Loading...
HomeMy WebLinkAboutPLANS - 23-00136 - 175 W 2nd S - AT&T ModificationREVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG TITLE SHEET DRIVING DIRECTIONS VICINITY MAP DO NOT SCALE DRAWINGS SITE PHOTO CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. SITE INFORMATION APPLICABLE CODES BUILDING CODE 2018 IBC ELECTRICAL CODE 2017 NEC TIA-222-H CONTACT INFORMATION SCOPE OF WORK T-1 T-1 TITLE SHEET 1 C-1 C-2 EQUIPMENT PLAN GN-1 GENERAL NOTES DRAWING INDEX SHEET NO.DESCRIPTION REVTOWER OWNER:HEMMING CEDARS II LLC SITE NUMBER-NAME: IDL04029-BYU_IDAHO_2 SITE ADDRESS:175 WEST 2ND SOUTH REXBURG, ID 83440 COUNTY:MADISON LATITUDE: 43.821639 (43° 49' 17.90" N) LONGITUDE:-111.788375 (111° 47' 18.15" W) GROUND ELEVATION: 4930.1' AMSL OCCUPANCY TYPE: UNMANNED ZONING JURISDICTION: CITY OF REXBURG PARCEL NUMBER:RPR4SE0008001C POWER PROVIDER: ROCKY MOUNTAIN POWER TELCO PROVIDER:CABLE ONE INC. STARTING FROM REXBURG MADISON COUNTY AIRPORT, 296 AIRPORT RD, REXBURG ID 83440: HEAD SOUTH ON AIRPORT RD TOWARD WINGIT WAY, TURN LEFT ONTO ID-33 E, TURN RIGHT ONT S 2ND W, PASS BY JIMMY JOHN'S (ON THE LEFT), TURN LEFT ONT W 2NE S. 72'-0" ROOFTOP 5G NR 1SR CBand, CBand_DoD at&t IDL04029 BYU_IDAHO_2 FA#: 10552300 PTN#: 3771A152AT/3771A153ZT PACE ID: MRUTH053768/MRUTH053874 C-3 TOWER ELEVATIONS C-4 ANTENNA PLANS C-5 RF WARNING & EQUIPMENT DETAILS SITE PLAN 1 1 1 1 1 1 E-1 ELECTRICAL DIAGRAM 1 RFDS VERSION : DATE UPDATED:3.00 G-1 GROUNDING DETAILS 1 2/28/2023 EQUIPMENT LEVEL ANTENNA LEVEL ·INSTALL PROPOSED (1) AMIA, (3) ABIO & (1) ASIL TO LTE RACK ·INSTALL (3) PROPOSED 5G CBAND ANTENNAS ·INSTALL (3) PROPOSED 5G DOD ANTENNAS ·EXISTING MAST PIPES TO BE REPLACED WITH 3" STD. x 16'-0" LONG (TYP. 3) (SECTOR BETA ONLY) ·EXISTING CORNER PLATE TO BE REPLACED WITH NEW 20"x6"x3/4" & W/(8) NEW BOLTS SAME AS EXISTING (TYP. 3) ·EXISTING BOTTOM FRAME RAIL TO BE REPLACED WITH L3x3x10'-6" LONG (TYP. 6) ·EXISTING CORNER ANGLE TO BE REPLACE WITH L3 1 2 x3x3/8x1'-6" LONG (TYP. 6) ·(27) 8x8x16 HOLLOW CMU BALLAST BLOCKS TO BE ADDED NOT TO SCALE SITE A&E SERVICES: TRILEAF CORPORATION 1821 WALDEN OFFICE SQUARE SUITE 500 SCHAUMBURG, IL 60173 CONTACT: HILDA ALLAWIRDI PHONE: (630) 227-0202, EXT. 537 EMAIL: h.allawirdi@trileaf.com SITE ACQUISITION SERVICES: SMARTLINK GROUP, LLC 1997 ANNAPOLIS EXCH. PWKY SUITE 200 ANNAPOLIS, MD 21401 CONTACT: TAMARA SHIVELEY PHONE: (801) 230-4877 S-1 & S-2 MODIFICATION DESIGN 1 C-3A TOWER ELEVATIONS 1 REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG GENERAL NOTES GN-1 GENERAL CONSTRUCTION NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: GENERAL CONTRACTOR: TBD SUBCONTRACTOR: TBD 2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND AT&T PROJECT SPECIFICATIONS. 3. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL CONTRACTOR AND SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF WORK. 5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 6. UNLESS OTHER WISE, THE WORK SHALL INCLUDE FURNISHING, MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 7. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO BE FINISH SURFACES UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF WORK AND PREPARED BY THE ARCHITECT/ENGINEERPRIOR TO PROCEEDING WITH WORK. 8. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE SPACE FOR APPROVAL BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING. 10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA, ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS AND LOCAL JURISDICTION. 11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH OTHER DISCIPLES. 