Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 23-00021 - 561 Twisted Willow - Solar PanelsAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : 561 Twisted Willow - Solar Panels Address : 561 Twisted Willow Record Type : Solar Panels Document Filename : Daman Reynolds PROJ-2563 SS.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00021 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments PV-1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector PV-2 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector PV-2 Rectangle Larry Beesley : Building Open 2 PV-2 Free Text Larry Beesley : Building Open 2 3' 3' PV-1 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector PV-3 Stamp Alex Owens : Electrical Open 3 Approved - Electrical Inspector PV-3 Free Text Alex Owens : Electrical Open 3 Please call 208-716-1330 for rough inspection when all rooftop equipment is on site and prior to installation on roof. Solar Panels Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) P L A N S E T L E G E N D S H E E T I N D E X V I C I N I T Y M A P A P P L I C A B L E C O D E S A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N P V - 1 C O V E R P A G E P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 E L E C T R I C A L C A L C U L A T I O N S P V - 5 R E Q U I R E D S I G N A G E COVER PAGE ISSUED FOR: PERMIT DATE 01/19/2023 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DAMAN REYNOLDS DESIGNED BY CONTRACTOR INFORMATION P V - 1 561 TWISTED WILLOW RD., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ ( E ) E X I S T I N G ( N ) N E W E X T E X T E R I O R I N T I N T E R I O R E M T E L E C T R I C A L M E T A L L I C T U B I N G R M T R I G I D M E T A L L I C T U B I N G F M C F L E X I B L E M E T A L L I C C O N D U I T V O C V O L T A G E O P E N C I R C U I T V M P V O L T A G E A T M A X . P O W E R I S C S H O R T C I R C U I T C U R R E N T I M P C U R R E N T A T M A X . P O W E R N T S N O T T O S C A L E MSPSUBACDCSLCMINVJBCBBAT M A I N S E R V I C E P A N E L S U B S E R V I C E P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X B A T T E R Y P V P R O D U C T I O N M E T E R R A P I D S H U T D O W N D I S C O N N E C T PMRSD D A M A N R E Y N O L D S 5 6 1 T W I S T E D W I L L O W R D . , R E X B U R G , I D 8 3 4 4 0 2 1 - U R E F B M 4 0 0 M F G - B B ( 4 0 0 W ) P H O T O V O L T A I C M O D U L E S 1 - S O L A R E D G E S E 7 6 0 0 H - U S W I T H P R I S M T E C H N O L O G Y ( 7 6 0 0 W ) I N V E R T E R ( S ) S Y S T E M S I Z E : 8 . 4 0 0 K W D C S T C A R R A Y A R E A : 4 4 1 . 9 3 S F 1.ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2.ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3.LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4.ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5.ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6.ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7.SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8.DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALLLOCAL ORDINANCES AND POLICIES.9.THE PROJECT HAS BEEN DESIGNED TO WITHSTAND AMINIMUM 110 MPH WIND LOAD.10.THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITYIS OBTAINED.11.IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLEGROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE.12.EACH MODULE WILL BE GROUNDED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE ANDTHE MANUFACTURERS INSTALLATION INSTRUCTIONS.13.A LADDER SHALL BE IN PLACE FOR INSPECTION INCOMPLIANCE WITH OSHA REGULATIONS.14.PROPER ACCESS AND WORKING CLEARANCE WILL BEPROVIDED "WARNING: PV POWER SOURCE" TO BE PLACEDEVERY 10 FT.15.GFCI PROTECTION IN INVERTER. A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C / I R C / I F C 2 0 1 8 C O D E ADDITIONAL NOTESOCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED ALL CONDUIT TO RUN ON EXTERIOR OF HOUSE UNLESSOTHERWISE NOTED COVER PAGE1-23-2023 MSP ACINVMTR A E R I A L V I E W SITE PLAN, AERIAL VIEW N ISSUED FOR: PERMIT DATE 01/19/2023 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DAMAN REYNOLDS DESIGNED BY CONTRACTOR INFORMATION P V - 2 561 TWISTED WILLOW RD., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ R O O F D E S C R I P T I O N R O O F A R R A Y P I T C H A Z I M U T H # 1 3 3 ° 1 8 0 ° # 2 3 3 ° 9 0 ° SITE PLANPROPOSED SYSTEMDC SIZE / AC SIZE:8.400 KW-DC / 7.600 KW-ACTOTAL # OF PANELS:21 A B B R E V I A T I O N S S C A L E : N T S S C A L E : N T S ROOF TYPE:SHINGLE PANEL PLACEMENT MAY DIFFER FROMAPPROVED DESIGN DUE TO UNFORESEENOBSTRUCTIONS OR PERMITTING SETBACKS TOTAL # OFMODULESTOTAL ARRAYAREA(Sq. Ft.)TOTA L R O O F A R E A (S q . F t . ) R O O F A R E A C O V E R E D B Y A R R A Y ( % ) 21441.9333 4 2 . 7 6 1 3 . 2 2 S O L A R P V M O D U L E I N V I N V E R T E R M S P M A I N S E R V I C E P A N E L A C A C D I S C O N N E C T M T R M E T E R 3 F T / 1 8 I N C H F I R E S E T B A C K AC DISCONNECTWITHIN 3’ FROM UTILITY METERTWISTED WILLOW RD. R O O F # 1 R O O F # 2 1-23-2023 3 ' 3 ' E L E C T R I C A L N O T E S SINGLE LINE DIAGRAM R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) ISSUED FOR: PERMIT DATE 01/19/2023 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DAMAN REYNOLDS DESIGNED BY CONTRACTOR INFORMATION P V - 3 561 TWISTED WILLOW RD., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . M O D U L E : U R E F B M 4 0 0 M F G - B B ( 4 0 0 W ) V o c = 3 7 . 2 0 V I s c = 1 3 . 6 8 A V m p = 3 1 . 1 7 V I m p = 1 2 . 8 4 A P R O P O S E D S Y S T E M D C S I Z E / A C S I Z E : 8 . 4 0 0 K W - D C / 7 . 6 0 0 K W - A C 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N 2 9 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 1 ) ( B ) ELECTRICAL SINGLE LINE DIAGRAMELECTRICA L E Q U I P M E N T C A L L O U T S 8,400W TOTAL SOLAR ARRAY21 URE FBM400MFG-BB (400W) PANELS1 STRING OF 11 MODULES CONNECTED IN SERIES @ INVERTERWIRE AND CONDUIT CALLOUTS SOLADEC K M O D E L 0 7 8 3 - 4 1 J U N C T I O N BOX/ROO F P E N E T R A T I O N , SOLARED G E S E 7 6 0 0 H - U S W I T H P R I S M TECHNOL O G Y I N V E R T E R U N G R O U N D E D , NEMA 3R, U L L I S T E D , (W/ INTEG R A T E D D C D I S C O N N E C T ) WITH INTE G R A T E D G F P , W / I N T E G R A T E D A F P (2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT/FMC(2) #8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT ABCDEF1 STRING OF 10 MODULES CONNECTED IN SERIES @ INVERTERSQUARE D S A F E T Y S W I T C H , # D U 2 2 2 R B 250 VAC, 6 0 A , N E M A 3 R , N O N - F U S E D , U L , NEMA, CS A , N O M C E R T I F I E D 123(E) MAIN S E R V I C E P A N E L (W/ (E) 200 A M A I N B R E A K E R T O P F E D ) 200A, 1Ø, 2 4 0 V 40AE BACKFEED 26SQUARE D BREAKERNG200A FL1L2NGD3L1L2NGBA T T E R Y DC I N P U T _~M P P T 1 M P P T 2 3C 1 1 M O D U L E S I N S E R I E S B A 2 1 O N E P E R P A N E L 1 0 M O D U L E S I N S E R I E S A B O N E P E R P A N E L 2 1 S T R I N G 1 S T R I N G 2 1ELECTRICAL LINE DIAGRAMPV-3SCALE: NTS (2)#10 AWG PV/RHW-2 IN FREE AIR(1)#6 AWG BARE COPPER GND IN FREE AIRBI-DIRECTI O N A L U T I L I T Y M E T E R 200A, 1Ø, 2 4 0 V 6 0 0 V 7.6kW, 240 V A C , 3 2 A , 440W, 100 0 V D C SOLARED G E S 4 4 0 O P T I M I Z E R O N E P E R P A N E L N O B A T T E R Y B A C K U P T O B E I N C L U D E D W I T H T H I S P E R M I T AC DISCONNECTWITHIN 3’ FROM UTILITY METER P l e a s e c a l l 2 0 8 - 7 1 6 - 1 3 3 0 f o r r o u g h i n s p e c t i o n w h e n a l l r o o f t o p e q u i p m e n t i s o n s i t e a n d p r i o r t o i n s t a l l a t i o n o n r o o f . ISSUED FOR: PERMIT DATE 01/19/2023 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DAMAN REYNOLDS DESIGNED BY CONTRACTOR INFORMATION P V - 4 561 TWISTED WILLOW RD., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ ELECTRICAL CALCULATIONS ELECTRICAL CALCULATIONSDC CONDUCTOR AMPACITY CALCULATIONS:MAX # OF STRINGS PER SET OF DC CONDUCTORS: 2EXPECTED WIRE TEMP (°C): +22°C Correction: 55°CTEMP CORRECTION PER TABLE 310.16: 0.76OF CURRENT CARRYING CONDUCTORS: 2CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a): 1CIRCUIT CONDUCTOR SIZE: #10 AWGCIRCUIT CONDUCTOR AMPACITY: 30 AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B):1.25 x 1.25 x Isc x # OF STRINGS PER OPTIMIZER: 15 ADERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16:TEMP CORR. PER NEC TABLE 310.16 x CONDUIT FILL CORR. PER NEC310.15(B)(3)(a) x CIRCUIT CONDUCTOR AMPACITY:0.76 x 1 x 30 = 22.80A > 17.10A STRINGS 1 - 2OPERATING VOLTAGE = 1 x 31.17VTOTAL OPERATING CURRENT = 1 x 9.17AMAX PV CONTINUOUS CURRENT PER NEC 690.8(A)(1):1.25 x Isc x # BRANCHES1.25 x 13.68 = 17.10AAC CONDUCTOR AMPACITY CALCULATIONS:# OF INVERTERS: 1EXPECTED WIRE TEMP (°C): 33°CTEMP CORRECTION PER TABLE 310.16: 0.96AWG CIRCUIT CONDUCTOR SIZE: #8# OF CURRENT CARRYING CONDUCTORS: 3CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 1CIRCUIT CONDUCTOR AMPACITY: 50AREQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B):1.25 x MAX INVERTER OUTPUT CURRENT x # OF INVERTERS1.25 x 32 x 1 = 40.00ADERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16:TEMP CORR. PER NEC TABLE 310.16 x CONDUIT FILL CORR. PER NEC310.15(B)(3)(a) x CIRCUIT CONDUCTOR AMPACITY :0.96 x 1 x 50 = 48.00A > 40.00A <= 40A OCPD T O T A L A R R A Y A C C O N D U C T O R A M P A C I T Y C A L C U L A T I O N S ( F R O M A R R A Y T O M S P ) : # O F I N V E R T E R S : 1 C I R C U I T C O N D U C T O R S I Z E : # 8 # O F C U R R E N T C A R R Y I N G C O N D U C T O R S : 3 C O N D U I T F I L L C O R R E C T I O N P E R N E C 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) : 1 C I R C U I T C O N D U C T O R A M P A C I T Y : 5 0 A R E Q U I R E D C I R C U I T C O N D U C T O R A M P A C I T Y P E R N E C 6 9 0 . 8 ( B ) : 1 . 