HomeMy WebLinkAboutCOMCHECK - 22-00699 - Mountain Archery - AdditionCOMcheck Software Version COMcheckWeb
Envelope Compliance Certificate
Project Title:
2021 IECC
Project Type:Addition
Vertical Glazing / Wall Area:4%
Location:Sugar City, Idaho
Climate Zone:6b
Construction Site:Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Building Area Floor Area
1-Manufacturing Facility : Nonresidential 8000
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Roof: Metal Building, Standing Seam, Single Insulation Layer
with Thermal Blocks (d), [Bldg. Use 1 - Manufacturing Facility]
8000 0.0 38.0 0.026 0.031
NORTH
Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Manufacturing Facility]
907 0.0 38.0 0.026 0.050
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing
Facility]
15 ------0.450 0.370
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.:
Product ID Solar Bronze 6 mm, SHGC 0.32, [Bldg. Use 1 -
Manufacturing Facility] (c)
207 ------0.280 0.340
Ext. Wall: Solid Concrete, 8in. Thickness, Normal Density,
Furring: Wood, [Bldg. Use 1 - Manufacturing Facility]
82 0.0 0.0 0.345 0.080
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing
Facility]
6 ------0.450 0.370
EAST
Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Manufacturing Facility]
2440 0.0 38.0 0.026 0.050
Door: Other (U-Factor option), Swinging, [Bldg. Use 1 -
Manufacturing Facility]
15 ------0.270 0.370
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.:
Product ID Solar Bronze 6mm, SHGC 0.32, [Bldg. Use 1 -
Manufacturing Facility] (c)
92 ------0.280 0.340
Ext. Wall: Solid Concrete, 8in. Thickness, Normal Density,
Furring: Wood, [Bldg. Use 1 - Manufacturing Facility]
200 0.0 0.0 0.345 0.080
Door: Other (U-Factor option), Swinging, [Bldg. Use 1 -
Manufacturing Facility]
6 ------0.270 0.370
SOUTH
Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Manufacturing Facility]
1680 0.0 38.0 0.026 0.050
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing
Facility]
15 ------0.450 0.370
Ext. Wall: Solid Concrete, 8in. Thickness, Normal Density,
Furring: Wood, [Bldg. Use 1 - Manufacturing Facility]
82 0.0 0.0 0.345 0.080
Project Title:
Data filename:
08/31/22Report date:
121 ofPage
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing
Facility]
6 ------0.450 0.370
WEST
Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Manufacturing Facility]
1759 0.0 38.0 0.026 0.050
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing
Facility]
15 ------0.450 0.370
Ext. Wall: Solid Concrete, 8in. Thickness, Normal Density,
Furring: Wood, [Bldg. Use 1 - Manufacturing Facility]
200 0.0 0.0 0.345 0.080
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Manufacturing
Facility]
6 ------0.450 0.370
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)'Other' components require supporting documentation for proposed U-factors.
(c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(d)Thermal spacer block with minimum R-3.5 must be installed above the purlin/batt, and the roof deck secured to the
purlins.
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2021 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Envelope PASSES: Design 9% better than code
Project Title:
Data filename:
08/31/22Report date:
122 ofPage