12. ERECTION SHALL BE DONE IN A WORK MANLIKE MANNER BY COMPETENT EXPERIENCED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED BY LOCAL JURISDICTION. SUB CONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS. 14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES. SUB CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS THAT DEVIATE FROM THE DRAWING PRIOR TO THE BEGINNING CONSTRUCTION. 15. SUBCONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS PRIOR TO THE COMMENCEMENT OF WORK. 16. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTORS EXPENSE TO THE SATISFACTION OF THE OWNER. 17. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND SUBCONTRACTORS TO THE SITE AND/OR BUILDING. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION. 20. THE GENERAL CONTRACTOR SHALL MAINTAIN GOOD CONDITION ONE COMPLETE SET OF PLANS WITH ALL REVISION, ADDENDA, AND CHANGES ORDERS ON THE PREMISES AT ALL TIMES. 21. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION, EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT CONTROL. 22. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH GRADE AND COMPACTED TO 95 PERCENT STANCE PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80 PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE, ALL TRENCHES IN PUBLIC RIGHT OF WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL, PRE-APPROVED BY THE LOCAL JURISDICTION. 23. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER. ELECTRICAL GROUNDING SPECIFICATIONS: 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE CURRENTLY IN EFFECT FOR THE AUTHORITY HAVING JURISDICTION. 2. ALL GROUNDING DEVICE SHALL BE U.L. LISTED FOR THEIR INTENDED USE. 3. GROUND WIRES SHALL BE TINNED #2 AWG BARE SOLID COPPER UNLESS OTHERWISE NOTED. 4. CONNECTIONS OF ALL GROUND WIRES TO THE GROUND RING SHALL BE EXOTHERMIC (CAD-WELDED), UNLESS OTHERWISE NOTED AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND AT&T WIRELESS BROADBAND STANDARDS. 5. GROUNDING CONDUCTORS SHALL BE ROUTED ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE WHEN REQUIRED. GROUND LEADS SHALL BE BENT TO A MINIMUM OF 8' RADIUS. 6. WHERE GROUND WIRES ARE ROUTED FROM ANY CONNECTION ABOVE GRADE TO THE GROUND RING, INSTALL WIRE IN 314' HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM CONNECTION POINT TO 5' BELOW GRADE AND SEAL THE TOP WITH SILICONE SEALANT. 7. ALL GROUND BARS SHALL BE TINNED COPPER, SECTOR BARS 2", COLLECTOR AND MGB BARS 4", OF SUFFICIENT LENGTH TO ACCOMMODATE ALL REQUIRED CONNECTIONS WITHOUT DOUBLING LIGS, AND EACH INSTALLED WITH ISOLATORS. WHEN CONNECTING GROUND BARS (WITHIN 10 FEET OF GRADE) DIRECTLY TO THE GROUND RING, 2 EA. #2 SOLID DOWNLEADS SHALL BE CAD-WELDED TO THE GROUNDING, 1 AT EACH OPPOSITE BOTTOM CORNER, AND EACH SHALL RUN IN 3/4" HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM GROUND BAR DOWN TO THE GROUND RING, WHEN CONNECTING SECTOR GROUND BARS, DAISY-CHAIN THE GROUND BARS AND RUN 1 EA. #2 AWG STRANDED COPPER WIRE WITH THWN INSULATION FROM THE MIDDLE GROUND BAR TO THE GROUND RING AND CAD-WELD TO THE RING. 8. WHEN ATTACHING STRANDED GROUND LEADS TO THE GROUND BARS, 2 HOLE COMPRESSION LUGS SHALL BE USED, PROTECT WITH WEATHERPROOF HEAT SHRINK, AND WITH A THIN COAT OF "KOP'R SHIELD' OR EQUIVALENT PROPERLY APPLIED AND ATTACHED ONLY WITH STAINLESS STEEL HARDWARE. 9. WHEN GROUNDING EQUIPMENT ENCLOSURES, PANELS, FRAMES, AND OTHER METAL APPARATUS, A #6 AV/G STRANDED COPPER WIRE WITH THWN INSULATlON SHALL BE ATTACHED UTILIZING A 2 HOLE COMPRESSION TYPE LUG, PROTECTED WITH WEATHERPROOF HEAT A CLEAN AND CORROSION FREE METALLIC SURFACE UTILIZING STAINLESS STEEL SELF-TAPPING SCREWS AS NOTED IN NOTE 10 BELOW. 