HomeMy WebLinkAboutREDLINED PLANS - 22-00699 - Mountain Archery - AdditionAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Description : Mountain Archery - Addition Address : 651 E 3000 N Application Type : Document Filename : 913-Building.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G1.1 Free text Cody Jones : Building Open 1 As per table 601, Exterior bearing walls of a type IIIB need to have a 2 hour rating. G1.1 Free text Cody Jones : Building Open 1 Concealed spaces if any need to comply with section 718. Landings at doors and cross slope of sidewalk not to exceed 2%. Need engineered steel building plans. Special inspector needs to be identified. (bolts, welding). Exit lighting and exit signs to comply with section 1008 and 1013. As per table C402.1.3 in the IECC, slabs to be insulated 24" below for unheated slab. A1.1 Free text Cody Jones : Building Open 4 As per section 706.6, In order for fire wall to terminate at roof decking a minimum of class B roof covering is required. In exception 4.3 roof decking will need to protected on each side for four feet. Penetrations of fire wall shall comply with section 714. # 22-00699 Madison County - Commercial Addition Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 09.21.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) C o n c e a l e d s p a c e s i f a n y n e e d t o c o m p l y w i t h s e c t i o n 7 1 8 . L a n d i n g s a t d o o r s a n d c r o s s s l o p e o f s i d e w a l k n o t t o e x c e e d 2 % . N e e d e n g i n e e r e d s t e e l b u i l d i n g p l a n s . S p e c i a l i n s p e c t o r n e e d s t o b e i d e n t i f i e d . ( b o l t s , w e l d i n g ) . E x i t l i g h t i n g a n d e x i t s i g n s t o c o m p l y w i t h s e c t i o n 1 0 0 8 a n d 1 0 1 3 . A s p e r t a b l e C 4 0 2 . 1 . 3 i n t h e I E C C , s l a b s t o b e i n s u l a t e d 2 4 " b e l o w f o r u n h e a t e d s l a b . As per table 601, Exterior bearing walls of a t y p e I I I B need to have a 2 hour rating. 100.2 ft100.1 ft A s p e r s e c t i o n 7 0 6 . 6 , I n o r d e r f o r f i r e w a l l t o t e r m i n a t e a t r o o f d e c k i n g a m i n i m u m o f c l a s s B r o o f c o v e r i n g i s r e q u i r e d . I n e x c e p t i o n 4 . 3 r o o f d e c k i n g w i l l n e e d t o p r o t e c t e d o n e a c h s i d e f o r f o u r f e e t . P e n e t r a t i o n s o f f i r e w a l l s h a l l c o m p l y w i t h s e c t i o n 7 1 4 . 80.0 ft