Loading...
HomeMy WebLinkAboutREDLINED ELECTRICAL RESPONSE - 22-00821 - Shelfology - AdditionAuthor Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Shelfology - Addition Address : 156 N 2nd E Application Type : Document Filename : 2022_03_SHELFOLOGY SHOP EXPANSION_ELEC.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments E00 - ELECTRICAL SYMBOLS & ABBREV- Callout Alex Owens : Electrical Open 1 For verification: Notes Q,R,S are above and beyond NEC requirements. Please verify this is as the engineer requires and it will be inspected accordingly. E00 - ELECTRICAL SYMBOLS & ABBREV- Free Text Alex Owens : Electrical Open 1 All electrical work to comply with 2017 NEC. # 22-00821 Commercial - Addition Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 11.08.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) 1. We recognize these requirement exceed NEC requirements but are considered good practices. Project to comply with Notes Q, R, & S as specified. 2. A GENERAL NOTE will be included to require compliance with 2017 NEC. J PCDS M F CO N D U I T C O N T I N U A T I O N CO N D U I T C O N C E A L E D I N W A L L O R C E I L I N G CO N D U I T E X I S T I N G CO N D U I T C O N C E A L E D U N D E R G R O U N D CO N D U I T S T U B D O W N ST U B T H R O U G H CO N D U I T S T U B U P JU N C T I O N B O X ( N E W , E X I S T I N G , D E M O ) EL E C T R I C A L D I S T R I B U T I O N P A N E L B O A R D EQ U I P M E N T E N C L O S U R E A S N O T E D SI M P L E X R E C E P T A C L E DU P L E X R E C E P T A C L E ( N E W , E X I S T I N G , D E M O ) DO U B L E D U P L E X R E C E P T A C L E OV E R -CO U N T E R R E C E P T A C L E CO N T R O L L E D R E C E P T A C L E EM E R G E N C Y E X I T S I G N W I T H B A T T E R Y B A C K U P : S H A D E D QU A R T E R O F S Y M B O L I N D I C A T E S L I G H T E D ' E X I T ' O N T H A T FA C E A R R O W S I N D I C A T E L I G H T E D D I R E C T I O N A L A R R O W ON T H A T F A C E . C O N N E C T T O U N S W I T C H E D L O C A L LI G H T I N G C I R C U I T EM E R G E N C Y L I G H T I N G ( S U R F A C E , R E C E S S E D ) CO N N E C T T O U N S W I T C H E D L O C A L L I G H T I N G C I R C U I T FI X T U R E S W I T H H A L F -SH A D I N G A R E E M E R G E N C Y L I G H T S W I T H BA T T E R Y B A C K U P . B A T T E R Y B A C K U P S H A L L P R O V I D E MI N I M U M 1 1 0 0 L U M E N S P E R F I X T U R E F O R 9 0 M I N U T E S . EM E R G E N C Y B A T T E R Y U N I T S H A L L B E C O N N E C T E D T O UN S W I T C H E D L O C A L L I G H T I N G C I R C U I T . F I X T U R E S S H A L L B E SW I T C H E D W I T H R O O M L I G H T S . F I X T U R E S T O R E M A I N O N A T LO S S O F P O W E R . F I X T U R E S W I T H ' N L ' S H A L L B E EM E R G E N C Y / N I G H T L I G H T S C O N N E C T E D F O R 2 4 H O U R OP E R A T I O N . 2X 4 L I G H T F I X T U R E PE N D A N T F I X T U R E RE C E S S E D D O W N L I G H T F I X T U R E WA L L M O U N T E D F I X T U R E LI G H T F I X T U R E C A L L O U T E J XX SW I T C H X = 2 - DO U B L E P O L E -DO U B L E T H R O W 3 - TH R E E -WA Y 3 - FO U R -WA Y D - DI M M E R HP - HO R S E P O W E R R A T E D S W I T C H W I T H T H E R M A L OV E R L O A D S S I Z E D A S R E Q U I R E D B Y E Q U I P M E N T LA B E L R A T I N G K - KE Y O P E R A T E D OV - LO W V O L T A G E M O M E N T A R Y O V E R R I D E S W I T C H OS - OC C U P A N C Y S E N S O R P A S S I V E I N F R A R E D W A L L SW I T C H , W I T H A 3 0 M I N U T E T I M E D E L A Y , P R O V I D E WI T H S T A I N L E S S S T E E L F A C E P L A T E P - NE O N P I L O T L I G H T L - LI G H T E D S W I T C H T - TI M E R A S N O T E D W - WI R E L E S S S W I T C H WP - WE A T H E R P R O O F SH E E T N O T E C A L L O U T RE V I S I O N D E L T A X ## # # - # # 1 SP E C I A L E L E C T R I C A L C O N N E C T I O N : CO O R D I N A T E R E Q U I R E M E N T S W I T H E Q U I P M E N T B E I N G S E R V E D MO T O R C O N N E C T I O N ST A R T E R O R C O N T A C T O R : SI Z E A S R E Q U I R E D B Y E Q U I P M E N T M A N U F A C T U R E R CO M B I N A T I O N M O T O R S T A R T E R / D I S C O N N E C T : SI Z E A S R E Q U I R E D B Y E Q U I P M E N T M A N U F A C T U R E R DI S C O N N E C T S W I T C H : SI Z E A S R E Q U I R E D B Y E Q U I P M E N T M A N U F A C T U R E R F= F U S E D , B L A N K = U N F U S E D SW I T C H / D I S C O N N E C T C O N F I G U R A T I O N D E S I G N A T I O N NU M B E R O F P O L E S AM P E R E R A T I N G O F T H E S W I T C H NE M A C L A S S I F I C A T I O N TH E R M O S T A T O R T E M P E R A T U R E S E N S O R : S E E ME C H A N I C A L D R A W I N G S F O R L O C A T I O N S F U R N I S H A N D IN S T A L L B A C K B O X A N D 1 " C T O A B O V E A C C E S S I B L E C E I L I N G . CO O R D I N A T E I N S T A L L A T I O N W I T H M E C H A N I C A L SM O K E D A M P E R : S E E M E C H A N I C A L D R A W I N G S F O R LO C A T I O N S V E R I F Y R E Q U I R E M E N T S W I T H M E C H A N I C A L AN D F I R E P R O T E C T I O N F U R N I S H A N D I N S T A L L A L L EL E C T R I C A L R E Q U I R E D F O R C O M P L E T E O P E R A T I O N A L SY S T E M DU C T T Y P E S M O K E D E T E C T O R : S E E M E C H A N I C A L DR A W I N G S F O R L O C A T I O N S V E R I F Y R E Q U I R E M E N T S W I T H ME C H A N I C A L A N D F I R E P R O T E C T I O N F U R N I S H A N D IN S T A L L A L L E L E C T R I C A L R E Q U I R E D F O R C O M P L E T E OP E R A T I O N A L S Y S T E M ME C H A N I C A L E Q U I P M E N T C A L L O U T 1 / 3 0 / 3 XX XX T TS D SD J J A/ V GF C I R E C E P T A C L E GF C I O V E R -CO U N T E R R E C E P T A C L E GF C I C O N T R O L L E D R E C E P T A C L E W E A T H E R P R O O F G F C I R E C E P T A C L E IS O L A T E D G R O U N D R E C E P T A C L E US B C H A R G E R / D U P L E X R E C E P T A C L E OV E R -CO U N T E R U S B C H A R G E R / D U P L E X R E C E P T A C L E CO N T R O L L E D U S B C H A R G E R / D U P L E X R E C E P T A C L E FL O O R R E C E P T C L E S : FL U S H W I T H C O V E R FL U S H F L O O R B O X DU P L E X R E C E P T A C L E , C O M M / D A T A , A / V CE I L I N G R E C E P T A C L E : FL U S H W I T H C E I L I N G HO M E R U N 2X 2 L I G H T F I X T U R E ST R I P L I G H T F I X T U R E WA L L S C O N C E RE C E S S E D S T E P F I X T U R E BO L L A R D F I X T U R E PO S T T O P L I G H T F I X T U R E , P O L E , A N D B A S E SW I T C H 1 2 0 / 2 7 7 V O L T , 2 0 A M P CE I L I N G O C C U P A N C Y S E N S O R OS IN T E R I O R D A Y L I G H T S E N S O R EX T E R I O R P H O T O C E L L TE L E P H O N E T E R M I N A L B O A R D ( P L A N V I E W ) SI G N A L O U T L E T S S Y S T E M N O T E S : S Y S T E M S A R E RA C E W A Y O N L Y F O R T H I S C O N T R A C T O R U O N . 4 " S Q U A R E BO X M I N I M U M W I T H S I N G L E G A N G M U D R I N G U O N . 1 " MI N I M U M C O N D U I T S I Z E F R O M B O X T O N E A R E S T AC C E S S I B L E C E I L I N G . TE L E P H O N E -DA T A O U T L E T W E A T H E R P R O O F G F C I R E C E P T A C L E OV E R -CO U N T E R W E A T H E R P R O O F G F C I R E C E P T A C L E HO R I Z O N T A L F A C E P L A T E SM O K E / C O D E T E C T O R : K I D D E i 1 2 0 1 0 S C O ( O R A P P R O V E D E Q U I V A L E N T ) SD 7 A 8 B 65 7 CD 86 5 2 43 1 AB243C DWG‐EFFECTIVE DATE:REVDATE:DESIGN:APPROVED:NAME AND DATE FOR CURRENT RELEASE ONLY1D XL ENGINEERING IDAHO FALLS, IDAHOXL ENGINEERING 5257 WILD DUNES LN IDAHO FALLS, ID 83404ELECTRICAL ENGINEER MARK OWENS (208) 709 -3111 MOWENS@XLENGINEERING.NETMECHANICAL ENGINEER JOHN GODAK (208) 339 -4907 JGODAK@XLENGINEERING.NET M. Owens M. Owens E00Shelfology Shop Expansion 156 N 2nd E Rexburg, ID 83440 ELECTRICAL SYMBOLS & ABBREV.10/15/22 10/15/22 EL E C T R I C A L A B B R E V I A T I O N S SY M B O L S _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ GENERAL NOTES: DR A W I N G I N D E X EL E C T R I C A L E0 0 E L E C T R I C A L S Y M B O L S & A B B R E V . E0 1 E N E R G Y C O M P L I A N C E F O R M S E1 1 L I G H T I N G & P O W E R P L A N S - F U L F I L L M E N T E1 2 L I G H T I N G P L A N L E V E L 2 E2 1 P O W E R P L A N - L E V E L 1 F U L F I L L M E N T E2 2 P O W E R P L A N L E V E L 2 E2 3 P O W E R P L A N R O O F E3 1 M E C H A N I C A L P O W E R P L A N L E V E L 1 E3 2 M E C H A N I C A L P O W E R P L A N L E V E L 2 E7 1 D E T A I L S E7 2 D E T A I L S #" C S I Z E O F T R A D E S I Z E C O N D U I T . # = 1 / 2 " C , 2" C . #P N U M B E R O F P O L E S . # = 1 P , 2 P , E T C . #W N U M B E R O F W I R E S , # = 3 W , 4 W , E T C . A A M P E R E AC A L T E R N A T I N G C U R R E N T AD A A M E R I C A N S W I T H D I S A B I L I T I E S A C T AF F A B O V E F I N I S H E D F L O O R AF G A B O V E F I N I S H E D G R A D E AH J A U T H O R I T Y H A V I N G J U R I S D I C T I O N AI C A M P E R E I N T E R R U P T I N G C A P A C I T Y AL A L U M I N U M AN N A N N U N C I A T O R AU X A U X I L I A R Y AW G A M E R I C A N W I R E G A U G E C C O N D U I T CB C I R C U I T B R E A K E R CD C A N D E L L A CL G C E I L I N G CT C U R R E N T T R A N S F O R M E R CU C O P P E R DC D I R E C T C U R R E N T DP D T D O U B L E P O L E , D O U B L E T H R O W DP S T D O U B L E P O L E , S I N G L E T H R O W EM T E L E C T R I C A L M E T A L L I C T U B I N G EP E X P L O S I O N P R O O F EW H E L E C T R I C W A T E R H E A T E R FF U S E FA C P F I R E A L A R M C O N T R O L P A N E L GF C I G R O U N D F A U L T C I R C U I T I N T E R R U P T E R GF I G R O U N D F A U L T I N T E R R U P T E R GN D G R O U N D HO A H A N D - O F F - A U T O HP H O R S E P O W E R HV A C H E A T I N G V E N T I L A T I O N A N D A I R CO N D I T I O N I N G I/ O I N P U T / O U T P U T IG I S O L A T E D G R O U N D IN C I N C A N D E S C E N T J- B O X J U N C T I O N B O X KC M I L T H O U S A N D C I R C U L A R M I L KO K N O C K O U T KV K I L O V O L T KV A K I L O V O L T A M P E R E KW K I L O W A T T KW H K I L O W A T T H O U R LV L O W V O L T A G E MC C M O T O R C O N T R O L C E N T E R MD S B M A I N D I S T R I B U T I O N S W I T C H B O A R D A. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE LOCALLY ADOPTED ELECTRICAL CODE, ALL LOCAL CODES, AND TO THE FULL ACCEPTANCE OF THE AUTHORITY HAVING JURISDICTION. WHENEVER THE REQUIREMENTS OF THE ELECTRICAL SPECI FICATIONS OR DRAWINGS EXCEED THOSE OF THE APPLICABLE CODES OR STANDARDS, THE REQUIREM ENTS OF THE SPECIFICATIONS AND DRAWINGS SHALL GOVERN.B. BIDDERS SHALL VIEW THE SITE AND SHALL INCLUDE ALL COSTS INCURRE D BY EXISTING CONDITIONS IN THE BID PROPOSAL. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVE S WTIH ALL RELEVANT BID DOCUMENTS, BID FORMS AND SPECIFICATIONS. ANY INCREASED COST INC URRED DUE TO FAILURE TO BECOME FAMILIAR WITH THESE DOCUMENTS SHALL BE BORNE BY THE CONT RACTOR. WORK SHALL INCLUDE ALL LABOR, EQUIPMENT, APPLIANCES, MATERIALS, TRANSPORTA TION, FACILITIES AND SERVICES NECESSARY FOR AND/OR REASONABLY INCIDENTAL TO THE COMP LETION OF ALL ELECTRICAL WORK IN STRICT COMPLIANCE WITH THE DRAWINGS AND OTHE R CONTRACT DOCUMENTS. WORK SHALL INCLUDE, BUT NOT BE NECESSARILY LIMITED T O, THE WORK SPECIFIED AND INDICATED ON DRAWINGS.C. OBTAIN ALL PERMITS, COORDINATE, FURNISH, INSTALL, CONNECT AND T EST ALL ELECTRICAL EQUIPMENT REQUIRED FOR ALL THE SYSTEMS INSTALLED UNDER THIS CON TRACT TO INSURE COMPLETE AND FULLY OPERATIONAL SYSTEMS.D. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS -BUILT DRAWINGS. AS -BUILT SET OF DRAWINGS SHALL BE UPDATED DAILY AND SHALL DOCUMENT THE ACTUAL I NSTALLED CONDITION OF THE ENTIRE ELECTRICAL INSTALLATION. AS -BUILT SET OF DRAWINGS SHALL BE AVAILABLE AT ALL TIMES ON THE SITE FOR INSPECTION BY CODE OFFICIALS, OWNER, ARCH ITECT, AND ENGINEER.E. PROPOSED MODIFICATIONS OF ENGINEERED ELECTRICAL DRAWINGS SHALL BE APPROVED BY ENGINEER OF RECORD PRIOR TO PROCEEDING WITH WORK. PROPOSED CHA NGES SHALL COMPLY WITH ALL APPLICABLE CODES/JURISDICTION REQUIREMENTS. COST OF A NY ENGINEERING/REVIEW REQUIRED BY PROPOSED CHANGES SHALL BE BORNE BY ENTITY PROPOSING CHANGE.F. DESIGN IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHAL L FIELD VERIFY EXISTING CONDITIONS TO DETERMINE STATUS OF ACTUAL CONDITIONS AS THEY REL ATE TO THE SCOPE OF WORK AS SHOWN ON THESE PLANS. G. COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER TRADES.H. COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL ELECTRICA L EQUIPMENT AND DEVICES WITH THE ARCHITECTURAL ELEVATIONS AND DETAILS PRIOR TO ROUGH -IN.I. CONTRACTOR SHALL COORDINATE WITH WALL TYPES AND FURNISH AND INS TALL EXTENSION RINGS AS REQUIRED. (I.E. WALLS WITH TWO LAYERS OF GYP BOARD).J. ALL MATERIALS AND EQUIPMENT FURNISHED TO THE PROJECT SHALL BE N EW AND SHALL BEAR THE LISTING LABEL OF A NATIONALLY RECOGNIZED TESTING LABORATORY (NR TL), WHERE APPLICABLE.K. ALL ELECTRICAL BOXES, FITTINGS AND CABINETS SHALL BE OF STEEL C ONSTRUCTION, GALVANIZED OR POWDER COATED, NEMA 1 TYPE, UON.L. ALL DEVICES (SWITCHES/RECEPTACLES/TELECOMMUNICATIONS) SHALL BE WHITE AND COVERPLATES SHALL BE BRUSHED STAINLESS STEEL, UON.M. ALL CIRCUIT BREAKERS SUPPLYING MOTOR LOADS SHALL BE HACR RATED.N. ALL ELECTRICAL DEVICES AND TERMINALS SHALL BE RATED 75°C MINIMU M.O. ALL CONDUCTORS SHALL BE STRANDED COPPER, 600 VOLT RATED. INSULA TION TYPE SHALL BE THHN/THWN, FULLY COLOR CODED WITH GAUGE, TYPE AND MANUFACTURER MARKED EVERY 24" ALONG. CONDUCTOR COLOR CODE SHALL BE AS FOLLOWS:208Y/120 VOLT SYSTEM 480Y/277 VOLT SYSTEM PHASE A -BLACK PHASE A -BROWN PHASE B -RED PHASE B -ORANGE PHASE C -BLUE PHASE C -YELLOW NEUTRAL -WHITE NEUTRAL -GRAY GROUND -GREEN GROUND -GREEN P. MINIMUM SIZE WIRE FOR POWER AND LIGHTING CIRCUITS SHALL BE #12 AWG, UON. CONDUCTOR SIZE SHALL BE CONTINUOUS THROUGHOUT THE ENTIRE LENGTH OF THE CIRCUIT .Q. ALL CIRCUITS SHALL HAVE AN INDEPENDENT NEUTRAL CONDUCTOR. NO E DISON STYLE SHARED NEUTRAL CONDUCTORS ARE ALLOWED.R. ALL CONDUITS SHALL CONTAIN A GROUND CONDUCTOR SIZED PER NEC.S. ALL POWER AND LIGHTING CONDUCTORS SHALL BE ROUTED IN 3/4" CONDU IT MINIMUM. NO MC TYPE CABLE IS ALLOWED WITH THE EXCEPTION OF CEILING WHIPS 6' OR LESS .T. CONDUIT AND WIRE FOR FEEDER OR BRANCH CIRCUITS SHALL NOT BE RUN ON OR ABOVE THE ROOF. ELECTRICAL SERVICES FOR ROOF MOUNTED EQUIPMENT ARE TO BE RUN IN A STRAIGHT LINE FROM THE ROOF PENETRATION TO THE ELECTRICAL CONNECTION FOR THE UNIT SERVED.U. ROUTE ALL CONDUIT HOME RUNS TO PANELS OVERHEAD AND ABOVE ACCESS IBLE CEILINGS WHERE AVAILABLE.V. INSTALL CONDUIT A MINIMUM OF 4" BELOW BOTTOM OF CONCRETE SLAB W HERE RUNNING UNDER FLOOR. ALL ELBOWS SHALL BE RIGID METAL CONDUIT OR INTERMEDIATE METAL CONDUIT.W. ALL EQUIPMENT, SWITCHING DEVICES AND PANELS SHALL BE MOUNTED SO AS TO BE ACCESSIBLE AND SHALL BE MOUNTED PLUMB AND SQUARE WITH WALLS.X. BOXES MOUNTED IN A COMMON WALL SHALL BE OFFSET A MINIMUM OF 12" OR MOUNTED IN ADJACENT STUD SPACES. BOXES MOUNTED BACK -TO -BACK ARE NOT ALLOWED.Y. ALL ELECTRICAL EQUIPMENT, RACEWAY, FIXTURE AND DEVICE SUPPORTS SHALL BE CAPABLE OF SUSTAINING NOT LESS THAN FOUR (4) TIMES THE ULTIMATE WEIGHT OF THE OBJECT OR OBJECTS. FASTEN SUPPORTS TO THE BUILDING STRUCTURE. CONDUIT IS NOT PERM ITTED TO BE SUPPORTED FROM THE CEILING FIXTURE WIRES.Z. FURNISH AND INSTALL SAFETY WIRES AT ALL LIGHT FIXTURES INSTALLE D IN A SUSPENDED CEILING.AA. MOUNTING METHODS INDICATED AND REFERRED TO ARE MINIMUM CODE REQ UIREMENTS. COMPLY WITH LOCAL CODES FOR ADDITIONAL SEISMIC RESTRAINTS.BB. DEVICES AND RACEWAYS PENETRATING FIRE RATED WALLS AND FLOORS SH ALL BE SEALED WITH FIRE RESISTIVE MATERIAL, COMPATIBLE WITH CONSTRUCTION PENETRATE D, TO MAINTAIN RATING OF THE WALL. SEALANT SYSTEM SHALL BE A NRTL APPROVED SYSTEM AND I NSTALLED PER MANUFACTURER'S INSTRUCTIONS.CC. FURNISH AND INSTALL A PULL CORD IN ALL EMPTY CONDUITS.DD. MAKE ALL CONNECTIONS TO EQUIPMENT PER MANUFACTURER'S REQUIREMEN TS.EE. ALL CONDUCTORS IN ELECTRICAL PANELS, CABINETS AND EQUIPMENT SHA LL BE NEATLY TRAINED AND LACED.FF. CLEARLY LABEL ALL ACCESSIBLE CONDUIT STUBS WITH SYSTEM NAME AND LOCATION (ROOM NUMBER) WHERE THE OTHER END OF THE CONDUIT TERMINATES. USE IND ELIBLE INK. THE LABELS SHALL BE LOCATED ON THE CONDUIT IN A POSITION THAT CAN BE EASIL Y READ BY THE OWNER IN THE FUTURE.GG. ALL JUNCTION BOX COVERS WITH POWER WIRING SHALL HAVE THE PANEL AND CIRCUIT LABELED ON THE OUTSIDE SURFACE. ALL LABELS FOR EXPOSED JUNCTION BOXES IN "FINISHED AREAS" SHALL BE LABELED UTILIZING CLEAR SELF ADHESIVE LABELS PRODUCED BY A MECH ANICAL LABELING MACHINE. LABELS FOR JUNCTION BOX COVERS IN CONCEALED LOCATIONS SHALL CON SIST OF THE INFORMATION BEING NEATLY HANDWRITTEN ON THE OUTSIDE SURFACE OF THE COVER WITH A PERMANENT STYLE MARKER. JUNCTION BOX COVERS FOR FIRE ALARM AND EMERGENCY SYSTEMS SHALL BE PAINTED RED AND LABELED "FA" FOR FIRE ALARM AND "E" FO R EMERGENCY.HH. THE CONTRACTOR SHALL PROVIDE TYPED CIRCUIT PANEL DIRECTORIES FO R ALL PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT. OLD DIRECTORIES SHAL L BE RETAINED BEHIND THE NEW.AI.THE CONTRACTOR SHALL PROVIDE SUBMITTALS TO THE GENERAL CONTRACT OR FOR APPROVAL BY ARCHITECT AND ENGINEER PRIOR TO ORDERING EQUIPMENT. SUBMITTALS SHALL CONSIST OF CATALOG CUT DESIGNATING PART NUMBERS TO BE SUPPLIED FOR EACH TYPE OF THE FOLLOWING: ELECTRICAL GEAR, LIGHT FIXTURES, BALLASTS, DRIVERS, LAMPS, DEVICES AND COVERPLATES. MF R M A N U F A C T U R E R ML O M A I N L U G O N L Y N/ A N O T A P P L I C A B L E NC N O R M A L L Y C L O S E D NE C N A T I O N A L E L E C T R I C A L C O D E NE M A N A T I O N A L E L E C T R I C A L M A N U F A C T U R E R S AS S O C I A T I O N NE S C N A T I O N A L E L E C T R I C A L S A F E T Y C O D E NO N O R M A L L Y O P E N NO . N U M B E R NR T L N A T I O N A L L Y R E C O G N I Z E D T E S T I N G LA B O R A T O R Y - A S D E F I N E D B Y O S H A O. H . O P P O S I T E H A N D - M I R R O R E D O R R O T A T E D LA Y O U T OC O V E R C O U N T E R T O P B A C K S P L A S H - CO O R D I N A T E I N S T A L L A T I O N OS H A O C C U P A T I O N A L S A F E T Y A N D H E A L T H AD M I N I S T R A T I O N PF P O W E R F A C T O R PH P H A S E RE V R E V I S I O N RT U R O O F T O P U N I T SP D T S I N G L E P O L E , D O U B L E T H R O W SP S T S I N G L E P O L E , S I N G L E T H R O W SS T S O F T S T A R T / S T O P M O T O R S T A R T E R TT B T E L E P H O N E T E R M I N A L B O A R D TV S S T R A N S I E N T V O L T A G E S U R G E S U P P R E S S O R TY P T Y P I C A L UO N U N L E S S O T H E R W I S E N O T E D UP S U N I N T E R R U P T A B L E P O W E R S U P P L Y US B U N I V E R S A L S E R I A L B U S V V O L T A G E VA V O L T - A M P E R E VF D V A R I A B L E F R E Q U E N C Y M O T O R D R I V E WP W E A T H E R P R O O F XF M R T R A N S F O R M E R XF R T R A N S F E R S W I T C H REVISION H ISTORY REVDATEDESCRIPTION 010/15/22RELEASED FOR CONSTRUCTION 10/15/2022 7 A 8 B 65 7 CD 86 5 2 43 1 AB243C DWG‐EFFECTIVE DATE:REVDATE:DESIGN:APPROVED:NAME AND DATE FOR CURRENT RELEASE ONLY1D XL ENGINEERING IDAHO FALLS, IDAHOXL ENGINEERING 5257 WILD DUNES LN IDAHO FALLS, ID 83404ELECTRICAL ENGINEER MARK OWENS (208) 709 -3111 MOWENS@XLENGINEERING.NETMECHANICAL ENGINEER JOHN GODAK (208) 339 -4907 JGODAK@XLENGINEERING.NET M. Owens M. Owens E01Shelfology Shop Expansion 156 N 2nd E Rexburg, ID 83440 ENERGY COMPLIANCE FORMS10/15/22 10/15/22REVISION H ISTORY REVDATEDESCRIPTION 010/15/22RELEASED FOR CONSTRUCTION 10/15/2022 PC F F F F OW N E R F U R N I S H E D L I G H T I N G F I X T U R E S EN V I S I O N - LE D -LH B -2F T -3M 1 6 5 -WH -F -50 K 16 5 W , 1 2 0 V ( T Y P I C A L O F 8 ) CI R C U I T A L L H O M E R U N S T O E X I S T I N G P A N E L W I T H A V A I L A B L E C A P A C I T Y US E S P A R E C I R C U I T B R E A K E R S O R S U P P L Y C O M P A T I B L E C I R C U I T B R E A K E R (S ) I N A V A I L A B L E S P A C E ( S ) (T Y P I C A L O F A L L ) LI T H O N I A - DS X W 1 L E D 2 0 C 1 0 0 0 4 0 K T 3 M M V O L T P E D D B X D MU L E - ME R U L E D A C E M D B C W LI T H O N I A - EC B G L E D M 6 LI T H O N I A - EU 2 L M 1 2 FU S E D D I S C O N N E C T S W I T C H F O R A I R C O M P R E S S O R QU I N C Y - QG D 4 0 40 H P , 5 2 A ( 1 5 3 . 5 A M A X ) , 4 8 0 V , 3 -PH A S E (T Y P I C A L O F 4 ) CI R C U I T A L L H O M E R U N S T O E X I S T I N G P A N E L W I T H A V A I L A B L E C A P A C I T Y US E S P A R E C I R C U I T B R E A K E R S O R S U P P L Y C O M P A T I B L E C I R C U I T B R E A K E R (S ) I N A V A I L A B L E S P A C E ( S ) (T Y P I C A L O F A L L ) 7 A 8 B 65 7 CD 86 5 2 43 1 AB243C DWG‐EFFECTIVE DATE:REVDATE:DESIGN:APPROVED:NAME AND DATE FOR CURRENT RELEASE ONLY1D XL ENGINEERING IDAHO FALLS, IDAHOXL ENGINEERING 5257 WILD DUNES LN IDAHO FALLS, ID 83404ELECTRICAL ENGINEER MARK OWENS (208) 709 -3111 MOWENS@XLENGINEERING.NETMECHANICAL ENGINEER JOHN GODAK (208) 339 -4907 JGODAK@XLENGINEERING.NET M. Owens M. Owens E11Shelfology Shop Expansion 156 N 2nd E Rexburg, ID 83440 LIGHTING & POWER PLANS -FULFILLMENT10/15/22 10/15/22 NO R T H GENERAL NOTES:SHEET NOTES:## ##-## NO R T H A. ALL CONDUITS WITH CIRCUIT CONDUCTORS SHALL HAVE A COPPER EQUIPM ENT GROUNDING CONDUCTOR SIZED IN ACCORDANCE WITH NEC 250.B. CONTRACTOR TO VERIFY EQUIPMENT ELECTRICAL REQUIREMENTS PRIOR TO INSTALLATION OF RELATED CIRCUIT. CIRCUIT(S) ARE TO BE SIZED AS REQUIRED BY LABEL RATING.C. ELECTRICAL DEVICES NOTED WITH AN 'OC' SUBSCRIPT ARE TO BE MOUNT ED ABOVE THE COUNTER BACK SPLASH. THE BOTTOM OF THE DEVICE COVERP LATE SHALL CLEAR THE TOP OF THE BACK SPLASH. COORDINATE THE MOUNTIN G HEIGHT WITH THE MILLWORK BEING INSTALLED.D. COORDINATE HOMERUN CIRCUIT NUMBERS WITH PANEL SCHEDULES. RE: SH EET E01.E. THIS PLAN DOES NOT REFLECT COMMUNICATION EQUIPMENT. COORDINATE WITH ARCHITECT FOR THE QUANTITY AND LOCATION OF RJ -45 PORTS. THE SERVER SHALL BE LOCATED NEAR THE ELECTRICAL SERVICE ENTRANCE. ALL RJ -45 PORTS SHALL BE CONNECTED TO THE SERVER VIA DEDICATED CAT. 6A ETHERNET CABLE. CONFIRM WITH THE ARCHITECT THAT TELEPHONE AND T V WILL BE INTERNET BASED AND THAT NO COAXIAL OR COPPER TELEPHONE WIRE IS NECESSARY.F. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL TAM PER -RESISTANT (TR) RECEPTACLES IN ALL 15A AND 20A LOCATIONS PER NEC 406.12(1).G. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL ARC -FAULT CIRCUIT -INTERRUPTER (AFCI) PROTECTION PER IN ALL 15A AND 20A LOCATIONS PER NEC 210.12(A).H. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL GRO UND -FAULT CIRCUIT -INTERRUPTER (GFCI OR GFI) PROTECTION PER NEC 210.08(A). ALL SINGLE -PHASE RECEPTACLES RATED 125 -VOLT, 50 AMPS OR LESS AND THREE -PHASE RECEPACLES RATED 125 -VOLT, 100 AMPS OR LESS SHALL BE GFCI PROTECTED. RECEPTACLES THAT ARE INACCESSIBLE ABOVE OR BEHIND APPLIANCES SHALL BE PROTECTED WITH GFCI PROTECTED CIRCUIT BREAK ERS AT THE SOURCE PANEL. I. PROVIDE COMBINATION EXIT/EGRESS LIGHTING AS SHOWN. LIGHT BARS S HALL BE AIMED TO ILLUMINATE THE EGRESS PATH WITH ARROW/CHEVRON INDIC ATING THE DIRECTION TO THE EXIT.J. DAYLIGHT ZONE(S) ARE NOT REQUIRED TO HAVE DAYLIGHT -RESPONSIVE CONTROLS DUE TO AREA CONTAINING LESS THAN 150 TOTAL WATTS OF GENERAL LIGHTING PER IECC C405.2.3. K. INTERIOR LIGHTING IS CONTROLLED BY OCCUPANCY SENSOR OR DAYLIGHT SENSOR CONTROLS (SOME CEILING MOUNTED WIDE -AREA CONTROLS AND OTHERS WALL MOUNTED CONTROLS). A LOWER CASE LETTER "x" INDICAT ES THE ZONE OF CONTROL WHEN MORE THAN ONE CONTROLLER IS PRESENT IN A COMMON SPACE.L. OCCUPANT SENSOR CONTROL FUNCTION: a. AUTOMATICALLY TURN OFF LIGHTS WITHIN 30 MINUTES OF ALL OCCUPANT S LEAVING THE SPACE. b. BE MANUAL ON OR CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING O N TO NOT MORE THAN 50 PERCENT POWER. c. SHALL INCORPORATE MANUAL CONTROL TO ALLOW OCCUPANTS TO TURN LIGHTS OFF. 1/ 4 " = 1 ' - 0 " 1 E1 1 - L I G H T I N G P L A N - L E V E L 1 F U L F I L L M E N T 1/ 4 " = 1 ' - 0 " 2 E2 1 - P O W E R P L A N - L E V E L 1 F U L F I L L M E N T REVISION H ISTORY REVDATEDESCRIPTION 010/15/22RELEASED FOR CONSTRUCTION 10/15/2022