Loading...
HomeMy WebLinkAboutREDLINED PLANS - 21-00814 - 2943 W 3800 S - Strong Shed with Living SpaceAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : RP04STB0010060 - Strong Shed with Living Space Address : RP04STB0010060 Application Type : Document Filename : STRONG SHED PLANS - 21-00814 - RP04STB0010060 - Strong Shed with Living Space.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments T1.1 Free text Cody Jones : Building Open 1 Ground snow load 50 Roof snow load 35 T1.1 Free text Cody Jones : Building Open 1 If located in flood zone, we will need flood certificate. T1.1 Free text Cody Jones : Building Open 1 Risk category? A1.1 Free text Cody Jones : Building Open 2 2% max cross slope. A1.1 Free text Cody Jones : Building Open 2 As per table 602, Fire resistance rating on exterior walls is 1 hour due to separation distance. A2.1 Free text Cody Jones : Building Open 3 Penetrations shall comply with IBC Section 714 for rated assemblies. A2.1 Comment Cody Jones : Building Open 3 Concealed spaces are fireblocked/draftstopped per Section 718 A2.1 Free text Cody Jones : Building Open 3 Guards to comply with Section 1015. A2.1 Free text Cody Jones : Building Open 3 Handrails to comply with section 1014. A2.2 Free text Cody Jones : Building Open 4 Safety glazing required any window within a 2' arch of the edge of door. Glass and glazing shall comply with chapter 24. # 21-00814 Madison County - Commercial Report Date: 10.20.2021 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A2.2 Free text Cody Jones : Building Open 4 Roof and roof fire classification B? A2.2 Free text Cody Jones : Building Open 4 Where fire wall intersects exterior wall one of the following conditions in Section 706.5.1 shall apply. A6.1 Free text Cody Jones : Building Open 6 7" max riser. Stairways to comply with sections 1011 and 1019. A8.1 Free text Cody Jones : Building Open 7 36" A8.1 Free text Cody Jones : Building Open 7 Damp proofing/water proofing to comply with section 1805. E1.1 Free text Cody Jones : Building Open 17 Exit lighting and exit signs shall comply with IBC section 1008 and 1013. A1.1 Callout Stan Crittenden : Fire Open 2 Is this intended for fire department access to the back of the property? If so min. width needs to be 20' drivable surface. Report Date: 10.20.2021 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) Ground snow load 50 Roof snow load 35 If located in flood zone, we will need flood certificate. Risk category? 2% max cross slope. 8 . 0 0 f t 9 . 0 1 f t As per table 602, Fire resistance rating on exterior walls is 1 hour due to separation distance. Is this intended for fire department access to the back of the property? If so min. width needs to be 20' drivable surface. Penetrations shall comply with IBC Section 714 for rated assemblies. Guards to comply with Section 1015. Handrails to comply with section 1014. 1 . 5 8 f t Safety glazing required any window within a 2' arch of the edge of door. Glass and glazing shall comply with chapter 24. Roof and roof fire classification B? Where fire wall intersects exterior wall one of the following conditions in Section 706.5.1 shall apply. 7" max riser. Stairways to comply with sections 1011 and 1019. 36" Damp proofing/water proofing to comply with section 1805. Exit lighting and exit signs shall comply with IBC section 1008 and 1013.