Loading...
HomeMy WebLinkAboutREDLINED COMBINED PLANS - 21-00488 - Denny's - New Commercial BldgAuthor Name Author Email Author Phone No.: Bret Stoddard brets@rexburg.org 208-372-2171 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Joel Gray Joel.Gray@rexburg.org 208-372-2331 Don Allen Don.Allen@rexburg.org 208-372-2174 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : Denny's - New Commercial Bldg Address : 585 N 2nd E Application Type : Document Filename : full Dennys Rexburg set.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 100 T1.0 title sheet Free text Cody Jones : Building Open 1 with sprinkler system 100 T1.0 title sheet Free text Cody Jones : Building Open 1 Building will be located in flood zone, will need flood certificate. 101 T1.1 occupancy plan Free text Cody Jones : Building Open 2 Seating at tables, counters, and work areas comply with IBC section 1109.11 300 A1.0 floor plan Free text Cody Jones : Building Open 9 Glass and glazing will need to meet requirements of Chapter 24. 304 A2.1 ceiling details Free text Cody Jones : Building Open 13 Ceiling to be built to manufacturers specifications. 305 A3.0 roof plan Free text Cody Jones : Building Open 14 Roof and roof fire classification? # 21-00488 New Commercial Building Report Date: 08.11.2021 Approval of plans does not constitute approval of variance from code Page 1 of 3 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 309 A5.0 building sections Free text Cody Jones : Building Open 18 All other concealed areas need to be fireblocked/draftsopped if any. 314 A8.0 door schedule Free text Cody Jones : Building Open 23 Panic hardware to be installed on Egress doors, or required signage. 502 S1.2 structural details Free text Cody Jones : Building Open 34 Damp proofing/waterproofing shall comply with IBC 1803 502 S1.2 structural details Free text Cody Jones : Building Open 34 Site grading needs to meet requirements of IBC 1804.4 800 E0.1 fire alarm and symbol legends Comment Bret Stoddard : Electrical Open 57 Fire Alarm System must include voltage drop calculations, specifications for devices etc., operation matrix, and full fire alarm set of plans. Deferred submittals are acceptable. 200 C01 site utility plan Free text Kyle Baldwin : P&Z Open 5 14 200 C01 site utility plan Free text Kyle Baldwin : P&Z Open 5 28 200 C01 site utility plan Free text Kyle Baldwin : P&Z Open 5 8 200 C01 site utility plan Free text Kyle Baldwin : P&Z Open 5 19 200 C01 site utility plan Free text Kyle Baldwin : P&Z Open 5 7 200 C01 site utility plan Free text Kyle Baldwin : P&Z Open 5 76 Parking stalls 200 C01 site utility plan Callout Kyle Baldwin : P&Z Open 5 Current location does not work for current garbage trucks. They are right hand pickup only 200 C01 site utility plan Callout Kyle Baldwin : P&Z Open 5 Full width driveway required for forecode (24') 200 C01 site utility plan Free text Kyle Baldwin : P&Z Open 5 Please include: Landscape Plan (see section 3.04.060,5,c) Sidewalk connectivity to public sidewalks (see section 6.00.090,B) Snow storage areas (see section 3.04.060,4) Permissible lot coverage (see section 6.01.090) Central Features and Community Spaces (6.00.040) 200 C01 site utility plan Callout Joel Gray : PW Open 5 Sidewalk must be ADA Compliant. 