HomeMy WebLinkAboutFOUNDATION MEMORANDUM - 21-00814 - 2943 W 3800 S - Strong Shed with Living Space
South Fork Design
Rexburg, ID
Braydan Newton
Strong Shed
Re: Foundation
Dear Mr. Brayden Newton:
Per request, we may use the following in place of the concrete changes for the slab and footings along
the waiting room/break room and porch exterior:
Concrete
Concrete Slab:
o Shall be 5” thickness with synthetic fiber mesh.
Concrete Footings:
o The waiting room on the first floor bearing walls that are currently F7’s (30”x10” Cont.
Footers with (3) #4 bar cont.) can be F5’s (20x”x10” Cont. Footers with (2) #4 bar cont.)
Concrete Porch:
o In place of the continuous footer along the porch, we can replace that and use a 24”
Bigfoot footing with an 8” Pier with (2) #4 bars.
If you have any questions, please contact me at 208-852-6236.
Respectfully,
Ray McDougal, P.E. Reviewed By: JJC
SOUTH FORK DESIGN