HomeMy WebLinkAboutCONCRETE FIELD TEST 8 - 22-00269 - Hibbard Elementary SchoolFile name: 22229FB02152023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EBD20BCD-BF0F-4344-BCE0-BEA0EF8C4E87 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-229 Cumulative Test Load Amount: 6.5 Project Name: Hibbard Elementary Test Location: South wall Client: Madison School District Admixtures: ZYLA, Air ENTMNT Ticket Number: 328890 Contractor: M-L Masonry Supplier: Burns Mix Number: 7042169 Date: 2/8/2023 Cylinder Log #: 52 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 0.0 Entrained Air Spec. (%): Concrete Temperature (°F): 68 Ambient Temperature (°F): 26 Unit Weight (PCF): 0 Tested By: M.Mansfield Date: 2/8/2023 Picked Up By: E. Vail Date: 2/9/2023 Time: 3:00 PM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/15/2023 3.500 9.62 57,450.0 5972 4,000.0 Type 2 Date: 02/15/2023 Reviewed By: Luke Hammar Signature: