Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED FA SUBMITTAL & DRAWINGS - 23-00022 - BYUI Hart - Physical Treatment Center Remodel
Author Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : BYUI Hart - Physical Treatment Center Remodel Address : 285 S 1st W Record Type : Commercial - Remodel Document Filename : FA SUBMITTAL & DRAWINGS - 23-00022 - BYUI Hart - Physical Treatment Center Remodel.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00022 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 11 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector Pg 17 Stamp Alex Owens : Electrical Open 17 Approved - Electrical Inspector Pg 17 Free Text Alex Owens : Electrical Open 17 All electrical work to comply with 2017 NEC Commercial - Remodel Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 Hart Building ASI 8 – BYU Idaho 306 South 1st West Rexburg, ID. 83440 Hart Building ASI 8 BYU Idaho Fire Alarm System Submittal & Drawings PROJECT Equipment Manufacturer: Gamewell-FCI Hart Building ASI 8 Authorized Distributor: Nelson Fire Systems BYU Idaho 1481 S Major St Fire Alarm System SLC, UT 84115 801-468-8300... Hart Building ASI 8 – BYU Idaho 306 South 1st West Rexburg, ID. 83440 TABLE OF CONTENTS Data Sheet Part No. Description FACU: (Existing) Gamewell-FCI E3 Series Emergency Evacuation System NAC POWER SUPPLY: (Existing) Gamewell-FCI HPF-PS10 NAC Power Supply w/Internal Sync Module DEVICES: Gamewell-FCI SPCWL White Speaker Only – Ceiling Mount Gamewell-FCI SPSCWL White Speaker/Strobe – Ceiling Mount Battery Calculations E3 System Battery Calc HPFF8 Battery Calc CKT Voltage Drops Drawings Sheet No. Description Cover Page FA-C-01 Fire Alarm Cover Riser Diagram FA-R-01 Fire Alarm Riser and Matrix Level 1 FA-1-01 Notification Circuits Devices Ceiling Speaker Strobes L Series, Indoor Ceiling Strobes and Dual Speakers Indoor Output Speaker Strobes and Dual Speakers for Ceiling Applications Notification Appliances General The L-Series indoor selectable-output speaker strobes and dual-voltage evacuation speakers offer a modern, aesthetic plug-in design that reduce costly ground faults. The universal mounting plate can be used in ceiling applications and its flexible design enables the Installer to easily perform the following: • Pre-wire mounting plates •Dress the wires Confirm wiring continuity before the Installer plugs-in the speakers. In addition, this product includes a protective plastic cover which shields exposed speaker components and prevents nicked wires. These devices enable faster installations by providing instant feedback to the Installer to ensure the following: • The wiring is properly connected. • The rotary switches are set to the selected voltage and power settings. • The 7 field-selectable candela settings are configured for wall speaker strobes. • The low total harmonic distortion of the SP speaker offers both high-fidelity and high-volume sound output so that it can be used in high ambient noise applications. L-Series makes installation easy to install the L-Series speakers or speaker strobe, do the following: 1. Attach a universal mounting plate to a 4 x 4 x 2 1/8 inch backbox. Flush- mount applications do not require an extension ring. 2. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. 3. To attach the speaker or speaker strobe to the mounting plate, insert the product tabs into the mounting plate grooves. 4. Hinge the device into position to lock the product pins into the mounting plate terminals. 5. A catch temporarily holds the device in place until you secure the device with a captured mounting screw. FEATURES & BENEFITS • Includes a plug-in feature and protective cover to reduce ground faults • Contains a universal mounting plate with an on-board shorting spring that is used to test the wiring continuity before an installation • No extension ring required • Field-selectable candela settings on ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 • Uses an automatic selection of 12- or 24- volt operation at 15 and 30 candela • Provides a rotary switch that simplifies the field selection of speaker voltage (25) and 70.7 VRMS) and the following power settings: - 1/4 watt - 1/2 watt - 1 watt - 2 watts • Offers speakers with both high-fidelity and high-volume sound output • Compatible with the System Sensor synchronization protocol • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products •Designed with a tamper-resistant construction • Built with an updated modern design 2 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General The L-Series speaker and speaker strobes shall mount to a 4 x 4 x 2 1/8-inch backbox. A universal mounting plate shall be used for the mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, the L-Series speaker strobes, when used with the Sync•Circuit. Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When these devices are used with the Sync•Circuit Module, either of the following may occur. • 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32° F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have the following field-selectable candela settings: Speaker The speaker shall be an L-Series model _______ dual- voltage transformer speaker capable of operating at 25.0 or 70.7 nominal VRMS. It should be listed to UL Standard 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe Combination The speaker strobe shall be an L-Series model __________ listed to UL Standard 1480 and UL Standard 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal VRMS selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. UL Current Draw Data Table 1 lists the UL maximum strobe current draw. Table 2 lists the ceiling mount speaker sound outputs. Table 3 lists the ceiling-mount speaker strobe sound outputs. •15 •30 •75 •95 •115 •150 •177 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Table 1 UL Max. Strobe Current Draw (mA RMS) Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Table 2 Ceiling Speaker Sound Outputs Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 Table 3 Ceiling-Mount