Loading...
HomeMy WebLinkAboutMETHOD SPECIFICATIONS - 23-00046 - 240 E Moody - Wendy's - New BuildingInspection Details Date Contractor Inspector Weather Ambient Temperature (°F) Permit Number 05/01/2023 Construction Solutions Neibaur, Ricardo Sunny 81 23­00046 Compaction Equipment Model:Weight/Vibration Number of Tires Speed (mph) N/A N/A 2 1 Method Specification Inspection Test #Location or Station Elevation Material Placed Lift Thickness(in) # of Full Passes Density (pcf) (if applicable) In Compliance 1 Southeast side of jobsite within concrete foundation 8 Inches below top of foundation Pit run 12 12 N/A Yes Material Tested per: ISPWC 202­3.8­C­3 Atlas Geotechnical Report Other Source (Material located in Notes Section) Notes: The specifications were not provided nor found by Atlas Rep. (Rick) Since the roller appeared the roller looked to meet ISPWC requirements, therefore contractor (Josh) elected to move forward following thr bare minimum requirements per ISPWC. Email has been sent to all approved recipients. ✔ Method Specification ­00Report #: 05/01/2023Report Date: Atlas Technical Consultants, LLC ­ Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529­8242 Client: Classic Foods, Inc. 1585 N. Skyline Drive Idaho Falls, ID 83402 Project: E230566l Wendy's ­ Rexburg, Moody Rd & N. 2nd E., Rexburg, ID 240 E Moody Road Rexburg, ID 83440 This report shall not be reproduced, in full, without prior written approval of Atlas Technical Consultants, LLC. Results only relate to the items inspected or tested. Page 1 of 2Page 1 of 1