HomeMy WebLinkAboutCOMCHECK - 23-00173 - Beehive Federal Credit UnionCOMcheck Software Version 4.1.1.0
Envelope Compliance Certificate
Project Title:
2018 IECC
Project Type:New Construction
Vertical Glazing / Wall Area:23%
Location:Rexburg, Idaho
Climate Zone:6b
Construction Site:
Corner of 2nd East & e Moody Road
Rexburg, ID 83448
Owner/Agent:
Craig Gummow
Beehive Federal Credit Union
1087 Erikson Drive
Rexburg, ID 83440
208-656-1000
Designer/Contractor:
Geoff Nielson
NBW Architects P.A.
990 John Adams Parkway
Idaho Falls, ID 83401
208-522-8779
Project Information
Energy Code:
Beehive Federal Credit Union - N. Rexburg
High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist
report.
Additional Efficiency Package(s)
Building Area Floor Area
1-Office : Nonresidential 2676
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
ROOF 13": Attic Roof with Wood Joists, [Bldg. Use 1 - Office]183 49.0 0.0 0.021 0.021
ROOF 14": Attic Roof with Wood Joists, [Bldg. Use 1 - Office]1878 49.0 0.0 0.021 0.021
ROOF 9.5: Attic Roof with Wood Joists, [Bldg. Use 1 - Office]652 57.0 0.0 0.018 0.021
SLAB FLOOR: Slab-On-Grade:Unheated, [Bldg. Use 1 - Office] (d)223 ------0.730 0.540
NORTH
MASONRY WALL W: Wood-Framed, 16" o.c., [Bldg. Use 1 - Office]892 21.0 0.0 0.062 0.051
WINDOW SF W: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c)
64 ------0.290 0.360
DOOR SF W: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf.
Specs.: Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 -
Office] (c)
24 ------0.290 0.770
EAST
MASONRY WALL N: Wood-Framed, 16" o.c., [Bldg. Use 1 - Office]892 21.0 0.0 0.062 0.051
WINDOW SF N: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c)
66 ------0.290 0.360
SOUTH
MASONRY COLUMN WALL E: Other Exterior Wall, Heat capacity 0.0,
[Bldg. Use 1 - Office] (b)
40 ------0.820 0.051
MASONRY WALL E: Wood-Framed, 16" o.c., [Bldg. Use 1 - Office]595 21.0 0.0 0.062 0.051
WINDOW SF E: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c)
312 ------0.290 0.360
DOOR SF E: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf.97 ------0.290 0.770
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
101 ofPage
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Specs.: Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 -
Office] (c)
WEST
MASONRY WALL S: Wood-Framed, 16" o.c., [Bldg. Use 1 - Office]892 21.0 0.0 0.062 0.051
WINDOW SF S: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID SOLAR BAN 90, SHGC 0.23, [Bldg. Use 1 - Office] (c)
208 ------0.290 0.360
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)'Other' components require supporting documentation for proposed U-factors.
(c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2018 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Envelope PASSES: Design 1% better than code
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
102 ofPage
Cory Roberts - PM 04-05-2023
Inspection Checklist
Requirements: 0.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.1.1.0
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2018 IECC
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR1]1
Plans and/or specifications provide all
information with which compliance
can be determined for the building
envelope and document where
exceptions to the standard are
claimed.
Complies
Does Not
Not Observable
Not Applicable
C402.4.1
[PR10]1
The vertical fenestration area <= 30
percent of the gross above-grade wall
area.
Complies
Does Not
Not Observable
Not Applicable
C402.4.1
[PR11]1
The skylight area <= 3 percent of the
gross roof area.
Complies
Does Not
Not Observable
Not Applicable
C406
[PR9]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the additional energy
efficiency package options.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
103 ofPage
Section
#
& Req.ID
Footing / Foundation Inspection Complies?Comments/Assumptions
C303.2
[FO4]2
Slab edge insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[FO6]1
Exterior insulation protected against
damage, sunlight, moisture, wind,
landscaping and equipment
maintenance activities.
Complies
Does Not
Not Observable
Not Applicable
C402.2.4
[FO3]2
Slab edge insulation R-value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.4
[FO7]2
Slab edge insulation depth/length.
Slab insulation extending away from
building is covered by pavement or
>= 10 inches of soil.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[FO12]3
Radiant heating systems panels
insulated to >=R-3.5 on face opposite
space being heated.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
104 ofPage
Section
#
& Req.ID
Framing / Rough-In Inspection Complies?Comments/Assumptions
C303.1.3
[FR12]2
Fenestration products rated in
accordance with NFRC.
Complies
Does Not
Not Observable
Not Applicable
C303.1.3
[FR13]1
Fenestration products are certified as
to performance labels or certificates
provided.
Complies
Does Not
Not Observable
Not Applicable
C402.4.3
[FR10]1
Vertical fenestration SHGC value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.3,
C402.4.3.
4
[FR8]1
Vertical fenestration U-Factor.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.4
[FR14]2
U-factor of opaque doors associated
with the building thermal envelope
meets requirements.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.5.1.
