HomeMy WebLinkAboutFIRE ALARM INSPECTION REPORT - 21-00488 - Dennys - New Commercial BldgPEjJA � SECURITY SYSTEMS INC. MEMBER FIRE ALARM INSPECTION AND TESTING REPORT Testing performed in accordance with applicable NFPA 72 Standards / By NICET Certified Technicians Building occupied as Owner /Manager: Name & Number Address of Building Name of Tester .Date of Inspection Type of Inspection Notification of Testing Control Panel Manufacturer & Model # of Zones: SLC Loops: NAC's - FACP: FCPS: Total NAC's: System should be tested on Standby (battery power) for 30 min. prior to Battery Test. Battery Inspection RADIO FACP FCPS1 FCPS2 FCPS3 Location Battery Voltage Amp Hour Date on Battery FACP Inspection Yes No N/A # of Units Tested Yes No N/A Key to Panel Available All circuits checked for electrical supervision Annunciators Operating Instructions at Panel Newest Record posted at Panel All functions and buttons work properly circuit Breaker marked Red circuit Breaker Panel: # Does Alarm system meet audibility standards Smoke Detectors Trouble Signal with AC Power off System operates satisfactory on standby power at max load Control Panel checks made per manufacturer's instruction All signals operate on AC power All interfaced equipment operates (Elevators, Fans, Dampers) X Pull Stations All LED's Illuminate Name of Monitoring Company: Account # Communication Verified: N/A Equipment Tested Type of Equipment # of Units Tested Satisfactory: Satisfactory: Yes No N/A # of Units in Bldg. FCPS Power Booster Annunciators Dialer Communicator' Horns, Strobes, Bells, Chimes, Speakers, Etc. +• Smoke Detectors Heat Detectors Duct Detectors' Pull Stations / Flow Switches Tamper Switches Low/High Air Switches Antifreeze Tamper a' Ansul System 6 i Temp Sensor Problems Found: Corrections Made: Interfaced # of Units Satisfactory: Satisfactory: N/A # of Units Equipment Tested Yes No in Bldg. Ventilation Controls Elev. Recall Primary Elev. Recall Sec s. Elev. Recall Shunt Access Control Door Release Failsafe Auto Release K, Door Holders Halon System Smoke Control PIV Valve Beam Detector CO Detector This is to certify that this Fire Alarm has been properly Tested and Inspected for liability to cover the items listed in this report, according to Manufacturers Recommendation. Signature of Fire Marshal: Date: 5—h Signature of Owner or representatives Date: Signature of Certified Tester ,Z' Date: f Agency: Omni Security Systems, Inc. • P. O. Box 309 • Rigby, ID 83442 • Office 208-745-1020 • Fax: 208-745-1564