Loading...
HomeMy WebLinkAboutSIGN SPECS - 23-00220 - Maverik - 859 W Main St - SignVersion Address COLOR MATCHING NOTE Colors specied in this package are to match vendor supplied physical samples. Colors chosen based upon how they appear on a computer monitor or printed media are not guaranteed to match. PRODUCTION NOTE The PDF format of this package may contain graphics which have been down-sampled for proong purposes and should not be used for production purposes. Source les for this package are available upon request for production purposes. TYPOGRAPHY NOTE All vertical typography dimensions specied in this package are based upon the measurement from the baseline to the cap-line of an uppercase letter ‘i’. The height of descenders and ascenders, below and above the baseline and cap-line respectively, are not included in the measurements unless specically noted. x-HeightOver-All Height (O.A.H.) Cap-line Baseline Maverik #505 859 W Main St Rexburg ID 83440 Store Sign Refurbish Package by Salt Lake Region Salt Lake Ofce 1605 South Gramercy Road Salt Lake City, UT 84104 801-487-8481 OPY-53673-R0 Date: 04.05.2023 Dimensioned LetterHeight ART Acct. Exec: Designer: Approval Client Sign / Date A/E Sign / Date 1605 South Gramercy Rd. Salt Lake City, UT 84104 801.487.8481 www.yesco.com © 2022 YESCO LLC. All right reserved This drawing was created to assist you in visualizing our proposal. The original ideas herein are the property of YESCO LLC. Permission to copy or revise this drawing can only be obtained through a written agreement with YESCO. The colors shown are only approximated on any computer monitor, inkjet or laser print. The nal product may vary slightly in color from your computer monitor or print. This sign is installed in accordance with the requirements of Article 600 of the National Electrical Code and / or other applicable local codes. This includes proper grounding and bonding of the sign. DESIGN Revisions No.Date / Description Org. JO # 1 --- --- --- --- --- --- --- --- 02.17.2023 1.0 Rexburg ID 83440 859 W Main St Maverik #505 R0 Mitchell E Stapley Matthew R Wren OPY- 53673 04.05.2023 Permit updates (GB) BUILDING ELEVATION AREA= 2438 SF SIGN AREA= 49.9 SF SIGN AREA IS 2.04 % OF BUILDING ELEVATION AREA TO PARAPET GROUND LEVEL Electrical Requirements: 3 Amps -120 V Electrical disconnectswitch. MAVERIK CONTRACTER TO REMOVE AND DISPOSE OF EXISTING SIGN. MANUFAC- TURE AND INSTALL ONE [1] PAN CHANNEL, INTERNALLY ILLUMINATED DISPLAY. SCOPE OF WORK FINAL ELECTRICAL CONNECTION: USE EXISTING PRIMARY POWER TO SIGN LOCATION PERMITTING SIGN AREA:49.9 FT² COLOR KEY Note: Unless otherwise noted, the colors depicted on this rendering may not match actual colors on nished display. Please refer to color-callouts and their appropriate vendor specied samples for approved color specications. P2 Pre-painted Duranodic P1 SW 7020 Black Fox Trim caps #313 Bronze Acrylic 3RK32/2283 C1 C2 NIGHT VIEW 1 SIGN 01 - PAN CHANNEL DISPLAY SCALE: 3/8" = 1'-0" C2 P2 C1 Aluminum pan channel letters/logo. Returns: 5” Duranonic Trimcaps: 1” Bronze Faces: Acrylic (see color key) Illumination: Red LED’s Mounted to building fascia 2 SIGN 01 - SIDE VIEW SCALE: 3/8" = 1'-0" BUILDING NORTH ELEVATION SURVEY REQUESTED SURVEY REQUIRED TO VERIFY BUILDING SIGN AREA 3' - 7 5 /8 " 1' - 1 1 5 /8 " 4' - 5 5 /8 " 11'-2" 5" 106' 23 ' ART Acct. Exec: Designer: Approval Client Sign / Date A/E Sign / Date 1605 South Gramercy Rd. Salt Lake City, UT 84104 801.487.8481 www.yesco.com © 2022 YESCO LLC. All right reserved This drawing was created to assist you in visualizing our proposal. The original ideas herein are the property of YESCO LLC. Permission to copy or revise this drawing can only be obtained through a written agreement with YESCO. The colors shown are only approximated on any computer monitor, inkjet or laser print. The nal product may vary slightly in color from your computer monitor or print. This sign is installed in accordance with the requirements of Article 600 of the National Electrical Code and / or other applicable local codes. This includes proper grounding and bonding of the sign. DESIGN Revisions No.Date / Description Org. JO # 1 --- --- --- --- --- --- --- --- 02.17.2023 2.0 Rexburg ID 83440 859 W Main St Maverik #505 R0 Mitchell E Stapley Matthew R Wren OPY-53673 04.05.2023 Permit updates (GB) BUILDING ELEVATION AREA= 1113 SF SIGN AREA= 14.3 SF SIGN AREA IS 1.28 % OF BUILDING ELEVATION AREA BUILDING EAST ELEVATION TO PARAPET GROUND LEVEL 21 ' 53' 6'-0" 2' - 4 3 /4 " 1' - 1 1 3 /8 " 1' - 0 5 /8 " 3"5" 1 SIGN 02 - PAN CHANNEL DISPLAY SCALE: 3/4" = 1'-0"2 SIGN 02 - SIDE VIEW SCALE: 3/4" = 1'-0" Electrical Requirements: 2 Amps -120 V Aluminum pan channel letters/logo. Returns: 5” Duranonic Trimcaps: 1” Bronze Faces: Acrylic (see color key) Illumination: Red LED’s Mounted to building fascia on raceways. Electrical disconnectswitch. P2 P3 C1 3”x 5” aluminum raceways. Paint nish: SW 7043 Worldly Gray. MANUFACTURE AND INSTALL ONE [1] PAN CHANNEL, INTERNALLY ILLUMINATED, RACEWAY MOUNTED DISPLAY. SCOPE OF WORK FINAL ELECTRICAL CONNECTION: USE EXISTING PRIMARY POWER TO SIGN LOCATION PERMITTING SIGN AREA:14.3 FT² COLOR KEY Note: Unless otherwise noted, the colors depicted on this rendering may not match actual colors on nished display. Please refer to color-callouts and their appropriate vendor specied samples for approved color specications. P2 Pre-painted Duranodic P3 SW 7043 Worldly Gray Trim caps #313 Bronze Acrylic 3RK32/2283 C1 C2 NIGHT VIEW DETAIL NTS 16 ' - 1 1 "