Loading...
HomeMy WebLinkAboutAPPROVED PLANS 1/20/2023 - 23-00054 - Maverik Store #505 - RemodelAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Maverik Store #505 - Remodel Address : 859 W Main St Record Type : Commercial - Remodel Document Filename : #505 Rexburg, ID - Permit Set - 230120_.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00054 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G0.01 Stamp Cody Jones : Building Open 1 Approved - Building Inspector G0.01 Free Text Cody Jones : Building Open 1 All construction and materials to comply with IBC 2018. G0.01 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector E0.01 Stamp Alex Owens : Electrical Open 28 Approved - Electrical Inspector E0.01 Free Text Alex Owens : Electrical Open 28 All electrical work to comply with 2017 NEC E3.03 Callout Alex Owens : Electrical Open 31 Ensure receptacle is located so it will service all rooftop equipment or add receptacle for equipment farther away. G0.01 Stamp Don Allen : Mechanical Open 1 Approved - Plumbing Inspector G0.01 Stamp Don Allen : Mechanical Open 1 Approved - Mechanical Inspector G0.01 Stamp Kyle Baldwin : P&Z Open 1 Approved - Planning and Zoning Commercial - Remodel Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) OWNER MAVERIK, INC 185 SOUTH STATE STREET #800 SALT LAKE CITY, UT 84111 PHONE 801.936.5557 ARCHITECT, STRUCTURAL/MECHANICAL/ELECTRICAL ENGINEER GPD GROUP, PROFESSIONAL CORPORATION 520 SOUTH MAIN STREET #2531 AKRON, OH 44311 CONTACT: ALISSA COBB EMAIL: acobb@gpdgroup.com PHONE: 678-781-5069 CITY MAP STREET MAP APPLICABLE CODE: 2018 INTERNATIONAL BUILDING CODE. (I.B.C.) 2018 INTERNATIONAL MECHANICAL CODE 2017 IDAHO PLUMBING CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL FUEL AND GAS CODE 2017 NATIONAL ELECTRIC CODE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN OCCUPANCY CLASSIFICATION: M DESCRIPTION: GAS STATION/CONVENIENCE STORE CONSTRUCTION TYPE: V-B BUILDING HEIGHT: 28' - 7" RETAIL AREA: 2,774 S.F. BUILDING AREA: 3,987 S.F. FIRE SPRINKLERS: NOT REQUIRED (PER IBC 2018 SECTION 903.2.7) FIRE RESISTANCE RATINGS OF EXTERIOR WALLS TABLE 601 AND 602 - NON-RATED OCCUPANT LOAD: 41 OCCUPANTS MERCANTILE: 2,146 S.F. @ 1 OCC. PER 60 S.F. = 36 OCCUPANTS KITCHEN : 579 S.F. @ 1 OCC. PER 200 S.F. = 3 OCCUPANTS STORAGE: 264 S.F. @ 1 OCC. PER 300 S.F. = 1 OCCUPANTS OFFICES: 85 S.F. @ 1 OCC. PER 100 S.F. = 1 OCCUPANTS EGRESS WIDTH REQUIRED: 41 OCC. @ .2" PER OCC. = 8.2" EGRESS WIDTH PROVIDED: 9' - 0" (1) 6'-0" (3'-0" PAIR) SLIDING DOORS AT STOREFRONT (W/ BREAKAWAY) (1) 36" EXIT DOOR NEAR RESTROOMS. PLUMBING FIXTURES REQUIRED: PLUMBING FIXTURES PROVIDED: (1) MEN'S TOILET (2) MEN'S TOILET, (2) URINAL (1) WOMEN'S TOILET (3) WOMEN'S TOILET (1) MEN'S SINK (1) MEN'S SINK (1) WOMEN'S SINK (1) WOMEN'S SINK (1) DRINKING FOUNTAIN DRINKING FOUNTAIN: NOT REQUIRED (PER IPC 2018 SECTION 410.4) (1) SERVICE SINK (1) SERVICE SINK TILE EMSER TILE RENEE ANDERSON (801) 573-6772 MAVERIK@EMSER.COM & RENEEANDERSON@EMSER.COM ACCOUNT #: 1380974 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 1 1 : 1 5 : 1 8 A M COVER SHEET 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL G0.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 MAVERIK, INC. 859 WEST MAIN STREET REXBURG, ID 83440 TYPE B REMODEL MAVERIK C-STORE #505 N VICINITY MAPS DRAWING INDEX PROJECT DIRECTORYCODE SUMMARY NATIONAL ACCOUNTS GENERAL G0.01 COVER SHEET G0.02 GENERAL INFORMATION ARCHITECTURAL AD.01 DEMOLITION FLOOR PLAN AD.02 DEMOLITION REFLECTED CEILING PLAN A1.01 DIMENSION FLOOR PLAN A1.02 REFERENCE AND FINISH FLOOR PLAN A1.03 EQUIPMENT FLOOR PLAN A1.04 EQUIPMENT SCHEDULE A1.05 REFLECTED CEILING PLAN A2.51 INTERIOR ELEVATIONS & WALL TYPES A4.02 ENLARGED RETAIL PLANS & ELEVATIONS A4.03 ENLARGED RETAIL PLANS & ELEVATIONS A5.11 DETAILS A6.03 FINISH & MATERIAL SCHEDULES STRUCTURAL S0.01 GEN. STRUCTURAL NOTES S0.02 GEN. STRUCTURAL NOTES S1.11 ROOF FRAMING PLAN S5.10 FOUNDATION & FRAMING DETAILS PLUMBING P0.00 PLUMBING LEGENDS & NOTES P0.01 PLUMBING DEMOLITION PLAN P1.01 PLUMBING WASTE AND VENT PLAN P1.02 PLUMBING WATER PLAN P2.00 PLUMBING SCHEDULES P2.01 PLUMBING DETAILS P2.02 PLUMBING ISOMETRICS GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 MECHANICAL M0.01 MECHANICAL LEGENDS & NOTES M1.01 MECHANICAL FLOOR PLAN ELECTRICAL E0.01 ELECTRICAL NOTES & SCHEDULES E3.00 ELECTRICAL POWER PLAN E3.02 ELECTRICAL LIGHTING PLAN E3.03 ELECTRICAL ROOF PLAN E6.00 ELECTRICAL SCHEDULES E6.01 PANEL SCHEDULES 01/20/23 All construction and materials to comply with IBC 2018. 4 1 2 3 A252 CLOUD INDICATES DRAWING REVISION AREA ROOM NAME ROOM NUMBER SHEET NUMBER SECTION NUMBER ELEVATION NUMBER REVISION NUMBER ELEVATION NUMBER SHEET WHERE DRAWN SHEET NUMBER DETAIL NUMBER SHEET NUMBER 00.00 BUILDING SECTION WALL SECTION EXTERIOR ELEVATION INTERIOR ELEVATION PARTITION TYPE A-222 A2 NUM ROOM NAME 101 A KEYED NOTE GLAZING TYPE DOOR TAG A1 A-101 A1 A-101 SHEET NUMBER SECTION NUMBER SHEET NUMBER DETAIL NUMBER DETAIL SECTION DETAIL ROOM TAG REVISION TAG A1 A-101 SHADE INDICATES ELEVATED WALL 1 A-222 A2 A 1i DIVISION NUMBER KEYNOTE NUMBER GYPSUM BOARD OR CONCRETE SURFACE HATCH PATTERN BELOW INDICATES REPRESENTATION OF BUILDING MATERIALS IN BUILDING SECTIONS, WALL SECTIONS AND DETAILS. CONCRETE STUD WALL GRAVEL COMPACTED FILL AND/OR EARTH CMU (CONCRETE MASONRY UNIT) BATT INSULATION RIGID INSULATION PAPER TOWEL DISPENSER SOAP DISPENSER FIRE EXTINGUISHER CABINET HIGHEST OPERABLE PARTS SANITARY NAPKIN DISPENSER TOILET PARTITION URINAL PARTITION 1 2 " 4 8 " 1 2 " 5 8 " U .N .O . BABY CHANGING STATION HAND DRYER MIRROR WITH FRAME MOP RACK S U R F A C E 3 '-4 " M A X T O R E F L E C T I V E 6 0 " M A X . 4 8 " FLOOR LINE ACCESSIBLE WATER CLOSET FLOOR LINE ACCESSIBLE LAVATORY MIN. 15" 9 " M I N 6" MAX (TOE CLEAR.)(KNEE CLEAR.) 8" MIN (TOE CLEAR. DEPTH) 17" - 25" 2 '-3 " M I N WALL NOTE: EXPOSED PIPE SHALL BE INSULATED (NO SHARP OR ABRASIVE SURFACES BELOW LAVATORY) T O R E F L E C T I V E S U R F A C E 4 0 " M A X 3 4 " M A X SANITARY NAPKIN DISPOSAL 2 " FACE OF WALL FACE OF WALL 2" 1 7 "-1 9 " 7"-9" GRAB BAR 16" - 18" 3 3 " - 3 6 " M I N 1 8 " 3 3 " - 3 6 " 4 4 " M A X 1 7 "-1 9 " 12" MIN. MAX. 1' - 0"42" MIN 24" MIN. 3 9 " - 4 1 " 39" - 41" 3 4 " M A X . 11" MIN. 54" MIN 1 5 " M I N FLOOR LINE FUEL CANOPY ACCESSORIES FUEL CANOPY COLUMN 4 ' - 0 " SIGNAGE TO COMPLY WITH IFC 2305.6 AND POSTED ON EACH SIDE OF COLUMN M I N 6 " 1' - 5" S.S.I. MOUNTED TO COLUMN PER ADA REQUIREMENTS (4'-0" MAX A.F.F. TO PAPER TOWEL FOLD FUEL PUMP ACCESSIBLE URINAL 4 8 " M A X @ H .C . 1 7 " M A X . COAT HOOK 4 6 " WHERE SINGLE DOOR OCCURS, MOUNT SIGNS ALONG THE LATCH SIDE. REFER TO CHAPTER 7 OF 2010 ADA STANDARDS FOR ADDITIONAL REQUIREMENTS. WHERE OPENING WITH NO DOOR OCCURS, MOUNT SIGNS, WHERE SHOWN ON SHEET A1.02 REFERENCE AND FINISH FLOOR PLAN 9" MIN. WOMEN NAME RESTROOM SIGN ACCORDING TO THE CORRESPONDING ROOM TAG LOCATED ON SHEET A1.02 6 " M I N . 4 8 " M I N . LOCATION OF GENDER PICTOGRAM BRAILLE PER 2010 ADA STANDARDS SECTION 703.3, NAME ACCORDING TO CORRESPONDING ROOM TAGS ON SHEET A1.02 5 / 8 " - 2 " PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 4 0 P M GENERAL INFORMATION 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL G0.02 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 GENERAL NOTES ABBREVIATIONSMATERIAL LEGEND SYMBOLS LEGEND 1. GENERAL: BASIC CONTRACT DEFINITIONS ARE INCLUDED IN THE CONDITIONS OF THE CONTRACT. 2. "APPROVED": WHEN USED TO CONVEY ARCHITECT'S ACTION ON CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, "APPROVED" IS LIMITED TO ARCHITECT'S DUTIES AND RESPONSIBILITIES AS STATED IN THE CONDITIONS OF THE CONTRACT. 3. "DIRECTED": A COMMAND OR INSTRUCTION BY ARCHITECT. OTHER TERMS INCLUDING "REQUESTED," "AUTHORIZED," "SELECTED," "REQUIRED," AND "PERMITTED" HAVE THE SAME MEANING AS "DIRECTED." 4. "INDICATED": REQUIREMENTS EXPRESSED BY GRAPHIC REPRESENTATIONS OR IN WRITTEN FORM ON DRAWINGS, IN SPECIFICATIONS, AND IN OTHER CONTRACT DOCUMENTS. OTHER TERMS INCLUDING "SHOWN," "NOTED," "SCHEDULED," AND "SPECIFIED" HAVE THE SAME MEANING AS "INDICATED." 5. "REGULATIONS": LAWS, ORDINANCES, STATUTES, AND LAWFUL ORDERS ISSUED BY AUTHORITIES HAVING JURISDICTION, AND RULES, CONVENTIONS, AND AGREEMENTS WITHIN THE CONSTRUCTION INDUSTRY THAT CONTROL PERFORMANCE OF THE WORK. 6. "FURNISH": SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. 7. "INSTALL": UNLOAD, TEMPORARILY STORE, UNPACK, ASSEMBLE, ERECT, PLACE, ANCHOR, APPLY, WORK TO DIMENSION, FINISH, CURE, PROTECT, CLEAN, AND SIMILAR OPERATIONS AT PROJECT SITE. 8. "PROVIDE": FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. 9. "PROJECT SITE": SPACE AVAILABLE FOR PERFORMING CONSTRUCTION ACTIVITIES. THE EXTENT OF PROJECT SITE IS SHOWN ON DRAWINGS AND MAY OR MAY NOT BE IDENTICAL WITH THE DESCRIPTION OF THE LAND ON WHICH PROJECT IS TO BE BUILT. DEFINITIONS TYPICAL MOUNTING HEIGHTS ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISH FLOOR B.O. BOTTOM OF CMU CONCRETE MASONRY UNIT CONC. CONCRETE CONT. CONTINUOUS D.O.T. DEPARTMENT OF TRANSPORTATION DIA DIAMETER EIFS EXTERIOR INSULATED FINISH SYSTEM EQ EQUAL FRP FIBERGLASS REINFORCED PANEL G.C. GENERAL CONTRACTOR IBC INTERNATIONAL BUILDING CODE MAX MAXIMUM MIN MINIMUM NIC NOT IN CONTRACT O.C. ON CENTER P.O.S. POINT OF SALE SIM SIMILAR SPEC SPECIFICATION SS STAINLESS STEEL T.O. TOP OF TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE W/ WITH 1. ALL INTERIOR WALLS TO WRAPPED WITH 5/8" GYPSUM WALL BOARD, TAPED, FILLED, AND FINISHED AS PER ROOM FINISH SCHEDULE AND OWNER. 2. ALL PRODUCTS ON THIS PROJECT SHALL BE INSTALLED PER MANUFACTURER'S REQUIREMENTS AND SPECIFICATIONS. ACCESSIBLE SIGNAGE GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 G G 22 F F 2.12.1 2.52.5 02.08 02.11 02.78 113 ELECTRICAL ROOM 112 STORAGE 105 DELI PREP 101 RETAIL 110 30° BEER COOLER 109 OFFICE 106 KITCHEN SERVICE 107 35° STOR. COOLER 108 -10° FREEZER 02.11 02.11 02.82 104 EXIT HALLWAY B B C C E E D D A A 3 3 11 115 35° BEVERAGE COOLER 02.08 02.05 02.08 NO WORK IN THIS AREA 02.81 3' - 6"2' - 0"11' - 4" 2 ' - 0 " 2 ' - 0 " 7 ' - 5 " 5 ' - 0 " 2 1 ' - 0 " 9' - 9 1/4" 2 ' - 3 " 02.85 02.78 02.12 02.86 02.06 F.V. 2' - 0" 02.1102.1102.11 02.07 02.01 02.01 02.01 02.09 02.80 02.10 02.10 02.0702.0702.0702.07 02.73 02.08 02.09 02.0802.08 2' - 0" 114 STORAGE 02.02 02.78 10' - 0" TYP. 02.29 02.09 02.08 02.03 02.03 02.03 02.82 02.09 F .V . 1 0 ' - 0 " 02.12 02.12 02.12 102 WOMEN'S 103 MEN'S 02.01 6 ' - 8 3 /8 " 8' - 6 1/8"4' - 0" 02.16 GENERAL NOTES 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION. 2. CONTRACTOR TO PROTECT ALL ITEMS TO REMAIN FROM DAMAGE. 3. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION. 4. AT WALL TRANSITION FROM NEW TO EXISTING WALLS PATCH, REPAIR AND/OR REPLACE GYP. BOARD AS REQUIRED TO PROVIDE FLUSH TRANSITION BETWEEN NEW AND EXISTING SURFACES. 5. PATCH / REPAIR / PREP WALLS AS NECESSARY TO RECEIVE NEW PAINT AT LOCATIONS WHERE EQUIPMENT WAS REMOVED. 6. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.N.O. 7. CONTRACTOR TO CONFIRM CONDITION AND NEED FOR REPLACEMENT OF EXISTING TOILETS / URINALS WITH MAVERIK CONSTRUCTION MANAGER. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 3 7 P M DEMOLITION FLOOR PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL AD.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 02.01 SAW CUT AROUND EXISTING FLOOR SINK AND REMOVE EXISTING FLOOR SINK AND CAP BELOW SLAB. FIELD VERIFY EXTENTS AND PATCH WITH CONCRETE. SEE STRUCTURAL DRAWINGS FOR PATCHING REQUIREMENTS 02.02 SAW CUT AROUND EXISTING POWER/DATA CONDUIT AND REMOVE EXISTING POWER AND DATA AND CAP BELOW SLAB. FIELD VERIFY EXTENTS AND PATCH WITH CONCRETE. SEE STRUCTURAL DRAWINGS FOR PATCHING REQUIREMENTS 02.03 REMOVE GONDOLA. COORDINATE REMOVAL WITH OWNER 02.05 REMOVE COUNTERTOP AND CABINETS. COORDINATE POWER AND DATA REMOVAL WITH NEW CASH WRAP REQUIREMENTS 02.06 REMOVE CASH WRAP RAISED PLATFORM 02.07 REMOVE WALL IN ITS ENTIRETY. WHERE REMOVED WALL INTERSECTS EXISTING WALL TO REMAIN, PATCH REMAINING WALL TO MATCH ADJACENT WALL. RELOCATE ANY EXISTING PLUMBING/ELECTRICAL AS REQUIRED FOR NEW LAYOUT 02.08 REMOVE EQUIPMENT. SEE PLUMBING & ELECTRICAL DRAWINGS FOR ADDITIONAL DEMO SCOPE. COORDINATE REMOVAL WITH OWNER KEYED NOTESSCALE:1/4" = 1'-0"1 DEMOLITION FLOOR PLAN N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 02.78 HATCHED AREA INDICATES APPROXIMATE CONCRETE SLAB TO BE SAW CUT AND REMOVED FOR NEW UTILITIES. CONTRACTOR TO FIELD VERIFY TYPE OF SLAB CONSTRUCTION PRIOR TO BEGINNING ANY DEMOLITION. REFER TO STRUCTURAL DETAIL 10/S5.10. FIELD VERIFY EXTENTS AND COORDINATE WITH PLUMBING DRAWINGS. SEE STRUCTURAL DRAWINGS FOR SLAB PATCHING REQUIREMENTS. 02.80 REMOVE EXISTING ROOF TOP ICEMAKER CONDENSER. PATCH AND REPAIR ROOF AS REQUIRED TO ENSURE WATER TIGHT 02.81 REMOVE EXISTING COUNTER. BASE MILLWORK TO REMAIN. PREP FOR NEW COUNTERTOP 02.82 NO WORK IN THIS AREA 02.85 HATCHED AREA INDICATES APPROXIMATE CONCRETE SLAB TO BE SAW CUT AND REMOVED FOR NEW POWER FROM EXISTING J-BOX IN WALL TO NEW MILLWORK. GC TO FIELD VERIFY LOCATION OF J-BOX AND COORDINATE LOCATION OF TRENCHING. CONTRACTOR TO VERIFY TYPE OF SLAB CONSTRUCTION PRIOR TO BEGINNING ANY DEMOLITION. SEE STRUCTURAL DRAWINGS FOR SLAB PATCHING REQUIREMENTS. 02.09 REMOVE MILLWORK IN ITS ENTIRETY AS WELL AS ALL EQUIPMENT/FIXTURES ATOP OR INSIDE MILLWORK. COORDINATE EQUIPMENT REMOVAL WITH OWNER. COORDINATE ELECTRICAL AND PLUMBING REMOVAL WITH NEW EQUIPMENT REQUIREMENTS 02.10 REMOVE PLUMBING FIXTURE. COORDINATE DRAIN AND WATER REMOVAL WITH NEW PLUMBING LOCATION(S) 02.11 EXISTING WALL TO REMAIN; PROTECT DURING CONSTRUCTION 02.12 REMOVE WALL GRAPHICS IN RETAIL AREA, BEER COOLER, RESTROOMS AND EXIT HALL; PREP WALLS FOR NEW GRAPHICS 02.16 PREP FLOOR FOR NEW TILE INSTALLATION 02.29 REMOVE SHELVING FROM COOLER; COORDINATE WITH OWNER 02.73 EXISTING HOOD TO REMAIN 02.86 REMOVE EXISTING FLOORING AND ADHESIVES TO SLAB. PREP FOR NEW TILE INSTALLATION 01/20/23 G G 22 F F 2.12.1 2.52.5 TYP. 02.43 02.77 103 MEN'S 102 WOMEN'S 113 ELECTRICAL ROOM 112 STORAGE 105 DELI PREP 101 RETAIL 110 30° BEER COOLER 109 OFFICE 106 KITCHEN SERVICE 107 35° STOR. COOLER 108 -10° FREEZER 02.83 104 EXIT HALLWAY B B C C E E D D A A 3 3 11 02.83 02.8302.47 02.47 02.83 114 STORAGE 02.83 02.83 02.83 02.83 115 35° BEVERAGE COOLER 02.83 TYP. 02.44 TYP. 02.44 TYP. 02.44 02.12002.120 02.120 TYP. 02.43 TYP. 02.44 TYP. 02.44 02.73 2 ' - 7 " 1 ' - 4 3 /4 " 2' - 0 1/4" TYP. 02.4302.43 02.88 TYP. 02.43 TYP. 02.43 02.43 10.48 10.48 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 3 8 P M DEMOLITION REFLECTED CEILING PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL AD.02 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 DEMOLITION REFLECTED CEILING PLAN 02.43 EXISTING LIGHT FIXTURE TO REMAIN; PROTECT DURING CONSTRUCTION 02.44 REMOVE LIGHT FIXTURE 02.47 EXISTING CEILING TO REMAIN 02.73 EXISTING HOOD TO REMAIN 02.77 HATCHED AREA INDICATES ACOUSTIC CEILING TILE AND GRID TO BE REPLACED 02.83 NO CEILING WORK IN THIS AREA 02.88 REMOVE EXISTING CEILING MOUNTED KAYAKS AND SNOW BOARDS COMPLETELY. EXISTING TREES TO REMAIN. PROTECT DURING DEMO AND CONSTRUCTION. 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS, MATERIALS, FINISHES, AND DIMENSIONS BEFORE AND AFTER DEMOLITION. 2. CONTRACTOR TO PROTECT ALL ITEMS TO REMAIN FROM DAMAGE. 3. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION. 4. AT WALL TRANSITION FROM NEW TO EXISTING WALLS PATCH, REPAIR AND/OR REPLACE GYP. BOARD AS REQUIRED TO PROVIDE FLUSH TRANSITION BETWEEN NEW AND EXISTING SURFACES. 5. PATCH / REPAIR / PREP WALLS AS NECESSARY TO RECEIVE NEW PAINT AT LOCATIONS WHERE EQUIPMENT WAS REMOVED. 6. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.N.O. 7. CONTRACTOR TO CONFIRM CONDITION AND NEED FOR REPLACEMENT OF EXISTING TOILETS / URINALS WITH MAVERIK CONSTRUCTION MANAGER. N KEYED NOTES GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 02.120 REMOVE EXISTING CAN LIGHTS. PREP TO RECEIVE NEW PER A1.05. 10.48 EXISTING MONITOR TO REMAIN. PROTECT DURING CONSTRUCTION GENERAL NOTES 01/20/23 G G 22 F F 2.12.1 2.52.5 5' - 0 " 19 ' - 0 " 2' - 0 " 3' - 6"2' - 0" 03.14 102 WOMEN'S 113 ELECTRICAL ROOM 112 STORAGE 105 DELI PREP 101 RETAIL 110 30° BEER COOLER 109 OFFICE 106 KITCHEN SERVICE 108 -10° FREEZER ALIGN B B C C E E D D A A 3 3 11 107 35° STOR. COOLER 114 STORAGE V.I.F. 2' - 0" CLEAR 11' - 2" 4' - 2" 03.14 9' - 9 1/4" 2' - 3 " 115 35° BEVERAGE COOLER 14' - 10"2' - 0" 2' - 0 " 7' - 5 " 2' - 0 " 05.63 E3 D6 2' - 9" 7' - 2 1 / 2 " 3' - 0 " 6' - 1 7 / 8 " E3 D3 D3 D3 19' - 9"10' - 2 3/8" 03.14 4' - 0" 6' - 8 3 / 8 " 05.72 C3 V .I .F . 1 0 ' - 0 " 104 EXIT HALLWAY 103 MEN'S 10' - 0" 05.63 05.63 03.14 2' - 10 1/8" PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 2 4 P M DIMENSION FLOOR PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A1.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 PROPOSED FLOOR PLAN GENERAL NOTESKEYED NOTES 03.14 HATCHED AREA INDICATES NEW CONCRETE TO MATCH EXISTING, SEE DETAILS 8, 9 AND 10/S5.10 ON STRUCTURAL DRAWINGS. PROVIDE NEW TILE TO MATCH EXISTING. SEE AD.01 FOR DIMENSIONS. 05.63 PROVIDE STAINLESS STEEL SINK SURROUND IN CABINET AT FLOOR SINK LOCATION, SEE DETAIL 4/A5.11. SEE PLUMBING PLANS FOR FLOOR SINK LOCATIONS 05.72 INFILL WALL WHERE DOOR HAS BEEN REMOVED. MATCH EXISTING WALL STRUCTURE AND FINISH GENERAL NOTES 1. ALL PENETRATIONS IN CABINETRY TO BE CAULKED AND SEALED. 2. CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE CONCRETE FLOOR AND GLASS DURING CONSTRUCTION. 3. SEE EQUIPMENT PLAN - SHEET A1.03, WALL TYPES AND PLAN ON SHEETS A1.01, A5.01. 4. ALL GRID LINES ARE INDICATED AT EDGE OF STUD. 5. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.N.O. 6. ALL DIMENSIONS TO NEW WALLS ARE TO FACE OF STUD, U.N.O. 7. SEE SHEET A6.03 FOR FINISH SCHEDULE. 8. PROVIDE CRACK-SUPPRESSION MEMBRANE AT ALL TILE LOCATIONS. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 9. ALL CORNER GUARDS TO BE MOUNTED ON THE FINISHED FLOORING. CONT. CAULK BETWEEN THE GUARD AND FLOORING AND THE GUARD AND THE RUBBER BASE. 10. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT IF VARIATIONS IN EXISTING CONDITIONS OCCUR. 11. CONTRACTOR TO VERIFY ALL CABINETRY COLORS WITH MAVERIK PROJECT MANAGER. 12. CONTRACTOR TO VERIFY REUSE OR REPLACEMENT OF RESTROOM FIXTURES WITH MAVERIK PROJECT MANAGER WHEN RESTROOMS ARE RECONFIGURED. 01/20/23 G G 22 A2.51 A2.51 2 1 F F 2.12.1 2.52.5 3B 103 MEN'S EXIST 102 WOMEN'S EXIST 104 EXIT HALLWAY EXIST 112 STORAGE CT-4 113 ELECTRICAL ROOM 105 DELI PREP EXIST 107 35° STOR. COOLER 108 -10° FREEZER 106 KITCHEN SERVICE EXIST 109 OFFICE EXIST 110 30° BEER COOLER CT-4 A4.02 1 A4.02 6 A4.02 10 A4.03 1 A4.03 10 A4.03 6 A4.03 15 ABOVE ABOVE ABOVE ABOVE ABOVE A4.03 9 10.51 06.07 06.07 09.05 A4.02 16 B B C C E E D D A A 3 3 11 09.73 10.51 10.51 114 STORAGE EXIST 10.19 10.19 10.5210.5210.52 10.52 10.19 115 35° BEVERAGE COOLER 101 RETAIL EXIST 10.1910.19 10.19 06.07 06.07 5 ' - 0 " 4' - 10"13' - 4" 4 ' - 6 " 4' - 10" 4 ' - 6 " 4' - 10" 07.31 06.07 09.73 06.07 10.2410.24 10.24 06.07 10.22 11' - 4" 3 ' - 6 " 5 ' - 6 1 /4 " 10.51 A4.02 8 07.31 09.05 07.31 06.07 7' - 6" 1 9' - 0" 3 0 ° 3 0 ° PREP WALL FOR LEVEL 4 FINISH FOR PRESSURE SENSITIVE WALL GRAPHICS, PAINTED P-7. PROVIDE CLEAR BRA PROTECTIVE COATING OVER GRAPHIC UP TO 30" IN EXIT HALLWAY ONLY FRP LOCATIONS WALL TILE LOCATIONS CORNER GUARD LOCATIONS PREP WALL FOR LEVEL 3 FINISH FOR SUEDE WALL GRAPHICS, PAINTED P-7 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 2 6 P M REFERENCE AND FINISH FLOOR PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A1.02 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 REFERENCE FLOOR PLAN GENERAL NOTESKEYED NOTES 06.07 CASEWORK PROVIDED AND INSTALLED BY OWNER'S VENDOR 07.31 CONFIRM THRESHOLD AND WEATHERSTRIPPING CONDITION AT FRONT DOOR AND BEER COOLER ENTRY DOOR WITH MAVERIK CONSTRUCTION MANAGER AND REPLACE IF NECESSARY 09.05 SLOPED TRANSITION STRIP. SCHLUTER-RENO-RAMP OR EQUAL 09.73 PAINT DOOR AND FRAME BLACK FOX, SW #7020. ALL RETAIL FACING DOORS PAINT FRAME ONLY 10.19 CORNER GUARD, TO UNDERSIDE OF SOFFIT. INSTALL CORNER GUARDS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD GENERAL NOTES 1. ALL PENETRATIONS IN CABINETRY TO BE CAULKED AND SEALED. 2. CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE CONCRETE FLOOR AND GLASS DURING CONSTRUCTION. 3. SEE EQUIPMENT PLAN - SHEET A1.03, WALL TYPES AND PLAN ON SHEETS A1.01, A5.01. 4. ALL GRID LINES ARE INDICATED AT EDGE OF STUD. 5. ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.N.O. 6. ALL DIMENSIONS TO NEW WALLS ARE TO FACE OF STUD, U.N.O. 7. SEE SHEET A6.03 FOR FINISH SCHEDULE. 8. PROVIDE CRACK-SUPPRESSION MEMBRANE AT ALL TILE LOCATIONS. SYMBOL LEGEND N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 9. ALL CORNER GUARDS TO BE MOUNTED ON THE FINISHED FLOORING. CONT. CAULK BETWEEN THE GUARD AND FLOORING AND THE GUARD AND THE RUBBER BASE. 10. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT IF VARIATIONS IN EXISTING CONDITIONS OCCUR. 11. CONTRACTOR TO VERIFY ALL CABINETRY COLORS WITH MAVERIK PROJECT MANAGER. 12. CONTRACTOR TO VERIFY REUSE OR REPLACEMENT OF RESTROOM FIXTURES WITH MAVERIK PROJECT MANAGER WHEN RESTROOMS ARE RECONFIGURED. 10.22 CORNER GUARD, TO 7'-6" A.F.F. INSTALL CORNER BEADS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD 10.24 CORNER GUARD, TO TOP OF TILE OR FRP, INSTALL CORNER BEADS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD 10.51 CORNER GUARD, TO 10'-0" A.F.F. INSTALL CORNER BEADS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD 10.52 CORNER GUARD, TO BOTTOM OF WALL CAP 01/20/23 G G 22 103 MEN'S 109 OFFICE 104 EXIT HALLWAY 102 WOMEN'S 112 STORAGE 105 DELI PREP 106 KITCHEN SERVICE 107 35° STOR. COOLER 108 -10° FREEZER F F 2.12.1 2.52.5 33 33C 113 ELECTRICAL ROOM N109 22 N33 N33 94 N104 (x2) 10.59 10.59 101 101 B B C C E E D D A A 3 3 11 115 35° BEVERAGE COOLER 111 114 STORAGE 2460 2436 2430 2460 2436 2436 2436 2436 2436 2436 2436 (x11)N31 V.I.F. 9' - 4" V .I .F . 3 0 ' - 9 1 /2 " 110 30° BEER COOLER 10.5909.35 101 RETAIL 48 N110 N110 8 8 15 N49 13 14 16 N106 N69 N71 N69 9593 51 N63A 2118 4 3 ' - 0 " 3 ' - 0 " 1 ' - 1 " 4 ' - 0 " 4 ' - 0 " 4 ' - 0 " 1 ' - 1 " 2 ' - 6 " 4 ' - 0 " 4 ' - 0 " 4 ' - 0 " 1 ' - 6 " 2 ' - 0 " 3 ' - 6 " 3 ' - 6 " 1 ' - 1 " 3 ' - 0 " 11.05 11.05 11.05 42 N69 4242 42 N69 N69N69 23N67 N67 N67 N67 3 ' - 0 " CLEAR MIN. 11' - 2" 46 10.15 10.60 N33 10.5910.63 N1115151 N63A P6 22 102 109 N95 N95 10.66 11.21 20A 09.35 115 115 6 1' - 6" 4 ' - 0 " 11115 69 73 737474 N71 19 8 51 N63A 10 SCALE:1/4" = 1'-0"1 EQUIPMENT FLOOR PLAN 09.35 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 14/A4.02 AND SEE SCHEDULE ON SHEET A6.03 10.15 SS PASS THROUGH OPENING FOR SYRUP LINES. FIT BETWEEN STUDS 10.59 PROVIDE BLOCKING IN WALL AS REQUIRED 10.60 GC TO PROVIDE A STAINLESS COVER OVER ABANDONED CONDUIT 10.63 INSTALL WALL MOUNTED TRAX SYSTEM DIRECTLY OVER 3-COMPARTMENT SINK 10.66 GC TO CONFIRM THAT CO2 TANK IS BANDED AND SECURED 11.05 OWNER PROVIDED EQUIPMENT 11.21 GC TO CONFIRM CO2 DETECTOR LOCATION. IF MISSING, PROVIDE AND INSTALL AS REQUIRED. KEYED NOTES GENERAL NOTES 1. REFER TO SHEET A1.04 FOR EQUIPMENT SCHEDULE 2. SEE MECHANICAL FOR ROOF MOUNTED EQUIPMENT. REFER TO DETAIL 13/A5.11 FOR CURB DETAIL. 3. GC TO VERIFY ALL EQUIPMENT TO FIT AS COORDINATED. ANY DISCREPENCIES TO BE BROUGHT UP WITH MAVERIK CONSTRUCTION MANAGER. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 2 7 P M EQUIPMENT FLOOR PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A1.03 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 EQUIPMENT SCHEDULE IT E M C o u n t DESCRIPTION LOCATION MODEL/MFG.DIMENSIONS SU P P L I E D IN S T A L L E D NOTES: ELECTRICAL PLUMBING NOTE:NOTES: 4 1 ICE/BEVERAGE DISPENSER DRINK WALL FLAVOR SELECT/ FS60 O V 6 1 DONUT CASE COFFEE AREA O GC 8 3 FRESH FOODS CASE HOT DOG COUNTER O GC 10 1 DISPLAY WARMER COFFEE/DRINK ISLAND FRI-JADO MD48-3-SB 47.25"x31.5"x56 7/8" O GC 11 1 CAPPUCCINO MACHINE COFFEE COUNTER Bunn iMix-5S 19.3"x23.9"x34.36" O GC 13 1 CONDIMENT DROP-IN HOT DOG COUNTER RANDELL-9943SCA 43-3/8" x 26" x 27-1/2" O GC INTERNAL CONDENSER AND COMPRESSOR NEMA 5-15-PLUG REQUIRES VENTS; SEE DRAWINGS GC TO PROVIDE CUTOUT; SEE DWGS 14 1 MICROWAVE OVEN HOT DOG COUNTER SANASONIC-NE-1024 20-1/8" x 16-9/16" x 12" O GC NEMA .5-15 PORORNEMA .5-2 OR NEMA 5-15 PLUG 15 1 HOT DOG ROLLER GRILL HOT DOG COUNTER SILVERSTONE-8075S 35-1/2" x 25-3/4" x 7" O GC 16 1 NACHO MACHINE HOT DOG COUNTER GEHL DUO 18" x 17" x 35" O GC 18 1 QUIETQUBE ICE MAKER KITCHEN SERVICE HOSHIZAKI 30" x 24" x 32-7/8" O GC SITS ABOVE #4 ON SOFFIT ABOVE CONNECTED TO #18A-REMOTE CONDENSER 19 1 FOG TANK KITCHEN SERVICE FOG TANK - MINI 28.5" x 16" x 33" 20A 1 OVEN/RACK COFFEE PREP NU-VU-OP-4/8M 30" X 35-1/2" X 78-1/4" O GC 21 1 ICE MAKER ( OVER BEV. DISP.)DRINK WALL N13 22R-32 SCOTSMAN PRODIGY PLUS O GC SITS ABOVE #4 (ON SOFFIT ABOVE0 CONNECTED TO #18A-REMOTE CONDENSER 22 2 FOOD PREP UNIT DELI PREP RANDELL O GC 23 1 SMART SAFE CASH WRAP SENTINAL SCD-XL & TUBE 24.25" x 24" x 40" O V NO CONNECTIONS BEHIND ONLY MOUNT CONNECTIONS TO SIDE OF UNIT (NOT BEHIND) 33 1 ICE CREAM MERCHANDISER RETAIL ZERO ZONE O GC REMOTE CONDENSER ON ROOF #33A 33C 1 ICE MAKER ( OVER BEV. DISP.)DRINK WALL N13 22R-32 SCOTSMAN PRODIGY PLUS O GC SITS ABOVE #4 (ON SOFFIT ABOVE0 CONNECTED TO #18A-REMOTE CONDENSER ALWAYS ON CUSTOMERS LEFT 42 4 POS ARRAY PER PLAN O O 46 1 CIGARETTE CASE CASH WRAP VENDOR O GC 48 1 CREAMER DISPENSER COFFEE COUNTER CREAMISER MODEL400 21"x16"x29"O V 51 4 STAINLESS STEEL SINK (HAND OR BAR)PER PLAN FURNISHED BY MILLWORK GC GC SEE PLUMBING DRAWINGS 69 1 CUBELET ICE MACHINE AND WATER DISPENSER COFFEE PREP HOSHIZAKI DCM-271BAH-0S 16.6"x24.25"x31.75" O GC 73 2 FROZEN CARBONATED BEV.DRINK WALL ICEE-VIPER 3 FLAV.20.3" x 32.5" x 41.4" O GC INTERNAL CONDENSER 74 2 FROZEN UNCARBONATED BEV.DRINK WALL BUNN ULTRA-2 16"x32"x26.2" O GC 93 1 F'REAL-MINI BLENDING BAR DRINK WALL 11-CSGF-X1-FRRL 33.5"x32.5"x56" O GC/O 94 1 STEAM WARMER DELI PREP AREA O GC 95 1 F'REAL DRINK WALL O GC/O 101 2 VECTOR MULTI-COOK OVEN DELI PREP VECTOR H SERIES VMC-H4 43.6"x21.5"x37.5" O GC 102 1 PIZZA WARMERS DELI PREP CHOICE FOOD PIZZA STACK SHELF-R3 70"x20.5"x24" O GC 109 1 TORTILLA TABLE DELI PREP O GC 111 1 TORTILLA TOASTER DELI PREP AREA O GC 115 3 BEAN TO CUP COFFEE MACHINE COFFEE/DRINK ISLAND ART C TOUCH 3G/SCHAERER 17"x22"x35.5" O GC N31 11 WIRE SHELVING ISS (VARIOUS SIZES, SHAPES) O GC N33 4 OVERHEAD WIRE SHELF WITH BRACKET COFFEE PREP/BOH SERVICE SPG/ISS WALL TRAX/SPG 8'-0" BRACKET O GC CONFIRM WITH OWNER'S REP. N49 1 SNEEZE GUARD HOT DOG COUNTER MAVERIK CUSTOM O GC PLACED ABOVE EQUIPMENT NUMBER 13 OR 13.2 N63A 3 PAPER TOWEL DISPENSER RESTROOMS CORMATIC AUTO TOWEL DISP. 14.25" x 9.1" x 15.5" O GC N67 4 UNDER COUNTER BAG RACK CASH WRAP COUNTER OWNER CUSTOM O GC N68 1 LIDS FOR FCB MACHINE(*12)DRINK WALL ICEE CUSTOM V V N69 6 UNDERCOUNTER CANDY RACKS SHOP CO 2" x 12" x 2"O GC N71 2 STAINLESS STEEL TRASH CHUTE HOT DOG COUNTER OWNER CUSTOM GC GC N95 2 SNEEZE GUARD DELI SERVICES GC GC N101 1 4' TABLE ISS (VARIOUS SIZES, SHAPES) O GC CONFIRM WITH OWNER'S REP. N104 1 4' SS TABLE W/ CABINET BASE COFFEE PREP ISS (VARIOUS SIZES, SHAPES) O GC CONFIRM WITH OWNER'S REP. N106 1 CONDIMENT RACK HOT DOG COUNTER N109 1 LABLE MAKER DELI PREP DO NOT WALL MOUNT N110 2 FLAVOR SHOT RACK COFFEE COUNTER N111 1 WALL TRAX DELI SERVICES SPG/ISS WALL TRAX GRID 8'-0" X 3'-0"O GC CONFIRM WITH OWNER'S REP. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 2 8 P M EQUIPMENT SCHEDULE 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A1.04 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 G G 22 109 OFFICE 104 EXIT HALLWAY 102 WOMEN'S 105 DELI PREP 106 KITCHEN SERVICE 110 30° BEER COOLER 101 RETAIL 112 STORAGE 108 -10° FREEZER 107 35° STOR. COOLER F F 2.12.1 2.52.5 113 ELECTRICAL ROOM 12 A5.11 BELOW 02.83 B B C C E E D D A A 3 3 11 TYP. 26.04 10.45 10.45 26.04 9 ' - 6 " 09.47 10.6410.64 10.64 115 35° BEVERAGE COOLER 10.54 02.83 ACT-1 05.02 3' - 0"10' - 3" 09.01 09.61 09.7209.72 114 STORAGE TYP. 26.04 02.83 02.83 02.83 103 MEN'S 09.59 09.36 P-7 09.77 09.36 09.77 P-7 P-7 09.36 09.60 02.83 09.77 2x4 LAY-IN LIGHT FIXTURE; SEE ELECTRICAL 2x4 FIXTURE, EMERGENCY LIGHT; SEE ELECTRICAL LINEAR LIGHT FIXTURE, SEE ELECTRICAL RECESSED LIGHT FIXTURE WALL SCONCE: SEE ELECTRICAL 4'-0" SURFACE MOUNTED LIGHT FIXTURE COOLER VAPOR PROOF LIGHT; SEE ELECTRICAL SCHEDULE EXIT LIGHTING SUPPLY AND RETURN AIR VENTS SKYLIGHT; SEE ROOF PLAN 4'-0" SURFACE MOUNTED EMERGENCY LIGHT FIXTURE 4'-0" SURFACE MOUNTED LIGHT FIXTURE SCALE:1/4" = 1'-0"1 REFLECTED CEILING PLAN 02.83 NO CEILING WORK IN THIS AREA 05.02 METAL SOFFIT PANEL, COLOR C-2 BRITE RED. PROVIDE STRAPPING AS REQUIRED 09.01 SCHEDULED CEILING, INSTALL SUSPENDED CEILING BRACING SEE DETAIL 6/A5.11 09.36 PAINT EXISTING CEILING. SEE SCHEDULE ON SHEET A6.03 09.47 HEADER, PAINT P-7, SEE SCHEDULE ON SHEET A6.03 09.59 PAINT EXISTING OPEN CEILING (STRUCTURE, DECK, DUCTWORK). SEE SCHEDULE ON SHEET A6.03 09.60 REPAINT ANY AND ALL LIGHTS THAT HAVE PREVIOUSLY BEEN PAINTED TO MATCH CEILING. SEE SCHEDULE ON SHEET A6.03 FOR NEW PAINT COLOR 09.61 SEE DETAIL 5/A5.11 FOR SUSPENDED CEILING TILE AT WALL 09.72 PAINT EXISITING AND NEW CEILING GRID AND TILES IN VISIBLE AREAS AT DELI PREP. SEE SCHEDULE ON SHEET A6.03. 09.77 PATCH AND REPAIR CEILING AS REQUIRED. KEYED NOTES SYMBOLS (EXISTING, U.N.O.)PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 2 9 P M REFLECTED CEILING PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A1.05 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10.45 43" MENU MONITORS, (BY OWNER) AND CEILING MOUNTED BRACKET; SEE DETAILS 8 & 9 ON SHEET A5.11 10.54 MONITOR, (BY OWNER) IN FOUNTAIN MACHINE 10.64 INSTALL NEW CAN LIGHT FIXTURES. 26.04 NEW LIGHT FIXTURE, SEE ELECTRICAL PLANS 01/20/23 B O H T I L E 6 ' - 8 " V .I .F . T O B .O . A C T 4 ' - 4 " B .O . D E C K 1 7 ' - 2 " V .I .F . TRASH 09.35 10.1110.11 09.13 TYP. 11.10 09.20 4 4 1 /2 " 10.4510.45 09.58 05.67 06.07 TRASH 09.2009.2006.0709.16 10.5410.1110.11 05.67 09.1309.58 09.1309.58 10.46 10.5210.52 10.19 10.15 PLAN VIEW 8 3 8 WALL TYPE STUD SIZE 3 5/8" 5/ 8 " 5/ 8 " D3 WALL WIDTH 4 7/8" St u d Si z e 1 5 TYP 2 SECTION VIEW T Y P 6 " M I N . WALL WIDTH VARIES WITH STUD SIZE 3 9 88 Type - D Typical Metal Stud Wall 5 10 WALL TYPE STUD SIZE WALL WIDTH E3 3 5/8" 4 7/8" 16 SECTION VIEW PLAN VIEW 6 178 14 6 17 18 13 12 1 1/2" 1 1/2"3" 3/16" 8 8 9" 13 14 Type - E Partial Height Wall WALL WIDTH VARIES WITH STUD SIZE 3/ 4 " F O R W A L L H E I G H T S E E I N T E R I O R E L E V A T I O N S 10 3 /4 " 2 " 3 /4 " 4 4 3 D6 6"7 1/4" PLAN VIEW 3 8 WALL TYPE STUD SIZE 3 5/8" 5/ 8 " C3 WALL WIDTH 4 1/4" 1 5 TYP 2 SECTION VIEW T Y P 6 " M I N . WALL WIDTH VARIES WITH STUD SIZE 3 9 8 Type - C Typical Metal Stud Wall 5 4 4 DOUBLE METAL FRAMING HEAD VARIES 1/2" 2" 5 / 8 " R. O . PT. HARDWOOD SHIM AT PIN ASSEMBLY ATTACHMENT POINTS AS REQUIRED STUD TRACK HEAVY GAUGE TRACK (18 GAUGE MINIMUM) DOOR FRAME DOUBLE STUD ALL DOOR JAMBS (CONTINUE TO AND FASTEN TO JOIST OR UNISTRUT ABOVE VARIES COUNTER SUNK FLAT HEAD SCREWS 1/2" 2" 5 / 8 " R. O . PT. HARDWOOD SHIM AT PIN ASSEMBLY ATTACHMENT POINTS AS REQUIRED R. O . FIN. FLOOR DOOR FRAME BEYOND FIXED FLOOR ANCHOR IN JAMB BEYOND EXISTING TILE FLOORINGCONCRETE SLAB 2"3' - 0"2" 2 " 7 ' - 0 " A 1 A S S C H E D U L E D AS SCHEDULED F I E L D V E R I F Y 7 ' - 2 " 02.84 09.1309.13 SCALE:1/4" = 1'-0"1 RETAIL ELEVATION - RIGHT SCALE:1/4" = 1'-0"2 RETAIL ELEVATION - BACK WALL TYPE KEYED NOTES 02.84 EXISTING WALL TILE TO REMAIN 05.67 STEEL AWNING, PAINTED TO MATCH BRITE RED, SEE DETAIL 12 ON SHEET A5.11 AND SCHEDULE ON SHEET A6.03 06.07 CASEWORK PROVIDED AND INSTALLED BY OWNER'S VENDOR 09.13 GYPSUM WALL BOARD WITH LEVEL 3 FINISH FOR SUEDE WALL GRAPHICS, PAINTED P-1 09.16 PLASTIC LAMINATE CABINET, SEE SCHEDULE ON SHEET A6.03 09.20 RUBBER BASE, SEE SCHEDULE ON SHEET A6.03 09.35 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 14/A4.02 AND SEE SCHEDULE ON SHEET A6.03 09.58 HATCHED WALL INDICATES NEW WALL TO RECEIVE NEW PAINT / GRAPHICS AS INDICATED 10.11 SS CORNER GUARD, SEE SHEET A1.02 FOR LOCATIONS 10.15 SS PASS THROUGH OPENING FOR SYRUP LINES. FIT BETWEEN STUDS 10.19 CORNER GUARD, TO UNDERSIDE OF SOFFIT. INSTALL CORNER GUARDS OVER WALL MATERIAL. STOP RUBBER WALL BASE AT CORNER GUARD 10.45 43" MENU MONITORS, (BY OWNER) AND CEILING MOUNTED BRACKET; SEE DETAILS 8 & 9 ON SHEET A5.11 10.46 75" MONITOR, (PROVIDED BY OWNER) AND CEILING MOUNTED BRACKET; SEE DETAILS 10 & 11 ON SHEET A5.11 10.52 CORNER GUARD, TO BOTTOM OF WALL CAP 10.54 MONITOR, (BY OWNER) IN FOUNTAIN MACHINE 11.10 SNEEZE GUARD, PROVIDED AND INSTALLED BY MILLWORK VENDOR PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 3 1 P M INTERIOR ELEVATIONS & WALL TYPES 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A2.51 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 1. LINE OF ROOF DECK AS OCCURS. 2. TO ACCOMMODATE FOR STRUCTURE DEFLECTION, PROVIDE SLIP CONNECTION BETWEEN TOP RUNNER TRACK AND METAL STUD FRAMING. 3. METAL STUDS, 20 GA STRUCTURAL (33 MILS) AT 16" O.C, U.N.O. BASED ON WALL TYPES INDICATED IN FLOOR PLAN, PROVIDE STUD SIZE AS INDICATED IN WALL TYPES WITH TRACK RUNNERS AT TOP AND BOTTOM. FOR STUD FRAMING AROUND DOOR AND WINDOW OPENINGS. 4. EXTEND GYPSUM BOARD TO ROOF DECK IN PUBLIC AREAS WHERE THERE IS NO CEILING. CUT GYPSUM BOARD TO FILL FLUTES OF ROOF DECK, WHERE APPLICABLE. 5. LINE OF CEILING AS OCCURS SEE REFLECTED CEILING PLAN. 6. 3/8" THICK STEEL PLATE WITH 4-1/2" DIA. HILTI-HY200 EPOXY ANCHORS WITH 2-3/8" HILTI-HIT -Z ANCHORS. EMBED INTO CONCRETE 2-3/8" 7. NOT USED. 8. GYPSUM BOARD, 5/8" THICK, U.N.O, ATTACHED TO METAL STUD FRAMING. SEE GENERAL NOTE 'B'. 9. ANCHOR BASE TRACK TO CONCRETE FLOOR BELOW. 10. LINE OF FLOOR. 11. NOT USED. 12. METAL STUDS 16GA STRUCTURAL (35 MIL) AT 16" O.C. PROVIDE RUNNERS AT TOP AND BOTTOM. ATTACH TOP RUNNER TO PLYWOOD AND VERTICAL STEEL POST. 13. PROVIDE 1/4" RADIUS ROUNDED EDGE, CONTINOUS. 14. STOP STUD RUNNER AT BASE PLATES. 15. NOT USED. 16. WALL CAP. SOLID SURFACE MATERIAL ATTACHED TO WALL BELOW. 17. TUBE STEEL 3" x 3" x 3/16" AT 6'- 0" O.C. 18. PLYWOOD BLOCKING. INTERIOR ELEVATIONS KEYED NOTES GENERAL NOTES A. CONTRACTOR SHALL VERIFY ITEMS LIKE SEMI OR FULLY RECESSED MISCELLANEOUS BOXES, PANELS, PLUMBING LINES, CONDUITS, PIPES, ETC. THAT ARE CONCEALED IN THE WALL. IF 3-5/8" METAL STUD ARE INADEQUATE, CONTRACTOR SHALL NOTIFY THAT ARCHITECT AND USE 6" STUDS. COORDINATE WITH ALL THE CONSULTANT DRAWINGS PRIOR TO WALL CONSTRUCTION AND USE 6" OR 8", 20 GAUGE METAL STUDS FOR FRAMING IN LIEU OF 3-5/8" METAL STUDS. B. USE 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD IF CERAMIC OR PORCELAIN WALL TILES ARE INDICATED IN THE FINISH SCHEDULES AS WALL FINISH. MOISTURE RESISTANT GYPSUM WALL BOARD SHALL EXTEND FROM FINISHED FLOOR TO HEIGHT OF TILE. 5/8" WATER RESISTANT GYPSUM BOARD TO BE USED ABOVE TILE HEIGHT IN RESTROOMS. C. PROVIDE CONTROL JOINT WHEN LENGTH OF GYPSUM BOARD EXCEEDS 50' IN ONE DIRECTION OR AS DIRECTED BY ARCHITECT. COORDINATE WITH ARCHITECT FOR CONTROL JOINT LOCATIONS. WHEN GYPSUM BOARD IS ATTACHED VERTICALLY, USE 1" LONG #6 DRYWALL SCREWS TO EACH STUD. SCREWS ARE 8" O.C. AT PERIMETER AND 12" AT INTERMEDIATE STUD. WHEN GYPSUM BOARD IS ATTACHED HORIZONTALLY TO STUDS, HORIZONTAL JOINTS SHALL BE STAGGERED WITH THOSE ON THE OPPOSITE SIDE. SCREWS FOR HORIZONTAL APPLICATION SHALL BE 8" O.C. AT VERTICAL EDGES AND 12" O.C. AT INTERMEDIATE STUDS. D. SEE DIMENSION FLOOR PLAN FOR WALL TYPES USED IN THIS PROJECT. GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 DOOR SCHEDULE MARK LOCATION DOORS FRAME HARDWARE SET COMMENTS DOOR TYPE WIDTH HEIGHT DEPTH MATERIAL FINISH MANUFACTURER MODEL FRAME TYPE MATERIAL HEAD JAMB SILL 1 KITCHEN SERVICE A 3' - 4" 7' - 0" 1 3/4" STEEL STAINLESS RUBBAIR DOOR ULTRA- LITE-SS BY RUBBAIR WELDED HOLLOW METAL 4/A2.51 5/A2.51 6/A2.51 BY MANUF PROVIDE SPRING GUARD, VISION PANE, AND RUBBAIR DOOR STOP 3A SCALE:1 1/2" = 1'-0"4 DOOR HEAD SCALE:1 1/2" = 1'-0"5 DOOR JAMB SCALE:1 1/2" = 1'-0"6 DOOR SILL ALL EXISTING CONDITIONS INCLUDING THE STRUCTURAL SUPPORT NEEDS TO BE FIELD VERIFIED. ANY DISCREPANCIES NEEDS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT SCALE:1/4" = 1'-0" DOOR TYPE AND FRAME SCALE:1/4" = 1'-0"3B TYP. RESTROOM WALL TILE DETAIL 01/20/23 2 " 1/2"1/2" 1 /2 " 1 " 1 /2 " 3/4" 09.35 06.24 09.16 09.44 1 3 /4 " 1 " 1 /2 " 09.35 06.24 09.441/2" A4.02A4.02 A4.02 2 35 A4.02 4 14 A4.02 2 ' - 3 3 /8 " 3 ' - 6 7 /8 "5 ' - 1 0 1 /4 " 2' - 10 1/8"1' - 11 1/4"8' - 7"1' - 11 1/4"2' - 7 1/2" 17' - 11 1/8" 1 ' - 0 " 1 ' - 1 1 1 /4 " 11.09 3' - 6 7/8"10' - 10 1/2"3' - 5 3/4" TYP. 11.05 09.48 1 ' - 1 1 1 /4 " 1 ' - 4 1 /2 " 3 ' - 5 3 /4 " 4 ' - 1 0 1 /4 " 26.09 CASH DRAWER CASH DRAWERCASH DRAWERCASH DRAWER TYP. 11.11 11.0909.48 09.16 09.20 2 ' - 1 0 " 2' - 7 1/2"ANGLED2' - 1 1/2"1' - 0 7/8"2' - 2 3/4"1' - 0 7/8"2' - 1 1/2"ANGLED2' - 7 1/4" 17' - 8 5/8" 6 " 2 ' - 2 1 /2 " 1 1 /2 " 2 ' - 1 0 " ANGLED1' - 1 3/4" 4' - 6 3/8" 11.05 09.48 09.16 09.20 1 1 /2 " 2 ' - 2 1 /2 " 6 " 2' - 1 1/2"ANGLED 5' - 7 3/8" 1 1 /2 " 2 ' - 2 1 /2 " 6 " 2 ' - 1 0 " 11.05 09.48 09.16 09.20 2 ' - 1 0 " ANGLED6"4' - 1 1/2"1' - 7"4' - 1 1/2"6"ANGLED 17' - 8 5/8" 09.48 09.16 09.20 11.0511.0511.0511.05 1 1 /2 " 2 ' - 2 1 /2 " 6 " A4.02 7 TYP. 3 ' - 0 " 09.35 11.0511.0511.05 10.47 15 A4.02 11.05 11.0511.0511.05 TRASH 4 " 2 " 2 ' - 2 1 /2 " 5 1 /2 " 6 " 2 ' - 1 0 " 1' - 8"1' - 8"1' - 8"1' - 11"1' - 8"1' - 8"1' - 8"1' - 8"1' - 9 1/2"1' - 9 1/2"1' - 10"2" 19' - 4" 09.35 09.16 TYP. 09.22 09.20 A4.02 11 A4.0212 6 ' - 2 7 /8 " 2 ' - 1 0 1 /2 " 7 ' - 3 " 2' - 11" 3 ' - 0 " TRASH 7' - 3"2' - 11"6' - 2" 3 ' - 7 " 09.3509.35 09.16 2 ' - 8 1 /2 "1 1 /2 " 2 ' - 1 0 " 09.2009.20 09.24 09.37 09.35 TYP. 11.10 09.3509.3509.35 TYP. 11.10 09.1609.20 3 ' - 6 " 11' - 8" 2' - 9"2' - 9"2' - 9" 2 ' - 6 " 2' - 6" 4' - 0" 09.35 09.35 3' - 6" 2 ' - 2 " 10.47 A4.02 9 4 " 1 1 /2 " 2 ' - 3 " 5 1 /2 " 6 " 2 ' - 1 0 " 2 3/4" 2' - 10 1/2" 2 3/4" 3' - 4" 09.63 09.16 09.20 KEYED NOTES 06.24 PLYWOOD BACKING, BY COUNTERTOP FABRICATOR 09.16 PLASTIC LAMINATE CABINET, SEE SCHEDULE ON SHEET A6.03 09.20 RUBBER BASE, SEE SCHEDULE ON SHEET A6.03 09.22 PLASTIC LAMINATE PANEL, SEE SCHEDULE ON SHEET A6.03 09.24 FIBERGLASS REINFORCED PANEL (FRP-1), SEE SCHEDULE ON SHEET A6.03 09.35 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 14/A4.02 AND SEE SCHEDULE ON SHEET A6.03 09.37 P-LAM ADJUSTABLE SHELF, SEE SCHEDULE ON SHEET A6.03 09.44 SOLID SURFACE EDGE (SS-1) WITH 1/8" FILLET ON TOP EDGES 09.48 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 13/A4.02 AND SEE SCHEDULE ON SHEET A6.03 09.63 STAINLESS STEEL COUNTERTOP 10.47 PAPER TOWEL DISPENSER, BY OWNER 11.05 OWNER PROVIDED EQUIPMENT 11.09 SAFE #23, COORDINATE STUB UP TO BE NEXT TO EQUIPMENT (NOT BEHIND) SEE ELECTRICAL 11.10 SNEEZE GUARD, PROVIDED AND INSTALLED BY MILLWORK VENDOR 11.11 UNDERCOUNTER BAG DISPENSER PROVIDED BY OWNER, INSTALLED BY CONTRACTOR 26.09 MICROPHONE, SEE ELECTRICAL SCALE:6" = 1'-0"14 COUNTERTOP EDGE DETAIL PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 3 3 P M ENLARGED RETAIL PLANS & ELEVATIONS 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A4.02 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:6" = 1'-0"15 SOLID SURFACE COUNTERTOP DETAIL GENERAL NOTES 1. ALL MILLWORK AT WET LOCATIONS TO BE CONSTRUCTED WITH STYLELITE PANELS (BOTTOM OF GARBAGE, BOTTOM OF CABINETS WITH PENETRATIONS, SINK CABINETS). SCALE:1/2" = 1'-0"1 CASH WRAP COUNTER PLAN SCALE:1/2" = 1'-0"2 CASH WRAP ELEVATION SCALE:1/2" = 1'-0"5 CASH WRAP ELEVATION SCALE:1/2" = 1'-0"3 CASH WRAP ELEVATION SCALE:1/2" = 1'-0"4 CASH WRAP ELEVATION SCALE:1/2" = 1'-0"6 DRINK WALL COUNTER PLAN SCALE:1/2" = 1'-0"7 DRINK WALL ELEVATION SCALE:1/2" = 1'-0"10 DELI COUNTER PLAN SCALE:1/2" = 1'-0"11 DELI ELEVATION SCALE:1/2" = 1'-0"12 DELI ELEVATION GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 SCALE:1/2" = 1'-0"16 FLOATING TOP ELEVATION SCALE:1/2" = 1'-0"8 KITCHEN SERVICE SINK PLAN SCALE:1/2" = 1'-0"9 SINK ELEVATION 01/20/23 A4.03 16 A4.03 17 A4.03 18 5' - 9 3/8" 2 ' - 0 " 3 ' - 0 1 /2 " 5 ' - 6 " 1' - 8 1/8" 11.0509.22 11.05 TRASH 1' - 4 3/8"1' - 4 3/8"1' - 4 3/8"1' - 6 1/8" 5' - 7 3/8"4 1 /2 " 2 ' - 3 1 /2 " 2 " 2 ' - 2 " 5 " 2 ' - 1 0 " 09.20 09.16 09.48 09.22 5' - 4" 4 1 /2 " 2 ' - 3 1 /2 " 2 " 2 ' - 1 0 " 09.20 09.16 09.48 09.22 4' - 1 1/4"1' - 6 1/8" 5' - 7 3/8" 09.20 09.16 09.48 09.22 4 1 /2 " 2 ' - 3 1 /2 " 2 " 5 " 2 ' - 1 0 " 1' - 6"8' - 11"1' - 6" 11' - 11" 1 ' - 6 " 2 ' - 6 " 1 ' - 6 " 5 ' - 6 " 09.48 A4.03 4 A4.03 5 A4.03 A4.03 7 8 TYP. 11.05 A4.03 11 A4.03 A4.03 12 13 09.22 8' - 0" 4 ' - 7 1 /2 " E Q E Q 09.48 11.05 11.05 A4.032 10.47 TRASH 1" 1' - 8"1' - 8"1' - 8"1' - 4 1/2"1' - 4 1/2"1' - 8"1' - 8"1' - 9" 1"13' - 0"5 1 /2 " 2 ' - 2 1 /2 " 2 " 4 " 6 " 2 ' - 1 0 " 09.35 09.20 09.2309.23 09.16 09.20 ANGLED 1' - 5 1/2"1' - 5 1/2"1' - 6 1/4"1' - 3"2' - 8 1/2"5"ANGLED 11' - 8" 1 1 /2 " 2 ' - 3 " 5 1 /2 " 2 ' - 1 0 " TRASH 6 " 09.48 5 1 /2 " 2 ' - 3 " 1 1 /2 " ANGLED 2' - 4 3/4"ANGLED 5' - 3" 09.48 09.16 09.20 11.05 09.23 6 " 2 ' - 1 0 " ANGLED8' - 9 3/4"ANGLED 11' - 8"5 1 /2 " 2 ' - 3 " 1 1 /2 " 2 ' - 1 0 "09.16 09.48 09.20 11.05 ANGLED2' - 4 3/4"ANGLED 5' - 3" 11.05 09.48 09.16 09.20 5 1 /2 " 2 ' - 3 " 1 1 /2 " 2 ' - 1 0 " 09.23 6 " TRASH 09.48 09.16 09.20 09.22 4 1 /2 " 2 ' - 3 1 /2 " 2 " 5 " 2 ' - 1 0 " 6 3/4" 1' - 3"2' - 0 1/8"2' - 0 1/8"2' - 0 1/8" 3/4" 09.48 09.16 09.20 09.22 TRASH 6 3/4"1' - 3"2' - 0 1/8"2' - 0 1/8"2' - 0 1/8" 3/4"7' - 11" 2 ' - 2 " 2 " 2 ' - 3 1 /2 " 4 1 /2 " 2 ' - 1 0 " 5 " 09.48 09.16 09.20 09.22 4' - 4 1/2" 4 1 /2 " 2 ' - 3 1 /2 " 2 " 2 ' - 1 0 " A4.03 14 V.I.F. 2' - 7" V .I .F . 