HomeMy WebLinkAboutSTAMPED FIRE WALL LETTER - 22-00699 - Mountain Archery - AdditionR&V ASSOCIATES Architecture & Interior Design Phone (208) 359-2309 Fax (208) 359-2271 1152 Bond Avenue Suite A Rexb,irg, ID 83440 www.irwa.com Brett Stoddard and Cody Jones City of Rexburg Building Department RE: Mountain Archery Fire Wall Brett and Cody, In order to form the 2 hour separation from the existing building to the new construction, find the attached details that will allow the fire wall to act as intended for the designed purpose. (see attached details) This assembly will need to cover the entire portion of wall that the existing building and the new construction connect, from floor to roof deck. In order to create the assembly, there will need to be some of the newly constructed walls to be removed to create access for the layers or dry wall and hat channel to be attached. Any penetration through this assembly will need to be closed with approved fire caulking. Sincerely, Ryan Malm Qualifications Certified By: N.C.A.R.B. - National Council of Architectural Registration Boards METAL CLAD EXTERIOR WALLS GA FILE NO. WP 9205 1 GENERIC GYPSUM WALLBOARD, GYPSUM SHEATHING, RIGID FURRING CHANNELS, STEEL GIRTS, STEEL WALL PANELS EXTERIOR SIDE: Base layer 518" type X gypsum sheathing applied at right angles to horizontal, 6" to 12" deep, "Z" or "C" shaped, 0.056" to 0.120" thick steel gifts 48" o.c. with 1 114" Type S-12 drywall screws 8" o.c. Second layer 5/8" type X gypsum sheathing applied at right angles to girls with 1 518" Type S-12 drywall screws 8" o.c. Vertical joints offset 24" from base layer joints.Face layer minimum 26 gage steel exterior wall panels applied at right angles to girls with 2" long, No. 12-14 self -drilling screws 12" o.c. Joints offset 6" from gypsum sheathing joints. INTERIOR SIDE: Base layer 5/8" type X gypsum wallboard applied parallel or at right angles to rigid furring channels 24" o.c. with 1" Type S drywall screws 24" o.c. Furring channels attached at right angles to girls with two 318" long, Type S-12 panhead screws at each girt. Face layer 518" type X gypsum wallboard applied parallel or at right angles to channels with 1 5/8" Type S drywall screws 12" o.c. Joints offset 24" from base layer joints. (LOAD -BEARING) Proposed GA no. Wall (2) LAYERS er s/a' TTPE - NEW CONSTRUCTION EXISTING METAL SMO -- HAT ---L 2A' O.G. FIRE WALL - 2 HOUR GA FILE NO. WID 3206 EXISTING IWILDINO 2 HOUR FIRE Thickness: Varies Approx. Weight: 9.5 psf Fire Test: UL R7406, R4024; 96NK36592; 8-23-99; UL Design V421 NEW HAT Z:�] 0 ANNCL 24' O.O. IN VALLEYS OF EXISTING SIDING A. McFARLAND AR-2561 �- ExISTINa SPACE SPACE MARCH 21, 2023 f21 LAYERS EXISTWO Or METAL STATE OF IDAHO TYPE 'X' WALLING WALL Proposed construction gypsum board to be attached as per GA file description.