HomeMy WebLinkAboutREVISED FS PLAN - 21-00488 - Denny's - New Commercial BldgLONGITUDINAL BRACE DETAIL LATERAL BRACE DETAIL COMPOSITE WOOD JOIST(TJI) - 1-1/2"x6"x12" WOOD BLOCKING (2) __ THOUGH BOLT �.,✓-�{{p TOLCO FIG 980. CEAN BRAGLE - " BRACE ANGLE 4CE AN 45E 59- AN TOLCO FIG 4L4L-\1"SCHAD PIPE, TO= FIG 1000 "FAST CLAMP" SPRINKLER PIPE SIDE SAMMY W/ SWIVEL ZEE PURLIN �SAMMY SIDEWINDER -TOLCO FIG ]S SW IVEL MALL THREAD ROD I SWIVELRING --M PIPE LATERAL BRACE DETAIL SOLID WOOD TOLCO FIG 906 - THOUGH BOLT (2r TOLCO FIG 980- BRACEANGLE I 45°-59° 1"SCH 40 PIPE SPRINKLER PIPE TOLCO FIG 1001 "FAST CLAMP"MP" REMOTE INSPECTORS TEST BRANCHLINE -a- V SCH.40 PIPE 1" GLOBE VALVE IH 1" UNION "GALV 45° _- w/%"ORIFICE V SCH.40 PIPE SPRINKLER PIPE WET SYSTEM AIR VENT 1/2"X0-3 NIPPLE l ,., 1/2" 90° ELBOW CLI J �'_- 12" PLUG 1/2"X0-3 NIPPLE VT BALL VALVE BRANCHLINE NOTE'. A SINGLE AIR VENT SHALL BE LOCATED NEAR A HIGH POINT IN THE SYSTEM. WOOD SIDE SAMMY SCREW WOOD JOIST - q_ SAMMY SCREW TRAPEZE HANGER DETAIL BEAM /JOIST TOP BEAM CLAMP - ALL THREAD ROD BRANCHLINE RESTRAINT (STEEL BEAM) STEEL BEAM / JOIST J 3/8" ROD �® PIPE 3CLAMPEEAM Ileryi� ALLTHREADROD BEAM CLAMP 3/8"ROD �'-TOLCO SWIVEL (FIG ]5) SWIVEL RING SWIVEL RING 291Wft 11/2"(Sch 10) SWIVEL RING 3/8"ROD PIPE - PIPE y 4.221bsft 21/2" (Sch 10) 0. REFERENCE NFPA 132019, SECTION 17.1.1 FOR SIZING BRANCHLINE PIPE UPRIGHT SPRINKLER DETAIL P�-t UPRIGHT SPRINKLER ,\ WELDEDOUTLET BRANCHLINE PIPING INSTALL SPRINKLER V-12" BELOW DECK HANGER SPACING - STEEL PIPE SIZE OF PIPE MAXHANGER WEIGHTOFWATER SUPPORTED SPACING FILLED PIPE 1" (Sch 40) 12'-0 2.051bs/H 1 1/4" (Sch 40) 12'-0 291Wft 11/2"(Sch 10) 151-0 3041Wft 2"(Sch 10) 15'-0 4.221bsft 21/2" (Sch 10) 151-0 5.891bs/ft 3" (Sch 10) 15'-0 7 941bs/ft *" (Sch 10) 15'-D 11.781Wft 6(Sch 10) 15'-0 23.03 lbs/ft UPRIGHT SPRINKLER DETAIL CEILING EIC � fIIN UPRIGHTSPRINKLER -iff J 1"SCH 40 PIPE 1"X VT ELBOW STEEL PIPE DIMENSION TABLE SCHEDULE 10 PIPE SCHEDULE 40 PIPE NOMINAL PIPE SIZE (IN.) INSIDE DIAMETER (IN) NOMINAL PIPE SIZE (IN.) INSIDE DIAMETER (IN) 1" 1.097 1" 1.049 ,'/." 1.442 1'/." 1"X 1/2" R.C. 1''A 1.682 ' TV 1.61 0 2" 2.157 2" 2.067 2%" 2 635 254' 2 489 3" 3.260 3" 3.068 4" 4.260 4" 4.026 6" 6.357 6" 6.065 8" 8.249 8" 7.981 PENDENT& UPRIGHT SPRINKLER fin =SSU SPRINKLER 1"SCHAD SPRIG- -5 1"ARMOVER 1" 90° ELBOW ---r 1"90° ELBOW h X BRANCHLINE,; ') ��T"SCHAD DROP 0 0 1"X 1/2" R.C. CEILING 1.% SEE PLAN FOR HEIGHT �SEMI-RECESSED a.