6 ' - 7 5 /8 " 09.35 OPEN CABINET TOWARD RETAIL 3"26"24"24"3" 3 ' - 6 " 2 ' - 4 " 2 ' - 6 1 /2 " 4 " 2 ' - 0 1 /2 " 2 " 1' - 3"1' - 3"2' - 10 5/8"1' - 3" 09.15 09.16 09.35 09.16 09.20 KEYED NOTES 09.15 5/8" GYPSUM WALL BOARD, PAINT COLOR PER ROOM FINISH SCHEDULE 09.16 PLASTIC LAMINATE CABINET, SEE SCHEDULE ON SHEET A6.03 09.20 RUBBER BASE, SEE SCHEDULE ON SHEET A6.03 09.22 PLASTIC LAMINATE PANEL, SEE SCHEDULE ON SHEET A6.03 09.23 PLASTIC LAMINATE FINISH CAP, SEE SCHEDULE ON SHEET A6.03 09.35 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 14/A4.02 AND SEE SCHEDULE ON SHEET A6.03 09.48 SOLID SURFACE COUNTERTOP, SEE DETAIL ON 13/A4.02 AND SEE SCHEDULE ON SHEET A6.03 10.47 PAPER TOWEL DISPENSER, BY OWNER 11.05 OWNER PROVIDED EQUIPMENT PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 3 4 P M ENLARGED RETAIL PLANS & ELEVATIONS 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A4.03 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 GENERAL NOTES 1. ALL MILLWORK AT WET LOCATIONS TO BE CONSTRUCTED WITH STYLELITE PANELS (BOTTOM OF GARBAGE, BOTTOM OF CABINETS WITH PENETRATIONS, SINK CABINETS). SCALE:1/2" = 1'-0"15 WARMER ISLAND COUNTER PLAN SCALE:1/2" = 1'-0"16 WARMER ISLAND ELEVATION SCALE:1/2" = 1'-0"17 WARMER ISLAND ELEVATION SCALE:1/2" = 1'-0"18 WARMER ISLAND ELEVATION SCALE:1/2" = 1'-0"6 HOT DOG ISLAND COUNTER PLAN SCALE:1/2" = 1'-0"10 COFFEE ISLAND COUNTER PLAN SCALE:1/2" = 1'-0"1 COFFEE WALL COUNTER PLAN SCALE:1/2" = 1'-0"2 COFFEE WALL ELEVATION SCALE:1/2" = 1'-0"4 HOT DOG ISLAND ELEVATION SCALE:1/2" = 1'-0"5 HOT DOG ISLAND ELEVATION SCALE:1/2" = 1'-0"7 HOT DOG ISLAND ELEVATION SCALE:1/2" = 1'-0"8 HOT DOG ISLAND ELEVATION SCALE:1/2" = 1'-0"11 COFFEE ISLAND ELEVATION SCALE:1/2" = 1'-0"12 COFFEE ISLAND ELEVATION SCALE:1/2" = 1'-0"13 COFFEE ISLAND ELEVATION SCALE:1/2" = 1'-0"9 OFFICE COUNTER PLAN SCALE:1/2" = 1'-0"14 OFFICE COUNTER ELEVATION GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 3 NOT USED 01/20/23 STAINLESS STEEL CORNER GUARD CAULK AT DISSIMILAR MATERIALS (TYP.) 2" MIN. 3 " 1/4" TO 1/2" SPACE CEILING SUSPENSION GRID WALL ANGLE; FASTEN TO WALL FINISHED WALL METAL 2X4 CEILING SUSPENSION SYSTEM. WITH VINYL COATED PANELS 3" MIN. 8" MAX. HANGER WIRE. 12'-0" TYP.1 2 '-0 " T Y P . 6 '-0 " M A X . C R O S S R U N N ER S MAIN RUNNERS W ALL ANGLE 8" MAX. CEILING AREAS OF 144 SQ. FT. OR LESS SURROUNDED BY WALLS WHICH CONNECT DIRECTLY TO THE STRUCTURE ABOVE SHALL NOT REQUIRE THE DIAGONAL BRACING WIRES. EACH VERTICAL WIRE SHALL BE ATTACHED EACH END WITH MIN. 3 TURNS. CEILING GRID SHALL BE INSTALLED LEVEL TO WITHIN 1/8" IN 12'. ALL WIRE LOOPS SHALL BE TIGHTLY WRAPPED AND SHARPLY BENT. FOR CEILING AREAS EXCEEDING 1,000 S.F. HORIZONTAL RESTRAINT OF THE CEILING TO THE STRUCTURE SHALL BE PROVIDED. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED AND BRACED INDEPENDENTLY OF THE CEILING. SUSPENDED CEILING SHALL BE SUBJECT TO THE SPECIAL INSPECTION REQUIREMENTS OF SECTION 1704. CEILING AREAS OF 1000 SQ. FT. OR LESS SURROUNDED BY WALLS WHICH CONNECT DIRECTLY TO THE STRUCTURE ABOVE SHALL NOT REQUIRE THE DIAGONAL BRACING WIRES. LOCAL KINKS OR BENDS SHALL NOT BE MADE IN HANGER WIRES AS A MEANS OF LEVELING MAIN RUNNERS. A HEAVY DUTY T-BAR SYSTEM SHALL BE USED. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL NOT BE LESS THAN 2 INCHES. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 0.75 INCH CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON THE CLOSURE ANGLE. A5.11 7 VERTICAL WIRES - 12 GA. 2" M A X. 2" M A X. MAIN RUNNERCROSS R U N N E R PROVIDE VERTICAL STRUT OF CONTINUOUS LENGTH OF CEILING GRID MATERIAL OR OTHER APPROVED LIGHT METAL FRAMING MATERIAL ATTACHED TO MAIN RUNNER AND TO STRUCTURE ABOVE TO COUNTERACT UPLIFTING FORCES OF SPLAYED WIRES.SPLAY WIRES - 12 G.A. @ 12'-0" O.C. IN PLANE OF EACH RUNNER. TIE BOTH ENDS W/ MIN. 3 TURNS IN 1" OF RUN TYPICAL. ALL CEILING MOUNTED LIGHT FIXTURES SHALL BE ATTACHED TO SUSPENDED CEILING GRID, IN ADDITION 12 GA. HANGER WIRES SHALL BE ATTACHED TO THE GRID WITHIN 3" OF EACH CORNER OF THE FIXTURE. TWO ADDITIONAL WIRES SHALL BE CONNECTED TO THE LIGHT HOUSING AND TO THE STRUCTURE ABOVE (THESE WIRES MAY BE SLACK). WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT, NOR SHALL THEY BE CLOSER THAN 5" FROM ANY UN-BRACED HORIZONTAL PIPING OR DUCTWORK. A TRAPEZE OR SIMILAR DEVICE SHALL BE USED WHERE OBSTRUCTIONS OCCUR. VERTICAL WIRES 12 GA. @ 4'-0" O.C. FASTEN WIRES TO BOTTOM OF TRUSS CORD WITH HILTI EYE LAG CEILING HANGER - 1/4" EL WS. OR APPROVED EQUAL. 4 5 ° M A X . 4 5 ° M A X . 4 5 ° M A X . 4 5 ° M A X . NOTE: PROVIDE ADDITIONAL SEISMIC BRACING AS REQUIRED 3 /4 " M I N U S 1 /4 " C L E A R L E N G T H MINUS 1/4" CLEAR LENGTH 3/4" PLAN A 9 " 3/4" 3 " SECTION B SECTION C NOTE: ALL FLOOR SINKS SHALL BE SEALED WITH WHITE PLUMBERS CAULK AS REQUIRED. 3/4" 22.0822.08 NOTE: GOES IN BASE CABINET WITH FLOOR SINK (5 LOCATIONS). 7 ' - 9 " 05.41 10.26 05.35 7 ' - 9 " 1 ' - 1 1 /2 " 4' - 5 3/8" 7 7/8" 7 7 /8 " 10.2310.23 3' - 3" 8 ' - 6 " 05.41 10.18 05.35 8 ' - 6 " 2 ' - 0 " 2' - 6" 1' - 3 3/4" 1 ' - 3 3 /4 " 10.18 EXISTING DROP PARTITION. NEW WALL GRAPHIC, SEE SHEET A2.51 COORDINATE ATTACHMENT WITH STRUCTURAL METAL STUD FRAMING, SEE STRUCTURAL SIGN, OWNER FURNISHED, CONTRACTOR INSTALLED. C-CHANNEL, BRITE RED. NO PENETRATIONS ALLOWED THROUGH FACE OF C CHANNEL. METAL SOFFIT PANEL, COLOR: C-2 2" X 6" BRAKE METAL TRIM, BRITE REDJ-MOLD, BRITE RED ANGLE WELDED TO C CHANNEL, SEE STRUCTURAL 9 ' - 0 " 1 3/4" 1 3 /4 " 1 3 /4 " A PLAN BASE OF CABINET FIELD VERIFY 1 3/4" B SECTION 07.19 07.18 6 " 3 1 /2 " F I E L D V E R I F Y 05.29 MECHANICAL EQUIPMENT -SEE MECHANICAL DRAWINGS SEE MECHANICAL FOR EQUIPMENT ATTACHMENT ROOFING TERMINATION BAR WITH APPROVED FASTENERS @ 6" O.C. TYP. EQUIPMENT CURB WITH PT. WOOD NAILER AT TOP OF CURB MEMBRANE FLASHING COMPATIBLE WITH EXISTING ROOF MEMBRANE PROVIDE CONTINUOUS SEALANT AT INTERSECTION OF WOOD BLOCKING TO CURB. -TYP. CONT. SEALANT TAPE AT TOP OF CURB -TYP. SEALANT, TYP. CONT. STEEL CHANNEL, SEE STRUCTURAL EXISTING ROOF MEMBRANE, PROTECT DURING CONSTRUCTION SEE STRUCTURAL CURB ATTACHMENT PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 3 5 P M DETAILS 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A5.11 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 CORNER GUARD DETAIL SCALE:1 1/2" = 1'-0"5 ACOUST. TILE/WALL SCALE:1/8" = 1'-0"6 SUSPENDED CEILING BRACING SCALE:3/8" = 1'-0"7 SEISMIC BRACING SCALE:1 1/2" = 1'-0"4 STAINLESS STEEL SINK SURROUND SCALE:1/2" = 1'-0"8 FOOD AREA TV-SIDE VIEW SCALE:1/2" = 1'-0"9 FOOD AREA TV-FRONT VIEW SCALE:1/2" = 1'-0"10 CASHWRAP TV-SIDE VIEW SCALE:1/2" = 1'-0"11 CASHWRAP TV-FRONT VIEW SCALE:1/2" = 1'-0"12 BONFIRE CANOPY SCALE:3" = 1'-0"2 STAINLESS STEEL PIPE APRON (PLATE) KEYED NOTES 05.29 1/8" THICK STAINLESS STEEL PLATE WITH #6 SATIN FINISH AND BEVELED EDGES 05.35 STEEL BRACKET, PAINTED BLACK, COORDINATE WITH STRUCTURAL 05.41 STEEL PIPE, COORDINATE WITH STRUCTURAL 07.18 BACKER ROD 07.19 SILICONE SEALANT, CONTINUOUS. SEE SCHEDULE FOR COLOR 09.10 STAINLESS STEEL CORNER GUARD 09.12 CAULK AT DISSIMILAR MATERIALS (TYP.) 10.18 75" TV PROVIDED BY OWNER SCALE:3" = 1'-0"13 MECH CURB DETAIL GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10.23 10" WIDE ACCESS FOR CABLE MANAGEMENT 10.26 (2) 43" TV PROVIDED BY OWNER 22.08 18 GAUGE STAINLESS STEEL SINK #6 SATIN FINISH W/ 3/4" CONTINUOUS FLANGE AND 3/8" DIAMETER CROSS BAR. FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION 3 NOT USED 01/20/23 INTERIOR FINISH SCHEDULE Number Name Floor Finish Base Finish Wall - BK Wall - FT Wall - L Wall - R Ceiling Finish Ceiling Height NOTES 101 RETAIL EXIST EXIST GWB (P-7, TYPICAL) GWB (P-1)GWB (P-1)GWB (P-1) EXPOSED (P-7)ALL HEADERS/SOFFITS TO BE P-7 U.N.O. 102 WOMEN'S EXIST EXIST CT-1/G-1, GWB (P-1) CT-1/G-1, GWB (P-1) CT-1/G-1, GWB (P-1) CT-1/G-1, GWB (P-1) GWB (P-7) EXIST ACCESS PANELS TO MATCH ADJACENT MATERIAL COLOR 103 MEN'S EXIST EXIST CT-1/G-1, GWB (P-1) CT-1/G-1, GWB (P-1) CT-1/G-1, GWB (P-1) CT-1/G-1, GWB (P-1) GWB (P-7) EXIST ACCESS PANELS TO MATCH ADJACENT MATERIAL COLOR 104 EXIT HALLWAY EXIST EXIST GWB (P-1)GWB (P-1)GWB (P-1)GWB (P-1)GWB (P-7) EXIST 105 DELI PREP EXIST EXIST -MATCH EXIST TILE MATCH EXIST FRP EXIST P-7 SEE RCP FOR EXTENT MATCH EXIST SEE REFERENCE PLAN FOR FRP & TILE LOCATION. ALL HEADERS/SOFFITS TO BE P-7 U.N.O., MATCH EXISTING WALL TILE HEIGHT 106 KITCHEN SERVICE EXIST EXIST EXIST MATCH EXIST FRP MATCH EXIST FRP EXIST MATCH EXIST ACT MATCH EXIST 109 OFFICE EXIST EXIST GWB (P-1)GWB (P-1)GWB (P-1)GWB (P-1)ACT-1 10' - 0" 110 30° BEER COOLER CT-4 -EXIST EXIST EXIST EXIST EXIST EXIST 112 STORAGE CT-4 RB-1 EXIST EXIST EXIST EXIST OPEN 114 STORAGE EXIST -EXIST EXIST EXIST EXIST EXIST EXIST MATERIAL SCHEDULE CODE DESCRIPTION MFR.NAME COLOR/FINISH COMMENTS 1. TILE/GROUT CT-1 12" X 24" PORCELAIN TILE EMSER PERSPECTIVE BROWN W/ G-2 GROUT, W/ "A100 ABGB" (SCHLUTER-JOLLY TRIM).STAGGERED VERTICAL BRICKWORK PATTERN. REFER TO NATIONAL ACCOUNT INFORMATION ON G0.01. CT-2 6" X 6" CERAMIC TILE EMSER EQUARRY SMOKE W/ COVE BASE, W. G-1 GROUT. REFER TO NATIONAL ACCOUNT INFORMATION ON G0.01. CT-3 4" x 12" WALL TILE EMSER LOGIC WHITE WHITE MATTE W/ G-1 GROUT. STAGGERED HORIZONTAL BRICKWORK PATTERN. SEE SHEET A1.07 FOR SS CORNER GUARD LOCATIONS. REFER TO NATIONAL ACCOUNT INFORMATION ON G0.01. CT-3 (ALT)4" X 10" WALL TILE EMSER FLEX WHITE MATTE W/ G-1 GROUT. STAGGERED HORIZONTAL BRICKWORK PATTERN. SEE SHEET A1.07 FOR SS CORNER GUARD LOCATIONS. REFER TO NATIONAL ACCOUNT INFORMATION ON G0.01. CT-4 9" X 36"EMSER SANCTUARY II - CUSTOM TAUPE W/ G-1 GROUT @ 33% OFFSET, W/ BLACK RUBBER BASE (RB-1). REFER TO NATIONAL ACCOUNT INFORMATION ON G0.01. G-1 GROUT CUSTOM BUILDING PRODUCTS -#540 TRUFFLE G-2 GROUT CUSTOM BUILDING PRODUCTS -#185 NEW TAUPE 2. RUBBER BASE RB-1 6" WALL BASE JOHNSONITE WALL BASE #40 BLACK 3. FIBERGLASS REINFORCED PANEL FRP-1 FIBERGLASS PANEL --MANUFACTURER'S STANDARD WHITE SMOOTH NOTE: FRP SHOULD BE CUT FROM 12' PANELS ONLY. ALL INSIDE AND OUTSIDE CORNERS AND DIVIDERS SHOULD BE CUT ABOVE RUBBER BASE BY RUBBER BASE INSTALLER TO ENSURE TRIMS MEET BASE ELEVATIONS. NO RUBBER BASE OVER THE TOP OF ANY FRP TRIMS. CEILING SUB SHOULD CUT ALL FRP TRIMS AT CEILING ELEVATION. NO L METAL OVER THE TOP OF FRP TRIMS. 4. PAINTED SURFACES P-1 LATEX PAINT SHERWIN WILLIAMS #6120 BELIEVABLE BUFF P-2 LATEX PAINT SHERWIN WILLIAMS #6385 DOVER WHITE P-3 LATEX PAINT SHERWIN WILLIAMS #7043 WORLDLY GRAY P-4 PRIMER (EXTERIOR GRADE)-SW "SAFETY RED" P-5 PRIMER INTERIOR GRADE)SHERWIN WILLIAMS GRAY P-6 LATEX PAINT SHERWIN WILLIAMS #7019 GAUNTLET GRAY P-7 LATEX PAINT SHERWIN WILLIAMS #6225 SLEEPY BLUE P-8 LATEX PAINT SHERWIN WILLIAMS WHITE VERIFY COLOR WITH OWNER P-9 POWDER COAT SHERWIN WILLIAMS #7020 BLACK FOX 5. ACOUSTICAL TILE ACT-1 ACOUSTICAL TILE U.S.G.MANUF. STANDARD WHITE VINYL COATED 6. SOLID SURFACE SS-1 SOLID SURFACE CORIAN PINE GENERAL COUNTERTOPS, WINDOW SILLS, BONFIRE WALL CAP 8. BATHROOM PARTITIONS PT-1 BATHROOM PARTITION BOBRICK PARTITION SIERRA SERIES SC-02 DESERT BEIGE SOLID COLOR REINFORCED COMPOSITE. PARTITION LATCH BOBRICK MODEL 1002612 11. PLASTIC LAMINATE BASE CABINETS, COUNTERTOPS, AND SHELVES PL-1 PLASTIC LAMINATE WILSONART OLD MILL OAK 7973 GENERAL CABINETS PL-2 PLASTIC LAMINATE WILSONART RUSTIC SLATE 4888-38 BONFIRE GRILL WALL 13. SEALANTS SEL-2 SEALANT MATCH COLOR AST-1 MATCH COLOR AST-1 SEL-3 SEALANT BLACK BLACK SEE SPECIFICATIONS SEL-4 SEALANT MATCH COLOR P-1 MATCH COLOR P-1 SEE SPECIFICATIONS SEL-5 SEALANT MATCH COLOR SS-2 MATCH COLOR SS-2 SEL-6 SEALANT L&M (LATICRETE)SEAL HARD CLEAR 14. STANDING SEAM METAL ROOF C-2 INTERIOR METAL SOFFIT MBCI BRITE RED PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 8 / 2 0 2 3 3 : 0 8 : 3 5 P M FINISH & MATERIAL SCHEDULES 2022020.40 FINAL DRAWINGS 01/20/2023 KM AC TYPE B REMODEL A6.03 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 DESIGN CRITERIA: STRUCTURAL DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING CODE. LIVE LOADS: ROOF LOAD = 20 PSF (REDUCIBLE AS PER CODE) FLOOR SLAB-ON-GRADE = 100 PSF DEAD LOADS: ROOF LOAD = 20 PSF WIND LOADS: ULTIMATE WIND SPEED, Vult (3 sec. GUST) = 105 MPH NOMINAL WIND SPEED, Vasd (3 sec. GUST) = 81 MPH WIND IMPORTANCE FACTOR ( I w) = 1.0 RISK CATEGORY: II WIND EXPOSURE = C ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = +0.18 or -0.18 SEISMIC LOADS: SEISMIC IMPORTANCE FACTOR:1.0 RISK CATEGORY:II MAPPED ACCELERATIONS: Ss:0.361g S1:0.141g SITE CLASS DEFINITION:D (ASSUMED) SPECTRAL RESPONSE COEF: Sds:0.364 Sd1:0.218 SEISMIC DESIGN CATEGORY: D RESPONSE MODIFICATION FACTOR (R): 6 1/2 SEISMIC FORCE RESISTING SYSTEM: LIGHT FRAME (COLD FORMED STEEL) WALLS SHEATHED WITH WOOD STRUCTURAL PANEL RATED FOR SHEAR RESISTANCE. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE SNOW LOADS: GROUND SNOW LOAD (Pg):50 PSF SNOW EXPOSURE FACTOR (Ce):1.0 THERMAL FACTOR (Ct):1.0 SNOW IMPORTANCE FACTOR:1.0 FLAT ROOF SNOW LOAD (Pf):35 PSF CONCRETE NOTES: MINIMUM CONCRETE COMPRESSIVE STRENGTH, (f'c), AT 28 DAYS: 1. BUILDING SLAB:4000 PSI (EXPOSURE CLASS F0) CONCRETE PROPORTIONS SHALL CONSIST OF THE FOLLOWING MATERIALS TO ACHIEVE A MIX THAT WILL YIELD A FINISHED PRODUCT THAT WILL PRODUCE THE REQUIRED COMPRESSIVE STRENGTHS LISTED ABOVE. A. CEMENTITIOUS MATERIALS: a. PORTLAND CEMENT, ASTM C150, TYPE 1. b. 20% MAXIMUM FLY ASH IS ALLOWED. (ASTM C618, CLASS F) B. AGGREGATES: NORMAL WEIGHT ASTM C33 a. COMBINED AGGREGATE GRADATION FOR SLABS AND OTHER DESIGNATED CONCRETE SHALL BE 8% - 18% FOR LARGE TOP SIZE AGGREGATES (1 1/2") OR 8% - 22% FOR SMALLER TOP SIZE AGGREGATES (1" OR 3/4") RETAINED ON EACH SIEVE BELOW THE TOP SIZE AND ABOVE THE NO. 100. b. A GRADATION CHART OR TABLE SHALL BE SUBMITTED WITH MIX DESIGNS FOR SLAB ON GRADE. NOTIFY E.O.R. IF SPECIFIED GRADATION IS NOT LOCALLY AVAILABLE FOR AN ALTERNATE SPECIFICATION. c. MAXIMUM AGGREGATE SIZE SHALL NOT BE LARGER THAN: 1. 1/5 THE NARROWEST DIMENSION OF THE FORMS. 2. 1/3 THE DEPTH OF THE SLAB. 3. 3/4 THE MINIMUM CLEAR SPACING BETWEEN BARS. C. WATER: ASTM C94, POTABLE. D. AIR ENTRAINMENT ADMIXTURE: ASTM C260. E. WATER REDUCING ADMIXTURE: ASTM C494, TYPE F OR G. F. CALCIUM CHLORIDE: ANY ADMIXTURE CONTAINING MORE THAN 0.1% CHLORIDE IONS, CONTENT BY WEIGHT, ARE NOT PERMITTED. CONCRETE MIX DESIGNS MUST BE SUBMITTED TO THE E.O.R. FOR HIS APPROVAL BEFORE CONSTRUCTION BEGINS. MIX DESIGNS MUST BE SUBMITTED WITH COMPRESSIVE STRENGTH INFORMATION, FOR THAT SPECIFIC MIX, AS PER THE REQUIREMENTS OF CHAPTER 5 OF ACI-318-14. SUBMISSIONS WITHOUT THIS INFORMATION WILL BE STAMPED "REJECTED" & RETURNED TO THE CONTRACTOR WITHOUT E.O.R. REVIEW. TEST DATA SHALL BE NO OLDER THAN 12 MONTHS. ALL CONCRETE COMPRESSIVE STRENGTH TESTS SHALL BE AVAILABLE ON THE JOB SITE FOR REVIEW BY THE INSPECTOR. STRUCTURAL MEMBERS OF REINFORCED CONCRETE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CODE REFERENCED ACI 318-14. SLAB ON GRADE CONTROL OR CONSTRUCTION JOINTS SHALL BE LOCATED AT COLUMN LINES AND INTERMEDIATELY SO THAT NO JOINT SPACING SHALL EXCEED 12'-0", NOR SHALL THE LENGTH OF ANY PANEL EXCEED ONE AND A HALF, (1 1/2), TIMES THE WIDTH OF THAT PANEL. REFER TO TYPICAL DETAILS FOR SLAB JOINT CONSTRUCTION. FLOOR SLAB CONSTRUCTION JOINTS MUST BE DOWELED. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SLAB FINISHES, SLOPES AND DEPRESSIONS OF INTERIOR SLABS. PROVIDE (2)#4 REINFORCING BARS, 3'-0" LONG, IN CONCRETE SLABS AT ALL RE- ENTRANT CORNERS. PLACE BARS AT MID DEPTH OF SLAB WITH 2" MINIMUM HORIZONTAL CLEARANCE FROM SLAB CORNER. REINFORCING STEEL NOTES: SHALL BE DETAILED, FABRICATED AND PLACED ACCORDING TO THE STANDARDS OF THE AMERICAN CONCRETE INSTITUTE (ACI) AND THE CONCRETE REINFORCING STEEL INSTITUTE (CRSI). MATERIALS: REINFORCING BARS SHALL COMPLY WITH ASTM A615 GRADE 60. WELDED WIRE FABRIC SHALL COMPLY WITH ASTM A82 AND A1064, FLAT SHEETS ONLY. REINFORCING BARS FOR WELDING SHALL COMPLY WITH ASTM A706. CLEAR MINIMUM COVER OF CONCRETE OVER REINFORCING BARS SHALL BE AS FOLLOWS: CONCRETE PLACED AGAINST EARTH .........................................3" FORMED SURFACES EXPOSED TO EARTH ............................ ......2" TOP OF SLABS ........................................................................... 