Loading...
HomeMy WebLinkAboutREDLINED UPDATED PLANS - 21-00814 - 2943 W 3800 S - Strong Shed with Living SpaceAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : RP04STB0010060 - Strong Shed with Living Space Address : RP04STB0010060 Application Type : Document Filename : STRONG SHED PLANS - 21-00814 - RP04STB0010060 - Strong Shed with Living Space.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments T1.1 Free text Cody Jones : Building Open 1 Ground snow load 50 Roof snow load 35 T1.1 Free text Cody Jones : Building Open 1 If located in flood zone, we will need flood certificate. T1.1 Free text Cody Jones : Building Open 1 Risk category? A1.1 Free text Cody Jones : Building Open 2 2% max cross slope. A1.1 Free text Cody Jones : Building Open 2 As per table 602, Fire resistance rating on exterior walls is 1 hour due to separation distance. A2.1 Free text Cody Jones : Building Open 3 Penetrations shall comply with IBC Section 714 for rated assemblies. A2.1 Comment Cody Jones : Building Open 3 Concealed spaces are fireblocked/draftstopped per Section 718 A2.1 Free text Cody Jones : Building Open 3 Guards to comply with Section 1015. A2.1 Free text Cody Jones : Building Open 3 Handrails to comply with section 1014. A2.2 Free text Cody Jones : Building Open 4 Safety glazing required any window within a 2' arch of the edge of door. Glass and glazing shall comply with chapter 24. # 21-00814 Madison County - Commercial Report Date: 10.20.2021 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A2.2 Free text Cody Jones : Building Open 4 Roof and roof fire classification B? A2.2 Free text Cody Jones : Building Open 4 Where fire wall intersects exterior wall one of the following conditions in Section 706.5.1 shall apply. A6.1 Free text Cody Jones : Building Open 6 7" max riser. Stairways to comply with sections 1011 and 1019. A8.1 Free text Cody Jones : Building Open 7 36" A8.1 Free text Cody Jones : Building Open 7 Damp proofing/water proofing to comply with section 1805. E1.1 Free text Cody Jones : Building Open 17 Exit lighting and exit signs shall comply with IBC section 1008 and 1013. A1.1 Callout Stan Crittenden : Fire Open 2 Is this intended for fire department access to the back of the property? If so min. width needs to be 20' drivable surface. Report Date: 10.20.2021 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org)