Speaker Strobe Sound Output 3 Dimensions Figure 1 shows the speaker dimensions. Figure 2 shows the speaker dimensions. Surface Mounting Figure 3 illustrates the ceiling-mount speaker and speaker strobes with the SBBCR/SBBCWL surface mount backbox. L-Series Ordering Information SpectrAlert Speakers and Strobes: Ceiling Mount: SPCWL: White Speaker only SPCRL: Red Speaker only SPSCWL: White Speaker Strobe SPSCRL: Red Speaker Strobe SPSCWL-P: Plain, Speaker Strobe SPSCWL-SP: Fuego, Speaker Strobe SPSCWL-CLR-ALERT : Alert, Speaker Strobe,Clear Lens Accessories: SBBCWL: White, Universal Ceiling Surface Mount Back Box SBBCRL: Red, Universal Ceiling Surface Mount Back Box TRC-2W: White, Universal Ceiling Trim Ring TRC-2: Red, Universal Ceiling Trim Ring Figure 1 Speaker Dimensions Figure 2 Speaker Dimensions Figure 3 Ceiling-Mount Speaker and Speaker Strobe with SBBCRL/SBBCWL Surface Mount Backbox L Series, Indoor Ceiling Strobes and Dual Speakers Technical Specifications 9021-60930 | C | 03/18 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s L Series, Indoor Ceiling Strobes and Dual Speakers and other products available by visiting www.Gamewell-FCI.com SYSTEM Electrical/Operating Specifications: Nominal Voltage (speakers): 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers): 50 VDC Strobe Flash Rate: 1 flash per second Nominal Voltage (strobes): Regulated 12 VDC or Regulated 24 VDC/FWR Operating Voltage Range (includes fire alarm panels with built-in sync): 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module: 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range: Frequency Range: 400 to 4,000 Hz Power: ¼, ½, 1, 2 watts STANDARDS The L-Series, Indoor Ceiling Strobes and Horn Strobes are designed to comply with the following standard: UL Standard: UL 1971 and UL 464 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S5512, S4011 CSFM: 7320-1653:0505 ISO 9001 Certification Physical Specifications: Operating Temperature:32°F to 120°F (0°C to 49°C) Humidity Range:10 to 93% non-condensing Dimensions,Ceiling-Mount:Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount BacKbox 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Backbox 6.9 in, 176 mm 5.37 in,136 mm Calculations BYUi Hart -Battery Calculation Report PANEL INFORMATION Panel Type HPFF8 No. of Loops 0 No. of Devices Status 0 PASS BATTERY & CHARGER REQUIREMENT Normal Operation 24 Hours BAT-12120 12Ah 7.951Ah In 5 Mins Suggested Battery Suggested Capacity Required Capacity Suggested Batt. Box Alarm Alarm Load Stan dby/Quiescent Load Standby Load Current 0.274 x Panel in Normal Operation (In hours) In Alarm Load Current(ln Amps)x Panel In Alarm(ln Hours) 24 = 6.576Ah 0.603 0.083(5mins) = 0.0SAh Total Current Load 6.626Ah Multiply with derating factor= x 1.2 Adding with spare capacity N/A TotalAH required PANEL MO OU LES & CIRCUITS 877 mA Consumed No. of Modules & 3 Circuits 0% Modlfe Name Quantity Quiescent/Stand By (mA) Alanna (mA) MAIN CIRCUIT BOARD WITH 4.7K EOLR INSTALLED 139 157 ZNAC-PS Class