3/4" ALL BARS DENOTED CONTINUOUS ON PLANS, SECTIONS AND DETAILS SHALL HAVE CLASS "B" TENSION SPLICE LAPS AND CORNER BARS AND HOOKS AT DISCONTINUOUS ENDS. SPLICED BARS SHALL BE SECURELY WIRED TOGETHER. SPLICES OF ADJACENT REINFORCING BARS SHALL BE STAGGERED 24" WHEREVER POSSIBLE. WELDED WIRE FABRIC, WHERE REQUIRED, SHALL BE PLACED IN THE CENTER OF THE SLAB UNLESS NOTED OTHERWISE. LAP JOINTS ONE WIRE SPACING PLUS 2" OR A MINIMUM OF 6". EXTEND FABRIC TO WITHIN 1" OF EDGES OF SLABS ON GRADE. PROVIDE PRECAST DOBIES, WIRE OR PLASTIC CHAIRS, SUPPORT BARS, ETC. TO MAINTAIN SPECIFIED CLEARANCES FOR THE ENTIRE LENGTH OF ALL REINFORCING BARS AND WELDED WIRE FABRIC. DO NOT USE REBAR STAKES TO SUPPORT REINFORCING. ALL REINFORCEMENT SHALL BE FASTENED AND SECURED TO PREVENT DISPLACEMENT BY THE PLACING OF CONCRETE. ALL CONCRETE WALLS TO BE DETAILED IN ELEVATION ON SHOP DRAWINGS. NO MORE THAN 50% OF HORIZONTAL WALL REINFORCING SHALL LAP IN A SINGLE VERTICAL PLANE. PROVIDE (2) #4 REINFORCING BARS, 4'-0" LONG, IN CONCRETE SLABS AT ALL RE-ENTRANT CORNERS. PLACE BARS AT MID DEPTH OF SLAB WITH 2" MINIMUM HORIZONTAL CLEARANCE FROM SLAB CORNER. REBAR FOR WELDED CONNECTIONS MUST MEET ASTM A706. STANDARD ASTM A615 GRADE 60 REBARS ARE NOT ACCEPTABLE FOR WELDING. WELDING PROCEDURE SHALL CONFORM TO ANSI/AWS D1.4 "STRUCTURAL WELDING CODE - REINFORCING STEEL". DO NOT TACK WELD. REINFORCING DOWELS, WHERE REQUIRED, SHALL MATCH THE SIZE, SPACING AND QUANTITY OF MAIN REINFORCING, UNLESS NOTED OTHERWISE. TYPICAL DETAILS AND GENERAL NOTES APPLY TO ALL PARTS OF THE WORK EXCEPT WHERE SPECIFICALLY DETAILED OR UNLESS OTHERWISE NOTED. DRAWINGS ARE NOT TO BE SCALED. FOR DIMENSIONS NOT SHOWN, COORDINATE WITH ARCHITECTURAL DRAWINGS. THE CONTRACTOR SHALL CAREFULLY REVIEW THE DRAWINGS TO IDENTIFY THE SCOPE OF WORK REQUIRED, VISIT THE SITE TO RELATE THE SCOPE OF WORK TO EXISTING CONDITIONS, AND DETERMINE THE EXTENT OF WHICH THOSE CONDITIONS AND PHYSICAL SURROUNDINGS WILL IMPACT THE WORK. EXISTING CONDITIONS, AS SHOWN ON THESE PLANS, ARE FOR REFERENCE ONLY. THE CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL ASSUME THE MOST STRINGENT REQUIREMENTS APPLY IN CASE OF CONFLICT AMONG SPECIFICATIONS, STANDARDS, CODES AND DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY TO RESOLVE THE CONFLICT. ANY DEVIATION, MODIFICATION, OR SUBSTITUTION FROM THE BID SET OF STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER FOR REVIEW/APPROVAL PRIOR TO ITS USE OR INCLUSION ON THE SHOP DRAWINGS. WITHOUT SUCH PRIOR APPROVAL, DEVIATIONS, MODIFICATIONS, OR SUBSTITUTIONS WILL BE REJECTED. COSTS FOR DEMOLITION AND REWORK OF SUCH ITEMS WILL BE BORNE BY THE CONTRACTOR. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE WORK IS COMPLETE. THE MEANS, METHODS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR, WHICH INCLUDE THE DETERMINATION OF ALLOWABLE CONSTRUCTION LOADING OF THE STRUCTURE. THE CONTRACTOR SHALL PROVIDE, DESIGN, MONITOR, AND MAINTAIN ALL NECESSARY TEMPORARY AND PERMANENT SYSTEMS (SHORING, BRACING, GUYS, FALSEWORK, FORMWORK, SHEETING, ETC.) TO ENSURE THE INTEGRITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. ANY SYSTEMS SHOWN ON THE DOCUMENTS ARE PARTIAL AND SCHEMATIC IN NATURE AND EXTENTS ARE NOT ALL INCLUSIVE. ALL WORK SHALL BE PERFORMED WITHOUT DAMAGE TO ADJACENT EXISTING WORK. SHORING SYSTEMS SHALL BE DESIGNED, SIGNED, AND SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE JURISDICTION WHERE THE PROJECT IS LOCATED. THE CONTRACTOR IS RESPONSIBLE FOR SITE SAFETY. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW THE STRUCTURAL CONTRACT DOCUMENTS AND SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY CONFLICTS BETWEEN THOSE DOCUMENTS AND ANY SAFETY REGULATIONS. SUCH REVIEW AND NOTIFICATION SHALL OCCUR PRIOR TO PRODUCTION OF SHOP DRAWINGS. THE CONTRACTOR SHALL PROTECT ALL WORK, MATERIALS, AND EQUIPMENT FROM DAMAGE AND SHALL PROVIDE PROPER STORAGE FACILITIES FOR MATERIALS AND EQUIPMENT DURING CONSTRUCTION. SITE VISITS PERFORMED BY THE ARCHITECT/ENGINEER DO NOT INCLUDE INSPECTIONS OF MEANS AND METHODS OF CONSTRUCTION PERFORMED BY THE CONTRACTOR. STRUCTURAL OBSERVATIONS PERFORMED BY THE ARCHITECT/ENGINEER DURING CONSTRUCTION ARE NOT THE CONTINUOUS AND SPECIAL INSPECTION SERVICES AND DO NOT WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED OF THE BUILDING DEPARTMENT INSPECTOR OR THE TESTING AGENCY. ALSO, OBSERVATIONS DO NOT GUARANTEE THE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSIDERED AS SUPERVISION OF CONSTRUCTION. ALL WALLS, FLOORS, AND ROOF MEMBERS SHALL BE SECURELY SHORED AND BRACED AT ALL TIMES DURING CONSTRUCTION. NO PIPES OR DUCTS SHALL BE EMBEDDED INTO STRUCTURAL MEMBERS UNLESS SO SHOWN ON THE PLANS OR APPROVED BY THE ENGINEER. NO STRUCTURAL ELEMENTS ARE TO BE CUT UNLESS SPECIFICALLY APPROVED BY THE ENGINEER. GENERAL PROVISIONS: MATERIAL PROPERTIES: W SHAPES: ASTM A992 (Fy = 50 KSI) M,S,C SHAPES: ASTM A36 UNO PLATE, ANGLES: ASTM A36 UNO PIPE: ASTM A53, TYPE E OR S, GRADE B TUBE: ASTM A500, GRADE B (Fy = 46 KSI) DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO THE 2016 AISC SPECIFICATIONS. FIELD CONNECTIONS SHALL BE BOLTED, BEARING TYPE UNLESS NOTED OTHERWISE USING 3/4" HIGH STRENGTH BOLTS CONFORMING TO ASTM A325. ONE SIDED CONNECTIONS ARE NOT PERMITTED UNLESS DETAILED ON DRAWINGS GENERAL CONTRACTOR SHALL VERIFY ALL MECHANICAL EQUIPMENT LOCATIONS, OPENING DIMENSIONS AND WEIGHTS PRIOR TO STRUCTURAL STEEL FABRICATION. NOTIFY ENGINEER IF DIFFERENT FROM THAT SHOWN ON DRAWINGS. WHEN FORCES ARE NOT SHOWN, THE CONNECTION SHALL DEVELOP 1/2 OF THE ALLOWABLE UNIFORM LOAD AS SPECIFIED IN THE BEAM TABLES OF AISC (ASD). A MINIMUM OF 2 BOLTS SHALL BE USED. ALL WELDING SHALL BE DONE USING E-70XX ELECTRODES IN ACCORDANCE WITH THE AWS SPECIFICATIONS. FIELD VERIFY ALL CONDITIONS AT AND CONNECTIONS TO THE EXISTING CONSTRUCTION BEFORE FABRICATION. PRIME ALL STEEL NOT IN CONTACT WITH CONCRETE. DO NOT PRIME STEEL IN AREAS TO RECEIVE SLIP CRITICAL BOLTS (FRICTION BOLTS). DO NOT PRIME STEEL THAT IS TO RECEIVE FIREPROOFING. STRUCTURAL STEEL: COMPONENT AND CLADDING WALL PRESSSURE ZONES COMPONENT AND CLADDING ROOF PRESSSURE ZONES ELEVATION PLAN A A A = 9.5 FEET 45 5 A = 9.5 FEET 1 3 2 2 3 33 2 3 2 2 A A A A A A A A PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 1 0 : 3 8 : 0 0 A M GEN. STRUCTURAL NOTES 2022020.40 FINAL DRAWINGS 01/20/2023 DMH JNK TYPE B REMODEL S0.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 Notes: 1.TRIBUTARY PRESSURES ARE FOR THE SQUARE FOOT (SF) TRIBUTARY AREA SHOWN. FOR OTHER TRIBUTARY AREAS, LINEARLY INTERPOLATE BETWEEN VALUES SHOWN ABOVE. 2.POSITIVE PRESSURES ACT TOWARD THE BUILDING. NEGATIVE PRESSURES ACT AWAY FROM THE BUILDING. 3. ALL WIND PRESSURES IN THE TABLE ARE BASED ON ULTIMATE WINDSPEEDS. TO CONVERT TO NOMINAL WIND PRESSURES MULTIPLE VALUES BY 0.6. -29.0 psf -28.1 psf -26.9 psf 5 21.6 psf 21.2 psf 20.6 psf -23.5 psf -23.0 psf -22.5 psf 4 21.6 psf 21.2 psf 20.6 psf Walls: Zone:10 SF 50 SF 100 SF Overhang Zone 3 -60.7 psf -42.6 psf -20.0 psf Overhang Zone 2 -38.3 psf -37.4 psf -36.2 psf -60.7 psf -45.3 psf -26.1 psf 3 16.0 psf 16.0 psf 16.0 psf -40.3 psf -34.0 psf -26.1 psf 2 16.0 psf 16.0 psf 16.0 psf -24.0 psf -23.1 psf -22.0 psf Roof: 1 16.0 psf 16.0 psf 16.0 psf Zone:10 SF 50 SF 100 SF C&C Wind Pressures (105 MPH) GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 GENERAL: METAL STUD MANUFACTURER SHALL BE A MEMBER OF THE STEEL STUD MANUFACTURER'S ASSOCIATION (SSMA) METAL STUDS AND ACCESSORIES SHALL HAVE A G60 GALVANIZED COATING UNLESS NOTED OTHERWISE METAL STUD STRENGTH CRITERIA: A. GAUGES 20 THROUGH 18 - 33 KSI MIN. YIELD STRESS B. GAUGES 16 THROUGH 12 - 50 KSI MIN. YIELD STRESS C. TRACK RUNNER - 33 KSI MIN. YIELD STRESS METAL STUD MEMBER DESIGNATION: 600 S 162 - 33 WEB DEPTH: 600 = 6" MEMBER TYPE: S = STUD FLANGE WIDTH: 162 = 1.625" (1 5/8") MINIMUM THICKNESS IN MILS FASTENERS: FASTENING: WALL OPENING FRAMING: ALL STUDS CUT TO CREATE WALL OPENING MUST BE REPLACED WITH EQUAL FULL HEIGHT KING STUDS ON EACH SIDE OF THE OPENING. CURTAIN WALL AND NON LOAD BEARING PARTITIONS: MECHANICAL BRACING OF STUDS IS NOT NECESSARY WHERE WALL SHEATHING IS ATTACHED ON BOTH SIDES OF THE STUDS. WHEN ONLY ONE FACE OF THE STUDS RECEIVE SHEATHING, PROVIDE BRACING BY ONE OF THE FOLLOWING METHODS: VERTICAL SPACING OF THE BRACING IS LIMITED TO A MAXIMUM OF 4'-0" THROUGHOUT THE HEIGHT OF THE WALL. PROVIDE ALL ACCESSORIES AS REQUIRED BY THE METAL STUD MANUFACTURER. JOISTS SHALL BE FABRICATED TO PROVIDE 12" OF UNPUNCHED WEB AT BEARING ENDS. PROVIDE JOIST WEB STIFFENERS AT BEARING POINTS WHERE INDICATED ON THE PLANS. PROVIDE END BLOCKING WHERE JOISTS ARE NOT RESTRAINED AGAINST ROTATION. NO LIGHT GAUGE MEMBER, THAT HAS BEEN TRIMMED OR CUT, SHALL BE INSTALLED SO THAT AN EDGE OF A WEB PUNCH OUT OCCURS WITHIN 10" MINIMUM OF THE TRIMMED OR CUT MEMBER END. ALL MEMBER CUTTING MUST BE PERFORMED USING A SAW OR SHEAR. NO TORCH CUTTING IS ALLOWED AT ANY TIME. ALSO CUTTING OF ADDITIONAL HOLES, OTHER THAN THOSE PROVIDED BY THE MANUFACTURER, IN THE MEMBER WEB IS NOT PERMITTED AT ANY TIME. SPLICING OF AXIALLY LOADED MEMBERS IS NOT ALLOWED AT ANY TIME. BUILT UP LIGHT GAUGE HEADERS, CONSTRUCTED FOR EXTERIOR WALL CONDITIONS, SHALL HAVE INSULATION PLACED WITHIN THEM PRIOR TO THEIR INSTALLATION IN WALL SYSTEM. MILS GAUGE 33 20 43 18 54 16 68 14 97 12 SCREW CONNECTIONS FASTENING STUD TO STUD USE #10-16 TEKS/3 x 5/8" LONG BY ITW BUILDEX UNLESS OTHERWISE NOTED. MIN. EDGE DISTANCE = 3/4" MIN. SPACING BETWEEN FASTENERS = 3/4" POWDER ACTUATED FASTENERS (P.A.F.): FASTENING TO CONCRETE: USE 0.145" DIA. DOME HEAD NAIL BY HILTI, UNLESS NOTED OTHERWISE. MIN. EMBEDMENT = 1 1/4" MIN. EDGE DISTANCE = 2" MIN. SPACING BETWEEN FASTENERS = 3" FASTENING TO STEEL: USE 0.145" DIA. DOME HEAD KNURLED SHANK FASTENER BY HILTI, UNLESS NOTED OTHERWISE. MIN. EMBEDMENT = FULL PENETRATION MIN. EDGE DISTANCE = 1/2" MIN. SPACING BETWEEN FASTENERS = 1" A. B. MINIMUM FASTENING REQUIREMENTS, UNLESS NOTED OTHERWISE. TRACK TO CONCRETE: (2) FASTENERS AT 16" O.C. TYPICAL WITH ADDITIONAL FASTENER 3" FROM END OF TRACK AND (2) FASTENERS MINIMUM AT JAMBS. TRACK TO STRUCTURAL STEEL: 12" O.C. TYPICAL WITH ADDITIONAL FASTENER 3" FROM END OF TRACK AND (2) FASTENERS MINIMUM AT JAMBS. STUD TO TRACK: (1) SCREW MINIMUM AT EACH FLANGE STUD TO STUD: (3) SCREWS MINIMUM STUD TO STEEL OR CONCRETE: USE POWDER ACTUATED FASTENERS REFERENCED ABOVE. SEE DETAILS FOR CONNECTIONS, MINIMUM 2 FASTENERS. A. COLD ROLLED CHANNEL, RUN HORIZONTALLY THROUGH STUD PUNCH OUTS AND ATTACHED AT EACH STUD. 2" WIDE, 18 GAUGE, STEEL STRAPS RUN HORIZONTALLY, ON BOTH SIDES OF THE STUDS, AND ATTACHED AT EACH STUD. A. B. PRE-ENGINEERED COLD-FORMED STEEL FRAMING: AB ABV ALT APPROX ARCH BLDG BLW BM B.N. BOT BRG BTWN CC. CC-x CGS C.J. COL CONC CONST CP-x CTR CW-x DB DBA DBE DBL DET DIA DIM DN DWG DWL EA E.N. E.F. E.J. ELEC ELEV E.O.D. E.O.S. EQUIP EQ E.W. EXP EXT FC-x F.D. FDN F.F. F.N. FR-x FS-x FT FTG FTS-x GA GALV GSN HB HORIZ HSA HT ICC IBC I.F. IN INT JT JST ANCHOR BOLT(S) ABOVE ALTERNATE APPROXIMATE ARCHITECT(URAL) BUILDING BELOW BEAM BOUNDARY NAILING BOTTOM BEARING BETWEEN CENTER-TO-CENTER CONCRETE COLUMN CENTER OF GROSS STEEL CONST/CONTROL JOINT COLUMN CONCRETE CONSTRUCTION CONCRETE PIER CENTER CONCRETE WALL DECK BEARING DEFORMED BAR ANCHOR DECK BEARING ELEVATION DOUBLE DETAIL DIAMETER DIMENSION DOWN DRAWING DOWEL EACH EDGE NAILING EACH FACE EXPANSION JOINT ELECTRICAL ELEVATION EDGE OF DECK EDGE OF SLAB EQUIPMENT EQUAL EACH WAY EXPANSION EXTERIOR CONTINUOUS FOOTING MARK FLOOR DRAIN FOUNDATION FINISHED FLOOR FIELD NAILING RECTANGULAR FOOTING SQUARE FOOTING MARK FOOT FOOTING THICKEN SLAB MARK GAUGE GALVANIZED GENERAL STRUCTURAL NOTES HORIZONTAL BRIDGING HORIZONTAL HEADED STUD ANCHOR HEIGHT INTERNATIONAL CODE COUNCIL INTERNATIONAL BUILDING CODE INSIDE FAVE INCH INTERIOR JOIST JOINT k KLF KSF LBS LF LLH LLV LSH LSV MAX MECH MF-x MFR MIN MISC NIC NTS O.C. O.F. OPNG OPP OWSJ PAF PCF PL PLF PNL PSF PSI PT REINF REQD R.D. RTU SBP-x SCW SC-x SCP-x SHT SI SIM SMU SOG SQ STAG STD STL STR STS T&B TEMP THDS T.O. TOC TOD TOF TOS TOW TYP UNO VERT W/ WT WWF WWM KIP(S) = 1000 POUNDS KIPS PER LINEAL FOOT KIPS PER SQUARE FOOT POUNDS LINEAL FOOT LONG LEG HORIZONTAL LONG LEG VERTICAL LONG SIDE HORIZONTAL LONG SIDE VERTICAL MAXIMUM MECHANICAL MOMENT FRAME MANUFACTURER MINIMUM MISCELLANEOUS NOT IN CONTRACT NOT TO SCALE ON CENTER OUTSIDE FACE OPENING OPPOSITE OPEN WEB STEEL JOIST POWER-ACTUATED FASTENER POUNDS PER CUBIC FOOT PLATE POUNDS PER LINEAL FOOT PANEL POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT REINFORCING REQUIRED ROOF DRAIN ROOF TOP UNITS STEEL BASE PLATE MARK SEISMIC CRITICAL WELD STEEL COLUMN MARK STEEL CAP PLATE MARK SHEET SPECIAL INSPECTION SIMILAR SUSPENDED MECHANICAL UNITS SLAB-ON-GRADE SQUARE STAGGARD STANDARD STEEL STRUCTURAL SELF TAPPING SCREWS TOP AND BOTTOM TEMPERATURE THREADS TOP OF TOP OF CONCRETE TOP OF DECK TOP OF FOOTING TOP OF STEEL TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE VERTICAL WITH WALL THICKNESS WELDED WIRE FABRIC WELDED WIRE MESH LEGEND OF MARKS AND ABBREVIATIONS REPRODUCTION OF THE STRUCTURAL DRAWINGS FOR USE IN PREPARATION OF SHOP DRAWINGS IS STRICTLY PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER OF RECORD. SHOP DRAWINGS SUBMITTED WITH REPRODUCED STRUCTURAL DRAWINGS AND/OR DETAILS WITHOUT CONSENT WILL BE REJECTED. SUBMIT SHOP DRAWINGS 15 BUSINESS DAYS (MINIMUM) PRIOR TO DATE THAT RETURNED SHOP DRAWINGS ARE REQUIRED. SHOP DRAWINGS SHALL BEAR THE CONTRACTORS STAMP OF APPROVAL, WHICH SHALL CONSTITUTE CERTIFICATION THAT ALL FIELD MEASUREMENTS, CONSTRUCTION CRITERIA, AND MATERIALS SPECIFIED IN THE CONTRACT DOCUMENTS HAVE BEEN VERIFIED AND EACH DRAWING HAS BEEN CHECKED FOR COMPLETENESS, COORDINATION, AND COMPLIANCE WITH THE CONTRACT DOCUMENTS. CONTRACTOR SHALL REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL, LAUNDRY AND FOOD SERVICE DRAWINGS FOR SIZE AND LOCATIONS OF OPENINGS, SLEEVES, CONCRETE HOUSEKEEPING PADS, INSERTS, AND DEPRESSIONS DURING SHOP DRAWING PREPARATION. WHERE A DELEGATED DESIGN IS INDICATED ON THE DRAWINGS, THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR EACH ITEM, COMPONENT, AND CONNECTION NOT SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS. SHOP DRAWINGS AND DESIGN CALCULATIONS SHALL BE SIGNED AND SEALED BY THE CONTRACTOR'S LICENSED ENGINEER (IN THE PROJECT'S JURISDICTION). DRAWINGS AND CALCULATIONS SHALL SHOW LOCATIONS AND MAGNITUDES OF LOADS IMPOSED ON THE STRUCTURE. THE ENGINEER OF RECORD RESERVES THE RIGHT TO MODIFY LOAD PATH SUGGESTED BY THE DELEGATED DESIGN ENGINEER. SHOP DRAWINGS: SHOP DRAWING NOTES: CONTRACTOR SHALL FURNISH COMPLETE AND DETAILED SHOP DRAWINGS FOR THE FOLLOWING STRUCTURAL MATERIALS: STRUCTURAL STEEL REINFORCING STEEL CONCRETE MIX DESIGN COLD FORMED STEEL FRAMING UNLESS NOTED, SUBMIT SHOP DRAWINGS FOR ALL FABRICATED MATERIALS. ALL SHOP DRAWINGS MUST BEAR THE REVIEW STAMP OF THE GENERAL CONTRACTOR. UNSTAMPED SHOP DRAWINGS WILL BE REJECTED WITHOUT REVIEW. ELECTRONIC COPIES OF SHOP DRAWINGS SHALL BE SUBMITTED TO ENGINEER OF RECORD. ELECTRONIC COPIES OF SHOP DRAWINGS WILL ONLY BE ACCEPTED WITH THE APPROVAL OF THE ENGINEER OF RECORD. REPRODUCTION OF ELECTRONIC COPIES WILL BE BILLED TO GENERAL CONTRACTOR FOR REIMBURSEMENT OF PRINTING COSTS. DESIGN DRAWINGS SHALL NOT BE REPRODUCED FOR USE AS SHOP DRAWINGS. TWO SETS OF REVIEWED SHOP DRAWINGS WILL BE RETURNED TO THE GENERAL CONTRACTOR. ALLOW MINIMUM 10 WORKING DAYS FOR ARCHITECT/ENGINEER REVIEW OF EACH SHOP DRAWING SUBMITTAL. ALLOW AN ADDITIONAL WORKING DAY FOR EVERY 5 DRAWINGS OVER 30. SHOP DRAWINGS FOR CONSTRUCTION OF EACH BUILDING COMPONENT NOT DESIGNED BY THE DESIGN ENGINEER OF RECORD AND NOT SPECIFIED IN THE CONSTRUCTION DOCUMENTS SHALL BE SIGNED & SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT. COMPONENTS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: PRE ENGINEERED TRUSSES, RAILINGS, LADDERS, LIGHT GAUGE STUD FRAMING, RACK SYSTEMS, GLAZING SYSTEMS, AWNINGS AND ANY OTHER ITEM THAT IS DESIGNATED AS "DESIGNED BY OTHERS" OR "PRE ENGINEERED". THESE SHOP DRAWINGS SHALL BEAR CLEAR INDICATION THAT THEY HAVE BEEN REVIEWED AND APPROVED BY THE PROJECT ARCHITECT OR ENGINEER OF RECORD. SHOP DRAWINGS SUBMITTED TO THE ENGINEER OF RECORD SHALL ADHERE TO THE FOLLOWING GUIDELINES OR THEY WILL BE REJECTED AND RETURNED TO SENDER UNCHECKED: DETAILER SHALL COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ALL ATTACHMENTS, CLIPS, OPENINGS OR DUCTWORK AFFECTING STRUCTURAL MEMBERS. ALL ITEMS SHALL BE SHOWN ON SHOP DRAWINGS. DIMENSIONAL COORDINATION SHALL BE PERFORMED BY THE GENERAL CONTRACTOR AND/OR HIS FABRICATOR. PROPOSED CHANGES TO THE CONSTRUCTION DOCUMENTS SHALL BE CLEARLY MARKED IN THE SHOP DRAWINGS AND SHALL INCLUDE SIGNED & SEALED DRAWINGS AND CALCULATIONS BY AN ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. THE ENGINEER OF RECORD WILL REVIEW THE PROPOSED CHANGE FOR ACCEPTANCE. THE CONTRACTOR SHALL HAVE PROOF OF WELDER CERTIFICATION AT THE JOBSITE AT ALL TIMES. APPROVED SHOP DRAWINGS SHALL BE AVAILABLE AT THE JOBSITE AT ALL TIMES. THE LATEST ISSUE DATE, IN THE DRAWING REVISION BOX, OF ANY SHEET IN THE STRUCTURAL DRAWING SET, SHALL BE CLEARLY SHOWN ON THE TOP SHEET OF THE SHOP DRAWINGS. NO PARTIAL SETS WILL BE ACCEPTED, UNLESS PREVIOUSLY APPROVED BY THE ENGINEER OF RECORD. STEEL JOIST SUBMITTALS SHALL HAVE JOB SPECIFIC DETAILS IN ADDITION TO THE JOIST MANUFACTURER'S TYPICAL DETAILS. A. B. C. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 1 0 : 3 8 : 0 1 A M GEN. STRUCTURAL NOTES 2022020.40 FINAL DRAWINGS 01/20/2023 DMH JNK TYPE B REMODEL S0.02 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 G 2 1 1 F 2.1 2.5 EX. W8x10 EX. W8x10 2 3333 WT: 325# WT: 130# 4 5 4 5 6 6 7 8 S5.10 1 JOIST BEARING (+16'-2"± F.V.) 9 BCED A 3 1 F.V. 16' - 10" +/- +/- 15' - 6 3/8" F.V. F.V. 18' - 6" +/- F.V. 13' - 10" +/- F.V. 18' - 6" +/- F.V. 15' - 11 1/2" +/- F .V . 1 ' - 1 0 " +/- F .V . 8 ' - 1 7 /8 " +/- F .V . 2 4 ' - 0 " +/- F .V . 1 5 ' - 1 1 1 /8 " +/- EX. W16x26 (+17'-2 1/2"± F.V.) EX. W14x22 (+17'-2 1/2"± F.V.) EX. W16x26 (+17'-2 1/2"± F.V.) 5' - 1 1/2"5' - 1 1/2"6' - 9 5/8"6' - 4"6' - 9 5/8"6' - 9 5/8"6' - 4"6' - 9 5/8"6' - 9 5/8"6' - 4"6' - 9 5/8"6' - 9 5/8"6' - 9 5/8"6' - 11"4' - 5 1/2"4' - 1 3/8"5' - 4 1/8" F.V. 99' - 1 7/8" +/- EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H EX . 3 6 L H (2 8 2 / 1 7 9 ) (3 2 8 / 2 0 9 ) (3 6 1 / 2 3 0 ) (3 6 1 / 2 3 0 ) (3 7 4 / 2 3 8 ) (3 6 1 / 2 3 0 ) (3 6 1 / 2 3 0 ) (3 7 4 / 2 3 8 ) (3 6 1 / 2 3 0 ) (3 6 1 / 2 3 0 ) (3 7 4 / 2 3 8 ) (3 7 4 / 2 3 8 ) (3 7 7 / 2 4 0 ) (3 1 3 / 1 9 9 ) (2 3 6 / 1 5 0 ) SKYLIGHT SKYLIGHT SKYLIGHT SKYLIGHT SKYLIGHT SKYLIGHT SKYLIGHT EX . 1 8 L H EX . 1 8 L H EX . 1 8 L H (2 6 0 / 1 6 6 ) 1. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE JOB CONDITIONS AND RESTRICTIONS. 2. EXISTING ROOF CONSTRUCTION, JOISTS, & JOIST SPACING IS BASED ON EXISTING STRUCTURAL PROTOTYPE DRAWINGS. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ALL EXISTING CONSTRUCTION CONDITIONS PRIOR TO ORDERING MATERIALS AND COORDINATE ANY DISCREPANCIES WITH THE E.O.R. 3. VERIFY ALL ROOF OPENING SIZES AND LOCATIONS FOR MECHANICAL EQUIPMENT WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. 4. DO NOT SCALE DRAWINGS. 5. GENERAL CONTRACTOR AND SUB-CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. 6. FOR DIMENSIONS NOT SHOWN, SEE ARCHITECTURAL DRAWINGS. 7. SEE SHEETS S0.01 AND S0.02 FOR GENERAL STRUCTURAL NOTES. 8. SEE MECHANICAL DRAWINGS FOR SIZES AND LOCATIONS FOR ALL MECHANICAL EQUIPMENT. INDICATES METAL ROOF DECK DENOTES TOP OF STEEL ELEVATION ABOVE FINISH FLOOR ELEVATION. (+/-x'-x") INDICATES LH-SERIES JOIST WITH (DL+LL LOAD/LIVE LOAD)_LH (**/**) PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 1 0 : 3 8 : 0 2 A M ROOF FRAMING PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 DMH JNK TYPE B REMODEL S1.11 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 ROOF FRAMING PLAN KEYED NOTES GENERAL NOTESSYMBOL LEGEND 1 EXISTING 1.5" METAL DECK 2 EXISTING LT. GAUGE EXTERIOR WALL. 3 EXISTING STEEL COLUMN. 4 MC6x15.3 LAID FLAT WITH FLANGES TURNED DOWN BETWEEN THE DECK FLUTES TO SUPPORT MECHANICAL UNIT CURB. EXTEND MC6 CHANNEL 6" MIN. PAST BEARING END. SEE DETAIL 7/S5.10. 5 C6x8.2 LAID FLAT BENEATH ROOF CURB. 6 NEW CONDENSER PER MECHANICAL. SEE 7/S5.10 FOR SUPPORT DETAILS. 7 NEW TV. SEE 2/S5.10 FOR TV SUPPORT DETAILS. SEE ARCH'L DRAWINGS FOR LOCATION. 8 WALL FRAMING BELOW. 9 EXISTING ROOFTOP CONDENSING UNIT N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 NOTE: ALL METAL STUDS ARE 3 5/8"x20 GAUGE (362S137-33) AT 16" O.C. ATTACH NEW TRACK TO SOFFIT w/(2)-#10 SCREWS @ 16" O.C. SOFFIT FRAMING EX. METAL DECK PER PLAN (2)-#10 STS L3x3x1/4 BETWEEN HEADERS STEEL ANGLE, SEE PLAN. L3x3x1/4 BETWEEN JOISTS @ MAX 8'-0" O.C. 3/16 TYP. EA. END EX. STEEL JOIST PER PLAN 3/16 MC12 (3) SIDES OF CANOPY 362S137-33 @ 16" O.C. 362T137-33 @ 16" O.C. w/(1)-# 10 SCREW AT EACH LEG BRIDGING CENTERED ON STUD LB362 STIFF CLIP WITH (3)-#12 STS INTO STUD AND (2) 3/16" DIA. P.A.F. INTO ANGLE SEE PLAN 3/16 3-12 CONT. L3x3x1/4 2"x2"x16 GAUGE CLIP AT EA. STUD TO ANGLE w/(2)-#10 SCREWS EA. LEG. 3/16 4 S5.10 MC12x10.6 (T/STL=10'-0") HSS3 1/2x3 1/2x5/16 HANGER 5 S5.10 HSS3 1/2x3 1/2x5/16 HANGER C E N T E R L I N E H A N G E R /C H A N N E L 1 6 ' - 3 " E Q E Q E Q E Q MC12x10.6 (T/STL=10'-0") MC 1 2 x 1 0 . 6 (T / S T L = 1 0 ' - 0 " ) L2x2x1/4 AT QUARTER POINTS w/(2) #10 STS SCREWS TO STUDS RO O F J O I S T AB O V E RO O F J O I S T AB O V E RO O F J O I S T AB O V E EXISTING SOFFIT L3x3 (HIGH) BETWEEN JOIST TOP CHORD, TYP. L5x3x3/8 LLV (AT BOT. CHORD) L5x3x3/8 LLV (AT BOT. CHORD) L5x3x3/8 LLV (AT BOT. CHORD) L3x3 (LOW) BETWEEN JOIST BOT CHORD, TYP. L3x3 HEADER ANGLE (HIGH) L3x3 HEADER ANGLE (HIGH) 3' - 4" F.V. 5' - 1 5/8" +/- 3/8" STEEL PLATE WITH 1 1/2" RADIUS CORNERS, EACH END 3/8" DIA. ROD STEEL HANGER, SEE PLAN 3/16 1/4 1/4 L3x3x1/4 BETWEEN JOISTS PROVIDE JOIST REINFORCING PER DETAIL 6/S5.10 WHERE HANGER IS LOCATED BETWEEN PANEL POINTS EX. METAL DECK PER PLAN EX. STEEL JOIST PER PLAN #2 CLEVIS, EACH END 3/16 CHANNEL TO TUBE SEE PLAN MC12 (3) SIDES OF CANOPY SHEAR TAB (TYP.) SEE 3/S5.10 3/16 3/16 TYP. EA. END L5x3 (LLV) SEE PLAN 5" CONCRETE SLAB ON GRADE WITH #4 BARS @ 18" O.C. EACH WAY ON 10 MIL VAPOR RETARDER ON 8" COMPACTED #57 STONE. PROVIDE MIN. 6" LAP w/EX. VAPOR RETARDER. TAPE SEAMS SAW CUT LINEEX. CONC. SLAB NEW SLAB TO BE LEVEL AND FLUSH WITH ADJACENT SLAB #4x0'-8" DOWEL @ 12" O.C. w/HILTI HIT-HY 200 V3 SAFESET ADHESIVE (4" EMBED.) UTILITY TRENCH SLAB INVESTIGATION NOTE: 1. THE EXISTING SLAB CONSTRUCTION IS ASSUMED TO BE SLAB-ON-GRADE. DUE TO THE LIMITED FOUNDATION INFORMATION, THE OWNER SHALL RETAIN THE SERVICES OF A TESTING AGENCY TO FIELD VERIFY THE EXISTING SHALLOW FOUNDATION AND SLAB-ON-GRADE CONSTRUCTION PRIOR TO TRENCHING EXISTING SLAB AND ORDERING MATERIALS. 2. IF STRUCTURAL SLAB AND GRADE BEAM FOUNDATION SYSTEM ARE FOUND, GROUND PENETRATING RADAR (GPR) SHALL BE UTILIZED FOR MAPPING OUT THE LOCATION OF GRADE BEAMS AND SLAB REINFORCING. THE SLAB SHALL BE CORED DRILLED TO VERIFY SLAB THICKNESS. LOCATIONS FOR CORE DRILLING SHALL BE REVIEWED BY E.O.R. PRIOR TO BEGINNING ANY WORK. DATA FROM MAPPING AND CORE DRILLING SHALL BE PROVIDED TO GPD GROUP FOR REVIEW PRIOR TO ORDERING AND/OR FABRICATING OF MATERIALS FOR THE WORK. REVISED DETAILS AND PLANS WILL BE REQUIRED IF STRUCTURAL SLAB IS FOUND. 3. THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY IF THE FOUNDATION AND/OR SLAB CONSTRUCTION ARE DETERMINED TO BE SOMETHING OTHER THAN WHAT IS ASSUMED. SHEAR TAB SHALL BE 3/8" THICK. 5/16" FILLET WELD EACH SIDE OF SHEAR TAB. BOLT SPACING SHALL BE 3" TYP. HSS COLUMN SHALL HAVE A MINIMUM 1/4" THICKNESS. USE A SINGLE ANGLE CONNECTION WHERE STEEL TUBE WALL IS TOO THIN. BOLT EDGE DISTANCE, SHALL BE EQUAL TO TWICE THE BOLT DIAMETER FOR BOTH THE PLATE AND THE BEAM WEB. BOLT EDGE DISTANCE, SHALL BE 1-1/4" FOR BOLT DIAMETERS 7/8" OR LESS AND 1-3/4" FOR BOLT DIAMETERS GREATER THAN 7/8". ANGLE SIZE SHALL BE 3" FOR SHORT LEG AND 4 TIMES THE BOLT DIAMETER +1" FOR THE LONG LEG. "a" "b" "c" "e" "f" "g" A325 BOLT SCHEDULE MAXIMUM BEAM SIZE IN EACH BEAM DEPTH GROUP A-325N BOLTS No. PER BEAM SIZE MC12 3 3/4" DIA. 3" TRIM LEG IF WIDER THAN COLUMN STEEL COLUMN ANGLE "g" SEE NOTE "a" FOR THICKNESS 5/16 OR 5/16 3/4 5/16 SINGLE ANGLE CONNECTION WHERE REQUIRED BY NOTE "e" STEEL BEAM STEEL COLUMN SEE NOTE "e" TYP. 3/4" SHEAR TAB "a" "b" TYP. T Y P . "f " T Y P . "c " "f" "f" NOTE: THIS DETAIL IS INTENDED TO BE USED WHERE LOADS OCCUR AT LOCATIONS OTHER THAN AT JOIST CHORD PANEL POINT LOCATIONS. NOTE: WHEN A CONCENTRATED LOAD OCCURS BETWEEN CHORD PANEL POINTS, PROVIDE ANGLE REINFORCEMENT AS SHOWN IF THE APPLIED LOAD EXCEEDS 100#. IF MULTIPLE CONCENTRATED LOADS OCCUR BETWEEN CHORD PANEL POINTS, THE SUM OF THE CONCENTRATED LOADS SHALL NOT EXCEED 100# L2x2x1/4 ANGLE STRUT AT JOISTS - PROVIDE ONE ANGLE ON EACH SIDE OF JOIST LOAD 3/16 3 SIDES EA. END PANEL POINT LOAD L2x2x1/4 EA. SIDE STEEL SHIMS @ 2'-0" O.C. (NOT REQ'D IF TAPERED CURBS ARE PROVIDED) 3/16 3 SIDES EA. END NOTE: WHEN A CONCENTRATED LOAD OCCURS BETWEEN CHORD PANEL POINTS, PROVIDE ANGLE REINFORCEMENT AS SHOWN IF THE APPLIED LOAD EXCEEDS 100 LBS. IF MULTIPLE CONCENTRATED LOADS OCCUR BETWEEN CHORD PANEL POINTS, THE SUM OF THE CONCENTRATED LOADS SHALL NOT EXCEED 100 LBS. C6 ALIGN w/CURB 1/4 MECH. UNIT MECH. UNIT CURB SEE MECH'L DWGS CONT. MC6 12 GAUGE STRAP w/(3)-# 12 SCREWS EA. END 1/2" DIA. SMOOTH DOWEL 18" LONG AT 12" O.C. - APPLY BOND BREAKER OR VISQUEEN WRAP TO FREE END CONSTRUCTION JOINT CONTROL JOINT VAPOR RETARDERCONC. SLAB, SEE PLAN CLEAN HARDENED CONCRETE AND APPLY BOND BREAKER PRIOR TO PLACING 2ND POUR 1/8" SAWCUT CONTROL JOINT TO BE 1/4 SLAB THICKNESS FILL SAW CUT w/JOINT SEALANT CONC. SLAB, SEE PLAN VAPOR RETARDER GRANULAR FILL (2)-#4 x 4'-0" LG. BARS WHERE CONTROL/CONSTRUCTION JOINTS INTERSECT BUT DO NOT CONTINUE BEYOND INTERSECTION CONTROL OR CONSTRUCTION JOINT CONTROL OR CONSTRUCTION JOINTS (2)-#4 x 4'-0" LG. BARS AT EACH CORNER OF DEPRESSED SLAB OR RE-ENTRANT CORNER WHERE CONTROL/CONSTRUCTION JOINTS DO NOT EXTEND FROM CORNER DEPRESSED CONCRETE SLAB OR RE-ENTRANT CORNER METAL ROOF DECK EXISTING JOIST HSS4x4x3/16 WITH 1/8" CLOSURE PLATE EA. END 1/4 4 '-0 " M A X . HOUSING BOX(2)L3x3x1/4x0'-3" WITH 3/4" DIA. THREADED ROD AT EACH END, BOLTED TO THE JOIST BOTTOM CHORD 3/4" DIA. HOLE THROUGH TOP AND BOTTOM OF HSS FOR ELECTRICAL ACCESS 3" DIA. STD PIPE MITER TUBE AT TOP AS REQUIRED FOR ROOF SLOPE CENTER ON TUBE ABV A A SECTION A-A 1/4 TYP. 3 SIDES WHERE TUBE FALLS BETWEEN PANEL POINTS INSTALL JOIST REINFORCING PER DETAIL 6/S5.10 JOIST BOTTOM CHORD PLATE WASHER PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 1 0 : 3 8 : 0 5 A M FOUNDATION & FRAMING DETAILS 2022020.40 FINAL DRAWINGS 01/20/2023 DMH JNK TYPE B REMODEL S5.10 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:3/4" = 1'-0"4 SECTION SCALE:1/4" = 1'-0"1 BON-FIRE GRILL CANOPY PLAN SCALE:3/4" = 1'-0"5 SECTION SCALE:3/4" = 1'-0"10 SECTION SCALE:3/4" = 1'-0"3 TYP. BOLTED SHEAR TAB CONN. SCHEDULE SCALE:3/4" = 1'-0"6 TYP. JOIST REINFORCING SCALE:3/4" = 1'-0"7 CONDENSER SUPPORT DETAIL SCALE:3/4" = 1'-0"8 TYP. FLOOR SLAB JOINT DETAILS SCALE:3/4" = 1'-0"9 TYP. RE-ENTRANT CORNER BAR DETAIL SCALE:3/4" = 1'-0"2 TYP. TV MOUNT DETAIL N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 PLUMBING GENERAL NOTES 1. SLOPE BUILDING SANITARY WASTE LINES IN THE BUILDING AT 1/4”PER FOOT. THE P.C. MAY RUN 4”AND LARGER AT 1/8”PER FOOT IF PERMITTED BY THE AUTHORITY HAVING JURISDICTION. FIELD VERIFY EXTERIOR BUILDING SEWER INVERT PRIOR TO INSTALLATION OF INTERIOR PIPING. 2. PROVIDE WALL & FLOOR CLEANOUTS PER CODE REQUIREMENTS WITH (WALL) S.S. OR BRASS C.O. WALL COVERS, BRASS SCREWS, AND FLUSH WITH FINISHED WALL. SEE DETAIL 3/P2.02. 3. HANG ALL VENT PIPING AS SHOWN, WITH CLEVIS HANGERS, ALL THREAD ROD AND SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL WITH CLAMPS. KEEP PIPING AS TIGHT AS POSSIBLE TO THE TRUSSES TO ENSURE NO OBSTRUCTIONS WITH OTHER TRADES, AND RAIN WATER LEADER/ROOF DRAIN PIPING. 4. PROVIDE DEEP SEAL P-TRAP AND TRAP PRIMER OR TRAP GUARD ON ALL FLOOR DRAINS/SINKS. TRAP SEAL DEVICE: J.R. SMITH 2692 OR PROSET TRAP GUARDS. INSTALL 1/2”SOFT “K”COPPER OR ENGLES METHOD PEX PIPE, ENCASED IN PLASTIC PIPE SLEEVE, TO EACH FLOOR DRAIN/SINK. TRAP SEAL DEVICES: NO PIPING REQUIRED. SEE DETAIL. 5. ALL FLOOR DRAINS/SINKS SHALL HAVE INDIVIDUAL P-TRAP AND SHALL BE VENTED BY THE BUILDING SANITARY VENT SYSTEM. 6. SEE CONVENIENCE STORE EQUIPMENT SCHEDULE ON SHEET P2.00 FOR KITCHEN EQUIPMENT INDIRECT WASTE REQUIREMENTS. PLUMBING CONTRACTOR SHALL ROUTE ALL KITCHEN EQUIPMENT, ICE BINS, AND OTHER EQUIPMENT INDIRECT WASTE LINES WITH AIR GAP TO NEAREST FLOOR SINK. COORDINATE ALL KITCHEN EQUIPMENT DRAINS WITH K.E. SUPPLIER AND INSTALLER. 7. ALL ICE MAKER AND ICE STORAGE BINS DRAIN LINES SHALL BE A MINIMUM OF 3/4”. NO EXCEPTIONS. 8. THE PLUMBING CONTRACTOR SHALL PROVIDE A FULL SIZE DRAIN ON ALL BACKFLOW PREVENTION DEVICES. ROUTE FULL SIZE DRAIN TO AN APPROVED DISCHARGE RECEPTOR, AND INSTALL WITH CODE COMPLIANT AIR GAP. 9. THE PLUMBING CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL FLOOR DRAIN, FLOOR SINKS, AND TRAP PRIMERS. SEE ARCHITECTURAL SHEETS FOR DIMENSIONS AND EXACT LOCATIONS. CONTRACTOR SHALL CONTACT THE ARCHITECT IMMEDIATELY IF DISCREPANCIES EXIST. 10. CONNECT SEWER VENT PIPING AND ROUTE HORIZONTALLY WITHIN BUILDING. PENETRATE BUILDING WITH FULL SIZE VENT THROUGH ROOF WHERE SHOWN. INSTALL VTRS HEIGHT OF BUILDING PARAPET. SECURE ALL VENT PIPING. 11. HANG ALL VENT PIPING, AS SHOWN, WITH CLEVIS HANGERS, ALL THREADED ROD AND SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL WITH CLAMPS. KEEP PIPING AS TIGHT AS POSSIBLE TO THE TRUSSES TO PROVIDE ROOM FOR OTHER TRADES, ROOF DRAINS AND STORM DRAIN PIPING. 12. PLUMBING CONTRACTOR SHALL PROVIDE PIPE TAG WITH EQUIPMENT NAME, FUNCTION AND BTUH LOAD. 13. PROVIDE TRUE-BRO INSULATION ITS, ON ALL SINKS WITH EXPOSED DRAINS AND SHUTOFF VALVES. 14. SEE THE KITCHEN EQUIPMENT SHEETS FOR REQUIREMENTS AND INSTALLATION HEIGHTS. EQUIPMENT IS OWNER FURNISHED, VENDOR INSTALLED. PLUMBING CONTRACTOR SHALL PROVIDE AND CONNECT WASTE, VENT AND WATER CONNECTIONS AND ALL ASSOCIATED MATERIALS. 15. MINIMUM CONDENSATE PIPING IS 3/4”. SEE PIPE SPECIFICATIONS FOR MATERIALS. 16. INDIRECT WASTE TO SINKS MAY BE PVC-DWV IF PERMITTED BY LOCAL CODE AND THE WATER SUPPLY TEMPERATURE TO SINKS IS 120°F OR LESS. IF WATER SUPPLY TEMPERATURE IS GREATER THAN 120°F, USE HARD DRAWN 'L' COPPER PIPE WITH WROUGHT FITTINGS. 17. ALL FLOOR DRAINS SHALL BE FLUSH WITH FINISHED FLOOR. 18. CABINETS CONTAINING FLOOR SINK SHALL BE OPEN TO THE FLOOR SINK FOR CLEANING AND ACCESS. 19. MAINTAIN CODE COMPLIANT SEPARATION BETWEEN SANITARY WASTES AND FOOD SERVICE WASTES. 20. ALL VENTS IN EXTERIOR WALLS SHALL BE INSTALLED ON THE WARM SIDE OF BUILDING INSULATION. 21. ALL UNDER FLOOR WATER PIPING SHALL BE WRAPPED IN MINIMUM OF 1/2”THICK ARMAFLEX INSULATION, OR AS REQUIRED PER LOCAL CODE, UNLESS PIPING IS LOCATED WITHIN A PIPE CHASE OR UNDERSLAB SLEEVE. 22. SEE PLUMBING PLANS FOR EXACT LOCATION OF ROOF DRAINS AND VENT PIPING THROUGH ROOF. 23. ALL GAS PIPING SHALL BE INSTALLED IN COMPLIANCE WITH ALL LOCAL CODES AND NFPA REQUIREMENTS. PROVIDE PERMITS, MATERIALS AND LABOR FOR A COMPLETE, FUNCTIONAL PIPING SYSTEM. PERFORM ALL TESTS TO MEET THESE CODES. 24. PLUMBING CONTRACTOR SHALL CONFIRM LOCATION OF ALL EQUIPMENT PRIOR TO PROVIDING PLUMBING ROUGH-IN. 25. ANY PENETRATIONS THROUGH FIRE RATED PARTITIONS SHALL BE SEALED WITH SCOTCH-3M #FS 195 WRAP AND CP #25 CAULK. 26. PLUMBING CONTRACTOR SHALL NOT INSTALL PIPING ABOVE OR WITHIN THE CODE REQUIRED WORKING CLEARANCES OF AN ELECTRICAL PANEL, SWITCH GEAR, OR CONDUITS. COORDINATE ALL WORK WITH THE ELECTRICAL CONTRACTOR. 27. THE PLUMBING CONTRACTOR SHALL MAKE ALL REQUIRED FINAL PLUMBING CONNECTIONS TO OWNER SUPPLIED EQUIPMENT. 28. VENTS OFFSETTING HORIZONTALLY MUST BE AT LEAST 6”ABOVE THE HIGHEST FIXTURE’S FLOOD RIM. 29. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL ‘P’PLUMBING FIXTURES AND EQUIPMENT SHOWN ON THE PLUMBING FIXTURE SCHEDULE. OWNER FURNISHED ITEMS SHALL BE CONNECTED TO BUILDING WASTE AND WATER SYSTEMS BY THE PLUMBING CONTRACTOR. 30. ONLY FULL PORT BALL VALVES ARE PERMITTED AND SHALL BE USED FOR ZONE OR AREA VALVES WITHIN THE BUILDING. 37. ALL HOT WATER, COLD WATER, ROOF DRAIN, OVERFLOW DRAIN, AND CONDENSATE PIPING WILL BE INSULATED WITH MINIMUM 1”THICK INSULATION. SEE INSULATION SCHEDULE IN THESE PLANS FOR INSULATION TYPE AND THICKNESS. 38. ALL WATER LINES SHALL BE HUNG USING COATED CLEVIS HANGERS, ALL THREAD ROD AND SIDE BEAM ATTACHMENTS OR EPOXY COATED UNISTRUT CHANNEL, ALL THREAD ROD AND SIDE BEAM ATTACHMENTS, SECURE PIPE WITH INSULATED CLAMPS. 39. ALL KITCHEN EQUIPMENT, OWNER PROVIDED EQUIPMENT, AND BAR SINKS INDIRECT WASTE DRAINS SHALL BE PIPED TO A FLOOR SINK W/PROPER AIR GAP. PROVIDE CLEAN OUT ACCESS TO THESE FLOOR SINKS LOCATED UNDER CABINETS. 40. INSTALL WATER BALL VALVE SHUT OFF VALVES TO ALL OWNER PROVIDED KITCHEN AND BEVERAGE EQUIPMENT. VALVES SHALL BE PARKER HANNIFIN, APOLLO FERGUSON OR NIBCO. MAY BE SUBSTITUTED WITH 10-DAY PRIOR APPROVAL BY OWNER AND ENGINEER. THESE VALVES SHALL BE LOCATED PER EQUIPMENT MANUFACTURERS RECOMMENDATION OR OWNERS DIRECTION. PROVIDE AND INSTALL ALL BACKFLOW PREVENTION AS REQUIRED PER STATE AND LOCAL PLUMBING CODES. 41. SEE SHEET P2.00, PLUMBING FIXTURE SCHEDULE FOR A LISTING OF ALL OF THE PLUMBING FIXTURES AND EACH FIXTURE’S TRIM. 42. ANY & ALL PENETRATIONS THROUGH THE BUILDING ROOF OR WALLS SHALL BE SEALED WITH “DECK-MATE”FLASHING FOR ROOF & WALL SYSTEMS. G.C. SHALL PROVIDE, INSTALL & PAINT TO MATCH BUILDING. PLUMBING CONTRACTOR SHALL COORDINATE WITH THE G.C. ALL PENETRATIONS AND SIZES. THE ARCHITECT SHALL HAVE THE FINAL INPUT ON HOW ALL PENETRATIONS SHALL BE SEALED. THE PLUMBING CONTRACTOR AND G.C. SHALL VERIFY WITH THE ARCHITECT ALL SEALING REQUIREMENTS. 43. THE PLUMBING CONTRACTOR SHALL PROVIDE A PERMANENTLY SECURED LAMINATED VALVE TAG (PRIOR TO FINAL WALK THRU), TO EACH OF THE COLD AND HOT WATER VALVES WHICH SERVE THE MAVERIK’S EQUIPMENT. 44. ALL WATER VALVES ABOVE HARD LID OR DROP-IN CEILING SHALL BE INSTALLED BETWEEN 1’-0”TO 1’-6”ABOVE THE CEILING FOR ACCESS VIA LADDER BY MAINTENANCE PERSONNEL. PROVIDE BIG ENOUGH ACCESS PANEL TO ACCESS EACH VALVE AT EACH LOCATION. 45. THE PLUMBING CONTRACTOR SHALL MEET ALL STATE, LOCAL AND HEALTH DEPARTMENT CODES RELATED TO BACKFLOW PROTECTION. EACH PIECE OF EQUIPMENT THAT IS PROVIDED BY THE P.C. AND THE OWNER SHALL HAVE THE PROPER BACKFLOW PREVENTION. FIELD VERIFY WITH STATE, CITY AND HEALTH DEPARTMENT BACKFLOW PROTECTION REQUIREMENTS FOR THE STORE AND EACH PIECE OF EQUIPMENT BEING INSTALLED. THE P.C. IS RESPONSIBLE TO PROVIDE ALL NECESSARY BACKFLOW PREVENTION DEVICES FOR EACH EQUIPMENT PIECE. PROVIDE FULL SIZE DRAINS TO AN APPROVED RECEPTOR WITH CODE COMPLIANT AIR GAP. PLUMBING GENERAL NOTES 1. DOMESTIC WATER: PEX PIPING MAY BE INSTALLED IN ALL CONCEALED SPACES, ABOVE CEILING, AND IN BETWEEN WALLS IF APPROVED BY THE LOCAL PLUMBING CODE. THE P.C. SHALL USE THE FOLLOWING: PEX PIPE:UPONOR -PAX a (ENGLE-METHOD CROSSLINKED POLYETHYLENE). ASTM 876/877. FITTINGS:UPONOR -PROPEX ENGINEERED POLYMER (EP) FITTINGS. ASTM 1960 AND ANSI/NSF 14 & ANSI/NSF 61. CONNECTOR:UPONOR -PROPEX RINGS (ENGLE-METHOD CROSSLONKED POLYETHYLENE). ANSI/NSF 14 & ANSI/NSF 61. SUPPORTS:UPONOR -PAX a PIPE SUPPORT (CHANNEL). GALVANIZED STEEL CHANNGEL. FOR ASTME 84 INSTALLATIONS. ALL PIPE MUST BE COVERED WITH A PEX a PIPE SUPPORT OR A MINIMUM 1/2" THICK RATED INSULATION. REFER TO UPONOR INSTALLATION INSTRUCTIONS. "ALL EXPOSED PIPING SHALL BE TYPE "L" COPPER WITH WROUGHT FITTINGS." (NO SUBSTITUTIONS) : WRONG MATERIALS WILL BE REMOVED AND REPLACED AT THE PLUMBING CONTRACTORS EXPENSE. PEX PIPE ALTERNATE SPECIFICATIONS PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 3 : 4 8 P M PLUMBING LEGENDS & NOTES 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL P0.00 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 NG(LP)LOW PRESSURE NATURAL GA... HB HOSE BIBB FPSC FROSTPROOF SILLCOCK AD ACCESS DOOR AFF ABOVE FINISHED FLOOR HD HUB DRAIN BFP BACKFLOW PREVENTER KEC KITCHEN EQUIPMENT... FS FLOOR SINK VTR VENT THRU ROOF SH SHOWER FD FLOOR DRAIN CO CLEANOUT COTG CLEANOUT TO GRADE FCO FLUSH WITH FLOOR CLEANOUT EWC ELECTRIC WATER COOLER MS MOP SINK S SINK LAV LAVATORY UR URINAL WC WATER CLOSET CD CONDENSATE DRAIN PIPING CA COMPRESSED AIR PIPNG FP FIRE PROTECTION PIPING NG NATURAL GAS PIPING HWR HOT WATER RETURN PIPING HW HOT WATER PIPING CW COLD WATER PIPING OFD OVERFLOW ROOF DRAIN... RD ROOF DRAIN PIPING V SANITARY VENT PIPING GW GREASE WASTE SAN SANITARY PIPING PLUMBING ABBREVIATIONS THIS PROJECT CONSISTS OF AN EXISTING CONVENIENCE STORE REFRESH OF STORE FIXTURES AND STORE EQUIPMENT. THERE WILL BE SEVERAL NEW WALLS INSTALLED TO FACILITATE THE REFRESH. THE EXISTING DRINK STATION AREA IS BEING RECONFIGURED. THE NEW DRINK EQUIPMENT WILL REQUIRE NEW INDIRECT WASTES TO THE NEW DRINK STATION FLOOR SINK. THE NEW DUMP SINK WILL HAVE AN INDIRECT WASTE DRAINING TO THE NEW FLOOR SINK, AND IT WILL CONNECT TO ADJACENT HOT AND COLD WATER BRANCHES. THERE ARE NEW DUMP SINKS LOCATED ON A NEW WALL, THEY WILL INDIRECTLY WASTE INTO A NEW FLOOR SINK AND THEY WILL CONNECT TO EXISTING ADJACENT HOT AND COLD WATER BRANCHES. THE EXISTING COFFEE AREA WILL BE SHORTENED, WITH AN EXISTING WING WALL REMOVED. THERE WILL BE NEW CABINETRY, COUNTER AND NEW EQUIPMENT. COFFEE AREA PLUMBING WILL BE MODIFIED TO ACCOMMODATE THE NEW LAYOUT, AND NEW FLOOR SINKS AND DUMP SINK WILL BE INSTALLED. CONTRACTOR WILL PROVIDE NEW CONNECTIONS TO EXISTING WATER, WASTE AND VENT BRANCH MAINS. PLUMBING DESIGN INTENT GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 G 2 F 2.1 2.5 8 BCED A 3 3 4 5 2 6 7 1 (E)FS-1 (E)FS-1 (E)FS-1 (E)FS-1 (E)FS-1 (E)FS-1 1 (E)FS-1 1 (E)FS-1 1 (E)FS-1 (E)FS-1 (E)FS-1 1 1 1 (E)FS-1 1 2 2 2 3 4 4 5 6 6 7 7 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 3 : 5 1 P M PLUMBING DEMOLITION PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL P0.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 KEY NOTES SCALE:1/4" = 1'-0"1 PLUMBING DEMOLITION PLAN 1 EXISTING FLOOR SINK TO REMAIN. RETAIN SANITARY VENT CONNECTIONS. 2 EXISTING FLOOR SINK TO BE REMOVED. CUT AND CAP WASTE AND VENT BELOW FLOOR. 3 RETAIN BEVERAGE CONDUIT. MODIFY AS REQUIRED TO ACCOMMODATE NEW CABINETS. 4 RETAIN EXISTING BEVERAGE CONDUIT. 5 CUT AND CAP EXISTING BEVERAGE CONDUIT BELOW FLOOR. 6 RETAIN CONDUIT. SEE P1.01 FOR CONTINUATION. 7 EXISTING GREASE WASTE TO REMAIN. JET AND SCOPE ALL EXISTING PIPING BEING MODIFIED TO ENSURE NO OBSTRUCTIONS. NOTIFY OWNER IF DAMAGED OR OBSTRUCTED. 8 EXISTING SANITARY WASTE TO REMAIN. JET AND SCOPE ALL EXISTING PIPING BEING MODIFIED TO ENSURE NO OBSTRUCTIONS. NOTIFY OWNER IF DAMAGED OR OBSTRUCTED. GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 G 2 F 2.1 2.5 8 BCED A 3 2 1 3 4 5P7 P7 P7P7 6 9 10 11 FS-1 5151 51 95 74 74 73 734 115 115 115 69 51 FS-1 (E)FD-1 (E)FD-1 (E)FS-1 (E)FS-1 (E)FS-1 (E)FD-1 (E)FD-1 (E)FS-1(E)FS-1 (E)FS-1 (E)FD-1(E)FD-1 (E)FS-1 (E)FS-1 1 1 2 3 3 3 4 (E)FS-1 5 55 6 6 7 7 8 11 11 9 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 3 : 5 6 P M PLUMBING WASTE AND VENT PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL P1.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 PLUMBING WASTE AND VENT PLAN KEY NOTES 1 EXTEND 4" PVC CONDUIT TO NEW GONDOLA. COORDINATE WITH ARCHITECTURAL FOR PENETRATION. 2 CONNECT NEW 3" FS-1 TO EXISTING 3" MINIMUM GREASE WASTE MAIN. ROUTE 1-1/2" VENT UP AND CONNECT TO EXISTING VENT. 3 MODIFY EXISTING FLOOR SINK CONNECTIONS IF NEEDED TO ACCOMMODATE NEW CABINETRY. 4 CONTRACTOR SHALL REWORK EXISTING SODA CONDUIT SO IT IS ENCLOSED WITHIN NEW CABINETRY. COORDINATE WITH EXISTING CONDITIONS. 5 ROUTE 1-1/2" INDIRECT WASTE FROM DUMP SINK TO FLOOR SINK BELOW. SEE INDIRECT WASTE PIPING DETAILS FOR ADDITIONAL INFROMATION. 6 EXISTING GREASE WASTE TO REMAIN. JET AND SCOPE ALL EXISTING PIPING BEING MODIFIED TO ENSURE NO OBSTRUCTIONS. NOTIFY OWNER IF DAMAGED OR OBSTRUCTED. 