10. PREPARE ALL BONDING SURFACES FOR GROUND CONNECTIONS BY REMOVING ANY AND ALL PAINT AND CORROSION TO SHINY METAL. CAD-WELDED CONNECTIONS TO NON-GOPPER SURFACES, APPLY ONE COAT OF ANY ANTI-OXIDIZING PAINT, "COLD GALV" OR EQUIVALENT. 11. GROUND RODS SHALL BE COPPER-CLAD STEEL 5/8"x10', SPACED NO LESS THAN 10' ON CENTER. 12. ALL GROUND SYSTEM CONDUCTORS AND CONDUITS SHALL BE SECURED UTILIZING ONLY NONMETALLIC, NON-CONDUCTIVE, UV RATED CLAMPS, BRACKET, AND OR SUPPORTS. 13. WHEN REQUIRED, THE CONTRACTOR SHALL ENGAGE THE SERVICES OF AN INDEPENDENT TESTING FIRM TO VERIFY, UTILIZING A MEGGER TEST, THAT THE RESISTANCE TO EARTH OF THE NEW GROUND SYSTEM IS EQUAL TO OR LESS THAN 5 (OHMS). A COPY OF THE COMPLETE TESTING REPORT SHALL BE PROVIDED TO THE AT&T REPRESENTATIVE. 14. ALL MATERIALS AND HARDWARE SHALL BE INSTALLED IN A WORKMAN-LIKE MANNER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, AND DEFINED IN NFPA-70. 15. ALL RRH GROUND WIRES SHALL BE #2 GREEN STRANDED. 16. ALL GROUND LUGS SHALL BE 2-HOLE LONG BARRELL. 17. OUTDOOR GROUNDS SHALL BE BLACK HEAT SHRINK W/O INSPECTION HOLES. 18. INDOOR GROUNDS SHALL BE CLEAR HEAT SHRINK W/ INSPECTION HOLES. ANTENNA PIPE MOUNTS: 1. PROPOSED OR REPLACEMENT ANTENNA PIPE MOUNTS SHALL BE 2-3/8" (O.D.)X10', SCH. 80 PIPE, UNLESS NOTED OTHERWISE. REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG SITE PLAN SITE PLAN 1 C-10SCALE: 1" = 30' (24x36) (OR) 1" = 60' (11x17) 15' 30'30' THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM THE INFORMATION AVAILABLE. THE INFORMATION PROVIDED IS NOT IMPLIED NOR INTENDED TO BE A COMPLETE INVENTORY OF THE UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. EXISTING PARKING GARAGE EXISTING AT&T EQUIPMENT ROOM AT LEVEL 5 EXISTING ROOFTOP (SEE SHEET C-3 FOR DETAILS) PROPOSED/EXISTING ANTENNAS AND RRH UNITS (SEE SHEET C-4 FOR DETAILS) NOTE: THESE DRAWINGS WERE PREPARED BASED ON EXISTING DRAWINGS AND INFORMATION PROVIDED BY OTHERS. ALL EXISTING CONDITIONS SHOULD BE FIELD VERIFIED PRIOR TO CONSTRUCTION. W 2ND S S 2 N D W S 1 S T W EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING BUILDINGEXISTING BUILDING EXISTING BUILDING EXISTING BUILDING EXISTING AT&T EQUIPMENT (SEE SHEET C-2 FOR DETAILS) 22'-8" EXISTING (6) #6 DC TRUNKS & (3) 24 PAIR FIBER TRUNKS REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG C-2 EQUIPMENT PLAN 2EXISTING EQUIPMENT PLAN 0 1'SCALE: 3/4" = 1'-0" (24x36) (OR) 3/8" = 1'-0" (11x17) 1'2' 8 5' - 6 " 13'-6" NEW EQUIPMENT PLAN KEY NOTES: EXISTING AT&T EQUIPMENT ROOM1 EXISTING POWER PLANT2 EXISTING LTE RACK3 EXISTING TELCO RACK4 5 EXISTING TELCO BOARD6 EXISTING ENTRY PORT7 8 EXISTING WALL MOUNTED AC UNIT EXISTING AC PANEL 1 2 34 5 6 7 10 9 101'SCALE: 3/4" = 1'-0" (24x36) (OR) 3/8" = 1'-0" (11x17) 1'2' 11 EXISTING FIBER STORAGE9 EXISTING CABLE TRAY10 11 EXISTING ACCESS DOOR 8 KEY NOTES: EXISTING AT&T EQUIPMENT ROOM1 EXISTING POWER PLANT2 EXISTING LTE RACK PROPOSED (1) AMIA, (3) ABIO & (1) ASIL TO BE INSTALLED3 EXISTING TELCO RACK4 5 EXISTING TELCO BOARD6 EXISTING ENTRY PORT7 8 EXISTING WALL MOUNTED AC UNIT EXISTING AC PANEL 1 2 34 5 6 7 10 9 11 EXISTING FIBER STORAGE9 EXISTING CABLE TRAY10 11 EXISTING ACCESS DOOR PROPOSED (1) AMIA, (3) ABIO, & (1) ASIL TO BE INSTALLED IN EXISTING LTE RACK 5' - 6 " 13'-6" 6'-0" 2' - 0 " REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG C-3 TOWER ELEVATIONS 2PROPOSED SOUTH EAST ELEVATION (SECTOR BETA) 104' 8'8'SCALE: 1/8" = 1'-0" (24x36) (OR) 1/16" = 1'-0" (11x17) 0 4' 8'8'SCALE: 1/8" = 1'-0" (24x36) (OR) 