200 C01 site utility plan Callout Joel Gray : PW Open 5 Abandon existing service at main line. 200 C01 site utility plan Callout Joel Gray : PW Open 5 Sampling manhole required. Report Date: 08.11.2021 Approval of plans does not constitute approval of variance from code Page 2 of 3 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 200 C01 site utility plan Callout Joel Gray : PW Open 5 Gates must open 180 degrees. Report Date: 08.11.2021 Approval of plans does not constitute approval of variance from code Page 3 of 3 Powered by TCPDF (www.tcpdf.org) with sprinkler system Building will be located in flood zone, will need flood certifi c a t e . S e a t i n g a t t a b l e s , c o u n t e r s , a n d w o r k a r e a s c o m p l y w i t h I B C s e c t i o n 1 1 0 9 . 1 1 <12''SD <12''SD <12 ' ' S D <12 ' ' S D <12 ' ' S D <12 ' ' S D <1 2 ' ' S D <1 2 ' ' S D <1 2 ' ' S D <1 2 ' ' S D 6''W 6''W 6''W 6''W 6''W 4''SS>4''SS>4''SS>4''SS>4''SS> 1''LW 1''LW 1''LW 1''LW OH P OH P OH P OH P OH P OH P OH P OH P O H P EP EP EP EPEP EP EP EP EP EP EP EP EP EP E P E P E P EP W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS N89°48'50"E 360.41' S0 0 ° 1 3 ' 4 2 " E 1 3 8 . 0 0 ' S89°48'50"W 360.52' N0 0 ° 1 1 ' 1 0 " W 1 3 8 . 0 0 ' (8 0 1 ) 5 5 8 - 2 4 1 5 - C E L L RI V E R T O N , 11 7 7 2 S O U T H S T O N E C R E S T L A N E BR I A N D . R U S S E L L AR C H I T E C T S , I N C . (8 0 1 ) 3 0 7 - 0 8 0 0 UT A H 8 4 0 6 5 01 EXIST. SANITARY SEWER 02 EXIST. SANITARY SEWER MANHOLE 03 EXIST. WATER LINE 04 EXIST. FIRE HYDRANT 05 EXIST. WATER VALVE 06 EXIST. WATER METER & SERVICE LINE, ABANDON IN PLACE 07 EXIST. LIGHT POLE, RETAIN & PROTECT 08 EXIST. POWER POLE, RETAIN & PROTECT 09 EXIST. TRANSFORMER, RETAIN & PROTECT 10 NEW BUILDING; RE: ARCH PLANS 11 NEW 4" SANITARY SEWER SERVICE; RE: MECH PLANS FOR CONNECTION 12 NEW 4" TRAFFIC RATED SEWER CLEANOUT 13 1500 GALLON TRAFFIC RATED GREASE TRAP 14 NEW INLET BOX; RE: B5/SHEET C-04 15 NEW 4' CONCRETE CROSS DRAIN; RE: CITY OF REXBURG STANDARD DRAWING 7 16 NEW FLAT CURB & GUTTER; RE: A1/SHEET C-04 17 NEW COMBINATION CURB & SIDEWALK; RE: A4/SHEET C-04 18 NEW SIDEWALK; RE: A3/SHEET C-04 19 NEW ADA RAMP; RE: B3/SHEET C-04 20 4" YELLOW PAVEMENT MARKING 21 ASPHALT PAVEMENT; RE: C1/SHEET C-04 22 NEW DUMPSTER PAD/ENCOLSURE; RE: ARCH PLANS 23 ADA PARKING PAVEMENT MARKINGS 24 12" PVC STORM DRAIN 25 EXIST. SIDEWALK, RETAIN & PROTECT 26 RADIO READ 2-INCH WATER METER; RE: CITY OF REXBURG STANDARD DRAWING 14 27 REMOVE EXIST. PAVEMENT 28 NEW SIGN; RE: ARCH PLANS 29 NEW LIGHT; RE: ELECT SITE PLAN 30 NEW TRANSFORMER; RE: ELECT SITE PLAN 31 1" POLY IRRIGATION WATER SERVICE w/ APPROVED BACK-FLOW PREVENTOR 32 NEW STORMTECH MC-3500 CHAMBERS, 17 REQ'D (1 ROW OF 9, 1 ROW OF 8) 33 NEW STORM DRAIN MANHOLE; RE: ISPWC SD-501 34 2" POLY DOMESTIC WATER LINE 35 SADDLE TAP EXIST. SEWER LINE 36 6-INCH CLASS 51 D.I. FIRE WATER LINE 37 8" x 6" HOT TAP WITH 6" GATE VALVE 38 2" GATE VALVE CONSTRUCTION KEYNOTES 0 SCALE: 1"= (SCALE FOR 24"x36" PRINTS ONLY) 20' 402020 DIAL 811 OR TOLL FREE AT 1-800-342-1585 Know what's Call before you dig. below. N. 2 n d . E . S T . THIS SITE PLAN CONFORMS TO AN ACTUAL SURVEY THAT WAS PERFORMED ON THE GROUND BY A LICENSED LAND SURVEYOR IN AND FOR THE STATE OF IDAHO. IT IS THE OWNER’S RESPONSIBILITY TO CONSTRUCT ALL STRUCTURES SHOWN ON THIS SITE PLAN IN ACCORDANCE WITH SAID SURVEY. BASIS OF BEARING HORIZONTAl - NORTH 2nd EAST CHURCH SUBDIVISION PROJECT BENCHMARK POINT NO. 1 SET MAG NAIL ELEV.