+ SPRINKLER SPRINKLER AND HANGING DETAILS 'TT RISER DETAIL NO SCALE 1. 2" TO WET SYSTEM 2. HYDRAULIC INFORMATION SIGN 3.21/2" RELIABLE CR RISER W/TEST, DRAIN, AND GAUGE FOR SUPPLY PRESSURE 4.1-1/4" MAIN TESTAND DRAIN 5.2-1/2" AM ES C200 BFP 6.6" UNDERGROUND STUB IN BY OTHERS 7. GENERAL INFORMATION SIGN 8.21/2" BUTTERFLY VALVE 9.21/2" FORWARD FLOW BYPASS 10. 2'/" CHECK VALVE WITH BALL DRIP 11. 3" x 2'/" FIRE DEPARTMENT CONNECTION NO SCALE SECTION SAl M � 4 SCALE 1/4" = 1'-0" 114" = 1'-0 - NORTH TO CITY GRID PRESSURE HYDRANT SITE PLAN T lie 6 6-3 6 4T-3 SCOPE OF WORK DESIGN AND INSTALLA SINGLE ZONE WETAUTOMATIC FIRE SPRINKLER SYSTEM FOR THE NEW DENNY'S RESTARAUNT LOCATED AT 585 NORTH 2ND EAST REXBURG, ID 83404. MAIN FLOOR TO BE SPRINKLED PER LIGHT HAZARD OCCUPANCY EXCEPT KITCHEN AREA WHICH WILL BE SPRINKLED PER ORDINARY II HAZARD. THE HEATED COMBUSTIBLE CONCEALED SPACE SHALL BE SPRINKLED WITH BRANCH LINES RUNNING THROUGH THE WOOD TRUSSES. SYSTEM TO BE SUPPLIED BYA 6" UNDERGROUND LEAD IN INSTALLED, TESTED AND FLUSHED BY OTHERS. SYSTEM DESIGN SHALL BE IN ACCORDANCE WITH NFPA 13 2019 EDITION AND LOCAL AUTHORITY. DESIGNED BY: SEAN SMALL 208-881-5414 - OFFICE 6312 S. BURGRAFF WAY IDAHO FALLS, ID 83402 AUTHORITY HAVING JURISDICTION: STAN CRITTENDEN, MADISON FIRE DEPARTMENT 26 NORTH CENTER STREET, REXBURG, ID 83440 (208) 716-3368 GENERAL CONTRACTOR: TOD PETERSON EcoCon LLC 105 E 400 S, BURLEY, ID 83318 GENERAL NOTES 1. SYSTEM DESIGN, INSTALLATION AND TESTING SHALL BE IN ACCORDANCE WITH NFPA 13 (2019 EDITION) AND LOCAL FIRE AUTHORITY. 2. ALL MATERIALAND DEVICES TO BE U.L. LISTEDAND/OR F.M. APPROVED FOR FIRE SPRINKLER USE. 3. ALL 1" SYSTEM PIPING SHALL BE SCHEDULE 40 BLACK PIPE WITH THREADED Cl FITTINGS. 4. ALL SYSTEM PIPING 1'/4'AND LARGER SHALL BE SCHEDULE 10 BLACK PIPE WITH GROOVED FITTINGS & GROOVED RIGID COUPLINGS. 5. PIPE SHALL BE MANUFACTURED TO MEET ASTM A135 STANDARDS. CRR VALUE = 1.0 OR GREATER 6. ALL HANGERS SHALL BE DESIGNED, SPACEDAND INSTALLEDAS PER NFPA-13,2019 EDITION, CHAPTER -18. MAX LENGTH OF UNSUPPORTEDARMOVERS SHALL BE 24" (PRESSURE LESS THAN 100 PSI). 7. SPRINKLERS LOCATED IN ACOUSTICAL GRID CEILINGS SHALL BE INSTALLED CENTER OF TILE OR QUARTER POINTS. 8. ALLALARM SYSTEM, PAINTING, WIRING, FIRE EXTINGUISHERS, HYDRANTS, THRUST BLOCKING, CITY WATER CONNECTION, EXCAVATION, BACKFILLING, 24 HOUR SUPERVISION, AND SYSTEM MONITORING INSTALLATION IS BY OTHERS. 9. FLUSHING AND TESTING OF UNDERGROUND PIPING SHALL BE COMPLETED BY THE INSTALLING CONTRACTOR BEFORE CONNECTION TO THE FIRE SPRINKLER SYSTEM. 10. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE STOPPED. FIRE STOPPING MATERIAL SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTION BY OTHERS. 11. HYDRAULIC PLACARD SHALL BE POSTED ON RISER. 12. BUILDING OWNER SHALL BE RESPONSIBLE FOR ADEQUATE HEAT (40°F AND ABOVE) IN ALL WET PIPE AREAS TO PREVENT SPRINKLER SYSTEM FROM FREEZING. SYSTEM DESIGN NOTES THIS AUTOMATIC SPRINKLER SYSTEM IS SIZED BASED ON HYDRAULIC CALCULATIONS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 2019 EDITION DENSITYAREA METHOD. FIRE SPRINKLER SYSTEM IN AREAOF WORK IS DESIGNED TO LIGHT HAZARD OCCUPANCY UNLESS NOTED OTHERWISE. PERMISSIBLE DECREASES FROM NFPA 13 HAVE BEEN APPLIED TO DESIGN AREA. WATER SUPPLY DATA: STATIC PRESSURE: 80 RESIDUAL PRESSURE: 70 FLOW: 1800 DATE: 06/28/2022 SOURCE: 3-D FIRE PROTECTION FLOW TEST BUILDING DETAILS - BUILDING STRUCTURE AND CONSTRUCTION CONSISTS OF: -CONCRETE FOUNDATION -WOOD FRAMING -SHEETROCK INTERIOR WALLS -TOTAL SQUARE FOOTAGE: 8,820 FT2 MAIN LEVEL: 4,410 FT2 - 40 SPRINKLER HEADS COMBUSTIBLE CONCEALED SPACE: 4,410 FT2 - 39 SPRINKLER HEADS 00 - BUILDING CODE CLASSIFICATION - OCCUPANCY - A-2 - RESTAURANT, FOOD AND/ OR DRINK MORE THAN 50 OCCUPANTS (Q - CONSTRUCTION TYPE - V B - UNPROTECTED WOOD FRAME WATER SUPPLY INFORMATION: FLOW: 1800 GPM STATIC: 80 RESIDUAL: 70 FLOW HYDRANT 0 4 8 16 SCALE 1/16" = V-0" 1116" = 1'-0 TO CITY GRID Idaho Falls, ID Tel. 208-881-5414 Idaho License Number: FPSC-08 Sean.SmalI@3Dfire.us �]►��1► I � I :�� : I I Z�] y �I�Z�1�1 ��i I � I �: �� ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT OF 3-D FORTH IS PROJECTARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF 3-D W NETHER THE PROJECT IS COMPLETED OR NOT. REUSE OF ANY OF THE INSTRUMENTS OF SERVICE, BY THE OWNER OR EXTENSIONS OF THE PROJECT WITHOUT WRITTEN PERMISSION OF 3-D SHALL BE ATTHE OWNER'S RISKAND THE OWNER AGREES TO DEFEND, INDEMNIFY, AND HOLD HARMLESS 3-D FROM ALL CLAI MS, DAMAGES, AND EXPENSES INCLUDING ATTORNEYS' FEES ARISING OUT OF UNAUTHORIZED REUSE OF THE INSTRUMENTS OF SERVICE BY THE OWNER OR BY OTHERS ACTI NG THROUGH THE OWNER FREEZING CONDITIONS IN LOCATIONS SUBJECTTO FREEZING CONDITIONS, IT STHE OWNERS RESPONSIBILITY TO PROVIDE HEATAND ADEQUATE INSULATION THROUGHOUT WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. I have reviewed these plans and certify that they comply with the adopted N FPA standards. Nicet Name Corey Thompson NICET Level IV 116184 Date of Review 07/07/22 Signature ❑AS-BUILTVSUBMITTAL❑ OTHER REVISIONS NO. DATE DESCRIPTION LL 07/07/22 FOR APPROVAL h X L M Lo 0 0 0 A 1.