1/16" = 1'-0" (11x17) NOTE: STRUCTURAL ANALYSIS MUST BE PERFORMED BEFORE THE INSTALLATION OF NEW ANTENNAS, RRH UNITS, ETC. EXISTING SOUTH EAST ELEVATION (SECTOR BETA) (6) EXISTING XXQLH-654L8H8-IVT ANTENNA TO REMAIN (TYP. 2 PER SECTOR) EXISTING (3) DC9 RAYCAPS TO REMAIN (TYP. 1 PER SECTOR) (9) EXISTING RRHS TO REMAIN (TYP. 3 PER SECTOR) INSTALL (3) AEQU DOD ANTENNA IN TOP LOCATION (1 PER SECTOR) INSTALL (3) AEQK C-BAND ANTENNAS IN BOTTOM LOCATION (1 PER SECTOR) SEE C-5/3&4 FOR DETAILS EXISTING ANTENNA SECTOR FRAME EXISTING ANTENNA SECTOR FRAME (6) EXISTING XXQLH-654L8H8-IVT ANTENNA TO REMAIN (TYP. 2 PER SECTOR) EXISTING (3) DC9 RAYCAPS TO REMAIN (TYP. 1 PER SECTOR) (9) EXISTING RRHS TO REMAIN (TYP. 3 PER SECTOR) NOTE: NEW EQUIPMENT TO BE PAINTED TO MATCH REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG C-3A TOWER ELEVATIONS 2PROPOSED NORTH ELEVATION 104' 8'8'SCALE: 1/8" = 1'-0" (24x36) (OR) 1/16" = 1'-0" (11x17) 0 4' 8'8'SCALE: 1/8" = 1'-0" (24x36) (OR) 1/16" = 1'-0" (11x17) NOTE: STRUCTURAL ANALYSIS MUST BE PERFORMED BEFORE THE INSTALLATION OF NEW ANTENNAS, RRH UNITS, ETC. EXISTING NORTH ELEVATION (6) EXISTING XXQLH-654L8H8-IVT ANTENNA TO REMAIN (TYP. 2 PER SECTOR) EXISTING (3) DC9 RAYCAPS TO REMAIN (TYP. 1 PER SECTOR) (9) EXISTING RRHS TO REMAIN (TYP. 3 PER SECTOR) INSTALL (3) AEQU DOD ANTENNA IN TOP LOCATION (1 PER SECTOR) INSTALL (3) AEQK C-BAND ANTENNAS IN BOTTOM LOCATION (1 PER SECTOR) SEE C-5/3&4 FOR DETAILS EXISTING ANTENNA SECTOR FRAME (6) EXISTING XXQLH-654L8H8-IVT ANTENNA TO REMAIN (TYP. 2 PER SECTOR) EXISTING (3) DC9 RAYCAPS TO REMAIN (TYP. 1 PER SECTOR) (9) EXISTING RRHS TO REMAIN (TYP. 3 PER SECTOR) EXISTING ANTENNA SECTOR FRAME NOTE: NEW EQUIPMENT TO BE PAINTED TO MATCH REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG C-4 NOTE TO CONTRACTOR: 1. ANTENNA CLEARANCE AND MOUNTING TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION WITH FINAL ANTENNA SPECIFICATIONS MOUNTING HARDWARE AND RF DESIGN. ANTENNA PIPE MOUNT MODIFICATION MAY BE REQUIRED. 2. CONTRACTOR TO VERIFY FINAL ANTENNA CONFIGURATION FROM FINAL RFDS. 3. CONTRACTOR SHALL VERIFY A MINIMUM OF 4 FEET SEPARATION BETWEEN ALL ANTENNAS. 4. STRUCTURAL ANALYSIS MUST BE PERFORMED ON ALL ROOFTOPS, FLAGPOLES, LIGHT POLES, AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, RRH UNITS, ETC. ANTENNA PLANS 2 1 PROPOSED ANTENNA PLAN EXISTING ANTENNA PLAN SCALE: NTS SCALE: NTS EXISTING ANTENNA AND TRANSMISSION CABLE REQUIREMENT RAD ANTENNA TYPE QTY LENGTH TYPE TRANSMISSION CABLEANTENNA AZIMUTHTECHNOLOGY XXQLH-654L8H8-IVTA1 A2 GA M M A , 6 8 ' - 0 " B E T A , 6 8 ' - 0 " AL P H A , 6 8 ' - 0 " SECTOR CTR - 0° PROPOSED ANTENNA AND TRANSMISSION CABLE REQUIREMENT RAD ANTENNA TYPE QTY LENGTH TYPE TRANSMISSION CABLEANTENNA AZIMUTHTECHNOLOGY SECTOR CTR A3 AL P H A , 6 8 ' - 0 " & 6 9 ' - 0 " LTE WCS GA M M A , 6 8 ' - 0 " & 6 9 ' - 0 " B E T A , 7 6 ' - 0 " & 7 7 ' - 0 " B1 B2 C1 C2 A1 A2 B3 B1 B2 C3 C1 C2 A3 B3 C3 A4 B4 C4 A4 B4 C4 - 120° - 240° (6) EXISTING XXQLH-654L8H8-IVT ANTENNA TO REMAIN (TYP. 2 PER SECTOR) AEQK+AEQU STACKED 0°-140'FIBER EXISTING (3) DC9 RAYCAPS TO REMAIN (TYP. 1 PER SECTOR) 5G CBAND/DOD (9) EXISTING RRHS TO REMAIN (TYP. 3 PER SECTOR) EMPTY EMPTY - - LTE 700/1900/AWS - 0° - 120° - 240° B-1 LTE WCS B-2 EMPTY B-3 EMPTY B-4 LTE 700/ 1900/AWS INSTALL (3) AEQU DOD ANTENNA IN TOP LOCATION (1 PER SECTOR) INSTALL (3) AEQK C-BAND ANTENNAS IN BOTTOM LOCATION (1 PER SECTOR) SEE C-5/3&4 FOR DETAILS XXQLH-654L8H8-IVT XXQLH-654L8H8-IVT LTE WCS EMPTY EMPTY - - LTE 700/1900/AWSXXQLH-654L8H8-IVT XXQLH-654L8H8-IVT LTE WCS EMPTY EMPTY - - LTE 700/1900/AWSXXQLH-654L8H8-IVT -140'FIBER -140'FIBER --- --- -140'FIBER -140'FIBER --- --- -140'FIBER -140'FIBER --- --- XXQLH-654L8H8-IVT 0°LTE WCS/5G WCS EMPTY - LTE 700/1900/AWS/5G AWS - 0°XXQLH-654L8H8-IVT -140'FIBER -140'FIBER --- AEQK+AEQU STACKED 120°-140'FIBER5G CBAND/DOD XXQLH-654L8H8-IVT 120°LTE WCS/5G WCS EMPTY - LTE 700/1900/AWS/5G AWS - 120°XXQLH-654L8H8-IVT -140'FIBER -140'FIBER --- AEQK+AEQU STACKED 240°-140'FIBER5G CBAND/DOD XXQLH-654L8H8-IVT 240°LTE WCS/5G WCS EMPTY - LTE 700/1900/AWS/5G AWS - 240°XXQLH-654L8H8-IVT -140'FIBER -140'FIBER --- A-1 LTE WCS C-1 LTE WCS A-2 EMPTY C-2 EMPTY A-3 EMPTY C-3 EMPTY A-4 LTE 700/ 1900/AWS C-4 LTE 700/ 1900/AWS B-1 LTE WCS/ 5G WCS B-2 EMPTY B-3 5G CBAND/ DOD B-4 LTE 700/ 1900/AWS/ 5G AWS A-1 LTE WCS/ 5G WCS C-1 LTE WCS/ 5G WCS A-2 EMPTY C-2 EMPTY A-3 5G CBAND/ DOD C-3 5G CBAND/ DOD A-4 LTE 700/ 1900/AWS/ 5G AWS C-4 LTE 700/ 1900/AWS/ 5G AWS (6) EXISTING XXQLH-654L8H8-IVT ANTENNA TO REMAIN (TYP. 2 PER SECTOR) EXISTING (3) DC9 RAYCAPS TO REMAIN (TYP. 1 PER SECTOR) (9) EXISTING RRHS TO REMAIN (TYP. 3 PER SECTOR) EXISTING ANTENNA SECTOR FRAME EXISTING ANTENNA SECTOR FRAME EXISTING CORNER ANGLE TO BE REPLACE WITH L3 1/2x 3x 1'-6" LONG (TYP. 6) SEE SHEET S-2 FOR MODIFICATION DESIGN EXISTING MAST PIPE TO BE REPLACED WITH 3" STD. x 16'-0" LONG (BETA SECTOR ONLY (TYP. 3) SEE SHEET S-2 FOR DETAILS EXISTING BOTTOM FRAME RAIL TO BE REPLACE WITH L3 x 3x 10'-6" LONG (TYP. 6) SEE SHEET S-2 FOR MODIFICATION DESIGN (27) 8x8x16 HOLLOW CMU BALLAST BLOCKS TO BE ADDED SEE SHEET S-2 FOR DETAILS EXISTING CORNER PLATE TO BE REPLACE WITH NEW 20" x 6"x 3/4" & W/ (8) NEW BOLTS SAME AS EXISTING (TYP. 3) SEE SHEET S-2 FOR MODIFICATION DESIGN REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG C-5 RF WARNING & EQUIPMENT DETAILS 1RF WARNING SIGNAGE RRH MOUNTING DETAILS 3 CAUTION AT&T Mobility WARNING Beyond this point: Radio frequency fields at this site exceed FCC rules for human exposure. Failure to obey posted signs and site guidelines for working in radio frequency AT&T MobilityRef: FCC 47 CFR 1.1307(b) environments could result in serious injury. Radio frequency fields beyond this point may exceed FCC general public exposure limit. Obey all posted signs and site guidelines for working in radio frequency AT&T Mobility environments. NOTICE Ref: FCC 47 CFR 1.1307(b) Beyond this point: Radio frequency fields at this site exceed FCC rules for human exposure. Four your safety, obey all posted signs and site guidelines for working in radio frequency environments. Ref: FCC 47 CFR 1.1307(b) SCALE: NTS SCALE: NTSANTENNA INFORMATION 4SCALE: NTS 2SCALE: NTSC-BAND ANTENNA STACKED DETAIL MANUFACTURER NOKIA MODEL #AEQK DIMENSIONS (HxWxD) 29.53" x 17.72" x 9.45" NET WEIGHT <99 lbs (WITHOUT MOUNTING BRACKETS) OPTICAL PORTS 2 x SFP28, 10/25GE eCPRI FREQUENCY 3700-3980MHz MANUFACTURER NOKIA MODEL #AEQU DIMENSIONS (HxWxD) 29.53" x 17.72" x 9.45" NET WEIGHT <99 lbs (WITHOUT MOUNTING BRACKETS) OPTICAL PORTS 2 x SFP28, 10/25GE eCPRI FREQUENCY 3450-3550 MHz 1' - 0 " 2' - 6 " 2' - 6 " NEW 2-3/8" (O.D.), SCH. 40 PIPE MOUNT AEQK ANTENNA SEE DETAIL 1 FOR ANTENNA DETAILS AEQU ANTENNA SEE DETAIL 2 FOR ANTENNA DETAILS TOP FRONT BOTTOM SIDEBACK 17.72" 29 . 5 3 " 9.45" TOP FRONT BOTTOM SIDEBACK 17.72" 29 . 5 3 " 9.45" REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG E-1 ELECTRICAL DIAGRAM 1SCALE: NTSDC POWER & FIBER SINGLE LINE DIAGRAM EXISTING POWER PLANT RACK TO SOURCE TO SOURCE EXISTING 200A POWER PROTECTION PANELEXISTING 200A, 120/240V, 1 PHASE METER EXISITING CONDUIT 200A 1" EMT EXISTING CONDUIT CONDUCTOR NOTES: 1. ALL CONDUCTOR SHALL BE COPPER. 