HomeMy WebLinkAboutTGI REPAIRS - 22-00151 - 1011 Pine Brook Ln - New SFR TECHNICAL BULLETIN TB-319 March 2023 (Expires 3/2025) Page 1 of 2 1.888.453.8358 ● www.weyerhaeuser.com/woodproducts/ Weyerhaeuser Engineered Wood Products Header-Off Span Table For certain situations, a typical repair detail may not be sufficient or there may not be enough room to install the required repair materials. In such cases, the most common method of repairing the damaged joist is to install a header on either side of the damaged region and attach the header(s) to the adjacent, undamaged joists. This repair technique is typically referred to as Header-Off, Headered-Off, or Head-Out. Table 1 and Table 2 below give the maximum allowable clear spans for both the damaged jois t and the adjacent, undamaged joists. Detail H2A on page 3 and Detail L3A on page 4 provide supplementary information regarding the installation of a Header-Off repair. TABLE 1: TJI® JOIST HEADER-OFF[1][2] [1] See General Notes on page 2. [2] See Detail H2A on page 3. TABLE 2: 1.5E TIMBERSTRAND® LSL JOIST HEADER-OFF[1][2] [1] See General Notes on page 2. [2] See Detail L3A on page 4. Joist Depth TJI® Series Maximum Allowable Clear Span 40 PSF Live Load / 10 PSF Dead Load 40 PSF Live Load / 20 PSF Dead Load 12″ o.c. 16″ o.c. 19.2″ o.c. 24″ o.c. 12″ o.c. 16″ o.c. 19.2″ o.c. 24″ o.c. 9½″ 110 14′-8″ 13′-4″ 12′-7″ 10′-2″ 14′-8″ 12′-9″ 10′-7″ 8′-5″ 210 15′-4″ 14′-0″ 13′-2″ 11′-4″ 15′-4″ 14′-0″ 11′-9″ 9′-5″ 230 15′-10″ 14′-5″ 13′-7″ 12′-7″ 15′-10″ 14′-5″ 13′-3″ 10′-7″ 11⅞″ 110 17′-5″ 15′-4″ 12′-9″ 10′-2″ 16′-7″ 12′-9″ 10′-7″ 8′-5″ 210 18′-3″ 16′-8″ 14′-2″ 11′-4″ 18′-3″ 14′-2″ 11′-9″ 9′-5″ 230 18′-9″ 17′-1″ 15′-11″ 12′-8″ 18′-9″ 15′-11″ 13′-3″ 10′-7″ 360 19′-10″ 18′-0″ 16′-3″ 13′-0″ 19′-10″ 16′-3″ 13′-6″ 10′-9″ 560 22′-6″ 20′-6″ 19′-3″ 15′-10″ 22′-6″ 19′-10″ 16′-6″ 13′-2″ 14″ 110 19′-9″ 15′-4″ 12′-9″ 10′-2″ 17′-1″ 12′-9″ 10′-7″ 8′-5″ 210 20′-9″ 17′-0″ 14′-2″ 11′-4″ 18′-11″ 14′-2″ 11′-9″ 9′-5″ 230 21′-4″ 19′-2″ 15′-11″ 12′-8″ 20′-11″ 15′-11″ 13′-3″ 10′-7″ 360 22′-6″ 19′-6″ 16′-3″ 13′-0″ 21′-9″ 16′-3″ 13′-6″ 10′-9″ 560 25′-7″ 23′-2″ 19′-10″ 15′-10″ 25′-7″ 19′-10″ 16′-6″ 13′-2″ 16″ 210 22′-9″ 17′-0″ 14′-2″ 11′-4″ 18′-11″ 14′-2″ 11′-9″ 9′-5″ 230 23′-7″ 19′-2″ 15′-11″ 12′-8″ 21′-3″ 15′-11″ 13′-3″ 10′-7″ 360 24′-11″ 19′-6″ 16′-3″ 13′-0″ 21′-9″ 16′-3″ 13′-6″ 10′-9″ 560 28′-3″ 23′-10″ 19′-10″ 15′-10″ 26′-6″ 19′-10″ 16′-6″ 13′-2″ Joist Size Joist Weight (plf) Maximum Allowable Clear Span 40 PSF Live Load / 15 PSF Dead Load 40 PSF Live Load / 25 PSF Dead Load 12″ o.c. 16″ o.c. 19.2″ o.c. 24″ o.c. 12″ o.c. 16″ o.c. 19.2″ o.c. 24″ o.c. 1½″ x 9½″ 4.5 15′-2″ 14′-0″ 13′-3″ 12′-5″ 15′-2″ 14′-0″ 13′-3″ 11′-4″ 1½″ x 11⅞″ 5.6 18′-9″ 17′-3″ 16′-4″ 13′-5″ 18′-9″ 17′-0″ 14′-2″ 11′-4″ 1½″ x 14″ 6.6 21′-11″ 20′-1″ 16′-9″ 13′-5″ 21′-8″ 17′-0″ 14′-2″ 11′-4″ Span values have not been evaluated for the effects of differential deflection and possible impacts on floor finishes. For a more detailed analysis, contact your Weyerhaeuser representative. , Weyerhaeuser, ForteWEB, Javelin, Microllam, Parallam, TimberStrand, TJ, TJI, and Trus Joist are registered trademarks and Edge, Edge Gold, and TJ-Pro are trademarks of Weyerhaeuser NR. © 2023 Weyerhaeuser NR Company. All rights reserved. TECHNICAL BULLETIN TB-319 March 2023 (Expires 3/2025) Page 2 of 2 1.888.453.8358 ● www.weyerhaeuser.com/woodproducts/ General Notes • Tables are based on: - Uniform loads. - Live load deflection criteria L/480. - More restrictive of simple or continuous span. - Clear distance between supports. - Minimum bearing length of 1¾″ end (no web stiffeners for TJI® joists) and 3½″ intermediate. • Glue-nailed floor sheathing assumed. • For continuous spans, ratio of short span to long span should be 0.4 or greater to prevent uplift. • Tables show maximum allowable clear span of damaged joist and adjacent joists for Header-Off repair. - Assumes worst case of moment, shear, reaction, and deflection controls. • Verify existing holes in TimberStrand® LSL or TJI® joists are still acceptable prior to installing header. • 12″ maximum spacing between headers. • Install additional framing in opening to support sheathing as required. If you have any questions, please contact your Weyerhaeuser representative. For TJI® josts, see TJ-4000 for additional information and installation details. For TimberStrand® LSL joists, see TJ-8014.