Loading...
HomeMy WebLinkAboutLIGHTING COMCHECK - 23-00170 - Rexburg 10 Ward LDS MeetinghouseCOMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Construction Site: 5th West and University Boulevard Rexburg, ID 83440 Owner/Agent:Designer/Contractor: Payne Engineering 1823 E Center St. Pocatello, ID 83201 208-232-4439 Project Information Energy Code: Rexburg ID Custom10 Ward Neetinghouse Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Religious Building 49103 0.85 41541 41541Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Religious Building LED 1: F1: 1X4 RECESSED FIXTURE: Other:1 117 40 4680 LED 2: F2: 2X4 SURFACE FIXTURE: Other:1 16 20 320 LED 3: F3: 2FT WALL MOUNTED VANITY FIXTURE: Other:1 7 63 441 LED 4: F4: 4FT WALL MOUNTED VANITY FIXTURE: Other:1 13 40 520 LED 5: F5: 4FT STRIP LIGHT: Other:1 42 30 1260 LED 6: F6: 4FT COVE STRIP: Other:1 48 34 1632 LED 7: F7: 4FT COVE STRIP: Other:1 20 25 500 LED 8: F8: FLEXIBLE COVE LIGHTING: Other:1 6 34 204 LED 9: F9: 2X4 RECESSED FIXTURE: Other:1 137 40 5480 LED 10: F10: 6" DOWN LIGHT: Other:1 89 25 2225 LED 11: F11: 8" DOWN LIGHT: Other:1 11 25 275 LED 12: F11b: 6" DOWNLIGHT: Other:1 16 25 400 LED 13: F12: 30" DIAMETER BOWL FIXTURE: Other:1 2 100 200 LED 14: F13: 36" DIAMETER BOWL FIXTURE: Other:1 12 100 1200 LED 15: F14: EXTERIOR WALL PACK: Other:1 5 60 300 LED 16: F15: SURFACE SPOT LAMP: Other:1 4 20 80 19717Total Proposed Watts = Project Title: Data filename: Rexburg ID Custom10 Ward Neetinghouse Untitled.cck 04/10/23Report date: 71 ofPage Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 53% better than code Project Title: Data filename: Rexburg ID Custom10 Ward Neetinghouse Untitled.cck 04/10/23Report date: 72 ofPage