=4868.16 NGVD 1929 RM 3 ELEV=4651.1 REQUIRED STORM WATER TO RETAIN ON SITE WAS CALCULATED USING THE FOLLOWING VALUES: C (weighted)= 0.83 INTENSITY (i)= 0.9 in/hr AREA (A)= 1.14 acres Q = CiA = 0.85 cfs T (Storm Duration)= 1 hr = 3600 seconds V = CiAT = 3,071 cu. ft. SITE STORM WATER RETENTION REQ'D - 3,071 cu. ft. POND STORAGE PROV'D -3,229 cu. ft. 01 STORMWATER NOTE SURVEY NOTE 02 03 04 05 06 07070707 08 08 09 14 14 1414 15 16 16 16 16 17 17 17 18 18 19 20TYP 20TYP 20TYP 20TYP 20TYP 16 16 10 21 21 21 22 23 24 24 24 25 27 28 32 33 # 24 24 38 11 13 36 31 100 LF @ 0.25% 34 26 37 CB-1 GRATE - 4865.00 INV. - 4862.00 CB-2 GRATE - 4865.50 INV. - 4861.75 110 LF @ 0.82% CB-3 GRATE - 4863.85 INV. - 4860.85 68 LF @ 0.44% CB-4 GRATE - 4863.55 INV. - 4860.55 SDMH-1 RIM - 4863.93 INV. IN - 4860.51 24" INV. OUT (CHAMBERS ROW) - 4858.00 24" INV. OUT (ISOLATOR ROW) - 4857.50 SUMP ELEV. - 4856.50 20 TYP TOP OF CHAMBERS - 4861.85 ISOLATOR ROW SUBGRADE - 4856.85 CHAMBERS ROW SUBGRADE - 4857.35 15 LF @ 0.27% 53' 79 ' 12 ' 105.3' 6. 0 ' 6.0' 20.0' 9. 0 ' 6.0' 20.0'29.5'20.0' 9' 8.0' 8.0'8.0' 8.0' 4. 0 ' 20 . 0 ' 40.0'30.0'40.0' 30 . 0 ' 9.0' 33.3' 22 . 7 ' 16 . 5 ' 35 . 0 ' AC C E S S EA S E M E N T 20.0' P.U.E. 29.5' 7629 T OHADIFOETA T S ER DEREGIS GREBEIFRFF J E E R E E N I G NEONALSI E S R O F P 7629 T OHADIFOETA T S ER DEREGIS GREBEIFRFF J E R E E N I G NEONALSI E S R O F P 06/22/21 946 OXBOW LANE IDAHO FALLS, IDAHO 83404 208-220-6431 32.82 ft 14 28 8 19 7 76 Parking stalls Current location does not work for current garbage trucks. They are right hand pickup only Full width driveway required for forecode (24') Please include: Landscape Plan (see section 3.04.060,5,c) Sidewalk connectivity to public sidewalks (see section 6.00.090,B) Snow storage areas (see section 3.04.060,4) Permissible lot coverage (see section 6.01.090) Central Features and Community Spaces (6.00.040) 20 . 0 0 f t Sidewalk must be ADA Compliant. Abandon existing service at main line. Sampling manhole required. Gates must open 180 degrees. Glass and glazing will need to meet requirements of Chapter 24. C e i l i n g t o b e b u i l t t o m a n u f a c t u r e r s s p e c i f i c a t i o n s . R o o f a n d r o o f f i r e c l a s s i f i c a t i o n ? A l l o t h e r c o n c e a l e d a r e a s n e e d t o b e f i r e b l o c k e d / d r a f t s o p p e d i f a n y . P a n i c h a r d w a r e t o b e i n s t a l l e d o n E g r e s s d o o r s , o r r e q u i r e d s i g n a g e . Damp proofing/waterproofing shall comply with IBC 1803 Site grading needs to meet requirements of IBC 1804.4 1FIRE ALARM RISER DIAGRAM AND NOTES23 4 5 A B B R E V I A T I O N S 6 8 1 2 3 4 57 6 1 2 OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHPOHP W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS 1 OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS L U M I N A I R E S C H E D U L E S y m b o l L a b e l Q t y F i l e L u m e n s L L F W a t t s C a t a l o g N u m b e r D e s c r i p t i o n L a m p L E 0 1 1 3 1 0 3 6 0 . 8 1 8 . 8 E L 0 3 5 A b s o l u t e 0 . 8 1 3 6 . 6 E L 0 1 4 A b s o l u t e 0 . 8 1 1 5 . 6 S 4 H 8 6 1 A b s o l u t e 0 . 8 1 8 6 S 4 H 5 3 1 A b s o l u t e 0 . 8 1 5 3 S 5 Q 8 6 2 A b s o l u t e 0 . 