2. ALL WIRING SHALL BE COPPER WITH THHN/THWN DUAL RATED 600 VOLTS INSULATION. 3. CONDUCTORS SHALL BE 12 AWG MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE. 4. GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER UNLESS OTHERWISE NOTED. REVISIONS REV DATE DESCRIPTION 0 08/23/22 ISSUED FOR REVIEW 90% SITE #: IDL04029 SITE NAME: BYU_IDAHO_2 FA #: 10552300 175 WEST 2ND SOUTH REXBURG, ID 83440 INT JG Smartlink LLC 1997 Annapolis Exch.Pkwy # 200 Annapolis, MD 21401 Tel: 410-263-LINK (5465) Fax: 410-263-5470 www.smartlinkllc.com 706310 0 09/30/22 ISSUED FOR REVIEW 95%JG 0 01/24/23 ISSUED FOR REVIEW 98%JG 0 03/06/23 ISSUED FOR REVIEW 100% JG 1 03/22/23 ISSUED FOR FINAL JG G-1 TYPE VV TYPE GT TYPE TA TYPE GY TYPE GR TYPE VN TYPE NC TYPE VS TYPE VB TYPE SS TYPE PT NOTE: ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH PROJECT MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. TYPE 2-YA-2 TYPE XA TYPE YA-2TYPE HS 0. 0 0 0 " 0. 5 0 0 " 1. 5 0 0 " 2. 5 0 0 " 3. 5 0 0 " 4. 5 0 0 " 5. 5 0 0 " 6. 5 0 0 " 7. 5 0 0 " 8. 5 0 0 " 9. 5 0 0 " 10 . 5 0 0 " 10 . 5 0 0 " 10 . 5 0 0 " 0.500" 1.250" 2.000" 2.875" 3.500" 1.125" 0.000" 4.000" 56.20 (4) 437.00 (26) NO. 4150A414 INSULATION NO. WBKT1 WALL BRACKET 1.50"1.00" NOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND FROM ANTENNA JUMPER (TYP) APPROVED GROUNDING KIT (TYP) ANTENNA CABLE TRAY TO CABLE TRAY (TYP) FROM ANTENNA FRAME SUPPORT #2 AWG BCW BONDED TO GROUND WIRE ALONG CABLE TRAY #6 AWG #2 AWG BCW GROUNDING BAR MOUNTED NEAR ANTENNAS GROUNDING DETAILS APPROVED WEATHER PROOFING KIT (TYP) TYPICAL GROUNDING SCHEMATIC 4 1 5 2 7 6 3 EXOTHERMIC WELDING 12" & 18" GROUND BARS NOT USED COAX GROUNDING DETAIL NOT USED MECHANICAL LUG CONNECTION EXISTING GROUND LEVEL EXISTING GPS SURGE PROTECTION EXISTING #6 AWG STRANDED COPPER CONDUCTOR WITH GREEN, 600V, THWN-2 INSULATION, GROUNDED TO GROUND BAR WITH 2-HOLE COMPRESSION LUG EXISTING FIBER CABLE TRAY EXISTING RAYCAP DC6-48-60-RM SURGE PROTECTION EXISTING 2"X20" DC BUS BAR BONDED TO "P" SECTION OF THE CELL REFERENCES GROUND BAR (CRGB) WITH #2 AWG WIRE AND 2-HOLE COMPRESSION LUG Raycap EXISTING LTE BBU EXISTING eAM ALARM MODULE Raycap Raycap Raycap Raycap NOTES: 1. ALL HARDWARE BOLT, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER, GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. 2. COPPER SHIELD, ANTIOX, CR NO-OX OR EQUIVALENT SHALL BE PLACED WHERE ALL DISSIMILAR METALS CONNECT. 3. ALL LUGS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4. ALL RRH GROUND WIRES SHALL BE #2 GREEN STRANDED. 5. ALL GROUND LUGS SHALL BE 2-HOLE, LONG BARREL. 6. OUTDOOR GROUND LUGS SHALL BE BLACK HEAT SHRINK W/O INSPECTION HOLES. 7. INDOOR GROUND LUGS SHALL BE CLEAR HEAT SHRINK W/ INSPECTION HOLES. WIRE SIZE BURNDY LUG BOLT SIZE #2 AWG SOLID TINNED #2/0 AWG STRANDED #4/0 AWG STRANDED #2 AWG STRANDED YA3C-2TC38 YA2C-2TC38 YA26-2TC38 YA28-2N 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT 3/8"-16 NC S 2 BOLT BURNDY TWO HOLE LUG W/ LONG BARREL FOR #2 AWG STRANDED OR EQUIVALENT BARE WIRE TO BE NO-0X AT BOTH ENDS #2 AWG STRANDED GREEN INSULATION HEAT SHRINK (CLEAR) BURNDY GROUND LUG (SEE TABLE FOR SIZE AND MODEL) NUT (TYP) LOCK WASHER (TYP) GROUND BAR BOLT (TYP) GROUNDING CONDUCTOR SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS #2 AWG GREEN STRANDED GROUND FROM RRH TO SECTOR GROUND BAR (TYP) EXISTING SECTOR GROUND BAR (TYP) EXISTING #2 AWG GROUND LEADS (GC TO FIELD VERIFY) EXISTING GROUND BAR AT BASE OF TOWER EXISTING #2 AWG GROUND LEADS (GC TO FIELD