A card 135 142 NAC CIRCUITS NACName Alarms(mA) QuiescenVStand By (mA) NAC Circuit 1 304 0 NAC Circuit 2 0 0 NAC Circuit 3 0 0 NAC Circuit 4 0 0 NAC Circuit 5 0 0 BATTERY SHARING Battery Sharing Alarms (mA) QuiescenVStand By (mA) Battery Sharing 1 0 0 Battery Sharing 2 0 0 Battery Sharing 3 0 0 = 7.951Ah 100% Drawings B Y U - I D A H O H A R T B U I L D I N G - A S I 8 F I R E A L A R M S Y S T E M J P K P A Y N E T D T ( A R C H E ) 1 / 1 6 " = 1 ' X X X X X X X X BYU - IDAHO HART BUILDING - ASI 8 306 SOUTH 1st WEST REXBURG, IDAHO 83440 FIRE ALARM SYSTEM P R O J E C T C O V E R S H E E T F A - C - 0 1 N E L S O N F I R E S Y S T E M S D R A W N B Y : D E S I G N E D B Y : A P P R O V E D B Y : D A T E : S C A L E : P R O J E C T N O : R E V I S I O N N O : D R A W I N G N A M E : NOTE: NFS DRAWINGS ARE BASED ON THE PROJECT ARCHITECTURE/ENGINEER (A/E) PLANS AND SPECIFICATIONS FURNISHED TO NFS. A/E IS SOLELY RESPONSIBLE (NOT NFS) FOR THE TYPE, SIZE, LOCATION, AND SUITABILITY OF ALL FIRE ALARMS, CONTROL PANELS, AND OTHER DEVICES SHOWN ON THE A/E PLANS. NFS DRAWINGS ARE TO SHOW ONLY THE WIRING DIAGRAMS BETWEEN FIRE ALARM DEVICES AND CONTROL PANELS. NFS IS NOT RESPONSIBLE FOR THE INFORMATION SHOWN ON THE A/E PLANS. N E L S O N F I R E S Y S T E M S P A G E : B Y U - I H A R T A S I 8 C . D W G 2 / 1 4 / 2 0 2 3 INDEX OF DRAWINGSPAGE123FA-C-01FA-R-01FA-1-01 SHEET #LEVELPROJECT COVER SHEET / I N D E X O F D R A W I N G S FIRE ALARM BUILDING RIS E R D I A G R A M / M A T R I X LEVEL 1DEVICE SCHEDULECOUNTSSPEAKER/STROBE- CEILING S P S C W L DESCRIPTIONFIRE ALARM CONTROL UNIT E X I S T I N G TRANSPONDER PANEL E X I S T I N G SSFACUTRANC 4 S Q . 2 - 1 / 8 " D E E P B O X M I N I M U M w / 1 - 1 / 2 " E X T . R I N G E X I S T I N G T O R E M A I N E X I S T I N G T O R E M A I N P A R T N U M B E R M O U N T I N G R E Q U I R E M E N T SYMBOL4 SHEET CONTENTSNOTIFICTATION CIRCUITSSPEAKER ONLY- CEILING S P C W L SC 4 S Q . 2 - 1 / 8 " D E E P B O X M I N I M U M w / 1 - 1 / 2 " E X T . R I N G 3 BUILDING CONSTRUCTION TYPE: IIBBUILDING SQUARE FOOTAGE: 3,297 FT 2 A D D E D O R R E M O V E D D E V I C E S ( A D J U S T M E N T A C C O U N T E D F O R I N C O U N T S A B O V E ) D E S C R I P T I O N C O U N T S S Y M B O L A D D E D S P E A K E R / S T R O B E - C E I L I N G 2 S S A D D E D S P E A K E R O N L Y - C E I L I N G 3 S C C LEVEL 1 D O N O T U S E S H I E L D E D W I R E O N A D D R E S S A B L E C I R C U I T J P K P A Y N E T D T ( A R C H E ) 1 / 1 6 " = 1 ' X X X X X X X X BYU - IDAHO HART BUILDING - ASI 8 FIRE ALARM RISER DIAGRAM / MATRIX 306 SOUTH 1st WEST REXBURG, IDAHO 83440 FIRE ALARM SYSTEM F I R E R I S E R D I A G R A M / M A T R I X F A - R - 0 1 N E L S O N F I R E S Y S T E M S D R A W N B Y : D E S I G N E D B Y : A P P R O V E D B Y : D A T E : S C A L E : P R O J E C T N O : R E V I S I O N N O : D R A W I N G N A M E : NOTE: NFS DRAWINGS ARE BASED ON THE PROJECT ARCHITECTURE/ENGINEER (A/E) PLANS AND SPECIFICATIONS FURNISHED TO NFS. A/E IS SOLELY RESPONSIBLE (NOT NFS) FOR THE TYPE, SIZE, LOCATION, AND SUITABILITY OF ALL FIRE ALARMS, CONTROL PANELS, AND OTHER DEVICES SHOWN ON THE A/E PLANS. NFS DRAWINGS ARE TO SHOW ONLY THE WIRING DIAGRAMS BETWEEN FIRE ALARM DEVICES AND CONTROL PANELS. NFS IS NOT RESPONSIBLE FOR THE INFORMATION SHOWN ON THE A/E PLANS. N E L S O N F I R E S Y S T E M S P A G E : B Y U - I H A R T A S I 8 R . D W G 2 / 1 4 / 2 0 2 3 EXISTINGFACU E X I S T I N G T R A N S P O N D E R EXISTINGBATTERYCABINET L O C A T E D I N E L E C T R I C A L R O O M EXISTING ADDRESSABLE DEVICESLOSS OF POWER ANY PANEL OR NACLOW BATTERY CONDITIONSOPEN CIRCUIT CONDITIONSGROUND FAULTS FACPANNUNCIATIONNOTIFICATIONFIRESAFETY CONTROLREPORTINGSYSTEM INPUTS SYSTEM OUTPUTSFIRE ALARMINPUT/OUTPUT MATRIXALARM SIGNAL TO FIRE ALARM DISPLAYSUPERVISORY SIGNAL TO FIRE ALARM DISPLAYTROUBLE SIGNAL TO FIRE ALARM DISPLAYBUILDING NOTIFICATIONHVAC SHUT-DOWNFIRE/SMOKE DAMPERSRELEASE MAGNETIC DOOR HOLDERSALARM SIGNAL TO MONITORING COMPANYSUPERVISORY SIGNAL TO MONITORING COMPANYTROUBLE SIGNAL TO MONITORING COMPANY 1 / 2 W 1 / 2 W S P 1 - 3 1 / 2 W 1 / 2 W S P 1 - 1 1 / 2 W S P 1 - 2 1 / 2 W S P 1 - 6 1 / 2 W S P 1 - 7 S P 1 - 5 S P 1 - 4 1 P A I R # 1 4 ' S T W I S T E D S H I E L D E D S P E A K E R C I R C U I T L 1 - 1 7 5 c d L 1 - 2 7 5 c d L 1 - 3 1 5 c d L 1 - 4 1 5 c d S T R O B E C I R C U I T S 2 # 1 4 ' S S S C S S C S S C S S C S C S C S C ( 4 T W I S T S P E R F O O T ) [ S P C W L ] C E I L I N G S P E A K E R O N L Y T O N E X T D E V I C E S P E A K E R C K T O U T I N [ S P S C W L ] C E I L I N G S P E A K E R S T R O B E T O N E X T D E V I C E S P E A K E R C K T O U T I N T O N E X T D E V I C E ( + ) ( - ) S T R O B E C I R C U I T I N O U T ( + ) ( - ) D E V I C E L E G E N D F A C U F I R E A L A R M C O N T R O L U N I T - E X I S T I N G T R A N T R A N S P O N D E R - E X I S T I N G D E S C R I P T I O N C O U N T S S Y M B O L S S P E A K E R O N L Y - C E I L I N G 3 C S S S P E A K E R / S T R O B E - C E I L I N G 4 C E X I S T I N G D E V I C E ( E ) U P D N E L E V A T O R 1 V E L E V A T O R L O B B Y 1 W S T A I R W E L L 1 Z H A L L W A Y 1 X V E S T I B U L E 1 Y S T I A R W E L L I - U M E C H A N I C A L R O O M 1 1 8 H A L L W A Y 1 - P S T O R A G E 1 5 4 A H A L L W A Y 1 - K T E L E C O M R O O M 1 6 9 C U S T O D I A L R O O M 1 4 7 S T A I R W E L L 1 - Q H A L L W A Y 1 - R H A L L W A Y 1 - T U N A S S I G N E D R O O M 1 4 3 U N A S S I G N E D 1 4 1 R A M P 1 - S H A L L W A Y 1 - M S T O R A G E 1 4 1 A S T A I R W E L L 1 - C C U S T O D I A L 1 9 0 C L A S S R O O M A R E A 1 8 2 F H A L L W A Y 1 - D S M A L L C O M B I N E D E Q U I P M E N T A R E A 1 8 2 G F I T N E S S C E N T E R 1 8 2 V E S T I B U L E 1 - G C A R D I O A R E A 1 8 2 A S P I N N I N G A R E A 1 8 2 B M A C H I N E W E I G H T S A R E A C I R C U I T T R A I N I N G 1 8 2 C F R E E W E I G H T A R E A 1 8 2 E H A L L W A Y 1 - B S T R E T C H I N G A R E A 1 8 2 D S T A I R W E L L 1 - A E Q U I P . S T O R A G E 1 8 2 A S T O R A G E 1 9 8 E L E V . E Q U I P . 