HomeMy WebLinkAboutCOMCHECK - 23-00173 - Beehive Federal Credit UnionCOMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Title: 2018 IECC Project Type:New Construction Vertical Glazing / Wall Area:23% Location:Rexburg, Idaho Climate Zone:6b Construction Site: Corner of 2nd East & e Moody Road Rexburg, ID 83448 Owner/Agent: Craig Gummow Beehive Federal Credit Union 1087 Erikson Drive Rexburg, ID 83440 208-656-1000 Designer/Contractor: Geoff Nielson NBW Architects P.A. 990 John Adams Parkway Idaho Falls, ID 83401 208-522-8779 Project Information Energy Code: Beehive Federal Credit Union - N. Rexburg High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Additional Efficiency Package(s) Building Area Floor Area 1-Office : Nonresidential 2676 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter ROOF 13": Attic Roof with Wood Joists, [Bldg. Use 1 - Office]183 49.0 0.0 0.021 0.021 ROOF 14": Attic Roof with Wood Joists, [Bldg. Use 1 - Office]1878 49.0 0.0 0.021 0.021 ROOF 9.5: Attic Roof with Wood Joists, [Bldg. Use 1 - Office]652 57.0 0.0 0.018 0.021 SLAB FLOOR: Slab-On-Grade:Unheated, [Bldg. Use 1 - Office] (d)223 ------0.730 0.540 NORTH MASONRY WALL W: Wood-Framed, 16" o.c., [Bldg. Use 1 - Office]892 21.0 0.0 0.062 0.051 WINDOW SF W: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c) 64 ------0.290 0.360 DOOR SF W: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c) 24 ------0.290 0.770 EAST MASONRY WALL N: Wood-Framed, 16" o.c., [Bldg. Use 1 - Office]892 21.0 0.0 0.062 0.051 WINDOW SF N: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c) 66 ------0.290 0.360 SOUTH MASONRY COLUMN WALL E: Other Exterior Wall, Heat capacity 0.0, [Bldg. Use 1 - Office] (b) 40 ------0.820 0.051 MASONRY WALL E: Wood-Framed, 16" o.c., [Bldg. Use 1 - Office]595 21.0 0.0 0.062 0.051 WINDOW SF E: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c) 312 ------0.290 0.360 DOOR SF E: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf.97 ------0.290 0.770 Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 101 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Specs.: Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c) WEST MASONRY WALL S: Wood-Framed, 16" o.c., [Bldg. Use 1 - Office]892 21.0 0.0 0.062 0.051 WINDOW SF S: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c) 208 ------0.290 0.360 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 1% better than code Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 102 ofPage Cory Roberts - PM 04-05-2023 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.1.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2018 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable C402.4.1 [PR10]1 The vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable C402.4.1 [PR11]1 The skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 103 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable C402.2.4 [FO3]2 Slab edge insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.4 [FO7]2 Slab edge insulation depth/length. Slab insulation extending away from building is covered by pavement or >= 10 inches of soil. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 104 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.4 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 2.1 [FR19]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability <= 0.004 dfm/ft2. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable C402.5.2, C402.5.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable C402.5.7 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 105 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.5.5, C403.2.4. 3 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Refernece section C403.7.7 for operational details. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 106 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.6 [EL26]2 Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. Complies Does Not Not Observable Not Applicable C405.7 [EL27]2 Electric motors meet the minimum efficiency requirements of Tables C405.7(1) through C405.7(4). Efficiency verified through certification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). Complies Does Not Not Observable Not Applicable C405.8.2, C405.8.2. 1 [EL28]2 Escalators and moving walks comply with ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Complies Does Not Not Observable Not Applicable C405.9 [EL29]2 Total voltage drop across the combination of feeders and branch circuits <= 5%. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 107 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable C402.2.1 [IN20]1 Insulation installed on a suspended ceiling having ceiling tiles is not being specified for roor/ceiling assemblies. Continuous insulation board installed in 2 or more layers with edge joints offset between layers. Complies Does Not Not Observable Not Applicable C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable C402.2.3 [IN6]1 Above-grade wall insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.3 [IN8]2 Floor insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable C402.2.2 [IN2]1 Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 108 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable C402.5.8 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable C408.1.1 [FI57]1 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 109 ofPage Project Title: Data filename: Beehive Federal Credit Union - N. Rexburg N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU - N Rexburg ComCheck.cck 04/05/23Report date: 1010 ofPage