VERIFY) #2 AWG GREEN STRANDED GROUND FROM DC9 TO SECTOR GROUND BAR EXISTING RRH UNIT EXISTING RAYCAP EXISTING LTE ANTENNA INTEGRATED WITHIN: AIRSCALE MAA 64T64R 192AE N77 200W AEQK, AEQU PROPOSED AEQK+AEQU STACKED ANTENNAS EXISTING RRH UNIT TOWER EXISTING LTE ANTENNA SHEET NUMBER: SHEET NAME: SITE INFORMATION: DATEREV DESCRIPTION DRAWN BY CHECKED BY PROJECT NUMBER: AL B U L E N G I N E E R I N G . A l l r i g h t s r e s e r v e d . R e p r o d u c t i o n i n w h o l e o r i n p a r t i s p r o h i b i t e d w i t h o u t t h e w r i t t e n c o n s e n t o f t h e c o p y r i g h t o w n e r . SHEET SIZE - 22"x34" AS SHOWN SCALE: CONTRACTOR: CLIENT: CARRIER: 9/30/22A ISSUED FOR REVIEW MSK AVM DMITRIY ALBUL IDAHO LICENSE NO. 15190 1515 DES PERES ROAD, STE 200 SAINT LOUIS, MISSOURI 63131 PHONE|314-997-6111 FAX|314-997-8066 SPECIAL INSPECTIONS NOTES: 1. A QUALIFIED INDEPENDENT TESTING LABORATORY, EMPLOYED BY THE OWNER AND APPROVED BY THE JURISDICTION, SHALL PERFORM INSPECTION AND TESTING IN ACCORDANCE WITH THE THE GOVERNING BUILDING CODE, APPLICABLE SECTION(S) AS REQUIRED BY PROJECT SPECIFICATIONS FOR THE FOLLOWING CONSTRUCTION WORK: a. STRUCTURAL WELDING (CONTINUOUS INSPECTION OF FIELD WELDS ONLY). b. HIGH STRENGTH BOLTS (PERIODIC INSPECTION OF A325 AND/OR A490 BOLTS) TO BE TIGHTENED PER "TURN-OF-THE-NUT" METHOD. c. MECHANICAL AND EPOXIED ANCHORAGES. d. FIBER REINFORCED POLYMER. ·THE SPECIAL INSPECTOR MUST VERIFY THAT THE FRP MATERIAL SPECIFIED ON THE APPROVED DESIGN DOCUMENTS IS BEING INSTALLED. ·THE SPECIAL INSPECTOR MUST VERIFY THAT ALL CUT EDGES AND DRILLED HOLES ARE PROPERLY SEALED USING A VINYL ESTER SEALING KIT SUPPLIED BY THE MANUFACTURER. ·THE SPECIAL INSPECTOR MUST VERIFY THAT THE STRUCTURE IS BUILT IN ACCORDANCE WITH THE APPROVED DESIGN DOCUMENTS. 2. THE INSPECTION AGENCY SHALL SUBMIT INSPECTION AND TEST REPORTS TO THE BUILDING DEPARTMENT, THE ENGINEER OF RECORD, AND THE OWNER UNLESS THE FABRICATOR IS APPROVED BY THE BUILDING OFFICIAL TO PERFORM WORK WITHOUT THE SPECIAL INSPECTIONS. STEEL CONSTRUCTION NOTES: 1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC MANUAL OF STEEL CONSTRUCTION 14TH EDITION, FOR THE DESIGN AND FABRICATION OF STEEL COMPONENTS. 2. ALL FIELD CUT SURFACES, FIELD DRILLED HOLES, AND GROUND SURFACES WHERE EXISTING PAINT OR GALVANIZATION REMOVAL WAS REQUIRED SHALL BE REPAIRED WITH (2) BRUSHED COATS OF ZRC GALVILITE COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURERS' RECOMMENDATIONS. 3. ALL FIELD DRILLED HOLES TO BE USED FOR FIELD BOLTING INSTALLATION SHALL BE STANDARD HOLES, AS DEFINED BY AISC, UNLESS NOTED OTHERWISE. 4. ALL EXTERIOR STEEL WORK SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A123. 5. ALL STEEL MEMBERS AND CONNECTIONS SHALL MEET THE FOLLOWING GRADES: ·ANGLES, PLATES TO BE A36. Fy=36 KSI, U.N.O. ·PIPES TO BE A53 GR. B Fy=53 KSI, U.N.O. ·BOLTS TO BE A325-X. Fu=120 KSI, U.N.O. ·U-BOLTS AND LAG SCREWS TO BE A307 GR A. Fu=60 KSI, U.N.O. 6. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES, U.N.O. 7. ALL WELDING SHALL CONFORM TO AISC AND AWS D1.1 LATEST EDITION. 8. ALL HILTI ANCHORS TO BE CARBON STEEL, U.N.O. ·MECHANICAL ANCHORS: KWIK BOLT-TZ, U.N.O. ·CMU BLOCK ANCHORS: ADHESIVE - HY120, U.N.O. ·CONCRETE ANCHORS: ADHESIVE - HY150, U.N.O. ·CONCRETE REBAR: ADHESIVE - RE500, U.N.O. 9. ALL STUDS TO BE NELSON CAPACITOR DISCHARGE 1/4"-20 LOW CARBON STEEL COPPER-FLASH AT 55 KSI ULT/50 KSI YIELD, U.N.O. 10. BOLTS SHALL BE TIGHTENED TO A "SNUG TIGHT" CONDITION AS DEFINED BY AISC. 11. MINIMUM EDGE DISTANCES SHALL CONFORM TO AISC TABLE J3.4. GENERAL NOTES: 1. THESE DOCUMENTS WERE DESIGNED IN ACCORDANCE WITH THE LATEST VERSION OF APPLICABLE LOCAL/STATE/COUNTY/CITY BUILDING CODES, AS WELL AS ANSI/TIA-222 STANDARD, AWWA-D100 STANDARD, NDS, NEC, MSJC, AND/OR THE LATEST VERSION OF THE INTERNATIONAL BUILDING CODE, UNLESS NOTED OTHERWISE IN THE CORRESPONDING STRUCTURAL REPORT. 