7 TIE NEW VENT INTO EXISTING VENT MAIN. FIELD VERIFY EXACT LOCATION AND HEIGHT OF EXISTING VENT MAIN PRIOR TO THE START OF ANY WORK. 8 EXISTING SANITARY WASTE TO REMAIN. JET AND SCOPE ALL EXISTING PIPING BEING MODIFIED TO ENSURE NO OBSTRUCTIONS. NOTIFY OWNER IF DAMAGED OR OBSTRUCTED. 9 PROVIDE INDIRECT DRAIN FROM COLD PAN TO FLOOR SINK WITH CODE APPROVED AIR GAP. GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 10 CONTRACTOR SHALL RE-ROUTE OR ADJUST THE CONDENSATE PIPING AS NEEDED TO ACCOMMODATE THE NEW ROLLING RACK SHELVING. ENSURE THAT THE WORK IS PERFORMED SUCH THAT THE MINIMUM 1/4" PER FOOT IS MAINTAINED AND NO TRAPS ARE CREATED. 11 PROVIDE INDIRECT DRAIN FROM BEAN TO CUP MACHINE TO FLOOR SINK WITH CODE APPROVED AIR GAP. 01/20/23 G 2 F 2.1 2.5 BCED A 3 1 3 4 5 7 3 3 62 P7 P7 P7P7 51 5151 1 8 9 8 51 69 115 115 115 4 737374742118 95 11 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 3 : 5 9 P M PLUMBING WATER PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL P1.02 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 PLUMBING WATER PLAN KEY NOTES 1 ROUTE NEW 1/2" FW IN CASEWORK FROM EXISTING FILTERED COLD WATER PIPING AND STUB OUT AT 18" A.F.F. AND PIPE TO CAPPUCCINO MACHINE ON THE COUNTERTOP. PROVIDE CODE COMPLIANT BACKFLOW PREVENTER AS SCHEDULED ON SHEET P2.00. 2 ROUTE NEW 1/2" FW-1 DOWN IN WALL. ROUTE TO F'REAL MACHINE, PROVIDE CODE COMPLIANT BACKFLOW PREVENTER AS SCHEDULED ON SHEET P2.00. 3 CONNECT 1/2" HW & 1/2" CW TO SINK PROVIDE WITH ISOLATION SHUTOFF VALVES LOCATED ABOVE FIXTURE, IN CEILING ABOVE. 4 RETAIN EXISTING 4" UNDERGROUND PVC CONDUIT AND WATER LINES. 5 PROVIDE NEW 1/2" CW, 1/2" HW, 1/2" FW-1, & 1/2" FW-2 WATER LINES IN EXTENDED CONDUIT. CONNECT NEW PIPING TO EXISTING BRANCH MAINS. 6 ROUTE NEW 3/4" FW-1 FROM FILTERS TO ICE MACHINES. PROVIDE CODE COMPLIANT BACKFLOW PREVENTER AS SCHEDULED ON SHEET P2.00 FOR EACH ICE MACHINE. 7 ROUTE NEW 3/4" FW-2 FROM FILTERS DOWN IN WALL. PROVIDE 1/2" BRANCH TO EACH FROZEN CARBONATED BEVERAGE MACHINE WITH CODE COMPLIANT BACKFLOW PREVENTER SCHEDULED ON SHEET P2.00. 8 CONNECT TO EXISTING 1/2" COLD WATER PIPING. ROUTE LINE TO BEAN TO CUP MACHINE. PROVIDE SHUT OFF VALVE WITH 3/8" COMPRESSION FITTING FOR UP TO 2 MACHINES. 9 CONNECT TO EXISTING 1/2" FILTERED WATER. ROUTE LINE TO ICE MACHINE. PROVIDE CODE COMPLIANT BACKFLOW PREVENTER AS SCHEDULED ON SHEET P2.00. GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 NOTE: FOR PIPE SIZES 1 1/4" & SMALLER, USE INSULATION SIZED FOR A 1/4" LARGER PIPE TO ALLOW ROOM FOR INSULATION OVER HEAT TRACE CABLE. NOTE: ALL UNDERGROUND AIR, HOT & COLD WATER, HOT WATER RETURN & SUPPLY, REFRIGERANT, STEAM & CONENSATE PIPING TO BE INSULATED, ALSO SEE SPECIFICATIONS. INSULATION SCHEDULE (° F) 40° -180° 40° -180° FLUID TEMP. RANGE 100° -140° 35° -140°REFRIGERANT DOMESTIC HOT & COLD WATER ABOVE FLOOR DOMESTIC HOT & COLD WATER BELOW SLAB HEAT TRACED DOMESTIC HOT WATER ABOVE FLOOR SYSTEM TYPE 1/2" ARMAFLEX OR IMCOA 1/2" -1" 2" 1 1/4" -1 1/2" PIPE SIZES 1" 1 1/2" 2" FIBERGLASS INS. THICKNESS 1/2" ARMAFLEX OR IMCOA INSULATION TYPE DOMESTIC HOT WATER ABOVE FLOOR WITH HEAT TRACE DOMESTIC COLD WATER ABOVE FLOOR ALL 1" ROOF DRAIN & OVERFLOW DRAIN ABOVE FLOOR ALL 1" FIBERGLASS w/ VAPOR BARRIER 2 1/2"2 1/2" 3" OR LARGER SAME SIZE AS PIPE 1/2" -1" 2" OR LARGER 1 1/4" -2" 1" 1 1/2" 2" DOMESTIC HOT WATER ABOVE FLOOR WITHOUT HEAT TRACE DISHWASHER - ON HOT & COLD WATER LINES (WATTS # LF288A), ASSE 1001. WATTS # LF26A 0-25 PSI VALVE 3/4" LIQUID FILLED GAUGE 0-100 PS1. 3 COMPARTMENT SINK - FAUCETS W/ VACUUM BREAKERS WITH NO HOSE CONNECTION. FILTERED WATER SYSTEM (R.O.), SODA / CARBONATOR SYSTEM - WATTS # LFSD-3, ASSE 1022. COFFEE MACHINES CAPPACCINO MACHINES - WATTS # 9BD, ASSE 1052. PIPE DRAIN TO NEAREST FLOOR SINK, ASSE 1052. ICE MACHINES - WATTS # LF7U2-2 DUAL CHECK, ASSE 1024. R.O. FILTER SYSTEM - WATTS # LF007M1QT-S, ASSE 1015. PLUMBER PROVIDED & INSTALLED BACKFLOW PROTECTION & PRESSURE REDUCING CONVENIENCE STORE EQUIPMENT SCHEDULE EQUIPMENT SUPPLIED & SET BY SUPPLIER INDICATED ON FACILITIES EQUIPMENT DRAWINGS (EQ). ALL PLUMBING ROUGH-IN & FINAL PLUMBING CONNECTIONS BY PLUMBING CONTRACTOR. REFER TO EQ. DRAWINGS FOR EXACT ROUGH-IN, CONNECTION REQUIREMENTS LOCATIONS & DIMENSIONS. ALL HOT & COLD WATER CONNECTIONS TO EQUIPMENT SHALL BE MADE THRU VALVES OR STOPS EQUAL TO THOSE SPECIFIED FOR PLUMBING FIXTURES AND BRAIDED STAINLESS STEEL CONNECTORS. 2. WASTE & VENT, 3. CONDENSATE DRAINS: RAIN WATER BELOW GRADE: 1. DOMESTIC WATER:TYPE 'K' SOFT COPPER BELOW FLOOR OR GRADE w/ WROUGHT COPPER FITTINGS (BRAZED). TYPE 'L' HARD DRAWN COPPER TUBING w/ WROUGHT COPPER (95/5 SOLDER). FITTINGS ABOVE FLOOR OR GRADE. 3/4" -2 1/2" TYPE "K" SOFT COPPER 3" + DUCTILE IRON OR PVC CONFORMING TO AWWA STANDARDS SERVICE WEIGHT NO-HUB CAST IRON w/ MG' OR 'IDEAL' FITTINGS. SCHEDULE 40 GALV. STEEL FOR EXPOSED VENT LINES. ALL DRAINS & TRAPS TO BE CAST BRASS, CAST IRON OR GALV, STEEL. PLASTIC PIPING CONFORMING TO IAPMO AND ASTM SPECIFICATIONS IS ACCEPTABLE WHERE PERMITTED BY LOCAL CODES. NO PLASTIC PIPE IS PERMITTED IN RETURN PLENUM ATTIC. TYPE 'L' HARD DRAWN COPPER w/ WROUGHT COPPER SOLDER JOINT FITTINGS. WALK-IN COOLERS/FREEZERS: MINIMUM OF TYPE M COPPER PIPE WITH 95/5 SOLDER FITTING AND MEET NSF STANDARDS. NO COMBUSTIBLE PIPING OR MATERIAL SHALL BE RUN IN RETURN AIR PLENUM SPACE ABOVE CEILING. ALL UNDERGROUND WATER PIPING SHALL BE WRAPPED &/OR INSULATED PER SPECIFICATIONS. PIPE SPECIFICATIONS 1. DOMESTIC WATER: PEX PIPING MAY BE INSTALLED IN ALL CONCEALED SPACES, ABOVE CEILING, AND IN BETWEEN WALLS IF APPROVED BY THE LOCAL PLUMBING CODE. THE P.C. SHALL USE THE FOLLOWING: PEX PIPE:UPONOR -PAX a (ENGLE-METHOD CROSSLINKED POLYETHYLENE). ASTM 876/877. FITTINGS:UPONOR -PROPEX ENGINEERED POLYMER (EP) FITTINGS. ASTM 1960 AND ANSI/NSF 14 & ANSI/NSF 61. CONNECTORS:UPONOR -PROPEX RINGS (ENGLE-METHOD CROSSLONKED POLYETHYLENE). ANSI/NSF 14 & ANSI/NSF 61. SUPPORTS:UPONOR -PAX a PIPE SUPPORT (CHANNEL). GALVANIZED STEEL CHANNEL. FOR ASTME 84 INSTALLATIONS. ALL PIPE MUST BE COVERED WITH A PEX a PIPE SUPPORT OR A MINIMUM 1/2" THICK RATED INSULATION. REFER TO UPONOR INSTALLATION INSTRUCTIONS. "ALL EXPOSED PIPING SHALL BE TYPE "K" COPPER WITH WROUGHT FITTINGS." (NO SUBSTITUTIONS) : WRONG MATERIALS WILL BE REMOVED AND REPLACED AT THE PLUMBING CONTRACTORS EXPENSE. PEX PIPE ALTERNATE SPECIFICATIONS SYMBOL WDESCRIPTIONVCWHW PLUMBING FIXTURE SCHEDULE EQUIPMENT AND INSTALLATION BY PLUMBING CONTRACTOR UNLESS NOTED OTHERWISE P7 IW1/2" 1/2" 1 1/2" BAR SINK - THE SINKS TO BE FURNISHED AND INSTALLED BY THE MILL WORK CONTRACTOR. THE P.C. SHALL TRIM THESE SINKS OUT AND CONNECT THEM TO THE WATER AND SEWER SYSTEMS. PROVIDE AND INSTALL KOHLER K 15888/K 15850-4M-CP "CORALAIS" TWO HANDLE BAR FAUCET, KOHLER K 8807-3 1/2" SINK STRAINER, LEONARD MODEL 20300 THERMOSTATIC MIXING VALVE (SET THE OUTLET HOT WATER TEMPERATURE AT 105 TO 110 DEGREES), BRASSCRAFT KTCR19X C STOPS, ESCUTCHEONS, STAINLESSSTEEL BRAIDED SUPPLIES, AND 1 1/2" INDORECT WASTE TO FLOOR SINK. POSITION FAUCET AS SHOWN ON THE DRAWINGS. P9 3/4"___ WATER FILTER -OWNER FURNISHED, P.C. INSTALLED. P.C. TO FURNISH WATER LINES TO UNIT WITH SHUT OFF VALVE AND RUN FILTERED WATER (FW1) TO FIXURES OR KITCHEN EQUIPMENT SHOWN ON THE DRAWINGS. P12 P11 2" 2" ___ ___ BACKFLOW PREVENTER -WATTS LF009MSQT-S REDUCED PRESSURE BACKFLOW PREVENTER, IN-LINE CHECK VALVES, TEST COCKS, 2 SHUT OFF VALVES AND BRONZE STRAINER. PIPING DRAIN TO FLOOR SINK IN THIS ROOM. INSTALL 48”A.F.F. PRESSURE REDUCING VALVE -WATTS LFU5B, WITH BYPASS FOR THERMAL EXPANSION. SET REGULATOR FOR MINIMUM OF 55.5 PSI AT THE OUTLET, PROVIDE 0-200 PSI 2-1/2”FACE-PRESSURE GAUGE, AND BALL VALVES ON BOTH INLET & OUTLET ENDS OF RPZ. INSTALL AT 48”A.F.F. SEE DETAIL 15/P2.01. FS1 _ _1 1/2"2" FLOOR SINK -J.R. SMITH MODEL #3140Y02-PDBS, 12-1/2”X12-1/2”X6”, 2”OUTLET WITH POLISHED ALUMINUM DOME STRAINER. PROVIDE DEEP SEAL P-TRAPS WITH TRAP PRIMERS. IF APPROVED BY AUTHORITY HAVING JURISDICTION, P.C. MAY USE PROSET TRAP GUARDS IN LIEU OF TRAP PRIMERS. SEE DETAIL 3/P2.01. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 4 : 0 0 P M PLUMBING SCHEDULES 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL P2.00 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 _ ITEM DESCRIPTION MODEL/MFG. FW CW HW V W IW NOTES: 4 ICE/BEVERAGE DISPENSER FLAVOR SELECT/ FS60 3/8" - - - 3/4" TO FLOOR SINK 11 CAPPUCCINO MACHINE Bunn iMix-5S 1/4" - - - - TO FLOOR SINK 18 QUIETQUBE ICE MAKER HOSHIZAKI 3/8" - - - 3/4" TO FLOOR SINK 20A OVEN/RACK NU-VU-OP-4/8 M 1/4" - - - - -<varies> 21 ICE MAKER ( OVER BEV. DISP.) N13 22R-32 SCOTSMAN PRODIGY PLUS 3/8" - - - - TO FLOOR SINK 33 ICE CREAM MERCHANDISER ZERO ZONE - - - - - TO FLOOR SINK 51 STAINLESS STEEL SINK (HAND OR BAR) FURNISHED BY MILLWORK - 1/2" 1/2" 1-1/2" 2" TO FLOOR SINK 72.1 FROZEN CARBONATED BEV. ICEE-VIPER 4 FLAV.3/8" - - - 1/2" TO FLOOR SINK 96 F'REAL 11-CSGF-X1-FR RL 1/4" - - - 3/4" TO FLOOR SINK 115 BEAN TO CUP COFFEE MACHINE ART C TOUCH 3G/SCHAERER DNS ICE/BEVERAGE DISPENSER FLAVOR SELECT/ FS60 3/8" - - - 3/4" TO FLOOR SINK GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 UNION COOLING COIL PIPING SUPPORTS AT 5' O.C. AND AT CHANGES IN DIRECTION. SLOPE MIN. 1/4"/FT. WALK-IN COOLER OR FREEZER RUN TO BACK WALL & ROUTE ALONG WALLS TO RECEPTOR VENT WHEN REQUIRED ESCUTCHEON AIR GAP FLOOR SINK 2X PIPE DIA. NOTE: PIPE MATERIAL TO BE MINIMUM OF TYPE M COPPER PIPE. INDIRECT WASTE SCHEDULE INDIRECT WASTE LINE TO RECEPTOR TYPICAL METHODS FOR RUNNING CONNECTION AT CASE LOCAL AUTHORITY. BELOW RIM IF APPROVED BY NOTE: I.W. LINE MAY TERMINATE ENDS OPEN VERTICAL TEE WITH BOTH DISCHARGE POINT OPEN TEE TO BE BELOW CASE FLOOR SINKDRAIN LINE SUPPORTED AS SHOWN VENT AS REQUIRED 2X PIPE SIZE OUTLET. LGR. THAN PIPE SIZE MIN. ONE 1/2" I.D. LESS THAN BUT NOT OUTLET SAME AS YES NO NO YES YES NO OVER 15' 5'-15' 0-5' SIZE PIPE REQ'D VENT REQ'D TRAP LENGTH PIPE 2X PIPE SIZE FLOOR SINK VENT AS REQUIRED TRAP TRAP CONNECTION AT CASE (MIN) 2X PIPE DIA.THE LOCAL HEALTH DEPT. REQUIREMENTS DIRECTION OF THE BUILDING CODE AND NOTE: INSTALL FLOOR SINK AS PER THE FLOOR SINK OUTLET TO P-TRAP ALUMINUM DOME STRAINER CONCRETEALL FLOOR SINKS SHALL HAVE A TRAP PRIMER OR A TRAP SEAL. FINISHED FLOOR MATERIALSFINISHED FLOOR MATERIALS INSTALL DEEP SEAL P-TRAPS ON ALL FLOOR SINKS. FLOOR CLEANOUT LONG SWEEP FITTINGS 2" PIPE SINK 2" OR 3" PIPE 2" WALL CLEANOUT FOOT VENT 45° FITTING SLOPE SLOPE 2" PIPE 2" PIPE 2" PIPE 2" VENT THRU ROOF WALL NOTE: RAISE RETURN VENT AS HIGH AS POSSIBLE UNDER THE DRAIN BOARD. USE 2(45°) FITTINGS AND ONE LONG RADIUS ELBOW TO MAKE LOOP. INSTALL LONG SWEEP FITTINGS BELOW FLOOR AND RUN HORIZONTALLY TO NEAREST PARTITION. USE 45° FITTINGS FOR EASY STOPPAGE CLEANING. F S 1 1/2"FW1 TOP VIEW KITCHEN SERVICE R E A R V I E WWA L L I C E S O D A M A C H I N E O U T L E T DELI PREP DRINK YOGURT SLUSH A S P O S S I B L ECOUNTER. H O L D 1 " H O L E I N C L O S E T O U N I T D R A I N L I N E A S L I N E , M I N I M U M D R A I N3/4 " FLOOR CLEANOUT (FCO) CLEANOUT TO GRADE (COTG) WALL CLEANOUT (WCO) FLOOR LINE WALL WASTE LINE FLOOR LINE BALANCE OF PIPING SAME AS COTG BRASS C.O. PLUG W/ COUNTER-SUNK HEAD FINISHED GRADE 16" SQ. CONCRETE PAD. TROWEL SMOOTH AND BEVEL EDGES. CI WASTE LINE. LENGTH TO SUIT 1/8 CI BEND CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH W/ TOP OF FLOOR CHROME WALL COVER AND SCREW MAY EXTEND AS WASTE OR VENT CLEANOUT TEE W/ PLUG BALANCE OF PIPING SAME AS COTG 6" 1/8 CI BEND 1/8 CI BEND INSULATION (TYP.) HOT WATER LINE COLD WATER LINE UNISTRUT-LENGTH VARIES DEPENDING ON LINE SIZES AND NUMBER OF LINES BEING SUPPORTED. (USE P-4000 UNISTRUT) ATTACH 1/2" HANGER RODS TO MEMBER (TYP.) CONDUIT FOR ELECTRICAL WIRING OR OTHER PIPING NOTE: USE SIMILAR HANGERS FOR STEAM, CONDENSATE, AND AIR LINES. PROVIDE SEISMIC BRACING WHERE NECESSARY. 1 2 3 4 FEMALE x FEMALE LONG SWEEP BEND (TYP EACH END)COUPLER NOTES: EXTEND MIN. 7" THRU SLAB 100' MAX. SLAB A. B. PULL CORD PULL CORD CHASE SUPPLIED AND INSTALLED BY P.C. USE OF TEES, SHORT SWEEP 45° AND 90° ELLS IS NOT ALLOWED. CHASE SHALL BE LAID IN STRAIGHT RUNS BETWEEN RISER POINTS WITH THE USE OF ONLY TWO LONG SWEEP 90° ELLS (36" MINIMUM RADIUS) INTERIOR OF CHASE SHOULD BE SMOOTH WITH NO SHARP OR ROUGH JOINT EDGES TO RESTRICT OR CATCH BEVERAGE TUBING. 4"⌀MIN. PVC PIPE WITH PULL CORD ENTIRE RUN OF PIPE TO PULL BEVERAGE LINES. 2"⌀MIN. PVC PIPE FOR CO² LINE W/PULL CORD ALONG ENTIRE LENGTH OF PIPE. PROVIDE AND INSTALL TEMPORARY CAP OVER EACH RISER (USE NO CEMENT) 4"⌀X6" THICK FOAM CAP FOR BEVERAGE CHASE PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 4 : 0 1 P M PLUMBING DETAILS 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL P2.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 REFRIGERATION CONDENSATE DRAIN DETAIL SCALE:1/8" = 1'-0"2 TYPICAL INDIRECT WASTE DRAIN DETAIL SCALE:1/4" = 1'-0"3 FLOOR SINK (FS1 & FS2) DETAIL SCALE:1/4" = 1'-0"7 ISLAND SINK INSTALLATION DETAIL SCALE:1/4" = 1'-0"8 ICE BIN DRAIN LINE DETAIL SCALE:1/8" = 1'-0"4 CLEANOUTS DETAIL SCALE:1/8" = 1'-0"5 TYPICAL PIPE HANGER SUPPORT DETAIL SCALE:1/8" = 1'-0"6 BEVERAGE & CO 2 SUPPLY CHASE DETAIL GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 EXISTING GREASE WASTE CAPPED AT FLOOR EXISTING 3" VTR. TIE INTO EXISTING GREASE MAIN, FIELD VERIFY LOCATION OF MAIN 51 FS-1 FS-1 51 51 P7 P7 P7 (E)FS-1 (E)FS-1 (E)FD-1 (E)FS-1 (E)FS-1 (E)FS-1 (E)FS-1 (E)FS-1 (E)FD-1 (E)FD-1 (E)FD-1 (E)FS-1 (E)FD-1 (E)FS-1 (E)FD-1 (E ) 2 "ø V (E) 2"ø V (E ) 2 " ø V (E ) 2 " ø V (E) 2"ø V(E ) 2 "ø V (E ) 4 "ø G W (E ) 4 "ø G W (E) 2"ø V (E) 4"ø G W (E) 3"ø G W (E ) 2 "ø V (E ) 3 "ø G W(E) 3"ø G W (E) 3"ø G W (E ) 2 "ø S A N (E) 4"ø SAN(E) 4"ø SAN (E) 4"ø GW (E ) 2 " ø V (E ) 2 " ø V (E ) 2 " ø V (E ) 2 " ø V (E ) 2 "ø V(E) 1 1/2"ø V (E) 1 1/2"ø V EXISTING GREASE WASTE CAPPED AT FLOOR TIE INTO EXISTING VENT MAIN, FIELD VERIFY LOCATION OF MAIN 3"ø SAN 2"ø V 2"ø V 2"ø V 3"ø GW 51 P7 1 1/2"ø GW 1 1/2"ø GW 1 1/2"ø GW TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS 51 51 51P7 P7 P7 51 P7 1/ 2 " ø H W 1/ 2 " ø C W 1/ 2 " ø H W 1/ 2 " ø C W 1/ 2 " ø C W 1/ 2 " ø H W 1/ 2 " ø F W 3/ 4 " ø F W 3/ 4 " ø F W 1/2"ø FW 1/2"ø HW 1/2"ø CW TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS TIE WATER PIPING INTO EXISTING MAINS, FIELD VERIFY LOCATION OF MAINS 115 115 69 115 73 73 21 18 95 1/ 2 " ø F W 1/ 2 " ø F W 1/ 2 " ø F W 1/ 2 " ø H W 1/ 2 " ø C W PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 4 : 0 3 P M PLUMBING ISOMETRICS 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL P2.02 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1 WASTE RISER SCALE:2 WATER ISOMETRIC GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 GENERAL NOTES 1. THE ARCHITECTURAL, STRUCTURAL, PLUMBING AND ELECTRICAL DRAWINGS AND OTHER RELATED DOCUMENTS SHALL BE CONSIDERED A PART OF THE MECHANICAL CONTRACT, AS FAR AS THEY APPLY TO THE MECHANICAL SYSTEMS, AS IF REFERRED TO IN FULL. 2. ALL FIELD CONDITIONS AND JOB SITE DIMENSIONS ARE TO BE VERIFIED PRIOR TO COMMENCEMENT OF WORK. 3. ALL CONSTRUCTION WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE BUILDING CODES. (IMC, UMC, IBC, UBC, STATE AND LOCAL CODES). 4. THE LOCATION OF ALL PENETRATIONS SHALL BE COORDINATED WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS. 5. MECHANICAL CONTRACTOR SHALL PROVIDE LEVELING PLATFORM AND CURBS FOR ALL NECESSARY ROOF EQUIPMENT. COORDINATE WITH ROOF EQUIPMENT SUPPLIER. 6. ALL FIELD CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED PRIOR TO SUBMITTING BIDS, NO ALLOWANCE WILL BE MADE FOR NOT COMPLYING WITH THIS REQUIREMENT. 7. CONTRACTOR SHALL NEATLY LABEL ROOF MOUNTED EQUIPMENT WITH 4" MINIMUM LETTERING WITH PLAN EQUIPMENT NAME PLATE TAG #. I.E.: CU-18A, CU-21A 8. ALL EQUIPMENT SHALL BE FURNISHED WITH (THREE) MAINTENANCE MANUALS, EQUIPMENT SCHEDULES, TAGS AND LETTER OF GUARANTEE IN A BINDER(THREE) WITH TABS, AS PER PROJECT BOOK SPECIFICATION, SECTION 01700. 9. MAINTAIN 4'-0" SERVICE CLEARANCE BETWEEN PARAPET AND ROOF MOUNTED EQUIPMENT. 10. ALL REFRIGERATION PIPE SIZES SHALL BE PER MANUFACTURER'S RECOMMENDATIONS OR SPECIFICATIONS. USE 404A REFRIGERANT. 11. NO REFRIGERATION PIPE PENETRATIONS PERMITED IN RETAIL AREA. COORDINATE IN FIELD PRIOR TO PERFORMING WORK. 12. ICE MACHINES REQUIRE INSULATION ON BOTH LIQUID AND SUCTION LINES. ALL OTHER REFRIGERATION EQUIPMENT SHALL HAVE ONLY SUCTION LINES INSULATED. 13. ALL SITE ASSEMBLED REFRIGERATION PIPING SHALL BE SUBJECTED TO TESTING PER IMC SECTION 1108.1 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 3 : 4 5 P M MECHANICAL LEGENDS & NOTES 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL M0.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 WET BULB WB WEIGHT WT WATT W VOLUME VOL VALVE V THERMOSTAT T STAT TEMPERATURE DIFFERENCE TD TEMPERATURE TEMP SUPPLY AIR SA SUCTION SUCT STATIC PRESSURE SP STANDARD STD SQUARE SQ SPECIFICATION SPEC REFRIGERANT (12, 22, ECT.) R12, R22 PRESSURE, STATIC SP PRESSURE DROP PD PRESSURE PRES PSI GAGE PSIG POUNDS PER SQUARE INCH PSI POUNDS PER SQUARE FOOT PSF POUNDS LBS PHASE (ELECTRICAL)PH PERCENT % OUTSIDE AIR OA NUMBER NO. NOT TO SCALE NTS NOT IN CONTRACT NIC NORMALLY CLOSED N.C. NORMALLY OPEN N.O. NOISE CRITERIA NC MINIMUM MIN MILES PER HOUR MPH MAXIMUM MAX LIQUID LIQ LINEAR FEET LF LEAVING WATER TEMPERATURE LWT LEAVING AIR TEMPERATURE LAT LATENT HEAT LH KILOWATT KW FREQUENCY (ELECTRICAL) HZ DIAMETER DIA Ø DEW-POINT TEMPERATURE DPT BRAKE HORSEPOWER BHP AVERAGE AVG APPROXIMATE APPROX APPARATUS DEW POINT ADP AMPERE (AMP, AMPS)AMP AMBIENT AMB ALTERNATING CURRENT AC ABOVE FINISHED FLOOR AFF MECHANICAL ABBREVIATIONS CONNECT TO EXISTING PIPE RISING UP PIPE DROPPING DOWN REFRIGERANT LIQUID REFRIGERANT SUCTION EQUIPMENT DESIGNATION DESIGNATION NUMBER DIA. DIAMETER CD CONDENSATE SYMBOL & ABBREVIATION DESCRIPTION LEGEND MECHANICAL SYMBOLS RS RL CD 18, 18A THIS PROJECT CONSISTS OF AN EXISTING CONVENIENCE STORE REFRESH OF STORE FIXTURES AND STORE EQIUPMENT. NO MODIFICATIONS TO THE EXISTING HVAC SYSTEMS, IE: RTUS, DUCTWORK, HOOD OR THERMOSTATS, WITH THE FOLLOWING EXCEPTION: AN EXISTING SALES AREA DIFFUSER MAY REQUIRE A MINOR ADJUSTMENT TO REDIRECT THE AIRFLOW AWAY FROM THE NEW BONFIRE GRILL CANOPY AND NEW HOT DOG GONDOLA TO PREVENT AIR FROM BLOWING DIRECTLY ONTO EITHER OF THEM. THE EXISTING DRINK STATION AREA IS BEING RECONFIGURED AND THE EXISTING SODA/ICE DISPENSER IS BEING REPLACED WITH (2) TWO NEW SODA/ICE DISPENSERS WITH ROOF MOUNTED REMOTE CONDENSERS. THE INSULATED REFRIGERANT PIPING WILL ROUTE ON THE ROOF AND PENETRATE THE SPACE IN TO THE ADJACENT WALL. NO REFRIGERATE PIPING SHALL BE INSTALLED AND ROUTED THROUGH THE SALES AREA. THE EXISTING BACK OF HOUSE ICE MACHINE IS BEING REPLACED WITH AN ICE MACHINE WITH A REMOTE CONDENSING UNIT. THE CONDENSERS WILL BE MOUNTED AND ATTACHED TO A ROOF CURB. THE INSULATED REFRIGERANT PIPING WILL ROUTE ON THE ROOF AND PENETRATE THE SPACE INTO THE ADJACENT WALL. MECHANICAL DESIGN INTENT GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 G 2 1 1A 2A5A 3A4A 6A F 2.1 2.5 1A 2A5A 3A4A 6A 2 3 CONDENSING UNIT #18A (CUBE ICE MAKER) 325 LBS 18A 8A8A CONDENSING UNIT #21A (CUBE ICE MAKER#2) 130 LBS 7A 7A E D 3 1 4 4 SCOPE OF WORK REFRIGERATION CONTRACTOR SHALL INSTALL ALL OWNER PROVIDED EQUIPMENT (CONDENSERS, EVAPORATORS, EXPANSION VALVES, SOLENOID VALVES, & CONTROL VALVES). FOLLOW MANUFACTURER'S INSTALLATION MANUALS & THESE REFRIGERATION PLANS & DETAILS. REFRIGERATION CONTRACTOR SHALL PROVIDE ALL PIPING EXCEPT FOR THE ICE MACHINES. PROVIDE 1/2" INSULATION ON ALL PIPING. CONTRACTOR SHALL CHARGE EACH SYSTEM WITH REFRIGERATE TO THE PROPER VOLUMES PER MANUFACTURER'S EQUIPMENT MANUALS. WALL LIQUID LINE UNISTRUT SUCTION LINE 1/2" INSULATION (R-3) BRASS COUPLER PIPE SUPPORT INSTALL GASKET OR TAPE TO ISOLATE PIPE. B-LINE "VIBRACLAMP" BUT SERIES PIPE CLAMP COUPLER NOTE: PROVIDE SEISMIC BRACING WHERE NECESSARY. ROOF NOTE: PAINT EXPOSED REFRIGERATION PIPE INSULATION WITH TWO COATS OF WHITE FINISH TO PROTECT FROM UV RAYS. SLEEVE PROVIDED & INSTALLED BY REFRIGERATION CONTRACTOR ROOF SEALANT AROUND ENTIRE PIPE OPENING. ALLOW WATER TO DRAIN AWAY FROM OPENING ON TO THE ROOF CONDENSER WEATHER PROOF DISCONNECT LIQUID & SUCTION LINES WITH INSULATION ELECTRICAL CONDUIT CURB (BY ROOFING CONTRACTOR) SEISMIC BRACING #10 SHEET METAL SCREW 12" ON CENTER SEE 7/S5.10 FOR CURB ANCHORING DETAIL CONDENSER MOUNTING ANGLE ROUTE DOWN TO EQUIPMENT REFRIGERATION EQUIPMENT SCHEDULE 18A 18 21A 21 ICE MAKER #1 HOSHIZAKI 60"X17"X30"325 HOSHIZAK KMS-2000MLH208V/1∅21.3 30x24x33 2063/4"1/2"3/4"1/2" EQUIPMENT CONDENSER MANUFACTURER MODEL #VOLTAGE H.P.FLA MOPD WEIGHT EVAPORATOR MANUFACTURER MODEL #VOLTAGE H.P.MCA MOPD L x W x H DIMENSIONS WEIGHT L S LINE SIZES (LBS) LINE SIZES SRK-20H 30 CUBE ICE MAKER #2 SCOTSMAN ERC311-32 32"X34"X34"130 SCOTSMAN N1322R-32 208V/1∅13.9 23x24x27 2251/2"3/8"1/2"3/8"20 L SL x W x H DIMENSIONS POWERED BY #18A POWERED BY #21 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 2 : 5 3 : 4 8 P M MECHANICAL FLOOR PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 JDF DJR TYPE B REMODEL M1.