2.1
[FR19]1
The building envelope contains a
continuous air barrier that is sealed in
an approved manner and material
permeability <= 0.004 dfm/ft2. Air
barrier penetrations are sealed in an
approved manner.
Complies
Does Not
Not Observable
Not Applicable
C402.5.2,
C402.5.4
[FR18]3
Factory-built fenestration and doors
are labeled as meeting air leakage
requirements.
Complies
Does Not
Not Observable
Not Applicable
C402.5.7
[FR17]3
Vestibules are installed on all building
entrances. Doors have self-closing
devices.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
105 ofPage
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies?Comments/Assumptions
C402.5.5,
C403.2.4.
3
[ME3]3
Stair and elevator shaft vents have
motorized dampers that automatically
close. Refernece section C403.7.7 for
operational details.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
106 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.6
[EL26]2
Low-voltage dry-type distribution
electric transformers meet the
minimum efficiency requirements of
Table C405.6.
Complies
Does Not
Not Observable
Not Applicable
C405.7
[EL27]2
Electric motors meet the minimum
efficiency requirements of Tables
C405.7(1) through C405.7(4).
Efficiency verified through certification
under an approved certification
program or the equipment efficiency
ratings shall be provided by motor
manufacturer (where certification
programs do not exist).
Complies
Does Not
Not Observable
Not Applicable
C405.8.2,
C405.8.2.
1
[EL28]2
Escalators and moving walks comply
with ASME A17.1/CSA B44 and have
automatic controls configured to
reduce speed to the minimum
permitted speed in accordance with
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
Complies
Does Not
Not Observable
Not Applicable
C405.9
[EL29]2
Total voltage drop across the
combination of feeders and branch
circuits <= 5%.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
107 ofPage
Section
#
& Req.ID
Insulation Inspection Complies?Comments/Assumptions
C303.1
[IN3]1
Roof insulation installed per
manufacturer’s instructions. Blown or
poured loose-fill insulation is installed
only where the roof slope is <=3 in
12.
Complies
Does Not
Not Observable
Not Applicable
C402.2.1
[IN20]1
Insulation installed on a suspended
ceiling having ceiling tiles is not being
specified for roor/ceiling assemblies.
Continuous insulation board installed
in 2 or more layers with edge joints
offset between layers.
Complies
Does Not
Not Observable
Not Applicable
C303.1
[IN10]2
Building envelope insulation is labeled
with R-value or insulation certificate
providing R-value and other relevant
data.
Complies
Does Not
Not Observable
Not Applicable
C303.2
[IN7]1
Above-grade wall insulation installed
per manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[IN14]2
Exterior insulation is protected from
damage with a protective material.
Verification for exposed foundation
insulation may need to occur during
Foundation Inspection.
Complies
Does Not
Not Observable
Not Applicable
C402.2.3
[IN6]1
Above-grade wall insulation R-value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.3
[IN8]2
Floor insulation R-value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[IN18]3
Radiant panels and associated
components, designed for heat
transfer from the panel surfaces to the
occupants or indoor space are
insulated with a minimum of R-3.5.
Complies
Does Not
Not Observable
Not Applicable
C402.2.2
[IN2]1
Roof R-value. For some ceiling
systems, verification may need to
occur during Framing Inspection.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.5.1.
1
[IN1]1
All sources of air leakage in the
building thermal envelope are sealed,
caulked, gasketed, weather stripped
or wrapped with moisture vapor-
permeable wrapping material to
minimize air leakage.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
108 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C402.5.6
[FI37]1
Weatherseals installed on all loading
dock cargo door openings and provide
direct contact along the top and sides
of vehicles parked in the doorway.
Complies
Does Not
Not Observable
Not Applicable
C402.5.6
[FI37]1
Weatherseals installed on all loading
dock cargo door openings and provide
direct contact along the top and sides
of vehicles parked in the doorway.
Complies
Does Not
Not Observable
Not Applicable
C402.5.6
[FI37]1
Weatherseals installed on all loading
dock cargo door openings and provide
direct contact along the top and sides
of vehicles parked in the doorway.
Complies
Does Not
Not Observable
Not Applicable
C402.5.6
[FI37]1
Weatherseals installed on all loading
dock cargo door openings and provide
direct contact along the top and sides
of vehicles parked in the doorway.
Complies
Does Not
Not Observable
Not Applicable
C402.5.8
[FI26]3
Recessed luminaires in thermal
envelope to limit infiltration and be IC
rated and labeled. Seal between
interior finish and luminaire housing.
Complies
Does Not
Not Observable
Not Applicable
C408.1.1
[FI57]1
Building operations and maintenance
documents will be provided to the
owner. Documents will cover
manufacturers' information,
specifications, programming
procedures and means of illustrating
to owner how building, equipment and
systems are intended to be installed,
maintained, and operated.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
109 ofPage
Project Title:
Data filename:
Beehive Federal Credit Union - N. Rexburg
N:\Projects\Other\Beehive North Rexburg Branch - New Bldg - 22021\45 Permitting\Beehive FCU -
N Rexburg ComCheck.cck
04/05/23Report date:
1010 ofPage