 FINISH OF METAL FRAMES ADJACENT TO METAL PANEL TO MATCH METAL PANEL COLOR, UNLESS NOTED OTHERWISE 5 COLOR TRANSITIONS TO OCCUR AT INSIDE OF FRAME STOP 6 DOORS SERVING SPACES WITH AN OCCUPANT LOAD OF 50 OR MORE SHALL NOT BE PROVIDED WITH A LATCH OR LOCK OTHER THAN PANIC HARDWARE. SEE DOOR HARDWARE SPECIFICATIONS 7 PROVIDE TEMPERED GLASS AT ALL CODE REQUIRED LOCATIONS 8 REFER TO SPECIFICATIONS FOR ALL HARDWARE SETS ALL DOOR HANDLES & HARDWARE USED ON THE PROJECT MUST NOT REQUIRE PINCHING, TIGHT GRASPING, OR TWISTING OF THE WRIST IN ORDER TO OPERATE, IN ACCORDANCE WITH 2018 IBC 1010.1.9.1 DOOR SCHEDULE - ALL wt ROOMS DOOR DIMENSIONS DOOR FRAME FIRE RATING MS_Card Access HwSet# DOOR NUMBER COMMENTSTO RM # WIDTH HEIGHT THK TYPE MATERIAL FINISH TYPE MATERIAL FINISH LEVEL 00 0-H VESTIBULE 0-H 3' - 0" 6' - 10" 1 3/4" D1 ALUMINUM DARK BRONZE F3 ALUMINUM DARK BRONZE No AL01 0-H 50 CLASSROOM 50 3' - 0" 7' - 0" 1 3/4" D2 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 05 50 51.1 PHOTO STUDIO 51 3' - 0" 7' - 0" 1 3/4" D3 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 06 51.1 51.2 PHOTO STUDIO 51 3' - 0" 7' - 0" 1 3/4" D4 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 11 51.2 51A STORAGE 51A 3' - 0" 7' - 0" 1 3/4" D4 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 03 51A 51B CHANGING 51B 3' - 0" 7' - 0" 1 3/4" D4 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 10 51B 52.1 HALLWAY O-C 5' - 0" 7' - 0" 1 3/4" D6 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 Yes 17 52.1 52.2 PHYSICS LAB 52 3' - 0" 7' - 0" 1 3/4" D7 HM DOOR PAINTED; PNT-03 F1 HM PAINTED; PNT-03 No 12 52.2 52A OPTICS LAB 52A 3' - 0" 7' - 0" 1 3/4" D4 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 08 52A 52B ACOUSTICS STUDIO 52B 3' - 0" 7' - 0" 1 3/4" D3 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 02 52B 52C STORAGE 52C 3' - 0" 7' - 0" 1 3/4" D2 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 03 52C 55 OFFICE 55 3' - 0" 7' - 0" 1 3/4" D2 WOOD-SOLID CORE STAINED F2 HM PAINTED; PNT-03 No 08 55 57 OFFICE 57 3' - 0" 7' - 0" 1 3/4" D2 WOOD-SOLID CORE STAINED F2 HM PAINTED; PNT-03 No 08 57 59.1 COMPUTER LAB 59 3' - 0" 7' - 0" 1 3/4" D3 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 04 59.1 59.2 COMPUTER LAB 59 3' - 0" 7' - 0" 1 3/4" D3 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 Yes 07 59.2 59A.1 EQUIP / CHECK OUT 59A 3' - 0" 7' - 0" 1 3/4" D3 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 08 59A.1 59A.2 EQUIP / CHECK OUT 59A 3' - 0" 7' - 0" 1 3/4" D3 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 08 59A.2 59C VESTIBULE 59C 3' - 0" 7' - 0" 1 3/4" D3 WOOD-SOLID CORE STAINED EXIST EXISTING HM PAINTED; PNT-03 No 13 59C 59D DARK ROOM 59D 3' - 0" 7' - 0" 1 3/4" D4 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 01 59D 59E FILM 59E 3' - 0" 7' - 0" 1 3/4" D4 WOOD-SOLID CORE STAINED F1 HM PAINTED; PNT-03 No 01 59E 68 CUST RM 68 3' - 0" 7' - 0" 1 3/4" D7 HM DOOR PAINTED; PNT-03 F1 HM PAINTED; PNT-03 No 15 68 69 MECHANICAL ROOM 69 5' - 0" 7' - 0" 1 3/4" D5 HM DOOR PAINTED; PNT-03 F1 HM PAINTED; PNT-03 90 MIN No 16 69 LEVEL 02 272 BIO-CHEMISTRY LAB 272 3' - 0" 7' - 0" 1 3/4" D2 WOOD-SOLID CORE STAINED F3 HM PAINTED; PNT-03 No 09 272 276 CLASSROOM 276 3' - 0" 7' - 0" 1 3/4" D2 WOOD-SOLID CORE STAINED F2 HM PAINTED; PNT-03 No 14 276 3" = 1'-0"E2 HM JAMB STUD DETAIL 3" = 1'-0"E1 HM HEAD STUD DETAIL 1/4" = 1'-0"D4 FRAME TYPES 1/4" = 1'-0"C2 DOOR TYPES 3" = 1'-0"B5 INTERIOR STOREFRONT HEAD TYP 3" = 1'-0"A4 INTERIOR STOREFRONT JAMB 3" = 1'-0"A5 INTERIOR STOREFRON @ FLOOR TYP GLAZING GENERAL NOTES 1 CONTRACTOR TO CONFIRM AND VERIFY QUANTITIES OF ALL GLAZING TYPES 2 ALL GLAZING DIMENSIONS TO BE FIELD VERIFIED PRIOR TO BIDDING, ORDERING, AND INSTALLING 3 ROUGH OPENING REQUIREMENTS SHALL BE COORDINATED WITH WINDOW MANUFACTURER, TYP 4 ALL CURTAINWALL SYSTEMS REQUIRE DELEGATED DESIGN SUBMITTAL 5 SEE DOOR SCHEDULE FOR SCHEDULED GLAZING WITHIN DOORS 6 SEE FLOOR PLAN AND ELEVATIONS FOR WALL TYPE AND MATERIAL CONDITION IN REFERING TO WINDOW AND STOREFRONT DETAILS 7 SAFETY GLAZING SHALL BE INSTALLED IN HAZARDOUS LOCATIONS WITH IBC 2406.4, THIS INCLUDES GLAZING IN WINDOW, STOREFRONT, AND DOOR TYPES. *Refer to hardware specifications for doors with electrical hardware. 3" = 1'-0"B1 BIO-CHEM. LAB WINDOW HEAD DETAIL - INT. 3" = 1'-0"C1 BIO-CHEM. LAB WINDOW JAMB DETAIL - INT. 3" = 1'-0"A1 BIO-CHEM. LAB WINDOW SILL DETAIL - INT. 1 1/2" = 1'-0"A2 BIO- CHEMISTRY LAB SILL DETAIL - EXTERIOR 1 1/2" = 1'-0"B2 BIO-CHEM. LAB JAMB DETAIL - EXTERIOR 1 1 1/2" = 1'-0"B3 BIO-CHEM. LAB JAMB DETAIL - EXTERIOR 2 1/4" = 1'-0"C6 WINDOW TYPES FLOOR FINISH LEGEND CARPET TILE Room name 101 F B W WALL FINISH BASE FINISH FLOOR FINISH ROOM NUMBER FINISH KEY FINISH CODE; REFER TO ELEVATIONS FOR ENTIRE SCOPE. REFER TO FINISH SCHEDULE FOR BASIS OF DESIGN. CPT-02 CPT-01 SHEET GOOD FLOORING EPOXY FLOORING RF-01 SF-01 SEALED CONCRETECNC-01 NOTE: INDICATES MAIN FIELD FINISH; ASSUME THIS FINISH IN ENTIRE AREA UNLESS AN ACCENT IS CALLED OUT IN PLANS OR ELEVATION CARPET TILE *MULTIPLE FINISHES; SEE ELEVATION TYP. ROOM FINISH TAG ACCENT TAG XX - X X EX T E N T O F F I N I S H SC O P E ENTRY MAT TILEEM-01 TL-01 PORCELAIN TILE RF-02 LUXURY VINYL PLANK * SEE ENLARGED FINISH PLANS + INTERIOR ELEVATIONS+ FINISH SCHEDULE SHEET FOR MORE INFORMATION * ARROWS REPRESENT EXTENT OF SCOPE EXISTINGEXISTCPT-03 CARPET TILE PHYSICS LAB 52 SF-01 WB-01 PNT-01 CLASSROOM 50 CPT-01 WB-01 PNT-01 PHOTO STUDIO 51 RF-01 RB-01 PNT-01 COMPUTER LAB 59 CPT-01 WB-01 PNT-01 DARK ROOM 59D RF-01 WB-01 PNT-01 EQUIP / CHECK OUT 59A CPT-02 WB-01 PNT-01 HALLWAY O-C CPT-01 WB-01 PNT-01 MEN'S RM 66 EXIST EXIST EXIST WOMEN'S RM 64 EXIST EXIST EXIST STORAGE 51A RF-01 WB-01 PT-01 VESTIBULE 59C RF-01 WB-01 PNT-01 FILM 59E RF-01 WB-01 PNT-01 VESTIBULE 0-H EM-01 WB-01 PT-01 CHANGING 51B RF-01 WB-01 PT-01 STORAGE 52C SF-01 WB-01 PNT-01 OPTICS LAB 52A CPT-01 WB-01 PNT-01 ACOUSTICS STUDIO 52B CPT-01 WB-01 WC-01 CUST RM 68 EXIST WB-01 PNT-01 VESTIBULE O-A EM-01 WB-01 PNT-01 OFFICE 55 CPT-02 WB-01 PNT-01 OFFICE 57 CPT-02 WB-01 PNT-01 STORAGE 59B CPT-02 WB-01 PNT-01 RF-02 19'-10" WB-02 WB-02 WB-02 WB - 0 2 WB - 0 2 WB-02 WB-02 WB - 0 2 WB-02 WB - 0 2 PNT-04 WB-03 LEVEL 5 FINISH DIRECTION OF FLOORING TS-02 TS-04 TS-05 TS-05 TS-05TS-05 TS-04 TS-04 EXIST SF-01 09.30 09.30 DIRECTION OF FLOORING DI R E C T I O N O F F L O O R I N G DI R E C T I O N O F F L O O R I N G 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A700 LEVEL 00 FINISH PLANS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set GENERAL NOTES - FINISH 1 RE: FLOOR PLANS FOR INTERIOR ELEVATIONS 2 ALL MATERIALS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS 3 FLOORING MATERIAL TRANSITIONS TO OCCUR AT CENTERLINE OF DOOR THRESHOLDS, UNLESS NOTED OTHERWISE 4 PREPARE FLOORS/WALLS TO RECEIVE FINISH MATERIAL. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR SURFACE PREPARATION. NOTIFY ARCHITECT IF CONDITIONS ARE INADEQUATE FOR REQUIRED INSTALLATION 5 RE: ROOM FINISH LEGEND ON SHEET SERIES A700 FOR MORE INFORMATION 6 RE: DIMENSION PLAN SHEET SERIES A120 FOR WALL TYPE LOCATIONS; RE: SHEET SERIES A500 FOR WALL TYPE AND ASSEMBLY DESCRIPTIONS 7 CONTRACTOR TO PROVIDE SOLID BLOCKING AT ALL CASEWORK, FIXED FURNISHINGS, AND EQUIPMENT. COORDINATE WITH ELEVATIONS, SECTIONS, FURNITURE, FIXTURE SHEETS, AND SPECIFICATIONS 8 RE: SHEET SERIES A500 FOR TYPICAL DETAILS 9 TILE INSTALLER TO FOLLOW TCNA & ANSI GUIDELINES 10 ALL FLOORING MATERIALS ARE TO RUN WALL TO WALL AND BENEATH CASEWORK 11 VERIFY LOCATION OF POINT OR ORIGIN OF TILE AND CONTROL JOINTS ON SHOP DRAWINGS AND WITH ARCHITECT ON-SITE PRIOR TO INSTALLATION 12 ALL GROUT TO BE SEALED 13 GENERAL CONTRACTOR TO COORDINATE POWER/DATA PLACEMENT WITH FURNITURE PROVIDER 14 LEVEL 5 FINISH REQUIRED FOR ALL WALL GRAPHIC AND WALLCOVERING LOCATIONS. SEE FINISH PLANS AND ELEVATIONS FOR LOCATIONS 15 ALL METAL STUD WALLS TO DECK ABOVE, UNLESS NOTED OTHERWISE; SEE SHEET SERIES A500 FOR WALL TYPES 16 PROVIDE DEFLECTION TRACKS AT ALL STUD WALLS RE: DETAILS ON SHEET SERIES A500 17 ALL EXPOSED METAL TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS 3/16" = 1'-0"A1 LEVEL 00 FINISH PLAN WOMEN'S RM 132 TL-01 TS-01 * MEN'S RM 134 TL-01 TS-01 * UNISEX RM 136 TL-01 TS-01 * PHYSICAL GEOLOGY ROOM 158 EXIST WB-01 PNT-01 TS-02 TS-02 TS-02 FLOOR FINISH LEGEND CARPET TILE Room name 101 F B W WALL FINISH BASE FINISH FLOOR FINISH ROOM NUMBER FINISH KEY FINISH CODE; REFER TO ELEVATIONS FOR ENTIRE SCOPE. REFER TO FINISH SCHEDULE FOR BASIS OF DESIGN. CPT-02 CPT-01 SHEET GOOD FLOORING EPOXY FLOORING RF-01 SF-01 SEALED CONCRETECNC-01 NOTE: INDICATES MAIN FIELD FINISH; ASSUME THIS FINISH IN ENTIRE AREA UNLESS AN ACCENT IS CALLED OUT IN PLANS OR ELEVATION CARPET TILE *MULTIPLE FINISHES; SEE ELEVATION TYP. ROOM FINISH TAG ACCENT TAG XX - X X EX T E N T O F F I N I S H SC O P E ENTRY MAT TILEEM-01 TL-01 PORCELAIN TILE RF-02 LUXURY VINYL PLANK * SEE ENLARGED FINISH PLANS + INTERIOR ELEVATIONS+ FINISH SCHEDULE SHEET FOR MORE INFORMATION * ARROWS REPRESENT EXTENT OF SCOPE EXISTINGEXISTCPT-03 CARPET TILE 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A701 LEVEL 01 FINISH PLANS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 3/16" = 1'-0"A1 LEVEL 01 FINISH PLAN GENERAL NOTES - FINISH 1 RE: FLOOR PLANS FOR INTERIOR ELEVATIONS 2 ALL MATERIALS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS 3 FLOORING MATERIAL TRANSITIONS TO OCCUR AT CENTERLINE OF DOOR THRESHOLDS, UNLESS NOTED OTHERWISE 4 PREPARE FLOORS/WALLS TO RECEIVE FINISH MATERIAL. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR SURFACE PREPARATION. NOTIFY ARCHITECT IF CONDITIONS ARE INADEQUATE FOR REQUIRED INSTALLATION 5 RE: ROOM FINISH LEGEND ON SHEET SERIES A700 FOR MORE INFORMATION 6 RE: DIMENSION PLAN SHEET SERIES A120 FOR WALL TYPE LOCATIONS; RE: SHEET SERIES A500 FOR WALL TYPE AND ASSEMBLY DESCRIPTIONS 7 CONTRACTOR TO PROVIDE SOLID BLOCKING AT ALL CASEWORK, FIXED FURNISHINGS, AND EQUIPMENT. COORDINATE WITH ELEVATIONS, SECTIONS, FURNITURE, FIXTURE SHEETS, AND SPECIFICATIONS 8 RE: SHEET SERIES A500 FOR TYPICAL DETAILS 9 TILE INSTALLER TO FOLLOW TCNA & ANSI GUIDELINES 10 ALL FLOORING MATERIALS ARE TO RUN WALL TO WALL AND BENEATH CASEWORK 11 VERIFY LOCATION OF POINT OR ORIGIN OF TILE AND CONTROL JOINTS ON SHOP DRAWINGS AND WITH ARCHITECT ON-SITE PRIOR TO INSTALLATION 12 ALL GROUT TO BE SEALED 13 GENERAL CONTRACTOR TO COORDINATE POWER/DATA PLACEMENT WITH FURNITURE PROVIDER 14 LEVEL 5 FINISH REQUIRED FOR ALL WALL GRAPHIC AND WALLCOVERING LOCATIONS. SEE FINISH PLANS AND ELEVATIONS FOR LOCATIONS 15 ALL METAL STUD WALLS TO DECK ABOVE, UNLESS NOTED OTHERWISE; SEE SHEET SERIES A500 FOR WALL TYPES 16 PROVIDE DEFLECTION TRACKS AT ALL STUD WALLS RE: DETAILS ON SHEET SERIES A500 17 ALL EXPOSED METAL TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS MEN'S ROOM 226 TL-01 TS-01 * WOMEN'S ROOM 220 TL-01 TS-01 * BIO-CHEMISTRY LAB 272 SF-01 RB-01 PNT-01 TS-04 TS-02 TS-02 CPT-03 09.30 FLOOR FINISH LEGEND CARPET TILE Room name 101 F B W WALL FINISH BASE FINISH FLOOR FINISH ROOM NUMBER FINISH KEY FINISH CODE; REFER TO ELEVATIONS FOR ENTIRE SCOPE. REFER TO FINISH SCHEDULE FOR BASIS OF DESIGN. CPT-02 CPT-01 SHEET GOOD FLOORING EPOXY FLOORING RF-01 SF-01 SEALED CONCRETECNC-01 NOTE: INDICATES MAIN FIELD FINISH; ASSUME THIS FINISH IN ENTIRE AREA UNLESS AN ACCENT IS CALLED OUT IN PLANS OR ELEVATION CARPET TILE *MULTIPLE FINISHES; SEE ELEVATION TYP. ROOM FINISH TAG ACCENT TAG XX - X X EX T E N T O F F I N I S H SC O P E ENTRY MAT TILEEM-01 TL-01 PORCELAIN TILE RF-02 LUXURY VINYL PLANK * SEE ENLARGED FINISH PLANS + INTERIOR ELEVATIONS+ FINISH SCHEDULE SHEET FOR MORE INFORMATION * ARROWS REPRESENT EXTENT OF SCOPE EXISTINGEXISTCPT-03 CARPET TILE 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A702 LEVEL 02 FINISH PLANS 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 3/16" = 1'-0"A1 LEVEL 02 FINISH PLAN GENERAL NOTES - FINISH 1 RE: FLOOR PLANS FOR INTERIOR ELEVATIONS 2 ALL MATERIALS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS 3 FLOORING MATERIAL TRANSITIONS TO OCCUR AT CENTERLINE OF DOOR THRESHOLDS, UNLESS NOTED OTHERWISE 4 PREPARE FLOORS/WALLS TO RECEIVE FINISH MATERIAL. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR SURFACE PREPARATION. NOTIFY ARCHITECT IF CONDITIONS ARE INADEQUATE FOR REQUIRED INSTALLATION 5 RE: ROOM FINISH LEGEND ON SHEET SERIES A700 FOR MORE INFORMATION 6 RE: DIMENSION PLAN SHEET SERIES A120 FOR WALL TYPE LOCATIONS; RE: SHEET SERIES A500 FOR WALL TYPE AND ASSEMBLY DESCRIPTIONS 7 CONTRACTOR TO PROVIDE SOLID BLOCKING AT ALL CASEWORK, FIXED FURNISHINGS, AND EQUIPMENT. COORDINATE WITH ELEVATIONS, SECTIONS, FURNITURE, FIXTURE SHEETS, AND SPECIFICATIONS 8 RE: SHEET SERIES A500 FOR TYPICAL DETAILS 9 TILE INSTALLER TO FOLLOW TCNA & ANSI GUIDELINES 10 ALL FLOORING MATERIALS ARE TO RUN WALL TO WALL AND BENEATH CASEWORK 11 VERIFY LOCATION OF POINT OR ORIGIN OF TILE AND CONTROL JOINTS ON SHOP DRAWINGS AND WITH ARCHITECT ON-SITE PRIOR TO INSTALLATION 12 ALL GROUT TO BE SEALED 13 GENERAL CONTRACTOR TO COORDINATE POWER/DATA PLACEMENT WITH FURNITURE PROVIDER 14 LEVEL 5 FINISH REQUIRED FOR ALL WALL GRAPHIC AND WALLCOVERING LOCATIONS. SEE FINISH PLANS AND ELEVATIONS FOR LOCATIONS 15 ALL METAL STUD WALLS TO DECK ABOVE, UNLESS NOTED OTHERWISE; SEE SHEET SERIES A500 FOR WALL TYPES 16 PROVIDE DEFLECTION TRACKS AT ALL STUD WALLS RE: DETAILS ON SHEET SERIES A500 17 ALL EXPOSED METAL TO BE INSTALLED PER SPECIFIC MANUFACTURER'S INSTALLATION RECOMMENDATIONS 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A710 FINISH SCHEDULES, ACCESSORY SCHEDULES 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set SCEDULED MATERIALS AND FINISHES SHALL BE USED FOR BASIS OF DESIGN U.N.O. FINISH SCHEDULE CODE PRODUCT TYPE MANUFACTERER STYLE COLOR DIVISION FINISH NOTES/ REMARKS SPECIFICATION DIVISION 06 - WOODS, PLASTICS & COMPOSITES FRP-01 FIBER-GLASS REINFORCED PANEL MARLITE SMOOTH WHITE S100G DIVISION 06 - WOODS, PLASTICS & COMPOSITES AT ALL JANITOR SINKS, COORDINATING FACTORY TRIM PROVIDED AT ALL OUTSIDE EDGES, INSTALLATION PER MANUFACTURERS INSTRUCTIONS PL-01 PLASTIC LAMINATE WILSONART GRAPHITE 10657 DIVISION 06 - WOODS, PLASTICS & COMPOSITES BASE CABINETS MATTE FINISH 60 PL-02 PLASTIC LAMINATE WILSONART STANDARD LAMINATE CRISP LINEN 4942 DIVISION 06 - WOODS, PLASTICS & COMPOSITES COUNTERTOPS FINE VELVET FINISH 38 WV-01 WOOD VENEER RED OAK CHERRY MOHOGANY DIVISION 06 - WOODS, PLASTICS & COMPOSITES FINISH TO MATCH EXISTING CABINETS. CONTRACTOR TO FIELD VERIFY WITH OWNER GRAIN TO RUN VERTICAL, ALKYD WIPING STAIN DIVISION 07 - THERMAL & MOISTURE PROTECTION SAT-01 SPRAY-ON THERMAL & ACOUSTICAL INSULATION INTERNATIONAL CELLULOSE CORPORATION K13 DIVISION 07 - THERMAL & MOISTURE PROTECTION DIVISION 09 - BASE & TRANSITIONS TS-01 METAL COVE BASE SCHLUTER DILEX-AHK SATIN ANNODIZED ALUMINUM DIVISION 09 - BASE & TRANSITIONS HEIGHT TO MATCH MATERIAL THICKNESS. INTSTALL PER MANUFACTURERS INSTRUCTIONS. TS-02 METAL FLOOR TRANSITION STRIP SCHLUTER SCHIENE SATIN ANNODIZED ALUMINUM DIVISION 09 - BASE & TRANSITIONS HEIGHT TO MATCH MATERIAL THICKNESS. INTSTALL PER MANUFACTURERS INSTRUCTIONS. TS-03 METAL EDGE TRIM SCHLUTER JOLLY SATIN ANNODIZED ALUMINUM DIVISION 09 - BASE & TRANSITIONS HEIGHT TO MATCH MATERIAL THICKNESS. INTSTALL PER MANUFACTURERS INSTRUCTIONS. TS-04 RUBBER FLOOR TRANSITION TARKETT EG-XX-H TO BE SELECTED FROM MANUFACTURERS FULL LINE OF COLORS DIVISION 09 - BASE & TRANSITIONS 1/4" MATERIAL TO FLOOR 100% VULCANIZED RUBBER TRANSITION STRIP TS-05 RUBBER FLOOR TRANSITION TARKETT SLT-XX-A TO BE SELECTED FROM MANUFACTURERS FULL LINE OF COLORS DIVISION 09 - BASE & TRANSITIONS 1/4" MATERIAL TO 1/8" MATERIAL 100% VULCANIZED RUBBER TRANSITION STRIP WB-01 RUBBER WALL BASE TARKETT 4" TRADITIONAL WALL BASE, WITH TOE 01 SNOW WHITE DIVISION 09 - BASE & TRANSITIONS INSTALLATION PER MANUFACTURERS INSTURCTIONS, RE: FINISH PLANS AND ELEVATIONS FOR LOCATIONS WB-02 RUBBER WALL BASE TARKETT 4" TRADITIONAL WALL BASE, TOELESS COOL METAL VL4 DIVISION 09 - BASE & TRANSITIONS BASE AT CASEWORK INSTALLATION PER MANUFACTURERS INSTRUCTIONS, RE: FINISH PLANS AND ELEVATIONS FOR LOCATIONS. WB-03 RUBBER WALL BASE TARKETT 4" TRADITIONAL WALL BASE, WITH TOE 29 MOON ROCK DIVISION 09 - BASE & TRANSITIONS INSTALLATION PER MANUFACTURERS INSTRUCTIONS, RE: FINISH PLANS AND ELEVATIONS FOR LOCATIONS. DIVISION 09 - CEILINGS ACP-01 ACOUSTICAL CEILING PANEL USG 2110 RADAR WHITE DIVISION 09 - CEILINGS 24" X 24" USG 15/16" DOWN SUSPENSION SYSTEM SC-01 SPECIALTY CEILING SOUNDASSURED ACOUSTIC FOAM PANELS CHARCOAL DIVISION 09 - CEILINGS 12"x12"x4" PANEL. ATTACHED TO GYP CEILING. RE: MANUFACTURER'S RECOMMENDATIONS DIVISION 09 - FLOORS CPT-01 CARPET TILE INTERFACE SOURCE MATERIAL - STREAMING GRAPHITE 106308 DIVISION 09 - FLOORS 2. GENERAL CAPRET FLOORING 25CM x 1M, ASHLAR INSTALLATION, DIRECT GLUE, INSTALATION PER MANUFACTURERS INSTALLATION INSTRUCTIONS, RE: FINISH PLANS FOR LOCATIONS AND INSTALLATION DIRECTION. CPT-02 CARPET TILE INTERFACE OPEN AIR 404 NICKEL 106750 DIVISION 09 - FLOORS 2. GENERAL CAPRET FLOORING 50CM x 50CM, MONOLITHIC, DIRECT GLUE, INSTALLATION PER MANUFACTURERS INSTALLATION INSTRUCTIONS, RE: FINISH PLANS FOR LOCATIONS AND INSTALLATION DIRECTION CPT-03 CARPET TILE INTERFACE ENTROPY PRALINE 9606 DIVISION 09 - FLOORS 2. GENERAL CAPRET FLOORING 50CM x 50CM, NON DIRECTIONAL, DIRECT GLUE, INTALLATION PER MANUFACTURERS INSTALLATION INSTRUCTIONSM RE: FINISH PLANS FOR LOCATIONS AND INSTALLATION DIRECTION EM-01 CARPET TILE - ENTRY MAT INTERFACE STEP REPEAT IRON 104940 DIVISION 09 - FLOORS 2. GENERAL CAPRET FLOORING - RF-01 SHEET VINYL PATCRAFT MEANING SHEET 1584V EXPERIENCE 00590 DIVISION 09 - FLOORS 79"x65' SHEET SIZE, INSTALLATION PER MANUFACTURERS INSTRUCTIONS RF-02 LUXURY VINYL TILE INTERFACE #A004 LEVEL SET TEXTURED WOODGRAINS A00417 SILVER DUNE DIVISION 09 - FLOORS 25CMx1M, 22MIL, ASHLAR INSTALLATION, RE: FINISH PLANS FOR LOCATIONS AND FLOORING DIRECTIONS. DIRECT GLUE, INSTALLATION PER MANUFACTURERS INSTRUCTIONS SF-01 EPOXY FLOORING RUST-OLEUM 9100 SERIES EPOXY SILVER GRAY DIVISION 09 - FLOORS TWO COATS MINIMUM DIVISION 09 - PAINT & WALLCOVERING PNT-01 FIELD WALL PAINT SHERWIN WILLIAMS CASHMERE SHELL WHITE BYUI CUSTOM MATCH DIVISION 09 - PAINT & WALLCOVERING MEDIUM LUSTER PNT-02a FIELD CEILIING PAINT SHERWIN WILLIAMS BYUI STANDARD FOR CEILING PAINT SHELL WHITE SW8917 DIVISION 09 - PAINT & WALLCOVERING FLAT FINISH PNT-02b EXPOSED DECK PAINT SHERWIN WILLIAMS BYUI STANDARD FOR CEILING PAINT IRON ORE SW7069 DIVISION 09 - PAINT & WALLCOVERING FLAT FINISH PNT-03a TRIM PAINT (HOLLOW METAL FRAMES)PITTSBURG PAINTS BYUI STANDARD FOR DOOR + DOOR FRAME PAINT BLACK 164 MIXED WITH WHITE 36 DIVISION 09 - PAINT & WALLCOVERING CONFIRM COLOR MATCHES EXISTING BASEMENT FRAMES ACRYLIC, DTM, MEDIUM LUSTRE PNT-03b TRIM PAINT (HOLLOW METAL FRAMES)BENJAMIN MOORE C235-4B BYUI STANDARD FOR DOOR + DOOR FRAME PAINT RX 4x 29.2500, BB 7x 1.2500, WH 0x 1.5000 DIVISION 09 - PAINT & WALLCOVERING CONFIRM COLOR MATCHES EXISTING LEVEL 2 FRAMES ACRYLIC, DTM, MEDIUM LUSTRE PNT-04 ACCENT PAINT SHERWIN WILLIAMS GAUNTLET GRAY SW7019 DIVISION 09 - PAINT & WALLCOVERING FLAT FINISH. DRY WALL TO BE PREPARED TO LEVEL 5 FINISH BEFORE PAINTING WC-01 WALL COVERING SOUNDASSURED ACOUSTIC FOAM PANELS CHARCOAL DIVISION 09 - PAINT & WALLCOVERING 12"x12"x4" PANEL DIVISION 09 - TILE TL-01 FLOOR TILE DALTILE SOCIETY PARK LANE GRAY SO47 DIVISION 09 - TILE POLISHED, 12"x24", THICKNESS: 3/8", INSTALL: ONE THIRD OFFSET, GROUT: TBD, RE: FINISH PLANS FOR LOCATIONS TL-02 WALL TILE DALTILE COLOR WHEEL - LINEAR MATTE ARCTIC WHITE 0790 DIVISION 09 - TILE 4"x12", HORIZONTAL, STACKED BOND INSTALLATION, THICKNESS 3/8", GROUT: TBD, RE: ELEVATIONS + FINISH PLANS FOR LOCATIONS. FULL TILE TOP ROW TL-03 WALL TILE DALTILE COLOR WHEEL - LINEAR NAVY K189 DIVISION 09 - TILE 4"x12", HORIZONTAL, STACKED BOND INSTALLATION, THICKNESS 3/8", GROUT: TBD, RE: ELEVATIONS + FINISH PLANS FOR LOCATIONS. FULL TILE TOP ROW DIVISION 12 - FURNISHINGS RS-01 ROLLER SHADES DRAPER SINGLE SHADE 1% OPENESS, MANUAL SCREEN FABRIC: MERMET E SCREEN, PEARL GRAY DIVISION 12 - FURNISHINGS 1% OPEN - SS-01 EPOXY RESIN COUNTERTOP AMERICAN EPOXY SCIENTIFIC BLACK DIVISION 12 - FURNISHINGS PRODUCT TO MATCH EXISTING COUNTERTOP 1" THICK, 3/16" RADIUS, 96" LENGTH HARDWARE SCHEDULE PRODUCT TYPE MODEL FINISH SPECIFICATIONS CABINET PULL - BASEMENT LEVEL AMEROCK EDGE PULL SATIN NICKEL 3.75" WALL HOOKS RICHELIEU DOUBLE ROBE HOOK, NH1253021195 BRUSHED NICKEL RE: ELEVATIONS FOR QTY. CABINET LOCKS OLYMPUS LOCKER PER CAMPUS STANDARD CABINET PULL - LEVEL 1 AND 2 MATCH EXISTING HARDWARE SCHEDULED MATERIALS AND FINISHES SHALL BE USED FOR BASIS OF DESIGN U.N.O. ACCESSORY SCHEDULE CODE PRODUCT TYPE MANUFACTURER MAKE/MODEL FINISH COMMENTS 10.01 FRAMELESS MIRROR N/A 24" W x 42" H PENCIL EDGE GRIND ADHERED DIRECTLY TO FINISH WALL 10.02 36" GRAB BAR BOB B-2111 SATIN FINISH; STAINLESS STEEL CONTRACTOR PROVIDED / CONTRACTOR INSTALLED, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE G011 FOR MOUNTING HEIGHTS. 10.03 WALL MOUNTED SOAP DISPENSER OWNER PROVIDED/ OWNER INSTALLED INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE G011 FOR MOUNTING HEIGHTS 10.05 TOILET PAPER HOLDER OWNER PROVIDED/ OWNER INSTALLED INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE G011 FOR MOUNTING HEIGHTS 10.06 PAPER TOWEL DISPENSER OWNER PROVIDED/ OWNER INSTALLED INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE G011 FOR MOUNTING HEIGHTS 10.10 42" GRAB BAR BOB B-2111 SATIN FINISH; STAINLESS STEEL CONTRACTOR PROVIDED / CONTRACTOR INSTALLED, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE G011 FOR MOUNTING HEIGHTS. 10.16 18" GRAB BAR BOB B-2111 SATIN FINISH; STAINLESS STEEL CONTRACTOR PROVIDED / CONTRACTOR INSTALLED, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE G011 FOR MOUNTING HEIGHTS. 10.20 SANITARY NAPKIN DISPOSAL OWNER PROVIDED/ OWNER INSTALLED INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE G01 1 FOR MOUNTING HEIGHTS 10.27 TOILET SEAT COVER DISPENSER BOBRICK B-4221 SATIN FINISH; STAINLESS STEEL INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE G011 FOR MOUNTING HEIGHTS 10.28 FRAMELESS MIRROR N/A 18" W x24" H PENCIL EDGE GRIND ADHERED DIRECTLY TO FINISH WALL A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 STORAGE 18 CUST OFFICE 16 CUSTODIAL LAUNDRY RM 14 MEN'S RM 66 WOMEN'S RM 64 MECHANICAL ROOM 69 MECHANICAL RM 10 VESTIBULE O-A MECH RM 12 HALLWAY O-C STORAGE 63 STAIRWELL O-B PIPE CHASE O-Q ELEVATOR O-D MECH RM 67 CUST RM 68 STAIRWELL 0-F STORAGE 20 ELEVATOR 0-K ELEC VAULT 80 HALLWAY 0-N COMPACT FILL COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E T U N N E L CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE CLASSROOM 50 DARK ROOM 59D COMPUTER LAB 59 PHOTO STUDIO 51 VESTIBULE 59C OFFICE 57 EQUIP / CHECK OUT 59A STORAGE 59B OFFICE 55 FILM 59E ACOUSTICS STUDIO 52B STORAGE 51A CHANGING 51B VESTIBULE 0-H OPTICS LAB 52A PHYSICS LAB 52 STORAGE 52C (PHOTO EQUIPMENT) (PHOTO EQUIPMENT) POSITRON LAB HIGH ALTITUDE RESEARCH TEAM VACUUM AND THIN FILMS LAB needs straps A910 A1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A900 LEVEL 00 FURNITURE PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 00 FURNITURE PLAN NOTE: FURNITURE IS OWNER FURNISHED AND OWNER INSTALLED, UNLESS NOTED OTHERWISE. THE FOLLOWING LAYOUT IS TO HELP COORDINATE INFRASTURCTURE AND SUPPORT FOR THE FURNITURE. UPDATES WILL BE PROVIDED BY BYUI AT A LATER DATE. A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 PLANRTARIUM RM 107 LIGHT TRAP I-Y HAZ. STORAGE 167 HAZ. STORAGE 166 ROCK LABORATORY 164 MEN'S T.R. 162 WOMEN'S T.R. 160 PIPE CHASE I-Q HALLWAY 1-T LAB PREP ROOM 161 ELEVATOR 1-M CUST. 147 STAIRWELL 1-P PHYSICAL GEOLOGY ROOM 158 PHYSICAL SCIENCE DISPLAY ROOM 156 SEISMOGRAPH ROOM 154 RESOURCE ROOM 150A AUTO TUTORIAL ROOM 171 STORAGE 171A LABORATORY RM 179 OFFICE 175 OFFICE 176 OFFICE 180 OFFICE 182 OFFICE 184 STORAGE RM 133 LECTURE HALL 172 SHOP RM 133A PHYSICS CLASSROOM 105 OFFICE 112 OFFICE 114 OFFICE 116 OFFICE 118 OFFICE 118A ADVANCED LAB 126 LECTURE HALL 127 LAB STORAGE RM 126A ADVANCED LAB 128 ADVANCED LAB RM 129 LABORATORY 141 OFFICE 150 OFFICE 148 OFFICE 146 OFFICE 144 WOMEN'S RM 132 MEN'S RM 134 PHYSICS LECTURE HALL 131 LECTURE HALL 145 PREP/STORAGE RM 143 OFFICE 110 OFFICE 186 MINEROLOGY LAB 149 HALLWAY I-N HALLWAY I-L HALLWAY I-G HALLWAY I-K HALLWAY I-F HALLWAY I-W HALLWAY I-D UNISEX RM 136 STORAGE 172A STORAGE 131A VESTIBULE I-A STAIRWELL I-C STAIRWELL I-B OFFICE 142 HALLWAY 1-U STAIRWELL 1-V BDF 138 STAIRWELL 1-S STAIRWELL 1-H STAIRWELL 1-E ELEVATOR 1-J A911 A1 3 0 " 3 0 " 3 5 1 /2 " 2 3 '-5 1 /2 " 6 6 " 20'-5 1/8" 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A901 LEVEL 01 FURNITURE PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 01 FURNITURE PLAN NOTE: FURNITURE IS OWNER FURNISHED AND OWNER INSTALLED, UNLESS NOTED OTHERWISE. THE FOLLOWING LAYOUT IS TO HELP COORDINATE INFRASTURCTURE AND SUPPORT FOR THE FURNITURE. UPDATES WILL BE PROVIDED BY BYUI AT A LATER DATE. A A 1 1 B B C C D D E E F F G G H H J J K K L L M M N N P P 2 2 3 3 4 4 5 5 6 6 7 7 8 8 INSTRUMENT RM 203A CHEMISTRY STOCK RM 213 OFFICE 213A CLASSROOM 270 CLASSROOM 268 MEN'S RM 266 WOMEN'S RM 264 OFFICE 252 OFFICE 253 OFFICE 250 OFFICE 248 OFFICE 246 OFFICE 244 OFFICE 242 OFFICE 240 OFFICE 238 WORK ROOM 243 OFFICE 236 OFFICE 234 OFFICE 239 OFFICE 237 OFFICE 235 OFFICE 233 OFFICE 232 CLASSROOM 255 CLASSROOM 277 OFFICE 259 OFFICE 261 OFFICE 263 OFFICE 265 MEN'S ROOM 226 WOMEN'S ROOM 220 GENERAL CHEM LAB 282 CHEM STOCK RM 282A OFFICE 286 OFFICE 285 OFFICE 289 OFFICE 290 OFFICE 291 OFFICE 292 OFFICE 294 OFFICE 296 OFFICE 298 CHEMISTRY LAB 204 CHEMISTRY LAB 214 CHEMISTRY LAB 210 CHEMISTRY PREP RM 281 CLASSROOM 276 CUST RM 267 BDF RM 280 CUST RM 228 INSTRUMENT RM 203B CLASSROOM 229 CLASSROOM 279 CLASSROOM 297 CLASSROOM 299 CHEMISTRY LAB 203 STORAGE 258 STORAGE RM 277A WORK ROOM 287A SEC/ RECEP RM 287 HALLWAY 2-U HALLWAY 2-D HALLWAY 2-F HALLWAY 2-S LOUNGE 2-V HALLWAY 2-J HALLWAY 2-M SECRETARY/RECEPTION RM 230 HALLWAY 2-K CLASSROOM 260 CLASSROOM 262 HALLWAY 2-L CUST STOR 216 STAIRWELL 2-HELEVATOR 2-G STAIRWELL 2-T HALLWAY 2-B STAIRWELL 2-A STAIRWELL 2-C BIO-CHEMISTRY LAB 272 ALL NEW STALLS, FIXTURES AND PLUMBING TO BE REPLACED TO MATCH EXISTING LAYOUT. NEW TILE WALLS, TILE TBD BA C K S I D E BA C K S I D E FR O N T S I D E FR O N T S I D E CURRENTLY DI WANTER HERE A911 A4 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A902 LEVEL 02 FURNITURE PLAN 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/8" = 1'-0"A1 LEVEL 02 FURNITURE PLAN NOTE: FURNITURE IS OWNER FURNISHED AND OWNER INSTALLED, UNLESS NOTED OTHERWISE. THE FOLLOWING LAYOUT IS TO HELP COORDINATE INFRASTURCTURE AND SUPPORT FOR THE FURNITURE. UPDATES WILL BE PROVIDED BY BYUI AT A LATER DATE. PHOTO STUDIO 51 DARK ROOM 59D COMPUTER LAB 59 EQUIP / CHECK OUT 59A STORAGE 59B STORAGE 51A CHANGING 51B VESTIBULE 0-H CLASSROOM 50 STORAGE 52C PHYSICS LAB 52 ACOUSTICS STUDIO 52B OPTICS LAB 52A OFFICE 57 OFFICE 55 C-16 P-21 P-21 C-16 C-16 C-16 C-16 C-16 P-18 P-14 P-20 VESTIBULE O-A HALLWAY O-C FILM 59E VESTIBULE 59C G-6 G-6 TYP G-1 TYP G-4 P-1 TYP P-2 TYP G-4 P-9 P-12 P-12 P-11 C-13 G-10G-10G-10 G-10 G-10 G-10 G-2 G-12 G-11 TYP TYP TYP TYP G-1 G-4 P-1 P-19 P-19 P-19 G-2 TYP G-8 TYP TYP P-6 P-6 P-6 P-7 P-7 G-8 G-8P-3 P-4 P-4 G-4 G-9G-9 G-8 G-5 G-5 G-5 P-8 G-5 G-5 G-5 G-5 P-16 C-17 P-15 P-15 P-17 P-10 4' - 6" 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A910 EQUIPMENT & FURNITURE PLANS & SCHEDULE 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set 1/4" = 1'-0"A1 LEVEL 00 ENLARGED EQUIPMENT & FURNITURE PLAN FURNITURE SCHEDULE - LEVEL 0 Room # Room Name Type Mark Asset Name Count Existing New CFCI OFCI OFOI Special Requirements 50 CLASSROOM G-11 20 ● ● 50 CLASSROOM G-12 Classroom Chair 40 ● ● 51 PHOTO STUDIO G-6 Classroom Chair 24 ● ● 51 PHOTO STUDIO P-9 Mobile Computer Cart 1 ● ● 52 PHYSICS LAB C-16 Table 2'-6" x 6'-0" 6 ● ● 52 PHYSICS LAB C-17 Table 2'-6" x 4'-0" 1 ● ● 52 PHYSICS LAB G-6 Classroom Chair 12 ● 52 PHYSICS LAB P-18 Table 2'-6" x 4'-0" 1 ● ● 52 PHYSICS LAB P-19 Dividing Wall w/ White Boards 3 52 PHYSICS LAB P-21 Table 3'-6" x 8'-0" 2 ● ● 52A OPTICS LAB G-1 Task Chair 1 ● ● 52A OPTICS LAB G-8 Task Chair 1 ● ● 52A OPTICS LAB P-1 Table 2'-0" x 6'-0" 1 ●● 52A OPTICS LAB P-14 Table 2'-6" x 5'-0" 1 ●● 55 OFFICE G-8 Task Chair 1 ● ● 55 OFFICE G-9 Office Chair 2 ● 55 OFFICE P-12 Work Station w/ Computer 1 ● ● 57 OFFICE G-8 Task Chair 1 ● ● 57 OFFICE G-9 Office Chair 2 ● 57 OFFICE P-12 Work Station w/ Computer 1 ● ● 59 COMPUTER LAB G-1 Task Chair 18 ● ● 59 COMPUTER LAB P-1 Table 2'-0" x 6'-0" 9 ● ● 59 COMPUTER LAB P-2 Table 2'-0" x 3'-0" 3 ● ● 59A EQUIP / CHECK OUT G-8 Task Chair 1 ● ● 59A EQUIP / CHECK OUT P-10 Large Format Printer 1 ● 59A EQUIP / CHECK OUT P-11 Work Station w/ Computer 1 ● 272 BIO-CHEMISTRY LAB C-16 Table 2'-6" x 6'-0" 1 ●● 272 BIO-CHEMISTRY LAB C-17 Table 2'-6" x 4'-0" 24 ● ● 272 BIO-CHEMISTRY LAB G-1 Task Chair 4 ● ● O-C HALLWAY G-10 Bench 6 ● ● FABRIC: DESIGNTEX, STYLE: TILT 3001-801, COLOR: SLATE EQUIPMENT SCHEDULE - LEVEL 0 Room # Room Name Type Mark Asset Name Count Existing New CFCI OFCI OFOI Special Requirements 51 PHOTO STUDIO G-4 Computer 1 ●● 51 PHOTO STUDIO G-5 Waste Bin 2 ●● 52 PHYSICS LAB G-2 Tank 15 ●● 52 PHYSICS LAB G-5 Waste Bin 2 ●● 52 PHYSICS LAB P-15 Vacuum Fusion Pump 2 ●● 52 PHYSICS LAB P-16 Aneealing Oven 1 ●● 52 PHYSICS LAB P-17 Geranium Lithium Detector 1 ●● 52 PHYSICS LAB P-20 NitrogenTank 1 ●● 52A OPTICS LAB G-4 Computer 1 ●● 59 COMPUTER LAB G-4 Computer 18 ●● 59 COMPUTER LAB G-5 Waste Bin 1 ●● 59 COMPUTER LAB P-3 Photo Printer 10 ●● 59 COMPUTER LAB P-4 Dry Mount Press 2 ●● 59 COMPUTER LAB P-5 Flatbed Scanner 8 ●● 59A EQUIP / CHECK OUT G-4 Computer 1 ●● 59B STORAGE C-13 Refrigerator 1 ●● 59D DARK ROOM G-5 Waste Bin 1 ●● 59D DARK ROOM P-6 Photo Enlarger 3 ●● 59D DARK ROOM P-7 UV Equipment 2 ●● 59D DARK ROOM P-8 NitrogenTank 1 ●● NOTE: FURNITURE IS OWNER FURNISHED AND OWNER INSTALLED, UNLESS NOTED OTHERWISE. THE FOLLOWING LAYOUT IS TO HELP COORDINATE INFRASTURCTURE AND SUPPORT FOR THE FURNITURE. UPDATES WILL BE PROVIDED BY BYUI AT A LATER DATE. C-9 C-10 C-12 C-11 C-14 C-15 C-17 C-17C-17 C-17 C-17 C-17 C-17 C-17 C-17 C-17 C-17 C-17 C-17 C-17C-17 C-17C-17 C-17C-17C-17C-17 C-17 C-17 C-17 C-19 C-20 C-21 C-22 C-22 C-23 C-24 C-25 C-26 C-27 C-28 C-29 C-30 C-31 C-33 C-32 C-18 C-18 C-18 C-18C-18 C-18 C-18 C-18 C-18 C-18 C-8 G-5 G-5C-4 G-4 G-4 G-3 C-3 G-2 G-2 G-2 C-5 C-6 G-4 C-7 G-2 G-2 G-2 G-1 G-1 G-1 G-1 C-1 C-2 C-16 C-13 C-13 G-5 TYP 4' - 0" T Y P 2 ' - 6 " BIO-CHEMISTRY LAB 272 A601 C1 A601 B2 A601 B3 G-7 G-6 PHYSICAL GEOLOGY ROOM 158 TYP TYP 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 002294 4/28/2023 A911 EQUIPMENT & FURNITURE PLANS & SCHEDULES 22.0540 04/28/2023 281 S Center St, Rexburg, ID 83440 Romney 2023 Remodel Bid Set FURNITURE SCHEDULE - LEVEL 2 Room # Room Name Type Mark Asset Name Count Existing New CFCI OFCI OFOI Special Requirements 272 BIO-CHEMISTRY LAB C-16 Table 2'-6" x 6'-0" 1 ●● 272 BIO-CHEMISTRY LAB C-17 Table 2'-6" x 4'-0" 24 ● ● 272 BIO-CHEMISTRY LAB G-1 Task Chair 4 ● ● EQUIPMENT SCHEDULE - LEVEL 2 Room # Room Name Type Mark Asset Name Count Existing New CFCI OFCI OFOI Special Requirements 272 BIO-CHEMISTRY LAB C-1 Balance 1 ●● 272 BIO-CHEMISTRY LAB C-2 PH Meter 1 ●● 272 BIO-CHEMISTRY LAB C-3 Chromatograph Mass Spec 1 ●● 272 BIO-CHEMISTRY LAB C-4 Portable Chromatograph Mass Spec 1 ●● 272 BIO-CHEMISTRY LAB C-5 RO System 1 ●● 272 BIO-CHEMISTRY LAB C-6 Visible Spectrophotometer 1 ●● 272 BIO-CHEMISTRY LAB C-7 Chromatograph 1 ●● 272 BIO-CHEMISTRY LAB C-8 Floor Shaker 1 ●● 272 BIO-CHEMISTRY LAB C-9 FPLC 1 ●● 272 BIO-CHEMISTRY LAB C-10 Fraction Collector 1 ●● 272 BIO-CHEMISTRY LAB C-11 Sonicator Power Supply 1 ●● 272 BIO-CHEMISTRY LAB C-12 Sonicator 1 ●● Compressed air quick connect , see mechanical drawings 272 BIO-CHEMISTRY LAB C-13 Refrigerator 2 ●● 272 BIO-CHEMISTRY LAB C-14 Freezer - Negative 80 1 ●● 272 BIO-CHEMISTRY LAB C-15 Freezer - Negative 20 1 ●● 272 BIO-CHEMISTRY LAB C-18 Microcentrifuge 10 ●● 272 BIO-CHEMISTRY LAB C-19 Autoclave 1 ●● 240V, see electrical 272 BIO-CHEMISTRY LAB C-20 Tube Furnace 1 ●● 208V, see electrical 272 BIO-CHEMISTRY LAB C-21 Gas Mixing Manifold 1 ●● 272 BIO-CHEMISTRY LAB C-22 Nano Drop 2 ●● 272 BIO-CHEMISTRY LAB C-23 Thermocycler 1 ●● 272 BIO-CHEMISTRY LAB C-24 Micro Centrifuge 1 ●● 272 BIO-CHEMISTRY LAB C-25 Hot Block 1 ●● 272 BIO-CHEMISTRY LAB C-26 Hot Block 1 ●● 272 BIO-CHEMISTRY LAB C-27 Eisa Plate Reader 1 ●● 272 BIO-CHEMISTRY LAB C-28 Spectrophotomer 1 ●● 272 BIO-CHEMISTRY LAB C-29 Gel Imaging 1 ●● 272 BIO-CHEMISTRY LAB C-30 White Light Gel Imaging 1 ●● 272 BIO-CHEMISTRY LAB C-31 Rocking Platform 1 ●● 272 BIO-CHEMISTRY LAB C-32 Centrifuge 1 ●● 272 BIO-CHEMISTRY LAB C-33 Incubator 1 ●● 272 BIO-CHEMISTRY LAB G-2 Tank 6 ●● 272 BIO-CHEMISTRY LAB G-3 CPU 1 ●● 272 BIO-CHEMISTRY LAB G-5 Waste Bin 3 ●● 1/4" = 1'-0"A4 LEVEL 02 ENLARGED EQUIPMENT & FURNITURE PLAN 1/4" = 1'-0"A1 LEVEL 01 ENLARGED EQUIPMENT & FURNITURE PLAN FURNITURE SCHEDULE - LEVEL 1 Room # Room Name Type Mark Asset Name Count Existing New CFCI OFCI OFOI Special Requirements 158 PHYSICAL GEOLOGY ROOM G-6 Classroom Chair 36 ●● 158 PHYSICAL GEOLOGY ROOM G-7 Geology Table 18 ● ● NOTE: FURNITURE IS OWNER FURNISHED AND OWNER INSTALLED, UNLESS NOTED OTHERWISE. THE FOLLOWING LAYOUT IS TO HELP COORDINATE INFRASTURCTURE AND SUPPORT FOR THE FURNITURE. UPDATES WILL BE PROVIDED BY BYUI AT A LATER DATE. STRUCTURAL GENERAL NOTES BASIS OF DESIGN 1.GOVERNING BUILDING CODE...............................................2018 IBC 2.OCCUPANCY CATEGORY.......................................................III 3.LOAD COMBINATIONS: ASD -GRAVITY AND LATERAL.......................................1605.3.1 4.GRAVITY DESIGN: DEAD LOAD ROOF................................................................................NA FLOOR..............................................................................60 PSF PARTITIONS.....................................................................20 PSF LIVE LOAD (UNIFORMLY DISTRIBUTED LOADS) ROOMS..............................................................................80 PSF FIRST FLOOR CORRIDORS.............................................100 PSF CORRIDORS ABOVE FIRST FLOOR................................80 PSF LIVE LOAD (CONCENTRATED LOADS) ALL AREAS.........................................................................2000 LBS ROOF LIVE LOAD (NOT CONCURRENT WITH ROOF SNOW LOAD)............20 PSF ROOF SNOW LOAD GROUND SNOW LOAD...................................................NA 5.LATERAL DESIGN: WIND DESIGN PER ASCE 7-16 ULTIMATE DESIGN WIND SPEED..................................NA SEISMIC DESIGN SEISMIC DESIGN PROCEDURE.....................................NA GENERAL 1.THE GENERAL CONTRACTOR SHALL: A.BECOME FAMILIAR WITH ALL PORTIONS OF THE CONTRACT DOCUMENTS AND INSURE THAT ALL SUBCONTRACTORS ARE FAMILIAR WITH THOSE PORTIONS PERTAINING TO THEIR AREA OF WORK. NO DEVIATIONS WILL BE ALLOWED UNLESS AGREED UPON BY ALL PARTIES IN WRITING PRIOR TO CONSTRUCTION FABRICATION. B.VERIFY ALL DIMENSIONS AND ELEVATIONS. COORDINATE ALL DOORS, WINDOWS, NON- BEARING INTERIOR AND EXTERIOR WALLS, ELEVATIONS, SLOPES, STAIRS, CURBS, DRAINS, RECESSES, DEPRESSIONS, RAILINGS, WATERPROOFING, FINISHES, CHAMFERS, KERFS, ETC. C.FIELD VERIFY ALL SITE CONDITIONS AND IMMEDIATELY NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER REGARDING ACTUAL CONDITIONS AT THE SITE WHICH ARE NOT PER THE DRAWINGS. D.COORDINATE ALL WORK BETWEEN THE VARIOUS TRADES AND SUBCONTRACTORS. REPORT ANY MODIFICATIONS TO THE STRUCTURAL PORTION OF THE BUILDING BY OTHER TRADES TO THE ARCHITECT AND STRUCTURAL ENGINEER. E.BE RESPONSIBLE FOR SAFETY AND PROTECTION IN AND AROUND THE JOB SITE AND/OR ADJACENT PROPERTIES. F.REPORT PROGRESS OF WORK TO ARCHITECT AND STRUCTURAL ENGINEER. G.COORDINATE AND VERIFY ROOF, FLOOR, AND WALL OPENINGS REQUIRED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND/OR OTHER DRAWINGS PRIOR TO CONSTRUCTION. REPORT OPENINGS REQUIRED WHICH ARE NOT SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW. h.COORDINATE ANY CONSTRUCTION SITUATION NOT COVERED BY THESE PLANS, GENERAL NOTES, OR SPECIFICATIONS WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 2.CONTRACT DOCUMENTS: A.REFER TO THE SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES OR THE DRAWINGS. B.DETAILS, SECTIONS AND NOTES SHOWN ON THE STRUCTURAL DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO ALL SIMILAR SITUATIONS ELSEWHERE, UNLESS NOTED OR SHOWN OTHERWISE. C.THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE OVER SHOP DRAWINGS UNLESS SPECIFICALLY NOTED OTHERWISE. D.INFORMATION ON DRAWINGS INDICATING EXISTING CONDITIONS IS BASED ON BEST PRESENT KNOWLEDGE, BUT MAY NOT BE ENTIRELY ACCURATE AND MUST BE FIELD VERIFIED. 3.BUILDING CODE COMPLIANCE: A.INSPECTION, TESTING, CONSTRUCTION, WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND STANDARDS. ASTM, IBC, AND OTHER DESIGNATIONS SHALL BE AS AMENDED TO LATEST DATE UNLESS NOTED OTHERWISE. 4.CONSTRUCTION SEQUENCE, SHORING, AND BRACING REQUIREMENTS: A.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE METHOD, MEANS, AND SEQUENCE OF ALL STRUCTURAL ERECTION EXCEPT WHEN SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING TO PROVIDE ADEQUATE VERTICAL AND LATERAL SUPPORT DURING ERECTION. THIS SHORING AND BRACING SHALL REMAIN IN PLACE UNTIL ALL PERMANENT MEMBERS ARE PLACED AND ALL FINAL CONNECTIONS ARE COMPLETED, INCLUDING ALL ROOF AND FLOOR ATTACHMENTS. B.SHORING AND SUPPORTING FORM WORK FOR SUSPENDED CONCRETE OR MASONRY MATERIAL SHALL REMAIN IN PLACE AND SHALL NOT BE REMOVED UNTIL THE STRUCTURAL MEMBERS HAVE ACQUIRED SUFFICIENT STRENGTH TO SAFELY SUPPORT THEIR OWN WEIGHT AND ANY ADDITIONAL CONSTRUCTION, STORAGE, AND/OR OTHER LOADS TO WHICH THE MAY BE SUBJECTED. 5.OMISSIONS AND/OR CONFLICTS: A.OMISSIONS IN AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER AND SHALL BE RESOLVED BEFORE PROCEEDING WITH ANY WORK INVOLVED. B.IN CASE OF CONFLICTS IN THE STRUCTURAL WORK, THE MOST STRINGENT REQUIREMENTS, AS DIRECTED BY THE ARCHITECT AND STRUCTURAL ENGINEER, SHALL BE IMPLEMENTED AT NO ADDITIONAL COST TO THE OWNER. 6.MISCELLANEOUS: A.DURING AND AFTER CONSTRUCTION, THE CONTRACTOR AND/OR OWNER SHALL KEEP THE LOADS ON THE STRUCTURE WITHIN THE LIMITS OF THE DESIGN. B.OBSERVATION VISITS TO THE SITE BY REPRESENTATIVES OF THE ARCHITECT AND/OR STRUCTURAL ENGINEER SHALL NOT BE CONSTRUED AS INSPECTION NOR APPROVAL OF CONSTRUCTION. C.ALL WORK SHALL BE DONE IN ACCORDANCE WITH OSHA REQUIREMENTS. ANY CONFLICTS BETWEEN THESE DOCUMENTS AND OSHA REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER BEFORE PROCEEDING WITH WORK. STRUCTURAL STEEL 1.CODES AND STANDARDS: A.STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL COMPLY WITH: I.THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (AISC 360-16)", WITH "COMMENTARY". II.AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES (AISC 303-10)" EXCLUDING SECTIONS 1.5.1,4.4,7.5.4, AND 7.13.3. III.AMERICAN WELDING SOCIETY (AWS-D1.1) "STRUCTURAL WELDING CODE -STEEL", EXCLUDING ITEMS CONFLICTING WITH AISC REQUIREMENTS. 2.MATERIALS: A.STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992. OTHER STRUCTURAL STEEL SHAPES, PLATES, ANGLES, ETC. SHALL CONFORM TO ASTM A36. RUSSIAN STEEL IS NOT PERMITTED. B.HOLLOW STRUCTURAL SECTIONS SHALL CONFORM TO ASTM A500, GRADE C, WITH A MINIMUM YIELD STRENGTH Fy = 50 KSI. C.HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325. ANCHOR RODS SHALL HAVE HEADED STUDS AND SHALL CONFORM TO ASTM F1554. ALL OTHER BOLTS SHALL CONFORM TO ASTM A307 OR BETTER. 3.CONSTRUCTION: A.FABRICATION SHALL BE DONE IN AN APPROVED FABRICATOR'S SHOP. B.CAMBER IN BEAMS SHALL BE AS INDICATED ON PLANS. C.PROVIDE A SHOP COAT OF PAINT ON ALL STEEL ITEMS, EXCEPT AT AREAS OF WELDING AND/OR BOLTING. D.USE HIGH STRENGTH (8000 PSI MINIMUM AT 28 DAY), NON-SHRINK, LIQUID EPOXY GROUT BENEATH ALL STEEL BASE PLATES AND BEARING PLATES. MIX GROUT WITH SAND OR PEA GRAVEL AS RECOMMENDED BY THE MANUFACTURER. PLACE GROUT AS SOON AS STEEL MEMBER HAS BEEN PROPERLY POSITIONED AND ALIGNED. 4.BOLTED CONNECTIONS: A.STEEL TO STEEL BOLTED CONNECTIONS SHALL BE MADE WITH ASTM A325 HIGH STRENGTH BOLTS AND NUTS, UNLESS NOTED OTHERWISE. BOLTS SHALL CARRY THE IDENTIFYING MARK OF THREE (3) RADIAL LINES. B.ALL OTHER BOLTED CONNECTIONS SHALL BE MADE WITH BOLTS AND NUTS CONFORMING TO ASTM A307 UNLESS NOTED OTHERWISE. C.BOLTS SHALL BE 3/4" DIAMETER, TYPICAL, UNLESS NOTED OTHERWISE. STANDARD SPACING SHALL BE 3" O.C. AND STANDARD EDGE DISTANCE SHALL BE 1.1/2", TYPICAL, UNLESS NOTED OTHERWISE. D.BOLT SHALL BE BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED UNLESS NOTED OTHERWISE. E.BOLTED CONNECTIONS SHALL BE TIGHTENED SNUG TIGHT AND SHALL HAVE WASHERS AS REQUIRED BY AISC UNLESS NOTED OTHERWISE. F.ENLARGING OF HOLES SHALL BE ACCOMPLISHED BY MEANS OF REAMING. DO NOT USE A TORCH ON ANY BOLT HOLES. 5.WELDED CONNECTIONS: A.WELDING AND GAS CUTTING SHALL BE DONE PER AWS. B.WELDERS SHALL BE CURRENTLY CERTIFIED ACCORDING TO AWS. ALL WELDING PROCEDURES SHALL BE PRE-QUALIFIED. WELDERS SHALL FOLLOW WELDING PROCEDURES. C.WELDED CONNECTIONS SHALL BE MADE USING LOW HYDROGEN MATCHING FILLER MATERIAL ELECTRODES, UNLESS NOTED OTHERWISE. D.WELDS SHALL HAVE THE SLAG REMOVED. E.FULL PENETRATION WELDS, SHOP OR FIELD, SHALL HAVE BACKER BARS REMOVED, BE BACK GOUGED, AND REWELDED PER AWS TO HAVE FULL PENETRATION WELD. 7.SUBMITTALS: A.THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION, ERECTION, INSTALLATION, OR OTHERWISE BEING INCORPORATED INTO THE WORK. STRUCTURAL STEEL SHOP DRAWINGS. WELDING PROCEDURES AND CERTIFICATIONS. B.A MINIMUM OF TWO WEEKS SHALL BE ALLOWED FOR THE REVIEW OF ALL SUBMITTALS BY THE ARCHITECT AND STRUCTURAL ENGINEER. C.REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER IN WRITING. REASON(S) FOR THE REQUEST AND COST DIFFERENTIALS SHALL BE INCLUDED IN THE REQUESTS. SUBSTITUTIONS ARE NOT ALLOWED UNLESS APPROVED IN WRITING BY THE ARCHITECT AND STRUCTURAL ENGINEER. 8.DEFERRED SUBMITTALS: A.THE FOLLOWING ITEMS REQUIRING DEFERRED SUBMITTALS ARE LISTED BELOW. THESE ITEMS SHALL BE DESIGNED AND FABRICATED BY THE MANUFACTURER ACCORDING TO THE SPECIFICATIONS GIVEN IN THE CONTRACT DOCUMENTS. NO DEFERRED SUBMITTALS SOILS 1.SOILS REPORT BY: NA 2.SOILS REPORT NUMBER AND DATE:NA 3.SOIL BEARING PRESSURE:NA QUALITY ASSURANCE PLAN FOR STRUCTURE 1.INSPECTION: A.THE OWNER SHALL PROVIDE SPECIAL INSPECTION BY QUALIFIED INSPECTORS FOR THE FOLLOWING TYPES OF CONSTRUCTION IN ACCORDANCE WITH IBC, SECTION 1704 AND 1707, THE SPECIFICATIONS, AND THE ATTACHED TABLES INCLUDED IN THESE GENERAL NOTES. BOLTING: ALL HIGH STRENGTH BOLTS AND BOLTS EMBEDDED IN CONCRETE AND/OR EPOXY. SEE ATTACHED TABLE LABELED REQUIRED VERIFICATION AND INSPECTION OF CONCRETE/STEEL CONSTRUCTION. WELDING: ALL SHOP AND FIELD WELDS. INSPECTOR SHALL BE AWS-QC1 CERTIFIED. SEE ATTACHED TABLE LABELED REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION. 2.TESTING: A.THE OWNER SHALL PROVIDE TESTING BY QUALIFIED TESTING AGENCIES FOR THE FOLLOWING TYPES OF CONSTRUCTION IN ACCORDANCE WITH IBC, SECTION 1708 AND THE SPECIFICATIONS. BOLTING: PROPER INSTALLATION AND CORRECT TORQUE AND/OR TENSION. WELDING:TYPE, SIZE, LENGTH, AND QUALITY OF ALL SHOP AND FIELD WELDS BY APPROVED METHODS. ULTRASONICALLY TEST ALL COMPLETE PENETRATION WELDS. 3.STRUCTURAL OBSERVATIONS: A.THE STRUCTURAL ENGINEER SHALL BE NOTIFIED TO PERFORM STRUCTURAL OBSERVATIONS AT SIGNIFICANT STAGES OF CONSTRUCTION.: B.THE STRUCTURAL ENGINEER SHALL PROVIDE A COPY OF THE OBSERVATION REPORT TO THE ARCHITECT FOR FURTHER DISTRIBUTION. 4.THE CONTRACTOR SHALL: A.SUBMIT A STATEMENT OF RESPONSIBILITY TO THE OWNER AND BUILDING OFFICIAL PRIOR TO COMMENCING WORK ON STRUCTURE THAT INCLUDES AWARENESS OF THE QUALITY ASSURANCE PLAN REQUIREMENTS, ACKNOWLEDGMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE TO CONSTRUCTION DOCUMENTS, PROCEDURES FOR EXERCISING CONTROL, METHOD AND FREQUENCY OF REPORTING, AND IDENTIFICATION AND QUALIFICATIONS OF PERSONNEL IN CHARGE OF CONTROL. B.CORRECT ALL WORK FOUND TO BE DEFICIENT AT NO ADDITIONAL COST TO THE OWNER. C.COORDINATE ALL THE REQUIRED INSPECTIONS, TESTING, AND/OR STRUCTURAL OBSERVATIONS OF THE QUALITY ASSURANCE PLAN. DO NOT PROCEED WITH SUBSEQUENT WORK UNTIL THE REQUIRED INSPECTIONS, TESTING, AND STRUCTURAL OBSERVATIONS HAVE BEEN PROVIDED. NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER AT LEAST 48 HOURS PRIOR TO ANY REQUIRED OBSERVATIONS. D.PROVIDE COPIES OF THE DAILY INSPECTION REPORTS AND ALL TESTING RESULTS TO THE ARCHITECT, STRUCTURAL ENGINEER, OWNER, AND BUILDING OFFICIAL. POST-INSTALLED ANCHORS 1.EPOXY ANCHORS: A.THE FOLLOWING EPOXY ADHESIVES SYSTEMS SHALL BE ALLOWED: FOR CONCRETE: SIMPSON SET-XP HILTI HIT-RE 500-V3 HILTI HIT-RE 100 FOR SOLID GROUTED MASONRY: SIMPSON SET HILTI HIT HY 200 FOR UNGROUTED MASONRY: SIMPSON ET HILTI HY 270 B.ANCHOR RODS SHALL BE ASTM A-307, THREADED AND GALVANIZED, AND THE DIAMETER AS INDICATED ON PLAN. C.SCREEN TUBES SHALL BE USED AT UNGROUTED MASONRY UNITS. D.ALL ANCHORS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. AS A MINIMUM BOLT HOLES SHALL BE WIRE BRUSHED AND CLEANED WITH COMPRESSED AIR. E.INSTALLATION OF ADHESIVE ANCHORS THAT ARE TO BE UNDER SUSTAINED TENSION LOADING IN HORIZONTAL TO VERTICALLY OVERHEAD ORIENTATION SHALL BE DONE BY A CERTIFIED ADHESIVE ANCHOR INSTALLER (AAI) AS CERTIFIED THROUGH ACI AND IN ACCORDANCE WITH ACI 318-2014 (Section 17.8.2.2). PROOF OF CURENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO COMMENCEMENT OF INSTALLATION. F.PER ACI 318-2014 (Section 17.1.2) ADHESIVE ANCHORS SHALL BE INSTALLLED IN CONCRETE HAVING A MINIMUM AGE OF 21 DAYS AT TIME OF ANCHOR INSTALLATION. FOR INSTALLATIONS SOONER THAN 21 DAYS CONSULT ADHESIVE MANUFACTURER. G.IF TEMPERATURE OF BASE MATERIAL AT TIME OF ADHESIVE INSTALLATION IS AT 45 DEGREES (FAHRENHEIT) OR LESS, AN “ACRYLIC” (COLD WEATHER) ADHESIVE IS REQUIRED –ie DEWALT AC200+, HILTI HY200, SIMPSON AT-XP. 2.MECHANICAL ANCHORS A.THE FOLLOWING MECHANICAL ANCHORS SHALL BE ALLOWED: SIMPSON TITEN HD HILTI KWIK HUS-EZ B.ALL ANCHORS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. AS A MINIMUM BOLT HOLES SHALL BE WIRE BRUSHED AND CLEANED WITH COMPRESSED AIR. 3.SUBSTITUTES: CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR APPROVAL TO THE ARCHITECT AND STRUCTURAL ENGINEER. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ???? SE-001 GENERAL NOTES BE23002 04/08/2023 Enter address here ROMNEY 2023 REMODEL Project Status 04/28/2023 A 1 B C D E F GH J K L MN P 2 3 4 5 6 7 8 L6X6X5/16 L6X6X5/16 L6X6X5/16 L6X6X5/16 L6X6X3/8 H SS 6 X4X1/4 A1 SE-501 A1 SE-501 A2 SE-501 A2 SE-501 L6X6X5/16 L6X6X5/16 A2 SE-501 A3 SE-501 A4 SE-501 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ???? SE-101 LEVEL 1 FRAMING PLAN BE23002 04/08/2023 Enter address here ROMNEY 2023 REMODEL Project Status 1/8" = 1'-0"SE-101 A1 Level 1 04/28/2023 A 1 B C D E F GH J K L MN P 2 3 4 5 6 7 8 PROVIDE L6X6X3/16 LINTEL FOR HOOD PENETRATIONS. BEAR 6" ON MASONRY EACH SIDE. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ???? SE-102 ROOF FRAMING PLAN BE23002 04/08/2023 Enter address here ROMNEY 2023 REMODEL Project Status 1/8" = 1'-0"SE-102 A1 ROOF 04/28/2023 EXISTING WALL -EXTERIOR SIDE AREA TO BE REMOVED TITEN TURBO, TYPICAL COMPRESSION FLANGE BRACING. WINDOW FRAME ANGLE SEE PLAN. MITER AT CORNERS AND WELD TOGETHER. TITEN TURBO ON BOTH LEGS OF "COLUMN" ANGLES, SEE DETAILS A2- A4. 0' - 1 1 / 2 " 0' - 1 1/2" 0' - 4" NEW OPENING 0' - 1 1 / 2 " 0' - 2" END 0' - 8" TYP.¼"ØX1¾" TITEN TURBOB1 SE-501 ANGLE, SEE PLAN FOR SIZE, USE ON ALL 3 SIDES OF DOOR. 1/4"Ø TITEN TURBO MASONRY SCREWS AT 8"O.C. EMBED 1.25". BOTH FACES FOR VERTICAL MEMBERS ELEVATION B1 SE-501 MITER AT CORNERS AND BUTT WELD. ANGLE, SEE PLAN FOR SIZE, USE ON ALL 3 SIDES OF DOOR. 1/4"Ø TITEN TURBO MASONRY SCREWS AT 8"O.C. EMBED 1.25". BOTH FACES FOR VERTICAL MEMBERS ELEVATION B1 SE-501 L8X4X1/2 BY 7.5" WITH (2) 5/8"ØX5.5" HILTI KWIK-EZ BOLTS SPACED 5"O.C. MITER AT CORNERS AND BUTT WELD. ANGLE, SEE PLAN FOR SIZE, USE ON ALL 3 SIDES OF DOOR. 1/4"Ø TITEN TURBO MASONRY SCREWS AT 8"O.C. EMBED 1.25". BOTH FACES FOR VERTICAL MEMBERS ELEVATION B1 SE-501 1/4 EXISTING MASONRY. SHORE AS REQUIRED. MITER AT CORNERS AND BUTT WELD. COLUMN, SEE PLAN WITH 1/2"X4.5"X7" BASE PLATE WITH (2) 3/4" TITEN HD BOLTS. SHIM AS REQUIRED TO LEVEL. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ???? SE-501 DETAILS BE23002 04/08/2023 Enter address here ROMNEY 2023 REMODEL Project Status 1" = 1'-0"SE-501 B1 3/4" = 1'-0"SE-501 A1 3/4" = 1'-0"SE-501 A2 3/4" = 1'-0"SE-501 A3 3/4" = 1'-0"SE-501 A4 04/28/2023 GR I L L E A N D D I F F U S E R S C H E D U L E SY M B O L D E S C R I P T I O N M A N U F A C T U R E R M O D E L R E M A R K S S- 1 C E I L I N G D I F F U S E R - L A Y - I N K R U E G E R 1 4 0 0 - S- 2 C E I L I N G D I F F U S E R - S U R F A C E K R U E G E R S H - R- 1 C E I L I N G R E T U R N - L A Y - I N K R U E G E R 6 4 9 0 - R- 2 C E I L I N G R E T U R N - S U R F A C E K R U E G E R 6 4 9 0 - E- 1 S U R F A C E M O U N T C E I L I N G E X H A U S T K R U E G E R E G C 5 - E- 2 L A Y - I N C E I L I N G E X H A U S T K R U E G E R E G C 5 - SE E S P E C I F I C A T I O N S E C T I O N 2 3 VA R I A B L E V O L U M E A I R B O X E S W I T H R E H E A T ( V A V R ) S E L E C T ION CHART SY S T E M A I R P R E S S U R E C O I L SY M B O L T I T U S C F M T I T U S O P E R A T I N G D R O P W / 1 R O W D I M E N S I O N REMARKS SIZ E R A N G E M O D E L S T A T I C I N . W . C . C O I L I N . W . C . I N C H . VA V R _ 6 0 - 3 4 9 D E S V 0 . 7 5 0 . 3 0 1 2 " x 8 " VA V R _ 8 3 5 0 - 5 9 9 D E S V 0 . 7 5 0 . 3 0 1 2 " x 1 0 " VA V R _ 9 6 0 0 - 7 4 9 D E S V 0 . 7 5 0 . 3 0 1 4 " x 1 2 " - 1 / 2 " VA V R _ 1 0 7 5 0 - 9 9 9 D E S V 0 . 7 5 0 . 3 0 1 4 " x 1 2 " - 1 / 2 " VA V R _ 1 2 1 0 0 0 - 1 3 4 9 D E S V 0 . 7 5 0 . 3 0 1 6 " x 1 5 " VA V R _ 1 4 1 3 5 0 - 1 8 9 9 D E S V 0 . 7 5 0 . 3 0 2 0 " x 1 7 " - 1 / 2 " VA V R _ 1 6 1 9 0 0 - 2 3 9 9 D E S V 0 . 7 5 0 . 3 0 2 4 " x 1 8 " VA V R _ 2 4 x 1 6 2 4 0 0 - 4 8 0 0 D E S V 0 . 7 5 0 . 3 0 3 8 " x 1 8 " CA B I N E T H E A T E R SY M B O L NO M I N A L A I R FL O W C F M TY P E HE A T I N G C O I L S TRANE MODEL R E M A R K S # O F RO W S BT U H EN T . W T R TE M P F ° LV G . W T R TE M P F ° EN T . A I R TE M P F ° LVG. AIR TEMP F°GPMMAXPRESS DROP FT.VOLTS H E R T Z P H A S E CH - 1 47 0 CE I L I N G R E S S E D 4 50 , 0 0 0 18 0 16 0 3 0 100 5.2 3.7 115 6 0 1 CW00458 1, 2 CH - 2 47 0 CE I L I N G R E S S E D 4 50 , 0 0 0 18 0 1 6 0 3 0 1 0 0 5 . 2 3.7 115 6 0 1 CW00458 1, 2 CH - 3 47 0 CE I L I N G R E S S E D 4 50 , 0 0 0 18 0 1 6 0 3 0 1 0 0 5 . 2 3.7 115 6 0 1 CW00458 1, 2 1. P R O V I D E W / F A C T O R Y D I S C O N N E C T 2. 3 5 % P R O P Y L E N E G L Y C O L SE E S P E C I F I C A T I O N 2 3 VA R I A B L E V O L U M E W I T H R E H E A T ( V A V R ) BA L A N C E M I N I M U M M A X . HE A T I N G C O I L 3 0 % P R O P Y L E N E G L Y C O L MIN. SY M B O L A I R F L O W A I R F L O W A I R F L O W H T G . C A P A C I T Y GP M EW T M I N M A X . P R E S S U R E T I T U S I N L E T REMARKS CL G . C F M C F M H T G . C F M B T U / H R D E G F . R O W S D R O P , F T . W . C . S I ZE S I Z E I N . VA V R - 0 - C 1 8 0 0 3 2 0 7 6 5 2 7 , 5 7 1 1 . 9 1 8 0 2 0 . 6 1 4 1 4 VA V R - 5 0 1 3 7 0 3 2 0 3 2 0 1 0 , 1 6 6 0 . 7 1 8 0 1 0 . 0 1 4 1 4 VA V R - 5 1 1 3 0 0 2 3 5 2 3 5 4 , 4 6 8 0 . 5 1 8 0 1 0 . 1 1 2 1 2 VA V R - 5 2 1 1 7 0 2 3 5 3 0 0 1 0 , 8 3 3 0 . 8 1 8 0 1 0 . 3 1 2 1 2 VA V R - 5 2 A 5 6 5 1 0 5 1 5 0 5 , 4 3 3 0 . 5 1 8 0 1 0 . 3 8 8 VA V R - 5 5 1 3 0 6 0 1 0 0 1 , 8 3 1 0 . 5 1 8 0 1 0 . 3 6 6 VA V R - 5 7 1 3 0 6 0 1 0 0 1 , 8 3 1 0 . 5 1 8 0 1 0 . 3 6 6 VA V R - 5 9 2 2 9 5 4 2 0 4 2 0 7 , 7 8 2 0 . 5 1 8 0 1 0 . 1 1 6 1 6 VA V R - 5 9 A 7 4 0 1 3 5 1 3 5 2 , 5 1 1 0 . 5 1 8 0 1 0 . 1 9 9 VA V R - 5 9 D 4 3 0 1 0 5 1 0 5 1 , 9 6 5 0 . 5 1 8 0 1 0 . 3 8 8 VA V R - 6 4 9 5 0 1 6 5 6 8 0 2 4 , 4 6 1 1 . 7 1 8 0 2 0 . 6 1 0 1 0 RO O M S E R V I C E R E Q U I R E M E N T S RO O M M A X R E Q U I R E D SU P P L Y A I R GE N E R A L R O O M E X H A U S T A I R FU M E H O O D E X H A U S T SNORKEL EXHAUST AIR CABINET EXHAUST MISC. RO O M R O O M N A M E S Q U A R E R E T U R N C O O L I N G R O O M A I R V A L V E M A X . D ES I G N M I N . D E S I G N H E A T I N G M A X . P R E S S . T I T U S V A V B O X S I Z E P H O E N I X V A L V E H E A T I N G C O I L A I R V A L V E M A X . M I N . M A X . PR E S S . P H O E N I X A I R V A L V E M A X . M I N . M A X . P R E S S . P H O E N I X S N O RK E L A I R V A L V E M A X . M I N . M A X . P R E S S . P H O E N I X Q T Y . T O T A L E X H AUST ROOM RECYCLE REMARKS NO . FO O T A G E A I R C F M C F M O F F S E T SY M B O L ( ' S ) CF M C F M C F M DR O P ( I N . ) CO L D H O T B O X S I Z E C O I L S I Z E B T U / H R G P M SY M B O L ( ' S ) CF M C F M D R O P V A L V E S I Z E SY M B O L ( ' S ) CF M C F M D R O P V A L V E S I Z E S I Z E SY M B O L ( ' S ) CFM C F M D R O P V A L V E S I Z E C F M P R E S S U R E A I R 28 2 G E N E R A L C H E M . L A B 1 7 7 7 0 2 6 0 0 2 9 0 (E ) - M A V - 2 8 2 B 22 1 5 8 3 5 1 3 5 0 0 . 7 5 - - 2 x 1 2 4 2 " x 1 6 " 6 1 , 1 3 4 6 . 1 E X V - 2 8 2 A 9 3 0 0 0 . 75 1 2 (E ) - E X V - 2 8 2 B 78 5 3 2 5 0 . 7 5 1 0 - - - - - - 1 1 0 - N E G . N O (E ) - M A V - 2 8 2 B 22 1 5 8 3 5 1 3 5 0 0 . 7 5 2x 1 2 4 2 " x 1 6 " 6 1 , 1 3 4 6 . 1 (E ) - E X V - 2 8 2 B 78 5 3 2 5 0 . 7 5 1 0 EX V - 2 8 2 D 0.7 5 EX V - 2 8 2 E 0.7 5 8 (E ) - E X V - 2 8 2 B 78 5 3 2 5 0 . 7 5 1 0 FOR RE-BALANCE ONLY (E ) - E X V - 2 8 2 B 78 5 3 2 5 0 . 7 5 1 0 (E ) - E X V - 2 8 2 B 78 5 3 2 5 0 . 7 5 1 0 (E ) - E X V - 2 8 2 B 78 5 3 2 5 0 . 7 5 1 0 RM . T O T A L 44 3 0 1 6 7 0 2 7 0 0 47 1 0 1 9 5 0 10 27 2 B I O - C H E M I S T R Y 1 7 5 2 0 1 6 5 0 3 0 0 M A V - 2 7 2 1 6 6 5 3 6 0 9 0 0 0 . 7 5 - - 2x 1 0 4 5 , 9 5 4 4 . 6 E X V - 2 7 2 1 2 9 0 0 0 . 7 5 1 2 (E ) - E X V - 2 7 2 A 78 5 3 2 5 0 . 7 5 1 0 - - - - - - 1 1 0 N E G . N O (E ) - E X V - 2 7 2 B 78 5 3 2 5 0 . 7 5 1 0 USE THIS SCHEUDLE FOR FOR BASE BID ONLY RM . T O T A L 16 6 5 3 6 0 9 0 0 15 7 0 6 5 0 10 27 2 B I O - C H E M I S T R Y 1 7 5 2 0 1 6 5 0 3 0 0 M A V - 2 7 2 1 6 6 5 6 8 0 9 0 0 0 . 7 5 - - 2x 1 0 4 5 , 9 5 4 4 . 6 E X V - 2 7 2 1 2 9 0 3 2 0 0 . 7 5 1 2 (E ) - E X V - 2 7 2 A 78 5 3 2 5 0 . 7 5 1 0 6 " D I A . E X V - 2 7 2 A 1 6 0 0 - - 1 1 0 N E G . N O U S E T H I S SCHEDULE FOR (E ) - E X V - 2 7 2 B 78 5 3 2 5 0 . 7 5 1 0 6 " D I A . E X V - 2 7 2 B 1 6 0 BASE BID WITH ADD ALTERNATE #2 RM . T O T A L 16 6 5 6 8 0 9 0 0 15 7 0 6 5 0 320 10 PR O V I D E T H E S I N G L E P H O E N I X V A L V E S W I T H S Q U A R E F L A N G ED O U T L E T S A N D U N F L A N G E D I N L E T S . CO I L S B A S E D O N 1 9 0 D E G . E N T E R I N G W A T E R T E M P E R A T U R E WIT H 4 0 % G L Y C O L . A N D 5 5 D E G . E N T E R I N G A I R T E M P E R A T UR E . IN L I N E E X H A U S T F A N SY M B O L MA X I M U M A I R F L O W CF M TO T A L S T A T I C PR E S S U R E I N . W . C . BH P ( W ) FA N R P M EL E C T R I C A L DR I V E T Y P E C O O K M O D E L MAX WEIGHT (LBS)MAXIMUM SOUND LEVELS dB (OCTAVE BAND)REMARKS VO L T S P H A S E H E R T Z M O T O R H P 1 2 3 4 5 6 7 8 L W A d B A IE F - 1 5 0 0 0 . 8 1 2 7 1 7 6 5 1 1 5 1 6 0 1 / 3 D I R E C T G N V F - 7 0 0 4 0 6 7 6 8 6 7 6 2 5 8 5 5 5 2 4 9 6 5 5 3 1 , 2 , 3 NO T E S : 1. W I T H L O W L E A K A G E D A M P E R , R U S K I N C D - 5 0 O R B E T T E R , M A X L E A K A G E 3 C F M / F T 2 A T 1 " W . C . W I R E D A M P E R T O O P EN W H E N F A N R U N S . 2. W I T H E C M O T O R SY M B O L L E G E N D CI R C U I T B A L A N C E V A L V E S (E ) CH W S CH W R HW R HW S FS RD FD DTSS. F . D . A. D . H. D . RI S E 24 " x 1 2 " 24 " x 1 8 " SE E S P E C I F I C A T I O N S E C T I O N 2 3 0 5 2 3 16 - 2 5 10 - 1 5 6 - 9 1. 5 - 2 . 5 3 - 5 1. 5 - 2 . 5 GP M RA N G E .5 - 1 . 4 26 - 4 5 CO N N E C T I O N 5 5 55 5555 PR E S S U R E DR O P AV E R A G E IN F T 1/2 AS O 5 0 L AS 1 0 0 AS 1 5 0 AS 1 2 5 AS 2 0 0 AS O 7 5 L AS O 5 O H AS O 7 5 H 1 1- 1 / 4 1- 1 / 2 23/4 3/41/2 FL O W S E T SIZ E SIZ E ( I N ) ------- RE M A R K S - HO T W A T E R S U P P L Y CO L D W A T E R CH I L L E D W A T E R R E T U R N CH I L L E D W A T E R S U P P L Y HO T W A T E R R E T U R N SO I L O R W A S T E DO M E S T I C H O T W A T E R EX I S T I N G DO M E S T I C H O T W A T E R R E C I R C U L A T I N G VE N T CO N C E N T R I C R E D U C E R TH E R M O M E T E R GA U G E W I T H G A U G E C O C K GA U G E C O C K EC C E N T R I C R E D U C E R TH E R M O M E T E R O R G A U G E W E L L SA F E T Y O R R E L I E F V A L V E SO L E N O I D V A L V E GL O B E V A L V E PI P E G U I D E PI P E A N C H O R BL I N D F L A N G E PR E S S U R E / T E M P E R A T U R E T E S T P L U G ( P E T E ' S P L U G ) FL O W C O N T R O L L E R O R B A L A N C E V A L V E FL O O R D R A I N , F L O O R S I N K O R R O O F D R A I N PR E S S U R E R E D U C I N G V A L V E - ( P R V ) ST E A M T R A P DIR T L E G DR A I N ST R A I N E R CH E C K V A L V E BU T T E R F L Y V A L V E PL U G V A L V E CA P EX H A U S T G R I L L E OP P O S E D B L A D E D A M P E R PA R A L L E L B L A D E D A M P E R BR A N C H D U C T T A K E - O F F SP I N - I N F I T T I N G TH E R M O S T A T TE M P E R A T U R E S E N S O R DR O P I N P I P E VA L V E I N R I S E BA L L V A L V E GA T E V A L V E 2 W A Y C O N T R O L V A L V E 3 W A Y C O N T R O L V A L V E CO N T R O L V A L V E ( P L A N V I E W ) RIS E I N P I P E UN I O N NE W C O N N E C T I O N FL A T O V A L ( C R O S S S E C T I O N ) RO U N D D U C T ( C R O S S S E C T I O N ) SU P P L Y D U C T ( C R O S S S E C T I O N ) HA N D D A M P E R SU P P L Y A I R D I R E C T I O N TU R N I N G V A N E S I N D U C T AC C E S S D O O R F O R F I R E D A M P E R AC C O U S T I C A L L I N I N G I N D U C T DR O P O R R I S E I N S U P P L Y D U C T SU P P L Y D I F F U S E R CO M B I N A T I O N S M O K E / F I R E D A M P E R RI S E O R D R O P I N R O U N D O V A L D U C T IN S I D E C L E A R D I M E N S I O N I N I N C H E S DU C T S I Z E , I N S I D E C L E A R D I M E N S I O N I N I N C H E S RE T U R N A I R O R E X H A U S T D U C T ( C R O S S S E C T I O N ) RE T U R N A I R O R E X H A U S T D I R E C T I O N RE T U R N A I R G R I L L E DU C T R I S E DE S C R I P T I O N SY M B O L SE E S P E C I F I C A T I O N S E C T I O N 2 3 3 6 1 6 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????M-001MechanicalSchedulesand Symbol Legend22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid Set D M (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 6 " x 1 2 " (E ) 1 4 " x 1 0 " (E ) 8 " Ø (E ) 8 " Ø (E ) 1 2 " Ø (E ) 1 4 " Ø (E ) 2 4 " Ø ( E ) 2 1 " Ø (E ) 1 0 " Ø (E ) 1 4 " Ø (E ) 8 " Ø (E ) 1 6 " x 1 2 " ( E ) 1 9 " Ø (E ) 1 9 " Ø (E ) 1 0 " Ø (E ) 1 2 " x 1 2 " (E ) 1 0 " Ø ( E ) 1 2 " Ø ( E ) 1 2 " x 1 2 " (E ) 1 0 " Ø (E ) 1 9 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 6 " x 1 2 " (E ) 1 6 " x 1 2 " (E ) 1 4 " x 1 4 " (E ) 1 2 " Ø (E ) 2 0 " x 1 0 " (E ) 8 " x 6 " (E ) 1 4 " x 1 4 " (E ) 2 0 " x 1 0 " (E ) 1 2 " x 1 2 " (E ) 8 " x 1 0 " (E ) 1 2 " x 1 2 " (E ) 1 4 " x 1 2 " (E ) 1 6 " x 1 2 "(E)14"Ø(E ) 1 6 " x 1 2 " (E ) 2 0 " x 1 0 " (E ) 1 4 " x 1 2 " (E ) 1 0 " x 6 " (E ) 3 0 " x 3 0 " (E ) E X H A U S T R I S E R (E ) 1 0 " x 1 2 " (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " x 6 " (E ) 8 " x 6 " (E ) 8 " x 6 " (E ) 8 " x 6 " (E ) 8 " x 6 " (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " x 6 " (E ) 8 " x 6 " (E ) 8 " Ø (E ) 1 2 " Ø (E ) 8 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " x 1 2 " (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 8 " Ø (E ) 2 0 " x 1 0 " (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) E X H A U S T R I S E R (E ) 1 0 " x 6 " (E ) 1 0 " x 1 0 " (E ) 1 0 " x 6 " (E ) 1 4 " x 1 0 " ( E ) 1 4 " x 8 " (E ) 8 " x 4 " ( E ) 8 " x 4 " (E ) C A B I N E T H E A T E R (E ) C A B I N E T H E A T E R T T T T T T T T T T T T T T T T A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 6 66 6 5 55 5 6 66 6 5 55 555555555 5 55 5 5 55 5 5 55 5 5 55 5 5 55 5 5 55 5 5 55 5 5 55 5 1 11 111111111 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 2 22 2 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 2 22 2 3 33 3 3 33 33333 3 33 3 3 33 3 3 33 3 2 22 2 3 33 3 3 33 3 2 22 2 3 33 3 3 33 3 3 33 3 3 33 3 3 33 33333 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 2 22 2 2 22 2 2 22 2 3 33 3 3 33 3 3 33 3 7 77 7 8 88 8 8 88 8 dbkbo^i=klqbp A.A.A.A.FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PERIOD. PERIOD. PERIOD. PERIOD. PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR PATCHWORK. PATCHWORK. PATCHWORK. PATCHWORK. INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING UNITS. UNITS. UNITS. UNITS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING COMPONENTS. COMPONENTS. COMPONENTS. COMPONENTS. EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND TERMINATED.TERMINATED.TERMINATED.TERMINATED.B.B.B.B.C.C.C.C.D.D.D.D.E.E.E.E.F.F.F.F.G.G.G.G.H.H.H.H.I.I.I.I.J.J.J.J.K.K.K.K.L.L.L.L.M.M.M.M.N.N.N.N.3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MD100Level 00 Mechanical Demolition Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES NOTE # DESCRIPTION 1 11 1 REMOVE EXISTING VAV BOX AND BRANCH REMOVE EXISTING VAV BOX AND BRANCH REMOVE EXISTING VAV BOX AND BRANCH REMOVE EXISTING VAV BOX AND BRANCH DUCTWORK COMPLETE.DUCTWORK COMPLETE.DUCTWORK COMPLETE.DUCTWORK COMPLETE.2 22 2 REMOVE EXISTING EXHAUST DUCTWORK AS REMOVE EXISTING EXHAUST DUCTWORK AS REMOVE EXISTING EXHAUST DUCTWORK AS REMOVE EXISTING EXHAUST DUCTWORK AS SHOWN.SHOWN.SHOWN.SHOWN.3 33 3 R E M O V E E X I S T I N G G R I L L E S A N D D I F F U S E R S A S REMOVE EXISTING GRILLES AND DIFFUSERS AS REMOVE EXISTING GRILLES AND DIFFUSERS AS REMOVE EXISTING GRILLES AND DIFFUSERS AS SHOWN.SHOWN.SHOWN.SHOWN.4 44 4 R E M O V E S E C T I O N O F E X I S T I N G M A I N D U C T W O R K REMOVE SECTION OF EXISTING MAIN DUCTWORK REMOVE SECTION OF EXISTING MAIN DUCTWORK REMOVE SECTION OF EXISTING MAIN DUCTWORK AS SHOWN.AS SHOWN.AS SHOWN.AS SHOWN.5 55 5 R E M O V E E X I S T I N G T E M P E R A T U R E S E N S O R REMOVE EXISTING TEMPERATURE SENSOR REMOVE EXISTING TEMPERATURE SENSOR REMOVE EXISTING TEMPERATURE SENSOR COMPLETE.COMPLETE.COMPLETE.COMPLETE.6 66 6 R E M O V E E X I S T I N G C A B I N E T H E A T E R S C O M P L E T E . REMOVE EXISTING CABINET HEATERS COMPLETE.REMOVE EXISTING CABINET HEATERS COMPLETE.REMOVE EXISTING CABINET HEATERS COMPLETE.7 77 7 R E M O V E E X I S T I N G D U C T T H R O U G H W A L L A N D REMOVE EXISTING DUCT THROUGH WALL AND REMOVE EXISTING DUCT THROUGH WALL AND REMOVE EXISTING DUCT THROUGH WALL AND ABANDON. WALL OPENING SHALL BE INSULATED ABANDON. WALL OPENING SHALL BE INSULATED ABANDON. WALL OPENING SHALL BE INSULATED ABANDON. WALL OPENING SHALL BE INSULATED AND SEALED.AND SEALED.AND SEALED.AND SEALED.8 88 8 E X I S T I N G C A B I N E T H E A T E R S T O R E M A I N . EXISTING CABINET HEATERS TO REMAIN.EXISTING CABINET HEATERS TO REMAIN.EXISTING CABINET HEATERS TO REMAIN. SC A L E : SC A L E : SC A L E : SC A L E : MD 1 0 0 MD 1 0 0 MD 1 0 0 MD 1 0 0 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 0 M E C H A N I C A L D E M O L I T I O N P L A N 1 11 1 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 S S S S T T S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S ( E ) 1 6 " X 1 0 " ( E ) 1 4 " X 1 0 " (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 6 " x 1 4 " (E ) 1 2 " Ø (E ) 1 4 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø ( E ) 1 8 " x 1 4 " (E ) 1 4 " Ø (E ) 8 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 4 " x 1 4 " (E ) 1 0 " x 1 2 " (E ) 1 0 " x 4 " ( E ) 2 2 " x 2 2 " (E ) 1 0 " x 8 " (E ) 1 0 " x 1 0 " ( E ) 3 3 " Ø (E ) 3 3 " Ø ( E ) 3 2 " Ø ( E ) 1 2 " Ø ( E ) 1 2 " Ø (E ) 1 8 " x 1 4 " (E ) 1 4 " Ø (E ) 1 4 " Ø ( E ) 1 2 " x 1 2 " (E ) 1 4 " x 1 0 " (E ) 2 7 " Ø (E ) 2 4 " Ø (E ) 2 1 " Ø (E ) 2 0 " Ø (E ) 1 8 " Ø (E ) 1 6 " Ø (E ) 1 8 " Ø (E ) 1 5 " Ø (E ) 1 4 " Ø (E ) 1 2 " x 1 0 " (E ) 1 0 " x 1 2 " ( E ) 1 2 " Ø ( E ) 1 2 " Ø ( E ) 1 2 " Ø ( E ) 1 8 " x 1 4 " ( E ) 1 8 " x 1 4 " (E ) 1 4 " x 1 2 " (E ) 1 2 " x 1 2 " (E ) F . D (E ) 6 0 " x 2 4 " R A (E ) F . D (E ) F . D (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø ( E ) 1 0 " Ø (E ) 1 0 " x 8 " (E ) 1 0 " x 1 2 " (E ) 1 2 " Ø ( E ) 1 2 " Ø (E ) 1 2 " Ø ( E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø ( E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø ( E ) 1 0 " Ø ( E ) 1 6 " X 1 0 " ( E ) 1 6 " X 1 0 " ( E ) 1 8 " x 1 4 " ( E ) 1 8 " x 1 4 " (E ) 1 2 " Ø (E ) 1 0 " Ø ( E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 2 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 1 4 " x 1 2 " (E ) 1 4 " x 1 2 " (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø ( E ) 2 8 " x 1 6 " F . O . C O L D (E ) 1 8 " x 1 4 " F . O . H O T (E ) 1 6 " ∅ C O L D ( E ) 1 6 " x 1 0 " E X H . (E ) 1 4 " x 8 " E X H . (E ) 1 6 " x 5 " (E ) 1 6 " x 1 8 " EX H . U P (E ) A L A R M (E ) T . I . (E ) 1 0 " x 1 0 " + 1 " A L (E ) 2 6 " x 1 4 " E X H . ( E ) 2 6 " x 1 6 " E X H . (E ) 1 8 " x 1 8 " (E ) 3 8 " x 2 2 " F . O . C O L D (E ) 2 0 " x 1 6 " (E ) 1 6 " ∅ C O L D ( E ) 8 " ∅ (E ) 2 6 " x 1 4 " E X H . (E ) 1 0 " x 1 2 " + 1 " A L ( E ) 1 0 " ∅ (E ) 1 0 " x 1 0 " +1 " A L ( E ) 6 " ∅ ( E ) 8 " ∅ (E ) 2 2 " x 1 4 " + 1 " A L (E ) 1 6 " x 1 0 " (E ) 1 8 " x 1 2 " (E ) 2 6 " x 1 4 " E X H . 10 " x 8 " (E ) 1 8 " x 1 4 " + 1 " A L ( E ) 1 2 " ∅ (E ) 1 4 " x 1 0 " + 1 " A L (E ) 1 6 " x 1 2 " + 1 " A L (E ) 1 6 " x 1 2 " + 1 " A L (E ) 1 4 " x 1 0 " + 1 " A L ( E ) 2 6 " x 1 4 " E X H . (E ) 8 " x 1 0 " + 1 " A L (E ) 1 0 " x 1 2 " + 1 " A L (E ) 2 0 " x 1 2 " ( E ) 1 2 " ∅ (E ) 1 2 " x 1 2 " +1 " A L (E ) 8 " x 8 " + 1 " A L (E ) 1 0 " x 8 " + 1 " A L ( E ) 1 0 " ∅ (E ) 1 2 " x 8 " ( E ) 1 0 " x 8 " (E ) 8 " x 8 " + 1 " A L ( E ) 8 " ∅ ( E ) 1 0 " x 6 " (E ) 1 4 " x 1 0 " (E ) 2 2 " x 1 4 " F . O . C O L D (E ) 1 8 " x 1 4 " (E ) 1 8 " x 1 4 " F . O . H O T (E ) 3 0 " ∅ C O L D ( E ) 3 8 " x 1 6 " F . O . C O L D (E ) 3 8 " x 1 6 " F . O . C O L D (E ) 2 2 " x 1 4 " + 1 " A L (E ) 3 0 " x 1 6 " + 1 " A L (E ) 2 2 " ∅ H O T ( E ) 4 0 " x 1 8 " E X H . ( E ) 3 0 " x 1 6 " (E ) 3 0 " x 1 6 " + 1 " A L (E ) 3 6 " x 1 2 " (E ) 3 6 " x 1 2 " (E ) 3 0 " x 1 6 " + 1 " A L 2 2 " x 1 6 " (E ) 2 2 " x 1 6 " F . O . H O T (E ) 1 4 " x 1 0 " +1 " A L (E ) 1 8 " x 1 4 " F . O . ( E ) 8 " ∅ ( E ) 8 " ∅ (E ) 1 6 " x 1 4 " (E ) 1 4 " x 1 2 " F . O . ( E ) 1 4 " ∅ ( E ) 6 " ∅ (E ) 3 0 " x 1 6 " + 1 " A L (E ) 3 0 " x 1 6 " + 1 " A L ( E ) 2 6 " x 1 6 " F . O . C O L D (E ) 3 6 " x 1 8 " F . O C O L D (E ) 1 0 " x 8 " ( E ) 6 " ∅ (E ) 2 2 " x 1 4 " F . O . H O T HR R HR S HW R HW S (E ) 2 8 " ∅ CO L D HR S HW S HR R HW R HR R HR S HW S HW R H R R H W R H R S H W S H W R H W S H R R H R S (E ) 3 / 4 " (E ) 2 " (E ) 2 4 " x 1 4 " CO L D H R R H R S H W R H W S (E ) 1 - 1 / 4 " (E ) 1 0 " x 8 " +1 " A L (E ) 8 " x 8 " +1 " A L ( E ) 8 " ∅ (E ) 3 " (E ) 2 4 " ∅ ( E ) 1 2 " ∅ (E ) 1 0 " x 1 0 " + 1 " A L (E ) 8 " x 8 " +1 " A L (E ) 8 " x 8 " +1 " A L (E ) 1 0 " x 8 " +1 " A L ( E ) 8 " ∅ ( E ) 8 " ∅ ( E ) 6 " ∅ ( E ) 1 2 " ∅ (E ) 2 0 " x 1 0 " (E ) 2 6 " x 1 2 " (E ) 2 6 " x 1 2 " (E ) 2 6 " x 1 2 " (E ) 2 6 " x 1 4 " (E ) 4 2 " x 1 2 " (E ) 2 6 " x 1 2 " (E ) 2 0 " ∅ (E ) 1 0 " Ø (E ) 1 2 " Ø ( E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø ( E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø ( E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø ( E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 6 " Ø (E ) 6 " Ø (E ) 6 " Ø (E ) 6 " Ø (E ) 6 " Ø ( E ) 6 " Ø ( E ) 8 " ∅ (E ) 6 " Ø (E ) 6 " Ø (E ) 6 " Ø (E ) 6 " Ø (E ) 6 " Ø (E ) 8 " Ø ( E ) 8 " ∅ (E ) 8 " Ø (E ) 6 " Ø (E ) 1 2 " Ø (E ) 8 " Ø (E ) 8 " Ø (E ) 1 4 " Ø (E ) 6 " Ø (E ) 6 " Ø ( E ) 8 " ∅ (E ) 1 - 1 / 4 " (E ) 1 - 1 / 4 " (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 - 1 / 2 " (E ) 8 " x 8 " +1 " A L (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " Ø (E ) 1 0 " x 1 0 " +1 " A L (E ) 1 0 " x 1 0 " +1 " A L (E ) 1 0 " x 1 0 " +1 " A L (E ) 1 0 " x 1 0 " +1 " A L (E ) 1 2 " x 1 2 " +1 " A L (E ) 1 4 " Ø (E ) 1 0 " Ø (E ) 1 4 " Ø (E ) 1 4 " Ø (E ) 1 6 " ∅ C O L D (E ) 8 " Ø (E ) 1 - 1 / 4 " (E ) 1 - 1 / 4 " (E ) 1 0 " Ø (E ) 8 " x 8 " +1 " A L (E ) 2 " (E ) 3 " (E ) 1 - 1 / 2 " (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 8 " Ø (E ) 6 " Ø (E ) 1 0 " x 1 0 " +1 " A L (E ) 1 2 " Ø (E ) 3 / 4 " (E ) 3 / 4 " (E ) 2 " (E ) 2 " (E ) 3 " (E ) 1 0 " Ø (E ) 8 " x 1 0 " + 1 " A L (E ) 2 8 " ∅ CO L D (E ) 3 " (E ) 1 2 " Ø (E ) 1 2 " Ø (E ) 3 / 4 " (E ) 4 " (E ) 1 6 " x 1 0 " (E ) 1 0 " x 1 2 " + 1 " A L (E ) 1 4 " Ø H O T (E ) 1 0 " Ø (E ) 1 " (E ) 1 " (E ) 1 2 " Ø (E ) 1 - 1 / 4 " (E ) 1 - 1 / 2 " (E ) 1 4 " Ø (E ) 3 / 4 " A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 1 11 1 2 22 2 2 22 2 1 11 1 1 11 11111 1 11 1 1 11 1 1 11 11111 1 11 11111 1 11 1 1 11 1 3 33 3 4 44 4 4 44 4 dbkbo^i=klqbp A.A.A.A. F I E L D V E R I F Y E X A C T L O C A T I O N S O F E X I S T I N G FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PERIOD. PERIOD. PERIOD. PERIOD. PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR PATCHWORK. PATCHWORK. PATCHWORK. PATCHWORK. INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING UNITS. UNITS. UNITS. UNITS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING COMPONENTS. COMPONENTS. COMPONENTS. COMPONENTS. EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND TERMINATED.TERMINATED.TERMINATED.TERMINATED.B.B.B.B.C.C.C.C.D.D.D.D.E.E.E.E.F.F.F.F.G.G.G.G.H.H.H.H.I.I.I.I.J.J.J.J.K.K.K.K.L.L.L.L.M.M.M.M.N.N.N.N.3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MD102Level 02 Mechanical Demolition Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE # DESCRIPTION 1 11 1 REMOVE DIFFUSERS AND GRILLES WITH BRANCH REMOVE DIFFUSERS AND GRILLES WITH BRANCH REMOVE DIFFUSERS AND GRILLES WITH BRANCH REMOVE DIFFUSERS AND GRILLES WITH BRANCH DUCTWORK.DUCTWORK.DUCTWORK.DUCTWORK.2 22 2 REMOVE EXISTING VAVR BOX W/ CONTROLS REMOVE EXISTING VAVR BOX W/ CONTROLS REMOVE EXISTING VAVR BOX W/ CONTROLS REMOVE EXISTING VAVR BOX W/ CONTROLS COMPLETE.COMPLETE.COMPLETE.COMPLETE.3 33 3 R E M O V E E X I S T I N G T E M P E R A T U R E S E N S O R REMOVE EXISTING TEMPERATURE SENSOR REMOVE EXISTING TEMPERATURE SENSOR REMOVE EXISTING TEMPERATURE SENSOR COMPLETE.COMPLETE.COMPLETE.COMPLETE.4 44 4 R E F E R E N C E P L U M B I N G D R A W I N G S F O R W O R K I N REFERENCE PLUMBING DRAWINGS FOR WORK IN REFERENCE PLUMBING DRAWINGS FOR WORK IN REFERENCE PLUMBING DRAWINGS FOR WORK IN THIS AREA.THIS AREA.THIS AREA.THIS AREA. SC A L E : SC A L E : SC A L E : SC A L E : MD 1 0 2 MD 1 0 2 MD 1 0 2 MD 1 0 2 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 2 M E C H A N I C A L D E M O L I T I O N P L A N 1 11 1 CA P CA P (E ) 3 " H W R (E ) 3 " H W S (E ) 1 - 1 / 2 " HW R / S (E ) 2 " H W R / S (E ) 3 / 4 " H W S (E ) 3 / 4 " H W S (E ) 3 / 4 " H W R / S (E ) C A B I N E T H E A T E R (E ) C A B I N E T H E A T E R (E ) 1 - 1 / 2 " H W R / S (E ) 1 - 1 / 4 " H W R / S (E ) 1 - 1 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 3 " H W R / S (E ) C A B I N E T H E A T E R (E ) 3 / 4 " HW R / S (E ) 1 " HW R / S dbkbo^i=klqbp A.A.A.A. F I E L D V E R I F Y E X A C T L O C A T I O N S O F E X I S T I N G FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PERIOD. PERIOD. PERIOD. PERIOD. PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR PATCHWORK. PATCHWORK. PATCHWORK. PATCHWORK. INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING UNITS. UNITS. UNITS. UNITS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING COMPONENTS. COMPONENTS. COMPONENTS. COMPONENTS. EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND TERMINATED.TERMINATED.TERMINATED.TERMINATED.B.B.B.B.C.C.C.C.D.D.D.D.E.E.E.E.F.F.F.F.G.G.G.G.H.H.H.H.I.I.I.I.J.J.J.J.K.K.K.K.L.L.L.L.M.M.M.M.N.N.N.N.A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 2 22 2 3 33 33333 3 33 3 3 33 3 1 11 1 1 11 1 1 11 1 1 11 1 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MD200Level 00 Mechanical Piping Demolition Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE # DESCRIPTION 1 11 1 SHUTOFF HEATING WATER SYSTEM, DRAIN AND SHUTOFF HEATING WATER SYSTEM, DRAIN AND SHUTOFF HEATING WATER SYSTEM, DRAIN AND SHUTOFF HEATING WATER SYSTEM, DRAIN AND SAVE GLYCOL FOR REUSE. REMOVE A SECTION SAVE GLYCOL FOR REUSE. REMOVE A SECTION SAVE GLYCOL FOR REUSE. REMOVE A SECTION SAVE GLYCOL FOR REUSE. REMOVE A SECTION OF HWS AND HWR PIPING INCLUDING ISOLATION OF HWS AND HWR PIPING INCLUDING ISOLATION OF HWS AND HWR PIPING INCLUDING ISOLATION OF HWS AND HWR PIPING INCLUDING ISOLATION VALVES, BALANCE VALVE STRAINER, CONTROL VALVES, BALANCE VALVE STRAINER, CONTROL VALVES, BALANCE VALVE STRAINER, CONTROL VALVES, BALANCE VALVE STRAINER, CONTROL VALVE, ETC. SERVING VAV FAN POWERED BOX VALVE, ETC. SERVING VAV FAN POWERED BOX VALVE, ETC. SERVING VAV FAN POWERED BOX VALVE, ETC. SERVING VAV FAN POWERED BOX OR REHEAT BOX. CAP AT MAIN UNLESS PIPING IS OR REHEAT BOX. CAP AT MAIN UNLESS PIPING IS OR REHEAT BOX. CAP AT MAIN UNLESS PIPING IS OR REHEAT BOX. CAP AT MAIN UNLESS PIPING IS GOING TO BE RECONNECTED TO A NEW VAV GOING TO BE RECONNECTED TO A NEW VAV GOING TO BE RECONNECTED TO A NEW VAV GOING TO BE RECONNECTED TO A NEW VAV REHEAT BOX. SEE REMODEL PLAN.REHEAT BOX. SEE REMODEL PLAN.REHEAT BOX. SEE REMODEL PLAN.REHEAT BOX. SEE REMODEL PLAN.2 22 2 W I T H S Y S T E M D R A I N E D A N D I S O L A T E D , R E M O V E WITH SYSTEM DRAINED AND ISOLATED, REMOVE WITH SYSTEM DRAINED AND ISOLATED, REMOVE WITH SYSTEM DRAINED AND ISOLATED, REMOVE THE EXISTING PNEUMATICCONTROL VALVE.THE EXISTING PNEUMATICCONTROL VALVE.THE EXISTING PNEUMATICCONTROL VALVE.THE EXISTING PNEUMATICCONTROL VALVE.3 33 3 R E M O V E E X I S T I N G F A N P O W E R E D V A V B O X . S E E REMOVE EXISTING FAN POWERED VAV BOX. SEE REMOVE EXISTING FAN POWERED VAV BOX. SEE REMOVE EXISTING FAN POWERED VAV BOX. SEE DRAWING MD100.DRAWING MD100.DRAWING MD100.DRAWING MD100.4 44 4 R E M O V E E X I S T I N G V A V R E H E A T B O X . REMOVE EXISTING VAV REHEAT BOX.REMOVE EXISTING VAV REHEAT BOX.REMOVE EXISTING VAV REHEAT BOX.5 55 5 S H U T O F F H E A T I N G W A T E R S Y S T E M , D R A I N A N D SHUTOFF HEATING WATER SYSTEM, DRAIN AND SHUTOFF HEATING WATER SYSTEM, DRAIN AND SHUTOFF HEATING WATER SYSTEM, DRAIN AND SAVE GLYCOL FOR REUSE. REMOVE THE EXISTING SAVE GLYCOL FOR REUSE. REMOVE THE EXISTING SAVE GLYCOL FOR REUSE. REMOVE THE EXISTING SAVE GLYCOL FOR REUSE. REMOVE THE EXISTING 1" AND 2" ISOLATION VALVES. REPLACE WITH 1" AND 2" ISOLATION VALVES. REPLACE WITH 1" AND 2" ISOLATION VALVES. REPLACE WITH 1" AND 2" ISOLATION VALVES. REPLACE WITH NEW BALL VALVES.NEW BALL VALVES.NEW BALL VALVES.NEW BALL VALVES. SC A L E : SC A L E : SC A L E : SC A L E : MD 2 0 0 MD 2 0 0 MD 2 0 0 MD 2 0 0 1/8 " = 1 ' 1/8 " = 1 ' 1/8 " = 1 ' 1/8 " = 1 ' ----0"0"0"0" LE V E L 0 0 M E C H A N I C A L P I P I N G D E M O L I T I O N P L A N 1 11 1 CA P HR R HR S HW R HW S HR S HW S HR R HW R HR R HR S HW S HW R H R R H W R H R S H W S H W R H W S H R R H R S (E ) 3 / 4 " (E ) 2 " H R R H R S H W R H W S (E ) 1 - 1 / 4 " (E ) 3 " (E ) 1 - 1 / 4 " (E ) 1 - 1 / 4 " (E ) 1 - 1 / 2 " (E ) 1 - 1 / 4 " (E ) 1 - 1 / 4 " (E ) 2 " (E ) 3 " (E ) 1 - 1 / 2 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 2 " (E ) 2 " (E ) 3 " (E ) 3 " (E ) 3 / 4 " (E ) 4 " (E ) 1 " (E ) 1 " (E ) 1 - 1 / 4 " (E ) 1 - 1 / 2 " (E ) 3 / 4 " (E ) 1 - 1 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 2 " H W R / S (E ) 1 - 1 / 4 " HW R / S (E ) 1 " H W R / S (E ) 3 / 4 " HW R / S (E ) 3 / 4 " H W R / S (E ) 2 - 1 / 2 " H W R / S (E ) 3 / 4 " HW R / S (E ) 3 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 2 " H W R / S ( E ) 2 " H W R / S (E ) 2 " H W R / S (E ) 1 - 1 / 2 " H W R / S (E ) 1 - 1 / 2 " HW R / S (E ) 1 - 1 / 4 " HW R / S (E ) 1 - 1 / 4 " HW R / S (E ) 1 - 1 / 4 " HW R / S (E ) 1 - 1 / 4 " HW R / S (E ) 1 " H W R / S (E ) 3 / 4 " HW R / S (E ) 3 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) 3 / 4 " H W R / S (E ) V A V R - 2 7 1 (E ) V A V R - 2 7 2 (E ) V A V R - 2 6 8 (E ) V A V R - 2 7 0 (E ) V A V R - 2 6 2 (E ) V A V R - 2 6 0 (E ) V A V R - 2 5 5 B (E ) V A V R - 2 3 9 (E ) V A V R - 2 3 8 (E ) V A V R - 2 3 4 (E ) V A V R - 2 3 0 (E ) V A V R - 2 4 3 (E ) V A V R - 2 5 2 (E ) V A V R - 2 7 6 (E ) V A V R - 2 5 5 A (E ) 1 - 1 / 2 " HW R / S dbkbo^i=klqbp A.A.A.A. F I E L D V E R I F Y E X A C T L O C A T I O N S O F E X I S T I N G FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING FIELD VERIFY EXACT LOCATIONS OF EXISTING PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. PIPING, DUCTWORK, EQUIPMENT, ETC. DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED DEMOLITION FLOOR PLANS HAVE BEEN CREATED USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. USING AVAILABLE RECORD DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, VERIFYING EXACT ROUTING OF ALL PIPING, DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DUCTWORK, ETC. DURING CONSTRUCTION. DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND DEMOLITION OF EXISTING MECHANICAL AND PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE PLUMBING CONSTRUCTION SHALL BE TO THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE EXTENT REQUIRED TO ACCOMMODATE THE RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. RENOVATION AND THE ADDITION OF NEW WORK. REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION REFERENCE ARCHITECTURAL DEMOLITION DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE DRAWINGS TO COORDINATE AND VERIFY THE EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. EXTENT OF THE DEMOLITION WORK REQUIRED. ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE ALL PIPING, DUCTWORK, ETC. TO REMAIN SHALL BE PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PROTECTED THROUGHOUT THE CONSTRUCTION PERIOD. PERIOD. PERIOD. PERIOD. PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN PROVIDE AND INSTALL CAPS ON EXISTING MAIN DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING DUCTWORK AND / OR PIPING BRANCH BEING REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR REMOVED. REFERENCE ARCHITECTURAL FOR PATCHWORK. PATCHWORK. PATCHWORK. PATCHWORK. INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INDICATED DEMOLITION OF PIPING AND DUCTWORK INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, OF DUCTWORK, PIPING, FITTINGS, VALVES, HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS HANGERS, SUPPORTS, INSULATION, ETC. UNLESS NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. NOTED OTHERWISE. INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL INDICATED DEMOLITION OF MECHANICAL EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, EQUIPMENT INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, THE REMOVAL OF EQUIPMENT, PIPING, VALVES, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, INSULATION, SEISMIC BRACING, CONTROLS, ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. ELECTRICAL, ETC. UNLESS NOTED OTHERWISE. FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF FIELD VERIFY EXACT LOCATIONS OF THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING THERMOSTATS, SENSOR AND CONTROLLING UNITS. UNITS. UNITS. UNITS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED PATCHING AND REPAIRING ANY DAMAGE CAUSED BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO BY HIS / HER PERSONNEL TO EXISTING THAT IS TO REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING REMAIN OR TO NEWLY INSTALLED BUILDING COMPONENTS. COMPONENTS. COMPONENTS. COMPONENTS. EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN EXISTING PIPING INSULATION MAY CONTAIN ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE ASBESTOS. THE OWNER IS RESPONSIBLE FOR THE REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT REMOVAL AND HANDLING OF ANY SUSPECT MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE MATERIALS. IF DURING THE COARSE OF THE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE WORK ANY SUSPECT MATERIALS ARE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE ENCOUNTERED BY THE CONTRACTOR, THE CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN CONTRACTOR IS TO IMMEDIATELY STOP WORK IN THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.THE AREA AND NOTIFY THE OWNER.PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS PATCH AND SEAL ALL ABANDONED OPENINGS THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING THROUGH WALLS AND FLOORS. MATCH EXISTING SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. SURROUNDING FINISH. CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION CONTRACTOR SHALL REPLACE ANY INSULATION THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON THAT IS DAMAGED DURING CONSTRUCTION ON PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PIPE OR DUCTWORK THAT IS TO REMAIN. PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK PRIOR TO DEMOLITION OF ANY EQUIPMENT WORK WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS WITH ELECTRICAL CONTRACTOR AND CONTROLS CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTRACTOR TO MAKE CERTAIN POWER AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND CONTROLS ARE PROPERLY DISCONNECTED AND TERMINATED.TERMINATED.TERMINATED.TERMINATED.B.B.B.B.C.C.C.C.D.D.D.D.E.E.E.E.F.F.F.F.G.G.G.G.H.H.H.H.I.I.I.I.J.J.J.J.K.K.K.K.L.L.L.L.M.M.M.M.N.N.N.N.A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 1 11 1 2 22 2 2 22 2 1 11 1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MD202Level 02 Mechanical Piping Demolition Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE #DESCRIPTION 1 11 1 SHUTOFF HEATING WATER SYSTEM, DRAIN AND SHUTOFF HEATING WATER SYSTEM, DRAIN AND SHUTOFF HEATING WATER SYSTEM, DRAIN AND SHUTOFF HEATING WATER SYSTEM, DRAIN AND SAVE GLYCOL FOR REUSE. REMOVE A SECTION SAVE GLYCOL FOR REUSE. REMOVE A SECTION SAVE GLYCOL FOR REUSE. REMOVE A SECTION SAVE GLYCOL FOR REUSE. REMOVE A SECTION OF HWS AND HWR PIPING INCLUDING ISOLATION OF HWS AND HWR PIPING INCLUDING ISOLATION OF HWS AND HWR PIPING INCLUDING ISOLATION OF HWS AND HWR PIPING INCLUDING ISOLATION VALVES, BALANCE VALVE STRAINER, CONTROL VALVES, BALANCE VALVE STRAINER, CONTROL VALVES, BALANCE VALVE STRAINER, CONTROL VALVES, BALANCE VALVE STRAINER, CONTROL VALVE, ETC. SERVING VAV FAN POWERED BOX VALVE, ETC. SERVING VAV FAN POWERED BOX VALVE, ETC. SERVING VAV FAN POWERED BOX VALVE, ETC. SERVING VAV FAN POWERED BOX OR REHEAT BOX. CAP AT MAIN UNLESS PIPING IS OR REHEAT BOX. CAP AT MAIN UNLESS PIPING IS OR REHEAT BOX. CAP AT MAIN UNLESS PIPING IS OR REHEAT BOX. CAP AT MAIN UNLESS PIPING IS GOING TO BE RECONNECTED TO A NEW VAV GOING TO BE RECONNECTED TO A NEW VAV GOING TO BE RECONNECTED TO A NEW VAV GOING TO BE RECONNECTED TO A NEW VAV REHEAT BOX. SEE REMODEL PLAN.REHEAT BOX. SEE REMODEL PLAN.REHEAT BOX. SEE REMODEL PLAN.REHEAT BOX. SEE REMODEL PLAN.2 22 2 R E M O V E E X I S T I N G V A V R E H E A T B O X . REMOVE EXISTING VAV REHEAT BOX.REMOVE EXISTING VAV REHEAT BOX.REMOVE EXISTING VAV REHEAT BOX. SC A L E : SC A L E : SC A L E : SC A L E : MD 2 0 2 MD 2 0 2 MD 2 0 2 MD 2 0 2 1/8 " = 1 ' 1/8 " = 1 ' 1/8 " = 1 ' 1/8 " = 1 ' ----0"0"0"0" LE V E L 0 2 M E C H A N I C A L P I P I N G D E M O L I T I O N P L A N 1 11 1 A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 66 ME N ' S R M 64 WO M E N ' S R M O- C HA L L W A Y O- A VE S T I B U L E 69 ME C H A N I C A L R O O M 68 CU S T R M 59 CO M P U T E R L A B 59 D DA R K R O O M 59 E FI L M 59 C VE S T I B U L E 51 PH O T O S T U D I O 59 A EQ U I P / C H E C K O U T 59 B ST O R A G E 57 OF F I C E 55 OF F I C E 50 CL A S S R O O M 0- H VE S T I B U L E 51 B CH A N G I N G 52 C ST O R A G E 52 PH Y S I C S L A B 52 B AC O U S T I C S S T U D I O 52 A OP T I C S L A B 67 O- D EL E V A T O R 18 ST O R A G E 16 CU S T O F F I C E 14 CU S T O D I A L L A U N D R Y R M 12 ME C H R M 0- K EL E V A T O R 10 ME C H A N I C A L R M O- B ST A I R W E L L 63 ST O R A G E 1 11 1 2 22 2 3 33 3 5 55 5 6 66 6 7 77 7 8 88 8 9 99 9 10 1010 10 11 1111 11 12 1212 12 13 1313 13 14 1414 14 36 " x 2 4 " F . O . 36 " x 2 4 " F . O . 36 " x 2 4 " F . O . 36 " x 2 4 " F . O . 16 1616 16 22 " Ø 22 " Ø 22 " Ø 22 " Ø 2 2 " Ø 2 2 " Ø 2 2 " Ø 2 2 " Ø 8" x 8 " E X H . 8" x 8 " E X H . 8" x 8 " E X H . 8" x 8 " E X H . 4 44 4 4 44 4 4 44 4 4 44 4 4 44 4 4 44 4 2 22 2 2 22 2 3 33 3CHCHCHCH 1 11 1CHCHCHCH 2 22 2CHCHCHCH 2 22 2 2 22 2 2 22 2 12 1212 12 12 1212 12 12 1212 12 12 1212 12 12 1212 12 12 1212 12 12 1212 12 5 55 5 2 22 2 2 22 2 13 1313 13 13 1313 13 13 1313 13 13 1313 13 13 1313 13 14 1414 14 14 1414 1414141414 14 1414 1414141414 14 1414 14 14 1414 14 5 55 5 5 55 5 9 99 9 8 88 8 8 88 8 3 33 3 3 33 3 3 33 3 3 33 3 3 33 3 3 33 33333 3 33 3 6 66 6 6 66 6 6 66 6 1 11 1 7 77 7 7 77 7 7 77 7 7 77 7 8 88 8 8" Ø 8" Ø 8 " Ø 8" Ø59 D 59 D 59 D 59 D VA V R VA V R VA V R VA V R 1 0 " x 1 0 " + 1 " A L 1 0 " x 1 0 " + 1 " A L 1 0 " x 1 0 " + 1 " A L 1 0 " x 1 0 " + 1 " A L H. D . H. D . H. D . H. D .8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 14 " Ø 14 " Ø 14 " Ø 14 " Ø 51 5151 51 VA V R VA V R VA V R VA V R 10 " x 8 " + 1 " A L 10 " x 8 " + 1 " A L 10 " x 8 " + 1 " A L 10 " x 8 " + 1 " A L H. D . H. D . H. D . H. D . H . D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 6" Ø 6" Ø 6 " Ø 6" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L 1 4 " x 1 4 " + 1 " A L 1 4 " x 1 4 " + 1 " A L 1 4 " x 1 4 " + 1 " A L 1 4 " x 1 4 " + 1 " A L H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H . D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø8" Ø 8" Ø 8 " Ø 8" Ø 6" Ø 6" Ø 6 " Ø 6" Ø 5 55 5 14 " Ø 14 " Ø 14 " Ø 14 " Ø59595959 VA V R VA V R VA V R VA V R 1 8 " x 1 4 " + 1 " A L 1 8 " x 1 4 " + 1 " A L 1 8 " x 1 4 " + 1 " A L 1 8 " x 1 4 " + 1 " A L 10 " Ø 10 " Ø 10 " Ø 10 " Ø 1 0 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . H . D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . 16 " Ø 16 " Ø 16 " Ø 16 " Ø 0 00 0 ----C CC C VA V R VA V R VA V R VA V R H. D . H. D . H. D . H. D . H . D . H. D . H. D . H. D . H . D . H. D . H. D . H. D . H . D . H. D . H. D . H. D . 20 " x 1 6 " + 1 " A L 20 " x 1 6 " + 1 " A L 20 " x 1 6 " + 1 " A L 20 " x 1 6 " + 1 " A L H. D . H. D . H. D . H. D . 12 " Ø , T Y P . 12 " Ø , T Y P . 12 " Ø , T Y P . 12 " Ø , T Y P . 6" Ø 6" Ø 6 " Ø 6" Ø 55 5555 55 VA V R VA V R VA V R VA V R 6" x 8 " + 1 " A L 6" x 8 " + 1 " A L 6" x 8 " + 1 " A L 6" x 8 " + 1 " A L H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 6" Ø 6" Ø 6 " Ø 6" Ø 57 5757 57 VA V R VA V R VA V R VA V R 6" x 8 " + 1 " A L 6" x 8 " + 1 " A L 6" x 8 " + 1 " A L 6" x 8 " + 1 " A L H. D . H. D . H. D . H. D . 14 " Ø 14 " Ø 14 " Ø 14 " Ø 50 5050 50 VA V R VA V R VA V R VA V R 16 " x 1 4 " + 1 " A L 16 " x 1 4 " + 1 " A L 16 " x 1 4 " + 1 " A L 16 " x 1 4 " + 1 " A L 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D .10 " Ø 10 " Ø 10 " Ø 10 " Ø H . D . H . D . H . D . H . D . H . D . H . D . H . D . H . D . 6" Ø 6" Ø 6 " Ø 6" Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 52 A 52 A 52 A 52 A VA V R VA V R VA V R VA V R 10 " x 1 2 " + 1 " A L 10 " x 1 2 " + 1 " A L 10 " x 1 2 " + 1 " A L 10 " x 1 2 " + 1 " A L H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø 12 " Ø 12 " Ø 12 " Ø 12 " Ø 12 " Ø 12 " Ø 12 " Ø 12 " Ø 52 5252 52 VA V R VA V R VA V R VA V R 10 " x 8 " + 1 " A L 10 " x 8 " + 1 " A L 10 " x 8 " + 1 " A L 10 " x 8 " + 1 " A L 14 " x 1 0 " + 1 " A L 14 " x 1 0 " + 1 " A L 14 " x 1 0 " + 1 " A L 14 " x 1 0 " + 1 " A L 1 4 " x 1 2 " + 1 " A L 1 4 " x 1 2 " + 1 " A L 1 4 " x 1 2 " + 1 " A L 1 4 " x 1 2 " + 1 " A L 12 " Ø 12 " Ø 12 " Ø 12 " Ø 64 6464 64 VA V R VA V R VA V R VA V R 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L H. D . H. D . H. D . H. D . 6" Ø 6" Ø 6 " Ø 6" Ø 15 1515 1510 " x 1 0 " + 1 " A L 10 " x 1 0 " + 1 " A L 10 " x 1 0 " + 1 " A L 10 " x 1 0 " + 1 " A L H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 1 0 " x 1 0 " + 1 " A L 1 0 " x 1 0 " + 1 " A L 1 0 " x 1 0 " + 1 " A L 1 0 " x 1 0 " + 1 " A L H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø 10 " Ø H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 6" Ø 6" Ø 6 " Ø 6" Ø 8" Ø 8" Ø 8 " Ø 8" Ø8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8 " Ø 8 " Ø 8 " Ø 8 " Ø 8" Ø 8" Ø 8 " Ø 8" Ø 1 0 " Ø 1 0 " Ø 1 0 " Ø 1 0 " Ø 59 A 59 A 59 A 59 A VA V R VA V R VA V R VA V R 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L 14 " x 1 2 " + 1 " A L H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 18 1818 18 19 1919 19 17 1717 171717171717171717 17 1717 17 17 1717 17 17 1717 171717171717171717 17 1717 17 17 1717 17 17 1717 17 17 1717 17 17 1717 17 17 1717 17 17 1717 17 17 1717 17 20 2020 20 20 2020 20 17 1717 1717171717 4 44 4 25 2525 25 17 1717 17 17 1717 17 21 2121 21 H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 22 2222 22 23 2323 23 12 " x 8 " E X H . 12 " x 8 " E X H . 12 " x 8 " E X H . 12 " x 8 " E X H . 1 11 1IE F IE F I E F IE F LV T P LV T P LV T P LV T P 18 1818 18 18 1818 18 6" x 6 " 6" x 6 " 6" x 6 " 6" x 6 " 24 2424 24 4 44 4 4 44 4 4 44 4 2 22 2 2 22 2 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MH100Level 00 Mechanical Remodel Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 SC A L E : SC A L E : SC A L E : SC A L E : MH 1 0 0 MH 1 0 0 MH 1 0 0 MH 1 0 0 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 0 M E C H A N I C A L R E M O D E L P L A N 1 11 1 NOTE #DIFFUSER CALLOUT DESCRIPTION 1 11 1 S-1 S-1S-1 S-1 215 CFM, 8"Ø NK S.A. DIFFUSER 215 CFM, 8"Ø NK S.A. DIFFUSER 215 CFM, 8"Ø NK S.A. DIFFUSER 215 CFM, 8"Ø NK S.A. DIFFUSER 2 22 2 R-1 R-1R-1 R-1 22"x10" NK R.A. GRILLE W/ SOUND 22"x10" NK R.A. GRILLE W/ SOUND 22"x10" NK R.A. GRILLE W/ SOUND 22"x10" NK R.A. GRILLE W/ SOUND BOOT BOOT BOOT BOOT 3 33 3 S - 1 S-1S-1 S-1 255 CFM, 10"Ø NK S.A. DIFFUSER 255 CFM, 10"Ø NK S.A. DIFFUSER 255 CFM, 10"Ø NK S.A. DIFFUSER 255 CFM, 10"Ø NK S.A. DIFFUSER 4 44 4 R - 1 R-1R-1 R-1 22"x22" NK R.A. GRILLE W/ SOUND 22"x22" NK R.A. GRILLE W/ SOUND 22"x22" NK R.A. GRILLE W/ SOUND 22"x22" NK R.A. GRILLE W/ SOUND BOOT BOOT BOOT BOOT 5 55 5 S - 1 S-1S-1 S-1 5 0 C F M , 6 " Ø N K S . A . D I F F U S E R 50 CFM, 6"Ø NK S.A. DIFFUSER 50 CFM, 6"Ø NK S.A. DIFFUSER 50 CFM, 6"Ø NK S.A. DIFFUSER 6 66 6 S - 2 S-2S-2 S-2 2 2 5 C F M , 1 0 " Ø N K S . A . D I F F U S E R 225 CFM, 10"Ø NK S.A. DIFFUSER 225 CFM, 10"Ø NK S.A. DIFFUSER 225 CFM, 10"Ø NK S.A. DIFFUSER 7 77 7 S - 1 S-1S-1 S-1 3 6 0 C F M , 1 2 " Ø N K S . A . D I F F U S E R 360 CFM, 12"Ø NK S.A. DIFFUSER 360 CFM, 12"Ø NK S.A. DIFFUSER 360 CFM, 12"Ø NK S.A. DIFFUSER 8 88 8 S - 1 S-1S-1 S-1 1 8 5 C F M , 8 " Ø N K S . A . D I F F U S E R 185 CFM, 8"Ø NK S.A. DIFFUSER 185 CFM, 8"Ø NK S.A. DIFFUSER 185 CFM, 8"Ø NK S.A. DIFFUSER 9 99 9 S - 1 S-1S-1 S-1 1 3 0 C F M , 8 " Ø N K S . A . D I F F U S E R 130 CFM, 8"Ø NK S.A. DIFFUSER 130 CFM, 8"Ø NK S.A. DIFFUSER 130 CFM, 8"Ø NK S.A. DIFFUSER 10 1010 10 S - 2 S-2S-2 S-2 2 3 0 C F M , 1 0 " Ø N K S . A . D I F F U S E R 230 CFM, 10"Ø NK S.A. DIFFUSER 230 CFM, 10"Ø NK S.A. DIFFUSER 230 CFM, 10"Ø NK S.A. DIFFUSER 11 1111 11 S - 1 S-1S-1 S-1 3 3 5 C F M , 1 2 " Ø N K S . A . D I F F U S E R 335 CFM, 12"Ø NK S.A. DIFFUSER 335 CFM, 12"Ø NK S.A. DIFFUSER 335 CFM, 12"Ø NK S.A. DIFFUSER 12 1212 12 S - 1 S-1S-1 S-1 1 4 0 C F M , 8 " Ø N K S . A . D I F F U S E R 140 CFM, 8"Ø NK S.A. DIFFUSER 140 CFM, 8"Ø NK S.A. DIFFUSER 140 CFM, 8"Ø NK S.A. DIFFUSER 13 1313 13 S - 1 S-1S-1 S-1 2 2 0 C F M , 1 0 " Ø N K S . A . D I F F U S E R 220 CFM, 10"Ø NK S.A. DIFFUSER 220 CFM, 10"Ø NK S.A. DIFFUSER 220 CFM, 10"Ø NK S.A. DIFFUSER 14 1414 14 S - 1 S-1S-1 S-1 1 5 0 C F M , 8 " Ø N K S . A . D I F F U S E R 150 CFM, 8"Ø NK S.A. DIFFUSER 150 CFM, 8"Ø NK S.A. DIFFUSER 150 CFM, 8"Ø NK S.A. DIFFUSER 15 1515 15 E - 1 E-1E-1 E-1 1 0 0 C F M , 8 " x 8 " N K E X H A U S T A I R 100 CFM, 8"x8" NK EXHAUST AIR 100 CFM, 8"x8" NK EXHAUST AIR 100 CFM, 8"x8" NK EXHAUST AIR GRILLE GRILLE GRILLE GRILLE 16 1616 16 C O N N E C T N E W 3 6 " x 2 4 " F . O . D U C T T O CONNECT NEW 36"x24" F.O. DUCT TO CONNECT NEW 36"x24" F.O. DUCT TO CONNECT NEW 36"x24" F.O. DUCT TO EXISTING AIR PLENUM. INSTALL DUCT EXISTING AIR PLENUM. INSTALL DUCT EXISTING AIR PLENUM. INSTALL DUCT EXISTING AIR PLENUM. INSTALL DUCT SO THAT THE DUCT OPENING DOES SO THAT THE DUCT OPENING DOES SO THAT THE DUCT OPENING DOES SO THAT THE DUCT OPENING DOES NOT INTERFER WITH EXISTING FIRE NOT INTERFER WITH EXISTING FIRE NOT INTERFER WITH EXISTING FIRE NOT INTERFER WITH EXISTING FIRE SPRINKLER RISER.SPRINKLER RISER.SPRINKLER RISER.SPRINKLER RISER.17 1717 17 1 4 " x 1 2 " + 1 " A L T R A N S F E R A I R O P E N I N G 14"x12"+1"AL TRANSFER AIR OPENING 14"x12"+1"AL TRANSFER AIR OPENING 14"x12"+1"AL TRANSFER AIR OPENING IN WALL ABOVE CEILING W/ SOUND IN WALL ABOVE CEILING W/ SOUND IN WALL ABOVE CEILING W/ SOUND IN WALL ABOVE CEILING W/ SOUND BOOT.BOOT.BOOT.BOOT.18 1818 18 R . A . O P E N I N G I N W A L L A B O V E C E I L I N G R.A. OPENING IN WALL ABOVE CEILING R.A. OPENING IN WALL ABOVE CEILING R.A. OPENING IN WALL ABOVE CEILING AS LARGE AS POSSIBLE.AS LARGE AS POSSIBLE.AS LARGE AS POSSIBLE.AS LARGE AS POSSIBLE.19 1919 19 E X I S T I N G 4 0 " x 2 0 " R . A . O P E N I N G I N EXISTING 40"x20" R.A. OPENING IN EXISTING 40"x20" R.A. OPENING IN EXISTING 40"x20" R.A. OPENING IN WALL ABOVE CEILING.WALL ABOVE CEILING.WALL ABOVE CEILING.WALL ABOVE CEILING.20 2020 20 E - 1 E-1E-1 E-1 2 7 5 C F M , 1 0 " x 1 0 " N K E X H A U S T A I R 275 CFM, 10"x10" NK EXHAUST AIR 275 CFM, 10"x10" NK EXHAUST AIR 275 CFM, 10"x10" NK EXHAUST AIR GRILLE. CONNECT TO EXISTING GRILLE. CONNECT TO EXISTING GRILLE. CONNECT TO EXISTING GRILLE. CONNECT TO EXISTING DUCTWORK.DUCTWORK.DUCTWORK.DUCTWORK.21 2121 21 E - 1 E-1E-1 E-1 7 5 C F M , 6 " x 6 " N K E X H A U S T A I R G R I L L E 75 CFM, 6"x6" NK EXHAUST AIR GRILLE 75 CFM, 6"x6" NK EXHAUST AIR GRILLE 75 CFM, 6"x6" NK EXHAUST AIR GRILLE 22 2222 22 E - 1 E-1E-1 E-1 4 0 0 C F M 1 2 " x 1 2 " N K E X H A U S T A I R 400 CFM 12"x12" NK EXHAUST AIR 400 CFM 12"x12" NK EXHAUST AIR 400 CFM 12"x12" NK EXHAUST AIR GRILLE.GRILLE.GRILLE.GRILLE.23 2323 23 T R A N S I T I O N 1 2 " x 8 " E X H A U S T D U C T A N D TRANSITION 12"x8" EXHAUST DUCT AND TRANSITION 12"x8" EXHAUST DUCT AND TRANSITION 12"x8" EXHAUST DUCT AND CONNECT TO EXISTING 14"x12" DUCT CONNECT TO EXISTING 14"x12" DUCT CONNECT TO EXISTING 14"x12" DUCT CONNECT TO EXISTING 14"x12" DUCT PENETRATING THROUGH EXTERIOR PENETRATING THROUGH EXTERIOR PENETRATING THROUGH EXTERIOR PENETRATING THROUGH EXTERIOR WALL.WALL.WALL.WALL.24 2424 24 3 8 " x 2 8 " O P E N I N G W I T H F I R E / S M O K E 38"x28" OPENING WITH FIRE/SMOKE 38"x28" OPENING WITH FIRE/SMOKE 38"x28" OPENING WITH FIRE/SMOKE DAMPER. TRANSITION AND CONNECT DAMPER. TRANSITION AND CONNECT DAMPER. TRANSITION AND CONNECT DAMPER. TRANSITION AND CONNECT DAMPER TO SUPPLY AIR DUCT.DAMPER TO SUPPLY AIR DUCT.DAMPER TO SUPPLY AIR DUCT.DAMPER TO SUPPLY AIR DUCT.FIRE/SMOKE DAMPER TO BE A FRONT FIRE/SMOKE DAMPER TO BE A FRONT FIRE/SMOKE DAMPER TO BE A FRONT FIRE/SMOKE DAMPER TO BE A FRONT ACCESS TYPE DAMPER TO MOUNT ACCESS TYPE DAMPER TO MOUNT ACCESS TYPE DAMPER TO MOUNT ACCESS TYPE DAMPER TO MOUNT FLUSH TO THE PLENUM SIDE OF THE FLUSH TO THE PLENUM SIDE OF THE FLUSH TO THE PLENUM SIDE OF THE FLUSH TO THE PLENUM SIDE OF THE WALL.WALL.WALL.WALL.25 2525 25 3 0 " x 2 4 " R . A . O P E N I N G I N W A L L A B O V E 30"x24" R.A. OPENING IN WALL ABOVE 30"x24" R.A. OPENING IN WALL ABOVE 30"x24" R.A. OPENING IN WALL ABOVE CEILING WITH FIRE/SMOKE DAMPER.CEILING WITH FIRE/SMOKE DAMPER.CEILING WITH FIRE/SMOKE DAMPER.CEILING WITH FIRE/SMOKE DAMPER. A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 27 0 CL A S S R O O M 26 8 CL A S S R O O M 26 6 ME N ' S R M 26 4 WO M E N ' S R M 26 2 CL A S S R O O M 26 0 CL A S S R O O M 2- M HA L L W A Y 26 7 CU S T R M 26 5 OF F I C E 26 3 OF F I C E 26 1 OF F I C E 25 9 OF F I C E 27 6 CL A S S R O O M 27 2 BI O - C H E M I S T R Y L A B 2- S HA L L W A Y 27 7 A ST O R A G E R M 27 7 CL A S S R O O M 25 5 CL A S S R O O M 2- V LO U N G E 25 8 ST O R A G E 25 3 OF F I C E 25 2 OF F I C E 25 0 OF F I C E 24 8 OF F I C E 24 6 OF F I C E 24 4 OF F I C E 23 0 SE C R E T A R Y / R E C E P T I O N R M 24 3 WO R K R O O M 2- L HA L L W A Y 24 2 OF F I C E 24 0 OF F I C E 23 8 OF F I C E 23 9 OF F I C E 23 7 OF F I C E 23 5 OF F I C E 23 3 OF F I C E 23 6 OF F I C E 23 4 OF F I C E 23 2 OF F I C E 2- K HA L L W A Y 2- J HA L L W A Y 2- D HA L L W A Y 21 4 CH E M I S T R Y L A B 21 3 CH E M I S T R Y S T O C K R M 2- H ST A I R W E L L 21 6 CU S T S T O R 2- G EL E V A T O R 22 0 WO M E N ' S R O O M 22 6 ME N ' S R O O M 22 8 CU S T R M 28 0 BD F R M 2- T ST A I R W E L L 27 9 CL A S S R O O M 22 9 CL A S S R O O M 20 3 A IN S T R U M E N T R M 21 3 A OF F I C E 20 3 CH E M I S T R Y L A B 21 0 CH E M I S T R Y L A B 29 9 CL A S S R O O M 29 7 CL A S S R O O M 28 1 CH E M I S T R Y P R E P R M 20 3 B IN S T R U M E N T R M 2- B HA L L W A Y 2- C ST A I R W E L L 2- A ST A I R W E L L 20 4 CH E M I S T R Y L A B 29 8 OF F I C E 29 6 OF F I C E 29 4 OF F I C E 29 2 OF F I C E 29 1 OF F I C E 29 0 OF F I C E 28 9 OF F I C E 28 7 SE C / R E C E P R M 28 6 OF F I C E 28 5 OF F I C E 28 2 A CH E M S T O C K R M 28 7 A WO R K R O O M 2- U HA L L W A Y 28 2 GE N E R A L C H E M L A B 2- F HA L L W A Y 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø 1 11 1 2 22 2 H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 1 8 " x 1 4 " + 1 " A L 1 8 " x 1 4 " + 1 " A L 1 8 " x 1 4 " + 1 " A L 1 8 " x 1 4 " + 1 " A L 1 11 1 1 11 1 8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . 1 11 1 8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . 1 11 1 1 11 1 8" Ø 8" Ø 8 " Ø 8" Ø H. D . H. D . H. D . H. D . 8" Ø 8" Ø 8 " Ø 8" Ø 8" Ø 8" Ø 8 " Ø 8" Ø8" Ø 8" Ø 8 " Ø 8" Ø 1 11 1 1 11 11111 H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . H. D . 1 4 " Ø 1 4 " Ø 1 4 " Ø 1 4 " Ø 12 " Ø 12 " Ø 12 " Ø 12 " Ø 1 2 " Ø 1 2 " Ø 1 2 " Ø 1 2 " Ø 1 0 " Ø E X H . 1 0 " Ø E X H . 1 0 " Ø E X H . 1 0 " Ø E X H . 27 2 27 2 27 2 27 2 MA V MA V MA V MA V 27 2 27 2 27 2 27 2 EX V EX V E X V EX V 3 33 3 2 22 2 4 44 4 2 " Ø 2 " Ø 2 " Ø 2 " Ø 1 8 " x 1 6 " F . O . 1 8 " x 1 6 " F . O . 1 8 " x 1 6 " F . O . 1 8 " x 1 6 " F . O . 27 2 A 27 2 A 27 2 A 27 2 A EX V EX V E X V EX V 8" Ø 8" Ø 8 " Ø 8" Ø 27 2 B 27 2 B 27 2 B 27 2 B EX V EX V E X V EX V 8" Ø 8" Ø 8 " Ø 8" Ø 5 55 5 5 55 5 7 77 7 16 " Ø 16 " Ø 16 " Ø 16 " Ø 14 " x 1 4 " 14 " x 1 4 " 14 " x 1 4 " 14 " x 1 4 " 6 66 6 6 66 6 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MH102Level 02 Mechanical Remodel Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE #DIFFUSER CALLOUT DESCRIPTION 1 11 1 S-1 S-1S-1 S-1 185 CFM, 8"Ø NK S.A. DIFFUSER 185 CFM, 8"Ø NK S.A. DIFFUSER 185 CFM, 8"Ø NK S.A. DIFFUSER 185 CFM, 8"Ø NK S.A. DIFFUSER 2 22 2 DROP 12"Ø EXHAUST DUCT DOWN TO DROP 12"Ø EXHAUST DUCT DOWN TO DROP 12"Ø EXHAUST DUCT DOWN TO DROP 12"Ø EXHAUST DUCT DOWN TO CHEMICAL FUME HOOD AND CONNECT.CHEMICAL FUME HOOD AND CONNECT.CHEMICAL FUME HOOD AND CONNECT.CHEMICAL FUME HOOD AND CONNECT.TRANSITION AS REQUIRED.TRANSITION AS REQUIRED.TRANSITION AS REQUIRED.TRANSITION AS REQUIRED.3 33 3 E - 2 E-2E-2 E-2 1290 CFM, 16"Ø NK EXHAUST AIR 1290 CFM, 16"Ø NK EXHAUST AIR 1290 CFM, 16"Ø NK EXHAUST AIR 1290 CFM, 16"Ø NK EXHAUST AIR GRILLE GRILLE GRILLE GRILLE 4 44 4 2 " Ø U N D E R H O O D F L A M M A B L E C A B I N E T 2"Ø UNDERHOOD FLAMMABLE CABINET 2"Ø UNDERHOOD FLAMMABLE CABINET 2"Ø UNDERHOOD FLAMMABLE CABINET EXHAUST. SEE DETAIL 2/MH502.EXHAUST. SEE DETAIL 2/MH502.EXHAUST. SEE DETAIL 2/MH502.EXHAUST. SEE DETAIL 2/MH502.5 55 5 R E F E R E N C E P L U M B I N G D R A W I N G S F O R REFERENCE PLUMBING DRAWINGS FOR REFERENCE PLUMBING DRAWINGS FOR REFERENCE PLUMBING DRAWINGS FOR WORK IN THIS AREA.WORK IN THIS AREA.WORK IN THIS AREA.WORK IN THIS AREA.6 66 6 E X V - 2 7 2 A A N D E X V - 2 7 2 B A N D T H I E R EXV-272A AND EXV-272B AND THIER EXV-272A AND EXV-272B AND THIER EXV-272A AND EXV-272B AND THIER ASSOCIATED DUCTWORK AND ASSOCIATED DUCTWORK AND ASSOCIATED DUCTWORK AND ASSOCIATED DUCTWORK AND CONTROLS ARE PART OF ADD.CONTROLS ARE PART OF ADD.CONTROLS ARE PART OF ADD.CONTROLS ARE PART OF ADD.ALTERNATE #2.ALTERNATE #2.ALTERNATE #2.ALTERNATE #2.7 77 7 T H E A I R V A L V E S I N T H I S R O O M ( 2 8 2 ) THE AIR VALVES IN THIS ROOM (282)THE AIR VALVES IN THIS ROOM (282)THE AIR VALVES IN THIS ROOM (282)TO BE REBALANCED TO ACCOMMODATE TO BE REBALANCED TO ACCOMMODATE TO BE REBALANCED TO ACCOMMODATE TO BE REBALANCED TO ACCOMMODATE THE REMOVAL OF 2 FUME HOODS.THE REMOVAL OF 2 FUME HOODS.THE REMOVAL OF 2 FUME HOODS.THE REMOVAL OF 2 FUME HOODS.REFERENCE EQUIPMENT SCHEDULES.REFERENCE EQUIPMENT SCHEDULES.REFERENCE EQUIPMENT SCHEDULES.REFERENCE EQUIPMENT SCHEDULES. SC A L E : SC A L E : SC A L E : SC A L E : MH 1 0 2 MH 1 0 2 MH 1 0 2 MH 1 0 2 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 2 M E C H A N I C A L R E M O D E L P L A N 1 11 1 SINGLE VANE SCHEDULEONE SIDE SQ U A R E E L B O W NO T E S : RADIUS ELBOW BO T H S I D E S 45 DEG. ELBOW 45 DEG. TURNING VANE DETAIL30 DEG. MAX.1/2 W IN S I D E S Q U A R E , O U T S I D E R A D I U S AL L D U C T S ( S U P P L Y , R E T U R N AN D E X H A U S T ) T O H A V E T U R N I N G EL B O W S N O T A L L O W E D . 2. VA N E S I N S Q U A R E E L B O W . 1. W 15 D E G . M A X . TU R N I N G VA N E S SIN G L E BL A D E SINGLE BLADE SMALL LARGE2"R (51mm)4-1/2"(114mm)1-1/2"SP (38mm)3-1/4"(83mm)24GA (0.70mm)22 (0.85mm)22.5 (TYP.)TURNING VANES,SEE DETAIL AND SCHEDULE BELOW C L45° LATERAL TEECONICAL 90° TEE Y-BRANCH 90°BRANCH TAKE-OFF DIMENSIONS FA B R I C A T E D E L B O W DR ADD ONE PIECE FOR EACH ADDITIONAL 18°R = 1.5DD = DUCT SIZE 0-35° ---- 2 PIECE 72-90° ----5 PIECE36-71° ----3 PIECEL DMITERED 90° ELBOW REDUCER OFFSET1A MAX.2" 1- 1 / 4 " A 2A TU R N I N G VA N E S A1-1/4"D45°D = DUCT SIZEDIMENSIONS L = D/2+1"D2" DU C T S I D E . P R O V I D E 1 " T R A I L I N G TO S T A R T A N D S T O P P A R A L L E L W I T H AN G L E O F D I R E C T I O N C H A N G E . V A N E S EX H A U S T ) T O H A V E T U R N I N G V A N E S AL L D U C T S ( S U P P L Y , R E T U R N A N D WIT H S Q U A R E T Y P E E L B O W S A T A N Y ED G E . NO T E : kl=mlm=ofsbqp=^iiltbaHANGER STRAPS `lkpqor`qflk=pq^ka^oapar`q=mbo=pj^`k^=es^`=ar`qe^kdbo=pfwbp=clo=olrka SELF TAPPING HEX HEAD SHEET METAL SCREWS. STRAPS TO BE TIGHT AGAINST DUCT 1"kl=mlm=ofsbqp=^iiltbaTO BE TIGHT AGAINST DUCT.HEAD SHEET METAL SCREWS. STRAPSSELF TAPPING CADMIUM PLATED HEXHANGER STRAPSe^kdbo=pfwbp=clo=ob`q^kdri^o ar`q=mbo=pj^`k^=es^`=ar`q `lkpqor`qflk=pq^ka^oap AN G L E I R O N RO U N D / O V A L D U C T AN G L E I R O N HA N G E R S T R A P S e^ k d b o = p f w b p = c l o = o l r k a = L = l s ^ i ar ` q = m b o = p j ^ ` k ^ = e s ^ ` = a r ` q `l k p q o r ` q f l k = p q ^ k a ^ o a p EN D S O F L I N E R S H A L L B E CO A T E D W I T H A D H E S I V E . ME T A L D U C T GA L V A N I Z E D S H E E T AL L E N D S O F L I N E R T O B E BU T T E D F I R M L Y T O G E T H E R . 1 2 " C . C . M A X . SI Z E D P E R D R A W I N G FR O M E D G E O F L I N E R NO T M O R E T H A N 2 " ( T Y P . ) 2 " DU C T L I N E R AD H E S I V E AD H E R E D T O DU C T W / 1 0 0 % DU C T L I N E R . LI N E R T O B E TO P A N D B O T T O M S E C T I O N OF L I N E R S H A L L O V E R L A P TH E S I D E S FO R S I Z I N G RO U N D D U C T , S E E P L A N S MA D E D U C T . M A X . L E N G T H 6 ' - 0 " . FA S T E N W I T H M A S T I C A N D B I N D I N G HIG H P R E S S U R E R A T E D F A C T O R Y SU P P L Y A I R D I F F U S E R , S E E PL A N S F O R S I Z I N G CE I L I N G ST R A P . S E E D E T A I L T H I S S H E E T BIN D I N G S T R A P RO U N D S H E E T M E T A L D U C T 6" M A X . L E N G T H FA C T O R Y M A D E D U C T 5/8 " S C R E W T I G H T E N I N G B I N D I N G ST R A P O R N Y L O N C I N C H E B A N D . 2" NO T E : FO R I N S U L A T E D D U C T , P R O V I D E O N E AD D I T I O N A L B A N D A R O U N D T H E IN S U L A T I O N . RE T U R N A I R G R I L L E 22 G A . S H E E T ME T A L S K I N GR I L L E LE N G T H AC O U S T I C A L ( 1 2 " M I N . ) W 1" I N T E R I O R LI N I N G , 1 # P C F DE N S I T Y 1 / 2 W ( M I N . 8 " +A L ) 1 / 2 W 1" W I D E H A N G I N G ST R A P SH E E T M E T A L SC R E W , T Y P I C A L W TU R N H A N G E R U N D E R 2" A N D F A S T E N W I T H SH E E T M E T A L S C R E W SH E E T M E T A L D U C T DU C T S E C T I O N LO C K I N G Q U A D R A N T ST R A P 1/2 " R O D 45 ° D U C T C O N N E C T I O N BL A D E W I T H V - G R O O V E BL A D E S E C T I O N 1/2 " R O D BR A N C H D U C T O R R U N O U T TO D I F F U S E R , S E E P L A N S FO R S I Z I N G RE C T A N G U L A R D U C T , S E E PL A N S F O R S I Z I N G LO C K I N G Q U A D R A N T (O N E P E R B L A D E ) ST R A P , R I V E T T O B L A D E (T A C K W E L D R O D SE C U R E L Y T O B L A D E ) 22 G A . B L A D E 1 / 2 " SP R I N G L O A D E D E N D TA C K W E L D O R R I V E T TO B L A D E ( B L A D E M U S T CL E A R L I N E R O R D U C T AP P R O X . 1 / 4 " O N A L L S I D E S ) BL A D E M U L T I P L E S DU C T D E P T H UP T O 1 2 " - 1 B L A D E UP T O 2 0 " - 2 B L A D E S UP T O 3 0 " - 3 B L A D E S NO T E S : EQ U A L C R O S S S E C T I O N A R E A AR E A O F A x C S H A L L B E E Q U A L MIN I M U M A R E A O F A x B S H A L L TO 1 . 5 x A R E A O F A x B . OF B R A N C H D U C T . C HA N D D A M P E R W I T H LO C K I N G Q U A D R A N T A PL A N S F O R S I Z I N G RE C T A N G U L A R D U C T , S E E RO U N D D U C T R U N O U T TO D I F F U S E R , S E E PL A N S F O R S I Z I N G B 45 ° 2.1. VE R I F Y R E Q U I R E D S L E E V E LE N G T H P R I O R T O O R D E R I N G PR O V I D E A C C E S S D O O R T O F I R E DA M P E R L I N K A G E A N D S M O K E DA M P E R A C T U A T O R L A R G E E N O U G H TO S E R V I C E A N D R E S E T D A M P E R . 12 " x 1 2 " M I N I M U M . RE T U R N O R S U P P L Y AIR D U C T , S E E P L A N S FO R S I Z E S DA M P E R A C T U A T O R MIN I M U M A N D M A X I M U M C L E A R A N C E AS R E Q U I R E D B Y M A N U F A C T U R E R FI R E W A L L SL I P C O N N E C T I O N ( T Y P . ) RE T U R N O R S U P P L Y AIR D U C T FI R E / S M O K E D A M P E R . L O C A T E IN W A L L A S R E Q U I R E D B Y MA N U F A C T U R E R SL E E V E G A U G E A S R E Q U I R E D B Y MA N U F A C T U R E R 16 G A . M I N . O R A S R E Q U I R E D B Y MA N U F A C T U R E R A L L A R O U N D DU C T - S E E P L A N S F O R S I Z E , LO C A T I O N A N D C O N T I N U A T I O N NU M B E R HIN G E S 16 X 1 6 24 X 2 4 12 X 1 2 6 X 6 MA X I M U M DIM E N S I O N GA U G E BA C K 24 26 2 2 3 2 22 26 HA N D L E S 22 11 NU M B E R OF O F 2626 2626 DO O R 22 222624 FR A M E BU T T H I N G E 1"x 1 " ( . 0 2 5 x . 0 2 5 ) LO C A T I O N AC C E S S D O O R . S E E PL A N S F O R S I Z E A N D SA S H L O C K GA S K E T DU C T E X T E R I O R DE N S I T Y F I B E R G L A S S DU C T L I N E R 1 " ( . 0 2 5 ) T H I C K ON E A N D O N E H A L F P O U N D NO T E : IN A D D I T I O N T O T H O S E D O O R S S H O W N DO O R S S H O W N I N T H E D R A W I N G S , T H E SH E E T M E T A L C O N T R A C T O R S H A L L IN S T A L L A N A C C E S S D O O R A T E A C H FI R E A N D F I R E / S M O K E D A M P E R . bn r f m j b k q = q ^ d s^ i s b = q ^ d TH E O W N E R TH E P L A N S D I R E C T E D B Y LE T T E R I N G BL A C K F A C E D P L A S T I C IN D I C A T E N O R M A L Y O P E N O R N O R M A L L Y IN D I C A T E S H U T - O F F , B A L A N C I N G , D R A I N E T C . IN D I C A T E C H I L L E D W A T E R , HO T W A T E R , G A S E T C . AN C H O R S E C U R E L Y TO E Q U I P M E N T LA M I N A T E W I T H E N G R A V E D IN D I C A T E E X H A U S T F A N , PU M P , E T C . I N D I C A T E EQ U I P M E N T M A R K A S S H O W N 3/1 6 " M I N I M U M L E T T E R H E I G H T FR O M M A N U F A C T U R E R R E C O M M E N D A T I O N S SA M E A S M O T O R N A M E P L A T E IN D I C A T E - S T A T I C P R E S S U R E , F O O T O F HE A D E T C . A N D R P M I F A P P L I C A B L E LU B . F R E Q U E N C Y : MO T O R R P M / H P : AR E A S E R V E D : LU B R I C A N T : AT : RE F E R T O P L A N S . RP M AT T A C H A R O U N D V A L V E H A N D L E W I T H C H A I N IN D I C A T E T O N S , G P M , C F M E T C . WIT H S T A N D A R D L E T T E R I N G IN D I C A T E G A T E , B A L L , 0. 0 5 1 " T H I C K B R A S S T A G SI Z E : TY P E : IT E M N A M E / # : CA P A C I T Y : CO N T E N T S : FU N C T I O N : PO S I T I O N : CL O S E D O R A S M A R K E D . IN D I C A T E V A L V E S I Z E 3 " M I N I M U M 6" M I N I M U M 1 - 1 / 2 " M I N . 3" NO T E : FR O M M A N U F A C T U R E R R E C O M M E N D A T I O N S 1/8 " M I N I M U M L E T T E R H E I G H T NO T E : CH E C K V A L V E E T C . AS R E Q U I R E D T O S I Z E I N D I C A T E D TR A N S I T I O N F R O M D I S C H A R G E E N D SE E P L A N S F O R S I Z I N G BR A N C H D U C T T O D I F F U S E R S , ON P L A N S . VA V B O X , S E E P L A N S F O R SIZ I N G A N D L O C A T I O N . BE L L T Y P E F I T T I N G VA V B O X A S R E Q U I R E D TR A N S I T I O N T O I N L E T O F AL T E R N A T E T A K E - O F F T Y P E MA I N S U P P L Y D U C T ST R A I G H T D U C T W O R K , P R O V I D E M I N I M U M LE N G T H O F 1 8 " O R 1 . 