Loading...
HomeMy WebLinkAboutREDLINED FLOOR PLANS - 22-00007 - 253 W 2nd S - Sundance Bldg CAuthor Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2330 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : 253 W 2nd S - Sundance Bldg C Address : 253 W 2nd S Application Type : Document Filename : Bank Set 10-7-21 - No Renderings.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G1.1 Free text Cody Jones : Building Open 1 Occupancy classification R2. Construction type VA? Building height? Total area 52,571. Risk category as per table 1612.5. Need to identify ground and roof snow load, wind, seismic and other loads. Roof fire classification as per chapter 15. Need COMM check. Need structural, concrete and detail drawings with Engineer stamp. Building and plans to show ADA requirements, Special Inspector needs to be identified. Elevators to comply with Chapter 30. G1.1 Free text Cody Jones : Building Open 1 All Construction and materials to be in compliance with IBC 2018. # 22-00007 New Multi-Family Residence Report Date: 02.28.2022 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G1.1 Free text Cody Jones : Building Open 1 Automatic sprinkler to be installed. Shaft enclosures to meet requirements of Section 713. Penetrations to comply with section 714for rated assemblies. Fire partitions and fire walls to be in compliance with IBC 2018. Exit access and travel distance to be identified. G1.1 Free text Alex Owens : Electrical Open 1 All wiring methods must be in compliance with the 2017 NEC. AIC ratings needed for main breaker, bonding requirements needed (main water line if metal, structural steel if present, etc), verify required exit/emergency signs. Report Date: 02.28.2022 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) AREA MAP PROJECT SITE STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : SUNDANCE -BUILDING C MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel: (208) 232-4439 Fax: (208) 232-1435 OF DRAWING INDEX BYUI -APPROVED STUDENT HOUSING 10/5/2021 5:10:27 PM \\dc01\JRWA\Drawings\793 - Steven StudentHousing\07-BIM\793-Sundance Apartments - Building 3\793- Sundance Apartments - Building 3 - Update.rvt G1.1 CO V E R S H E E T 793 SU N D A N C E - B U I L D I N G C OCT 2021 JRN JRW OCT 2021 793 BY U I - A P P R O V E D S T U D E N T H O U S I N G Sheet Number Sheet Name Sheet Number Sheet Name G1.1 COVER SHEET SD1.1 PHASE TWO SITE PLAN - LAYOUT A1.1 BUILDING C - FIRST FLOOR PLAN A1.2 BUILDING C - SECOND FLOOR PLAN A1.3 BUILDING C - THIRD FLOOR PLAN A1.4 BUILDING C - FOURTH FLOOR PLAN A1.5 RENDERINGS general architectural SITE DEVELOPMENT REXBURG,IDAHO Occupancy classification R2. Construction type VA? Building height? Total area 52,571. Risk category as per table 1612.5. Need to identify ground and roof snow load, wind, seismic and other loads. Roof fire classification as per chapter 15. Need COMM check. Need structural, concrete and detail drawings with Engineer stamp. Building and plans to show ADA requirements, Special Inspector needs to be identified. Elevators to comply with Chapter 30. All Construction and materials to be in compliance with IBC 2018. Automatic sprinkler to be installed. Shaft enclosures to meet requirements of Section 713. Penetrations to comply with section 714for rated assemblies. Fire partitions and fire walls to be in compliance with IBC 2018. Exit access and travel distance to be identified. All wiring methods must be in compliance with the 2017 NEC. AIC ratings needed for main breaker, bonding requirements needed (main water line if metal, structural steel if present, etc), verify required exit/emergency signs. existing phase one parking 2nd south 3r d w e s t 11 11 11 10 19 14 10 10 6 23 23 STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E CT E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N ER S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S WI T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O H I B I TE D OF 10/5/2021 5:08:13 PM \\dc01\JRWA\Drawings\793 - Steven StudentHousing\07-BIM\793-Sundance Apartments - Building 3\793- Sundance Apartments - Building 3 - Update.rvt SD1.1 PH A S E T W O S I T E P L A N - L A Y O U T 793 SU N D A N C E - B U I L D I N G C OCT 2021 JRW JRW OCT 2021 BY U I - A P P R O V E D S T U D E N T H O U S I N G SCALE:1" = 20'-0" PHASE TWO SITE PLAN LAYOUT NORTH DW DW DW DW UP DW DW DW DW ENTRY B101 CLUB ROOM B102 WT3 WT3 WT7 WT7 WT3 WT3 WT3 HALL B111 A A B A A B A A E E E EEE ELEV. B105 EQUIP. B104 FIRE RISER B103 STAIR B107 PLUMB. CHASE B106 WT2 WT2 WT2 WT6 WT2 2 3 2 4 2 5 2 6 A A B AA B A A UNIT B3 TYPE B SEE A4.2 UNIT B5 TYPE B SEE A4.2 UNIT B4 TYPE B SEE A4.2 UNIT B2 TYPE B SEE A4.2 TYPICAL UNIT DOORS B1 = FRONT DOOR B2 = HALL STORAGE B3 = BATHROOM B4 = BEDROOM B5 = MECH. CLOSET B6 = HALL CLOSET B7 = HALL STOARGE (30"X84") B1 B4 B3 B5 B4 B4 B3 B3 B2 B103A B107A B104A D D WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1WT1 WT1 B101B B107B B101A B111A WT3 WT3 WT1 WT3 A ABA A B A A UNIT B5 TYPE B SEE A4.2 UNIT B4 TYPE B SEE A4.2 WT1 WT1 WT1 STAIR B112 H B112A UP WT1 B112B HALL B111 WT3 WT7 WT3 A B A A UNIT B5 TYPE B SEE A4.2 WT1 WT1 WT3 WT3 A B A A UNIT B5 TYPE B SEE A4.2 WT1 WT1 11' - 3 3/8"12' - 1 1/2"14' - 4"11' - 8"23' - 6 1/2"11' - 8"15' - 3"23' - 1"15' - 3"11' - 8"11' - 2 1/2" 23' - 10 7/8"6' - 5 1/2"11' - 2 1/2"26' - 11"23' - 4 3/4"14' - 11 1/4"11' - 8"23' - 1"11' - 8"26' - 11"11' - 3 3/8" 6' - 0 " 11' - 3 3/8" 21 ' - 5 1 / 2 " 12 ' - 1 1 / 4 " 12 ' - 0 1 / 4 " 11 ' - 8 " 53 ' - 7 " 11 ' - 8 " 11 ' - 8 " 161' - 0 7/8" 13 4 ' - 2 " 2' - 0 " 24 ' - 7 3 / 4 " 25 ' - 5 3 / 8 " 18 ' - 0 1 / 4 " 14 ' - 4 1 / 8 " 191' - 5 1/4" 43' - 7 3/4" 22' - 2 1/4"21' - 5 1/2" 50 ' - 9 " 57 ' - 9 3 / 4 " total area: 13,336 s.f. NOTES: SEE DETAILS A/G1.5 AND B/G1.5 FOR GRAB BARS MIRRORS AND TYPICAL MOUNTING HTS. SIGN TYPE -SEE DOOR SCHEDULE, SEE DETAIL A/G1.5 FOR MOUNTING HEIGHTS AND LOCATIONS FOR SIGNS LOCATED AT DOOR. 1 2 X STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E CT E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N ER S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S WI T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O H I B I TE D OF 10/7/2021 8:33:36 AM C:\Users\JNowland.JRWA\Documents\793- Sundance Apartments -Building 3 - Update\jnowland.rvt A1.1 BU I L D I N G C - F I R S T F L O O R P L A N 793 SU N D A N C E - B U I L D I N G C OCT 2021 JRN JRW OCT 2021 BY U I - A P P R O V E D S T U D E N T H O U S I N G SCALE:1/8" = 1'-0" BUILDING C - FIRST FLOOR PLAN NORTH DW DW DW DW DNUP DW DW UP DN DW DW A A B A A B A J A AAABA A A B open to below open to below open to below F F F FFF H H ELEV. B202 STAIR B204 PLUMB. CHASE B203 2 TYP. WT2 WT2 WT2 WT6 WT2 WT2 WT2 1 3 1 4 READING NOOK B201 TYPICAL UNIT DOORS A1 = FRONT DOOR A2 = HALL STORAGE A3 = BATHROOM A4 = BEDROOM A5 = MECH. CLOSET A6 = HALL CLOSET A7 = HALL STOARGE (30"X84") B206A HALL B205 MECH. B206 UNIT 12 TYPE B SEE A4.2 UNIT B10 TYPE B SEE A4.2 UNIT B9 TYPE B SEE A4.2 UNIT B11 TYPE B SEE A4.2 B204A WT1 WT1 WT1 WT1 WT1WT1 WT1 WT1 WT1 WT1 A ABA A B A A UNIT 12 TYPE B SEE A4.2 UNIT B11 TYPE B SEE A4.2 WT1 WT1WT1 H STAIR B206 B206A WT1 HALL B205 A B A A UNIT 12 TYPE B SEE A4.2 WT1 A B A A UNIT 12 TYPE B SEE A4.2 WT1 total area: 12,711 s.f. NOTES: SIGN TYPE -SEE DOOR SCHEDULE, SEE DETAIL A/G1.5 FOR MOUNTING HEIGHTS AND LOCATIONS FOR SIGNS LOCATED AT DOOR. CANOPY ROOF SEE DETAIL XXX 1 X 2 STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E CT E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N ER S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S WI T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O H I B I TE D OF 10/7/2021 8:33:41 AM C:\Users\JNowland.JRWA\Documents\793- Sundance Apartments -Building 3 - Update\jnowland.rvt A1.2 BU I L D I N G C - S E C O N D F L O O R P L A N 793 SU N D A N C E - B U I L D I N G C OCT 2021 JRN JRW OCT 2021 BY U I - A P P R O V E D S T U D E N T H O U S I N G SCALE:1/8" = 1'-0" BUILDING C - SECOND FLOOR PLAN NORTH DW DW DW DW UP DN DW DW UP DN DW DW A G G G GGG H H STOR. B303 FIRE RISER B302 PLUMB. CHASE B305 ELEV. B304 STAIR B306 WT2 WT2 WT2 WT2 WT2 1 3 1 4 15 UNIT B18 TYPE B SEE A4.2 UNIT B16 TYPE B SEE A4.2 UNIT B17 TYPE B SEE A4.2 UNIT B19 TYPE B SEE A4.2 STUDY ROOM B301 MECH. B308 A A B A A B A A J A A B AA B A A B308A WT7 WT7 WT3 WT3 WT3 WT3 WT2 WT2 WT2 WT6 WT2 WT2 TYPICAL UNIT DOORS A1 = FRONT DOOR A2 = HALL STORAGE A3 = BATHROOM A4 = BEDROOM A5 = MECH. CLOSET A6 = HALL CLOSET A7 = HALL STOARGE (30"X84") B306A B302A B301A WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 B303A UNIT B18 TYPE B SEE A4.2 UNIT B19 TYPE B SEE A4.2 A A B A A B A A WT1 WT1 WT1 WT1 STAIR B308 see drawing a3.1 for large scale plan 1 H B308A WT1 UNIT B19 TYPE B SEE A4.2 A B A A WT7 WT1 UNIT B19 TYPE B SEE A4.2 A B A A WT7 WT1 total area: 13,355 s.f. NOTES: SIGN TYPE -SEE DOOR SCHEDULE, SEE DETAIL A/G1.5 FOR MOUNTING HEIGHTS AND LOCATIONS FOR SIGNS LOCATED AT DOOR. 1 X STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E CT E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N ER S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S WI T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O H I B I TE D OF 10/7/2021 8:33:44 AM C:\Users\JNowland.JRWA\Documents\793- Sundance Apartments -Building 3 - Update\jnowland.rvt A1.3 BU I L D I N G C - T H I R D F L O O R P L A N 793 SU N D A N C E - B U I L D I N G C OCT 2021 JRN JRW OCT 2021 BY U I - A P P R O V E D S T U D E N T H O U S I N G SCALE:1/8" = 1'-0" BUILDING C - THIRD FLOOR PLAN NORTH DW REF. DW DW DW DN DW DW DN DW DW H G G G G G G A LOUNGE/ FAMILY ROOM B401 FIRE RISER B402 STOR. B403 ELEV. B404 PLUMB. CHASE B405 STAIR B407 1 3 1 4 15 H B407A B409A B406A B402A A A B A A B A A K WT2 WT2 WT2 WT6 WT3 WT3 WT3 WT3 WT3 WT3 WT7 WT7 WT6 WT2 STOR. B406 HALL B408 MECH. B409 TYPICAL UNIT DOORS A1 = FRONT DOOR A2 = HALL STORAGE A3 = BATHROOM A4 = BEDROOM A5 = MECH. CLOSET A6 = HALL CLOSET A7 = HALL STOARGE (30"X84") A A B A A B A A UNIT B24 TYPE B SEE A4.2 UNIT B26 TYPE B SEE A4.2 UNIT B25 TYPE B SEE A4.2 UNIT B23 TYPE B SEE A4.2 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 WT1 B403A A ABA WT3 WT3 WT1 WT1 A ABA UNIT B26 TYPE B SEE A4.2 UNIT B25 TYPE B SEE A4.2 WT1 WT1 WT1 see drawing a3.1 for large scale plan 1 B409AH STAIR B409 WT1 WT1 WT1 HALL B408 A A B A WT3 WT7 UNIT B26 TYPE B SEE A4.2 WT1 WT1 A A B A WT3 WT7 UNIT B26 TYPE B SEE A4.2 WT1 WT1 total area: 13,349 s.f. NOTES: SIGN TYPE -SEE DOOR SCHEDULE, SEE DETAIL A/G1.5 FOR MOUNTING HEIGHTS AND LOCATIONS FOR SIGNS LOCATED AT DOOR. 1 X STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E CT E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N ER S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S WI T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O H I B I TE D OF 10/7/2021 8:33:48 AM C:\Users\JNowland.JRWA\Documents\793- Sundance Apartments -Building 3 - Update\jnowland.rvt A1.4 BU I L D I N G C - F O U R T H F L O O R P L A N 793 SU N D A N C E - B U I L D I N G C OCT 2021 JRN JRW OCT 2021 BY U I - A P P R O V E D S T U D E N T H O U S I N G SCALE:1/8" = 1'-0" BUILDING C - FOURTH FLOOR PLAN NORTH