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 MECHANICAL PLAN KEY NOTES 1 EXISTING TYPE II HOOD TO REMAIN. NO MODIFICATIONS REQUIRED. 2 EXISTING DUCTWORK TO REMAIN. NO MODIFICATIONS REQUIRED. 3 EXISTING DUCTWORK TO REMAIN. CONTRACTOR SHALL ADJUST DIFFUSER DIRECTIONAL THROW IF BLOWING ON NEW BONFIRE GRILL CANOPY. COORDINATE WITH STAFF TO ENSURE NO AIR BLOWS DIRECTLY ONTO PREPARED FOOD OR BEVERAGES. 4 CONTRACTOR SHALL CONFIRM THAT THE EXISTING EXHAUST FAN IS CAPABLE OF 350 CFM AND REBALANCE THE EXHAUST OUTLETS TO A MINIMUM OF 50 CFM PER FIXTURE. REPORT ANY DEFICIENCIES TO THE ENGINEER PRIOR TO PERFORMING ANY WORK. 1A INSTALL REFRIGERATION PIPING FROM ROOF CONDENSER TO EVAPORATOR, PROVIDE SWEEPING ELBOWS IN SUCTION LINES. INSTALL 1/2" THICK INSULATION ON SUCTION LIN. SEE ALL INSULATION JOINTS WITH TAPE. PAINT INSULATION EXPOSED ON THE ROOF WITH (2) TWO COATS WHITE FINISH TO PROTECT INSULATION FROM UV RAYS. SEE REFRIGERATION DETAIL ON THIS SHEET. 2A SEAL ALL ROOF & REFRIGERANT CASE WALL & CEILING WITH EXPANDABLE INSULATION. PROVIDE FLASHING AROUND EXPOSED PIPES. 3A SUPPORT REFRIGERATION PIPES EVERY 6 FEET. ISOLATE PIPING WITH GASKET OR TAPE FROM PIPE COUPLER. 4A CONDENSER & EVAPORATOR, CONDUIT & POWER BY ELECTRICAL CONTRACTOR. CONTROL CONDUIT BY ELECTRICAL CONTRACTOR. INSTRUCT ELECTRICAL CONTRACTOR ON ROUTING OF CONTROL CONDUIT. CONTROL WIRE BY ELECTRICAL CONTRACTOR. ALL FINAL CONDENSER, EVAPORATOR, SOLENOID & STAT. CONTROL WIRING BY ELECTRICAL CONTRACTOR. START UP BY REFRIGERATION CONTRACTOR. REFRIGERATION CONTRACTOR TO SEAL CONDUIT PENETRATIONS WITH EXPANDABLE FOAM INSULATION. 5A INSULATE BOTH REFRIGERATION PIPES. INSTALL 1/2" THICK INSULATION ON BOTH SUCTION AND LIQUID LINES. SEAL ALL INSULATION JOINTS WITH TAPE. PAINT INSULATION EXPOSED ON THE ROOF WITH TWO (2) COATS WIHTE FINISH TO PROTECT INSULATION FROM UV RAYS. SEE REFRIGATION DETAIL ON THIS PAGE 6A ROUTE REFRIGERATION PIPES DOWN WALL BEHIND ICE MAKERS. PENETRATE WALL AND CONNECT TO ICE MAKER. HIDE PIPING FROM VIEW. 7A INSTALL CONDENSER ON ROOF CURB AND ATTACH WITH #10 SHEET METAL SCREWS 12" ON CENTER. 8A CONTRACTOR SHALL RECLAIM REFRIGERANT FROM EXISTING ICE MACHINES PRIOR TO DEMOLITION IN ACCORDANCE WITH LOCAL AND NATIONAL CODE REQUIREMENTS.CONTRACTOR SHALL REMOVE CONDENSING UNITS FROM ROOF. SEE ARCHITECTURAL DEMOLITION SHEET FOR ADDITIONAL INFORMATION AND FOR COORDINATION PRIOR TO PERFORMING WORK. REFRIGERATION NOTES SCALE:1/8" = 1'-0"3 REFRIGERATION PIPING ON ROOF DETAIL SCALE:1/8" = 1'-0"2 REFRIGERANT PIPING DETAIL GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 ELECTRICAL GENERAL NOTES GENERAL NOTES: 1. APPLICABLE CODES: SEE TITLE SHEET. 2. THE ELECTRICAL SYSTEMS DEFINED BY THESE PLANS AND THE SPECIFICATIONS ARE TO BE CONSTRUCTED AS COMPLETE AND OPERABLE SYSTEMS AND SHALL BE BID WITH THIS INTENT. THE CONTRACTOR SHALL VISIT THE SITE, READ ALL THE RELEVANT DOCUMENTS, AND BECOME FAMILIAR WITH THE TYPE OF CONSTRUCTION AND WORK TO BE ACCOMPLISHED. SHOULD ANY ERROR, OMISSION, OR CONFLICT EXIST IN EITHER THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING BEFORE SUBMITTING THEIR BID PRICE SO A CHANGE CAN BE ISSUED IN A PRE-BID ADDENDUM. OTHERWISE, THE CONTRACTOR AND/OR EQUIPMENT SUPPLIERS SHALL SUPPLY THE PROPER MATERIALS AND LABOR TO INSTALL COMPLETE AND OPERABLE SYSTEMS INCLUSIVE OF THE ORIGINAL BID. WHEN EACH ELECTRICAL SYSTEM IS COMPLETE, THE CONTRACTOR SHALL TEST AND CONFIRM ITS PROPER OPERATION. ANY INCOMPLETE SYSTEM SHALL BE MADE COMPLETE AND OPERABLE PRIOR TO PROJECT CLOSEOUT. 3. THE ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF THE ELECTRICAL DOCUMENTS SO FAR AS ANY ELECTRICAL ITEMS THEY MAY CONTAIN. THE ELECTRICAL CONTRACTOR SHALL REFER TO AND COORDINATE WITH THEM. NO EXTRA COST SHALL BE ALLOWED FOR FAILURE TO COORDINATE THE CONTRACT DOCUMENTS WITH OTHER TRADES AND/OR IF EQUIPMENT DIMENSIONS ARE GREATER THAN SPECIFIED AND/OR DIMENSIONED ON THE PLANS. 4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE EQUIPMENT, MATERIALS, AND LABOR FOR THE CONNECTIONS OF ALL EQUIPMENT SHOWN ON THE PLANS - ARCHITECTURAL, MECHANICAL, ETC. 5. THIS PROJECT IS TO BE INSTALLED IN STRICT ACCORDANCE WITH THE MOST RECENT LOCAL, STATE, AND NATIONAL CODES. IF AT ANY TIME DURING OR AFTER CONSTRUCTION SOMETHING IS FOUND TO BE INSTALLED IN VIOLATION OF THESE CODES LISTED ABOVE, IT SHALL BE CORRECTED BY THE CONTRACTOR. 6. ALL EQUIPMENT PROVIDED BY THE EC SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING AGENCY, ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION, AND BE PROPERLY INSTALLED FOR THE CONDITIONS AND SPACE THAT EQUIPMENT IS BEING INSTALLED WITHIN. 7. THE EC SHALL INSTALL A SEPARATE EQUIPMENT GROUNDING CONDUCTOR IN EACH CONDUIT RUN. CONDUIT SHALL NOT BE USED AS AN EQUIPMENT GROUNDING CONDUCTOR. THE EC SHALL GROUND THE ELECTRICAL SYSTEM IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. 8. CONDUIT LAYOUTS SHOWN ON THE PLANS ARE DIAGRAMMATIC, NOT INDICATING THE ROUTING REQUIRED. THE EC SHALL ROUTE THE CONDUITS AS REQUIRED BY THE CONDITIONS OF THE INSTALLATION AND SHALL COORDINATE WITH DUCTWORK, PIPING, EQUIPMENT, BUILDING STRUCTURE, AND OTHER POTENTIAL OBSTRUCTIONS. 9. THE CONTRACTOR SHALL ALLOW THE MOVEMENT, BEFORE ROUGH-IN, OF ANY ELECTRICAL PANEL, DEVICE, LUMINAIRE, ETC. A DISTANCE OF 10 FEET WITHOUT REQUIRING ADDITIONAL COST TO THE PROJECT. 10. THE EC SHALL SECURE ALL CONDUIT TO THE STRUCTURE AS IT IS SET IN PLACE USING INDUSTRY STANDARD METHODS AND PRACTICES. TO ASSURE ALL DEVICES ARE RIGIDLY SET, THE ELECTRICAL CONTRACTOR SHALL SECURE ALL DEVICE BOXES WITH BRACKETS, HANGERS, ETC. DESIGNED FOR THE APPLICATION. 11. MINIMUM SIZE CONDUIT SHALL BE 3/4" UNO. CONDUIT INSTALLED WITHIN THE BUILDING IN DRY LOCATIONS WITHIN WALL, CEILINGS, OR EXPOSED NOT SUBJECT TO PHYSICAL DAMAGE SHALL BE EMT WITH STEEL SET SCREW FITTINGS. IN EXTERIOR LOCATIONS (EXCEPT FOR THE SERVICE ENTRANCE) THE CONDUIT SHALL BE EMT WITH COMPRESSION GLAND TYPE FITTINGS. UNDERGROUND CONDUIT SHALL BE PVC (SCH. 40) WITH GRC ELBOWS AND RISERS WRAPPED IN CORROSION RESISTANT MATERIALS WHERE IN DIRECT CONTACT WITH THE SOIL. 12. FLEXIBLE CONDUIT SHALL BE LIMITED TO CONNECTIONS TO LIGHT FIXTURES AND FINAL CONNECTIONS TO MOTORS OR OTHER EQUIPMENT SUBJECT TO VIBRATION. LENGTHS OF FLEXIBLE OR SEAL-TITE CONDUIT SHALL NOT BE GREATER THAN 72 INCHES. 13. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL EMPTY CONDUITS WITH 200LB RATED NYLON PULL CORD. 14. BEFORE ANY ELECTRICAL CONDUIT, BOXES, ETC. ARE COVERED (FLOOR, CEILINGS, WALLS, ETC.), THEY SHALL BE APPROVED BY THE INSPECTING OFFICER (INSPECTOR). 15. WHERE WIRE SIZE IS NOT SHOWN ON THE DRAWINGS FOR 20A, 120VAC BRANCH CIRCUITS, THE CIRCUIT SHALL CONSIST OF 2#12 (CU,THWN) + 1#12 (CU,THWN) GND IN 3/4" EMT CONDUIT. THIS WIRE SIZE SHALL BE INCREASED TO #10 (CU,THWN) FOR BRANCH CIRCUITS WITH OVERALL LENGTHS EXCEEDING 125' TO ACCOMMODATE FOR VOLTAGE DROP. REFER TO EQUIPMENT SCHEDULES, FEEDER SCHEDULES, AND NOTES ON DRAWINGS FOR ALL OTHER BRANCH CIRCUIT AND FEEDER WIRE/CONDUIT SIZING. 16. CONDUCTORS SHALL BE COPPER, 600VAC RATED, TYPE THHN/THWN-2 UNO. CONDUCTORS UP TO #10AWG SHALL BE SOLID AND CONDUCTORS #8AWG OR LARGER SHALL BE STRANDED. 17. METAL CLAD CABLING MAY BE USED BETWEEN DEVICES SUCH AS LIGHTING, RECEPTACLES, SWITCHES, ETC. UNLESS OTHERWISE REQUIRED BY THE NEC. HOME RUNS SHALL BE INSTALLED IN CONDUIT. MC CABLE SHALL NOT BE INSTALLED EXPOSED. 18. EC SHALL CLEAN THE ENTIRE ELECTRICAL SYSTEM AFTER COMPLETION OF THE INSTALLATION. REMOVE ALL FINGER PRINTS, FOREIGN MATTER, PAINT, DIRT, GREASE, AND UN-NEEDED LABELS OR STICKERS FROM FIXTURES AND EQUIPMENT. REMOVE ALL RUBBISH AND DEBRIS ACCUMULATED DURING INSTALLATION FROM THE PREMISES. 19. IT IS THE INTENT OF THE CONSTRUCTION DOCUMENTS FOR ALL DEVICES TO BE FLUSH MOUNTED AND CONDUIT/CABLING INSTALLED CONCEALED WITHIN WALLS/CEILINGS. IN AREAS WHERE CONDUIT MUST BE INSTALLED EXPOSED IT SHALL BE COORDINATED WITH THE ARCHITECT AND/OR ENGINEER. ALL EFFORTS SHALL BE MADE TO CONCEAL WIRING METHODS. 20. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE SEALED WITH FIRE STOPPING, IE. 3M BRAND CAULK, PUTTY, STRIP AND SHEET FORMS, DOW CORNING 3-6548 SILICONE RTV FOAM. 21. COORDINATE LOCATION OF WALL MOUNTED DEVICES WITH CABINETRY AND OTHER WALL OBSTRUCTIONS. COORDINATE CEILING MOUNTED DEVICES WITH CEILING OBSTRUCTIONS. ANY DEVICES THAT NEED TO BE RELOCATED MUST BE BROUGHT TO THE ATTENTION OF THE ELECTRICAL ENGINEER PRIOR TO ROUGH-IN FOR NEW LOCATION. 22. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE PLACEMENT OF ALL DEVICES INSTALLED WITHIN THE CEILING SUCH AS LIGHTING, SPEAKERS, FIRE SPRINKLERS, SMOKE/HEAT DETECTORS, ETC. 25. NOT USED 26. PRIOR TO TRENCHING IN ANY AREA, THE CONTRACTOR SHALL COORDINATE WITH COMMUNICATIONS/DATA, CABLE TV, GAS, AND WATER UTILITY PROVIDERS (BLUE STAKES), AND HAVE ALL UTILITIES IN THE AREA IDENTIFIED. IN ADDITION, THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A SUBCONTRACTOR SPECIALIZING IN THE LOCATION OF UNDERGROUND STRUCTURES TO IDENTIFY ANY OBSTACLES IN THE PATH OF TRENCHING PRIOR TO COMMENCING WORK. DAMAGE TO ANY UNDERGROUND STRUCTURES SHALL BE REPAIRED BY THE CONTRACTOR. LIGHTING NOTES: 27. ALL BATTERY POWERED OR CONTINUOUS BURN LUMINAIRES SHOWN ON THE PLANS, SUCH AS EXIT LIGHTS, NIGHT LIGHTS, OR EMERGENCY LIGHTS, SHALL BE CONNECTED TO THE UN-SWITCHED LEG OF THE LIGHTING CIRCUIT FEEDING THAT AREA. 28. ALL LUMINAIRES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE AND NOT THE CEILING GRID OR OTHER NONSTRUCTURAL MEMBERS. 29. TO MAINTAIN CONSISTENT LIGHT QUALITY, FOR ANY ONE LAMP TYPE SUPPLIED, LAMPS SHALL BE OF THE SAME MANUFACTURER, SURFACE TEMPERATURE, COLOR RENDERING INDEX, LAMP EFFICACY, LUMEN OUTPUT, AND STARTING CHARACTERISTICS FOR ALL INSTALLED. 30. LIGHT FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE UL LISTED FOR INSTALLATION IN THE PROPER ENVIRONMENT. CARE SHOULD BE TAKEN TO ENSURE THAT DIFFUSERS AND LENSES ARE APPROPRIATE FOR THEIR INSTALLED USE AND PREMATURE DISCOLORATION WILL NOT RESULT DUE TO EXPOSURE TO UV LIGHT, CHEMICALS, OR OTHER CONDITIONS. POWER NOTES: 31. ELECTRICAL CONTRACTOR SHALL CONFIRM MINIMUM CODE (NEC) WORKING CLEARANCE BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS AND SHALL MOVE THE PANELS IF REJECTED BY AN INSPECTOR. IF CLEARANCE IS NOT POSSIBLE, THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY IN WRITING. 32. WIRING DEVICES SHALL BE WHITE IN COLOR WITH NYLON COVER PLATES. EXTERIOR OUTLETS SHALL HAVE CAST COVERS WITH FLIP TYPE LIDS UNO. 33. THE EC SHALL MAINTAIN ELECTRICAL CONTINUITY TO REMAINING EQUIPMENT WHEN ANY EXISTING ELECTRICAL EQUIPMENT IS REMOVED. 34. EC SHALL COORDINATE WITH EQUIPMENT SUPPLIERS ON THE EXACT LOCATIONS OF ALL EQUIPMENT AND ELECTRICAL CONNECTIONS PRIOR TO ROUGH-IN. THE EC SHALL MAKE THE FINAL CONNECTION TO ALL EQUIPMENT UNLESS OTHERWISE DIRECTED BY THE EQUIPMENT SUPPLIER. OBTAIN FROM SUPPLIERS ALL WIRING DIAGRAMS FOR EQUIPMENT PRIOR TO ANY ROUGH-IN. TO ASSURE THAT PROPER CHARACTERISTICS ARE PROVIDED, ANY INCORRECT WIRING OR DEVICES INSTALLED BY THE EC WITHOUT THE WIRING DIAGRAM SHALL BE CORRECTED AT THE EC'S EXPENSE. PROVIDE COPIES OF WIRING DIAGRAMS WITHIN EACH PIECE OF EQUIPMENT AND ADDITIONAL COPIES WITH THE OPERATION AND MAINTENANCE MANUALS. 35. EC SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO PROVIDE CONDUIT AND DEVICE MOUNTING BOXES FOR THERMOSTATS AND OTHER MECHANICAL CONTROLS. REFER TO MECHANICAL DRAWINGS FOR THE LOCATION OF THERMOSTATS. 36. PROVIDE A 20AMP, 120VAC RECEPTACLE INSTALLED AT AN ACCESSIBLE LOCATION FOR THE SERVICING OF HEATING, AIR CONDITIONING, AND REFRIGERATION EQUIPMENT PER NEC 210.63. RECEPTACLE SHALL BE OF THE GROUND FAULT CIRCUIT INTERRUPTING TYPE, INSTALLED WITHIN A CAST METAL BOX, AND WITHIN 25' OF ALL REQUIRED EQUIPMENT. DATA/TELECOM NOTES: 37. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ROUGH-IN ONLY FOR THE TELECOM/CATV SYSTEMS. THIS SHALL CONSIST OF A FOUR SQUARE DEVICE MOUNTING BOX WITH CONDUIT TO ABOVE ACCESSIBLE CEILING SPACE OR TO THE CEILING SPACE ABOVE IF OPEN. CABLING, JACKS, FACEPLATES, TESTING AND TERMINATIONS SHALL BE PROVIDED AND INSTALLED BY OTHERS. ROOF NOTES: 38. ELECTRICAL CONTRACTOR TO INSTALL A ROOF JACK (BOOT) FOR ALL CONDUIT PENETRATIONS THROUGH THE ROOF. ALL ROOF PENETRATION SEALS SHALL BE IN ACCORDANCE WITH THE ROOF WARRANTY AND BE COMPLETELY SEALED WITH ROOF ADHESIVE. UTILIZE PROPER CLAMPING METHODS TO SEAL BOOT AROUND CONDUIT. ELECTRICAL SYMBOL SCHEDULE SYMBOL DESCRIPTION MOUNTING NOTES CO AR MM F FIRE ALARM HORN 7' - 6" FIRE ALARM STROBE 7' - 6" FIRE ALARM HORN STROBE 7' - 6" FIRE ALARM GONG 7' - 6" FIRE ALARM DUAL ACTION MANUAL PULL STATION 4' - 0" FIRE ALARM ADDRESSABLE CONTROL RELAY FIRE ALARM MONITOR MODULE FIRE ALARM CONTROL PANEL 6' - 6" TO TOP FIRE ALARM ANNUNCIATOR PANEL 4' - 0" PHOTOELECTRIC SMOKE DETECTOR RATE OF RISE/HEAT DETECTOR CARBON MONOXIDE DETECTOR DUCT SMOKE DETECTOR 6 FIRE SMOKE DAMPER FIRE RISER TAMPER SWITCH FIRE RISER FLOW SWITCH ELECTROMAGNETIC DOOR HOLDER 2' - 0" F T SURFACE SURFACE SURFACE DUCT S S S S S S S LIGHT FIXTURE - SURFACE OR RECESSED SEE DRAWINGS 1 EMERGENCY LIGHT FIXTURE - SURFACE OR RECESSED SEE DRAWINGS 1, 2 EMERGENCY LIGHT FIXTURE - OPEN STRIP LIGHT FIXTURE - CEILING MOUNTED CEILING 1 LIGHT FIXTURE - PENDANT/CHANDELIER CEILING 1 LIGHT FIXTURE - DOWNLIGHT CEILING 1 LIGHT FIXTURE - WALL WASH DOWNLIGHT CEILING 1 LIGHT FIXTURE - WALL MOUNTED WALL 1 LIGHT FIXTURE - WALL BRACKET WALL 1 LIGHT TRACK WITH FIXTURES SURFACE 1 EXIT FIXTURE - WALL MOUNT WALL EXIT FIXTURE - CEILING MOUNT CEILING EXIT FIXTURE W/ EMERGENCY HEADS - WALL MOUNT WALL EXIT FIXTURE W/ EMERGENCY HEADS - CEILING MOUNT CEILING DUAL HEAD EMERGENCY LIGHT FIXTURE WALL 1, 2 AREA LIGHT FIXTURE - POLE MOUNTED POLE 1 PHOTO-ELECTRIC CELL WITH RELAY SURFACE 1 OCCUPANCY SENSOR - CEILING MOUNT CEILING 1 LIGHTING RELAY/POWER PACK SURFACE 1 TIME CLOCK - 7 DAY 5' - 0" WALL OCCUPANCY SENSOR SWITCH 4' - 0" SINGLE POLE SWITCH 4' - 0" DOUBLE POLE SWITCH 4' - 0" THREE WAY SWITCH 4' - 0" FOUR WAY SWITCH 4' - 0" DIMMER SWITCH 4' - 0" LOW VOLTAGE SWITCH 4' - 0" OS 2 3 4 D LV 1, 2, 3 1, 2, 3 1, 2, 3 1, 2, 3 LIGHT FIXTURE - OPEN STRIP 1 1, 2 SEE DRAWINGS SEE DRAWINGS EMERGENCY LIGHT FIXTURE - WALL MOUNTED WALL 1, 2 EMERGENCY LIGHT FIXTURE - WALL BRACKET WALL 1, 2 EMERGENCY LIGHT FIXTURE - DOWNLIGHT CEILING 1, 2 TC PP PC EM JUNCTION BOX SURFACE WALL JUNCTION BOX 1' - 6" UNO FLOOR JUNCTION BOX FLOOR DISCONNECT SWITCH - NON-FUSED 5' - 0" UNO 4 DISCONNECT SWITCH - FUSED 5' - 0" UNO 4 COMBINATION MAGNETIC STARTER/DISCONNECT 5' - 0" UNO MOTOR STARTER 5' - 0" UNO CONTACTOR 5' - 0" UNO MOTOR SURFACE METER - PLAN VIEW PUSH BUTTON SWITCH 4' - 0" EMERGENCY POWER SHUTOFF SWITCH 4' - 0" PANELBOARD - SURFACE MOUNTED 6' - 6" TO TOP PANELBOARD - RECESSED 6' - 6" TO TOP TRANSFORMER - PLAN VIEW TELEPHONE TERMINAL BOARD WALL WALL PAD/FLOOR DISCONNECT SWITCH - SHUNT TRIP F J J J 5' - 0" UNO 4 LPNR CIRCUIT BREAKER MCB PANEL - ONE-LINE MLO PANEL - ONE-LINE CURRENT TRANSFORMER CT ENCLOSURE - ONE-LINE TRANSFORMER - ONE-LINE PAD MOUNT XFMR - ONE-LINE METER - ONE-LINE FUSED SWITCH GROUND OH RISER CABLE/WIRE SIZE TAGXXX XXXA XXXAXP AUTOMATIC TRANSFER SWITCH GROUND SLEEVE - ONE-LINE FUSED DISCONNECT - ONE-LINE M S S XX X X KEYED NOTE TAG MECHANICAL/ELECTRICAL EQUIPMENT TAG OTHER EQUIPMENT TAG X ABBREVIATIONS NOTES WIRING / CONDUIT UNDERGROUND/FLOOR WIRING CONDUIT TURNED UP CONDUIT TURNED DOWN CIRCUIT HOME RUN TO PANEL: # OF ARROWHEADS INDICATE # OF CIRCUITS (SEPARATE NEUTRAL PER CIRCUIT). BOTH EX. INCLUDE AN EQUIP. GROUND. 1.SEE LIGHTING FIXTURE SCHEDULE FOR TYPE, MOUNTING, AND OTHER SPECIFICS. 2.CONNECT EMERGENCY AND/OR EXIT LIGHTS TO THE UNSWITCHED SIDE OF THE AREA LIGHTING BRANCH CIRCUIT. 3.ARROW DENOTES EXIT DIRECTION. 4.USE HEAVY DUTY FOR 480 VOLT. 5.MOUNT SWITCH AT DOOR JAM PER MANUFACTURER'S INSTRUCTIONS. 6.PROVIDE UL LISTED DEVICE TO BE USED WITH THE FIRE ALARM PANEL/SYSTEM OR PROVIDE A MONITOR MODULE TO CONNECT INTO FIRE ALARM SYSTEM. 7.PROVIDE RACEWAY WITH OUTLETS 12" ON CENTER UNO. MCB - MAIN CIRCUIT BREAKER MCC - MOTOR CONTROL CENTER MDP - MAIN DISTRIBUTION PANEL MLO - MAIN LUGS ONLY (N) - NEW NIC - NOT IN CONTRACT NEC - NATIONAL ELECTRICAL CODE NFPA - NATIONAL FIRE PROT. ASSN. NL - NIGHT LIGHT NR - NOT REQUIRED NTS - NOT TO SCALE PC - PLUMBING CONTRACTOR PNL - PANEL POC - POINT OF CONNECTION POS - POINT OF SALE (R) - RELOCATED REC - RECEPTACLES RMC - RIGID METAL CONDUIT SCA - SHORT CIRCUIT AMPERES SES - SERVICE ENTRANCE SWITCHGEAR SPD - SURGE PROTECTIVE DEVICE TTB - TELEPHONE TERMINAL BOARD TR - TAMPER RESISTANT TYP - TYPICAL UNO - UNLESS NOTED OTHERWISE VA - VOLT/AMPS VIF - VERIFY IN FIELD VR - VANDAL RESISTANT WP - WEATHERPROOF/NEMA 3R WU - WITH UNIT XFMR - TRANSFORMER AFCI - ARC FAULT CKT INTERRUPTER AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AIC - AMPS INTERRUPTING CAPACITY AL - ALUMINUM ATS - AUTOMATIC TRANSFER SWITCH BC - BARE COPPER BFC - BELOW FINISHED CEILING BFG - BELOW FINISHED GRADE CKT - CIRCUIT CND. OR C. - CONDUIT CLG - INSTALLED IN CEILING C.R. - CORD REEL CT - CURRENT TRANSDUCER CU - COPPER (E) - EXISTING TO REMAIN EC - ELECTRICAL CONTRACTOR EM - EMERGENCY (F) - FUTURE FACP - FIRE ALARM CONTROL PANEL FLA - FULL LOAD AMPS FVNR - FULL VOLTAGE NON REVERSING GC - GENERAL CONTRACTOR GFCI - GROUND FAULT CKT INTERRUPTER GND - GROUND IG - ISOLATED GROUND LCP - LIGHTING CONTROL PANEL LTG - LIGHTING LV - LOW VOLTAGE MC - MECHANICAL CONTRACTOR MCA - MINIMUM CIRCUIT AMPS THERMAL OVERLOAD SWITCH 4' - 0" UNO PILOT LIGHT SWITCH 4' - 0" DUPLEX OUTLET, 20A, 120VAC 1' - 6" UNO DUPLEX OUTLET, 20A, 120VAC - GFCI DUPLEX OUTLET - SPLIT WIRED DUPLEX OUTLET - ISOLATED GROUND DUPLEX OUTLET WITH USB PORTS DUPLEX OUTLET - OCCUPANCY SENSOR CONTROLLED DUPLEX OUTLET, 20A, 120VAC - CEILING CEILING DUPLEX OUTLET, 20A, 120VAC - FLOOR FLOOR FOURPLEX OUTLET, 20A, 120VAC FOURPLEX OUTLET, 20A, 120VAC - GFCI FOURPLEX OUTLET - ISOLATED GROUND APPLIANCE OUTLET - 208/240V SINGLE PHASE 18" OR 48" APPLIANCE OUTLET - 208/480V 3-PHASE 18" OR 48" TELEPHONE OUTLET DATA OUTLET DUAL TELEPHONE/DATA OUTLET CABLE TELEVISION OUTLET DUAL TELEPHONE/DATA OUTLET - FLOOR FLOOR TH P OS CEILING DATA OUTLET/ WIRELESS ACCESS POINT CEILING DATA OUTLET - FLOOR FLOOR 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO 1' - 6" UNO SPEAKER CEILING SECURITY CAMERA CEILING S APPLIANCE OUTLET - 208/240V SINGLE PHASE - GFCI 18" OR 48" APPLIANCE OUTLET - 208/480V 3-PHASE - GFCI 18" OR 48" 8.FOR ALL GFCI RECEPTACLES THAT ARE INACCESSIBLE, CONTRACTOR SHALL USE GFCI BREAKERS. 