5 T I M E S I N L E T DU C T D I A M E T E R , W H I C H E V E R I S G R E A T E R . CO N T R O L S E N C L O S U R E , VE R I F Y W H I C H S I D E O F BO X W I T H D R A W I N G S NO L I N E O F S I G H T T H R O U G H CO N S T R U C T E D S O T H E R E I S SO U N D B O O T T O B E TH E S O U N D B O O T . NO T E : W W +2 " W L WA L L W W W+ 2 " LI N E O F S I G H T 1" I N T E R I O R A C O U S T I C A L LI N I N G , 1 l b . D E N S I T Y 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MH501MechanicalDetails22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid Set SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 RE C T A N G U L A R D U C T F I T T I N G S D E T A I L 1 11 1 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ME D I U M V E L O C I T Y D U C T F I T T I N G S D E T A I L 2 22 2 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ROUND DUCT HANGER DETAIL 3 33 3 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 DUCT STRAP HANGER DETAIL 4 44 4 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 OV A L D U C T H A N G E R D E T A I L 5 55 5 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 DU C T L I N E R D E T A I L 6 66 6 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 DU C T T O D I F F U S E R C O N N E C T I O N D E T A I L 7 77 7 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 FA C T O R Y M A D E D U C T D E T A I L 8 88 8 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 SO U N D T R A P D E T A I L 9 99 9 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 BR A N C H D U C T A N D D A M P E R D E T A I L 10 1010 10 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 DU C T C O N N E C T I O N D E T A I L 11 1111 11 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 FI R E / S M O K E D A M P E R D E T A I L 12 1212 12 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 LO W P R E S S U R E D U C T A C C E S S D O O R D E T A I L 13 1313 13 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 ID E N T I F I C A T I O N T A G D E T A I L 14 1414 14 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 VA V B O X D E T A I L 15 1515 15 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 1 MH 5 0 1 MH 5 0 1 MH 5 0 1 TR A N S F E R / R E T U R N A I R S O U N D B O O T D E T A I L 16 1616 16 MAIN SUPPLY DUCT FOR SIZING AND LOCATIONPHOENIX VALVE, SEE PLANS REHEAT COIL WHEREBOX AS REQUIRED INDICATEDINLET OF VAVTRANSITION TO ACCESS DOOR,12"x12" MINIMUMDRAWBANDDRAWBANDSEE PLANS FOR DUCT SIZE AS REQUIRED TO SIZE INDICATEDTRANSITION FROM DISCHARGE END ON PLANS.5' MIN.3' MIN.DIFFUSERS, SEEBRANCH DUCT TO PLANS FOR SIZING.DUCT SIZE.WALLTRANSITION FROM FUME HOOD RECTANGULAR OUTLET TO ROUND EXHAUST DUCT,SEE PLANS FOR EXHAUST FL A M M A B L E S T O R A G E CA B I N E T UNION, TYPICAL2"VALVE CH E M I C A L F U M E HO O D EX H A U S T D U C T FLOORUNISTRUT SUPPORT SYSTEM2" TYPE L COPPER PIPE3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MH502MechanicalDetails22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetSCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE MH 5 0 2 MH 5 0 2 MH 5 0 2 MH 5 0 2 PHOENIX VALVE WITH REHEAT COIL DETAIL 1 11 1 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MH 5 0 2 MH 5 0 2 MH 5 0 2 MH 5 0 2 CH E M I C A L F U M E H O O D C O N N E C T I O N D E T A I L 2 22 2 (E ) 3 " H W R (E ) 3 " H W S HW R / S (E ) 1 - 1 / 2 " (E ) 3 / 4 " HW R / S (E ) 2 " H W R / S (E ) 1 " HW R / S (E ) 1 - 1 / 2 " H W R / S (E ) 3 " H W R / S (E ) 1 - 1 / 4 " HW R / S (E ) 1 - 1 / 4 " HW R / S dbkbo^i=klqbp A.A.A.A.ALL HWS/R BRANCH LINES SERVING VAVR BOXES ALL HWS/R BRANCH LINES SERVING VAVR BOXES ALL HWS/R BRANCH LINES SERVING VAVR BOXES ALL HWS/R BRANCH LINES SERVING VAVR BOXES SHALL BE 3/4" UNLESS OTHERWISE NOTED.SHALL BE 3/4" UNLESS OTHERWISE NOTED.SHALL BE 3/4" UNLESS OTHERWISE NOTED.SHALL BE 3/4" UNLESS OTHERWISE NOTED.A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 66 ME N ' S R M 64 WO M E N ' S R M O- C HA L L W A Y O- A VE S T I B U L E 69 ME C H A N I C A L R O O M 68 CU S T R M 59 CO M P U T E R L A B 59 D DA R K R O O M 59 E FI L M 59 C VE S T I B U L E 51 PH O T O S T U D I O 59 A EQ U I P / C H E C K O U T 59 B ST O R A G E 57 OF F I C E 55 OF F I C E 50 CL A S S R O O M 0- H VE S T I B U L E 51 B CH A N G I N G 52 C ST O R A G E 52 PH Y S I C S L A B 52 B AC O U S T I C S S T U D I O 52 A OP T I C S L A B 67 ME C H R M O- D EL E V A T O R 18 ST O R A G E 16 CU S T O F F I C E 14 CU S T O D I A L L A U N D R Y R M 12 ME C H R M 0- K EL E V A T O R 10 ME C H A N I C A L R M O- B ST A I R W E L L 63 ST O R A G E 64 6464 64 VA V R VA V R VA V R VA V R 0 00 0 ----C CC C VA V R VA V R VA V R VA V R 59 A 59 A 59 A 59 A VA V R VA V R VA V R VA V R 57 5757 57 VA V R VA V R VA V R VA V R 55 5555 55 VA V R VA V R VA V R VA V R 1 11 1CHCHCHCH 2 22 2CHCHCHCH 52 A 52 A 52 A 52 A VA V R VA V R VA V R VA V R 52 5252 52 VA V R VA V R VA V R VA V R 50 5050 50 VA V R VA V R VA V R VA V R 3 33 3CHCHCHCH 51 5151 51 VA V R VA V R VA V R VA V R 59 D 59 D 59 D 59 D VA V R VA V R VA V R VA V R 59 5959 59 VA V R VA V R VA V R VA V R 1" H W S / R 1" H W S / R 1" H W S / R 1" H W S / R 1 11 1----1 / 4 " H W S / R 1/ 4 " H W S / R 1/ 4 " H W S / R 1/ 4 " H W S / R 1 11 1----1 / 4 " H W S / R 1/ 4 " H W S / R 1/ 4 " H W S / R 1/ 4 " H W S / R 1 11 1 2 22 2 3 33 34444 1 11 1 S S S S SS S S S S S S S 1" H W S / R 1" H W S / R 1" H W S / R 1" H W S / R 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MP200Level 00 Mechanical Piping Remodel Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 SC A L E : SC A L E : SC A L E : SC A L E : MP 2 0 0 MP 2 0 0 MP 2 0 0 MP 2 0 0 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 0 M E C H A N I C A L P I P I N G R E M O D E L P L A N 1 11 1 NOTE # DESCRIPTION 1 11 1 CONNECT NEW HWS/R PIPING TO EXISTING PIPING.CONNECT NEW HWS/R PIPING TO EXISTING PIPING.CONNECT NEW HWS/R PIPING TO EXISTING PIPING.CONNECT NEW HWS/R PIPING TO EXISTING PIPING.REDUCE FROM EXISTING PIPE SIZE AS REQUIRED.REDUCE FROM EXISTING PIPE SIZE AS REQUIRED.REDUCE FROM EXISTING PIPE SIZE AS REQUIRED.REDUCE FROM EXISTING PIPE SIZE AS REQUIRED.2 22 2 REPLACE EXISTING CONTROL VALVE WITH NEW REPLACE EXISTING CONTROL VALVE WITH NEW REPLACE EXISTING CONTROL VALVE WITH NEW REPLACE EXISTING CONTROL VALVE WITH NEW AND RECONNECT EXISTING HWS/R TO EXISTING AND RECONNECT EXISTING HWS/R TO EXISTING AND RECONNECT EXISTING HWS/R TO EXISTING AND RECONNECT EXISTING HWS/R TO EXISTING CABINET HEATER. PLACE CABINET HEATER IN FULL CABINET HEATER. PLACE CABINET HEATER IN FULL CABINET HEATER. PLACE CABINET HEATER IN FULL CABINET HEATER. PLACE CABINET HEATER IN FULL OPERATION.OPERATION.OPERATION.OPERATION.3 33 3 I N S T A L L N E W B A L L V A L V E S I N E X I S T I N G 2 " H W S / R INSTALL NEW BALL VALVES IN EXISTING 2" HWS/R INSTALL NEW BALL VALVES IN EXISTING 2" HWS/R INSTALL NEW BALL VALVES IN EXISTING 2" HWS/R LINES.LINES.LINES.LINES.4 44 4 I N S T A L L N E W B A L L V A L V E S I N E X I S T I N G 1 " H W S / R INSTALL NEW BALL VALVES IN EXISTING 1" HWS/R INSTALL NEW BALL VALVES IN EXISTING 1" HWS/R INSTALL NEW BALL VALVES IN EXISTING 1" HWS/R LINES.LINES.LINES.LINES. A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 27 0 CL A S S R O O M 26 8 CL A S S R O O M 26 6 ME N ' S R M 26 4 WO M E N ' S R M 26 2 CL A S S R O O M 26 0 CL A S S R O O M 2- M HA L L W A Y 26 7 CU S T R M 26 5 OF F I C E 26 3 OF F I C E 26 1 OF F I C E 25 9 OF F I C E 27 6 CL A S S R O O M 27 2 BI O - C H E M I S T R Y L A B 2- S HA L L W A Y 27 7 A ST O R A G E R M 27 7 CL A S S R O O M 25 5 CL A S S R O O M 2- V LO U N G E 25 8 ST O R A G E 25 3 OF F I C E 25 2 OF F I C E 25 0 OF F I C E 24 8 OF F I C E 24 6 OF F I C E 24 4 OF F I C E 23 0 SE C R E T A R Y / R E C E P T I O N R M 24 3 WO R K R O O M 2- L HA L L W A Y 24 2 OF F I C E 24 0 OF F I C E 23 8 OF F I C E 23 9 OF F I C E 23 7 OF F I C E 23 5 OF F I C E 23 3 OF F I C E 23 6 OF F I C E 23 4 OF F I C E 23 2 OF F I C E 2- K HA L L W A Y 2- J HA L L W A Y 2- D HA L L W A Y 21 4 CH E M I S T R Y L A B 21 3 CH E M I S T R Y S T O C K R M 2- H ST A I R W E L L 21 6 CU S T S T O R 2- G EL E V A T O R 22 0 WO M E N ' S R O O M 22 6 ME N ' S R O O M 22 8 CU S T R M 28 0 BD F R M 2- T ST A I R W E L L 27 9 CL A S S R O O M 22 9 CL A S S R O O M 20 3 A IN S T R U M E N T R M 21 3 A OF F I C E 20 3 CH E M I S T R Y L A B 21 0 CH E M I S T R Y L A B 29 9 CL A S S R O O M 29 7 CL A S S R O O M 28 1 CH E M I S T R Y P R E P R M 20 3 B IN S T R U M E N T R M 2- B HA L L W A Y 2- C ST A I R W E L L 2- A ST A I R W E L L 20 4 CH E M I S T R Y L A B 29 8 OF F I C E 29 6 OF F I C E 29 4 OF F I C E 29 2 OF F I C E 29 1 OF F I C E 29 0 OF F I C E 28 9 OF F I C E 28 7 SE C / R E C E P R M 28 6 OF F I C E 28 5 OF F I C E 28 2 A CH E M S T O C K R M 28 7 A WO R K R O O M 2- U HA L L W A Y 28 2 GE N E R A L C H E M L A B 2- F HA L L W A Y 27 2 27 2 27 2 27 2 MA V MA V MA V MA V 1" H W S / R 1" H W S / R 1" H W S / R 1" H W S / R 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MP202Level 02 Mechanical Piping Remodel Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE # DESCRIPTION SC A L E : SC A L E : SC A L E : SC A L E : MP 2 0 2 MP 2 0 2 MP 2 0 2 MP 2 0 2 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 2 M E C H A N I C A L P I P I N G R E M O D E L P L A N 1 11 1 WALL, CEILING STRUCTURAL OF THE DIMENSION TABULATED FOR THE LARGER PIPE, PLUS ONE-HALF OF THE DIMENSION TABULATED FOR THE SMALLER PIPE, TO DET ERMINE THE MINIMUMNOTES:OR OTHER MEMBER 3 1/2"4 1/2"DIMENSIONMINIMUM CENTERLINE SPACING 5 1/2"6 1/2"2"-2 1/2"6"8"3"-3 1/2"5"4"PIPE SIZE 1"-1 1/4"-1 1/2"1/2"-3/4"NOMINAL 8}"9"10"8"7 1/2"16"14"13"12"11"DIMENSION 5"7"6"ADIMENSION 6"8"10"BINSULATED PIPEAB C C 5"8"7 1/2"6"5"11"9"7"6"DIMENSION 4"C D 3"4"OR OTHER MEMBERSTRUCTURALWALL, CEILING BARE PIPEED 1. DIM "C": WHERE PIPES OF DIFFERENT SIZE ARE RUN PARALLEL, USE ONE-HALF CENTER LINE SPACING BETWEEN ADJACENT RUNS.2. TABLE APPLIES ONLY TO PIPING RUNS WHICH ARE NOT DIMENSIONED ON THE PIPING PLANS.~~~SPLIT RING ROD SIZE HANGERS SIZES AND SPACING ARE FOR SINGLE PIPES. HAN GER ROD LOADING FOR TRAPEZE HANGERS SHALL NOT EXCEED THE TOTAL LOAD ING INDICATED.IF SMALLER ROD SIZE IS USED, DECREASE MAXIMUN SPACI NG SO THAT TOTAL LOADING IS NOT EXCEEDED. SUPPORT FROM STRUCTURE PAN EL POINTS.UP TO 2000 LBS. USE 1" AND SMALLERMAX. SPACING NOTE:5" - 8"2-1/2" - 4"1-1/4" - 2"PIPE SIZE 12 16810TRAPEZE HANGER PIPE LOAD 2.5/20 50/80020/2406/60WEIGHT/FT. TOTALP-1001.DOUBLE NUT HANGER "UNISTRUT" 1-5/8"UP TO 700 LBS. USE P-1000, FOR LOADINGCHANNEL-FOR LOADINGROD. TYPICAL 3/8"5/8"7/8"3/8"CALSIUM SILICATE THERMAL INSULATION INSERT 360 DEG.COVERAGE/ENCASEMENT WITH GALVANIZED PROTECTION SHIELD, 360 DEG. COVERAGE/ENCASEMENTPIPE INSULATION CLEVIS HANGER C I N C H A N C H O R S THRU-BOLT CINCH ANCHORSANGLEADJUSTABLEPIPE STAND RODSTEEL PLATE BLOCK WALLWELDED STEEL WALL BRACKET U-BOLT STEEL STRAPTURNBUCKLEEYE BOLTSOR BEAM/TRUSS U-BOLTSWALL BRACKETSTEEL OFFSET EYE BOLT PIPE CLAMPTURNBUCKLERODCONNECTIONINSERTS CLAMPSI-BEAMANGLEOR BEAM/TRUSS CONNECTION ROD U-BOLTSINSERTS NOTE:WHERE PIPES ARE INSULATED, THE INSULATION IS TO PASS THROUGH THE CLAMP WITH EITHER CALCIUM SILICATE BLOCKERS OR INSULATION SHIELDS AS REQUIRED. FI V E P I P E D I A M E T E R S M I N I M U M FI V E P I P E D I A M E T E R S M I N I M U M FL O W V E N T U R I O R BA L A N C I N G D E V I C E VA L V E O R O T H E R F I T T I N G DIR E C T I O N O F F L O W DIR E C T I O N OF F L O W FIT T I N G VA L V E O R O T H E R TW O P I P E D I A M E T E R S M I N I M U M FS RE D U C E R ( T Y P I C A L ) UN I O N ( T Y P I C A L ) MA I N O R B R A N C H L I N E BA L L V A L V E AIR C H N A M E R 1- 1 / 4 " x 1 2 " L O N G HIG H P O I N T 3/8 " WA L L S , U S E A S G A C O U S T I C A L S E A L A N T . FO R P E N E T R A T I O N S T H R O U G H S O U N D NO T E : ST A N D A R D W E I G H T S T E E L P I P E SL E E V E O F S I Z E T O P A S S P I P E FI N I S H E D E S C U T C H E O N P L A T E FL U S H A G A I N S T W A L L A N D O F SIZ E T O C O M P L E T E L Y C O V E R OP E N I N G FI N I S H E D W A L L S U R F A C E PI P I N G E X P O S E D T O V I E W CO N C E A L E D P I P I N G TE R M I N A T E S L E E V E F L U S H W I T H FI N I S H E D W A L L S U R F A C E S SE A L O R C A U L K S L E E V E S T H R U FI R E W A L L S I N A S M O K E T I G H T MA N N E R PI P E A N D I N S U L A T I O N T O B E CE N T E R E D I N S L E E V E - D O N O T SU P P O R T P I P E F R O M S L E E V E IN T E R I O R W A L L S HW R MA N U A L A I R V E N T HW S SH U T - O F F B A L L V A L V E ( T Y P . ) AIR FL O W PR O V I D E 1 / 2 " B A L L VA L V E F O R E A C H VE N T H E A D E R CO P P E R T E E W / TH R E A D E D I N S E R T & P / T P L U G . 1/2 " B A L L V A L V E W/ H O S E E N D & C A P 2- W A Y M O D U L A T I N G C O N T R O L VA L V E W / U N I O N E N D S CO P P E R PI P E CO P P E R PI P E NO T E S : 1. I N S T A L L V A L V E S A S C L O S E T O C O I L A S P O S S I B L E . MIN . 5 P I P E D I A M E T E R S RE D U C E R W/ M E M O R Y S T O P & I N D I C A T O R , P A T R A T E D F L O W VE N T U R I F O R 2 0 " T O 5 0 " W . G . WIL L N O T B E A C C E P T E D ) . S E L E C T (R E F R I G E R A T I O N F L A R E C O N N S . VE N T U R I W / S C H R A D E R V A L V E S FL O W S E T A C C U S E T T E R V A L V E TH R E A D E D T O SW E A T C O N N . SW E A T C O N N . TH R E A D E D T O & P / T P L U G . TH R E A D E D I N S E R T CO P P E R T E E W / 2. V A L V E S H A L L B E I N S T A L L E D W I T H I N 2 ' - 0 " O F V A LV E . B A B A VA L V E W / U N I O N E N D S MIN . 5 P I P E D I A M E T E R S 3- W A Y M O D U L A T I N G C O N T R O L A SH U T - O F F B A L L V A L V E ( T Y P . ) VA L V E S ( R E F R I G E R A T I O N F L A R E BA L A N C I N G V A L V E W / S C H R A D E R W/ M E M O R Y S T O P & I N D I C A T O R , CIR C U I T B A L A N C E V A L V E CO N N S . W I L L N O T B E A C C E P T E D ) . W/ H O S E E N D & C A P 2. V A L V E S & S H A L L B E I N S T A L L E D W I T H I N 2 '- 0 " O F V A L V E 1. I N S T A L L V A L V E S A S C L O S E T O C O I L A S P O S S I B L E . TH R E A D E D T O S W E A T NO T E S : C B CO N N E C T I O N FL O W AIR C 1/2 " B A L L V A L V E TH R E A D E D I N S E R T & P / T P L U G . BA L L V A L V E W / ME M O R Y S T O P & CO P P E R T E E W / IN D I C A T O R B VE N T H E A D E R MA N U A L A I R V E N T VA L V E F O R E A C H PR O V I D E 1 / 2 " B A L L IN S E R T A N D P / T P L U G CO P P E R T E E W I T H T H R E A D E D TH R E A D E D T O S W E A T CO N N E C T I O N N. O . N . C . C NO T E S : HW S RE D U C E R HW R A 1.2. VA L V E P O R T I N G I S D I A G R A M T I C . F I E L D V E R I F Y A C T U A L P OR T I N G O F T O B E IN S T A L L E D V A L V E ( S ) P R I O R T O I N S T A L L A T I O N I N S U R I N G P RO P E R F L O W PA T T E R N . TY P I C A L F O R V A V R H W C O I L S W H E R E I N D I C A T E D O N D R A W I N GS . AN C H O R I N T O W A L L ( 3 / 8 " D I A . x 3 " ) UN I S T R U T P I P E C L A M P PI P E I N S U L A T I O N UN I S T R U T C H A N N E L WA L L HIG H D E N S I T Y C A L C I U M S I L I C A T E IN S U L A T I O N I N S E R T 3 6 0 D E G . CO V E R A G E / E N C A S E M E N T GA L V A N I Z E D P R O T E C T I O N SH I E L D . 3 6 0 D E G . CO V E R A G E / E N C A S E M E N T 16 G A G E M I N I M U M ( T Y P . ) CO N C R E T E S L A B CH A N N E L G A L V A N I Z E D 1- 5 / 8 " x 1 - 5 / 8 " U N I S T R U T UN I S T R U T P I P E C L A M P BO L T S , 3 " L O N G . 2- 3 / 8 " D I A . E X P A N S I O N 3/8 " x 4 " x 8 " P L A T E W I T H 3" x 3 " x 3 / 1 6 " A N G L E 1/4 AD J U S T M E N T O F T E N S I O N DO U B L E N U T T O A L L O W PI P I N G 1/4 PI P I N G HIG H D E N S I T Y C A L S I U M S I L I C A T E IN S U L A T I O N I N S E R T , 3 6 0 D E G . CO V E R A G E / E N C A S E M E N T ( T Y P I C A L ) . GA L V A N I Z E D P R O T E C T I O N S H I E L D 36 0 D E G . C O V E R A G E / E N C A S E M E N T (T Y P I C A L ) GA L V A N I Z E D (G A L V A N I Z E D ) GA L V A N I Z E D GA L V A N I Z E D EX T E R I O R P I P E IN S U L A T I O N W I T H EM B O S E D A L U M I N U M JA C K E T EQ U I P M E N T SID E SY S T E M SID E RE D U C E R , T Y P I C A L BO T H S I D E S CIR C U I T B A L A N C E VA L V E ME T E R C O N N E C T I O N PO I N T S UN I O N 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????MP501MechanicalPiping Details22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetSCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE MP501 MP501 MP501 MP501PIPE CLEARANCE DATA DETAIL 1 11 1 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE MP501 MP501 MP501 MP501PIPE HANGER DETAIL 2 22 2 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE MP501 MP501 MP501 MP501TYPICAL PIPE SUPPORTS DETAIL 3 33 3 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MP 5 0 1 MP 5 0 1 MP 5 0 1 MP 5 0 1 BA L A N C E / F L O W D E V I C E I N S T A L L A T I O N D E T A I L 4 44 4 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MP 5 0 1 MP 5 0 1 MP 5 0 1 MP 5 0 1 MA N U A L A I R V E N T D E T A I L 5 55 5 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MP 5 0 1 MP 5 0 1 MP 5 0 1 MP 5 0 1 PI P E P E N E T R A T I O N D E T A I L 6 66 6 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MP 5 0 1 MP 5 0 1 MP 5 0 1 MP 5 0 1 2 -WA Y V A V H E A T I N G C O I L P I P I N G D E T A I L 7 77 7 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MP 5 0 1 MP 5 0 1 MP 5 0 1 MP 5 0 1 3 -WA Y V A V H E A T I N G C O I L P I P I N G D E T A I L 8 88 8 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MP 5 0 1 MP 5 0 1 MP 5 0 1 MP 5 0 1 WA L L M O U N T P I P E S U P P O R T D E T A I L 9 99 9 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MP 5 0 1 MP 5 0 1 MP 5 0 1 MP 5 0 1 EX T E R I O R P I P E S U P P O R T D E T A I L 10 1010 10 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E MP 5 0 1 MP 5 0 1 MP 5 0 1 MP 5 0 1 CI R C U I T B A L A N C I N G V A L V E D E T A I L 11 1111 11 qe b o j l p q ^ q f ` = j f u f k d = s ^ i s b p _^ ` h c i l t = m o b s b k q b o = p ` e b a r i b t^ q b o = e ^ j j b o = ^ o o b p q b o = p ` e b a r i b WHA 4.5.6.3.2.1.GVTRCOWCORDFCOFSFD NIC CWV (E)DI CA mi r j _ f k d = ^ _ _ o b s f ^ q f l k p mi r j _ f k d = c f u q r o b = p ` e b a r i b mirj_fkd=pvj_li=ibdbka dbkbo^i=mirj_fkd=klqbp DIR E C T W A S T E DE S C R I P T I O N WA L L C L E A N O U T SO I L / W A S T E CL E A N O U T DO M E S T I C C O L D W A T E R DO M E S T I C H O T W A T E R DE S C R I P T I O N VE N T T H R O U G H R O O F VT R DH W SY M B O L DC W CO SY M B O L WC OVW VE N T DW FL O O R D R A I N - 6 " S Q U A R E S T A I N L E S S S T E E L S T R A I N E R FD - 1 DE S C R I P T I O N SY M B O L P- 1 A 2" HO T CO L D 1" WA S T E 3" 2" VE N T 2" WA T E R C L O S E T - W A L L M O U N T E D - A D A C O M P L I A N T 3/4 " 3" 2 " 2" TR A P IN T IN T UR I N A L - W A L L M O U N T E D - S T A N D A R D P- 2 A P- 1 B 3" 2 " WA T E R C L O S E T - W A L L M O U N T E D S T A N D A R D IN T 3/4 " 3" 2 " IN T UR I N A L - W A L L M O U N T E D - A D A C O M P L I A N T P- 2 B RE M A R K S HO S E B I B B - C O L D , W I T H V A C U U M B R E A K E R HO S E B I B B - H O T , W I T H V A C U U M B R E A K E R FL O O R C L E A N O U T , N I C K E L B R O N Z E S C O R I A T E D T O P WA L L C L E A N O U T , S T A I N L E S S S T E E L R O U N D C O V E R WC O FC O HB - 2 HB - 1 LA V A T O R Y - W A L L M O U N T - A D A C O M P L I A N T P- 3 1/2 " 1/2 " 1- 1 / 2 " 2 " 1- 1 / 2 " 1" 3/4 " - --------- ---- --- ---3/4 " - ---- ---- ---- FIX T U R E C O U N T FC # HA N D S I N K - C O U N T E R M O U N T E D P- 4 A 1/2 " 1 / 2 " 2" 1- 1 / 2 " 1- 1 / 2 " - LA B S I N K - C O U N T E R M O U N T E D P- 4 B 1/2 " 1 / 2 " 2" 1- 1 / 2 " 1- 1 / 2 " - FLOOR DRAIN, FLOOR SINK OR ROOF DRAIN GAS (NATURAL GAS)DOMESTIC HOT WATER SEWER OR WASTEVENT THROUGH ROOF VENTCOLD WATERTHERMOMETERPRESSURE REDUCING VALVE - (PRV)SAFETY OR RELIEF VALVEFLOOR CLEAN OUT WALL CLEAN OUT CLEAN OUTGAS SHUT OFF VALVE (GAS COCK)DROP IN PIPE RISE IN PIPE VALVE IN RISE GAS TYPE WATER HAMMER ARRESTORCAPBALL VALVESYMBOLUNIONDESCRIPTION ALL PLUMBING SHALL BE DONE IN ACCORDANCE WITH THE L ATEST ADOPTED EDITION OFVALVE WITH HAND WHEEL. VALVE SHALL BE BALL TYPE, Q UARTER TURN AS APPROVEDALL WALL-HUNG PLUMBING FIXTURES SHALL BE SECURELY A TTACHED TO AND SUPPORTEDTHE CONTRACTOR SHALL VERIFY ALL PLUMBING FIXTURES, EQUIPMENT REQUIREMENTS AND LOCATIONS, AND ALL RELATED UTILITIES WITH THE MECHA NICAL AND ARCHITECTURAL PLANS AND SPECIFICATIONS AND SHALL PROVIDE ALL SERV ICES AS REQUIRED.BY FLOOR-MOUNTED CARRIERS OF ALL-METAL CONSTRUCTION . FIXTURE HANGERS OR ARMS SHALL BE SUPPORTED FREE OF THE FINISHED WALL. HANG ERS SHALL BE BY WADE,EACH INDIVIDUAL FIXTURE SUPPLY SHALL BE PROVIDED WI TH A CHROME-PLATED STOP BY ENGINEER. STOPS SHALL BE ON BOTH HOT AND COLD WA TER LINES.FIXTURES AND ACCESSORIES SHALL BE AS SPECIFIED. EA CH ITEM SHALL BE COMPLETE WITH CHROME-PLATED BRASS TRIM. SEE PLUMBING FIXTUR E SCHEDULE.CAULK WITH SILICONE COMPOUND AROUND ALL FIXTURES AT INTERFACE WITH WALLS THE IDAHO PLUMBING CODE AND/OR LOCAL ORDINANCES.SMITH, JOSAM, OR ZURN.AND/OR FLOOR.NEW CONNECTION SYMBOL NOT IN CONTRACT COMBINATION WASTE VENT EXISTING MA N U F A C T U R E R / M O D E L # WH A - A WH A - B WH A - C PP P S C - 5 0 0 PP P S C - 7 5 0 PP P S C - 1 0 0 0 MA R K PE R P D I S T A N D A R D P D I - W H 2 0 1 PE R P D I S T A N D A R D P D I - W H 2 0 1 PE R P D I S T A N D A R D P D I - W H 2 0 1 1- 1 1 12 - 3 2 33 - 6 0 1/2 " 3/4 " 1" FIX T U R E U N I T S I N L E T S I Z E RE M A R K S SE E S P E C I F I C A T I O N 2 2 4 2 0 0 SE R V I C E S I N K - F L O O R M O U N T E D P- 5 3/4 " 3" 3/4 " - 2" 3" SE R V I C E S I N K 1/2 " SE R I V C E SIZ E LF 0 0 9 S NU M B E R 'W A T T ' S ' M A N U F A C T U R E R SY M B O L BF P - 1 QT Y . 2 SE E S P E C I F I C A T I O N 2 3 0 5 2 3 TE P I D ------------- DE I O N I Z E D W A T E R S P O U T P- 6 - 3" - AD D . A L T E R N A T E # 5 2" 3" - EM E R G E N C Y S H O W E R / E Y E W A S H S T A T I O N P- 7 - 3" - - 2" 3" 1- 1 / 4 " DI 1/2 " DIF F E R E N T I A L PR E S S U R E AL L O W A B L E MA N U F A C T U R E R AN D M O D E L N O . SY M B O L LO C A T I O N FL O W GP M RA T E RE M A R K S OU T L E T WA T E R TE M P . ° F SIZ E OU T L E T IN L E T SIZ E MV - 1 W A T T S L F U S G - B - M 2 U N D E R L A V A T O R Y 2 5 1 0 5 1 / 2 " 1/2 " A D J U S T A B L E / A S S E 1 0 7 0 MV - 2 G U A R D I A N G 3 8 0 0 L F EM E R G E N C Y S H O W E R / E Y E W A S H 20 5 7 5 1 " 1" A D J U S T A B L E / A N S I Z 3 5 8 . 1 PS I DA R K R O O M S I N K P- 4 C 1/2 " 1 / 2 " 2" 1- 1 / 2 " 1- 1 / 2 " - LA B S I N K - C O U N T E R M O U N T E D P- 4 D 1/2 " 1 / 2 " 2" 1- 1 / 2 " 1- 1 / 2 " - -- DEIONIZED WATER (ADD. ALTERNATE #5)COMPRESSED AIR GA S ----------------- AIR ----------------- GA S T U R R E T P- 8 - 3" - - 2" 3" - CO M P R E S S E D A I R T U R R E T P- 9 - 3" - - 2" 3" - 1/2 " - -1/2 " 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????P-001PlumbingSchedulesand Symbol Legend22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid Set (E ) 1 / 2 " (E ) 3 / 4 " (E ) W H (E ) 3 / 4 " ( E ) L A (E ) 1 - 1 / 2 " A LA L A L A WH (E ) 3 / 4 " LA (E ) 1 - 1 / 2 " L A (E ) 3 / 4 " (E ) 2 - 1 / 2 " LA (E ) 1 / 2 " (E ) 1 - 1 / 2 " L A (E ) 1 - 1 / 4 " (E ) 3 / 4 " (E ) 2 " (E ) 3 / 4 " (E ) 2 - 1 / 2 " (E ) 1 " (E ) 3 / 4 " (E ) W H (E ) I C W IH W (E ) 1 - 1 / 4 " (E ) 2 " G A S (E ) F D (E ) 3 " (E ) 1 - 1 / 2 " (E ) 2 " (E ) 2 " W A S T E F R O M AB O V E . D R O P B E L O W SL A B . FR O M A B O V E (E ) 4 " R D L E A D E R (E ) 6 " R D (E ) 8 " R D L E A D E R DR O P S B E L O W FL O O R S L A B (E ) 8 " RD (E ) 8 " ( E ) R D FR O M A B O V E (E ) 4 " R D L E A D E R (E ) 5 " (E ) 4 " R D L E A D E R FR O M A B O V E UP T O E X I S T I N G PL A N T E R D R A I N (E ) 2 " PL A N T E R D R A I N UP T O E X I S T I N G CO (E ) D U C T W O R K (S E E M E C H A N I C A L D W G S ) (E ) 1 - 1 / 4 " I H W L A (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 " I H W (E ) I H W LA (E ) I C W (E ) 1 " I H W (E ) R D L E A D E R FR O M A B O V E D C W D H W D H W R (E ) 1 " I H W (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " I H W R ( E ) R D (E ) 4 " (E ) R D (E ) 4 " F R O M AB O V E (E ) 1 / 2 " (E ) 3 / 4 " IH W R IH W R (E ) 3 / 4 " I H W R (E ) % % 2 0 8 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 1 / 2 " I H W R I H W ( E ) I C W (E ) 4 " (E ) R D L E A D E R FR O M A B O V E (E ) 1 / 2 " (E ) 3 / 4 " DC W DC W TO ( E ) U R I N A L S AB O V E TO ( E ) L A V ' S . AB O V E (E ) 1 / 2 " D C W R I S E R TO ( E ) D R I N K I N G FO U N T A I N S A B O V E (E ) 2 " D C W D C W (E ) 1 / 2 " IC W DC W D C W (E ) 3 / 4 " (E ) 3 / 4 " D C W (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " ( E ) I C W I C W (E ) 3 / 4 " (E ) 1 / 2 " (E ) 1 / 2 " D C W (E ) 1 - 1 / 2 " (E ) 3 / 4 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 1 - 1 / 2 " (E ) 1 - 1 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 PD 4 0 1 PD 4 0 1 PD 4 0 1 PD 4 0 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PD100Level 00 Plumbing Demolition Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES NOTE # DESCRIPTION 1 11 1 NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION. SC A L E : SC A L E : SC A L E : SC A L E : PD 1 0 0 PD 1 0 0 PD 1 0 0 PD 1 0 0 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 0 P L U M B I N G D E M O L I T I O N P L A N 1 11 1 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 LE A D E R D N . (E ) 4 " R D A W (E ) R O (E ) L G L G L G L A L A LG RO (E ) R O L G R O (E ) L A RO L A R O LA L G LA LG (E ) 4 " A W A W (E ) C O (E ) 3 " (E ) 4 " (E ) 2 " A W CO AW (E ) 3 " V T R (E ) 4 " (E ) 4 " AW AW(E ) 6 " (E ) 4 " A W (E ) A W (E ) 3 " CO (E ) 3 " A W (E ) 2 " (E ) 3 " (E ) 3 " V E N T U P (E ) 3 " V T R (E ) 3 " A W F R O M AB O V E (E ) 6 " W A S T E D O W N (E ) 1 - 1 / 2 " V E N T U P (E ) 1 " I H W AW ( E ) G LG AW (E ) C O (E ) 3 " (E ) C O (E ) 2 " ( E ) A W (E ) 3 " (E ) 3 " (E ) 3 " (E ) C O (E ) 3 " (E ) 3 " L G (E ) 2 " (E ) 2 " L G R O (E ) 4 " WA S T E (E ) 4 " A C I D W A S T E FR O M A B O V E (E ) 3 / 4 " L G (E ) 1 " I C W (E ) 1 " (E ) 1 - 1 / 4 " L G LA (E ) 1 " I H W LG L G (E ) 1 " G G (E ) 1 - 1 / 4 " I H W (E ) 1 " I C W (E ) 3 / 4 " L G A W (E ) 1 / 2 " (E ) 1 " I H W (E ) 3 / 4 " L A LA (E ) 1 " I C W (E ) 3 " A W DO W N FR O M AB O V E R O (E ) F D 3" (E ) 3 " VE N T U P (E ) 4 " R D LE A D E R (E ) 2 " V E N T U P (E ) 1 1 / 2 " V E N T U P (E ) 4 " R D DR O P (E ) 4 " R D LE A D E R (E ) 4 " R D L E A D E R FR O M A B O V E (E ) 4 " W (E ) 4 " W FR O M A B O V E (E ) 1 - 1 / 2 " V E N T FR O M B E L O W L A I H W I C W I H W R LG IH W R IC W IH W I H W I C W L A L G L G I H W L A I C W I H W R (E ) A W D N T O B E L O W ME C H A N I C A L R M S L A B ( E ) R O R O (E ) R O RO (E ) 1 " L G 1" (E ) 3 / 4 " L A (E ) 1 - 1 / 2 " I C W (E ) 3 / 4 " I H W R (E ) 1 - 1 / 4 " I H W IH W R IH W IC W LG (E ) 3 / 4 " (E ) 1 " LA (E ) 3 " V E N T U P LG (E ) 1 " I H W (E ) 3 " (E ) 3 " VE N T R I S E R (E ) 1 - 1 / 4 " (E ) 1 - 1 / 4 " L G L G (E ) 3 / 4 " (E ) 1 - 1 / 4 " I C W (E ) 3 / 4 " L A (E ) 3 / 4 " L G R O (E ) 1 / 2 " (E ) 3 / 4 " I H W R 1" (E ) 1 - 1 / 4 " I H W (E ) 1 - 1 / 4 " I H W LG LA R O (E ) 3 " (E ) 1 / 2 " U P T O (E ) D R I N K I N G F O U N T A I N (E ) 2 " S A N I T A R Y WA S T E D O W N FR O M A B O V E (E ) D R I N K I N G FO U N T A I N (E ) 1 - 1 / 2 " D O W N (E ) 2 " S A N I T A R Y WA S T E D O W N . (E ) 4 " R D L E A D E R FR O M A B O V E (E ) 3 " A W FR O M A B O V E TO B E L O W (E ) D R I N K I N G FO U N T A I N (E ) 3 / 4 " D C W (E ) 3 / 4 " D C W I H W DC W D C W DC W D C W D C W (E ) 3 / 4 " D C W (E ) 3 / 4 " D C W DC W (E ) 3 / 4 " DC W D O W N (E ) 3 " W A S T E FR O M A B O V E (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 - 1 / 4 " (E ) 1 - 1 / 4 " (E ) 1 - 1 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " L A L G L G (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 " (E ) 3 / 4 " (E ) 1 - 1 / 4 " L G (E ) 3 / 4 " (E ) 1 - 1 / 2 " (E ) 3 " VE N T U P (E ) 3 / 4 " (E ) 1 / 2 " (E ) 3 / 4 " L G L A (E ) 1 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 1 " (E ) 3 / 4 " (E ) 1 " (E ) 1 - 1 / 4 " (E ) 1 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 " (E ) 2 " VE N T U P (E ) 1 / 2 " (E ) 1 / 2 " (E ) C O (E ) 1 / 2 " (E ) 1 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 1 " (E ) 1 - 1 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 1 / 2 " (E ) 1 - 1 / 4 " (E ) 1 " (E ) 3 / 4 " (E ) 1 - 1 / 4 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 1 - 1 / 4 " (E ) 1 / 2 " (E ) 1 " (E ) 3 / 4 " (E ) 2 " A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 PD 4 0 2 PD 4 0 2 PD 4 0 2 PD 4 0 2 1 11 1 1 11 1 2 22 2 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 11111 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PD101Level 01 Plumbing Demolition Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE # DESCRIPTION 1 11 1 NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.2 22 2 R E M O V E E X I S T I N G S I N K . P R O T E C T A S S O C I A T E D REMOVE EXISTING SINK. PROTECT ASSOCIATED REMOVE EXISTING SINK. PROTECT ASSOCIATED REMOVE EXISTING SINK. PROTECT ASSOCIATED WATER, WASTE AND VENT PIPING PREPARATORY WATER, WASTE AND VENT PIPING PREPARATORY WATER, WASTE AND VENT PIPING PREPARATORY WATER, WASTE AND VENT PIPING PREPARATORY FOR NEW SINK CONNECTION IN SAME LOCATION.FOR NEW SINK CONNECTION IN SAME LOCATION.FOR NEW SINK CONNECTION IN SAME LOCATION.FOR NEW SINK CONNECTION IN SAME LOCATION.SEE REMODEL PLAN PL101.SEE REMODEL PLAN PL101.SEE REMODEL PLAN PL101.SEE REMODEL PLAN PL101. SC A L E : SC A L E : SC A L E : SC A L E : PD 1 0 1 PD 1 0 1 PD 1 0 1 PD 1 0 1 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 1 P L U M B I N G D E M O L I T I O N P L A N 1 11 1 K-6716BANNO N C _ S I N K S C A S T I R O N A W IC W , L G IC W , I H W , L G , D C W (E ) 3 " V T R IC W , L G (E ) 3 " V T R IC W , L G IC W , L G IC W , L G W V IC W , I H W IH W , I C W (E ) C O (E ) 3 " AW RO , I C W , I H W A W (E ) 3 " LG A W IH W , I C W (E ) 3 " V T R IC W , I H W (E ) 3 " LG (E ) 3 " V T R (E ) 3 " V T R IC W , I H W , L G , D C W 3" (E ) 3 " V T R IH W IC W RO IC W , I H W , L G , D C W DC W , I C W , I H W , L G , R O DC W , I C W , I H W , L G LG , I C W L G , I C W V WLG , I C W L G , I C W (E ) 3 " W A S T E DO W N , ( E ) 3 " V T R (E ) C O (E ) 3 " V T R (E ) 3 " V T R (E ) 3 " LG AW (E ) C O (E ) F D (E ) F D LG (E ) 3 " V T R (E ) 1 - 1 / 2 " V E N T (E ) 3 " V T R (E ) 1 - 1 / 2 " V E N T (E ) 4 " V T R (E ) F D (E ) 2 " V E N T (E ) 3 " S O I L D O W N 3/4 " S T E A M 1/2 " C O N D . (E ) 3 " V T R (E ) 1 - 1 / 2 " V E N T (E ) 3 " V T R IC W , I H W , L G , D C W (E ) 4 " W A S T E (E ) 3 " V T R (E ) 3 " DO W N WC O IC W , I H W , L G , R O V WVW WC O WC O IC W DC W , I C W , I H W , L G , R O IC W , L G (E ) 3 " W WVWV WC O IC W LG IC W LGLG IC W WV WA S T E DO W N LGWC O (E ) 4 " 2"2" 3" IC W , L G 3" IC W , L G WV 3" VW IC W , L G , L A (E ) 3 " V T R 2" WC O IC W , I H W , L G , R O , D C W 3" 3" VW (E ) 3 " V T R 3"V T R 3" V W WC O (E ) 3 " V T R W V V (E ) 3 " V T R W (E ) 3 " V T R (E ) 3 " W A S T E DO W N (E ) 3 " V (E ) 3 " V T R VW (E ) 3 " V T R (E ) 3 " 2" V E N T FR O M B E L O W (E ) 3 " V T R (E ) 4 " R D LE A D E R FR O M AB O V E (E ) 4 " R D LE A D E R D O W N 4 " R D (E ) 3 " V T R (E ) 4 " R D LE A D E R (E ) 4 " R D LE A D E R D N . (E ) 3 " V T R (E ) 3 " V T R (E ) 2 " D N (E ) 3 " V T R (E ) 3 " (E ) 3 " V T R (E ) 3 " V T R (E ) 4 " R D L E A D E R FR O M A B O V E (E ) 4 " R D L E A D E R DO W N (E ) 2 " A V U P (E ) 3 " A W D O W N (E ) 3 " V T R IC W IH W LG LG IH W IC W LG IC W IH W IH W IC WRO (E ) 4 " R D LE A D E R FR O M AB O V E I C W L G L G I C W L G I C W I C W I H W R O R O I C W I H W (E ) 4 " R D LE A D E R FR O M AB O V E (E ) 3 " LA 2" V E N T FR O M B E L O W 3" V E N T FR O M B E L O W (E ) 3 " V E N T FR O M B E L O W 3" 2" 2" 2" 2" 3" 3" 3" 3" 2" 2" 2" 2" (E ) 3 " A W DO W N IC W , L G LA (E ) D R I N K I N G FO U N T A I N (E ) 1 / 2 " D C W (E ) R O DC W DC W D C W DC W DC W (E ) 4 " R D (E ) 3 " V T R 2" V E N T FR O M B E L O W 2" (E ) 3 " V T R FS (E ) 3 " W A S T E DO W N A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 PD 4 0 2 PD 4 0 2 PD 4 0 2 PD 4 0 2 2 22 2 PD 4 0 2 PD 4 0 2 PD 4 0 2 PD 4 0 2 3 33 3 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 11111 1 11 1 2 22 2 2 22 2 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PD102Level 02 Plumbing Demolition Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE # DESCRIPTION 1 11 1 NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES NO PLUMBING WORK IN THIS AREA. ALL FIXTURES AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT AND ASSOCIATED PIPING TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.2 22 2 F U M E H O O D T O B E R E L O C A T E D . S E E FUME HOOD TO BE RELOCATED. SEE FUME HOOD TO BE RELOCATED. SEE FUME HOOD TO BE RELOCATED. SEE MECHANICAL PLANS. DISCONNECT AND CAP MECHANICAL PLANS. DISCONNECT AND CAP MECHANICAL PLANS. DISCONNECT AND CAP MECHANICAL PLANS. DISCONNECT AND CAP ASSOCIATED WATER AND NATURAL GAS PIPING IN ASSOCIATED WATER AND NATURAL GAS PIPING IN ASSOCIATED WATER AND NATURAL GAS PIPING IN ASSOCIATED WATER AND NATURAL GAS PIPING IN CEILING SPACE PREPARATORY FOR NEW CEILING SPACE PREPARATORY FOR NEW CEILING SPACE PREPARATORY FOR NEW CEILING SPACE PREPARATORY FOR NEW CONNECTION. SEE REMODEL PLAN PL102. FIELD CONNECTION. SEE REMODEL PLAN PL102. FIELD CONNECTION. SEE REMODEL PLAN PL102. FIELD CONNECTION. SEE REMODEL PLAN PL102. FIELD VERIFY EXACT LOCATION.VERIFY EXACT LOCATION.VERIFY EXACT LOCATION.VERIFY EXACT LOCATION. SC A L E : SC A L E : SC A L E : SC A L E : PD 1 0 2 PD 1 0 2 PD 1 0 2 PD 1 0 2 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 2 P L U M B I N G D E M O L I T I O N P L A N 1 11 1 G G G G G G G G G DW (E ) F D (E)FD (E)FD (E)FD (E)FD (E)FD (E ) F D (E ) F D (E ) F S (E ) F S (E) 6"(E) 2"(E) 2"(E) 2" (E ) 2 " (E ) 2 " ( E ) W C O (E ) 2 " (E ) 2 " (E ) 2 " (E ) 8 " R D (E ) 4 " R D (E ) 4 " R D (E ) 6 " (E ) W C O (E ) 6 " (E ) S U M P PU M P (E ) F D (E ) 2 " (E ) 2 " (E ) 6 " (E ) 6 " (E ) W C O (E ) 2 " (E) 2"(E) 2" (E ) 2 " (E ) 2 " (E ) 2 " (E ) 4 " (E ) 4 " (E ) 4 " (E) 8" RD (E) 1/2" (E ) 4 " V E N T U P (E ) 2 " (E) 2" VENT UP (E) 2"(E) 1/2"(E) 1-1/2"(E) 1"(E) 1-1/4"(E) 1-1/4" (E ) 1 - 1 / 2 " (E) 1-1/2"(E) 1/2"(E) 1-1/4" (E ) 1 - 1 / 4 " (E ) 1 / 2 " (E) 1" (E ) 1 / 2 " (E) 1/2"(E) 1/2" (E ) 1 / 2 " (E ) 2 " V E N T U P (E ) 3 / 4 " (E ) 1 - 1 / 2 " (E ) 3 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 " (E ) 1 - 1 / 4 " (E ) 3 / 4 " (E ) 1 - 1 / 2 " (E ) 1 - 1 / 2 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " G A S FR O M A B O V E (E ) 1 - 1 / 4 " (E ) 3 " (E ) 1 / 2 " (E ) 3 / 4 " (E ) 2 " V E N T U P (E) 2" VENT UP(E)WH(E) 3/4" (E ) W H (E) 2"(E) 2" (E ) 2 " (E ) 2 " (E ) 2 " (E) 2-1/2"VENT UP (E) 2" (E ) W H (E ) 3 / 4 " A A A A A A A A A AA A B BB B C CC C D DD D 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 9 99 9 10 1010 10 11 1111 11 12 1212 12 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 2 22 2 2 22 2 2 22 2 2 22 2 3 33 3 11 1111 11 11 1111 11 11 1111 11 11 1111 1111111111 11 1111 11 11 1111 11 11 1111 11 11 1111 11 11 1111 11 11 1111 11 10 1010 10 10 1010 10 10 1010 10 10 1010 10 10 1010 10 10 1010 10 10 1010 10 10 1010 10 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 99999 9 99 9 3 33 3 3 33 3 3 33 3 5 55 55555 5 55 5 5 55 5 5 55 5 5 55 5 5 55 5 5 55 5 5 55 5 5 55 5 5 55 55555 5 55 55555 5 55 5 5 55 55555 5 55 5 5 55 5 5 55 55555 5 55 5 5 55 5 5 55 5 5 55 55555 6 66 6 6 66 6 6 66 6 6 66 612121212 CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P 9 99 9 CA P CA P CA P CA P CA P CA P CA P CA P CAP CAP CAP CAP CAP CAP CAP CAPCAPCAPCAPCAP CA P CA P CA P CA P CAP CAP CAP CAP CAP CAP CAP CAP CAP CAP CAP CAP CAP CAP CAP CAP5555 CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CAP CAP CAP CAP CA P CA P CA P CA P CA P CA P CA P CA P CAP CAP CAP CAP3333 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 999993 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PD401EnlargedLevel 00 Plumbing Demolition Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid Set SC A L E : SC A L E : SC A L E : SC A L E : PD 4 0 1 PD 4 0 1 PD 4 0 1 PD 4 0 1 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 0 P L U M B I N G D E M O L I T I O N P L A N 1 11 1 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 DR A W I N G N O T E S NOTE # DESCRIPTION 1 11 1 EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.2 22 2 EXISTING LAVATORY AND ASSOCIATED PIPING TO EXISTING LAVATORY AND ASSOCIATED PIPING TO EXISTING LAVATORY AND ASSOCIATED PIPING TO EXISTING LAVATORY AND ASSOCIATED PIPING TO REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.3 33 3 E X I S T I N G F L O O R D R A I N A N D / O R F L O O R S I N K T O EXISTING FLOOR DRAIN AND/OR FLOOR SINK TO EXISTING FLOOR DRAIN AND/OR FLOOR SINK TO EXISTING FLOOR DRAIN AND/OR FLOOR SINK TO REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.4 44 4 R E M O V E E X I S T I N G S E R V I C E S I N K A N D REMOVE EXISTING SERVICE SINK AND REMOVE EXISTING SERVICE SINK AND REMOVE EXISTING SERVICE SINK AND ASSOCIATED WATER PIPING BACK TO MAIN AND ASSOCIATED WATER PIPING BACK TO MAIN AND ASSOCIATED WATER PIPING BACK TO MAIN AND ASSOCIATED WATER PIPING BACK TO MAIN AND CAP. REMOVE VENT PIPING BACK TO MAIN AND CAP. REMOVE VENT PIPING BACK TO MAIN AND CAP. REMOVE VENT PIPING BACK TO MAIN AND CAP. REMOVE VENT PIPING BACK TO MAIN AND CAP. CAP AND ABANDON WASTE PIPING BELOW CAP. CAP AND ABANDON WASTE PIPING BELOW CAP. CAP AND ABANDON WASTE PIPING BELOW CAP. CAP AND ABANDON WASTE PIPING BELOW FLOOR.FLOOR.FLOOR.FLOOR.5 55 5 R E M O V E E X I S T I N G S I N K A N D A S S O C I A T E D W A T E R REMOVE EXISTING SINK AND ASSOCIATED WATER REMOVE EXISTING SINK AND ASSOCIATED WATER REMOVE EXISTING SINK AND ASSOCIATED WATER PIPING BACK TO MAIN AND CAP. REMOVE VENT PIPING BACK TO MAIN AND CAP. REMOVE VENT PIPING BACK TO MAIN AND CAP. REMOVE VENT PIPING BACK TO MAIN AND CAP. REMOVE VENT PIPING BACK TO MAIN AND CAP. CAP AND PIPING BACK TO MAIN AND CAP. CAP AND PIPING BACK TO MAIN AND CAP. CAP AND PIPING BACK TO MAIN AND CAP. CAP AND ABANDON WASTE PIPING BELOW FLOOR.ABANDON WASTE PIPING BELOW FLOOR.ABANDON WASTE PIPING BELOW FLOOR.ABANDON WASTE PIPING BELOW FLOOR.6 66 6 R E M O V E E X I S T I N G F L O O R D R A I N . C A P A N D REMOVE EXISTING FLOOR DRAIN. CAP AND REMOVE EXISTING FLOOR DRAIN. CAP AND REMOVE EXISTING FLOOR DRAIN. CAP AND ABANDON ASSOCIATED WASTE AND VENT PIPING ABANDON ASSOCIATED WASTE AND VENT PIPING ABANDON ASSOCIATED WASTE AND VENT PIPING ABANDON ASSOCIATED WASTE AND VENT PIPING BELOW FLOOR.BELOW FLOOR.BELOW FLOOR.BELOW FLOOR. N O T E # D E S C R I P T I O N 7 77 7 R E M O V E E X I S T I N G S E R V I C E S I N K A N D C A P RE M O V E E X I S T I N G S E R V I C E S I N K A N D C A P RE M O V E E X I S T I N G S E R V I C E S I N K A N D C A P RE M O V E E X I S T I N G S E R V I C E S I N K A N D C A P AS S O C I A T E D W A T E R P I P I N G P R E P A R A T O R Y F O R AS S O C I A T E D W A T E R P I P I N G P R E P A R A T O R Y F O R AS S O C I A T E D W A T E R P I P I N G P R E P A R A T O R Y F O R AS S O C I A T E D W A T E R P I P I N G P R E P A R A T O R Y F O R NE W C O N N E C T I O N . C A P V E N T P I P I N G NE W C O N N E C T I O N . C A P V E N T P I P I N G NE W C O N N E C T I O N . C A P V E N T P I P I N G NE W C O N N E C T I O N . C A P V E N T P I P I N G PR E P A R A T O R Y F O R N E W C O N N E C T I O N . R E M O V E PR E P A R A T O R Y F O R N E W C O N N E C T I O N . R E M O V E PR E P A R A T O R Y F O R N E W C O N N E C T I O N . R E M O V E PR E P A R A T O R Y F O R N E W C O N N E C T I O N . R E M O V E W A S T E P I P I N G A S S H O W N H A T C H E D . W A S T E P I P I N G A S S H O W N H A T C H E D . W A S T E P I P I N G A S S H O W N H A T C H E D . W A S T E P I P I N G A S S H O W N H A T C H E D . 8 88 8 E X I S T I N G S U M P P U M P T O R E M A I N . P R O T E C T EX I S T I N G S U M P P U M P T O R E M A I N . P R O T E C T EX I S T I N G S U M P P U M P T O R E M A I N . P R O T E C T EX I S T I N G S U M P P U M P T O R E M A I N . P R O T E C T D U R I N G C O N S T R U C T I O N . D U R I N G C O N S T R U C T I O N . D U R I N G C O N S T R U C T I O N . D U R I N G C O N S T R U C T I O N . 9 99 9 R E M O V E E X I S T I N G P I P I N G W H E R E S H O W N RE M O V E E X I S T I N G P I P I N G W H E R E S H O W N RE M O V E E X I S T I N G P I P I N G W H E R E S H O W N RE M O V E E X I S T I N G P I P I N G W H E R E S H O W N HA T C H E D . HA T C H E D . HA T C H E D . HA T C H E D . 10 1010 10 P R O T E C T E X I S T I N G G A S A N D / O R A I R P I P I N G PR O T E C T E X I S T I N G G A S A N D / O R A I R P I P I N G PR O T E C T E X I S T I N G G A S A N D / O R A I R P I P I N G PR O T E C T E X I S T I N G G A S A N D / O R A I R P I P I N G D U R I N G C O N S T R U C T I O N . D U R I N G C O N S T R U C T I O N . D U R I N G C O N S T R U C T I O N . D U R I N G C O N S T R U C T I O N . 11 1111 11 P R O T E C T E X I S T I N G R O O F D R A I N P I P I N G D U R I N G PR O T E C T E X I S T I N G R O O F D R A I N P I P I N G D U R I N G PR O T E C T E X I S T I N G R O O F D R A I N P I P I N G D U R I N G PR O T E C T E X I S T I N G R O O F D R A I N P I P I N G D U R I N G CO N S T R U C T I O N . CO N S T R U C T I O N . CO N S T R U C T I O N . CO N S T R U C T I O N . 12 1212 12 R E M O V E E X I S T I N G V E N T T H R O U G H R O O F . P A T C H RE M O V E E X I S T I N G V E N T T H R O U G H R O O F . P A T C H RE M O V E E X I S T I N G V E N T T H R O U G H R O O F . P A T C H RE M O V E E X I S T I N G V E N T T H R O U G H R O O F . P A T C H AN D S E A L R O O F C O M P L E T E . AN D S E A L R O O F C O M P L E T E . AN D S E A L R O O F C O M P L E T E . AN D S E A L R O O F C O M P L E T E . (E)4" (E ) F D (E ) 3 " (E ) 2 " VE N T U P (E ) C O LE A D E R D N . (E ) 4 " R D (E)FD (E ) F D K-6716BANNO N C _ S I N K S C A S T I R O N (E ) 3 " W A S T E DO W N , ( E ) 3 " V T R (E ) F D (E)FD (E ) 1 - 1 / 2 " V E N T (E ) 3 " V T R (E ) 1 - 1 / 2 " V E N T (E ) 4 " V T R (E ) F D (E ) 2 " V E N T (E)1-1/2" VENT (E)3"VTR (E ) 4 " R D LE A D E R D N . (E ) 3 " V T R (E ) 2 " V E N T FR O M B E L O W (E ) 2 " E EE E F FF F 4 44 4 5 55 5 1 11 1 2 22 2 3 33 3 6 66 6 7 77 7 8 88 8 8 88 8 8 88 8 8 88 8 2 22 2 2 22 2 2 22 2 2 22 2 6 66 6 6 66 6 6 66 63333 1 11 1 1 11 1 1 11 11111 1 11 1 3 33 3 6 66 6 1 11 111111111 E EE E F FF F 4 44 4 5 55 5 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 5 55 5 2 22 2 1 11 11111 1 11 1 3 33 3 3 33 3 1 11 1 1 11 11111 1 11 1 2 22 22222 5 55 5 5 55 5 5 55 5 6 66 6 6 66 6 6 66 6 10 1010 10 (E ) S E R V I C E S I N K 1 11 1 C CC C D DD D E EE E 2 22 2 3 33 3 9 99 9 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PD402EnlargedPlumbingDemolitionPlans22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid Set 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10DRAWING NOTES SC A L E : SC A L E : SC A L E : SC A L E : PD 4 0 2 PD 4 0 2 PD 4 0 2 PD 4 0 2 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 1 P L U M B I N G D E M O L I T I O N P L A N 1 11 1 NOTE # DESCRIPTION 1 11 1 REMOVE EXISTING WATER CLOSET AND/OR REMOVE EXISTING WATER CLOSET AND/OR REMOVE EXISTING WATER CLOSET AND/OR REMOVE EXISTING WATER CLOSET AND/OR URINAL. REMOVE ASSOCIATED WATER, WASTE URINAL. REMOVE ASSOCIATED WATER, WASTE URINAL. REMOVE ASSOCIATED WATER, WASTE URINAL. REMOVE ASSOCIATED WATER, WASTE AND VENT PIPING IN CHASE SPACE PREPARATORY AND VENT PIPING IN CHASE SPACE PREPARATORY AND VENT PIPING IN CHASE SPACE PREPARATORY AND VENT PIPING IN CHASE SPACE PREPARATORY FOR NEW. SEE REMODEL PLAN PL403.FOR NEW. SEE REMODEL PLAN PL403.FOR NEW. SEE REMODEL PLAN PL403.FOR NEW. SEE REMODEL PLAN PL403.2 22 2 R E M O V E E X I S T I N G L A V A T O R Y A N D A S S O C I A T E D REMOVE EXISTING LAVATORY AND ASSOCIATED REMOVE EXISTING LAVATORY AND ASSOCIATED REMOVE EXISTING LAVATORY AND ASSOCIATED WATER, WASTE AND VENT PIPING IN WALL WATER, WASTE AND VENT PIPING IN WALL WATER, WASTE AND VENT PIPING IN WALL WATER, WASTE AND VENT PIPING IN WALL PREPARATORY FOR NEW. SEE REMODEL PLAN PREPARATORY FOR NEW. SEE REMODEL PLAN PREPARATORY FOR NEW. SEE REMODEL PLAN PREPARATORY FOR NEW. SEE REMODEL PLAN PL403.PL403.PL403.PL403.3 33 3 E X I S T I N G F L O O R D R A I N T O R E M A I N . P R O T E C T EXISTING FLOOR DRAIN TO REMAIN. PROTECT EXISTING FLOOR DRAIN TO REMAIN. PROTECT EXISTING FLOOR DRAIN TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.4 44 4 E X I S T I N G S E R V I C E S I N K T O R E M A I N . P R O T E C T EXISTING SERVICE SINK TO REMAIN. PROTECT EXISTING SERVICE SINK TO REMAIN. PROTECT EXISTING SERVICE SINK TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.5 55 5 P R O T E C T E X I S T I N G V E N T T H R O U G H R O O F PROTECT EXISTING VENT THROUGH ROOF PROTECT EXISTING VENT THROUGH ROOF PROTECT EXISTING VENT THROUGH ROOF PREPARATORY FOR NEW CONNECTION. SEE PREPARATORY FOR NEW CONNECTION. SEE PREPARATORY FOR NEW CONNECTION. SEE PREPARATORY FOR NEW CONNECTION. SEE REMODEL PLAN PL403.REMODEL PLAN PL403.REMODEL PLAN PL403.REMODEL PLAN PL403.6 66 6 P R O T E C T E X I S T I N G V E N T R I S E D U R I N G PROTECT EXISTING VENT RISE DURING PROTECT EXISTING VENT RISE DURING PROTECT EXISTING VENT RISE DURING CONSTRUCTION.CONSTRUCTION.CONSTRUCTION.CONSTRUCTION.7 77 7 P R O T E C T E X I S T I N G 4 " R D L E A D E R D R O P D U R I N G PROTECT EXISTING 4" RD LEADER DROP DURING PROTECT EXISTING 4" RD LEADER DROP DURING PROTECT EXISTING 4" RD LEADER DROP DURING CONSTRUCTION.CONSTRUCTION.CONSTRUCTION.CONSTRUCTION.8 88 8 P R O T E C T E X I S T I N G W A S T E P I P I N G B E L O W F L O O R . PROTECT EXISTING WASTE PIPING BELOW FLOOR.PROTECT EXISTING WASTE PIPING BELOW FLOOR.PROTECT EXISTING WASTE PIPING BELOW FLOOR.9 99 9 R E M O V E E X I S T I N G L A B S I N K A N D A S S O C I A T E D REMOVE EXISTING LAB SINK AND ASSOCIATED REMOVE EXISTING LAB SINK AND ASSOCIATED REMOVE EXISTING LAB SINK AND ASSOCIATED WATER, WASTE AND VENT PIPING. REMOVE TO WATER, WASTE AND VENT PIPING. REMOVE TO WATER, WASTE AND VENT PIPING. REMOVE TO WATER, WASTE AND VENT PIPING. REMOVE TO CEILING SPACE AND BELOW FLOOR PREPARATORY CEILING SPACE AND BELOW FLOOR PREPARATORY CEILING SPACE AND BELOW FLOOR PREPARATORY CEILING SPACE AND BELOW FLOOR PREPARATORY FOR NEW CONNECTION. SEE REMODEL PLAN FOR NEW CONNECTION. SEE REMODEL PLAN FOR NEW CONNECTION. SEE REMODEL PLAN FOR NEW CONNECTION. SEE REMODEL PLAN PL404.PL404.PL404.PL404.10 1010 10 R E M O V E A N D P R O T E C T E X I S T I N G R E D U C E D REMOVE AND PROTECT EXISTING REDUCED REMOVE AND PROTECT EXISTING REDUCED REMOVE AND PROTECT EXISTING REDUCED PRESSURE PRINCIPLE BACK FLOW PREVENTER AND PRESSURE PRINCIPLE BACK FLOW PREVENTER AND PRESSURE PRINCIPLE BACK FLOW PREVENTER AND PRESSURE PRINCIPLE BACK FLOW PREVENTER AND ASSOCIATED PRV, VALVING, PIPING AND ASSOCIATED PRV, VALVING, PIPING AND ASSOCIATED PRV, VALVING, PIPING AND ASSOCIATED PRV, VALVING, PIPING AND CHEMICAL SOAP DISPENSER FOR REINSTALLATION CHEMICAL SOAP DISPENSER FOR REINSTALLATION CHEMICAL SOAP DISPENSER FOR REINSTALLATION CHEMICAL SOAP DISPENSER FOR REINSTALLATION IN NEW LOCATION. SEE REMODEL PLAN.IN NEW LOCATION. SEE REMODEL PLAN.IN NEW LOCATION. SEE REMODEL PLAN.IN NEW LOCATION. SEE REMODEL PLAN. SC A L E : SC A L E : SC A L E : SC A L E : PD 4 0 2 PD 4 0 2 PD 4 0 2 PD 4 0 2 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 2 P L U M B I N G D E M O L I T I O N P L A N 2 22 2 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 SC A L E : SC A L E : SC A L E : SC A L E : PD 4 0 2 PD 4 0 2 PD 4 0 2 PD 4 0 2 1/4 " = 1 ' 1/4 " = 1 ' 1/4 " = 1 ' 1/4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 2 P L U M B I N G D E M O L I T I O N P L A N 3 33 3 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 66 ME N ' S R M 64 WO M E N ' S R M O- C HA L L W A Y O- A VE S T I B U L E 69 ME C H A N I C A L R O O M 68 CU S T R M 59 CO M P U T E R L A B 59 D DA R K R O O M 59 E FI L M 59 C VE S T I B U L E 51 PH O T O S T U D I O 59 A EQ U I P / C H E C K O U T 59 B ST O R A G E 57 OF F I C E 55 OF F I C E 50 CL A S S R O O M 0- H VE S T I B U L E 51 B CH A N G I N G 52 C ST O R A G E 52 PH Y S I C S L A B 52 B AC O U S T I C S S T U D I O 52 A OP T I C S L A B 67 ME C H R M O- D EL E V A T O R 18 ST O R A G E 16 CU S T O F F I C E 14 CU S T O D I A L L A U N D R Y R M 12 ME C H R M 0- K EL E V A T O R 10 ME C H A N I C A L R M O- B ST A I R W E L L 63 ST O R A G E PL 4 0 1 PL 4 0 1 PL 4 0 1 PL 4 0 1 1 11 1 PL 4 0 2 PL 4 0 2 PL 4 0 2 PL 4 0 2 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PL100Level 00 Plumbing Remodel Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 SC A L E : SC A L E : SC A L E : SC A L E : PL 1 0 0 PL 1 0 0 PL 1 0 0 PL 1 0 0 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 0 P L U M B I N G R E M O D E L P L A N 1 11 1 NOTE # DESCRIPTION 1 11 1 NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION. A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 13 6 UN I S E X R M 13 4 ME N ' S R M 13 2 WO M E N ' S R M 1- J EL E V A T O R 13 8 BD F 1- V ST A I R W E L L 1- U HA L L W A Y 14 9 MIN E R O L O G Y L A B 14 5 LE C T U R E H A L L 14 3 PR E P / S T O R A G E R M 14 1 LA B O R A T O R Y 14 4 OF F I C E 14 2 OF F I C E 14 6 OF F I C E 14 8 OF F I C E 15 0 OF F I C E 15 0 A RE S O U R C E R O O M 15 4 SE I S M O G R A P H R O O M 15 6 PH Y S I C A L S C I E N C E D I S P L A Y R O O M 15 8 PH Y S I C A L G E O L O G Y R O O M 1- P ST A I R W E L L 16 0 WO M E N ' S T . R . 16 2 ME N ' S T . R . 16 4 RO C K L A B O R A T O R Y 16 7 HA Z . S T O R A G E 16 6 HA Z . S T O R A G E I- N HA L L W A Y 1- T HA L L W A Y 1- S ST A I R W E L L 17 1 AU T O T U T O R I A L R O O M 17 1 A ST O R A G E 17 5 OF F I C E 17 6 OF F I C E 17 9 LA B O R A T O R Y R M 17 2 LE C T U R E H A L L 13 3 A SH O P R M 17 2 A ST O R A G E 13 3 ST O R A G E R M 13 1 PH Y S I C S L E C T U R E H A L L 12 9 AD V A N C E D L A B R M I- F HA L L W A Y 12 8 AD V A N C E D L A B 12 6 A LA B S T O R A G E R M 12 6 AD V A N C E D L A B 12 7 LE C T U R E H A L L 10 7 PL A N R T A R I U M R M 10 5 PH Y S I C S C L A S S R O O M 1- H ST A I R W E L L I- G HA L L W A Y I- L HA L L W A Y I- D HA L L W A Y 18 0 OF F I C E 18 2 OF F I C E 18 4 OF F I C E 18 6 OF F I C E I- B ST A I R W E L L I- C ST A I R W E L L 11 0 OF F I C E 11 2 OF F I C E 11 4 OF F I C E 11 6 OF F I C E 11 8 OF F I C E 11 8 A OF F I C E PL 4 0 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 1 11 1 PL 4 0 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 2 22 2 1 11 1 P PP P----4 D 4D4D 4D 2 22 2 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PL101Level 01 Plumbing Remodel Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE # DESCRIPTION 1 11 1 NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.2 22 2 CONNECT NEW LAB SINK (P-4D) TO EXISTING CONNECT NEW LAB SINK (P-4D) TO EXISTING CONNECT NEW LAB SINK (P-4D) TO EXISTING CONNECT NEW LAB SINK (P-4D) TO EXISTING WATER, WASTE AND VENT PIPING.WATER, WASTE AND VENT PIPING.WATER, WASTE AND VENT PIPING.WATER, WASTE AND VENT PIPING. SC A L E : SC A L E : SC A L E : SC A L E : PL 1 0 1 PL 1 0 1 PL 1 0 1 PL 1 0 1 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 1 P L U M B I N G R E M O D E L P L A N 1 11 1 K-6716BANNO N C _ S I N K S C A S T I R O N A W IC W , L G IC W , I H W , L G , D C W (E ) 3 " V T R IC W , L G (E ) 3 " V T R IC W , L G IC W , L G IC W , L G W V IC W , I H W IH W , I C W (E ) C O (E ) 3 " AW RO , I C W , I H W A W (E ) 3 " LG A W IH W , I C W (E ) 3 " V T R IC W , I H W (E ) 3 " LG (E ) 3 " V T R (E ) 3 " V T R IC W , I H W , L G , D C W 3" (E ) 3 " V T R IH W IC W RO IC W , I H W , L G , D C W DC W , I C W , I H W , L G , R O DC W , I C W , I H W , L G LG , I C W L G , I C W V WLG , I C W L G , I C W (E ) 3 " W A S T E DO W N , ( E ) 3 " V T R (E ) C O (E ) 3 " V T R (E ) 3 " V T R (E ) 3 " LG AW (E ) C O (E ) F D (E ) F D LG (E ) 3 " V T R (E ) 1 - 1 / 2 " V E N T (E ) 3 " V T R (E ) 1 - 1 / 2 " V E N T (E ) 4 " V T R (E ) F D (E ) 2 " V E N T (E ) 3 " S O I L D O W N 3/4 " S T E A M 1/2 " C O N D . (E ) 3 " V T R (E ) 1 - 1 / 2 " V E N T (E ) 3 " V T R IC W , I H W , L G , D C W (E ) 4 " W A S T E (E ) 3 " V T R (E ) 3 " DO W N WC O IC W , I H W , L G , R O V WVW WC O WC O IC W DC W , I C W , I H W , L G , R O IC W , L G (E ) 3 " W WVWV WC O IC W LG IC W LGLG IC W WV WA S T E DO W N LGWC O (E ) 4 " 2"2" 3" IC W , L G 3" IC W , L G WV 3" VW IC W , L G , L A (E ) 3 " V T R 2" WC O IC W , I H W , L G , R O , D C W 3" 3" VW (E ) 3 " V T R 3"V T R 3" V W WC O (E ) 3 " V T R W V V (E ) 3 " V T R W (E ) 3 " V T R (E ) 3 " W A S T E DO W N (E ) 3 " V (E ) 3 " V T R VW (E ) 3 " V T R (E ) 3 " 2" V E N T FR O M B E L O W (E ) 3 " V T R (E ) 4 " R D LE A D E R FR O M AB O V E (E ) 4 " R D LE A D E R D O W N 4 " R D (E ) 3 " V T R (E ) 4 " R D LE A D E R (E ) 4 " R D LE A D E R D N . (E ) 3 " V T R (E ) 3 " V T R (E ) 2 " D N (E ) 3 " V T R (E ) 3 " (E ) 3 " V T R (E ) 3 " V T R (E ) 4 " R D L E A D E R FR O M A B O V E (E ) 4 " R D L E A D E R DO W N (E ) 2 " A V U P (E ) 3 " A W D O W N (E ) 3 " V T R IC W IH W LG LG IH W IC W LG IC W IH W IH W IC WRO (E ) 4 " R D LE A D E R FR O M AB O V E I C W L G L G I C W L G I C W I C W I H W R O R O I C W I H W (E ) 4 " R D LE A D E R FR O M AB O V E (E ) 3 " LA 2" V E N T FR O M B E L O W 3" V E N T FR O M B E L O W (E ) 3 " V E N T FR O M B E L O W 3" 2" 2" 2" 2" 3" 3" 3" 3" 2" 2" 2" 2" (E ) 3 " A W DO W N IC W , L G LA (E ) D R I N K I N G FO U N T A I N (E ) 1 / 2 " D C W (E ) R O DC W DC W D C W DC W DC W (E ) 4 " R D (E ) 3 " V T R 2" V E N T FR O M B E L O W 2" (E ) 3 " V T R FS (E ) 3 " W A S T E DO W N A AA A 1 11 1 B BB B C CC C D DD D E EE E F FF F G GG G H HH H J JJ J K KK K L LL L M M M M N NN N P PP P 2 22 2 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 8 88 8 27 0 CL A S S R O O M 26 8 CL A S S R O O M 26 6 ME N ' S R M 26 4 WO M E N ' S R M 26 2 CL A S S R O O M 26 0 CL A S S R O O M 2- M HA L L W A Y 26 7 CU S T R M 26 5 OF F I C E 26 3 OF F I C E 26 1 OF F I C E 25 9 OF F I C E 27 6 CL A S S R O O M 27 2 BI O - C H E M I S T R Y L A B 2- S HA L L W A Y 27 7 A ST O R A G E R M 27 7 CL A S S R O O M 25 5 CL A S S R O O M 2- V LO U N G E 25 8 ST O R A G E 25 3 OF F I C E 25 2 OF F I C E 25 0 OF F I C E 24 8 OF F I C E 24 6 OF F I C E 24 4 OF F I C E 23 0 SE C R E T A R Y / R E C E P T I O N R M 24 3 WO R K R O O M 2- L HA L L W A Y 24 2 OF F I C E 24 0 OF F I C E 23 8 OF F I C E 23 9 OF F I C E 23 7 OF F I C E 23 5 OF F I C E 23 3 OF F I C E 23 6 OF F I C E 23 4 OF F I C E 23 2 OF F I C E 2- K HA L L W A Y 2- J HA L L W A Y 2- D HA L L W A Y 21 4 CH E M I S T R Y L A B 21 3 CH E M I S T R Y S T O C K R M 2- H ST A I R W E L L 21 6 CU S T S T O R 2- G EL E V A T O R 22 0 WO M E N ' S R O O M 22 6 ME N ' S R O O M 22 8 CU S T R M 28 0 BD F R M 2- T ST A I R W E L L 27 9 CL A S S R O O M 22 9 CL A S S R O O M 20 3 A IN S T R U M E N T R M 21 3 A OF F I C E 20 3 CH E M I S T R Y L A B 21 0 CH E M I S T R Y L A B 29 9 CL A S S R O O M 29 7 CL A S S R O O M 28 1 CH E M I S T R Y P R E P R M 20 3 B IN S T R U M E N T R M 2- B HA L L W A Y 2- C ST A I R W E L L 2- A ST A I R W E L L 20 4 CH E M I S T R Y L A B 29 8 OF F I C E 29 6 OF F I C E 29 4 OF F I C E 29 2 OF F I C E 29 1 OF F I C E 29 0 OF F I C E 28 9 OF F I C E 28 7 SE C / R E C E P R M 28 6 OF F I C E 28 5 OF F I C E 28 2 A CH E M S T O C K R M 28 7 A WO R K R O O M 2- U HA L L W A Y 28 2 GE N E R A L C H E M L A B 2- F HA L L W A Y PL 4 0 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 3 33 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 4 44 4 PL 4 0 4 PL 4 0 4 PL 4 0 4 PL 4 0 4 1 11 1 PL 4 0 4 PL 4 0 4 PL 4 0 4 PL 4 0 4 2 22 2 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 2 22 2 2 22 2 3 33 3 2"2"2"2" 4 44 4 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PL102Level 02 Plumbing Remodel Plan22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 5 55 5 10 1010 10 10 1010 10 20 2020 20 NOTE # DESCRIPTION 1 11 1 NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT NO PLUMBNIG WORK IN THIS AREA. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.2 22 2 CONNECT NEW 2" WASTE TO EXISTING 3" WASTE CONNECT NEW 2" WASTE TO EXISTING 3" WASTE CONNECT NEW 2" WASTE TO EXISTING 3" WASTE CONNECT NEW 2" WASTE TO EXISTING 3" WASTE AT APPROXIMATELY THIS LOCATION. FIELD VERIFY AT APPROXIMATELY THIS LOCATION. FIELD VERIFY AT APPROXIMATELY THIS LOCATION. FIELD VERIFY AT APPROXIMATELY THIS LOCATION. FIELD VERIFY EXISTING SIZE AND LOCATION.EXISTING SIZE AND LOCATION.EXISTING SIZE AND LOCATION.EXISTING SIZE AND LOCATION.3 33 3 C O N N E C T N E W 2 " V E N T T O E X I S T I N G 2 " V E N T A T CONNECT NEW 2" VENT TO EXISTING 2" VENT AT CONNECT NEW 2" VENT TO EXISTING 2" VENT AT CONNECT NEW 2" VENT TO EXISTING 2" VENT AT APPROXIMATELY THIS LOCATION. FIELD VERIFY APPROXIMATELY THIS LOCATION. FIELD VERIFY APPROXIMATELY THIS LOCATION. FIELD VERIFY APPROXIMATELY THIS LOCATION. FIELD VERIFY EXISTING SIZE AND LOCATION.EXISTING SIZE AND LOCATION.EXISTING SIZE AND LOCATION.EXISTING SIZE AND LOCATION.4 44 4 C O N N E C T N E W 1 / 2 " N A T U R A L G A S A N D 1 / 2 " CONNECT NEW 1/2" NATURAL GAS AND 1/2"CONNECT NEW 1/2" NATURAL GAS AND 1/2"CONNECT NEW 1/2" NATURAL GAS AND 1/2"DOMESTIC COLD WATER TO EXISTING NATURAL DOMESTIC COLD WATER TO EXISTING NATURAL DOMESTIC COLD WATER TO EXISTING NATURAL DOMESTIC COLD WATER TO EXISTING NATURAL GAS AND DOMESTIC COLD WATER PIPING IN GAS AND DOMESTIC COLD WATER PIPING IN GAS AND DOMESTIC COLD WATER PIPING IN GAS AND DOMESTIC COLD WATER PIPING IN CEILING SPACE AT APPROXIMATELY THIS CEILING SPACE AT APPROXIMATELY THIS CEILING SPACE AT APPROXIMATELY THIS CEILING SPACE AT APPROXIMATELY THIS LOCATION. FIELD VERIFY EXISTING SIZE AND LOCATION. FIELD VERIFY EXISTING SIZE AND LOCATION. FIELD VERIFY EXISTING SIZE AND LOCATION. FIELD VERIFY EXISTING SIZE AND LOCATION.LOCATION.LOCATION.LOCATION. SC A L E : SC A L E : SC A L E : SC A L E : PL 1 0 2 PL 1 0 2 PL 1 0 2 PL 1 0 2 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' 1/ 8 " = 1 ' ----0"0"0"0" LE V E L 0 2 P L U M B I N G R E M O D E L P L A N 1 11 1 (E ) F D (E ) F D (E ) F S (E ) F S (E) 6"(E) 2"(E) 2"(E) 2" (E ) 2 " (E ) 2 " ( E ) W C O (E ) 2 " (E ) 2 " (E ) 2 " (E ) 8 " R D (E ) 4 " R D (E ) 4 " R D (E ) 6 " (E ) W C O (E ) 6 " (E ) S U M P PU M P (E ) F D (E ) 2 " (E ) 2 " (E ) 6 " (E ) 6 " (E) 2"(E) 2" (E ) 2 " (E ) 2 " (E ) 2 " (E ) 4 " (E ) 4 " (E ) 4 " (E) 8" RD (E ) 4 " V E N T U P (E ) 2 " (E) 2" VENT UP (E) 2" (E ) 2 " V E N T U P (E) 2-1/2"VENT UP (E) 2"(E)FD K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4989-TFRESHM ANC_URINALSVITREO US CHINA K-4989-TFRESHM ANC_URINALSVITREO US CHINA K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-2196-8PENNING TO NLAVATO RYVITREO US CHINA K-2196-8PENNING TO NLAVATO RYVITREO US CHINA K-2196-8PENNING TO NLAVATO RYVITREO US CHINA K-2196-8PENNING TO NLAVATO RYVITREO US CHINA K-2196-8PENNING TO NLAVATO RYVITREO US CHINA A AA A B BB B C CC C D DD D E EE E 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 68 CU S T R M 67 ME C H R M O- D EL E V A T O R 69 ME C H A N I C A L R O O M 59 CO M P U T E R L A B 59 D DA R K R O O M 59 C VE S T I B U L E 59 E FI L M 51 A ST O R A G E 51 B CH A N G I N G 0-HVESTIBULE 51 PH O T O S T U D I O 59 A EQ U I P / C H E C K O U T 59 B ST O R A G E 57 OF F I C E 55 OF F I C E 50CLASSROOM52CSTORAGE52PHYSICS LAB 52 B AC O U S T I C S S T U D I O 52 A OP T I C S L A B O- C HA L L W A Y O- A VE S T I B U L E 64 WO M E N ' S R M 66 ME N ' S R M 63 ST O R A G E O- B ST A I R W E L L 1 11 1 2 22 2 3 33 3 5 55 5 6 66 67777 8 88 8 9 99 9 4 44 4 3 33 3 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 2 22 2 2 22 2 2 22 2 2 22 2 6 66 6 3 33 3 3 33 3 3 33 3 P PP P----4 B 4B4B 4B P PP P----4 A 4A4A 4A P PP P----4D 4D4D 4D 6 66 6 6 66 6 6 66 6 6 66 6 6 66 6 6 66 6 6 66 6 6 66 6666666666666666666666666666666666666666666666666 6 66 6 6 66 6 6 66 6 6 66 6 7 77 7 7 77 7 7 77 7 7 77 7 7 77 7 7 77 7 2"2"2"2" 3"3"3"3" 6 66 6 9 99 9 2"2"2"2" 2"2"2"2" 2"2"2"2" 9 99 9 8 88 8 2"2"2"2" 2"2"2"2" 9 99 9 8 88 83333PPPP----7 77 7 6 66 6 2"2"2"2" WC O WC O WC O WC O P PP P----4 C 4C4C 4C FD FDFD FD - ---1 11 1 FD FDFD FD - ---1 11 1 2"2"2"2" 2"2"2"2" P PP P----5 55 5 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PL401EnlargedLevel 00 Plumbing Remodel Plan - W a s t e & Vent22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid Set 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 DR A W I N G N O T E S SC A L E : SC A L E : SC A L E : SC A L E : PL 4 0 1 PL 4 0 1 PL 4 0 1 PL 4 0 1 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 0 P L U M B I N G R E M O D E L P L A N - WA S T E & V E N T 1 11 1 NOTE # DESCRIPTION 1 11 1 EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.2 22 2 EXISTING LAVATORY TO REMAIN. PROTECT EXISTING LAVATORY TO REMAIN. PROTECT EXISTING LAVATORY TO REMAIN. PROTECT EXISTING LAVATORY TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.3 33 3 E X I S T I N G F L O O R D R A I N A N D / O R F L O O R S I N K T O EXISTING FLOOR DRAIN AND/OR FLOOR SINK TO EXISTING FLOOR DRAIN AND/OR FLOOR SINK TO EXISTING FLOOR DRAIN AND/OR FLOOR SINK TO REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.4 44 4 C O N N E C T N E W 3 " W A S T E T O E X I S T I N G W A S T E A T CONNECT NEW 3" WASTE TO EXISTING WASTE AT CONNECT NEW 3" WASTE TO EXISTING WASTE AT CONNECT NEW 3" WASTE TO EXISTING WASTE AT APPROXIMATELY THIS LOCATION. FIELD VERIFY APPROXIMATELY THIS LOCATION. FIELD VERIFY APPROXIMATELY THIS LOCATION. FIELD VERIFY APPROXIMATELY THIS LOCATION. FIELD VERIFY EXACT LOCATION.EXACT LOCATION.EXACT LOCATION.EXACT LOCATION.5 55 5 E X I S T I N G S U M P P U M P T O R E M A I N . P R O T E C T EXISTING SUMP PUMP TO REMAIN. PROTECT EXISTING SUMP PUMP TO REMAIN. PROTECT EXISTING SUMP PUMP TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.6 66 6 C A P A N D A B A N D O N E X I S T I N G W A S T E B E L O W CAP AND ABANDON EXISTING WASTE BELOW CAP AND ABANDON EXISTING WASTE BELOW CAP AND ABANDON EXISTING WASTE BELOW FLOOR.FLOOR.FLOOR.FLOOR. N O T E # D E S C R I P T I O N 7 77 7 C A P A N D A B A N D O N E X I S T I N G V E N T P I P I N G I N CA P A N D A B A N D O N E X I S T I N G V E N T P I P I N G I N CA P A N D A B A N D O N E X I S T I N G V E N T P I P I N G I N CA P A N D A B A N D O N E X I S T I N G V E N T P I P I N G I N CE I L I N G S P A C E . CE I L I N G S P A C E . CE I L I N G S P A C E . CE I L I N G S P A C E . 8 88 8 C O N N E C T N E W 2 " W A S T E T O E X I S T I N G W A S T E A T CO N N E C T N E W 2 " W A S T E T O E X I S T I N G W A S T E A T CO N N E C T N E W 2 " W A S T E T O E X I S T I N G W A S T E A T CO N N E C T N E W 2 " W A S T E T O E X I S T I N G W A S T E A T AP P R O X I M A T E L Y T H I S L O C A T I O N . F I E L D V E R I F Y AP P R O X I M A T E L Y T H I S L O C A T I O N . F I E L D V E R I F Y AP P R O X I M A T E L Y T H I S L O C A T I O N . F I E L D V E R I F Y AP P R O X I M A T E L Y T H I S L O C A T I O N . F I E L D V E R I F Y EX A C T L O C A T I O N . EX A C T L O C A T I O N . EX A C T L O C A T I O N . EX A C T L O C A T I O N . 9 99 9 C O N N E C T N E W 2 " V E N T T O E X I S T I N G V E N T P I P I N G CO N N E C T N E W 2 " V E N T T O E X I S T I N G V E N T P I P I N G CO N N E C T N E W 2 " V E N T T O E X I S T I N G V E N T P I P I N G CO N N E C T N E W 2 " V E N T T O E X I S T I N G V E N T P I P I N G AT A P P R O X I M A T E L Y T H I S L O C A T I O N . F I E L D V E R I F Y AT A P P R O X I M A T E L Y T H I S L O C A T I O N . F I E L D V E R I F Y AT A P P R O X I M A T E L Y T H I S L O C A T I O N . F I E L D V E R I F Y AT A P P R O X I M A T E L Y T H I S L O C A T I O N . F I E L D V E R I F Y EX A C T L O C A T I O N . EX A C T L O C A T I O N . EX A C T L O C A T I O N . EX A C T L O C A T I O N . G G G G G G G G G DW (E) 1/2"(E) 1-1/2"(E) 1" (E ) 1 - 1 / 2 " (E) 1-1/2"(E) 1-1/4" (E ) 3 / 4 " (E ) 1 - 1 / 2 " (E ) 3 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 " (E ) 1 - 1 / 4 " (E ) 3 / 4 " (E ) 1 - 1 / 2 " (E ) 1 - 1 / 2 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " (E ) 3 / 4 " G A S FR O M A B O V E (E ) 1 - 1 / 4 " (E ) 3 " (E)WH(E) 3/4" (E ) W H (E ) W H (E ) 3 / 4 " (E ) 3 / 4 " K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-4989-TFRESHM ANC_URINALSVITREO US CHINA K-4989-TFRESHM ANC_URINALSVITREO US CHINA K-4330KING S T O N C _ T O I L E T S V I T R E O U S C H I N A K-2196-8PENNING TO NLAVATO RYVITREO US CHINA K-2196-8PENNING TO NLAVATO RYVITREO US CHINA K-2196-8PENNING TO NLAVATO RYVITREO US CHINA K-2196-8PENNING TO NLAVATO RYVITREO US CHINA K-2196-8PENNING TO NLAVATO RYVITREO US CHINA A A A A A A A A A AA A B BB B C CC C D DD D E EE E 3 33 3 4 44 4 5 55 5 6 66 6 7 77 7 68 CU S T R M 67 ME C H R M O- D EL E V A T O R 69 ME C H A N I C A L R O O M 59 CO M P U T E R L A B 59 D DA R K R O O M 59 C VE S T I B U L E 59 E FI L M 51 A ST O R A G E 51 B CH A N G I N G 0- H VE S T I B U L E 51 PH O T O S T U D I O 59 A EQ U I P / C H E C K O U T 59 B ST O R A G E 57 OF F I C E 55 OF F I C E 50CLASSROOM52CSTORAGE52PHYSICS LAB 52 B AC O U S T I C S S T U D I O 52 A OP T I C S L A B O- C HA L L W A Y O- A VE S T I B U L E 64 WO M E N ' S R M 66 ME N ' S R M 63 ST O R A G E O- B ST A I R W E L L 1 11 1 2 22 2 3 33 3 4 44 4 5 55 5 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 1 11 1 2 22 2 2 22 222222222 CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CAP CAP CAP CAP CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CA P CAP CAP CAP CAP P PP P----4 B 4B4B 4B P PP P----4 A 4A4A 4A P PP P----4D 4D4D 4D 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 3 33 3 1"1"1"1"6 66 6 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 3 33 3 CA P CA P CA P CA P P PP P----7 77 7 P PP P----6 66 6MVMVMVMV22221"1"1"1" P PP P----6 66 6 HB HBHB HB----1 11 1 HB HBHB HB----2 22 2 1/2" DI 1/2" DI 1/2" DI 1/2" DI DI DI DI DI DI DI DI DI1/2"1/2"1/2"1/2" DI DIDI DI DI DIDI DI DI DIDI DI DI DIDI DI 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " D I 1/ 2 " D I 1/ 2 " D I 1/ 2 " D I 7 77 7 8 88 8 P PP P----4 C 4C4C 4C D I D I D I D I 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 3 33 3 8 88 8 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9 9 99 9999999999999 P PP P----5 55 5 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PL402EnlargedLevel 00 Plumbing Remodel Plan - W a t e r & G a s 22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid Set 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 DR A W I N G N O T E S SC A L E : SC A L E : SC A L E : SC A L E : PL 4 0 2 PL 4 0 2 PL 4 0 2 PL 4 0 2 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 0 P L U M B I N G R E M O D E L P L A N - WA T E R & G A S 1 11 1 NOTE # DESCRIPTION 1 11 1 EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO EXISTING WATER CLOSET AND/OR URINAL TO REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.REMAIN. PROTECT DURING CONSTRUCTION.2 22 2 EXISTING LAVATORY TO REMAIN. PROTECT EXISTING LAVATORY TO REMAIN. PROTECT EXISTING LAVATORY TO REMAIN. PROTECT EXISTING LAVATORY TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.3 33 3 C O N N E C T N E W 1 / 2 " D C W A N D 1 / 2 " D H W T O CONNECT NEW 1/2" DCW AND 1/2" DHW TO CONNECT NEW 1/2" DCW AND 1/2" DHW TO CONNECT NEW 1/2" DCW AND 1/2" DHW TO EXISTING DCW AND DHW AT APPROXIMATELY THIS EXISTING DCW AND DHW AT APPROXIMATELY THIS EXISTING DCW AND DHW AT APPROXIMATELY THIS EXISTING DCW AND DHW AT APPROXIMATELY THIS LOCATION. FIELD VERIFY EXACT LOCATION.LOCATION. FIELD VERIFY EXACT LOCATION.LOCATION. FIELD VERIFY EXACT LOCATION.LOCATION. FIELD VERIFY EXACT LOCATION.4 44 4 M O U N T H O T A N D C O L D H O S E B I B B S O N W A L L MOUNT HOT AND COLD HOSE BIBBS ON WALL MOUNT HOT AND COLD HOSE BIBBS ON WALL MOUNT HOT AND COLD HOSE BIBBS ON WALL UNDER LAB SINK.UNDER LAB SINK.UNDER LAB SINK.UNDER LAB SINK.5 55 5 R E L O C A T E E X I S T I N G R E D U C E D P R E S S U R E RELOCATE EXISTING REDUCED PRESSURE RELOCATE EXISTING REDUCED PRESSURE RELOCATE EXISTING REDUCED PRESSURE PRINCIPLE BACK FLOW PREVENTER AND PRINCIPLE BACK FLOW PREVENTER AND PRINCIPLE BACK FLOW PREVENTER AND PRINCIPLE BACK FLOW PREVENTER AND ASSOCIATED PRV, VALVING, PIPING AND ASSOCIATED PRV, VALVING, PIPING AND ASSOCIATED PRV, VALVING, PIPING AND ASSOCIATED PRV, VALVING, PIPING AND CHEMICAL SOAP DISPENSER TO THIS LOCATION.CHEMICAL SOAP DISPENSER TO THIS LOCATION.CHEMICAL SOAP DISPENSER TO THIS LOCATION.CHEMICAL SOAP DISPENSER TO THIS LOCATION.CONNECT TO NEW WATER PIPING AS REQUIRED.CONNECT TO NEW WATER PIPING AS REQUIRED.CONNECT TO NEW WATER PIPING AS REQUIRED.CONNECT TO NEW WATER PIPING AS REQUIRED.SEE DETAIL 8/PL501.SEE DETAIL 8/PL501.SEE DETAIL 8/PL501.SEE DETAIL 8/PL501. N O T E # D E S C R I P T I O N 6 66 6 C O N N E C T N E W 1 " D C W A N D 1 " D H W T O E X I S T I N G CO N N E C T N E W 1 " D C W A N D 1 " D H W T O E X I S T I N G CO N N E C T N E W 1 " D C W A N D 1 " D H W T O E X I S T I N G CO N N E C T N E W 1 " D C W A N D 1 " D H W T O E X I S T I N G D C W A N D D H W A T A P P R O X I M A T E L Y T H I S D C W A N D D H W A T A P P R O X I M A T E L Y T H I S D C W A N D D H W A T A P P R O X I M A T E L Y T H I S D C W A N D D H W A T A P P R O X I M A T E L Y T H I S LO C A T I O N . F I E L D V E R I F Y E X A C T L O C A T I O N . LO C A T I O N . F I E L D V E R I F Y E X A C T L O C A T I O N . LO C A T I O N . F I E L D V E R I F Y E X A C T L O C A T I O N . LO C A T I O N . F I E L D V E R I F Y E X A C T L O C A T I O N . 7 77 7 D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N F R O M L E V E L D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N F R O M L E V E L D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N F R O M L E V E L D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N F R O M L E V E L AB O V E A N D R O U T E A S S H O W N . AB O V E A N D R O U T E A S S H O W N . AB O V E A N D R O U T E A S S H O W N . AB O V E A N D R O U T E A S S H O W N . 8 88 8 D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N I N W A L L A N D D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N I N W A L L A N D D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N I N W A L L A N D D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N I N W A L L A N D CO N N E C T T O D E I O N I Z E D W A T E R S P O U T . CO N N E C T T O D E I O N I Z E D W A T E R S P O U T . CO N N E C T T O D E I O N I Z E D W A T E R S P O U T . CO N N E C T T O D E I O N I Z E D W A T E R S P O U T . 9 99 9 D E I O N I Z E D W A T E R P I P I N G A N D A S S O C I A T E D D E I O N I Z E D W A T E R P I P I N G A N D A S S O C I A T E D D E I O N I Z E D W A T E R P I P I N G A N D A S S O C I A T E D D E I O N I Z E D W A T E R P I P I N G A N D A S S O C I A T E D FA U C E T A N D V A L V I N G A R E P A R T O F A D D . FA U C E T A N D V A L V I N G A R E P A R T O F A D D . FA U C E T A N D V A L V I N G A R E P A R T O F A D D . FA U C E T A N D V A L V I N G A R E P A R T O F A D D . AL T E R N A T E # 5 . AL T E R N A T E # 5 . AL T E R N A T E # 5 . AL T E R N A T E # 5 . (E)4" (E ) F D (E ) 3 " (E ) 2 " VE N T U P (E ) C O LE A D E R D N . (E ) 4 " R D K-6716BANNO N C _ S I N K S C A S T I R O N (E ) 3 " W A S T E DO W N , ( E ) 3 " V T R (E ) F D (E ) F D (E ) 3 " V T R (E ) 4 " V T R (E ) F D (E ) 3 " V T R (E ) 4 " R D LE A D E R D N . (E ) 3 " V T R (E ) 2 " V E N T FR O M B E L O W (E ) 2 " K-6716BANNO N C _ S I N K S C A S T I R O N E EE E F FF F 4 44 4 5 55 5 13 6 UN I S E X R M 13 4 ME N ' S R M 132WOMEN'S RM 1 11 1 4 44 4 3 33 3 5 55 5 P PP P----3 33 3 P PP P----1 B 1B1B 1B P PP P----3 33 3 P PP P----3 33 3 P PP P----2 A 2A2A 2A P PP P----2 A 2A2A 2A P PP P----2 B 2B2B 2B P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----3 33 3PPPP----3 33 3 5 55 5 5 55 5 4 44 4 5 55 5 3 33 3 3 33 3 5 55 5 3 33 3 5 55 53333 E EE E F FF F 4 44 4 5 55 5 13 6 UN I S E X R M 13 4 ME N ' S R M 132WOMEN'S RM 6 66 6 P PP P----3 33 3 P PP P----1 B 1B1B 1B P PP P----3 33 3 P PP P----3 33 3 P PP P----2 A 2A2A 2A P PP P----2 A 2A2A 2A P PP P----2 B 2B2B 2B P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----3 33 3PPPP----3 33 3 6 66 6 6 66 6 WH A WH A WH A WH A - ---B BB B 1 11 1----1 / 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1 11 1----1 / 2 " 1/ 2 " 1/ 2 " 1/ 2 " 10 1010 10 9 99 9 6 66 6 10 1010 10 2"2"2"2" 2"2"2"2" WH A WH A WH A WH A - ---C CC C 9 99 9 E EE E F FF F 4 44 4 5 55 5 22 8 CU S T R M 22 6 ME N ' S R O O M 22 0 WO M E N ' S R O O M 2- G EL E V A T O R 1 11 1 4 44 4 P PP P----3 33 3 P PP P----3 33 3 P PP P----2 B 2B2B 2B P PP P----2 A 2A2A 2A P PP P----2 A 2A2A 2A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----3 33 3 P PP P----3 33 3 NE W 2 " V E N T NE W 2 " V E N T NE W 2 " V E N T NE W 2 " V E N T FR O M B E L O W FR O M B E L O W FR O M B E L O W FR O M B E L O W NE W 2 " V E N T NE W 2 " V E N T NE W 2 " V E N T NE W 2 " V E N T FR O M B E L O W FR O M B E L O W FR O M B E L O W FR O M B E L O W NE W 2 " V E N T NE W 2 " V E N T NE W 2 " V E N T NE W 2 " V E N T FR O M B E L O W FR O M B E L O W FR O M B E L O W FR O M B E L O W 2 22 2 NE W 2 " V E N T NE W 2 " V E N T NE W 2 " V E N T NE W 2 " V E N T FR O M B E L O W FR O M B E L O W FR O M B E L O W FR O M B E L O W 2 22 2 2 22 2 2 22 2 11 1111 11 (E ) S E R V I C E SI N K E EE E F FF F 4 44 4 5 55 5 22 8 CU S T R M 22 6 ME N ' S R O O M 22 0 WO M E N ' S R O O M 2- G EL E V A T O R P PP P----3 33 3 P PP P----3 33 3 P PP P----2 B 2B2B 2B P PP P----2 A 2A2A 2A P PP P----2 A 2A2A 2A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----1 A 1A1A 1A P PP P----3 33 3 P PP P----3 33 3 7 77 7 8 88 8 8 88 8 8 88 8 7 77 7 11 1111 11 (E ) S E R V I C E SI N K 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PL403EnlargedPlumbingRemodelPlans22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid Set0000 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10DRAWING NOTES NOTE # DESCRIPTION 1 11 1 EXISTING ROOF DRAIN TO REMAIN. PROTECT EXISTING ROOF DRAIN TO REMAIN. PROTECT EXISTING ROOF DRAIN TO REMAIN. PROTECT EXISTING ROOF DRAIN TO REMAIN. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.2 22 2 CONNECT NEW 2" VENT TO EXISTING VENT CONNECT NEW 2" VENT TO EXISTING VENT CONNECT NEW 2" VENT TO EXISTING VENT CONNECT NEW 2" VENT TO EXISTING VENT THROUGH ROOF AT APPROXIMATELY THIS THROUGH ROOF AT APPROXIMATELY THIS THROUGH ROOF AT APPROXIMATELY THIS THROUGH ROOF AT APPROXIMATELY THIS LOCATION. FIELD VERIFY EXACT LOCATION.LOCATION. FIELD VERIFY EXACT LOCATION.LOCATION. FIELD VERIFY EXACT LOCATION.LOCATION. FIELD VERIFY EXACT LOCATION.3 33 3 R I S E 2 " V E N T U P T O L E V E L A B O V E . RISE 2" VENT UP TO LEVEL ABOVE.RISE 2" VENT UP TO LEVEL ABOVE.RISE 2" VENT UP TO LEVEL ABOVE.4 44 4 P R O T E C T E X I S T I N G V E N T R I S E D U R I N G PROTECT EXISTING VENT RISE DURING PROTECT EXISTING VENT RISE DURING PROTECT EXISTING VENT RISE DURING CONSTRUCTION.CONSTRUCTION.CONSTRUCTION.CONSTRUCTION.5 55 5 C O N N E C T N E W W A S T E T O E X I S T I N G W A S T E B E L O W CONNECT NEW WASTE TO EXISTING WASTE BELOW CONNECT NEW WASTE TO EXISTING WASTE BELOW CONNECT NEW WASTE TO EXISTING WASTE BELOW FLOOR AT APPROXIMATELY THIS LOCATION. FIELD FLOOR AT APPROXIMATELY THIS LOCATION. FIELD FLOOR AT APPROXIMATELY THIS LOCATION. FIELD FLOOR AT APPROXIMATELY THIS LOCATION. FIELD VERIFY EXACT LOCATION.VERIFY EXACT LOCATION.VERIFY EXACT LOCATION.VERIFY EXACT LOCATION.6 66 6 C O N N E C T N E W D C W A N D / O R D H W P I P I N G T O CONNECT NEW DCW AND/OR DHW PIPING TO CONNECT NEW DCW AND/OR DHW PIPING TO CONNECT NEW DCW AND/OR DHW PIPING TO EXISTING IN CEILING SPACE AND ROUTE TO NEW EXISTING IN CEILING SPACE AND ROUTE TO NEW EXISTING IN CEILING SPACE AND ROUTE TO NEW EXISTING IN CEILING SPACE AND ROUTE TO NEW FIXTURE. FIELD VERIFY EXACT LOCATION.FIXTURE. FIELD VERIFY EXACT LOCATION.FIXTURE. FIELD VERIFY EXACT LOCATION.FIXTURE. FIELD VERIFY EXACT LOCATION.7 77 7 R I S E N E W D C W A N D D H W P I P I N G U P F R O M L E V E L RISE NEW DCW AND DHW PIPING UP FROM LEVEL RISE NEW DCW AND DHW PIPING UP FROM LEVEL RISE NEW DCW AND DHW PIPING UP FROM LEVEL BELOW AND CONNECT TO FIXTURE.BELOW AND CONNECT TO FIXTURE.BELOW AND CONNECT TO FIXTURE.BELOW AND CONNECT TO FIXTURE.8 88 8 R I S E N E W D C W P I P I N G U P F R O M L E V E L B E L O W RISE NEW DCW PIPING UP FROM LEVEL BELOW RISE NEW DCW PIPING UP FROM LEVEL BELOW RISE NEW DCW PIPING UP FROM LEVEL BELOW AND CONNECT TO FIXTURE.AND CONNECT TO FIXTURE.AND CONNECT TO FIXTURE.AND CONNECT TO FIXTURE.9 99 9 S E E A R C H I T E C T U R A L P L A N F O R W A T E R H A M M E R SEE ARCHITECTURAL PLAN FOR WATER HAMMER SEE ARCHITECTURAL PLAN FOR WATER HAMMER SEE ARCHITECTURAL PLAN FOR WATER HAMMER ARRESTOR ACCESS DOOR IN WALL.ARRESTOR ACCESS DOOR IN WALL.ARRESTOR ACCESS DOOR IN WALL.ARRESTOR ACCESS DOOR IN WALL.10 1010 10 C O N N E C T N E W D C W P I P I N G T O E X I S T I N G D C W I N CONNECT NEW DCW PIPING TO EXISTING DCW IN CONNECT NEW DCW PIPING TO EXISTING DCW IN CONNECT NEW DCW PIPING TO EXISTING DCW IN CHASE SPACE. FIELD VERIFY EXACT LOCATION.CHASE SPACE. FIELD VERIFY EXACT LOCATION.CHASE SPACE. FIELD VERIFY EXACT LOCATION.CHASE SPACE. FIELD VERIFY EXACT LOCATION.11 1111 11 N O P L U M B I N G W O R K I N T H I S A R E A . P R O T E C T NO PLUMBING WORK IN THIS AREA. PROTECT NO PLUMBING WORK IN THIS AREA. PROTECT NO PLUMBING WORK IN THIS AREA. PROTECT DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION.DURING CONSTRUCTION. SC A L E : SC A L E : SC A L E : SC A L E : PL 4 0 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 1 P L U M B I N G R E M O D E L P L A N -WASTE & VENT 1 11 1 SC A L E : SC A L E : SC A L E : SC A L E : PL 4 0 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 1 P L U M B I N G R E M O D E L P L A N -WATER 2 22 2 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 SC A L E : SC A L E : SC A L E : SC A L E : PL 4 0 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 1/4 " = 1 ' 1/4 " = 1 ' 1/4 " = 1 ' 1/4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 2 P L U M B I N G R E M O D E L P L A N - WA S T E & V E N T 3 33 3 SC A L E : SC A L E : SC A L E : SC A L E : PL 4 0 3 PL 4 0 3 PL 4 0 3 PL 4 0 3 1/4 " = 1 ' 1/4 " = 1 ' 1/4 " = 1 ' 1/4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 2 P L U M B I N G R E M O D E L P L A N - WA T E R 4 44 4 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 1 11 1 C CC C D DD D E EE E 2 22 2 3 33 3 27 2 BI O - C H E M I S T R Y L A B P PP P----4 D 4D4D 4D P PP P----4 B 4B4B 4B P PP P----7 77 7 FD FDFD FD - ---1 11 12"2"2"2" 2"2"2"2" 2"2"2"2" 2"2"2"2" 2"2"2"2" 2"2"2"2" 2"2"2"2" 1 11 1 1 11 1 1 11 1 1 11 1 C CC C D DD D E EE E 2 22 2 3 33 3 27 2 BI O - C H E M I S T R Y L A B P PP P----4 D 4D4D 4D P PP P----6 66 6 MV MVMV MV 2 22 2 1"1"1"1" P PP P----4 B 4B4B 4B P PP P----6 66 6 P PP P----7 77 7 2 22 2 3 33 3 4 44 4 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " DI DIDI DI D I D I D I D I 1"1"1"1" 1"1"1"1" D I D I D I D I D I D I D I D I 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 4 44 4 CA CACA CA CA CACA CA 3/ 4 " 3/ 4 " 3/ 4 " 3/ 4 " C A C A C A C A C A C A C A C A 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 1 11 1 1 11 1 5 55 5 6 66 6 7 77 7 8 88 8 8 88 8 P PP P----8 88 8 P PP P----9 99 9 C A C A C A C A G G G G 1/ 2 " 1/ 2 " 1/ 2 " 1/ 2 " 9 99 9 10 1010 10 11 1111 11 12 1212 12 10 1010 10 10 1010 10 1 11 1----1 / 4 " 1/ 4 " 1/ 4 " 1/ 4 " 1 11 1----1 / 4 " 1/ 4 " 1/ 4 " 1/ 4 " 3/ 4 " 3/ 4 " 3/ 4 " 3/ 4 " 13 1313 13 13 1313 13 13 1313 13 13 1313 13 13 1313 13 13 1313 13 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PL404EnlargedPlumbingRemodelPlans22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetDRAWING NOTES 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 NOTE # DESCRIPTION 1 11 1 SEE PL102 FOR CONTINUATION.SEE PL102 FOR CONTINUATION.SEE PL102 FOR CONTINUATION.SEE PL102 FOR CONTINUATION.2 22 2 CONNECT 1" DCW, 1" DHW AND 1/2" DEIONIZED CONNECT 1" DCW, 1" DHW AND 1/2" DEIONIZED CONNECT 1" DCW, 1" DHW AND 1/2" DEIONIZED CONNECT 1" DCW, 1" DHW AND 1/2" DEIONIZED WATER AT APPROXIMATELY THIS LOCATION. FIELD WATER AT APPROXIMATELY THIS LOCATION. FIELD WATER AT APPROXIMATELY THIS LOCATION. FIELD WATER AT APPROXIMATELY THIS LOCATION. FIELD VERIFY EXACT LOCATION AND SIZE OF EXISTING.VERIFY EXACT LOCATION AND SIZE OF EXISTING.VERIFY EXACT LOCATION AND SIZE OF EXISTING.VERIFY EXACT LOCATION AND SIZE OF EXISTING.3 33 3 D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N I N W A L L T O DROP 1/2" DEIONIZED WATER DOWN IN WALL TO DROP 1/2" DEIONIZED WATER DOWN IN WALL TO DROP 1/2" DEIONIZED WATER DOWN IN WALL TO LEVEL BELOW. SEE PL402 FOR CONTINUATION.LEVEL BELOW. SEE PL402 FOR CONTINUATION.LEVEL BELOW. SEE PL402 FOR CONTINUATION.LEVEL BELOW. SEE PL402 FOR CONTINUATION.4 44 4 D R O P 1 / 2 " D E I O N I Z E D W A T E R D O W N I N W A L L A N D DROP 1/2" DEIONIZED WATER DOWN IN WALL AND DROP 1/2" DEIONIZED WATER DOWN IN WALL AND DROP 1/2" DEIONIZED WATER DOWN IN WALL AND CONNECT TO DEIONIZED WATER SPOUT.CONNECT TO DEIONIZED WATER SPOUT.CONNECT TO DEIONIZED WATER SPOUT.CONNECT TO DEIONIZED WATER SPOUT.5 55 5 C O N N E C T N E W 1 / 2 " G A S A N D 1 / 2 " A I R T O CONNECT NEW 1/2" GAS AND 1/2" AIR TO CONNECT NEW 1/2" GAS AND 1/2" AIR TO CONNECT NEW 1/2" GAS AND 1/2" AIR TO EXISTING BELOW COUNTER. ROUTE UNDER EXISTING BELOW COUNTER. ROUTE UNDER EXISTING BELOW COUNTER. ROUTE UNDER EXISTING BELOW COUNTER. ROUTE UNDER COUNTER AS SHOWN TO NEW GAS NOZZLES.COUNTER AS SHOWN TO NEW GAS NOZZLES.COUNTER AS SHOWN TO NEW GAS NOZZLES.COUNTER AS SHOWN TO NEW GAS NOZZLES.FIELD VERIFY.FIELD VERIFY.FIELD VERIFY.FIELD VERIFY.6 66 6 C O N N E C T N E W 3 / 4 " C O M P R E S S E D A I R T O CONNECT NEW 3/4" COMPRESSED AIR TO CONNECT NEW 3/4" COMPRESSED AIR TO CONNECT NEW 3/4" COMPRESSED AIR TO EXISTING IN CEILING SPACE AT APPROXIMATELY EXISTING IN CEILING SPACE AT APPROXIMATELY EXISTING IN CEILING SPACE AT APPROXIMATELY EXISTING IN CEILING SPACE AT APPROXIMATELY THIS LOCATION. FIELD VERIFY EXACT LOCATION.THIS LOCATION. FIELD VERIFY EXACT LOCATION.THIS LOCATION. FIELD VERIFY EXACT LOCATION.THIS LOCATION. FIELD VERIFY EXACT LOCATION.7 77 7 D R O P 1 / 2 " C O M P R E S S E D A I R D O W N O N W A L L T O DROP 1/2" COMPRESSED AIR DOWN ON WALL TO DROP 1/2" COMPRESSED AIR DOWN ON WALL TO DROP 1/2" COMPRESSED AIR DOWN ON WALL TO 48" A.F.F. TERMINATE WITH QUICK DISCONNECT 48" A.F.F. TERMINATE WITH QUICK DISCONNECT 48" A.F.F. TERMINATE WITH QUICK DISCONNECT 48" A.F.F. TERMINATE WITH QUICK DISCONNECT FOR FUTURE CONNECTION.FOR FUTURE CONNECTION.FOR FUTURE CONNECTION.FOR FUTURE CONNECTION.8 88 8 D R O P 1 / 2 " C O M P R E S S E D A I R , 1 / 2 " N A T U R A L G A S DROP 1/2" COMPRESSED AIR, 1/2" NATURAL GAS DROP 1/2" COMPRESSED AIR, 1/2" NATURAL GAS DROP 1/2" COMPRESSED AIR, 1/2" NATURAL GAS AND 1/2" DOMESTIC COLD WATER DOWN IN WALL AND 1/2" DOMESTIC COLD WATER DOWN IN WALL AND 1/2" DOMESTIC COLD WATER DOWN IN WALL AND 1/2" DOMESTIC COLD WATER DOWN IN WALL AND CONNECT INTO RELOCATED FUME HOODS.AND CONNECT INTO RELOCATED FUME HOODS.AND CONNECT INTO RELOCATED FUME HOODS.AND CONNECT INTO RELOCATED FUME HOODS.9 99 9 R I S E 1 / 2 " C O M P R E S S E D A I R T A K E O F F O F F O F T H E RISE 1/2" COMPRESSED AIR TAKEOFF OFF OF THE RISE 1/2" COMPRESSED AIR TAKEOFF OFF OF THE RISE 1/2" COMPRESSED AIR TAKEOFF OFF OF THE TOP OF THE COMPRESSED AIR LINE.TOP OF THE COMPRESSED AIR LINE.TOP OF THE COMPRESSED AIR LINE.TOP OF THE COMPRESSED AIR LINE.10 1010 10 R O U T E 1 / 4 " C O N T I N U O U S F L E X I B L E C O P P E R ROUTE 1/4" CONTINUOUS FLEXIBLE COPPER ROUTE 1/4" CONTINUOUS FLEXIBLE COPPER ROUTE 1/4" CONTINUOUS FLEXIBLE COPPER TUBING IN CEILING SPACE AS SHOWN WITHOUT TUBING IN CEILING SPACE AS SHOWN WITHOUT TUBING IN CEILING SPACE AS SHOWN WITHOUT TUBING IN CEILING SPACE AS SHOWN WITHOUT SEAMS OR JOINTS.SEAMS OR JOINTS.SEAMS OR JOINTS.SEAMS OR JOINTS.11 1111 11 D R O P 1 / 4 " C O P P E R T U B I N G D O W N O N W A L L . DROP 1/4" COPPER TUBING DOWN ON WALL.DROP 1/4" COPPER TUBING DOWN ON WALL.DROP 1/4" COPPER TUBING DOWN ON WALL.OWNER TO CONNECT 1/4" COPPER TUBING TO OWNER TO CONNECT 1/4" COPPER TUBING TO OWNER TO CONNECT 1/4" COPPER TUBING TO OWNER TO CONNECT 1/4" COPPER TUBING TO HYDROGEN, ETHYLENE AND ARGON OWNER HYDROGEN, ETHYLENE AND ARGON OWNER HYDROGEN, ETHYLENE AND ARGON OWNER HYDROGEN, ETHYLENE AND ARGON OWNER PROVIDED FLOW CONTROL STATION AND PROVIDED FLOW CONTROL STATION AND PROVIDED FLOW CONTROL STATION AND PROVIDED FLOW CONTROL STATION AND ASSOCIATED TANKS.ASSOCIATED TANKS.ASSOCIATED TANKS.ASSOCIATED TANKS.12 1212 12 D R O P 1 / 4 " C O P P E R T U B I N G A N D 1 / 2 " DROP 1/4" COPPER TUBING AND 1/2"DROP 1/4" COPPER TUBING AND 1/2"DROP 1/4" COPPER TUBING AND 1/2"COMPRESSED AIR DOWN ON WALL. OWNER TO COMPRESSED AIR DOWN ON WALL. OWNER TO COMPRESSED AIR DOWN ON WALL. OWNER TO COMPRESSED AIR DOWN ON WALL. OWNER TO CONNECT HYDROGEN, ETHYLENE, ARGON AND CONNECT HYDROGEN, ETHYLENE, ARGON AND CONNECT HYDROGEN, ETHYLENE, ARGON AND CONNECT HYDROGEN, ETHYLENE, ARGON AND COMPRESSED AIR TO TUBE FURNACE.COMPRESSED AIR TO TUBE FURNACE.COMPRESSED AIR TO TUBE FURNACE.COMPRESSED AIR TO TUBE FURNACE.13 1313 13 D E I O N I Z E D W A T E R P I P I N G A N D A S S O C I A T E D DEIONIZED WATER PIPING AND ASSOCIATED DEIONIZED WATER PIPING AND ASSOCIATED DEIONIZED WATER PIPING AND ASSOCIATED FAUCET AND VALVING ARE PART OF ADD.FAUCET AND VALVING ARE PART OF ADD.FAUCET AND VALVING ARE PART OF ADD.FAUCET AND VALVING ARE PART OF ADD.ALTERNATE #5.ALTERNATE #5.ALTERNATE #5.ALTERNATE #5. SC A L E : SC A L E : SC A L E : SC A L E : PL 4 0 4 PL 4 0 4 PL 4 0 4 PL 4 0 4 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' 1/ 4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 2 P L U M B I N G R E M O D E L P L A N - WA S T E & V E N T 1 11 1 SC A L E : SC A L E : SC A L E : SC A L E : PL 4 0 4 PL 4 0 4 PL 4 0 4 PL 4 0 4 1/4 " = 1 ' 1/4 " = 1 ' 1/4 " = 1 ' 1/4 " = 1 ' ----0"0"0"0" EN L A R G E D L E V E L 0 2 P L U M B I N G R E M O D E L P L A N - WA T E R & G A S 2 22 2 0 00 0 2. 5 2. 5 2 . 5 2. 5 5 55 5 5 55 5 10 1010 10 INSERTS OR BEAM /TRUSS CONNECTION CINCH ANCHORSWELDED STEEL WALL BRACKET ANGLE RODADJUSTABLE PIPE STANDTHRU-BOLTEYE BOLTS TURNBUCKLE U-BOLTWALL BRACKET U-BOLTSSTEEL OFFSET C I N C H A N C H O R S EYE BOLT PIPE CLAMPRODTURNBUCKLE I-BEAM STEEL PLATEBLOCK WALLCLAMPSANGLEU-BOLTSROD SPLIT RING CLEVIS HANGER IN S E R T S O R B E A M / TR U S S C O N N E C T I O N C-CLAMPLOCK NUT TYP.STEEL CLEAVIS TE S T T E E C L FINISHED WALL SURFACE PL U G CL E A N O U T TH R E A D E D COVER PLATE WITH SECURING SCREWCENTERLINEMOUNTING HEIGHT CHART DESCRIPTION URINAL SINKLAVATORY GENERAL WALLLOCATION NOTE:12"12"48"HEIGHT 12"COORDINATE WITH ARCHITECT PRIOR TO INSTALLING AT A HEIGHT OTHER THAN THAT LISTED ABOVE.CLEANOUT TO GRADE (COTG) FL O O R C L E A N O U T ( F C O ) 1/8 " B E N D I F C L E A N O U T OC C U R S A T E N D O F L I N E LENGTH TO SUITCAST IRON WASTE LINE,1/8" CAST IRON BEND WASTE LINECAST IRON WASTE LINE,LENGTH TO SUIT1/8" CAST IRON BEND OCCURS AT END OF LINE1/8" BEND IF CLEANOUTWASTE LINE CO V E R . T O P O F C O V E R CL E A N O U T A N D A C C E S S TO B E F L U S H W / T O P OF F L O O R FLOOR LINE FINISH GRADEBRASS CLEANOUT PLUG W/ COUNTER SUNK HEAD.TROWEL SMOOTH AND EDGE.16" SQUARE CONCRETE PAD BO D Y SL O P E NO T E : GR O U T 1- 1 / 4 " M I N . SIM I L A R F O R FL O O R S I N K S . FL O O R D R A I N SC H E D U L E F O R S I Z E DR A I N ) , S E E P L U M B I N G (T H R E A D S I N T O F L O O R DR A I N A G E P I P I N G FL O O R S L A B EX I S T I N G 30 " x 3 0 " 4 0 M I L . P V C SH O W E R P A N L I N E R . TU R N D O W N U N D E R DR A I N C L A M P ST R A I N E R FL O O R D R A I N CO L L A R CL A M P I N G TH A N F I X T U R E T O P OF H O L E 6 " L A R G E R FI N I S H E D F L O O R . T O P SL O P E 30 " x 3 0 " SL O P E SL O P E RWAET R T P A SE W E R GA S E S TR A P P R I M E R VA C U U M B R E A T H E R PO R T S . 1/2 " VA L V E ( T P - 1 ) CO L D W A T E R M A I N . 1/2 " FI N . F L O O R FL O O R D R A I N 2X 6 B L O C K I N G I N WA L L F O R W A T E R LI N E S U P P O R T . PL U M B I N G F I X T U R E ES C U T C H E O N R I N G PI P I N G T O 15 1 0 1 WA L L S T U D S 15 1 0 5 WA T E R P I P I N G GR A V E L HO T O R C O L D AL L A R O U N D ) SA N D ( 3 " M I N . CO N C R E T E F L O O R "T H E R M A - C E L " CO M P A C T E D PI P E I N S U L A T I O N DIR T F I L L 3'- 0 " 5'- 0 " 6'- 0 " SE R V I C E S I N K SE R V I C E S I N K F A U C E T 3/4 " D H W A N D D C W FL O O R 1/2 " R E D U C E D P R E S S U R E PR I N C I P L E B A C K F L O W PR E V E N T E R . 1/2 " PR V S E T @ 3 5 PS I A N D 5 G P M . PR E S S U R E G U A G E . 1/2 " S U P P L Y B R A N C H , TY P I C A L E A C H F L O O R . HB - 2 , C O N S I S T I N G O F A 1 / 2 " BA L L V A L V E , A N D 3 / 4 " H O S E CO N N E C T I O N F O R S U P P L Y TO " C U S T O D I A L S O L U T I O N ST A T I O N ( N . I . C . ) " . 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : ????PL501PlumbingDetails22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel Bid SetSCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE PL 5 0 1 PL 5 0 1 PL 5 0 1 PL 5 0 1 TYPICAL PIPE SUPPORTS DETAIL 1 11 1 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE PL501 PL501 PL501 PL501WALL CLEANOUT DETAIL 2 22 2 SCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE PL501 PL501 PL501 PL501CLEANOUT DETAILS 3 33 3 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E PL 5 0 1 PL 5 0 1 PL 5 0 1 PL 5 0 1 FL O O R D R A I N I N E X I S T I N G F L O O R D E T A I L 4 44 4 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E PL 5 0 1 PL 5 0 1 PL 5 0 1 PL 5 0 1 TR A P P R I M E R D E T A I L 5 55 5 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E PL 5 0 1 PL 5 0 1 PL 5 0 1 PL 5 0 1 PI P E S U P P O R T D E T A I L 6 66 6 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E PL 5 0 1 PL 5 0 1 PL 5 0 1 PL 5 0 1 UN D E R G R O U N D P I P E D E T A I L 7 77 7 SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E SC A L E : N O N E PL 5 0 1 PL 5 0 1 PL 5 0 1 PL 5 0 1 SE R V I C E S I N K D E T A I L 8 88 8 C I R C U I T I N G & G E N E R A L S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N K E Y E D N O T E R E F E R E N C E 1 B R A N C H C I R C U I T H O M E -R U N T O P A N E L I N D I C A T E D A -1 ,3 ,5 3 /4 "C .-6 #1 2 ,1 #1 2 G Q T Y & S I Z E O F E Q U I P M E N T G R O U N D C O N D U C T O R Q TY & S I ZE O F N E U TR A L A N D P H A S E C O N D U C T O R (S ) S I Z E O F C O N D U I T A -1 ,3 ,5 3 /4 "C .-6 #1 2 ,1 #1 2 G P A N E L A N D C I R C U I T D E S I G N A T I O N S E Q U I P M E N T G R O U N D I N G C O N D U C T O R T I C K M A R K S N E U T R A L C O N D U C T O R (S ) P H A S E A N D /O R S W I T C H -L E G C O N D U C T O R (S ) B R A N C H C I R C U I T /F E E D E R C O N C E A L E D I N C E I L I N G O R W A L L B R A N C H C I R C U I T /F E E D E R C O N C E A L E D U N D E R G R O U N D O R F L O O R N E W E Q U I P M E N T , D E V I C E S , E T C . E X I S T I N G E Q U I P M E N T , D E V I C E S , E T C . D E M O L I T I O N E Q U I P M E N T , D E V I C E S , E T C . D E T A I L # / S H E E T R E F E R E N C E 1 / E S 1 0 1 *2 5 ,0 0 0 A C A L C U L A T E D A V A I L A B L E F A U L T C U R R E N T A T E Q U I P M E N T (S E E P O W E R R I S E R ) F I R E A L A R M S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N D E T E C T O R S U B S C R I P T S P P H O T O E L E C T R I C S M O K E D E T E C T O R D D U C T S M O K E D E T E C T O R I D I N -D U C T S M O K E D E T E C T O R H H E A T D E T E C T O R M M U L T I -S T A T I O N S M O K E D E T E C T O R (1 2 0 V W /B A T T E R Y B A C K U P ) M /S M U L T I -S T A T I O N S M O K E D E T E C T O R W /V I S I B L E S T R O B E (1 2 0 V W /B A T T E R Y B A C K U P ) M /C M U L T I -S T A T I O N S M O K E / C A R B O N M O N O X I D E D E T E C T O R (1 2 0 V W /B A T T E R Y B A C K U P ) F I R E A L A R M C O N T R O L P A N E L (W A L L M O U N T E D , T O P A T 6 '-0 ' A F F ) FFACP N O T I F I C A T I O N D E V I C E E X T E N D E R P A N E L . P R O V I D E Q T Y A S R E Q U I R E D B A S E D O N D E V I C E V O L T A G E D R O P C A L C 'S P E R N F P A 7 2 R E Q U I R E M E N T S . (W A L L M O U N T E D , T O P A T 5 '-0 ' A F F ) R E M O T E A N N U C I A T O R P A N E L (F L U S H M O U N T E D I N W A L L A T 5 '-0 ' A F F ) N A C R A M A N U A L P U L L S T A T I O N (M O U N T I N G H E I G H T P E R A D A & N F P A 7 2 ) M A G N E T I C D O O R H O L D O P E N A D D R E S S A B L E C O N T R O L /R E L A Y M O D U L E M MCM A D D R E S S A B L E M O N I T O R I N G M O D U L E F I R E A L A R M F L O W S W I T C H F I R E A L A R M T A M P E R S W I T C H F S T S W A L L O R C E I L I N G M O U N T E D F I R E A L A R M H O R N O N L Y W A L L M O U N T E D F I R E A L A R M S T R O B E O R H O R N /S T R O B E P R O V I D E C A N D E L A R A T I N G A S R E Q U I R E D B Y N F P A 7 2 # A D D R E S S A B L E D E T E C T O R W I T H B A S E E X T E R I O R 1 2 0 V F I R E B E L L , I N S T A L L N E X T T O F D C . F I R E /S M O K E D A M P E R ; C O O R D I N A T E L O C A T I O N S W I T H M E C H . D R A W I N G S S D A . D O N O T I N S T A L L M O R E T H A N (1 0 ) N O T I F I C A T I O N A P P L I A N C E S O N A N Y S I N G L E C L A S S "A " S I G N A L C I R C U I T . D O N O T E X C E E D 4 0 0 F T . O F N O . 1 4 W I R E I N T H E T O T A L L O O P . B . N F P A A L L O W S N O T I F I C A T I O N A P P L I A N C E S T O B E M O U N T E D A T A H E I G H T R A N G E B E T W E E N 8 0 " T O 9 6 " A B O V E F I N I S H F L O O R . T H E P R E F E R R E D H E I G H T I S 8 0 ". I F T H I S C O N F L I C T S W I T H O T H E R T R A D E S O R R O O M F U R N I S H I N G S , L O C A T E A S C L O S E T O 8 0 " A S P O S S I B L E , N O T E X C E E D I N G 9 6 ". A L L N O T I F I C A T I O N A P P L I A N C E S I N A C O M M O N R O O M O R L I N E O F S I G H T S H A L L B E L O C A T E D A T A C O M M O N H E I G H T . C . M O U N T P U L L S T A T I O N S A T 4 6 -4 8 " A .F .F . T O T H E O P E R A T I N G H A N D L E T O M E E T A D A R E Q U I R E M E N T S . D . D O N O T C O N N E C T T H E F I R E A L A R M S Y S T E M T O A N Y D E V I C E W H I C H H A S A P O W E R H E L D C O N T A C T S .(F L O W , T A M P E R , H O O D S Y S T E M , D U C T D E T E C T O R , E T C ..F A L S E A L A R M W I L L O C C U R . E . E L E C T R I C A L C O N T R A C T O R S H A L L S U P P L Y A N D I N S T A L L C O N D U C T O R Q U A N T I T I E S P E R F I R E A L A R M S Y S T E M S U P P L I E R , A N D A S P E R N F P A A N D N E C R E Q U I R E M E N T S . F . D O N O T I N S T A L L A N Y S M O K E O R H E A T D E T E C T O R S W I T H I N 3 F E E T O F A N Y A I R D I F F U S E R . G . D O N O T E X C E E D 2 5 0 0 F E E T O N A N Y A D D R E S S A B L E D E V I C E R U N . D O N O T E X C E E D 1 2 0 D E V I C E S O N A N Y O N E A D D R E S S A B L E D E V I C E R U N . H . A L L A I R H A N D L I N G E Q U I P M E N T 2 0 0 0 C F M O R M O R E M U S T B E S H U T D O W N U P O N F I R E A L A R M A S P E R L I F E S A F E T Y C O D E S . I . A L L C L A S S "B " I N I T I A T I N G C I R C U I T S W I T H A D D R E S S A B L E D E V I C E S N E E D E O L R . (E N D O F L I N E R E S I S T O R S ). J . I N C O R R I D O R S , N O T I F I C A T I O N A P P L I A N C E S M U S T B E L O C A T E D W I T H I N 1 5 ' F R O M E N D S O F C O R R I D O R S A N D A M A X I M U M O F 1 0 0 ' S P A C I N G . K . N O T I F I C A T I O N A P P L I A N C E S T O B E S Y N C H R O N I Z E D T O P R O V I D E A 3 -3 -3 T E M P O R A L P A T T E R N . L . A L L W I R I N G A N D C O N D U I T R O U T I N G T O B E A S D E S C R I B E D O N S U P P L I E D S H O P D R A W I N G S . F I R E A L A R M P L A N I S S H O W N F O R G E N E R A L L O C A T I O N A N D L A Y O U T O N L Y . M . T H E F I R E A L A R M S Y S T E M T O B E I N C O M P L I A N C E W I T H A L L A P P L I C A B L E L O C A L , S T A T E A N D A D A R E Q U I R E M E N T S . N . E L E C T . C O N T R . T O C O N N E C T S P R I N K L E R S Y S T E M T A M P E R S W I T C H E S A N D F L O W V A L V E S T O F I R E A L A R M S Y S T E M A S R E Q U I R E D . S E E F I R E S P R I N K L E R S Y S T E M D R A W I N G S F O R E X A C T L O C A T I O N S A N D Q U A N T I T I E S . G E N E R A L F I R E A L A R M S Y S T E M N O T E S F I R E A L A R M S M O K E D A M P E R S D C E I L I N G M O U N T E D F I R E A L A R M S T R O B E O R H O R N /S T R O B E P R O V I D E C A N D E L A R A T I N G A S R E Q U I R E D B Y N F P A 7 2 L I G H T I N G S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N P A R K I N G A R E A P O L E L I G H T , S I N G L E O R D O U B L E H E A D A S I N D I C A T E D O N D R A W I N G S . R E F E R T O L I G H T P O L E D E T A I L F O R P O L E I N F O R M A T I O N . 2 X 4 F L U O R E S C E N T O R L E D F I X T U R E 2 X 2 F L U O R E S C E N T O R L E D F I X T U R E S U R F A C E M O U N T E D F L U O R E S C E N T O R L E D F I X T U R E S T R I P F L U O R E S C E N T O R L E D F I X T U R E W A L L M O U N T E D F L U O R E S C E N T O R L E D F I X T U R E E X T E R I O R W A L L M O U N T E D F I X T U R E R O U N D R E C E S S E D F I X T U R E S U R F A C E O R P E N D A N T F I X T U R E L I G H T F I X T U R E S U B S C R I P T S N L N I G H T -L I G H T (C O N N E C T T O U N S W I T C H E D L E G O F C I R C U I T ) E X I T S I G N , W A L L O R C E I L I N G M O U N T I N G A S R E Q U I R E D (S I N G L E O R D O U B L E F A C E ) D I R E C T I O N A L C H E V R O N S A S I N D I C A T E D ; C O N N E C T T O U N S W I T C H E D L E G O F L I G H T I N G C I R C U I T T H A T I S I N T H E S A M E A R E A A S T H E E X I T S I G N S . S H A D E D F I X T U R E I N D I C A T E S A N E M E R G E N C Y F I X T U R E . P R O V I D E W I T H E M E R G . B A T T E R Y P A C K O R C O N N E C T T O E M E R G E N C Y P O W E R S Y S T E M (W H E R E A P P L I C A B L E ). C O N N E C T B A T T E R Y P A C K T O U N S W I T C H E D L E G O F L I G H T I N G C I R C U I T T H A T S E R V E S T H E S A M E A R E A A S T H E E M E R G E N C Y F I X T U R E . P R O V I D E W I T H T E S T L I G H T A N D S W I T C H . C E I L I N G M O U N T E D O C C U P A N C Y S E N S O R , R E F E R T O O C C U P A N C Y S E N S O R /S W I T C H S C H E D U L E F O R S E N S O R T Y P E A N D A D D I T I O N A L I N F O R M A T I O N . S W I T C H M O U N T E D O C C U P A N C Y S E N S O R , L O W V O L T A G E S W I T C H P O D O R D I M M E R S W I T C H , R E F E R T O O C C U P A N C Y S E N S O R /S W I T C H S C H E D U L E F O R T Y P E A N D A D D I T I O N A L I N F O R M A T I O N . S I N G L E -P O L E S W I T C H (S E E S U B -S C R I P T S B E L O W F O R A D D I T I O N A L I N F O R M A T I O N ) S W I T C H S U B S C R I P T S 3 3 -W A Y S W I T C H 4 4 -W A Y S W I T C H D D I M M E R S W I T C H (C O M P A T I B L E W / L O A D & L T G T Y P E S ) F 7 -D A Y P R O G R A M M A B L E T I M E R S W I T C H (I N T E R M A T I C M O D E L E I 5 0 0 W C S E R I E S ) P P I L O T L I G H T E D S W I T C H F 1 L I G H T F I X T U R E T Y P E D E S I G N A T I O N S ### W A L L O R C E I L I N G M O U N T E D E M E R G E N C Y L I G H T I N G U N I T W /B A T T E R Y P A C K C O N N E C T T O U N S W I T C H E D L E G O F L I G H T I N G C I R C U I T T H A T I S I N T H E S A M E A R E A A S T H E E M E R G E N C Y L I G H T . L V L O W -V O L T A G E S W I T C H (P E R D W G 'S ) T T H E R M A L -O V E R L O A D S W I T C H M S W I T C H S U P P L I E D W I T H E Q U I P M E N T , I N S T A L L E D B Y E .C . W P W E A T H E R P R O O F 2 P D O U B L E P O L E , S I N G L E T H R O W S W I T C H G E N E R A L L I G H T I N G N O T E S : A . S Y M B O L S S H O W N A B O V E M A Y N O T R E P R E S E N T A L L L I G H T F I X T U R E S U S E D O N P R O J E C T , R E F E R T O L I G H T F I X T U R E S C H E D U L E F O R A C T U A L F I X T U R E I N F O R M A T I O N I N C L U D I N G F I X T U R E T Y P E , L A M P I N G , M O U N T I N G A N D E T C . B . J U N C T I O N B O X E S F O R L I G H T I N G C I R C U I T I N G A R E N O T S H O W N F O R C L A R I T Y . T H E E .C . I S R E S P O N S I B L E F O R P R O V I D I N G A N D I N S T A L L I N G A L L J U N C T I O N B O X E S R E Q U I R E D F O R C I R C U I T I N G O F A L L L I G H T F I X T U R E S T H A T A R E N O T L I S T E D F O R "T H R O U G H -B R A N C H C I R C U I T W I R I N G ". C . I N G E N E R A L A L L S W I T C H -L E G C O N D U C T O R S M A Y N O T B E S H O W N O N D R A W I N G S ; E .C . S H A L L P R O V I D E A N D I N S T A L L C O N D U C T O R S A S R E Q U I R E D T O A C H I E V E C O N T R O L S C H E M E S I N D I C A T E D A N D D E S C R I B E D O N D R A W I N G S . I N C L U D I N G A L L 0 - 1 0 V D I M M I N G C O N T R O L S B E T W E E N S W I T C H A N D F I X T U R E S . D . A L L B A T T E R Y E X I T S I G N S A N D E M E R G E N C Y L I G H T I N G T O B E C O N N E C T E D T O T H E U N S W I T C H E D L E G O F T H E L I G H T I N G C I R C U I T I N T H E A R E A . ### FM P O W E R S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N E L E C T R I C A L S W I T C H B O A R D E Q U I P M E N T , (S E E P O W E R R I S E R A N D P A N E L S C H E D U L E S F O R A D D I T I O N A L I N F O R M A T I O N ) 'M S B ' 'T ##' D R Y -T Y P E T R A N S F O R M E R , (S E E P O W E R R I S E R F O R A D D I T I O N A L I N F O R M A T I O N ) 'L A ' E L E C T R I C A L P A N E L B O A R D , (S E E P O W E R R I S E R A N D P A N E L S C H E D U L E S F O R A D D I T I O N A L I N F O R M A T I O N ) D I S C O N N E C T S W I T C H , S I Z E /P O L E S /T Y P E A S I N D I C A T E D T Y P E S : 1 =N E M A 1 , 3 R =N E M A 3 R , 4 X =N E M A 4 X F U S E D D I S C O N N E C T S W I T C H , S I Z E /P O L E S /T Y P E A S I N D I C A T E D T Y P E S : 1 =N E M A 1 , 3 R =N E M A 3 R , 4 X =N E M A 4 X C O M B I N A T I O N S T A R T E R & F U S E D D I S C O N N E C T S W I T C H , S I Z E /P O L E S /T Y P E A S I N D I C A T E D . T Y P E S : 1 =N E M A 1 , 3 R =N E M A 3 R , 4 X =N E M A 4 X J J U N C T I O N B O X C R = C O R D R E E L ; S E E D R A W I N G S F O R I N F O R M A T I O N C D = C O R D D R O P ; S E E D R A W I N G S F O R I N F O R M A T I O N E Q U I P M E N T C O N N E C T I O N ; C O O R D I N A T E C O N N E C T I O N W I T H E Q U I P M E N T P R I O R T O R O U G H -I N M O T O R C O N N E C T I O N P O W E R A N D /O R D A T A S E R V I C E P O L E F L O O R B O X (S E E F L O O R B O X S C H E D U L E F O R A D D I T I O N A L I N F O R M A T I O N ) P U S H B U T T O N S T A T I O N F B # S P E C I A L R E C E P TA C L E (C O O R D I N A TE N E M A TY P E W I TH E Q U I P .) (R E FE R TO P A N E L S C H E D U L E S FO R A M P S ) C E I L I N G M O U N T E D D U P L E X R E C E P TA C L E (C O O R D I N A TE P L A C E M E N T W I TH C E I L I N G E Q U I P M E N T P R I O R TO R O U G H -I N ) D U P L E X R E C E P T A C L E , U L T A M P E R -R E S I S T A N T W H E R E R E Q U I R E D B Y N E C G F C I -T Y P E D U P L E X R E C E P T A C L E , U L T A M P E R -R E S I S T A N T W H E R E R E Q U I R E D B Y N E C D O U B L E -D U P L E X R E C E P T A C L E , U L T A M P E R -R E S I S T A N T W H E R E R E Q U I R E D B Y N E C G F C I -T Y P E D O U B L E -D U P L E X R E C E P T A C L E , U L T A M P E R -R E S I S T A N T W H E R E R E Q U I R E D B Y N E C R E C E P TA C L E A N D E Q U I P M E N T S U B S C R I P T S A C A B O V E C O U N T E R W P W E A T H E R P R O O F (U L L I S T E D W E A T H E R -R E S I S T A N T ) 4 2 " M O U N T I N G H E I G H T A F F O R A F G R E F R E F R I G E R A T O R M M I C R O W A V E M /R M I C R O W A V E /R A N G E H O O D (L O C A T E A B O V E R A N G E ) U S B D U P L E X R E C P T . W I T H (2 ) U S B C H A R G I N G P O R T S D W D I S H W A S H E R , I N S T A L L P E R N E C 4 2 2 .1 6 (B )(2 ) D /D W D I S P O S A L /D I S H W A S H E R , I N S T A L L P E R N E C 4 2 2 .1 6 (B )(2 ) T V R E C E P T . D E D I C A T E D T O T V ; F I E L D V E R I F Y H E I G H T W / T V P R I O R T O R O U G H -I N . E W C E L E C T R I C W A T E R C O O L E R ; P R O V I D E G F C I P R O T E C T I O N P E R N E C 4 2 2 .5 (A ) H V A C T H E R M O S T A T O R S E N S O R ; P R O V I D E & I N S T A L L B A C K B O X ,3 /4 " C O N D U I T A N D C O N D U C T O R S T O A S S O C I A T E D H V A C U N I T . C O O R D I N A T E E X A C T L O C A T I O N & S I Z E A N D N U M B E R O F C O N D U C T O R S W I T H M .C . T S O R E X H A U S T F A N C O N N E C TI O N D C L O T H E S D R Y E R (N E M A 1 4 -3 0 R ) R E L E C T R I C R A N G E (N E M A 1 4 -5 0 R ) W W E L D E R R E C E P T A C L E 2 0 8 /2 4 0 V - N E M A 6 -5 0 R G E N E R A L S P E C I A L S Y S TE M N O T E S : A . A L L D E V I C E S S H O W N A T O R N E A R M I L L W O R K /C A S E W O R K S H A L L B E C O O R D I N A T E D W I T H T H E A R C H I T E C T U R A L E L E V A T I O N D R A W I N G S A N D M I L L W O R K I N S T A L L E R T O I N S U R E P R O P E R M O U N T I N G H E I G H T S . C O N T R A C T O R S H A L L A D J U S T D E V I C E S A S N E C E S S A R Y I N O R D E R T O P O S I T I O N D E V I C E S S U C H T H A T T H E Y W I L L N O T F A L L B E H I N D M I L L W O R K , C A B I N E T S O R B E D I R E C T L Y A B O V E S I N K S O R M I D W A Y B E T W E E N T I L E W O R K /W A L L O R W A I N S C O A T I N G , E T C . B . I T S H A L L B E T H E R E S P O N S I B I L I T Y O F T H E C O N T R A C T O R T O I N S T A L L A G F C I T Y P E R E C E P T A C L E F O R A L L R E C P T A C L E S S H O W N I N T O I L E T R M S , B A T H R O O M S , K I T C H E N S /S E R V I N G A R E A S , R O O F T O P , O U T D O O R S O R W I T H I N 6 F T O F A N Y S I N K , B A S I N , T U B O R F L O O R S I N K A N D A L L O T H E R A R E A S D E F I N E D B Y T H E N E C . S P L I T -W I R E D R E C E P T A C L E , H A L F O F R E C E P T . S H A L L B E S W I T C H E D O T H E R H A L F S H A L L H A V E C O N S T A N T P O W E R . S P E C I A L S Y S T E M S S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N D A T A O U T L E T ; _= # O F D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) _D -X T E L E P H O N E O U T L E T ; _= # O F T E L E P H O N E C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) _T -X T E L E P H O N E /D A T A O U T L E T ; _= # O F T E L E P H O N E /D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) _T /_D -X C E I L I N G M O U N T E D D A T A O U T L E T ; _= # O F D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) _D -X A . C O M M U N I C A T I O N S C A B L E S S H A L L H A V E B E N D S N O G R E A T E R T H A N 9 0 D E G . B . C O N D U I T S F O R C O M M U N I C A T I O N S C A B L I N G S H A L L H A V E A M A X I M U M B E N D R A D I U S N O T M O R E T H A N 1 0 X T H E D I A M E T E R O F T H E C O N D U I T . C . A L L C O M M U N I C A T I O N S C O N D U I T S S H A L L B E T E R M I N A T E D W I T H A N I N S U L A T E D N O N -M E T A L L I C B U S H I N G A T B O T H E N D S . D . C O M M U N I C A T I O N S C O N D U I T S S H A L L H A V E N O M O R E T H A N (2 ) 9 0 'S W I T H O U T A P U L L B O X . P U L L B O X E S S H A L L B E L O C A T E D I N A C C E S S I B L E L O C A T I O N S A N D S H A L L B E S I Z E D A T L E A S E D 1 2 X T H E L A R G E S T C O N D U I T D I A M E T E R I N L E N G T H A N D M I N , 4 " D E E P A N D 8 " W I D E . E . I T S H A L L B E T H E R E S P O N S I B I L I T Y O F T H E E .C . T O I N S U R E T H A T T H E P A T H W A Y F O R T H E D A T A C A B L I N G D O E S N O T C R E A T E C A B L E L E N G T H S T O E X C E E D S T H E L E N G T H O F 2 9 5 F T F R O M O U T L E T T O P A T C H P A N E L , T H I S I N C L U D E S S E R V I C E L O O P S A N D P A T C H C O R D S . F . W H E R E C A B L E T R A Y I S U T I L I Z E D I N T H E P R O J E C T . C O M M U N I C A T I O N C O N D U I T S E N D I N G A T T H E C A B L E T R A Y S H A L L E X T E N D 1 " O V E R T H E S I D E I N T O T H E T R A Y . G E N E R A L S P E C I A L S Y S T E M N O T E S : ### _D -X S P E C I A L S Y S T E M S N O T E S : 1 . U T I L I Z E 4 1 1 /1 6 " D E E P B O X W I T H R E Q U I R E D M U D R I N G A N D C O N D U I T T O A B O V E N E A R E S T A C C E S S I B L E C E I L I N G O R D A T A R A C K , T E R M I N A T E W I T H I N S U L A T E D T H R O A T B U S H I N G . P R O V I D E Q T Y O F C A B L E S I N D I C A T E D F R O M O U T L E T T O N E A R E S T T E L E /D A T A R O O M . S E E D W G S F O R A D D I T I O N A L I N F O R M A T I O N . U T I L I Z E J -H O O K S 3 F T O N C E N T E R F O R S U P P O R T O F C A B L I N G W H E R E C A B L E T R A Y I S N O T I N S T A L L E D /S P E C I F I E D . 