2. ALL CONSTRUCTION METHODS SHOULD FOLLOW STANDARDS OF GOOD CONSTRUCTION PRACTICE. 3. ALL WORK INDICATED ON THESE DRAWINGS SHALL BE PERFORMED BY QUALIFIED CONTRACTORS EXPERIENCED IN SIMILAR CONSTRUCTION. 4. ALL NEW WORK SHALL ACCOMMODATE EXISTING CONDITIONS. IF OBSTRUCTIONS ARE FOUND, CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD PRIOR TO CONTINUING WORK. 5. ANY CHANGES OR ADDITIONS MUST CONFORM TO THE REQUIREMENTS OF THESE NOTES AND SPECIFICATIONS, AND SHOULD BE SIMILAR TO THOSE SHOWN. ALL CHANGES OR ADDITIONS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO FABRICATION AND/OR CONSTRUCTION. 6. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALL MISCELLANEOUS SHORING, BRACING, TEMPORARY SUPPORTS, ETC. NECESSARY TO PROVIDE A COMPLETE AND STABLE STRUCTURE DURING CONSTRUCTION. TIA-1019-A-2011 IS AN APPROPRIATE REFERENCE FOR THOSE DESIGNS MEETING TIA STANDARDS. THE ENGINEER OF RECORD MAY PROVIDE FORMAL RIGGING PLANS AT THE REQUEST AND EXPENSE OF THE CONTRACTOR. 7. INSTALLATION SHALL NOT INTERFERE NOR DENY ADEQUATE ACCESS TO OR FROM ANY EXISTING OR PROPOSED OPERATIONAL AND SAFETY EQUIPMENT. 8. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO ANY FABRICATION. CONTACT TRILEAF IF ANY DISCREPANCIES EXIST. S-1 706310 BYU IDAHO 2 IDL04029 175 WEST 2ND SOUTH REXBURG, ID 83440 MADISON COUNTY GENERAL NOTES 1/13/230 ISSUED FOR REVIEW MSK UVK 01-23-23 SHEET NUMBER: SHEET NAME: SITE INFORMATION: DATEREV DESCRIPTION DRAWN BY CHECKED BY PROJECT NUMBER: AL B U L E N G I N E E R I N G . A l l r i g h t s r e s e r v e d . R e p r o d u c t i o n i n w h o l e o r i n p a r t i s p r o h i b i t e d w i t h o u t t h e w r i t t e n c o n s e n t o f t h e c o p y r i g h t o w n e r . SHEET SIZE - 22"x34" AS SHOWN SCALE: CONTRACTOR: CLIENT: CARRIER: 9/30/22A ISSUED FOR REVIEW MSK AVM 706310 BYU IDAHO 2 IDL04029 175 WEST 2ND SOUTH REXBURG, ID 83440 MADISON COUNTY MODIFICATION DESIGN DMITRIY ALBUL IDAHO LICENSE NO. 15190 1515 DES PERES ROAD, STE 200 SAINT LOUIS, MISSOURI 63131 PHONE|314-997-6111 FAX|314-997-8066 S-2 SCALE 3/4"=1' FOR 11"x17" 1 1/2"=1' FOR 22"x34" 3D VIEW1 EXISTING CORNER ANGLE TO BE REPLACED WITH L3 1/2x3x3/8 x 1'-6" LONG (TYP. 6) EXISTING BOTTOM FRAME RAIL TO BE REPLACED WITH L3x3x7/16 x 10'-6" LONG (TYP. 6) EXISTING NON-PENETRATING BALLAST FRAME EXISTING 8x8x16 HOLLOW CMU BALLAST BLOCKS TO REMAIN (TYP. 12 PER TRAY, 36 TOTAL) EXISTING CORNER PLATE TO BE REPLACED WITH NEW 20"x6"x3/4" & W/ (8) NEW BOLTS SAME AS EXISTING (TYP. 3) 2 S-2 SCALE 3/16"=1' FOR 11"x17" 3/8"=1' FOR 22"x34" POST TO TRAY CONNECTION DETAIL2 EXISTING MAST PIPE SECTOR BALLAST WEIGHT, LBS ALPHA, BETA & GAMMA 2268 TOTAL, PCS 63 REQUIRED BALLAST PER PLATFORM SCALE 3/4"=1' FOR 11"x17" 1 1/2"=1' FOR 22"x34" ELEVATION VIEW3 3' - 0 " 2' - 0 " (V . I . F . ) TOP OF ROOF EXISTING NON-PENETRATING BALLAST PLATFORM (27) 8х8х16 HOLLOW CMU BALLAST BLOCKS EXISTING BASE PLATE EXISTING BALLAST TRAY EXISTING BOTTOM FRAME RAIL TO BE REPLACED WITH L3x3x7/16 x 10'-6" LONG (TYP. 6) EXISTING MAST PIPE TO BE REPLACED WITH 3" STD. x 16'-0" LONG (BETA SECTOR ONLY) (TYP. 3) 12 ' - 6 " EXISTING MAST PIPE TO BE REPLACED WITH 3" STD. x 16'-0" LONG (BETA SECTOR ONLY) (TYP. 3) 1/23/230 ISSUED FOR REVIEW MSK UVK EXISTING MOUNT PIPE (TYP. 9) (TO REMAIN)