23. NOT USED 24. NOT USED PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 9 / 2 0 2 3 9 : 4 6 : 2 5 A M ELECTRICAL NOTES & SCHEDULES 2022020.40 FINAL DRAWINGS 01/20/2023 WCF KMD TYPE B REMODEL E0.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 01/20/23 All electrical work to comply with 2017 N E C S J J J S S J JJJJ 33 22 20D 2 2 2 2 2 1 11 1 1 1 1 A-63,65 B-64 18 3 CLGCLG CLG CLG 66 6 6 'M1' 71 8 8 B-62 1 8 'A' 94 18"18" 18" 10 12 AC AC A-68 14 PROVIDE ACCESS PANEL FOR ABANDONED CABLING 15 15 15 15 15 A-72 16 16 A-71 49395 111 21 4 18 15 15 1 74 A-70 8 8 15 16 48 14 1 1 1 1 1 (7) 3/4"C. (1) 1"C. EMS 9 (6) 3/4"C. 11 12 12 15 CLG 115 (5) 3/4"C. (1) 1" C. EMS 9 12 13 1 13 6 101 101 2 2 115 1 20A 5 'B' 'C''D' A-66 A-70 A-70 46 1 111 22 1B-68,70,72 1 1 17 CLG 8 10 115 11 69 1 1 7373 74 20 19B-71 3 B-66 B-69 19 A-39 B-66 B-35,37 2 2 2 2 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 9 / 2 0 2 3 9 : 4 6 : 2 6 A M ELECTRICAL POWER PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 WCF KMD TYPE B REMODEL E3.00 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 ELECTRICAL POWER PLAN KEYED NOTES GENERAL NOTESKEYED NOTES 1. COORDINATE WITH OWNER ALL DATA OUTLET REQUIREMENTS. LOCATE ON PLAN AND PROVIDE NECESSARY. 2. ALL SINGLE PHASE RECEPTACLES 50A AND LESS AND THREE PHASE RECEPTACLES 100A AND LESS THAT ARE 150V TO GROUND OR LESS IN THE KITCHEN, FOOD PREP AREAS, FOOD SERVICE AREAS AND BAR AREAS AND AREAS WHERE RECEPTACLES ARE INACCESSIBLE TO BE GFCI PROTECTED BY GFCI BREAKER. REFER TO EQUIPMENT CONNECTION SCHEDULE NOTES FOR GFCI BREAKER REQUIREMENTS. 3. PROVIDE AND MAINTAIN REQUIRED WORKSPACE, ADEQUATE ILLUMINATION, ACCESS TO WORK SPACE AND HEAD ROOM FOR AND ABOVE ELECTRICAL EQUIPMENT. NO PIPING, DUCTS OR EQUIPPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN A SPACE EXTENDING FROM THE FLOOR TO A HEIGHT OF 6' ABOVE THE EQUIPMENT. PROVIDE PROTECTION FROM PHYSICAL DAMAGE FOR SWITCHBOARDS, PANEL BOARDS, AND OTHER ELECTRICAL EQUIPMENT. NEC 110.27(B). 1 NEW EQUIPMENT TO REPLACE EXISTING EQUIPMENT. E.C. SHALL RUN NEW WIRE AND CONDUIT BACK TO EXISTING CIRCUIT 2 EXISTING TO REMAIN 3 PROVIDE DATA AND POWER OUTLET IN WALL FOR TV. COORDINATE EXACT LOCATION WITH OWNER. PROVIDE AND INSTALL ONE (1) 1" CONDUIT WITH FOUR (4) CAT-6 CABLES FROM JACK TO NETWORK RACK. LEAVE 18" OF SLACK CABLE AT JACK AND 3 FT OF SLACK CABLE AT RACK. FINAL TERMINATION TO BE COMPLETED BY THE OWNER/SECURITY CONSULTANT. 4 ICE MACHINE. ROUTE WIRING TO CONDENSER ON ROOF. COORDINATE WITH EQUIPMENT SUPPLIER. 5 PROVIDE NEW WIRING AND CONDUIT FOR VECTOR OVEN IN PLACE OF SPEED OVEN CIRCUIT. REPLACE EXISTING BREAKER IN PANEL WITH NEW BREAKER. 6 RELOCATE EXISTING DATA, SPEAKERS AND CAMERAS FOR CASHWRAP TO NEW LOCATIONS. COORDINATE EXACT LOCATIONS OF SPEAKERS AND CAMERS WITH OWNER. 7 EXISTING J-BOX IN WALL.VERIFY AND COORDINATE LOCATION AND TRENCH FROM J-BOX TO NEW POS EQUIPMENT. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 KEYED NOTES 8 PROVIDE DATA AND POWER OUTLET FOR FUTURE EQUIPMENT.COORDINATE EXACT LOCATIONS WITH ARCH. AND OWNER. 9 CONDUITS FOR EQUIPMENT POWER AND EMS LOW VOLTAGE. E.C. SHALL COORDINATE WITH CASEWORK MANUFACTURER FOR STUB-UP LOCATION. STUB-UP SHALL BE IN AN ACCESSIBLE SPACE IN THE CASEWORK. 10 E.C. SHALL REPLACE ALL OUTLETS ALONG FRONT WALL WITH TAMPER RESISTANT WHITE ONES AS REQUIRED. CONNECT BACK TO EXISTING CIRCUIT. 11 E.C. SHALL COORDINATE WITH CASEWORK MANUFACTURER FOR STUB-UP LOCATION. STUB-UP SHALL BE IN AN ACCESSIBLE SPACE IN THE CASEWORK. E.C. SHALL PROVIDE PULL STRING IN CONDUITS FOR FUTURE BEAN BEAN TO CUP MACHINES. 12 E.C. TO PROVIDE POWER AND LOW VOLTAGE PER MANUFACTURER REQUIREMENTS. 13 E.C. TO PROVIDE 208V/2P SWITCH FOR EACH WARMER INSIDE OF CABINET. 14 MOUNT OUTLET ABOVE DOOR. SPLICE AND EXTEND LOCAL CONVENIENCE CIRCUIT TO NEW OUTLET. 15 3/4" CONDUIT TO ABOVE T-GRID FOR EMS. 16 PROVISION FOR FUTURE EQUIPMENT AT 40" A.F.F. 17 PROVIDE NEW WIRING AND CONDUIT FOR FRESH FOOD CASE IN PLACE OF WARMING SHELF CIRCUIT. REPLACE EXISTING BREAKER IN PANEL WITH NEW BREAKER. 18 PROVIDE DATA AND POWER OUTLET IN CEILING FOR TV. COORDINATE EXACT LOCATION WITH OWNER. PROVIDE AND INSTALL ONE (1) 1" CONDUIT WITH FOUR (4) CAT-6 CABLES FROM JACK TO NETWORK RACK. LEAVE 18" OF SLACK CABLE AT JACK AND 3 FT OF SLACK CABLE AT RACK. FINAL TERMINATION TO BE COMPLETED BY THE OWNER/SECURITY CONSULTANT. 19 NEW EQUIPMENT TO REPLACE EXISTING CAPPUCCINO MACHINE. E.C. SHALL RUN NEW WIRE AND CONDUIT BACK TO EXISTING CIRCUIT. REPLACE EXISTING BREAKER IN PANEL WITH NEW BREAKER. UPSIZE AS NECESSARY 20 NEW EQUIPMENT TO REPLACE EXISTING TEA BREWER. E.C. SHALL RUN NEW WIRE AND CONDUIT BACK TO EXISTING CIRCUIT. REPLACE EXISTING BREAKER IN PANEL WITH NEW BREAKER. UPSIZE AS NECESSARY 01/20/23 SOC 109 OFFICE 105 DELI PREP 106 KITCHEN SERVICE 101 RETAIL T1 4 NOT IN SCOPE NOT IN SCOPE NOT IN SCOPE 2 2 3 1 2 1 1 1 1 110 30° BEER COOLER 108 -10° FREEZER 107 35° STOR. COOLER 106 KITCHEN SERVICE 101 RETAIL 104 EXIT HALLWAY 113 ELECTRICAL ROOM NOT IN SCOPE NOT IN SCOPE 5 3 6 6 6 6 6 6 6 6 6 T9 T9 T9 T9 T1 T1 T1B T1T1 T1 T1T1 T1 T1B T1 T1 T1B T1 T1B T1T1 115 35° BEVERAGE COOLER 112 STORAGE 114 STORAGE 2 2 2 2 22 2 22 2 2 2 2 2 2222 2 3 4 T11T11T11T11T11T11T11T11T11 NOT IN SCOPE 3 3 NOT IN SCOPE NOT IN SCOPE NOT IN SCOPE NOT IN SCOPE NOT IN SCOPE PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 9 / 2 0 2 3 9 : 4 6 : 2 6 A M ELECTRICAL LIGHTING PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 WCF KMD TYPE B REMODEL E3.02 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 SCALE:1/4" = 1'-0"1 ELECTRICAL LIGHTING PLAN KEYED NOTES 1 SEE DEMOLITION REFLECTED CEILING PLAN FOR LIGHTS BEING REMOVED IN AREA. 2 NEW LIGHT FIXTURES TO REPLACE EXISTING. SPLICE AND EXTEND EXISTING LIGHT CIRCUIT AND CONTROLS IN AREA TO NEW FIXTURES. 3 EXISTING TO REMAIN UNLESS OTHERWISE NOTED. 4 EMERGENCY EXIT SIGN EXISTING TO REMAIN 5 E.C. SHALL PROVIDE POWER FOR NEW LED PERIMETER LIGHTING AT THE FUEL CANOPY. COORDINATE WITH FUEL DRAWINGS FOR LIGHTING REQUIREMENTS. 6 REPLACE EXISTING CAN LIGHTS WITH NEW FIXTURE. SPLICE AND EXTEND EXISTING LIGHT CIRCUIT AND CONTROLS IN AREA TO NEW FIXTURES. N GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 EM 01/20/23 CONDENSING UNIT 21A (CUBE ICE MAKER #2) 340 LBS CONDENSING UNIT 18A (ICE MAKER #1) 325 LBS 3 3 1 2 4 PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 2 0 / 2 0 2 3 1 1 : 1 2 : 4 4 A M ELECTRICAL ROOF PLAN 2022020.40 FINAL DRAWINGS 01/20/2023 Author Approver E3.03 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 SCALE:1/4" = 1'-0"1 ELECTRICAL ROOF PLAN 1 EXTEND REMOVED CONDENSING UNIT CIRCUIT TO NEW CONDENSER LOCATION. VERIFY EXISTING WIRING AND BREAKER AND REPLACE AS NEEDED TO MATCH EQUIPMENT SCHEDULE. 2 CONDENSER (21A) POWERED VIA ICE MACHINE (21). SEE E3.00 FOR CIRCUITING AND E6.01 FOR CONDUIT AND WIRING SIZING. 3 EXISTING CONDENSER TO REMAIN 4 NEW GFI RECEPTACLE. SPLICE AND EXTEND EXISTING ROOFTOP RECEPTACLE CIRCUIT TO NEW RECEPTACLE. KEYED NOTES 01/20/23 E nsure receptacle is located so it will serv ice all rooftop eq uipment or add receptacle for eq uipment farther away. PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 9 / 2 0 2 3 9 : 4 6 : 2 7 A M ELECTRICAL SCHEDULES 2022020.40 FINAL DRAWINGS 01/20/2023 WCF KMD TYPE B REMODEL E6.00 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 ELECTRICAL EQUIPMENT CONNECTION SCHEDULE DEVICE NAME Count DESCRIPTION VOLTAGE EQUIPMENT LOAD APPARENT POWER Panel Circuit Number CIRCUIT BREAKE R SIZE WIRE SIZE BASE OFFSET 1 120 V 720 VA 3' - 6" 4 1 ICE/BEVERAGE DISPENSOR 120 V 15.0A 1800 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 4' - 0" 6 1 FOR PASTRY CASE 120 V 5.0A 600 VA A 66 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 8 3 DELI CASE 208 V 20.0A 4200 VA 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 10 1 FRI-JADO 208 V 15A 4400 VA 30A/2P #10, #10 GND, IN A 3/4" CONDUIT 3' - 1" 11 1 CAPPUCCINO MACHINE 120 V 15A 1800 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 1" 13 1 CONDIMENT DROP IN 120 V 5.0A 600 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 14 1 FOR MICROWAVE OVEN 120 V 13.4A 1000 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 15 1 HOT DOG ROLLER GRILL 120 V 15A 1800 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 16 1 NACHO MACHINE 120 V 2.5A 300 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 0" 18 1 ICE MAKER 120 V 2.5A 300 VA 15A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 18A 1 ICE MAKER CONDENSING UNIT 208 V 11A 3960 VA 30A/2P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 19 1 FOG MACHINE 120 V 8.2A 1000 VA B 71 15A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 20A 1 OVEN/PROOFER 208 V 29A 10440 VA 40A/3P #8, #10 GND, IN A 1" CONDUIT 1' - 6" 20D 1 EXHAUST HOOD FOR EQUIPMENT 20A 120 V 3.3A 396 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 21 1 ICE MAKER 208 V 13.9A 2891 VA B 35,37 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 21A 1 ICE MAKER CONDENSING UNIT (POWERED FROM 21) 208 V 1.5A 500 VA - #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 22 1 REFRIGERATED PREP UNIT 120 V 9A 1080 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 22 1 REFRIGERATED PREP UNIT 120 V 9A 1080 VA B 64 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 33 1 ICE CREAM MERCHANDISER 120 V 15.6 1872 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 42 4 POS STATION 120 V 2.5A 360 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 48 1 CREAMER DISPENSER 120 V 2.5A 360 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 1" 69 1 CUBELET ICE MACHINE 120 V 8.5A 1020 VA A 39 15A/1P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" 73 2 FROZEN CARBONATED BEV. 208 V 20.5A 4800 VA 30A/2P #10, #10 GND, IN A 3/4" CONDUIT 4' - 0" 74 2 FROZEN UNCARBONATED BEVERAGE 120 V 12A 1440 VA 15A/1P #12, #12 GND, IN A 3/4" CONDUIT 2' - 4" 93 1 F'REAL 208 V 6.5A 800 VA 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 4' - 0" 94 1 STEAMER WARMER 120 V 3A 720 VA B 69 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 3' - 6" 95 1 F'REAL 120 V 15.0A 1800 VA 20A/1P #12, #12 GND, IN A 3/4" CONDUIT 4' - 0" 101 1 VECTOR MULTI COOK OVEN 208 V 33A 11880 VA 50A/3P #6, #10 GND, IN A 1" CONDUIT 1' - 6" 101 1 VECTOR MULTI COOK OVEN 208 V 33A 11880 VA B 68,70,72 50A/3P #6, #10 GND, IN A 1" CONDUIT 1' - 6" 111 1 TORTILLA TOASTER 208 V 24.0A 4992 VA A 63,65 30A/2P #10, #10 GND, IN A 3/4" CONDUIT 1' - 6" 115 3 BEAN TO CUP 208 V 16.0A 3328 VA 20A/2P #12, #12 GND, IN A 3/4" CONDUIT 1' - 6" Lighting Fixture Schedule LIGHT FIXTURE NAME MANUFACTURER CATALOG NUMBER VOLTAGE VA PER FIXTURE MOUNTING FIXTURE DESCRIPTION T1 LSI LEDPN2X4 50W 4K SFPACK6 120 V 56 VA BOTTOM OF LENS EVEN WITH BOTTOM OF TRUSS EDGE LIT 2X4 LOW PROFILE LED, 4K, 4800 LUMENS, AIRCRAFT CABLE MOUNTED T1B LSI SAME AS T1 EXCEPT WITH 1400 LUMEN EMERGENCY BATTERY 120 V 56 VA BOTTOM OF LENS EVEN WITH BOTTOM OF TRUSS T4 LSI WNA10 LED SS NW UE 120 V 48 VA SURFACE SURFACE WRAP 3"X10"X48" ACRYLIC PRISMATIC DIFFUSER WHITE ENDPLATES LED 5200 LUMENS, 4K T4B LSI SAME AS T4 EXCEPT 6300 LUMENS 120 V 48 VA SURFACE T9 LSI LAD6 18 40 UE TR6RL 120 V 18 VA RECESSED RECESSED LED DOWNLIGHT 6" APERTURE, 1000 LUMENS, 4K T11 LSI LAD8 LED 42L UNV DIM1 40 80CRI WF 120 V 42 VA RECESSED RECESSED LED DOWNLIGHT 8" APERTURE, 3259 LUMENS, 4K EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 NOTES: 1. NEW EQUIPMENT WITH PANEL AND CIRCUIT NUMBERS SHOWN AS EXISTING ARE TO REUSE EXISTING CIRCUIT BREAKERS OF EQUIPMENT REMOVED. E.C. SHALL PROVIDE NEW FEEDERS AND CONDUITS BACK TO EXISTING PANELS AND REPLACE ANY BREAKERS REQUIRED. EXISTING EXISTING EXISTING EXISTING POWERED BY 18A EXISTING EXISTING EXISTING 01/20/23 MPAD MOUNTED XFMR MDP - MAIN DISTRIBUTION CENTER 800A MLO, 120/208V, 3PH, 4W, NEMA 3R, 65KAIC PANEL 'A' 200A 3P GROUND PER NEC ARTICLE 250 01G PANEL 'B'PANEL 'M1'PANEL 'D' PANEL 'C' 200A 3P 200A 3P 200A 3P PANEL 'L1' PROJECT NUMBER: SHEET NUMBER SHEET NAME DRAWN BY:APPROVED BY: DRAWING ISSUE PROTOTYPE VERSION: ISSUANCE DESCRIPTION DATE ARCHITECT/ENGINEER: STAMP: 185 S. State Street | Salt Lake City, Utah 84111 THESE PLANS ARE SUBJECT TO FEDERAL COPYRIGHT LAWS: ANY USE OF SAME WITHOUT THE EXPRESSED WRITTEN PERMISSION OF MAVERIK, INC IS PROHIBITED. 2018 MAVERIK, INC. 1/ 1 9 / 2 0 2 3 9 : 4 6 : 2 7 A M PANEL SCHEDULES 2022020.40 FINAL DRAWINGS 01/20/2023 WCF KMD TYPE B REMODEL E6.01 MA V E R I K , I N C . 85 9 W E S T M A I N S T R E E T RE X B U R G , I D 8 3 4 4 0 MA V E R I K C - S T O R E # 5 0 5 CONTRACTOR IS RESPONSIBLE FOR LOADING ON ALL PANELS PER THE N.E.C. CONTRACTORS SHALL KEEP CIRCUIT CONTINUITY TO DEVICES TO REMAIN. E.C. SHALL VERIFY THAT ALL LOADS ON EXISTING PANELS AND FEEDERS DO NOT EXCEED THE MAXIMUM LOAD REQUIRED PER THE LATEST EDITION OF THE N.E.C. NOTIFY A/E IF OVERLOAD IS POSSIBLE. ONLY PANELS WITH ADDITION NEW LOADS ARE SHOWN. BESIDES VERIFYING THAT THE NEW LOADS DO NOT OVERLOAD EXISTING PANELS AND FEEDERS, THE CONTRACTOR IS ALSO RESPONSIBLE TO CALCULATE AND VERIFY THAT ALL UPSTREAM PANELS AND FEEDERS ARE NOT OVERLOADED DUE TO THE NEW LOADS. CONTRACTOR SHALL NOTIFY ENGINEER OF LOAD CALCULATIONS PRIOR TO COMMENCING WORK. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY AND CALCULATE SHORT CIRCUIT FAULT CURRENT AND ARC FLASH AND PROVIDE LABELS ON EQUIPMENT PER N.E.C. AND LOCAL JURISDICTION. CONRACTOR SHALL PROVIDE EQUIPMENT RATED FOR FAULT CURRENT. ALL DEVICES REMOVED DURING DEMOLITION SHALL HAVE ALL ASSOCIATED CONDUIT, WIRING, AND CONTROLS REMOVED BACK TO SOURCE OR NEXT DEVICE THAT REMAINS. SCALE:N.T.S1EXISTING POWER RISER DIAGRAM GPD GROUP Professional Corporation AKRON, OH 44311 520 S. MAIN STREET, STE 2531 1. BOLD INDICATES NEW CIRCUIT. PROVIDE NEW CIRCUIT BREAKERS AS NEEDED. NEW CIRCUIT BREAKERS SHALL MATCH EXISTING TYPE AND AIC. 2. E.C. SHALL REPLACE ANY EXISTING BREAKERS REUSED FOR NEW EQUIPMENT WITH GFCI BREAKERS AS REQUIRED PER CODE. Notes: Total Est. Demand Current:20 A Total Conn. Current:26 A Total Est. Demand:7275 VA Kitchen Equipment 5592 VA 65.00%3635 VA Total Conn. Load:9232 VA Power 3640 VA 100.00%3640 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps:2 A 39 A 47 A Total Load:180 VA 4056 VA 4996 VA 71 FUTURE HEATED SHELF 20 A 1 950 VA 950 VA 1 20 A FUTURE HEATED SHELF 72 69 Space -- 1 -- 540 VA 1 20 A TV MONITOR 70 67 Space -- 1 -- 180 VA 1 20 A BOH CONVENIENCE 68 65 ---- --2496... 600 VA 1 20 A PASTRY CASE (6)66 63 TORTILLA TOASTER (111) (5mA GFCI) 30 A 2 2496... 0 VA -- -- --64 61 EQUIPMENT 20 A 1 0 VA 0 VA 2 50 A EQUIPMENT 62 59 ---- --0 VA 0 VA -- -- --60 57 ---- -- 0 VA 0 VA 2 50 A EQUIPMENT 58 55 EQUIPMENT 25 A 3 0 VA 0 VA -- -- --56 53 ---- --0 VA 0 VA 2 20 A EQUIPMENT 54 51 ---- -- 0 VA 0 VA 1 20 A EQUIPMENT 52 49 EQUIPMENT 40 A 3 0 VA 0 VA 1 20 A EQUIPMENT 50 47 ---- --0 VA 0 VA 1 20 A EQUIPMENT 48 45 ---- -- 0 VA 0 VA 1 20 A EQUIPMENT 46 43 EQUIPMENT 40 A 3 0 VA 0 VA 1 20 A EQUIPMENT 44 41 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 42 39 ICE DISPENSER (69) (5mA GFCI)20 A 1 1020... 0 VA 1 20 A EQUIPMENT 40 37 ---- -- 0 VA 0 VA 1 20 A EQUIPMENT 38 35 EQUIPMENT 30 A 2 0 VA 0 VA 1 20 A EQUIPMENT 36 33 ---- -- 0 VA 0 VA 1 20 A EQUIPMENT 34 31 EQUIPMENT 30 A 2 0 VA 0 VA 1 20 A EQUIPMENT 32 29 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 30 27 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 28 25 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 26 23 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 24 21 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 22 19 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 20 17 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 18 15 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 16 13 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 14 11 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 12 9 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 10 7 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 8 5 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 6 3 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 4 1 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure:NEMA 1 MCB Rating: Mounting:SURFACE Wires:4 Mains Rating:225 A Supply From:Phases:3 Mains Type:MLO Location:ELECTRICAL ROOM 113 Volts:120/208 Wye A.I.C. Rating:EXISTING Branch Panel: A LOAD SUMMARY TOTAL LOAD CHANGE TOTAL LOAD BEING ADDED = 30530 VA ESTIMATED CURRENT ADDED = 85 A EXISTING LOAD (PER EXISTING DRAWINGS) PANEL A = VERIFY IN FIELD PANEL B = VERIFY IN FIELD EXISTING TOTAL LOAD (PER 12 MONTH PEAK DEMAND) PEAK KW = 71.7 KW NEW LOAD PER PANEL PANEL A = VERIFY IN FIELD PANEL B = VERIFY IN FIELD NEW TOTAL LOAD (ADDED LOAD + (PEAK*1.25)) NEW TOTAL LOAD = 119275 VA NEW TOTAL CURRENT = 332 A 1. BOLD INDICATES NEW CIRCUIT. PROVIDE NEW CIRCUIT BREAKERS AS NEEDED. NEW CIRCUIT BREAKERS SHALL MATCH EXISTING TYPE AND AIC. 2. E.C. SHALL REPLACE ANY EXISTING BREAKERS REUSED FOR NEW EQUIPMENT WITH GFCI BREAKERS AS REQUIRED PER CODE. Notes: New Est. Demand Current:39 A New Conn. Current:50 A Kitchen Equipment 11880 VA 65.00%7722 VA New Demand:13953 VA Receptacle 1000 VA 100.00%1000 VA New Conn. Load:18111 VA Power 5231 VA 100.00%5231 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps:47 A 48 A 57 A Total Load:5586 VA 5760 VA 6766 VA 71 FOG (19)15 A 1 1000... 3960... -- -- --72 69 STEAMER (94)20 A 1 720 VA 3960...-- -- --70 67 ---- -- 0 VA 3960...3 50 A VECTOR OVEN (101) (5mA GFI)68 65 EQUIPMENT 30 A 2 0 VA 360 VA 1 20 A FUTURE USE 66 63 ---- -- 0 VA 1080...1 20 A REFRIGERATED PREP UNIT (22)64 61 EQUIPMENT 30 A 2 0 VA 180 VA 1 20 A TORTILLA TABLE 62 59 EQUIPMENT 20 A 1 0 VA 0 VA -- -- --60 57 EQUIPMENT 20 A 1 0 VA 0 VA -- -- --58 55 ---- -- 0 VA 0 VA 3 50 A SWITCHED OFF 56 53 EQUIPMENT 20 A 2 0 VA 0 VA -- -- --54 51 EQUIPMENT 20 A 1 0 VA 0 VA -- -- --52 49 EQUIPMENT 20 A 1 0 VA 0 VA 3 30 A SWITCHED OFF 50 47 EQUIPMENT 20 A 1 0 VA 0 VA -- -- --48 45 EQUIPMENT 20 A 1 0 VA 0 VA -- -- --46 43 EQUIPMENT 20 A 1 0 VA 0 VA 3 30 A EQUIPMENT 44 41 EQUIPMENT 20 A 1 0 VA 0 VA -- -- --42 39 EQUIPMENT 20 A 1 0 VA 0 VA 2 20 A EQUIPMENT 40 37 ------ 1446... 0 VA -- -- --38 35 ICE MAKER (21)20 A 2 1446... 0 VA 2 20 A EQUIPMENT 36 33 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 34 31 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 32 29 ---- --0 VA 0 VA 1 20 A EQUIPMENT 30 27 EQUIPMENT 30 A 2 0 VA 0 VA 1 20 A EQUIPMENT 28 25 ---- -- 0 VA 0 VA 1 20 A EQUIPMENT 26 23 EQUIPMENT 30 A 2 0 VA 0 VA 1 20 A EQUIPMENT 24 21 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 22 19 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 20 17 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A SWITCHED OFF 18 15 SWITCHED OFF 15 A 1 0 VA 0 VA 1 20 A EQUIPMENT 16 13 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 14 11 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 12 9 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 10 7 EQUIPMENT 20 A 1 0 VA 0 VA 1 20 A EQUIPMENT 8 5 EQUIPMENT 20 A 1 0 VA 0 VA 1 30 A SWITCHED OFF 6 3 EQUIPMENT 20 A 1 0 VA 0 VA -- -- --4 1 EQUIPMENT 20 A 1 0 VA 0 VA 2 30 A EQUIPMENT 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes: Enclosure:NEMA1 MCB Rating: Mounting:SURFACE Wires:4 Mains Rating:225 A Supply From:Phases:3 Mains Type:MLO Location:ELECTRICAL ROOM 113 Volts:120/208 Wye A.I.C. Rating:EXISTING Branch Panel: B 01/20/23