2 . C O N D U I T S I Z E ('X ' F R O M A B O V E ); 2 =1 /2 ", 3 =3 /4 ", 4 =1 ", 5 =1 -1 /4 ", 6 =1 -1 /2 " 3 . B L A N K (N O L A B E L ) = 4 -1 1 /1 6 " D E E P B O X W I T H R E Q U I R E D M U D R I N G A N D 1 " C O N D U I T T O A B O V E N E A R E S T A C C E S S I B L E C E I L I N G /C A B L E T R A Y , T E R M I N A T E W I T H I N S U L A T E D T H R O A T B U S H I N G , P R O V I D E P U L L S T R I N G . (U N L E S S O T H E R W I S E N O T E D ) W A L L /F L O O R E L E C T R I C A L P A T H W A Y S L E E V E ; I N S T A L L T H R O U G H W A L L O R F L O O R A S I N D I C A T E D . S L E E V E S S H A L L B E A B O V E A C C E S S I B L E C E I L I N G S I N A C C E S S I B L E L O C A T I O N , F I E L D V E R I F Y E X A C T L O C A T I O N T O A V O I D C O N F L I C T W I T H O T H E R T R A D E S A N D U T I L I T I E S . I F W A L L /F L O O R I S N O T F I R E R A T E D E .C . M A Y U T I L I Z E D E M T C O N D U I T S L E E V E S O F E Q U A L S I Z E . R E F E R T O A R C H I T E C T U R A L D R A W I N G S F O R F I R E R A T I N G S . (q t y ) = Q U A N T I T Y O F S L E E V E S A T L O C A T I O N E P 2 = 2 " H I L T I S P E E D S L E E V E C P -6 5 3 -B A E P 4 = 4 " H I L T I S P E E D S L E E V E C P -6 5 3 -B A ### F B # _D -X E L E C T R I C A L F L O O R B O X R E F E R T O "E L E C T R I C A L F L O O R B O X S C H E D U L E " F O R I N F O R M A T I O N . _= # O F D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E S 1 ,2 ,3 B E L O W ) T V A N D /O R A V B O X ; W I T H P O W E R , D A T A A N D /O R A V C O N N E C T I V I T Y ### = B O X I D : R E F E R T O "E L E C T R I C A L A V /T V B O X S C H E D U L E " F O R I N F O R M A T I O N . _= # O F D A T A C A B L E S , X =C O N D U I T S I Z E (S E E N O T E #2 B E L O W ) I N S T A L L C O N D U I T (S I Z E A S I N D I C A T E D ) F R O M B O X T O N E A R E S T A C C E S S I B L E C E I L I N G S P A C E W / D A T A C A B L I N G /T E R M I N A T I O N S A S I N D I C A T E D O N D R A W I N G S . W A L L ### F L O O R (q t y ) (q t y ) P 1 P H 2 /C 3 /C 3 P 3 P H 3 W 4 W A C A D A A F F A F G A I C A L A o r A M P A N N A P A T S A V A W G B F G C C A T V C B C C T V C K T C C P C T C U D S E A E .C .E M E M T E N T E P O E Q U I P E X F A F A C P F L A F M C G N D G .C .G E N G F I G F P H D H I D H O A H P H P S H V H Z I G I M C J -B O XABBREVIATIONSSINGLE P O L E S I N G L E -P H A S E TW O -C O N D U C TO R TH R E E -C O N D U C TO R TH R E E P O L E TH R E E -P H A S E TH R E E -W I R E FO U R -W I R E A B O V E C O U N TE R A M E R I C A N S W I TH D I S A B I L I T I E S A C T A B O V E F I N I S H E D F L O O R A B O V E F I N I S H E D G R A D E A M P E R E I N TE R R U P T I N G C A P A C I TY A L U M I N U M A M P E R E A N N U N C I A TO R A C C E S S P O I N T (W I R E L E S S D A TA )A U TO M A T I C T R A N S FE R S W I TC H A U D I O V I S U A L A M E R I C A N W I R E G A G E B E L O W F I N I S H E D G R A D E C E I L I N G M O U N T E D C A B L E TE L E V I S I O N C I R C U I T B R E A K E R C L O S E D C I R C U I T TE L E V I S I O N C I R C U I T C O N D U I T C O N T R O L P A N E L C U R R E N T TR A N S FO R M E R C O P P E R D I S C O N N E C T S W I TC H E A C H E L E C TR I C A L C O N T R A C TO R E M E R G E N C Y E L E C TR I C A L M E TA L L I C T U B I N G E L E C TR I C A L N O N M E T A L L I C TU B I N G E M E R G E N C Y P O W E R O F F E Q U I P M E N T E X I S TI N G FI R E A L A R M FI R E A L A R M C O N TR O L P A N E L FU L L L O A D A M P S FL E X I B L E M E TA L C O N D U I T G R O U N D G E N E R A L C O N TR A C TO R G E N E R A TO R G R O U N D F A U L T C I R C U I T I N TE R R U P TE R G R O U N D F A U L T P R O TE C T I O N H E A V Y D U TY H I G H I N TE N S I TY D I S C H A R G E H A N D -O F F -A U TO M A TI C H O R S E P O W E R H I G H P R E S S U R E S O D I U M H I G H V O L TA G E H E R TZ I S O L A T E D G R O U N D I N TE R M E D I A T E M E TA L C O N D U I T J U N C TI O N B O XVKVAkWkWhLEDLFMCLFNCLTGLVMAXM.C .M C A M C B M C C M D P M H M I N M L O M O C P N A N C N E C N E M A N F P A N I C N L N O N T S O C O H D R O L P B P P N L P T P T Z Q T Y R C P R M C R N C S C A S C B A S F S P D S P E C S W B D S W G R T L T P T T B T V T Y P U G U P S V V A V .I .F .V F D W A P W /W /O W P X F M RKILOVOLTKILOVOLT A M P E R E K I L O W A T T K I L O W A T T H O U R L I G H T E M I T T I N G D I O D E L I Q U I D T I G H T F L E X I B L E M E T A L C O N D U I T L I Q U I D T I G H T F L E X I B L E N O N M E T A L L I C C O N D U I T L I G H T I N G L O W V O L T A G E M A X I M U M M E C H . C O N T R A C T O R M I N I M U M C I R C U I T A M P S M A I N C I R C U I T B R E A K E R M O T O R C O N T R O L C E N T E R M A I N D I S T R I B U T I O N P A N E L M A N H O L E M I N I M U M M A I N L U G S O N L Y M A X I M U M O V E R C U R R E N T P R O T E C T I O N N O T A P P L I C A B L E N O R M A L L Y C L O S E D N A T I O N A L E L E C T R I C A L C O D E N A T I O N A L E L E C T R I C A L M A N U F A C T U R E R S A S S O C I A T I O N N A T I O N A L F I R E P R O T E C T I O N A S S O C I A T I O N N O T I N C O N T R A C T N I G H T L I G H T N O R M A L L Y O P E N N O T T O S C A L E O N C E N T E R O V E R H E A D D O O R O V E R L O A D P U S H B U T T O N P H A S E P A N E L P O T E N T I A L T R A N S F O R M E R P A N /T I L T /Z O O M Q U A N T I T Y R E F L E C T E D C E I L I N G P L A N R I G I D M E T A L C O N D U I T R I G I D N O N M E T A L L I C C O N D U I T S H O R T C I R C U I T A M P S S T A N D A R D C O L O R B Y A R C H I T E C T S Q U A R E F O O T (F E E T )S U R G E P R O T E C T I O N D E V I C E S P E C I F I C A T I O N S W I T C H B O A R D S W I T C H G E A R T W I S T L O C K T W I S T E D P A I R T E L E P H O N E T E R M I N A L B O A R D T E L E V I S I O N T Y P I C A L U N D E R G R O U N D U N I N T E R R U P T I B L E P O W E R S U P P L Y V O L T S V O L T A M P E R E V E R I F Y I N F I E L D V A R I A B L E F R E Q U E N C Y D R I V E W I R E L E S S A C C E S S P O I N T W I T H W I T H O U T W E A T H E R P R O O F T R A N S F O R M E R A . E .C . S H A L L R E F E R T O T H E M E C H A N I C A L D R A W I N G S F O R E X A C T L O C A T I O N S O F A L L M E C H A N I C A L E Q U I P M E N T A N D E L E C T R I C A L C O N N E C T I O N S . B . E .C . S H A L L P R O V I D E M I N I M U M W O R K I N G C L E A R A N C E A S P E R N E C B E F O R E I N S T A L L I N G A N Y E L E C T R I C A L P A N E L S O R C A B I N E T S . S E E E L E C T R I C A L E Q U I P M E N T C L E A R A N C E D E T A I L . C . I N S T A L L A L L L I G H T F I X T U R E S I N M E C H A N I C A L R O O M A F T E R T H E M E C H A N I C A L E Q U I P M E N T I S I N P L A C E . A D J U S T A S N E C E S S A R Y . P R O V I D E C H A I N S U S P E N S I O N K I T S A S R E Q U I R E D . D . R E F E R T O A R C H I T E C T U R A L R E F L E C T E D C E I L I N G P L A N (S ) F O R E X A C T F I X T U R E L O C A T I O N S , C E I L I N G T Y P E S , E T C . E . E .C . S H A L L P R O V I D E A L L C O N C R E T E P A D S A S R E Q U I R E D F O R A L L E L E C T R I C A L E Q U I P M E N T . F . C O N F I R M E X A C T L O C A T I O N S O F A L L T E L E P H O N E /D A T A O U T L E T S W I T H O W N E R P R I O R T O R O U G H -I N . G . L O C A T E S W I T C H E S , O U T L E T S , E T C ., S H O W N A T R O O M E N T R Y D O O R W A Y S , A S C L O S E T O D O O R F R A M E A S P O S S I B L E , S O A S N O T R O I N T E R F E R E W I T H R O O M C A B I N E T S , E T C . H . S U P P O R T A L L L I G H T F I X T U R E S I N D E P E N D E N T O F C E I L I N G . I . E L E C T R I C A L C O N T R A C T O R S H A L L O B T A I N A L L A P P L I C A B L E P E R M I T S F O R W O R K A N D P A Y A S S O C I A T E D F E E S . J . M A I N T A I N 2 4 " M I N . C L E A R A N C E F R O M A L L C O M M U N I C A T I O N S C A B L I N G A N D E L E C T R O N I C B A L L A S T S . K . U N L E S S S P E C I F I C A L L Y I N D I C A T E D O T H E R W I S E , E .C . S H A L L C O O R D I N A T E W I T H A N Y S P E C I A L S Y S T E M S S U P P L I E R /S H O P D R A W I N G S ; D E N T A L , M E D I C A L , K I T C H E N , S P E C I A L I Z E D E Q U I P M E N T , E T C . F O R T H E E X A C T R O U G H -I N R E Q U I R E M E N T S F O R T H E I R E Q U I P M E N T . A L S O U N L E S S I N D I C A T E D O T H E R W I S E , T H E E .C . T O B E R E S P O N S I B L E F O R F I N A L E L E C T R I C A L C O N N E C T I O N S T O A L L S P E C I A L E Q U I P M E N T . L . A L L C O N D U I T /R A C E W A Y /C A B L E S T O B E C O N C E A L E D I N W A L L S O R A B O V E C E I L I N G S . I F A N Y S U R F A C E W O R K I S N E C E S S A R Y , I T S H A L L B E A P P R O V E D B Y T H E A R C H I T E C T /E N G I N E E R P R I O R T O I N S T A L L A T I O N . M . E L E C T R I C A L C O N T R A C T O R S H A L L V I S I T T H E S I T E P R I O R T O B I D A N D T H O R O U G H L Y I N V E S T I G A T E T H E E X I S T I N G C O N D I T I O N S , A S T H E Y R E L A T E T O T H E S C O P E O F W O R K D E S C R I B E D . M A K E N E C E S S A R Y P R O V I S I O N S I N T H E B A S E B I D T O A D E Q U A T E L Y A C C O M M O D A T E T H E S E C O N D I T I O N S . N . D A T A C A B L I N G S Y S T E M P R E -I N S T A L L A T I O N C O N F E R E N C E : 1 . E .C . S H A L L S C H E D U L E A M E E T I N G A M I N I M U M O F F I V E C A L E N D A R D A Y S P R I O R T O B E G I N N I N G D A T A C A B L I N G I N S T A L L A T I O N . A T T E N D E E S S H O U L D I N C L U D E O W N E R ’S R E P ., E N G I N E E R , G C , E C A N D C A B L I N G S U B . R E F E R T O S E C T I O N 2 6 6 2 1 0 (1 .4 )(E ) F O R A D D I T I O N A L I N F O R M A T I O N . P R O J E C T G E N E R A L N O T E S : C O N T A C T : J a r o m T a y l o r N e x a n t (R o c k y M o u n t a i n P o w e r ) (8 0 1 ) 7 4 6 -1 6 2 3 F o r A s s i s t a n c e U T I L I T Y L I G H T I N G R E B A T E S & I N C E N T I V E S : I T S H A L L B E T H E R E S P O N S I B I L I T Y O F T H E E L E C T R I C A L C O N T R A C T O R T O P R E P A R E A L L R E Q U I R E D A P P L I C A T I O N S A N D I N F O R M A T I O N R E Q U I R E D T O P R O V I D E T H E O W N E R W I T H T H E M A X I M U M A M O U N T O F R E B A T E D O L L A R S F R O M T H E L O C A L U T I L I T Y C O M P A N Y . T H E E L E C T R I C A L C O N T R A C T O R S H A L L S U B M I T V E R I F I C A T I O N O F T H E U T I L I T Y C O M P A N Y P R E -A P P L I C A T I O N A P P R O V A L P R I O R T O O R D E R I N G A N Y M A T E R I A L S . V I S I T T H E F O L L O W I N G U T I L I T Y C O . W E B S I T E S F O R I N F O R M A T I O N : T Y P I C A L D E V I C E M O U N T I N G H E I G H T S : G E N E R A L C O O R D I N A T I O N N O T E : G E N E R A L D E T A I L N O T E S : F I N I S H F L O O R 1 ' - 6 '' T H E R M O S T A T O R S E N S O R V E R I F Y W I T H M .C . P R I O R T O L I G H T S W . (O R A S N O T E D ) * 4 ' - 0 '' * 3 ' - 6 '' (O R A S N O T E D ) R E C E P T A C L E @ M I L L W O R K B A C K S P L A S H C A B . D I M E N S I O N S P E R A R C H . D E T A I L 6 " C A B I N E T * E .C . S H A L L C O O R D I N A T E A L L D E V I C E M O U N T I N G H G T S . A N D E X A C T L O C A T I O N W I T H A R C H I T E C T U R A L I N T E R I O R E L E V A T I O N S R E P O R T C O N F L I C T S T O A R C H I T E C T **P R I O R T O R O U G H -I N ** R O U G H -I N . T Y P I C A L F O R A L L D E V I C E S M O U N T E D A B O V E C O U N T E R (i e C .O .'S , D A T A , P H O N E e t c .) A .B .C .D . A L L M O U N T I N G H E I G H T S T Y P I C A L U N L E S S N O T E D O T H E R W I S E . C O O R D I N A T E O U T L E T H E I G H T S W I T H A R C H I T E C T S M I L L W O R K D W G S . T O I N S U R E T H A T O U T L E T S W I L L N O T F A L L B E H I N D C A B I N E T S , B A C K S P L A S H E S , O R I N T E R F E R E W I T H W A I N S C O T I N G , E T C . A L L S W I T C H E S A N D T H E R M O S T A T S T O B E M O U N T E D A S C L O S E T O D O O R J A M S A S P O S S I B L E . C O O R D I N A T E A L L D E V I C E S W I T H A R C H I T E C T U R A L P L A N S A N D D E T A I L S . C O O R D I N A T E L I G H T S W I T C H & O U T L E T H E I G H T S W I T H A R C H I T E C T U R A L W A I N S C O T I N G A N D O R T I L E W O R K S O A S N O T T O F A L L M I D W A Y I N T H E S E F I N I S H E S . F I R E 6 ' - 8 '' F I R E A L A R M N O T I F I C A T I O N D E V I C E F I R E M A N U A L P U L L S T A T I O N H A N D L E S H A L L B E B E T W E E N 4 2 " & 4 8 " A F F C A B I N E T R E C E P T . T E L E /D A T A O U T L E T T V O U T L E T E L E C T R I C A L E Q U I P . C L E A R A N C E E L E C T R I C A L E Q U I P M E N T NOTE #1 N O T E #4NOTE#3 N O T E #2 N O T E S :1 . T H E M I N I M U M H E A D R O O M O F W O R K I N G S P A C E S H A L L B E 6 1 /2 F T .2 . T H E W I D T H O F T H E W O R K I N G S P A C E S H A L L B E T H E W I D T H O F T H E E Q U I P M E N T O R 3 0 ", W H I C H E V E R I S G R E A T E R . T H E P A N E L D O O R S H A L L O P E N A T L E A S T 9 0 D E G R E E S .3 . A L L C I R C U I T B R E A K E R S , W H E N I N T H I E R H I G H E S T P O S I T I O N , S H A L L N O T B E M O R E T H A N 6 F T 7 I N . A B O V E T H E F I N I S H E D F L O O R .4 . 3 F T C L E A R A N C E I F 0 -1 5 0 V T O G R O U N D , 3 .5 F T C L E A R A N C E I F 1 5 1 -6 0 0 V T O G R O U N D . 4 F T I F E X P O S E D L I V E P A R T S O N B O T H S I D E S O F T H E W O R K I N G S P A C E .G E N E R A L N O T E S :A . A L L W O R K I N G S P A C E C L E A R A N C E S A R E F R O M T H E F A C E O F T H E E Q U I P M E N T .8 2 7 0 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E . C e n t e r P o c a t e l l o , I d a h o 8 3 2 0 1 t e l (2 0 8 ) 2 3 2 -4 4 3 9 w w w .p a y n e e n g i n e e r i n g i n c .c o mEngineering I n c .C o n s u l t i n g E n g i n e e r s3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 s h e e t :t i t l e :r e v i s i o n s :p r o j e c t # :d a t e :U N L E S S A P R O F E S S I O N A L S E A L W I T H S I G N A T U R E A N D D A T E I S A F F I X E D , T H I S D O C U M E N T I S P R E L I M I N A R Y A N D I S N O T I N T E N D E D F O R C O N S T R U C T I O N , R E C O R D I N G P U R P O S E S , O R I M P L E M E N T A T I O N T H E D E S I G N S S H O W N A N D D E S C R I B E D H E R E I N I N C L U D I N G A L L T E C H N I C A L D R A W I N G S , G R A P H I C R E P R E S E N T A T I O N S & M O D E L S T H E R E O F , A R E P R O P R I E T A R Y & C A N N O T B E C O P I E D , D U P L I C A T E D , O R C O M M E R C I A L L Y E X P L O I T E D I N W H O L E O R I N P A R T W I T H O U T T H E S O L E A N D E X P R E S S W R I T T E N P E R M I S S I O N F R O M M E T H O D S T U D I O I N C .p r o j e c t : E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P .E . #:2 2 1 2 7 0 4 -2 8 -2 0 2 3 E G 0 .0ELECTRICALSYMBOLS &D E T A I L S22.0 5 4 0 0 4 /2 8 /2 0 2 3[ S E T P R O J E C T I N F O R M A T I O N A D D R E S S T E X T F I E L D A N D S E T L O C A T I O N U N D E R E N E R G Y S E T T I N G S I F A P P L I CA B L E ]R o m n e y 2 0 2 3 R e m o d e l S E C U R I T Y & A C C E S S C O N T R O L S Y M B O L S C H E D U L E N O T E : A L L S Y M B O L S M A Y N O T B E U S E D S Y M B O L D E S C R I P T I O N C A R D R E A D E R /K E Y P A D L O C A T I O N ; U T I L I Z E 4 S Q . B O X W /1 -G A N G M U D R I N G A N D 3 /4 "C . W / P U L L S T R I N G T O N E A R E S T A C C E S S I B L E C E I L I N G S P A C E . C R C A M S E C U R I T Y C A M E R A : P R O V I D E A N D I N S T A L L A 4 S Q . B O X W /3 /4 "C ., T O N E A R E S T A C C E S S I B L E C E I L I N G S P A C E & 1 -C A T 6 A C A B L E T O I T R O O M . T E R M I N A T E J A C K O N T H E C A B L E F O R C A M E R A . C A M E R A T O B E P R O V I D E D A N D I N S T A L L E D B Y O W N E R O V E R B O X ; C O O R D I N A T E R O U G H -I N W I T H O W N E R C A M E R A S P E C . C O N N E C T I O N T O D O O R F R A M E F O R A C C E S S C O N T R O L . P R O V I D E (1 )3 /4 "C W /P U L L S T R I N G F R O M D O O R T O N E A R E S T A C C E S S S I B L E C E I L I N G S P A C E . • E .C . I S R E S P O N S I B L E F O R R O U G H -I N F O R A C C E S S C O N T R O L S Y S T E M ; E Q U I P M E N T A N D C A B L I N G T O B E P R O V I D E D A N D I N S T A L L E D B Y O W N E R . E .C . S H A L L C O O R D I N A T E R O U G H -I N O F A C C E S S C O N T R O L S Y S T E M W I T H B Y U -I P R I O R T O R O U G H -I N . • E .C . I S R E S P O N S I B L E F O R R O U G H -I N , C A B L I N G A N D T E R M I N A T I O N S F O R S E C U R I T Y C A M E R A 'S . C A M E R A S W I L L B E P R O V I D E D A N D I N S T A L L E D B Y B Y U -I . E .C . S H A L L C O O R I N A T E L O C A T I O N S A N D R O U G H -I N W I T H B Y U -I P R I O R T O W O R K B E I N G D O N E . G E N E R A L S E C U R I T Y & A C C E S S C O N T R O L N O T E S : F C 1 2 " S Q U A R E , S E M I -R E C E S S E D 6 0 H Z . S Y N C H R O N O U S , 4 -W I R E C L O C K W I T H A L U M I N U M F R A M E A N D W H I T E F A C E . S I M P L E X #2 3 1 0 -9 2 7 1 W / S I M P L E X #2 9 7 5 -9 0 3 8 R E C E S S E D B A C K B O X . (U N O ) M - M A S T E R C L O C K (A M E R I C A N T I M E & S T A N D A R D #A S Q M S T R -0 0 2 X E ) D - D I G I T A L C L O C K (A M E R I C A N T I M E & S T A N D A R D #C C 4 S E ) P R O V I D E A N D I N S T A L L A 3 /4 "C ., 4 #1 2 T H H N (B L K ,W H T ,R E D ,G R N ) F R O M E A C H C L O C K B A C K T O N E A R E S T M A S T E R C L O C K O R S Y S T E M J -B O X . P R O V I D E A L L R E Q U I R E D C O N N E C T I O N S B E T W E E N M A S T E R C L O C K A N D C L O C K S F O R A C O M P L E T E A N D F U N C T I O N A L S Y S T E M . A B C D E F G H 3 4 5 6 7 8 1 2 1 2 1 1 2 2 3 1 1 2 2 1 1 2 2 1 1 2 2 4 4 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 ED1.0LEVEL 0 EXISTING LIGHTING PLAN22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 RemodelA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 D I S C O N N E C T A N D R E M O V E E X I S T I N G R E C E S S E D C A N MAINTAIN CIRCUIT FOR NEW LIGHT.2 P R O V I D E A N D I N S T A L L A M E T A L P L A T E T O C O V E R E X I S T I N G OPENING. PLATE SHALL BE CUT TO ACCEPT NEW SYLVANIA LED/RT8/2000/840 LED DOWN LIGHT. METAL PLATE FINISH TO MATCH SOFFIT. PROVIDE AND INSTALL LIGHT FIXTURE CONNECT TO EXISTING CIRCUIT AND CONTROLS.3 N E W L I G H T I N G F I X T U R E . C U T E X I S T I N G S O F F I T T O A C C E P T NEW SYLVANIA LED/RT8/2000/840 CONNECT TO EXISTING EXTERIOR LIGHTING CIRCUIT AND CONTROLS.4 D I S C O N N E C T A N D R E M O V E E X I S T I N G L I G H T I N G I N A R E A . REMOVE ALL ASSOCIATED CONDUIT, CABLE, AND CONTROLS.KEY NOTES:# NO R T H 16 ' 8' 0" SC A L E : 1 / 8 " = 1 ' - 0 " 1 LE V E L 0 E X I S T I N G L I G H T I N G P L A N 1. ALL CIRCUIT BREAKERS FROM DEMOLITIONED PANELS SHALL BE BOXED UP AND DELIVERED TO THE OWNER, TO AN ON CAMPUS LOCATION AS DIRECTED BY OWNER. 2. ALL CONDUCTORS BEING REMOVED THAT ARE RATED 100 AMPS AND ABOVE SHALL BE DELIVERED TO THE CAMPUS RECYCLING CENTER.3. ALL TRANSFORMERS BEING REMOVED SHALL BE DELIVERE D TO THE OWNER, TO AN ON CAMPUS LOCATION AS DIRECTED BY OWNER.4. UNLESS INDICATED ABOVE, ALL OTHER MATERIAL SHALL BE DISPOSED OF LEGALLY BY THE CONTRACTOR. SPECIAL DEMOLITION NOTES:A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERW ISE, ALL EXISTING ELECTRICAL EQUIPMENT SHOWN SHALL BE REMOVED. WHEN EXISTING SWITCH AND OR OUTLET BOXES FALL WITHIN OR NEAR NEW OUTLETS/SWITCHES SHOWN IN NEW DESIGN, THE E.C. MAY UTILIZE THE EXISTING ROUGH -IN, ETC. IN LIEU OF INSTALLING NEW. CONTRACTOR MUST HOWEVER MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. ELECTRICAL CONTRACTOR MAY UTILIZE ANY EXISTING RACEWAYS WHERE THEY ARE COMPATIBLE WITH NEW DESIGN/SYSTEMS. PROVIDE ALL NEW DEVICES AND COVERS.B. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS, HOWEVER THE ABOVE INFORMATION APPLIES.C. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED SWITCH/OUTLET/J-BOXES WHERE REQUIRED.D. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SH ALL BE ADAPTED TO NEW WALL COVERINGS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS, ETC.E. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH THE OWNER.F. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION, DETAILS, ETC.G. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK.H. WHERE EXISTING CIRCUITS ARE TO BE RE-USED, EXTEN D AS NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN.I. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE-INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION OF EXISTING CIRCUITS OR WIRING.J. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANIC AL EQUIPMENT TO BE REMOVED OR RELOCATED.K. REMOVE ALL UNUSED EQUIPMENT WIRING, CONDUIT AND BOXES IN ALL AREAS. ABANDON ONLY IN CONCEALED AREAS.L. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITIO N AND COMPLIES WITH SPECIFICATIONS.M. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS.N. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT USED IN FINISHED AREAS.GENERAL NOTES: FB FB F B FB P P P P P P P P P P F F A B C D E F G H J 3 4 5 6 7 8 'R R ' 'S ' 'R ' 'F A C P ' 1 2 2 3 3 4 4 2 2 1 1 1 1 1 1 5 5 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 ED1.1LEVEL 0 EXISTING POWER PLAN22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 RemodelA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 E X I S T I N G D E V I C E L O C A T I O N T O R E M A I N . R E L A C E D E V I C E AND FACEPLATE. PROVIDE NEW CIRCUIT AS SHOWN.2 C A R E F U L L Y D I S C O N N E C T , R E M O V E , A N D C L E A N E X I S T I N G SECURITY CAMERA. REMOVE ALL ASSOCIATED CONDUIT AND CABLE. RETURN CAMERA TO OWNER.3 C A R E F U L L Y D I S C O N N E C T , R E M O V E , C L E A N A N D S T O R E EXISTING CLOCK TO BE USED IN REMODEL. RETURN ALL UNUSED CLOCKS TO OWNER.4 C A R E F U L L Y R E M O V E E X I S T I N G P A N E L . P R O T E C T A N D S T O R E PANEL INTERIOR FOR POSSIBLE USE IN NEW DESIGN, IF N EW PANELS ARE NOT AVAILABLE TO MEET CONSTRUCTION TIMELINES. DISCONNECT AND REMOVE EXISTING FEEDER CONDUCTORS AND CONDUIT WHERE ACCESSIBLE. SEE SPECIAL DEMO NOTE FOR FURTHER INSTRUCTION.5 E . C . S H A L L I N T E R C E P T A L L E X I S T I N G C I R C U I T S T O R E M A IN.SLICE AND EXTEND TO NEW PANEL LOCATION AND TERMINATE ON NEW BREAKERS LABEL EACH SPLICED CIRCUIT.KEY NOTES:# SC A L E : 1 / 8 " = 1 ' - 0 " 1 LE V E L 0 E X I S T I N G P O W E R P L A N NO R T H 16 ' 8' 0" A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERW ISE, ALL EXISTING ELECTRICAL EQUIPMENT SHOWN SHALL BE REMOVED. WHEN EXISTING SWITCH AND OR OUTLET BOXES FALL WITHIN OR NEAR NEW OUTLETS/SWITCHES SHOWN IN NEW DESIGN, THE E.C. MAY UTILIZE THE EXISTING ROUGH -IN, ETC. IN LIEU OF INSTALLING NEW. CONTRACTOR MUST HOWEVER MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. ELECTRICAL CONTRACTOR MAY UTILIZE ANY EXISTING RACEWAYS WHERE THEY ARE COMPATIBLE WITH NEW DESIGN/SYSTEMS. PROVIDE ALL NEW DEVICES AND COVERS.B. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS, HOWEVER THE ABOVE INFORMATION APPLIES.C. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED SWITCH/OUTLET/J-BOXES WHERE REQUIRED.D. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SH ALL BE ADAPTED TO NEW WALL COVERINGS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS, ETC.E. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH THE OWNER.F. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION, DETAILS, ETC.G. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK.H. WHERE EXISTING CIRCUITS ARE TO BE RE-USED, EXTEN D AS NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN.I. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE-INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION OF EXISTING CIRCUITS OR WIRING.J. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANIC AL EQUIPMENT TO BE REMOVED OR RELOCATED.K. REMOVE ALL UNUSED EQUIPMENT WIRING, CONDUIT AND BOXES IN ALL AREAS. ABANDON ONLY IN CONCEALED AREAS.L. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITIO N AND COMPLIES WITH SPECIFICATIONS.M. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS.N. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT USED IN FINISHED AREAS.GENERAL NOTES:1. ALL CIRCUIT BREAKERS FROM DEMOLITIONED PANELS SHALL BE BOXED UP AND DELIVERED TO THE OWNER, TO AN ON CAMPUS LOCATION AS DIRECTED BY OWNER. 2. ALL CONDUCTORS BEING REMOVED THAT ARE RATED 100 AMPS AND ABOVE SHALL BE DELIVERED TO THE CAMPUS RECYCLING CENTER.3. ALL TRANSFORMERS BEING REMOVED SHALL BE DELIVERE D TO THE OWNER, TO AN ON CAMPUS LOCATION AS DIRECTED BY OWNER.4. UNLESS INDICATED ABOVE, ALL OTHER MATERIAL SHALL BE DISPOSED OF LEGALLY BY THE CONTRACTOR. SPECIAL DEMOLITION NOTES: C A 1 B C D E F 2 3 4 5 HA Z . ST O R A G E [1 6 7 ] HA Z . ST O R A G E [1 6 6 ] RO C K LA B O R A T O R Y [1 6 4 ] ME N ' S T . R . [1 6 2 ] WO M E N ' S T. R . [1 6 0 ] PI P E CH A S E [I - Q ] HA L L W A Y [1 - T ] LA B P R E P RO O M [1 6 1 ] EL E V A T O R [1 - M ] CU S T . [1 4 7 ] ST A I R W E L L [1 - P ] PH Y S I C A L GE O L O G Y RO O M [1 5 8 ] WO M E N ' S RM [1 3 2 ] ME N ' S R M [1 3 4 ] LE C T U R E HA L L [1 4 5 ] PR E P / S T O R A G E RM [1 4 3 ] MI N E R O L O G Y LA B [1 4 9 ] HA L L W A Y [I - N ] HA L L W A Y [I - L ] HA L L W A Y [I - K ] UN I S E X R M [1 3 6 ] HA L L W A Y [1 - U ] ST A I R W E L L [1 - V ] BD F [1 3 8 ] ST A I R W E L L [1 - S ] EL E V A T O R [1 - J ] 1 1 1 1 2 2 2 2 3 3 3 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 ED1.2LEVEL 1 EXISTING ELECTRICAL PLAN22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 RemodelA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 D I S C O N N E C T A N D R E M O V E E X I S T I N G R E C E S S E D C A N MAINTAIN CIRCUIT FOR NEW LIGHT.2 P R O V I D E A N D I N S T A L L A M E T A L P L A T E T O C O V E R E X I S T I N G OPENING. PLATE SHALL BE CUT TO ACCEPT NEW SYLVANIA LED/RT8/2000/840 LED DOWN LIGHT. METAL PLATE FINISH TO MATCH SOFFIT. PROVIDE AND INSTALL LIGHT FIXTURE CONNECT TO EXISTING CIRCUIT AND CONTROLS.3 E . C . S H A L L P R O T E C T , M A I N T A I N A N D / O R R E - E S T A B L I S H A LL EXISTING LIGHTING, CONTROLS, FIRE ALARM AND POWER I N THIS AREA.KEY NOTES:# SC A L E : 1 / 8 " = 1 ' - 0 " 1 LE V E L 1 E X I S T I N G P L A N 16 ' 8' 0" NO R T H A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERW ISE, ALL EXISTING ELECTRICAL EQUIPMENT SHOWN SHALL BE REMOVED. WHEN EXISTING SWITCH AND OR OUTLET BOXES FALL WITHIN OR NEAR NEW OUTLETS/SWITCHES SHOWN IN NEW DESIGN, THE E.C. MAY UTILIZE THE EXISTING ROUGH -IN, ETC. IN LIEU OF INSTALLING NEW. CONTRACTOR MUST HOWEVER MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. ELECTRICAL CONTRACTOR MAY UTILIZE ANY EXISTING RACEWAYS WHERE THEY ARE COMPATIBLE WITH NEW DESIGN/SYSTEMS. PROVIDE ALL NEW DEVICES AND COVERS.B. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS, HOWEVER THE ABOVE INFORMATION APPLIES.C. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED SWITCH/OUTLET/J-BOXES WHERE REQUIRED.D. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SH ALL BE ADAPTED TO NEW WALL COVERINGS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS, ETC.E. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH THE OWNER.F. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION, DETAILS, ETC.G. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK.H. WHERE EXISTING CIRCUITS ARE TO BE RE-USED, EXTEN D AS NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN.I. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE-INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION OF EXISTING CIRCUITS OR WIRING.J. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANIC AL EQUIPMENT TO BE REMOVED OR RELOCATED.K. REMOVE ALL UNUSED EQUIPMENT WIRING, CONDUIT AND BOXES IN ALL AREAS. ABANDON ONLY IN CONCEALED AREAS.L. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITIO N AND COMPLIES WITH SPECIFICATIONS.M. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS.N. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT USED IN FINISHED AREAS.GENERAL NOTES:1. ALL CIRCUIT BREAKERS FROM DEMOLITIONED PANELS SHALL BE BOXED UP AND DELIVERED TO THE OWNER, TO AN ON CAMPUS LOCATION AS DIRECTED BY OWNER. 2. ALL CONDUCTORS BEING REMOVED THAT ARE RATED 100 AMPS AND ABOVE SHALL BE DELIVERED TO THE CAMPUS RECYCLING CENTER.3. ALL TRANSFORMERS BEING REMOVED SHALL BE DELIVERE D TO THE OWNER, TO AN ON CAMPUS LOCATION AS DIRECTED BY OWNER.4. UNLESS INDICATED ABOVE, ALL OTHER MATERIAL SHALL BE DISPOSED OF LEGALLY BY THE CONTRACTOR. SPECIAL DEMOLITION NOTES: S nD 1 S nD 1 S nD 1 S nD 1 1 C D E F 2 3 4 5 3 3 3 (T Y P ) (T Y P ) (T Y P ) 3 (T Y P ) 4 4 4 1 C D E F 2 3 4 5 1 1 1 1 1 1 111 2 5 6 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 ED2.2LEVEL 2 EXISTING ELECTRICAL PLAN22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 RemodelA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 E X I S T I N G D E V I C E L O C A T I O N T O R E M A I N . R E L A C E D E V I C E AND FACEPLATE. PROVIDE NEW CIRCUIT AS SHOWN.2 C A R E F U L L Y D I S C O N N E C T , R E M O V E , C L E A N A N D S T O R E EXISTING CLOCK TO BE USED IN REMODEL. RETURN ALL UNUSED CLOCKS TO OWNER.3 C A R E F U L L Y D I S C O N N E C T , R E M O V E , A N D C L E A N E X I S T I N G LIGHTING IN THIS AREA; REMOVE ALL ASSOCIATED CONTROLS, WIRE AND CONDUIT, MAINTAIN EXISTING NORMA L AND EMERGENCY LIGHTING CIRCUITS FOR NEW LIGHTING.MAINTAIN AND/OR RE-ESTABLISH ELECTRICAL CONTINUITY TO DOWNSTREAM DEVICES TO REMAIN. LIGHTING CONTROL DEVICES THAT ARE COMPATIBLE WITH NEW DESIGN MAY BE REUSED. RETURN ANY LIGHTING FIXTURE THAT IS NOT RE-INSTALLED TO OWNER.4 E . C . S H A L L P R O T E C T , M A I N T A I N A N D / O R R E - E S T A B L I S H A LL EXISTING LIGHTING, CONTROLS, FIRE ALARM AND POWER I N THIS AREA.5 C A R E F U L L Y R E M O V E E X I S T I N G P A N E L . P R O T E C T A N D S T O R E PANEL INTERIOR FOR POSSIBLE USE IN NEW DESIGN, IF N EW PANELS ARE NOT AVAILABLE TO MEET CONSTRUCTION TIMELINES. DISCONNECT AND REMOVE EXISTING FEEDER CONDUCTORS AND CONDUIT WHERE ACCESSIBLE. SEE SPECIAL DEMO NOTE FOR FURTHER INSTRUCTION.6 E . C . S H A L L I N T E R C E P T A L L E X I S T I N G C I R C U I T S T O R E M A IN.SLICE AND EXTEND TO NEW PANEL LOCATION AND TERMINATE ON NEW BREAKERS LABEL EACH SPLICED CIRCUIT.KEY NOTES:# SC A L E : 1 / 8 " = 1 ' - 0 " 1 LE V E L 2 E X I S T I N G L I G H T I N G P L A N SC A L E : 1 / 8 " = 1 ' - 0 " 2 LE V E L 2 E X I S T I N G P O W E R P L A N 16 ' 8' 0" NO R T H 16 ' 8' 0" NO R T H 1. ALL CIRCUIT BREAKERS FROM DEMOLITIONED PANELS SHALL BE BOXED UP AND DELIVERED TO THE OWNER, TO AN ON CAMPUS LOCATION AS DIRECTED BY OWNER. 2. ALL CONDUCTORS BEING REMOVED THAT ARE RATED 100 AMPS AND ABOVE SHALL BE DELIVERED TO THE CAMPUS RECYCLING CENTER.3. ALL TRANSFORMERS BEING REMOVED SHALL BE DELIVERE D TO THE OWNER, TO AN ON CAMPUS LOCATION AS DIRECTED BY OWNER.4. UNLESS INDICATED ABOVE, ALL OTHER MATERIAL SHALL BE DISPOSED OF LEGALLY BY THE CONTRACTOR. SPECIAL DEMOLITION NOTES:A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERW ISE, ALL EXISTING ELECTRICAL EQUIPMENT SHOWN SHALL BE REMOVED. WHEN EXISTING SWITCH AND OR OUTLET BOXES FALL WITHIN OR NEAR NEW OUTLETS/SWITCHES SHOWN IN NEW DESIGN, THE E.C. MAY UTILIZE THE EXISTING ROUGH -IN, ETC. IN LIEU OF INSTALLING NEW. CONTRACTOR MUST HOWEVER MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. ELECTRICAL CONTRACTOR MAY UTILIZE ANY EXISTING RACEWAYS WHERE THEY ARE COMPATIBLE WITH NEW DESIGN/SYSTEMS. PROVIDE ALL NEW DEVICES AND COVERS.B. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS, HOWEVER THE ABOVE INFORMATION APPLIES.C. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED SWITCH/OUTLET/J-BOXES WHERE REQUIRED.D. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SH ALL BE ADAPTED TO NEW WALL COVERINGS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS, ETC.E. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH THE OWNER.F. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION, DETAILS, ETC.G. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK.H. WHERE EXISTING CIRCUITS ARE TO BE RE-USED, EXTEN D AS NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN.I. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE-INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION OF EXISTING CIRCUITS OR WIRING.J. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANIC AL EQUIPMENT TO BE REMOVED OR RELOCATED.K. REMOVE ALL UNUSED EQUIPMENT WIRING, CONDUIT AND BOXES IN ALL AREAS. ABANDON ONLY IN CONCEALED AREAS.L. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITIO N AND COMPLIES WITH SPECIFICATIONS.M. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS.N. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT USED IN FINISHED AREAS.GENERAL NOTES: C SnD1 S nD 1 nD nD C nD C S CD 1 S CD 1 S CD 1 S CD 1 n D n1 nD nD nD S nD 1 S nD 1 S nD 1 WD 1 WD 1 n2 D n 2 D S nD 1 S nD 1 R nP S 8 0 R nP S 8 0 WD1 nD S nD 1 n D O n2D S nD1 S nD1 S nD 1 S nD1SnD1 S nD 1 S nD 1 S nD 1 S nD 1 S nD 1 nD S nD 1 S nD 1 W D 1 S CD 1 S CD 2 S CD 2 W D 1 nD D R n P P 1 6 nD RnPP16 S nD 1 A B C D E F G 3 4 5 6 7 ME N ' S R M [6 6 ] WO M E N ' S RM [6 4 ] ME C H A N I C A L RO O M [6 9 ] VE S T I B U L E [O - A ] HA L L W A Y [O - C ] ST O R A G E [6 3 ] ST A I R W E L L [O - B ] PI P E CH A S E [O - Q ] EL E V A T O R [O - D ] ME C H R M [6 7 ] CU S T R M [6 8 ] CLASSROOM [50] DA R K RO O M [5 9 D ] CO M P U T E R LA B [5 9 ] PH O T O ST U D I O [5 1 ] VE S T I B U L E [5 9 C ] OF F I C E [5 7 ] EQ U I P / CH E C K O U T [5 9 A ] ST O R A G E [5 9 B ] OF F I C E [5 5 ] FI L M [5 9 E ] AC O U S T I C S ST U D I O [5 2 B ] ST O R A G E [5 1 A ] CH A N G I N G [5 1 B ] VESTIBULE [0-H] OP T I C S L A B [5 2 A ] PHYSICS LAB [52]STORAGE [52C] (T Y P ) F3 (T Y P ) F3 (T Y P ) F4 (T Y P ) F4 b b b b bb b a aa a a aa a a (T Y P ) F1 2 (T Y P ) F3 (T Y P ) F3 (T Y P ) (T Y P ) F3 (T Y P ) F3 (T Y P ) F3 (TYP)F3 F3 F3 (TYP)F3F3F3F3 F3 F3 F3 F3 F3 F3 F6 F4 'S ' 'R''R(SEC 2)' S -29 S -27 R -53 (T Y P ) F3 (TYP)F3 F3E F3EF3E F3 E F3E F3 E (TYP)F3 F3 E F3 E F3 E F3E F3EF3E F3 E F3 E F3 E F3 E F3 E F3 E F3E F3E F1 0 F1 0 F3 A EE 1 . 0 1 F1 0 F1 0 F1 2 F1 2 F1 2 F1 2 F3 F3 F1 F1 F1 2 F1 2 F1 R -52 F1 1 F11 R -54 S -32 (T Y P ) F9 F9 F1 2 E F1 2 E F1 2 E F1 2 E F1 2 E F1 2 E F1 2 E F1 2 E R -51 (T Y P ) F1 2 (T Y P ) F1 2 2 3 3 (T Y P ) (T Y P ) F1 3 F1 3 F7 F8 F8 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 EE1.0LEVEL 0 LIGHTING PLAN22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 RemodelA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 DIMMING SWITCH TO CONTROL VANITY LIGHTS. CIRCUIT DOWN STREAM FROM WALL OCC SENSOR.2 S U S P E N D 1 " U N I S T R U T T O H E I G H T S P E C I F I E D B Y A R C H I T E CT AND MOUNT TRACK TO SUSPENDED STRUT.3 S U S P E N D F I X T U R E W I T H A I R C R A F T C A B L E . C O O R D I N A T E SUSPENSION HEIGH AND LIGHT LOCATION WITH OTHER CEILING DEVICES AND WITH OWNER AND ARCHITECT PRIOR TO ROUGH IN.KEY NOTES:# NO R T H 16 ' 8' 0" SC A L E : 1 / 8 " = 1 ' - 0 " 1 LE V E L 0 O V E R A L L L I G H T I N G P L A N LI G H T I N G C O N T R O L ( n L I G H T ) S Y S T E M S C H E D U L E TY P E D E S C R I P T I O N M F G R . C A T A L O G # N O T E S CE I L I N G S E N S O R S nD 1 D U A L - T E C H N O L O G Y , S M A L L M O T I O N , C E I L I N G OC C U P A N C Y S E N S O R W / A U T O D I M M I N G C O N T R O L PH O T O C E L L SE N S O R S W I T C H n C M - P D T - 9 - R J B - AD C X RE L A Y P A C K S / P O W E R S U P P L I E S & I N T E R F A C E D E V I C E S nP P 1 6 R E L A Y P O W E R P A C K SE N S O R S W I T C H n P P 1 6 2 nP S 8 0 R E L A Y P O W E R P A C K SE N S O R S W I T C H n P S 8 0 2 WA L L S W I T C H E S nL I G H T O N / O F F P U S H B U T T O N S E N S O R S W I T C H n P O D M 3 n1 n L I G H T O N / O F F P U S H B U T T O N S E N S O R S W I T C H n P O D M 3 n2 D n L I G H T O N / O F F P U S H B U T T O N W / D I M M I N G , 2- C H A N N E L SE N S O R S W I T C H n P O D M - 2 P D X - X 3 nD n L I G H T O N / O F F P U S H B U T T O N W / D I M M I N G S E N S O R S W I T C H n P OD M - D X 3 nD C n L I G H T O N / O F F P U S H B U T T O N W / D I M M I N G , C O L O R CO R R E C T I O N SE N S O R S W I T C H n P O D M - D X - C C T 3 nD O n L I G H T D U A L - T E C H O C C U P A N C Y S E N S O R , O N / O F F PU S H B U T T O N W / D I M M I N G SE N S O R S W I T C H n W S X P D T L V - D X 3 LI G H T I N G F I X T U R E S C H E D U L E TY P E D E S C R I P T I O N M O U N T I N G V O L T S L U M E N S CO L O R TE M P . ( K ) MF G R . C A T A L O G # N O T E S F1 E X I T S I G N WA L L O R CE I L I N G 12 0 - 2 7 7 N / A N / A L I T H O N I A L Q M - S - W - 3 - G - 1 2 0 / 2 7 7 - A C 11 F2 E X I S T I N G 2 X 2 L A Y - I N F I X T U R E R E C E S S E D 1 2 0 - 2 7 7 4 0 0 0 4 0 0 0 12 F3 2 X 2 L A Y - I N L E D , 0 - 1 0 V D I M M I N G R E C E S S E D 1 2 0 - 2 7 7 4 0 0 0 4 00 0 L I T H O N I A E P A N L - 2 X 2 - 4 8 0 0 - L M - 8 0 C R I - 4 0 K - M I N 1 - N L I G H T - MV O LT F4 2 X 2 L A Y - I N L E D C O L O R C O R R E C T I N G R E C E S S E D 1 2 0 - 2 7 7 4 0 0 0 4 0 0 0 L I T H O N I A 2 B L T 2 - T U W H - P R O P - 4 8 L - A D S M - M V O L T - N L T F5 6 " R O U N D R E C E S S E D L E D C A N , 0 - 1 0 V DI M M I N G RE C E S S E D 1 2 0 - 2 7 7 1 5 0 0 4 0 0 0 L I T H O N I A L D N 6 - 4 0 / 1 5 - L O 6 A R - L S S -M V O L T - E Z 1 0 F6 " I N U S E " L I G H T WA L L 1 2 0 - 2 7 7 RT T E C H N O L O G I E S L E D S - S J - 1 1 0 - R - 1 U F7 2 4 " V A N I T Y M A K E U P L I G H T S U R F A C E 1 2 0 - 2 7 7 KI C H L E R 6 2 4 N I F8 3 6 " V A N I T Y M A K E U P L I G H T S U R F A C E 1 2 0 - 2 7 7 KI C H L E R 6 2 6 N I F9 R E C E S S E D C A N W / I N C A D E S C E N T B U L B R E C E S S E D 1 2 0 - 2 7 7 LI T H O N I A L 7 X R 6 / C O 1 R 6 1 0 0 W R 4 0 I N C F1 0 4 F T L E D S T R I P , 0 - 1 0 V D I M M I N G S U R F A C E / SU S P E N D E D 12 0 - 2 7 7 4 0 0 0 4 0 0 0 L I T H O N I A C L X - L 4 8 - 4 0 0 0 L M - S E F - R D L - M V O L T -G Z 1 0 - 4 0 K - 8 0 C R I F1 1 L E D T R A C K L I G H T S U R F A C E 1 2 0 1 5 0 0 4 0 0 0 L S I T R A C K : T R K - S C- X X 1 - 1 2 0 - C B A H E A D S E E N O T E 9 1 0 F1 2 1 X 4 S U R F A C E F I X T U R E S U R F A C E 1 2 0 - 2 7 7 4 0 0 0 4 0 0 0 L I T H O N I A B L W P 4 - 4 0 L - A D P - E Z 1 - L P 8 4 0 - N 1 0 0 F1 3 H A I R L I G H T F L A S H U N I T 12 0 EI N S T E I N E 6 4 0 8 LI G H T I N G C O N T R O L / O C C U P A N C Y S E N S O R S C H E D U L E TY P E D E S C R I P T I O N MF G R . C A T A L O G # AP P R O V E D EQ U A L S N O T E S OC C . S E N S O R S - C E I L I N G ( L I N E V O L T A G E ) CD 2 D U A L - T E C H N O L O G Y , L I N E V O L T A G E , S M A L L M O T I O N 8 0 0 W M A X LO A D SE N S O R S W I T C H C M R P D T 9 C O O P E R , WA T T S O P P E R , HU B B E L L OC C . S E N S O R S - C E I L I N G ( L O W V O L T A G E ) CD 1 D U A L - T E C H N O L O G Y , S M A L L M O T I O N 3 6 0 D E G R E E C O V E R A G E, LO W V O L T A G E , W / I S O L A T E D R E L A Y SE N S O R S W I T C H C M P D T 9 R C O O P E R , WA T T S T O P P E R , HU B B E L L 1 OC C . S E N S O R S - W A L L M O U N T E D WD 1 D U A L - T E C H N O L O G Y , 1 - P O L E , N E U T R A L R E Q U I R E D S E N S O R SW I T C H W S X P D T - * * C O O P E R , WA T T S T O P P E R , HU B B E L L 2 1. R E F E R T O D R A W I N G S F O R F I X T U R E S R E Q U I R E D T O H A V E 0- 1 0 V O R S T E P - L E V E L D I M M I N G C O N T R O L . P R O V I D E F I X T U R E( S ) W I T H L E D D R I V E R ( S ) AN D R E Q U I R E D D I M M I N G / S W I T C H - L E G C O N D U C T O R S B E T W E E N SW I T C H ( E S ) A N D F I X T U R E ( S ) T O P R O V I D E C O N T R O L A S I N D IC A T E D O N DR A W I N G S . 