8 1 8 6 5 9 1 1 - 1 A A - T C r e e C X x 1 5 x x M e d i u m S L I M 3 7 Y G N L E D 1 3 Y S B / S P O T R E F / C L E A R L E N S O S Q - A - x x - 4 M E - B - 3 0 K - U L x x x x x w / O S Q - B L S M F C O N F I G U R E D F R O M O S Q - A - x x - 4 M E - U - 5 7 K - U L x x x x x w / O S Q - B L S L F O S Q - A - x x - 4 M E - Z - 3 0 K - U L x x x x x w / O S Q - B L S M F C O N F I G U R E D F R O M O S Q - A - x x - 4 M E - U - 5 7 K - L x x x x x w / O S Q - B L S L F O S Q - A - x x - 5 S Q - B - 3 0 K - U x - x x x x x C O N F I G U R E D F R O M O S Q - A - x x - 5 S Q - U - 5 7 K - U L - x x x x x 5 9 1 1 - 1 A A - T C r e e C X x 1 5 x x M e d i u m ( F C N 1 3 9 2 7 _ B A R B A R A - W - - P F - V E R O 1 3 - 1 8 _ ( C X A 1 5 2 0 ) C X A 1 5 2 0 _ ( C X A 1 5 2 0 - 3 0 F - N 4 - N 0 H - 0 0 0 0 1 ) _ ( 4 4 1 _ T y p _ L 1 ) _ ( C 1 3 7 0 9 _ P F - S O C K E T - V E R O 1 3 - 1 8 ) _ 1 0 3 6 . 1 4 l m @ 2 5 0 m A _ P = 8 . 8 2 5 W _ I = 0 . 2 5 A ) C A S T B R O W N P A I N T E D M E T A L H O U S I N G , E X T R U D E D 2 - P I E C E D I F F U S E M E T A L H E A T S I N K , 1 W H I T E C I R C U I T B O A R D W I T H 1 6 L E D S , M O L D E D P L A S T I C R E F L E C T O R W I T H S P E C U L A R F I N I S H , C L E A R F L A T P R I S M A T I C G L A S S L E N S I N C A S T 2 - P I E C E B R O W N P A I N T E D M E T A L L E N S R E T A I N I N G B R A C K E T . L E N S P R I S M S D O W N . C A S T F I N N E D M E T A L H O U S I N G , O N E C I R C U I T B O A R D W I T H O N E L E D , S P U N S E M I - S P E C U L A R M E T A L R E F L E C T O R , C L E A R F L A T G L A S S L E N S I N C A S T B L A C K P A I N T E D M E T A L T R I M R I N G . C r e e O S Q S e r i e s A r e a L u m i n a i r e , T y p e I V M e d i u m w / B a c k l i g h t S h i e l d , B I n p u t P o w e r D e s i g n a t o r , 3 0 0 0 K C O N F I G U R E D F R O M C r e e O S Q S e r i e s A r e a L u m i n a i r e , T y p e I V M e d i u m w / B a c k l i g h t S h i e l d , U I n p u t P o w e r D e s i g n a t o r , 5 7 0 0 K C O N F I G U R E D F R O M C r e e O S Q S e r i e s A r e a L u m i n a i r e , T y p e I V M e d i u m w / B a c k l i g h t S h i e l d , U I n p u t P o w e r D e s i g n a t o r , 5 7 0 0 K C O N F I G U R E D F R O M C r e e O S Q S e r i e s A r e a L u m i n a i r e , T y p e V S q u a r e , U I n p u t P o w e r D e s i g n a t o r , 5 7 0 0 K C X A 1 5 2 0 _ ( C X A 1 5 2 0 - 3 0 F - N 4 - N 0 H - 0 0 0 0 1 ) _ ( 4 4 1 _ T y p _ L 1 ) _ ( C 1 3 7 0 9 _ P F - S O C K E T - V E R O 1 3 - 1 8 ) _ 1 0 3 6 . 1 4 l m @ 2 5 0 m A _ P = 8 . 8 2 5 W _ I = 0 . 2 5 A S I X T E E N W H I T E M U L T I - C H I P L I G H T E M I T T I N G D I O D E S ( L E D S ) , A I M E D 1 0 - D E G R E E S F R O M V E R T I C A L B A S E - U P P O S I T I O N . O N E W H I T E M U L T I - C H I P L I G H T E M I T T I N G D I O D E ( L E D ) W I T H L E D S A R R A N G E D I N A N A R R A Y O F T H R E E L I N E A R R O W S , V E R T I C A L B A S E - U P P O S I T I O N . C O N F I G U R E D F R O M M D A C O N F I G U R E D F R O M M D A X H P 7 0 5 9 1 1 C r e e C X x 1 5 x x M e d i u m - F C N 1 3 9 2 7 _ B A R B A R A - W - P F - V E R O 1 3 . . . . i e s S L I M 3 7 Y - I T L 7 6 6 9 2 . I E S G N L E D 1 3 Y S B - - R A B 0 0 2 9 6 . I E S O S Q - A - X X - 4 M E - B - 3 0 K - U L X X X X X W _ O S Q - B L S M F _ C O N F I G U R E D . i e s O S Q - A - X X - 4 M E - Z - 3 0 K - U L X X X X X W _ O S Q - B L S M F _ C O N F I G U R E D . i e s O S Q - A - x x - 5 S Q - B - 3 0 K - U x - - x x x x x _ C O N F I G U R E D . I E S