1 9 7 E L E C . / M E C H . 1 9 9 C O U R T # 1 1 9 1 C O U R T # 2 1 9 2 C O U R T # 3 1 9 3 C O U R T # 4 1 9 4 C O U R T # 5 1 9 5 U N A S S I G N E D R O O M 1 4 8 U N A S S I G N E D R O O M 1 4 6 C L A S S R O O M 1 5 4 C L A S S R O O M 1 7 0 U P D O W N R A M P D O W N D O W N R A M P U P U P R A M P U P U P POOL SERVICE130 T R A N L E V E L 1 F A C U J P K P A Y N E T D T ( A R C H E ) 1 / 1 6 " = 1 ' X X X X X X X X BYU - IDAHO HART BUILDING - ASI 8 306 SOUTH 1st WEST REXBURG, IDAHO 83440 FIRE ALARM SYSTEM L E V E L 1 N O T I F I C A T I O N F A - 1 - 0 1 T O T R A N S P O N D E R L O C A T E D I N E L E C T R I C A L R O O M S Y S E T M N O T E S : 25'10'50' W E S N 1 N E L S O N F I R E S Y S T E M S 8 0 1 - 4 6 8 - 8 3 0 0 D R A W N B Y : D E S I G N E D B Y : A P P R O V E D B Y : D A T E : S C A L E : P R O J E C T N O : R E V I S I O N N O : D R A W I N G N A M E : NOTE: NFS DRAWINGS ARE BASED ON THE PROJECT ARCHITECTURE/ENGINEER (A/E) PLANS AND SPECIFICATIONS FURNISHED TO NFS. A/E IS SOLELY RESPONSIBLE (NOT NFS) FOR THE TYPE, SIZE, LOCATION, AND SUITABILITY OF ALL FIRE ALARMS, CONTROL PANELS, AND OTHER DEVICES SHOWN ON THE A/E PLANS. NFS DRAWINGS ARE TO SHOW ONLY THE WIRING DIAGRAMS BETWEEN FIRE ALARM DEVICES AND CONTROL PANELS. NFS IS NOT RESPONSIBLE FOR THE INFORMATION SHOWN ON THE A/E PLANS. N E L S O N F I R E S Y S T E M S P A G E : 1 . I N S T A L L A T I O N S H A L L C O M P L Y W I T H N E C , N F P A 7 2 A N D O T H E R A P P L I C A B L E C O D E S A S R E Q U I R E D B Y T H E L O C A L A H J . C L A S S " B " W I R I N G I S R E Q U I R E D . 2 . W I R I N G D E P I C T E D O N T H E S E P L A N I S S C H E M A T I C - A C T U A L W I R E L O C A T I O N S M A Y D I F F E R F R O M T H E S E P L A N S . W I R I N G S H A L L B E P E R F O R M E D A S A C T U A L B U I L D I N G C O N S T R U C T I O N C O N D I T I O N A L L O W A N D T O M I N I M I Z E P E N E T R A T I O N S T H R O U G H A R E A S E P A R A T I O N W A L L S A N D F I R E W A L L S . T H E U S E O F A R A C E W A Y I S P E R M I T T E D A S L O N G A S N O 1 1 0 V O R H I G H E R C A B L E S A R E I N T H E R A C E W A Y . 3 . P O W E R - L I M I T E D ( P L ) A N D N O N P O W E R - L I M I T E D ( N P L ) C K T W I R I N G M U S T R E M A I N S E P A R A T E D I N C A B I N E T . A L L P L C K T W I R I N G M U S T R E M A I N A T L E A S T 0 . 2 5 " A W A Y F R O M A N Y N P L C K T . F U R T H E R M O R E , A L L P L A N D N P L C K T W I R I N G M U S T E N T E R A N D E X I T T H E C A B I N E T T H R O U G H A D I F F E R E N T K N O C K O U T A N D / O R S E P A R A T E C O N D U I T . 4 . O N L Y F I R E A L A R M W I R I N G I S P E R M I T T E D I N F I R E A L A R M C O N D U I T . D O N O T U S E 1 1 0 V O R H I G H E R I N F I R E A L A R M C O N D U I T . 5 . S M O K E D E T E C T O R S S H A L L B E I N S T A L L E D A N D C O V E R E D U N T I L T E S T I N G A N D F I N A L I N S P E C T I O N A R E C O M P L E T E D . D O N O T I N S T A L L S M O K E D E T E C T O R S U N T I L B U I L D I N G I S C L E A N . 