Loading...
HomeMy WebLinkAboutCONCRETE REPORT 3 - 23-00046 - 240 E Moody - Wendy's - New BuildingSpecimen Number Test Age Days Test Date Field / Lab Cure Days Average Cylinder Diameter (in) Cylinder Area (in²) Max Load (lbs) Strength (psi) Fracture Type Break Remark Capping Method 3-1 7 05/05/23 / 3-2 28 05/26/23 / 3-3 28 05/26/23 / 3-4 28 05/26/23 / 3-5 28 H 05/26/23 / Set #:3 Specimen Size:4" X 8" Specimens In Set:5 Truck / Ticket #:5767008 / 79115966 Contractor:Classic Foods Inc Technician:Sellers, Bradley Cast By:Sellers, Bradley Date Cast:04/28/23 Sampled From:Chute Placement Method:Chute Sample Details Batched:10:33 MDT Sampled:11:35 MDT Cast:11:48 MDT Truck Empty:12:00 MDT Placement Time:87 (min) Placement Location:Interior - Slab on Grade Location Details:North building pad Freezer 110, Cooler 111, receiving 112 and north east corner footing for trash can bins. Sample Location / Notes:¶east ¶north from southwest side of receiving room 112 Batch Log Strength:3500 (psi) Slump:6 - 8 (in) Specifications Supplier:Idaho Materials and Construction (IMC) Plant:83 Mix Design:3325605 On-Site Admixtures: None Location Field Measurements Plastic Unit Weight:15.1 (lb/ft³) (ASTM C138) Air Content:2.0 (ASTM C231) Load Volume:6.75 (yd³) Weather:Sunny Slump (in):6-3/4 (ASTM C143) Air Temperature (F):42 Concrete Temp (F):65 (ASTM C1064) Lab Test Results General Remarks 3-5: Cylinders are located on east side of site by porta potty This report shall not be reproduced, in full, without prior written approval of Atlas Technical Consultants, LLC. Results only relate to the items inspected or tested. Page 1 of 1 Client: Classic Foods, Inc. Idaho Falls, ID 83402 1585 N. Skyline Drive Project: Wendy's - Rexburg, Moody Rd & N. 2nd E., Rexburg, ID E230566l Rexburg, ID 83440 240 E Moody Road 43.854507, -111.776561 Compressive Strength of Concrete Test Method: ASTM C 39 Sample: 11534 Report #: -00 Atlas Technical Consultants, LLC - Idaho Falls 1753 E Precision Drive Idaho Falls, ID 83402 Phone: (208) 529-8242 Report Date: 04/28/2023