HomeMy WebLinkAboutCOMCHECK - 22-00630 - Bodifi - AdditionCOMcheck Software Version 4.1.5.4 Envelope Compliance Certificate Project Title: 2018 IECC Project Type:Addition Vertical Glazing / Wall Area:3% Location:Rexburg, Idaho Climate Zone:6b Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: Building Area Floor Area 1-Exercise Center : Nonresidential 11718 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1: Metal Building, Screw Down, Liner System without Thermal Blocks, [Bldg. Use 1 - Exercise Center] 11718 0.0 35.0 0.028 0.031 Floor 1: Slab-On-Grade:Unheated Fully insulated (uniform R-value across perimeter + under entire slab), [Bldg. Use 1 - Exercise Center] (c) 340 ---10.0 0.360 0.540 NORTH Exterior Wall 1: Solid Concrete:10" Thickness, Normal Density, Furring: None, [Bldg. Use 1 - Exercise Center] 100 ---2.0 0.255 0.080 Exterior Wall 4: Metal Building Wall, Single Layer Mineral Fiber (in cavity, thermal block at girt), [Bldg. Use 1 - Exercise Center] 2163 30.0 0.0 0.052 0.052 Door_North_Man: Insulated Metal, Swinging, [Bldg. Use 1 - Exercise Center] 21 ------0.340 0.370 Door_North_Overhead: Insulated Metal, Garage door 14% glazing, [Bldg. Use 1 - Exercise Center] 70 ------0.340 0.310 EAST Exterior Wall 2: Solid Concrete:10" Thickness, Normal Density, Furring: None, [Bldg. Use 1 - Exercise Center] 120 ---2.0 0.255 0.080 Exterior Wall 5: Metal Building Wall, Single Layer Mineral Fiber (in cavity, thermal block at girt), [Bldg. Use 1 - Exercise Center] 2694 30.0 0.0 0.052 0.052 WEST Exterior Wall 3: Solid Concrete:10" Thickness, Normal Density, Furring: None, [Bldg. Use 1 - Exercise Center] 120 ---2.0 0.255 0.080 Exterior Wall 6: Metal Building Wall, Single Layer Mineral Fiber (in cavity, thermal block at girt), [Bldg. Use 1 - Exercise Center] 2345 30.0 0.0 0.052 0.052 Window: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID 550, SHGC 0.33, [Bldg. Use 1 - Exercise Center] (b) 240 ------0.340 0.360 Door_East_Man: Insulated Metal, Swinging, [Bldg. Use 1 - Exercise Center] 21 ------0.340 0.370 Door_West_Man: Insulated Metal, Swinging, [Bldg. Use 1 - Exercise Center] 21 ------0.340 0.370 Project Title: Data filename:S:\Drawings\893 Bodifi Addition Rexburg\ComCheck.cck 09/28/22Report date: 101 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.4 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 4% better than code Project Title: Data filename:S:\Drawings\893 Bodifi Addition Rexburg\ComCheck.cck 09/28/22Report date: 102 ofPage