Loading...
HomeMy WebLinkAboutCOMCHECK - 22-00699 - Mountain Archery - AdditionCOMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Title: 2021 IECC Project Type:Addition Vertical Glazing / Wall Area:4% Location:Sugar City, Idaho Climate Zone:6b Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: Building Area Floor Area 1-Manufacturing Facility : Nonresidential 8000 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof: Metal Building, Standing Seam, Single Insulation Layer with Thermal Blocks (d), [Bldg. Use 1 - Manufacturing Facility] 8000 0.0 38.0 0.026 0.031 NORTH Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Manufacturing Facility] 907 0.0 38.0 0.026 0.050 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing Facility] 15 ------0.450 0.370 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Solar Bronze 6 mm, SHGC 0.32, [Bldg. Use 1 - Manufacturing Facility] (c) 207 ------0.280 0.340 Ext. Wall: Solid Concrete, 8in. Thickness, Normal Density, Furring: Wood, [Bldg. Use 1 - Manufacturing Facility] 82 0.0 0.0 0.345 0.080 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing Facility] 6 ------0.450 0.370 EAST Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Manufacturing Facility] 2440 0.0 38.0 0.026 0.050 Door: Other (U-Factor option), Swinging, [Bldg. Use 1 - Manufacturing Facility] 15 ------0.270 0.370 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Solar Bronze 6mm, SHGC 0.32, [Bldg. Use 1 - Manufacturing Facility] (c) 92 ------0.280 0.340 Ext. Wall: Solid Concrete, 8in. Thickness, Normal Density, Furring: Wood, [Bldg. Use 1 - Manufacturing Facility] 200 0.0 0.0 0.345 0.080 Door: Other (U-Factor option), Swinging, [Bldg. Use 1 - Manufacturing Facility] 6 ------0.270 0.370 SOUTH Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Manufacturing Facility] 1680 0.0 38.0 0.026 0.050 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing Facility] 15 ------0.450 0.370 Ext. Wall: Solid Concrete, 8in. Thickness, Normal Density, Furring: Wood, [Bldg. Use 1 - Manufacturing Facility] 82 0.0 0.0 0.345 0.080 Project Title: Data filename: 08/31/22Report date: 121 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing Facility] 6 ------0.450 0.370 WEST Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber (compressed at girt), [Bldg. Use 1 - Manufacturing Facility] 1759 0.0 38.0 0.026 0.050 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing Facility] 15 ------0.450 0.370 Ext. Wall: Solid Concrete, 8in. Thickness, Normal Density, Furring: Wood, [Bldg. Use 1 - Manufacturing Facility] 200 0.0 0.0 0.345 0.080 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing Facility] 6 ------0.450 0.370 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d)Thermal spacer block with minimum R-3.5 must be installed above the purlin/batt, and the roof deck secured to the purlins. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 9% better than code Project Title: Data filename: 08/31/22Report date: 122 ofPage