Loading...
HomeMy WebLinkAboutREDLINED PLAN - 22-00440 - Safety Provisions - RemodelAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Don Allen Don.Allen@rexburg.org 208-372-2174 Description : Safety Provisions - Remodel Address : 3475 W Hwy 33 Application Type : Document Filename : LEE ADDITION FINAL.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G-101 Free text Cody Jones : Building Open 1 IBC G-101 Free text Cody Jones : Building Open 1 Occupancy type B? Occupant load? VB construction? G-101 Free text Cody Jones : Building Open 1 If building was built as a non conditioned storage, it will need to meet energy requirements. A-101 Free text Cody Jones : Building Open 2 Landings at doors and cross slope of sidewalks not to exceed 2%. Exit signs and Exit lighting to comply with sections 1008 and 1013. A-101 Free text Cody Jones : Building Open 2 ADA restroom to meet all requirements. S-101 Free text Cody Jones : Building Open 6 Please verify existing footing is below frost depth or shallow foundation protection is installed or needs to be completed. S-301 Free text Cody Jones : Building Open 7 11 # 22-00440 Madison County - Commercial Remodel Report Date: 06.27.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) DR A W N B Y : CH K ' D B Y : SB W AC H PL O T D A T E : 5/ 1 0 / 2 0 2 2 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E CO V E R S H E E T SH E E T T I T L E : G-101 PLN# 21-07-021 5/10/2022 12 7 E . M a i n S t . S u i t e 1 1 1 Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k d e s i g n . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C AR T H U R L E E 34 7 5 I D - 3 3 RE X B U R G , I D . THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 2 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . ADDITION & REMODEL NOTEADDITION & REMODEL NOTEADDITION & REMODEL NOTEADDITION & REMODEL NOTE :::: IT IS THE RESPONSIBILITY OF THE OWNER/ BUILDER TO VERIFY THE DIMENSIONS, ROOF PITCHES, FLOOR ELEVATIONS, AND INTEGRATION OF THE OVERALL DESIGN WITH THE EXISTING STRUCTURE. INDEX OF SHEETS G-101 A-101 A-201 A-301 D-101 S-101 S-301 S-401 R-101 E-101 COVER SHEET MAIN FLOOR ELEVATIONS SECTIONS DEMOLITION PLAN FOUNDATION WALL FRAMING ROOF FRAMING DETAILS MEP MARKUP PLAN UNFINISHED SQUARE FOOTAGEUNFINISHED SQUARE FOOTAGEUNFINISHED SQUARE FOOTAGEUNFINISHED SQUARE FOOTAGE ID NEW OFFICE AREA 2,117.93 2,117.93 ft² LOCATION: MADISON COUNTY, ID. SNOW LOAD: 50 PSF WIND SPEED: 115 MPH FROST DEPTH: 36 IN. SEISMIC: D1 REGULATION: IRC 2018 LEE ADDITIONLEE ADDITIONLEE ADDITIONLEE ADDITIONIBC If building was built as a non conditioned storage, it will need to meet energy requirements. Occupancy type B? Occupant load? VB construction?