% DRAWN BY SEAN SMALL 3-D FIRE PROJECT NUMBER 4CO093 CL LL LL LL LL c X W M Lo C, 0 0 6- 1.% a.+ 0 O m r Z X U_ r 00 N N N M NEEEN 'E222 NCL U U U U �aaa� c a� c a� � • t rn H ami ami a [L 0- 0 c0 LL. 6 Ui ori ui � Y IC 0) J W M M (V M II Fu 0 H CL CO CO CO CO 7 0 0 0 LSA 'a D_' Q' o_' Ix O LL d LL LL LL LML LL LL LO LO z v LO of It a� U sz s? s? SZ N N I6 f6 C of W W W N O E 1-j-9 DRAWN BY SEAN SMALL 3-D FIRE PROJECT NUMBER 4CO093 PRINT DATE 07/07/22 i U) i c X W M ,O V N 6- 1.% a.+ � O m r Z X U_ r 00 M PRINT DATE 07/07/22 Hydraulic Information Remote Area 2 OCCUPANCY CLASSIFICATION Light Hazard DENSITY (gpm/ft2) 0.10 for 1500ft2 (Actuc QUICK RESPONSE REDUCTION 12'-6 Ceiling (36.3%) TOTAL HOSE STREAMS 100.00 TOTAL HEADS FLOWING 8 K -FACTOR 5.6 TOTAL WATER REQUIRED 305.59 TOTAL PRESSURE REQUIRED 74.405 BASE of RISER (gpm) 305.59 BASE of RISER (psi) 74.405 SAFETY MARGIN (psi) +5.218 (6.6%) MAIN FLOOR SPRINKLER PLAN 1 0 2 4 SCALE 1/4" = V-0" 114" = V-0 W" Idaho Falls, ID Tel. 208-881-5414 Idaho License Number: FPSC-08 Sean.SmalI@3Dfire.us OWNERSHIP OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT OF 3-D FORTH IS PROJECTARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF 3-D W NETHER THE PROJECT IS COMPLETED OR NOT. REUSE OF ANY OF THE INSTRUMENTS OF SERVICE, BY THE OWNER OR EXTENSIONS OF THE PROJECT WITHOUT WRITTEN PERMISSION OF 3-D SHALL BE ATTHE OWNER'S RISKAND THE OWNER AGREES TO DEFEND, INDEMNIFY, AND HOLD HARMLESS 3-D FROM ALL CLAIMS, DAMAGES, AND EXPENSES INCLUDING ATTORNEYS' FEESARISING OUT OF UNAUTHORIZED REUSE OF THE INSTRUMENTS OF SERVICE BYTHE OWNER OR BY OTHERS ACTING THROUGH THE OWNER FREEZING CONDITIONS IN LOCATIONS SUBJECTTO FREEZING CONDITIONS, IT ISTHE OWNERS RESPONSIBILITY TO PROVIDE HEATAND ADEQUATE INSULATION THROUGHOUT WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. I have reviewed these plans and certify that they comply with the adopted N FPA standards. Nicet Name Corey Thompson NICET Level IV 116184 Date of Review 07/07/22 Signature ❑AS-BUILTVSUBMITTAL❑ OTHER REVISIONS NO. DATE DESCRIPTION 07/07/22 FOR APPROVAL Zh X L E Loo 000 ❑ N 00 4 DRAWN BY SEAN SMALL 3-D FIRE PROJECT NUMBER 4CO093 CLLLLLLLLL L U) c X W E Loo 000 ❑ N 00 ♦"' 0 o m r z x LL 0 N N N M NEEEN E222 Q N 7 7 7 7 WWW