2 5 x M A X I N V E R T E R O U T P U T C U R R E N T x # O F I N V E R T E R S 1 . 2 5 x 3 2 x 1 = 4 0 . 0 0 A A M A I N D I S C O N N E C T : 2 0 0 A N E W S O L A R S Y S T E M F U S E / O C P D : 4 0 A MAX PV VOLTAGE & CURRENT CALCULATIONS:RECORD LOW TEMP (°C): -26°CVOLTAGE CORRECTION PER NEC 690.7: 1.23MAX PV SYSTEM VOLTAGE PER NEC 690.7: 37.20 VVcorrection x Voc x # MODULES IN SERIES PER OPTIMIZER 400V REQUIRED SIGNAGE ISSUED FOR: PERMIT DATE 01/19/2023 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM DAMAN REYNOLDS DESIGNED BY CONTRACTOR INFORMATION P V - 5 561 TWISTED WILLOW RD., REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ REQUIRED SIGNAGE 2. LABEL FOR SOLAR AC DISCONNECT: S Y S T E M A C V O L T A G E : 2 4 0 V T O T A L R A T E D A C A M P S : 4 0 A S Y S T E M A C V O L T A G E : 2 4 0 V 3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8"HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITALLETTERS, WHITE ON RED BACKGROUND AND A REFLECTIVE,WEATHER RESISTANT MATERIAL.1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 1/4"HIGH LETTERING PER NEC 690-17.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING: FOLLOWING WORDING:THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.CUSTOMER OWNEDON SITE POWER GENERATIONSYSTEM DISCONNECT D I R E C T C U R R E N T P H O T O V O L T A I C S O U R C E S Y S T E M A C V O L T A G E : 2 4 0 V M A X A C C I R C U I T C U R R E N T : 3 2 A M A X D C C U R R E N T P E R O P T I M I Z E R : 1 5 A 8. T H E F O L L O W I N G S I G N M U S T B E P R O V I D E D O N T H E O U T S I D E ( O R W I T H I N 3 ' O F ) T H E S E R V I C E P A N E L B O A R D , A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 1 ) : R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N A L L S I G N A G E M U S T B E P E R M A N E N T L Y A T T A C H E D A N D B E W E A T H E R R E S I S T A N T / S U N L I G H T R E S I S T A N T A N D C A N N O T B E H A N D - W R I T T E N . N E C 1 1 0 . 2 1 ( B ) FIRE DEPARTMENT REQUIRED SIGNAGE4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:5. LABEL INSTALLATION AT INTERCONNECT BREAKER:10 . S I G N A G E R E Q U I R E D A T S T R I N G I N V E R T E R P E R N E C 6 9 0 . 5 3 : 9. S I G N A G E R E Q U I R E D A T S E R V I C E P A N E L B O A R D P E R N E C 6 9 0 . 5 4 : 7. A T P V D I S C O N N E C T S W I T C H A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 3 ) : 6. R E F L E C T I V E P L A C A R D A T S E R V I C E S T A T I N G : "SOLAR AC DISCONNECT"WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALSON BOTH THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION.WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE. 1 0 . A T E V E R Y E N C L O S U R E , E V E R Y 1 0 ’ A L O N G C O N D U I T O R M C C A B L E , A N A T E A C H S I D E O F W H E R E T H E C O N D U I T O R C A B L E P A S S E S T H R O U G H A W A L L , F L O O R , O R A N Y O T H E R P A R T I T I O N . W A R N I N G : P H O T O V O L T A I C P O W E R S O U R C E T H E M A R K I N G S S H A L L B E P E R M A N E N T L Y A F F I X E D A N D V I S I B L E A F T E R I N S T A L L A T I O N P E R N E C 6 9 0 . 3 1 ( G ) ( 3 - 4 ) . WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEM