Loading...
HomeMy WebLinkAboutBACKUP INTERFACE - 23-00159 - 1000 Westwood Dr - Solar PanelsSolarEdge Home Backup Interface For North America BI-EUSGN-02 / BI-NUSGN-02 12 YEAR WARRANTY Backup Interface for Flexible Backup 1 Automatically proVides backup power to home loads in the event of grid interruption 1 FuF flexibility in which loads to back up —the entire home or selected loads Scalable solution to support higher power and higher capacity(' I1 Requires supporting irrverterf rmware solaredge.com Built-in Auto Transformer and Energy Meter for easier and faster installation 1 Seamless integration with the SolarEdge Home Hub Inverter to manage and monitor both PV generation and energy storage f Generator connection support('l solar.-' 1 SolarEdge Home Backup Interface For North America BI-EUSGN-02 / BI-NUSGN-02 INPUT FROM GRID AC Current I nput AC Output Voltage (Nominal] AC Output Voltage Range AC Frequency (Nominal) AC Frequency Range Microgrid Interconnection Device Rated Curennt Service Side AC Main Circuit Breaker Rated Current Seance Side AC Main Circuit Breaker Interrupt Current Grid Disconnection Switchdver Time OUTPUT TO MAIN DISTRIBUTION PANEL 200 240 211-264 60 59..3 — 50.5 200 200 N/A 10000 N/A c100 A Vac Vac Hz Hz A A A ms Maximum AC Current Output 200 A AC L-L Dutpu€ Voltage (Nominal) 240 Vac AC L L DutputVoltage Range 211-264 Vac AC Frequency (Nominal) W Hz AC Frequency Range 54.3 — WS Hz Maximum Inverters AC Current Output in Backup Operation Imbalance Compensation in Backup Operation 144 A 5000 W AC L-N Output Voltage in Backup (Nominal] 120 V AC L-N OutputVoftage Range in Backup 105-132 V AC Frequency Range in Backup 55— 55 Hz INPUT FROM INVERTER Number of Inverter Inputs Up to 3 t Maximum Rated AC Power in Or -Grid and Backup Operation 11400 W Maximum Continuous Current in On -Grid and Backup Operation 48 A. Factory Installed Inverter Input AC Circuit Breaker 40 A Upgradability Up to 3 x 63A CB1" GENERATOR(2) Maximum Rated AC Power 22500 W Maximum Continuous Input Current 94 Adc Dry Contact Switch Voltage Rating 250 / 30 Vac / Vdc Dry Contao Switch Current Rating 5 A 2-wire Start Switch Yes AnnrrlhNl01 rFo nmr-r, I nstallation Type Suitable for use as service equipment For main Jug only Numberof Communication Inputs 2 Communication W ,.- _ RS485 Energy Meter (for Import/Export) 1% accuracy Manual Control Cher Microgrid Interconnection Device Yes il) Fach 40A CB supports up to one 7 fikW inverter, wlth each 53A C3 supporting one 1UW and one tl.dAW Inverter. The CB upgrade 0 s available with the f baling part nu m6ers: for 40A CB, CB-UJ G-dO-0'i; far 53A, CB CB-LJFG-G3-M. 20A 30A and SOA breakers can be uaed far Inverters with lower power ratings. R] Requires su pporting I nverter flrrrtware. SolarEdge Home Backup Interface For North America BI-EUSGN-02 / BI-NUSGN-02 STANDARD COMPLIANCE Safety INSTALLATION SPECI FI CATION S UL1741, CSA Suppo Eed Inverte s SSarEdge single: phase inverter, SolarEdge Home Hub Inverter AC Fram Grid Conduit Size /AWG Range 2" conduit o AWG —4/0 AC Inverter Conduit Size / AWG Range I" conduit /14 —4AWG AC Generator Input Conduit Size / AWG Rang_ e 1" conduit / B — 3 AWG Communication Card uit Size / AWG Range 3/4" / 24 —10 AWG Weight 73 / 33. Ib / Kg Cooling Fan (user replaceable) Noise s 50 dBA Operating Temperature Range -40 to +122 / -44 to +5d 'FIT Protection Rat-ng NEMA 3R IP44 Dimensions (HxWxp) X59 x 13.98 X 8 62 / 523.5 x 352 5 x219 in 1 mm Z+ SolarEdge Techmlogio; LtEL Al rghh asenled SOLAREDGE, the SolarEdge logo, OPTI M¢E BY SOLAREDGE aretrdtlemarksor regut—al t zde vwd of SolerEdgeTedirwNogre , Inc Al otI-trademarks mendem mentioned herd n are traabk ftheir-pectiveowners gate ALgut14,2022 DS-Q)W I -NAM. Suhjectto change withoutrvb . C Q FC