2. F I X T U R E T O B E C O N T I N U O U S R O W M O U N T E D , L E N G T H A S IN D I C A T E D O N D R A W I N G S . P R O V I D E R E Q U I R E D A C C E S S O R I E S /C O N N E C T O R S F O R CO N T I N U O U S R O W M O U N T I N G . 3. S C B A - S T A N D A R D C O L O R B Y A R C H I T E C T / O W N E R ( C O O R D I N AT E C O L O R W I T H A R C H I T E C T / O W N E R P R I O R T O O R D E R I N G . ) 4. F I E L D A D J U S T P E N D A N T L E N G T H A S R E Q U I R E D , V E R I F Y LE N G T H W I T H C O U N T E R A S D I R E C T E D B Y A R C H I T E C T . 5. R E F E R T O A R C H I T E C T U R A L E L E V A T I O N D R A W I N G S F O R P L AC E M E N T A N D M O U N T I N G H E I G H T O F F I X T U R E S . 6. P R O V I D E A N D I N S T A L L 1 2 0 V F A C T O R Y A P P R O V E D D I M M E R S W I T C H F O R T R A C K : A C U I T Y P / N : S Y N E R G Y I S D 4 0 0 E L V 12 0 . 7. P R O V I D E A L L C O M P O N E N T S F O R C O M P L E T E I N S T A L L A T I O N , I N C L U D I N G B U T N O T L I M I T E D T O : E N D F E E D S , C O N N E C T O RS A N D E T C . 8. M O U N T P E R M A N U F A C T U R E A N D O W N E R . M A K E A L L R E Q U I R ED C O N N E C T I O N S . 9. E . C . S H A L L P R O V I D E A N D I N S T A L L ( 2 0 ) L Z - 1 5 - 9 0 - 4 0 - ZM - C T 2 - 1 0 - 1 2 0 - C B A . L O C A T E D , A I M , A N D F O C U S T O S A T I S FA C T I O N O F O W N E R . 10 . R E F E R T O P L A N S F O R T R A C K L E N G T H A N D C O N F I G U R A T I ON . E . C . S H A L L P R O V I D E A N D I N S T A L L A L L R E Q U I R E D P O W ER F E E D S , C O R N E R S , CO N N E C T I O N S E T C . F O R A C O M P L E T E T R A C K S Y S T E M . 11 . C O N N E C T A L L E X I T S I G N S T O E X I S T I N G E M E R G E N C Y L I GH T I N G C I R C U I T . 12 . C A R E F U L L Y R E M O V E , C L E A N , A N D R E I N S T A L L A S S H O W N I N N E W D E S I G N . LI G H T F I X T U R E S C H E D U L E N O T E S : • L I G H T I N G F I X T U R E S I N D I C A T E D I N S C H E D U L E A R E B A S I S O F D E S I G N , A L T E R N A T E M A N U F A C T U R E R S S H A L L B E P R E - A P PR O V E D B Y A D D E N D U M . AL T E R N A T E M A N U F A C T U R E R S S H A L L S U B M I T P E R - A P P R O V A L S TO E N G I N E E R A M I N I M U M O F 1 0 D A Y S P R I O R T O P R O J E C T B ID D A T E . • T H E S U F F I X ' E ' D E N O T E S A F I X T U R E S U P P L I E D W I T H A N E M E R G E N C Y T R A N S F E R D E V I C E . P R O V I D E A N O R M A L P O W E R SE N S I N G C I R C U I T . CO N T R O L F I X T U R E W I T H S U R R O U N D I N G F I X T U R E S . C O N N E C T TO E X I S T I N G E M E R G E N C Y L I G H T I N G C I R C U I T I N A R E A . C O N NE C T S U C H T H A T FI X T U R E W I L L I L L U M I N A T E U P O N N O R M A L P O W E R F A I L U R E . GE N E R A L L I G H T I N G S C H E D U L E N O T E S : 1. P R O V I D E 0 - 1 0 V D I M M I N G C O N D U C T O R S ( G R E Y & V I O L E T ) B E T W E E N D E V I C E A N D L I G H T F I X T U R E ( S ) F O R D I M M I N G A S I N D I C A T E D O N D W G S . 2. R O U T E A S S O C I A T E D R O O M L T G C I R C U I T T H R O U G H R E L A Y FO R C O N T R O L , P R O V D E 0 - 1 0 V D I M M I N G A N D L O W V O L T A G E C ON N E C T I O N S A S IN D I C A T E D O N D R A W I N G S A N D D E T A I L S . 3. D E V I C E C O L O R S H A L L M A T C H W I R I N G D E V I C E S ; R E F E R T O S P E C I F I C A T I O N S . 4. M O U N T D E V I C E T O B O T T O M O F S T R U C T U R E . nL I G H T L I G H T I N G C O N T R O L S C H E D U L E N O T E S : nL I G H T L I G H T I N G C O N T R O L S C H E D U L E G E N E R A L N O T E S : • E . C . S H A L L B E R E S P O N S I B L E F O R P R O V I D I N G A L L L I G H T IN G C O N T R O L C O M M I S S I O N I N G / P R O G R A M M I N G O F A L L n L I G H T C O M P O N E N T S . T H E CO M M I S S I O N I N G / P R O G R A M M I N G S H A L L B E D O N E B Y A n L I G H T C E R T I F I E D T E C H N I C I A N . • E . C . S H A L L N O T I F Y O W N E R 1 - W E E K P R I O R T O C O M M I S S I O NI N G / P R O G R A M M I N G O F T H E S Y S T E M S O T H A T T H E O W N E R C A N P R O V I D E RE P R E S E N T A T I V E S D U R I N G T H E C O M M I S S I O N I N G / P R O G R A M M I N G P E R I O D . 1. P R O V I D E A D D I T I O N A L P O W E R P A C K S ; S E N S O R S W I T C H P P 20 A S N E E D F O R Q T Y O F O C C U P A N C Y S E N S O R S / S W I T C H E S . 2. D E V I C E C O L O R S H A L L M A T C H W I R I N G D E V I C E S ; R E F E R T O S P E C I F I C A T I O N S . 3. R E F E R T O M A N U F A C T U R E R D O C U M E N T A T I O N F O R Q T Y A N D SI Z E O F C O N D U C T O R S B E T W E E N L O W V O L T A G E S W I T C H , S E N S OR ( S ) A N D PO W E R / R E L A Y P A C K S . 4. P R O V I D E S E C O N D A R Y R E L A Y P A C K ; S E N S O R S W I T C H S P 2 0 A S N E E D E D T O P R O V I D E D U A L - L E V E L S W I T C H I N G O F F I X T U RE S . 5. P R O V I D E 0 - 1 0 V D I M M I N G C O N D U C T O R S ( G R A Y & V I O L E T ) B E T W E E N S W I T C H A N D L I G H T F I X T U R E S F O R D I M M I N G C O N T RO L . 6. P R O G R A M O N / O F F T I M E S O F R E L A Y ' S A S D I R E C T E D B Y O WN E R . P R O V I D E C O M M I S S I O N I N G A S I N D I C A T E D I N G E N E R A L N O T E S B E L O W . 7. C U S T O M W A L L S T A T I O N E N G R A V I N G S I S R E Q U I R E D F O R W AL L S T A T I O N ( S ) A N D S H A L L B E S P E C I F I E D / C O O R D I N A T E D W IT H O W N E R A F T E R PR O G R A M I N G O F S Y S T E M . CO N T R O L & O C C U P A N C Y S E N S O R S C H E D U L E N O T E S : • E . C . S H A L L B E R E S P O N S I B L E F O R T H E P R O G R A M M I N G / C O M MI S S I O N I N G O F T H E L I G H T I N G C O N T R O L S Y S T E M S T O F U N C T IO N A S I N D I C A T E D O N TH E D R A W I N G S A N D S H A L L I N C L U D E A L L R E Q U I R E D C O S T I N T H E B A S E B I D . F O R A R E A S W I T H D A Y L I G H T I N G C O N T R O L , TH E D A Y L I G H T I N G S E T - PO I N T S S H A L L B E C O O R D I N A T E D W I T H T H E O W N E R F O R E A C H A R E A P R I O R T O F I N A L P R O G R A M M I N G O F T H E D A Y L I G H T I N G S E N S O R ( S ) . A L L PR O G R A M M I N G / C O M M I S S I O N I N G S H A L L B E D O N E B Y A F A C T O RY C E R T I F I E D O R T R A I N E D P E R S O N . • L I G H T I N G I S S P A C E S W I T H W I R E L E S S C O N T R O L S S H A L L B E F I E L D T U N E D T O F O O T C A N D L E L E V E L S T H A T A R E S A T I S F A CT O R Y T O T H E O W N E R DU R I N G P R O G R A M M I N G A N D C O M M I S S I O N I N G O F T H E W I R E L E S S C O N T R O L S Y S T E M . GE N E R A L L I G H T I N G C O N T R O L N O T E S : SC A L E : 3 / 4 " = 1 ' - 0 " A CH A N G I N G R O O M V A N I T Y E L E V A T I O N J J FBFB FB J J F F F F F CR CR F F M R M R M RM A B C D E F G H J K 3 4 5 6 7 8 ME N ' S R M [6 6 ] WO M E N ' S RM [6 4 ] ME C H A N I C A L RO O M [6 9 ] VE S T I B U L E [O - A ] HA L L W A Y [O - C ] ST O R A G E [6 3 ] ST A I R W E L L [O - B ] PI P E CH A S E [O - Q ] EL E V A T O R [O - D ] ME C H R M [6 7 ] CU S T R M [6 8 ] CL A S S R O O M [5 0 ] DA R K RO O M [5 9 D ] CO M P U T E R LA B [5 9 ] PH O T O ST U D I O [5 1 ] VE S T I B U L E [5 9 C ] OF F I C E [5 7 ] EQ U I P / CH E C K O U T [5 9 A ] ST O R A G E [5 9 B ] OF F I C E [5 5 ] FI L M [5 9 E ] AC O U S T I C S ST U D I O [5 2 B ] ST O R A G E [5 1 A ] CH A N G I N G [5 1 B ] VE S T I B U L E [0 - H ] OP T I C S L A B [5 2 A ] PH Y S I C S LA B [5 2 ] ST O R A G E [5 2 C ] 6D -5 AC AC AC AC AC CD CD 6D -5 'S ' 'R ( S E C 2 ) ' 'R ' 6D -5 1 1 1 3D -4 2D -4 2D -4 3D -4 3D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 6D -5 AC AC AC AC AC AC AC 2 2 2D -4 2D -4 2D -4 AC AC 2D -4 I E F -1 (A / E E 2 . 0 ) (A / E E 2 . 0 ) R -27 R -25 R -25 R -25 R -24 R -24 R -22 R -22 R -28 R -28 R -28 R -29 R -29 R -26 R -26 R -26 R -29 R -40 R -40 R -40 R -40 R -40 R -42 R -43 R -43 R -45 , 4 7 R -39 , 4 1 R -38 R -38 R -48 R -44 , 4 6 R -30 R -30 R -30 R -31 R -31 R -33 , 3 5 R -32 R -32 R -32 R -37 R -37 R -37 R -34 , 3 6 S -17 S -17 S -17 S -15 S -14 S -14 S -16 S -16 S -23 S -23 S -18 S -18 S -19 S -21 S -21 S -21 S -20 R -18R-20 R -18 R -18 R -18 R -18 R -19 R -19 R -19 R -20 R -20 R -21R-21 R -20 R -23 R -23 R -16 R -14 R -14 R -14 R -15 R -15 R -15 R -17 R -17 R -17 S -20 S -20 S -19 S -22 S -22 S -22 S -22 S -24 S -24 S -24 S -20 R -22 R -15 R -24 R -24 R -22 R -22 R -21 R -23R-48 S -25 R -49 S -20 R -13 R -49 R -49 S -26 S -28 S -30 S -31 S -33 S -35 R -19 R -21 R -23 R -30 R -30 R -31 R -31 R -42 R -42 R -42 R -13 S -19 S -18 S -16 S -14 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 1D -4 3 3 3 3 3 4 4 4 R -57 R -57 R -55 R -55 5 EX I S T I N G P A N E L M 6 7 8 EX I S T I N G F A C P 7 7 9 10 10 11 11 11 Bottom of Cable Tray Power Source/J-box 5'-0 AFF ±Heavy Duty #12 AWG Power Cord (2) GFI NEMA RecptaclesKellems Strain Relief Daniel Woodhead 3085-10x-a-123-GFI WORK TABLE 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 EE2.0LEVEL 0 ELECTRICAL PLAN22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 RemodelA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 S L I M L I N E A V S Y S T E M C A B I N E T . P R O V I D E ( 2 ) D U P L E X OUTLETS IN CABINET, EXTRA-DEEP BOX WITH 1 1/2" COND UIT TO ABOVE ACCESSIBLE CEILING FOR DATA/AV CABLING.COORDINATE EXACT PLACEMENT OF BOXES WITH CABINET AND KENDEN JENSEN (CAMPUS AV) PRIOR TO ROUGH IN.PROVIDE A #10 GREEN INSULATED GROUND CONDUCTOR FROM CABINET TO NEAREST ELECTRICAL ROOM GROUND BAR. FIELD VERIFY FINAL LOCATION PRIOR TO ROUGH-IN.2 M O U N T B E H I N D T V , C O O R D I N A T E M O U N T I N G W / T V M O U N T I N G BRACKET PRIOR TO ROUGH IN. PROVIDE EXTRA DEEP BOX SUCH AS, HUBBELL HBL260, W/ SINGLE GANG MUD RING W/ 1 1/4" C., TO ABOVE ACCESSIBLE CEILING. COORDINATE W/KENDEN JENSEN (CAMPUS AV) PRIOR TO ROUGH IN.3 M A I N T A I N A N D / O R R E - E S T A B L I S H E X I S T I N G C I R C U I T I N G T O ELECTRICAL DEVICE.4 N E W J U M B O 1 0 F T . T E L E P O W E R P O L E S U C H A S W I R E M O L D N'800. PROVIDE ALL NECESSARY ACCESSORIES AND COMPONENTS FOR ACCOMMODATING FURNITURE CONNECTIONS FOR THE CABLING AND DEVICES SHOWN.FINISH PER ARCHITECT.5 A D D A L T . # 6 P R O V I D E A N D I N S T A L L A P R O S T U D I O R A I L SYSTEM: MANFROTTO #FF3033 WITH TWO TELESCOPIC POSTS AND ONE PANTOGRAPH EXTENSION ARM. INSTALL PER MANUFACTURER'S INSTRUCTION. EXACT LOCATION PER OWNER IN FIELD.6 P R O V I D E A N D I N S T A L L ( 3 ) N E W 2 2 5 A 3 P B R E A K E R S I N EXISTING MAIN PANEL. FOR NEW PANELS L, R, AND S.REPLACE (3) EXISTING SPARE BREAKERS.7 P R O V I D E A N D I N S T A L L A 2 1 / 2 " C . , 4 - # 4 / 0 C U + G N D F ROM EACH NEW BREAKER TO EACH OF PANELS L, R, AND S. ROUTE CONCEALED ABOVE LAY IN CEILINGS. DORE DRILL ALL WAL L AND FLOOR PENETRATIONS.8 I T I S V E R Y C O N G E S T E D A B O V E P A N E L M W I T H E X I S T I N G CONDUIT. E.C. SHALL VISIT SITE AND OBSERVER EXISTIN G CONDITIONS AND INCLUDE THESE CONDITIONS IN BASE BID .9 A D D A L T . # 3 E . C . S H A L L P R O V I D E A N D I N S T A L L A N E W R G-8U COAX CABLE FROM THIS SPACE TO ROOF. COIL 50FT OF CABLE ABOVE CEILING FOR OWNERS USE.10 C O O R D I N A T E E X A C T O U T L E T L O C A T I O N W I T H O W N E R P R I O R TO ROUGH IN. LOCATE ACCESSIBLE TO LIGHT RAIL.11 F I R E / S M O K E D A M P E R . E . C . S H A L L P R O V I D E A 1 2 0 V C I R C UIT TO RELAY MODULE. DAMPER TO CLOSE UPON DETECTION.KEY NOTES:# SC A L E : 1 / 8 " = 1 ' - 0 " 1 LE V E L 0 P O W E R P L A N O V E R A L L NO R T H 16 ' 8' 0" EL E C T R I C A L F L O O R B O X S C H E D U L E ID D E S C R I P T I O N M F G R . F L O O R B O X p / n C O V E R P L A T E p / n PO W E R DE V I C E S DA T A DE V I C E S N O T E S FB 2 - G A N G , M U L T I - S E R V I C E C O N C R E T E FL O O R B O X , W / S U R F A C E S T Y L E RE C T A N G U L A R C O V E R , 3 " M I N . P O U R HU B B E L L C F B 2 G 3 0 C R 2 4 G C C V R X X X ( 2 ) D U P L E X RE C P T . 1,2,3 1. P R O V I D E R E Q U I R E D S U B - P L A T E S F O R I N S T A L L A T I O N O F PO W E R , D A T A A N D A V D E V I C E S . 2. E . C . S H A L L F I E L D L O C A T E E X A C T P L A C E M E N T O F F L O O R BO X W I T H A R C H I T E C T / O W N E R P R I O R T O I N S T A L L A T I O N . 3. P R O V I D E C O N D U I T ( S I Z E A S I N D I C A T E D O N D R A W I N G S ) TO A C C E S S I B L E C E I L I N G S P A C E F O R R O U T I N G O F D A T A A N D /OR LO W V O L T A G E C A B L I N G . FL O O R B O X S C H E D U L E N O T E S : SCALE: NONE A CORD DROP DETAILA. PROVIDE ALL EQUIPMENT, MATERIALS AND LABOR NECESS ARY TO EXPAND THE EXISTING FCI FIRE ALARM SYSTEM. THE SYSTEM ADDI TION SHALL BE CONNECTED DIRECTLY TO THE EXISTING MAIN FIRE ALA RM PANEL. THE INSTALLATION SHALL BE AS RECOMMENDED BY THE MAN UFACTURER AND ACCEPTED BY THE LOCAL AHJ. WHEN THE SYSTEM IS C OMPLETE, A FACTORY REPRESENTATIVE SHALL TEST THE SYSTEM, MAKE ADJUSTMENTS AND PLACE THE SYSTEM IN OPERATING ORDER .B. W I T H I N 3 0 D A Y S A F T E R T H E C O N T R A C T A W A R D A N D P R I O R TO THE PURCHASE OF ANY EQUIPMENT, THE FIRE ALARM SYSTEM CO NTRACTOR SHALL SUBMIT FOR APPROVAL SIX (6) COPIES OF THE FOL LOWING:a. A L I S T O F M A T E R I A L S T H A T A R E T O B E U S E D O N T H E P R OJECT, INCLUDING M A N U F A C T U R E R , M O D E L N U M B E R A N D T E C H N I C A L INFORMATION.b. P R E L I M I N A R Y C I R C U I T D I A G R A M S S H O W I N G I N T E R C O N N E C T ION OF ALL MONITORING, NOTIFICATION AND ANNUNCIATION DEVIC ES, PANELS AND WIRING COUNTS. DIAGRAMS ARE TO BE 11"X17 ", DONE IN A GOOD WORKMAN LIKE MANNER.c. T E C H N I C A L M A N U A L S F O R A L L O F T H E E Q U I P M E N T T H A T I S TO BE USED ON THE PROJECT.d. S U B M I T S H O P D R A W I N G S A N D R E Q U I R E D C A L C U L A T I O N S T O THE LOCAL AHJ. e. O B T A I N A W R I T T E N L E T T E R O F A C C E P T A N C E O F T H E P R O P OSED SYSTEM AND INCLUDE WITH THE SHOP DRAWING SUBMITTAL TO THE ENGINEER.C. C O N T R A C T O R S H A L L P R O V I D E A N D I N S T A L L A L L R E Q U I R E D POWER SUPPLIES, ELECTRONICS AND CONNECTIONS TO MODIFY EXI STING SYSTEM TO ACCEPT NEW ADDITION. THE COMPLETE SYSTEM SHALL M AINTAIN A UL LISTING.D. E L E C T R I C A L C O N T R A C T O R S H A L L I N C L U D E A $ 2 , 0 0 0 . 0 0 C ASH ALLOWANCE IN THE BID FOR MISCELLANEOUS ADDITIONS AND/OR REQUIREM ENTS IMPOSED BY THE LOCAL AHJ. FIRE ALARM EXPANSION NOTES: ME C H A N I C A L - I N L I N E E X H A U S T F A N S C H E D U L E EQ U I P . I D V O L T S / P H . H P C I R C U I T F E E D E R N O T E S IE F - 1 1 2 0 V / 1 1 / 3 R - 5 0 3 / 4 " C . , 2 # 1 2 + 1 # 1 2 G 1. C I R C U I T A N D C O N T R O L E X H A U S T F A N W I T H R O O M L I G H T I NG C I R C U I T . 2. E . C . S H A L L P R O V I D E L O C A L D I S C O N N E C T R A T E D , T H E R M AL - O V E R L O A D S W I T C H F O R E Q U I P M E N T ; S W I T C H R A T I N G S H A LL N O T B E L E S S T H E N CI R C U I T B R E A K E R S U P P L Y I N G E Q U I P M E N T . 3. E . C . S H A L L P R O V I D E L O C A L D I S C O N N E C T S W I T C H F O R E QU I P M E N T ; S I Z E A N D T Y P E A S I N D I C A T E D I N S C H E D U L E . I F F U S E D D I S C O N N E C T I S SP E C I F I E D F O R E Q U I P M E N T , F U S E P E R E Q U I P M E N T N A M E P L A TE R A T I N G . 4. E Q U I P M E N T I S F A C T O R Y S U P P L Y E D W I T H D I S C O N N E C T A N D C O N V I E N E N C E O U T L E T ; E . C . S H A L L P R O V I D E A L L N E C E S S AR Y C O N N E C T I O N S . 5. I N D O O R U N I T I S P O W E R E D F R O M O U T D O O R U N I T ; C O O R D I NA T E E X A C T N U M B E R O F C O N D U C T O R S B E T W E E N U N I T S W I T H M. C . P R I O R T O RO U G H - I N . 6. P R O V I D E 1 / 2 " C O N D U I T A N D C O N D U C T O R S B E T W E E N F U R N AC E A N D C O R R E S P O N D I N G O U T D O O R C O N D E N S I N G U N I T . C O O R DI N A T E S I Z E A N D NU M B E R O F C O N D U C T O R S W I T H M . C . P R I O R T O R O U G H - I N . P RO V I D E C O N N E C T I O N B E T W E E N F U R N A C E A N D A S S O C I A T E D O U TS I D E A I R MO T O R I Z E D D A M P E R , C O O R D I N A T E W I T H M . C . 7. E . C . S H A L L P R O V I D E C O M B I N A T I O N S T A R T E R / D I S C O N N E C T S W I T C H F O R E Q U I P M E N T ; S I Z E A N D T Y P E A S I N D I C A T E D IN S C H E D U L E . P R O V I D E WI T H C O N T R O L X F M R ( 2 ) S E T S O F N O / N C C O N T A C T S , C O N T R OL S W I T H M . C . P R I O R T O R O U G H - I N . F U S E D I S C O N N E C T P E R E Q U I P M E N T NA M E P L A T E R A T I N G . ME C H A N I C A L S C H E D U L E N O T E S : C A B C D E F 4 5 6 7 ST A I R W E L L [1 - P ] PH Y S I C A L GE O L O G Y RO O M [1 5 8 ] SE I S M O G R A P H RO O M [1 5 4 ] RE S O U R C E RO O M [1 5 0 A ] LA B O R A T O R Y [1 4 1 ] OF F I C E [1 5 0 ] OF F I C E [1 4 8 ] OF F I C E [1 4 6 ] OF F I C E [1 4 4 ] WO M E N ' S RM [1 3 2 ] ME N ' S R M [1 3 4 ] LE C T U R E HA L L [1 4 5 ] PR E P / S T O R A G E RM [1 4 3 ] HA L L W A Y [I - N ] HA L L W A Y [I - L ] HA L L W A Y [I - G ] UN I S E X R M [1 3 6 ] OF F I C E [1 4 2 ] ST A I R W E L L [1 - H ] EL E V A T O R [1 - J ] AC AC AC 1 1 1 1 1 1 2 3 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 EE2.1LEVEL 1 ELECTRICAL PLAN22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 RemodelA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 DISCONNECT POWER TO EXISTING LAB TABLES. INTERCEPT CONDUIT AND CONDUCTORS AND EXTEND UP TO J-BOX ON BOTTOM OF NEW OWNER FURNISHED TABLES. E.C. SHALL REFER TO SIMILAR WORK DONE IN ROOM 149 AS A MODEL FOR WORK HERE. MAKE CONNECTIONS TO NEW TABLES.2 E . C . S H A L L P R O T E C T A N D M A I N T A I N A L L E X I S T I N G L I G H T ING AND ELECTRICAL SERVICES IN THIS ROOM EXCEPT AS NOTE D.3 A D D A L T . # 3 E . C . T O C O R D D R I L L A N Y W A L L O R C E I L I N G PENETRATIONS. E.C. TO PROVIDE AND INSTALL WIREMOLD V2400 WITH ALL APPROPRIATED FITTINGS IN ALL FINISHE D SPACES.KEY NOTES:# NO R T H 16 ' 8' 0" SC A L E : 1 / 8 " = 1 ' - 0 " 1 LE V E L 1 P O W E R P L A N O V E R A L L n D nD S nD 1 S nD 1 S nD 1 J JJ JJJ F F 1 C D E F 2 3 4 5 CL A S S R O O M [2 7 7 ] OF F I C E [2 5 9 ] OF F I C E [2 6 1 ] OF F I C E [2 6 3 ] OF F I C E [2 6 5 ] ME N ' S RO O M [2 2 6 ] WO M E N ' S RO O M [2 2 0 ] CL A S S R O O M [2 7 6 ] CU S T R M [2 6 7 ] BD F R M [2 8 0 ] CU S T R M [2 2 8 ] ST O R A G E RM [2 7 7 A ] HA L L W A Y [2 - S ] EL E V A T O R [2 - G ] ST A I R W E L L [2 - T ] BI O - C H E M I S T R Y LA B [2 7 2 ] F3 F3 F3 F2 (T Y P ) F2 (T Y P ) F2 F3 E F2 E F2 E F2 E F2 E F2 E 'L ' 'L ( S E C 2 ) ' L -70 A 1 B C D E F 2 3 4 5 6 7 8 CL A S S R O O M [2 7 0 ] CL A S S R O O M [2 6 8 ] ME N ' S R M [2 6 6 ] WO M E N ' S RM [2 6 4 ] OF F I C E [2 5 2 ] OF F I C E [2 5 3 ] OF F I C E [2 5 0 ] OF F I C E [2 4 8 ] OF F I C E [2 4 6 ] OF F I C E [2 4 4 ] OF F I C E [2 4 2 ] OF F I C E [2 4 0 ] OF F I C E [2 3 8 ] WO R K RO O M [2 4 3 ] OF F I C E [2 3 6 ] OF F I C E [2 3 4 ] OF F I C E [2 3 9 ] OF F I C E [2 3 7 ] OF F I C E [2 3 5 ] OF F I C E [2 3 3 ] OF F I C E [2 3 2 ] CL A S S R O O M [2 5 5 ] CL A S S R O O M [2 7 7 ] OF F I C E [2 5 9 ] OF F I C E [2 6 1 ] OF F I C E [2 6 3 ] OF F I C E [2 6 5 ] ME N ' S RO O M [2 2 6 ] WO M E N ' S RO O M [2 2 0 ] CL A S S R O O M [2 7 6 ] CU S T R M [2 6 7 ] BD F R M [2 8 0 ] CU S T R M [2 2 8 ] ST O R A G E [2 5 8 ] ST O R A G E RM [2 7 7 A ] HA L L W A Y [2 - S ] LO U N G E [2 - V ] HA L L W A Y [2 - J ] SE C R E T A R Y / R E C E P T I O N RM [2 3 0 ] HA L L W A Y [2 - K ] CL A S S R O O M [2 6 0 ] CL A S S R O O M [2 6 2 ] HA L L W A Y [2 - L ] CU S T S T O R [2 1 6 ] ST A I R W E L L [2 - H ] EL E V A T O R [2 - G ] ST A I R W E L L [2 - T ] BI O - C H E M I S T R Y LA B [2 7 2 ] AC AC ACAC 'L ' 'L ( S E C 2 ) ' 6D -5 1 2D -4 2D -4 2D -4 1D -4 2D -4 2D -4 2D -4 1D -4 2D -4 2D -4 2D -4 2D -4 2 2 2 222 2D -4 AC AC AC AC AC AC AC AC 3 3 2D -3 2D -3 2D -3 4 4 (A / E E 2 . 2 ) 5 5 5 5 6 L -68 L -49 L -49 L -48L-48 L -50 L -50 L -53 L -53 L -71 , 7 3 , 7 5 L -64 , 6 6 L -44 L -44 L -46 L -46 L -46 L -43L-43 L -43 L -69 L -67 L -45 L -45 L -44 L -44 L -47 L -47 L -47 L -47 L -45 L -45 7 7 L -50 L -50 L -51 L -51 L -57 L -59 L -56 L -61 L -58 L -60 L -52 L -55 L -54 WEATHER HEAD COIL 48" OF EXCESS CABLE ON MAST FOR USE BY OWNER SEAL ROOF PENETRACTIONS AS DIRECTED BY ROOFING CONTRACTOR 2" RIGID CONDUIT ANCHOR TO STRUCTURE RG -86 COAX CABLE TO PHYSICS LAB ROOM 522' - 0"ROOF 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 EE2.2LEVEL 2 ELECTRICAL PLAN22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 RemodelA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 S L I M L I N E A V S Y S T E M C A B I N E T . P R O V I D E ( 2 ) D U P L E X OUTLETS IN CABINET, EXTRA-DEEP BOX WITH 1 1/2" COND UIT TO ABOVE ACCESSIBLE CEILING FOR DATA/AV CABLING.COORDINATE EXACT PLACEMENT OF BOXES WITH CABINET AND KENDEN JENSEN (CAMPUS AV) PRIOR TO ROUGH IN.PROVIDE A #10 GREEN INSULATED GROUND CONDUCTOR FROM CABINET TO NEAREST ELECTRICAL ROOM GROUND BAR. FIELD VERIFY FINAL LOCATION PRIOR TO ROUGH-IN.2 L O C A T E D E V I C E S I N C E I L I N G B E H I N D T . V . A D J A C E N T T O MOUNTING POST. PROVIDE EXTRA DEEP BOX SUCH AS;HUBBELL HBL260, WITH SINGLE GANG MUD RING AND BRUSH STYLE PLATE, MOUNTED FLUSH WITH CEILING.3 M O U N T R E C E P T A C L E S U N D E R T H E C O U N T E R R E C E S S E D I N CASE WORK. COORDINATE EXACT LOCATION WITH CASEWORK SHOP DRAWINGS.4 A D D A L T . # 3 E . C . T O C O R D D R I L L A N Y W A L L O R C E I L I N G PENETRATIONS. E.C. TO PROVIDE AND INSTALL WIREMOLD V2400 WITH ALL APPROPRIATED FITTINGS IN ALL FINISHE D SPACES.5 S E R V I C E P A N E L S U C H A S L A B L I N K # C P 2 4 X 2 4 - C P - 6 S - 2 C W / SIX 120V, 20A SINGLE RECEPTACLES. PROVIDE ALL NECESSARY COMPONENTS, DEVICES, AND CONNECTIONS FOR A COMPLETE SYSTEM.6 P R O V I D E A N D I N S T A L L A 2 1 / 2 " C . , 4 - # 4 / 0 C U + G N D F ROM EACH NEW BREAKER TO EACH OF PANELS L, R, AND S. ROUTE CONCEALED ABOVE LAY IN CEILINGS. DORE DRILL ALL WAL L AND FLOOR PENETRATIONS.7 F U M E H O O D S - M A K E A L L R E Q U I R E D C O N N E C T I O N S T O F U M E HOOD AND FUME HOOD CONTROLS.KEY NOTES:# SC A L E : 1 / 8 " = 1 ' - 0 " 1 LE V E L 2 O V E R A L L L I G H T I N G P L A N SC A L E : 1 / 8 " = 1 ' - 0 " 2 LE V E L 2 O V E R A L L P L A N 16 ' 8' 0" NO R T H 16 ' 8' 0" NO R T H A. PROVIDE ALL EQUIPMENT, MATERIALS AND LABOR NECESS ARY TO EXPAND THE EXISTING FCI FIRE ALARM SYSTEM. THE SYSTEM ADDI TION SHALL BE CONNECTED DIRECTLY TO THE EXISTING MAIN FIRE ALA RM PANEL. THE INSTALLATION SHALL BE AS RECOMMENDED BY THE MAN UFACTURER AND ACCEPTED BY THE LOCAL AHJ. WHEN THE SYSTEM IS C OMPLETE, A FACTORY REPRESENTATIVE SHALL TEST THE SYSTEM, MAKE ADJUSTMENTS AND PLACE THE SYSTEM IN OPERATING ORDER .B. W I T H I N 3 0 D A Y S A F T E R T H E C O N T R A C T A W A R D A N D P R I O R TO THE PURCHASE OF ANY EQUIPMENT, THE FIRE ALARM SYSTEM CO NTRACTOR SHALL SUBMIT FOR APPROVAL SIX (6) COPIES OF THE FOL LOWING:a. A L I S T O F M A T E R I A L S T H A T A R E T O B E U S E D O N T H E P R OJECT, INCLUDING M A N U F A C T U R E R , M O D E L N U M B E R A N D T E C H N I C A L INFORMATION.b. P R E L I M I N A R Y C I R C U I T D I A G R A M S S H O W I N G I N T E R C O N N E C T ION OF ALL MONITORING, NOTIFICATION AND ANNUNCIATION DEVIC ES, PANELS AND WIRING COUNTS. DIAGRAMS ARE TO BE 11"X17 ", DONE IN A GOOD WORKMAN LIKE MANNER.c. T E C H N I C A L M A N U A L S F O R A L L O F T H E E Q U I P M E N T T H A T I S TO BE USED ON THE PROJECT.d. S U B M I T S H O P D R A W I N G S A N D R E Q U I R E D C A L C U L A T I O N S T O THE LOCAL AHJ. e. O B T A I N A W R I T T E N L E T T E R O F A C C E P T A N C E O F T H E P R O P OSED SYSTEM AND INCLUDE WITH THE SHOP DRAWING SUBMITTAL TO THE ENGINEER.C. C O N T R A C T O R S H A L L P R O V I D E A N D I N S T A L L A L L R E Q U I R E D POWER SUPPLIES, ELECTRONICS AND CONNECTIONS TO MODIFY EXI STING SYSTEM TO ACCEPT NEW ADDITION. THE COMPLETE SYSTEM SHALL M AINTAIN A UL LISTING.D. E L E C T R I C A L C O N T R A C T O R S H A L L I N C L U D E A $ 2 , 0 0 0 . 0 0 C ASH ALLOWANCE IN THE BID FOR MISCELLANEOUS ADDITIONS AND/OR REQUIREM ENTS IMPOSED BY THE LOCAL AHJ. FIRE ALARM EXPANSION NOTES:SCALE: NONE A ROOF CONDUIT DETAIL - H A M R A D I O A N T E N N A 8270 S T A T E O F I D A H O T O D D P A Y N EREGISTEREDRPOFESSIONALENGINEER1823 E. Center Pocatello, Idaho 83201 tel (208) 232 -4439 www.payneengineeringinc.comEngineering Inc.Consulting Engineers3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet:title:revisions :p r o j e c t # :d a t e :UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND I S NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC.project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 P.E. #:22127 04-28-2023 EE3.0PANELSCHEDULES22.0540 04/28/2023[ SET PROJECT INFORMATION ADDRESS TEXT FIELD AND SET LOCATION UNDER ENERGY SETTINGS IF APPLICABLE ]Romney 2023 Remodel S = S H U N T - T R I P B R E A K E R G = G F C I B R E A K E R R = R E D H A N D L E D , LOCK-OUT TYPE A = A R C - F A U L T B R E A K E R GP = G F E P D B R E A K E R L C P = C R K T T O B E R O U T E D T H R O U G H L T G CONTROL PANEL BR K N O T E S : TO T A L E S T I M A T E D D E M A N D A M P S : 44 A TO T A L A M P S : 160 A 1 8 0 A 1 6 7 A TO T A L L O A D : 19.2 kVA 2 1 . 5 k V A 1 9 . 9 k V A 83 S P A R E - - 2 0 A 1 0 0 1 2 0 A - - S P A R E 8 4 81 S P A R E - - 2 0 A 1 0 0 1 2 0 A - - S P A R E 8 2 79 S P A R E - - 2 0 A 1 0 0 1 2 0 A - - S P A R E 8 0 77 S P A R E - - 2 0 A 1 0 0 1 2 0 A - - S P A R E 7 8 75 167 0 1 2 0 A - - S P A R E 7 6 73 16 7 0 1 2 0 A - - S P A R E 7 4 71 La b E q u i p m e n t 2 0 A 3 167 0 1 2 0 A - - S P A R E 7 2 69 F u m e H o o d 2 0 A 1 5 0 0 1 2 8 0 1 2 0 A L i g h t i n g 7 0 67 F u m e H o o d 2 0 A 1 5 0 0 3 6 0 1 2 0 A R e c e p t a c l e 6 8 65 R e c e p t a c l e 2 0 A 1 3 6 0 2 5 0 0 66 63 R e c e p t a c l e 2 0 A 1 3 6 0 2 5 0 0 2 2 0 A L a b E q u i p m e n t 64 61 R e c e p t a c l e 2 0 A 1 3 6 0 3 6 0 1 2 0 A R e c e p t a c l e 6 2 59 R e c e p t a c l e 2 0 A 1 3 6 0 3 6 0 1 2 0 A R e c e p t a c l e 6 0 57 R e c e p t a c l e 2 0 A 1 3 6 0 3 6 0 1 2 0 A R e c e p t a c l e 5 8 55 R e c e p t a c l e 2 0 A 1 3 6 0 3 6 0 1 2 0 A R e c e p t a c l e 5 6 53 R e c e p t a c l e 2 0 A 1 3 6 0 3 6 0 1 2 0 A R e c e p t a c l e 5 4 51 R e c e p t a c l e 2 0 A 1 3 6 0 3 6 0 1 2 0 A R e c e p t a c l e 5 2 49 R e c e p t a c l e 2 0 A 1 7 2 0 7 2 0 1 2 0 A R e c e p t a c l e 5 0 47 R e c e p t a c l e 2 0 A 1 7 2 0 7 2 0 1 2 0 A R e c e p t a c l e 4 8 45 R e c e p t a c l e 2 0 A 1 7 2 0 5 4 0 1 2 0 A R e c e p t a c l e 4 6 43 R e c e p t a c l e 2 0 A 1 5 4 0 7 2 0 1 2 0 A R e c e p t a c l e 4 4 41 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 4 2 39 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 4 0 37 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 3 8 35 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 3 6 33 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 3 4 31 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 3 2 29 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 3 0 27 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 2 8 25 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 2 6 23 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 2 4 21 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 2 2 19 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 2 0 17 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 1 8 15 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 1 6 13 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 1 4 11 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rcuit 1 2 9 1000 1 0 0 0 1 2 0 A - - E x i s t i n g C i r c u i t 1 0 7 10 0 0 1 0 0 0 8 5 Ex i s t i n g C i r c u i t - - 3 0 A 3 1000 1 0 0 0 2 3 0 A - - E x i s t i n g C i r c u i t 6 3 1000 1 0 0 0 4 1 Ex i s t i n g C i r c u i t - - 2 0 A 2 10 0 0 1 0 0 0 2 2 0 A - - E x i s t i n g C i r c u i t 2 CK T C I R C U I T D E S C R I P T I O N N O T E A M P S P A B C P A M P S N O T E C I R C U I T DESCRIPTION C K T NO T E S : MF G & M O D E L : SQ . D / N Q S E R I E S DI M E N S I O N S : 20"W x 5.8"D x *"H FEED: EN C L O S U R E : B U S S I N G : SEE SPEC'S MBR AMPS:N/A MO U N T I N G : Re c e s s e d WI R E S : 4 PANEL AMPS:225 A FE D F R O M : P H A S E S : 3 PANEL TYPE:MLO R o m n e y 2 0 2 3 R e m o d e l LO C A T I O N : V O L T A G E : 120/208 Wye A.I.C. RATING:10K PROJECT: PA N E L : L PAYNE ENGINEERING S = S H U N T - T R I P B R E A K E R G = G F C I B R E A K E R R = R E D H A N D L E D , L O C K - O U T T Y P E A = A R C - F A U L T B R E A K E R GP = G F E P D B R E A K E R L C P = C R K T T O B E R O U T E D T H R O U G H L T G C O N T R O L P A N E L BR K N O T E S : TO T A L E S T I M A T E D D E M A N D A M P S : 10 3 A TO T A L A M P S : 12 8 A 2 1 0 A 2 0 1 A TO T A L L O A D : 15 . 4 k V A 2 4 . 0 k V A 2 3 . 0 k V A 83 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 8 4 81 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 8 2 79 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 8 0 77 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 7 8 75 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 7 6 73 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 7 4 71 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 7 2 69 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 7 0 67 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 6 8 65 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 6 6 63 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 6 4 61 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 6 2 59 S P A R E - - 2 0 A 1 0 - - 1 - - - - P R E P A R E D S P A C E 6 0 57 R e c e p t a c l e 2 0 A 1 3 6 0 - - 1 - - - - P R E P A R E D S P A C E 5 8 55 R e c e p t a c l e 2 0 A 1 3 6 0 - - 1 - - - - P R E P A R E D S P A C E 5 6 53 L i g h t i n g 20 A 1 1 5 5 6 2 0 0 0 1 2 0 A T r a c k L i g h t i n g 5 4 51 L i g h t i n g 20 A 1 1 4 3 7 1 2 5 0 1 2 0 A T r a c k L i g h t i n g 5 2 49 R e c e p t a c l e 2 0 A 1 5 4 0 8 6 4 1 2 0 A I E F - 1 5 0 47 25 0 0 3 6 0 1 2 0 A R e c e p t a c l e 4 8 45 El e c t r i c C l o t h e s D r y e r 2 0 A 2 25 0 0 2 5 0 0 46 43 R e c e p t a c l e 2 0 A 1 7 2 0 2 5 0 0 2 2 0 A R e c e p t a c l e 44 41 25 0 0 7 2 0 1 2 0 A R e c e p t a c l e 4 2 39 Re c e p t a c l e 2 0 A 2 25 0 0 9 0 0 1 2 0 A R e c e p t a c l e 4 0 37 R e c e p t a c l e 2 0 A 1 5 4 0 3 6 0 1 2 0 A R e c e p t a c l e 3 8 35 25 0 0 2 5 0 0 36 33 Re c e p t a c l e 2 0 A 2 25 0 0 2 5 0 0 2 2 0 A R e c e p t a c l e 34 31 R e c e p t a c l e 2 0 A 1 1 3 6 0 5 4 0 1 2 0 A R e c e p t a c l e 3 2 29 R e c e p t a c l e 2 0 A 1 5 4 0 9 0 0 1 2 0 A R e c e p t a c l e 3 0 27 R e c e p t a c l e 2 0 A 1 3 6 0 5 4 0 1 2 0 A R e c e p t a c l e 2 8 25 R e c e p t a c l e 2 0 A 1 5 4 0 5 4 0 1 2 0 A R e c e p t a c l e 2 6 23 R e c e p t a c l e 2 0 A 1 7 2 0 7 2 0 1 2 0 A R e c e p t a c l e 2 4 21 R e c e p t a c l e 2 0 A 1 7 2 0 9 0 0 1 2 0 A R e c e p t a c l e 2 2 19 R e c e p t a c l e 2 0 A 1 9 0 0 7 2 0 1 2 0 A R e c e p t a c l e 2 0 17 R e c e p t a c l e 2 0 A 1 5 4 0 9 0 0 1 2 0 A R e c e p t a c l e 1 8 15 R e c e p t a c l e 2 0 A 1 7 2 0 3 6 0 1 2 0 A R e c e p t a c l e 1 6 13 R e c e p t a c l e 2 0 A 1 3 6 0 5 4 0 1 2 0 A R e c e p t a c l e 1 4 11 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rc u i t 1 2 9 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i r cu i t 1 0 7 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i r cu i t 8 5 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i r cu i t 6 3 10 0 0 1 0 0 0 4 1 Ex i s t i n g C i r c u i t - - 3 0 A 2 10 0 0 1 0 0 0 2 3 0 A - - E x i s t i n g C i r c u i t 2 CK T C I R C U I T D E S C R I P T I O N N O T E A M P S P A B C P A M P S N O T E C I R C U I T D E S C R I P T I O N C K T NO T E S : MF G & M O D E L : SQ . D / N Q S E R I E S DI M E N S I O N S : 20 " W x 5 . 8 " D x * " H FE E D : EN C L O S U R E : B U S S I N G : SE E S P E C ' S MB R A M P S : N/ A MO U N T I N G : Re c e s s e d WI R E S : 4 PA N E L A M P S : 22 5 A FE D F R O M : P H A S E S : 3 PA N E L T Y P E : ML O R o m n e y 2 0 2 3 R e m o d e l LO C A T I O N : V O L T A G E : 12 0 / 2 0 8 W y e A. I . C . R A T I N G : 10 K PR O J E C T : PA N E L : R PA Y N E E N G I N E E R I N G S = S H U N T - T R I P B R E A K E R G = G F C I B R E A K E R R = R E D H A N D L E D , L O C K - O U T T Y P E A = A R C - F A U L T B R E A K E R GP = G F E P D B R E A K E R L C P = C R K T T O B E R O U T E D T H R O U G H L T G C O N T R O L P A N E L BR K N O T E S : TO T A L E S T I M A T E D D E M A N D A M P S : 39 A TO T A L A M P S : 84 A 7 5 A 7 1 A TO T A L L O A D : 10 . 0 k V A 8 . 9 k V A 8 . 5 k V A 41 S P A R E - - 2 0 A 1 0 0 1 2 0 A - - S P A R E 4 2 39 S P A R E - - 2 0 A 1 0 0 1 2 0 A - - S P A R E 4 0 37 S P A R E - - 2 0 A 1 0 0 1 2 0 A - - S P A R E 3 8 35 R e c e p t a c l e 2 0 A 1 5 4 0 0 1 2 0 A - - S P A R E 3 6 33 R e c e p t a c l e 2 0 A 1 7 2 0 0 1 2 0 A - - S P A R E 3 4 31 R e c e p t a c l e 2 0 A 1 5 4 0 1 2 6 0 1 2 0 A L i g h t i n g 3 2 29 L i g h t i n g 20 A 1 8 6 0 7 2 0 1 2 0 A R e c e p t a c l e 3 0 27 L i g h t i n g 20 A 1 1 5 1 0 5 4 0 1 2 0 A R e c e p t a c l e 2 8 25 R e c e p t a c l e 2 0 A 1 1 8 0 7 2 0 1 2 0 A R e c e p t a c l e 2 6 23 R e c e p t a c l e 2 0 A 1 7 2 0 5 4 0 1 2 0 A R e c e p t a c l e 2 4 21 R e c e p t a c l e 2 0 A 1 5 4 0 7 2 0 1 2 0 A R e c e p t a c l e 2 2 19 R e c e p t a c l e 2 0 A 1 9 0 0 9 0 0 1 2 0 A R e c e p t a c l e 2 0 17 R e c e p t a c l e 2 0 A 1 5 4 0 5 4 0 1 2 0 A R e c e p t a c l e 1 8 15 R e c e p t a c l e 2 0 A 1 3 6 0 5 4 0 1 2 0 A R e c e p t a c l e 1 6 13 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 5 4 0 1 2 0 A R e c e p t a c l e 1 4 11 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i rc u i t 1 2 9 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i r cu i t 1 0 7 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i r cu i t 8 5 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i r cu i t 6 3 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i r cu i t 4 1 E x i s t i n g C i r c u i t - - 2 0 A 1 1 0 0 0 1 0 0 0 1 2 0 A - - E x i s t i n g C i r cu i t 2 CK T C I R C U I T D E S C R I P T I O N N O T E A M P S P A B C P A M P S N O T E C I R C U I T D E S C R I P T I O N C K T NO T E S : MF G & M O D E L : SQ . D / N Q S E R I E S DI M E N S I O N S : 20 " W x 5 . 8 " D x * " H FE E D : EN C L O S U R E : B U S S I N G : SE E S P E C ' S MB R A M P S : N/ A MO U N T I N G : Re c e s s e d WI R E S : 4 PA N E L A M P S : 22 5 A FE D F R O M : P H A S E S : 3 PA N E L T Y P E : ML O R o m n e y 2 0 2 3 R e m o d e l LO C A T I O N : V O L T A G E : 12 0 / 2 0 8 W y e A. I . C . R A T I N G : 10 K PR O J E C T : PA N E L : S PA Y N E E N G I N E E R I N G