CL aacn� 0 V (O (O (0 (Q W LL 6 6 6 6 � Y C 0) J M M M N M II 3 0 L Cf) VJ (O (O (O (O 75 0 0 0 0 a� of 0� IY O u- dLL LL LL LL LL LL qq "t LO LID Z v LID N N I6 f6 N O DRAWN BY SEAN SMALL 3-D FIRE PROJECT NUMBER 4CO093 PRINT DATE 07/07/22 FP -02 L U) c X W M ,O V ❑ N 00 ♦"' o m r z x LL 0 oWC M PRINT DATE 07/07/22 FP -02 Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Light Hazard DENSITY (gpm/ft2) 0.10 for 1500ft2 (Actual 1337ft2) QUICK RESPONSE REDUCTION 14'-7 Ceiling (33.1%) 1003ft2 TOTAL HOSE STREAMS 100.00 TOTAL HEADS FLOWING 12 K -FACTOR 5.6 TOTAL WATER REQUIRED 299.13 TOTAL PRESSURE REQUIRED 52.674 BASE of RISER (gpm) 296.13 BASE of RISER (psi) 52.674 SAFETY MARGIN (psi) +26.971 (33.9%) r M� W T" N �7 N Q T 1 - Z0 COMBUSTIBLE CONCEALED SPACE SPRINKLER PLAN 1 0 2 4 SCALE 1/4" = V-0" 114" = V-0 Idaho Falls, ID Tel. 208-881-5414 Idaho License Number: FPSC-08 Sean.SmalI@3Dfire.us OWNERSHIP OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT OF 3-D FORTH IS PROJECTARE INSTRUMENTS OF SERVICE FOR THIS PROJECT ONLY AND SHALL REMAIN THE PROPERTY OF 3-D W NETHER THE PROJECT IS COMPLETED OR NOT. REUSE OF ANY OF THE INSTRUMENTS OF SERVICE, BY THE OWNER OR EXTENSIONS OF THE PROJECT WITHOUT WRITTEN PERMISSION OF 3-D SHALL BE ATTHE OWNER'S RISKAND THE OWNER AGREES TO DEFEND, INDEMNIFY, AND HOLD HARMLESS 3-D FROM ALL CLAIMS, DAMAGES, AND EXPENSES INCLUDING ATTORNEYS' FEESARISING OUT OF UNAUTHORIZED REUSE OF THE INSTRUMENTS OF SERVICE BYTHE OWNER OR BY OTHERS ACTING THROUGH THE OWNER FREEZING CONDITIONS IN LOCATIONS SUBJECTTO FREEZING CONDITIONS, IT ISTHE OWNERS RESPONSIBILITY TO PROVIDE HEATAND ADEQUATE INSULATION THROUGHOUT WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. I have reviewed these plans and certify that they comply with the adopted N FPA standards. Nicet Name Corey Thompson NICET Level IV 116184 Date of Review 07/07/22 Signature ❑AS-BUILTVSUBMITTAL❑ OTHER REVISIONS NO. DATE DESCRIPTION 07/07/22 FOR APPROVAL h X L2 E Loo 000 ❑ N 00 4 DRAWN BY SEAN SMALL 3-D FIRE PROJECT NUMBER 4CO093 CLLLLLLLLL L U) c X W E Loo 000 ❑ N 00 ♦"' 0 o m r z x LL 0 N N N M NEEEN E222 Q N 7 7 7 7 CL W W CL aacn� 0 V (O (O (0 (Q W LL 6 6 6 6 � Y C 0) J C M M N M II 0 L Cf) VJ (O (O (O (O 75 0 0 0 0 a� of 0� IY O u- dU- U - LL u- u- u- qq "t LO LID Z v LID N N I6 f6 N O DRAWN BY SEAN SMALL 3-D FIRE PROJECT NUMBER 4CO093 PRINT DATE 07/07/22 FP -03 L U) c X W M ,O V ❑ N 00 ♦"' o m r z x LL 0 oWC M PRINT DATE 07/07/22 FP -03