6 . L O C A T E S M O K E D E T E C T O R S A M I N I M U M O F T H R E E ( 3 ) F E E T F R O M M E C H A N I C A L D I F F U S E R S . 7 . D O N O T U S E S H I E L D E D W I R E O N A D D R E S S A B L E C K T S . 8 . A S M O K E D E T E C T O R M U S T B E I N E V E R Y R O O M W I T H A F I R E A L A R M C O N T R O L U N I T O R P O W E R S U P P L Y . 9 . F I R E A L A R M C K T S N E E D T O B E F R E E O F G R O U N D S , F A U L T S , A N D S H O R T S P R I O R T O C O N N E C T I O N T O F I R E A L A R M E Q U I P M E N T . 1 0 . D E D I C A T E D 1 2 0 V A C C K T S S H A L L B E M A R K E D A S " F I R E A L A R M C K T " A N D B E A C C E S S I B L E O N L Y T O P E R S O N N E L . D I S C O N N E C T S F O R T H E S E C K T S W I L L B E R E D I N C O L O R A N D T H E I R L O C A T I O N W I L L B E N O T E D A T E A C H C O N T R O L U N I T . 1 1 . W H E N M O R E T H A N T W O V I S U A L N O T I F I C A T I O N A P P L I A N C E S A R E I N T H E S A M E R O O M O R A D J A C E N T S P A C E W I T H I N T H E F I E L D O F V I E W , T H E Y S H A L L B E S Y N C H R O N I Z E D . 1 2 . B U I L D I N G C O N S T R U C T I O N T Y P E : I I B 1 2 . 1 . M A I N T A I N P A T H W A Y S U R V I V A B I L I T Y L E V E L 0 G E N E R A L N O T E S : B Y U - I H A R T A S I 8 . D W G 2 / 1 4 / 2 0 2 3 D E V I C E L E G E N D S S S P E A K E R / S T R O B E - W A L L F A C U F I R E A L A R M C O N T R O L U N I T - E X I S T I N G T R A N T R A N S P O N D E R - E X I S T I N G D E S C R I P T I O N C O U N T S S Y M B O L S S P E A K E R O N L Y - C E I L I N G 3 A D D E D O R R E M O V E D D E V I C E S ( A D J U S T M E N T A C C O U N T E D F O R I N C O U N T S A B O V E ) D E S C R I P T I O N C O U N T S S Y M B O L W I R E S C H E D U L E N O T E D E S C R I P T I O N W I R E S S L S P E A K E R C I R C U I T 1 P A I R # 1 4 ' S T W I S T E D / S H I E L D E D S T R O B E C I R C U I T 2 # 1 4 ' S W I R I N G N O T E D E S C R I P T I O N A = 2 T O T A L C O N D U C T O R S ( 2 ) A = 4 T O T A L C O N D U C T O R S A , ( 2 ) B = 6 T O T A L C O N D U C T O R S T R A N A D D E D S P E A K E R / S T R O B E - C E I L I N G 2 S S A D D E D S P E A K E R O N L Y - C E I L I N G 3 S C C C S S S P E A K E R / S T R O B E - C E I L I N G 4 C ( E ) ( E ) S S C S S C S S C S S C S C S C 1 S , L S P 1 - 6 1 / 2 W S P 1 - 5 1 / 2 W L 1 - 4 1 5 c d S P 1 - 4 1 / 2 W L 1 - 3 1 5 c d S P 1 - 1 1 / 2 W L 1 - 1 7 5 c d S P 1 - 2 1 / 2 W L 1 - 2 7 5 c d S P 1 - 3 1 / 2 W ( 4 T W I S T S P E R F O O T ) S C S P 1 - 7 1 / 2 W E X I S T I N G D E V I C E ( E ) X Y Z Z Y * H A T C H D E N O T E S A R E A O U T O F S C O P E ( E ) 1 S , L A D D E D T O M E E T C O D E ( 2 / 1 4 / 2 0 2 3 ) R E V I S I O N N O T E S : Z A D D E D T O M E E T S I T E R E Q U I R E M E N T ( 2 / 1 4 / 2 0 2 3 ) Y A D D E D T O M E E T I N T E L L I G I B I L I T Y ( 2 / 1 4 / 2 0 2 3 ) X All electrical work to comply with 2017 NEC