HomeMy WebLinkAboutPLANS - 23-00052 - 208 Physical Therapy - Remodel2 0 8 PHYSICAL THERAPY LLC
41 $ 1 a M I ;a 4:01k!j a A
al 0 k ii 0 - rt - -
REXBURG,
VICINITY MAP
PROJECT SITE
1120 STOCKS AVE
REXBURG, IDAHO
IDAHO
GENERAL NOTES
1. CONTRACTOR SHALL COMPLY WITH ALL IBS 2018 CODE REQUIREMENTS.
2. ALL CONSTRUCTION TO BE TO CURRENT ADOPTED CODES AND REGULATION
OF REXBURG.
3. ALL PROJECT CONSTRUCTION TO MEET CURRENT ANSI, ADA—AG, AND IBC
REQUIREMENTS, INCLUDING SIGNAGE, DOOR HARDWARE, CLEARANCES, AND
OTHER REQUIREMENTS.
6. DO NOT SCALE DRAWINGS.
7. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF SUBCONTRACTORS
AND WORK.
8. MAXIMUM SLOPE AT DOOR LANDINGS AND CROSS SLOPE SHALL NOT
EXCEED 2%
9. EXIT LIGHTING AND EXIT SIGNS SHALL COMPLY WITH SECTION 1008 AND
1013.
DRAWING INDEX
DRAWING
No.
GENERAL
G1.0
COVER SHEET & INDEX TO DRAWINGS
G1.1
CODE SHEET, STANDARD ADA REQUIREMENTS
O
D1.1
DEMO FLOOR PLAN
D
ARCHITECTURAL
A1.1
MAIN FLOOR PLAN
Q
0
�i PROFIT AVE
m
m
a
oe i
x
� w
G:
DIVIDEND DR. Qe�g
\Oe
U¢
�
0
y
®N
SITE3
x
I
w
z
w
N
pry a
Q
o
z
0
m
33 REXBURG
N
tie
NORTH
CONSULTANTS:
IDAHO
GENERAL NOTES
1. CONTRACTOR SHALL COMPLY WITH ALL IBS 2018 CODE REQUIREMENTS.
2. ALL CONSTRUCTION TO BE TO CURRENT ADOPTED CODES AND REGULATION
OF REXBURG.
3. ALL PROJECT CONSTRUCTION TO MEET CURRENT ANSI, ADA—AG, AND IBC
REQUIREMENTS, INCLUDING SIGNAGE, DOOR HARDWARE, CLEARANCES, AND
OTHER REQUIREMENTS.
6. DO NOT SCALE DRAWINGS.
7. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF SUBCONTRACTORS
AND WORK.
8. MAXIMUM SLOPE AT DOOR LANDINGS AND CROSS SLOPE SHALL NOT
EXCEED 2%
9. EXIT LIGHTING AND EXIT SIGNS SHALL COMPLY WITH SECTION 1008 AND
1013.
DRAWING INDEX
DRAWING
No.
GENERAL
G1.0
COVER SHEET & INDEX TO DRAWINGS
G1.1
CODE SHEET, STANDARD ADA REQUIREMENTS
DEMO
D1.1
DEMO FLOOR PLAN
ARCHITECTURAL
A1.1
MAIN FLOOR PLAN
Q
0
Wco0
Q
0
m
m
x
� w
G:
U¢
®N
I
w
z
w
pry a
o
z
0
m
N
CONSULTANTS:
0
v
Q
�z
JU
�
DC
�O
�z
lu
l
003~
ju
o
>
�
�
o
J
C-)
CD
Z
O
Q
0
REVISION:
DRAWN BY:
JOB NO:
BAM
CHECKED
BY:
DATE:
RZSM
FEB. '23
PLOT DATE: 2-10-23
DRAWING NO.
FlLE: 090 -G1.0
-CS * G1.0
G1.1
OF
2
2'-6"
2'-6" z MIN GLR LG�10
MIN GLR A3 41" MAX WIDTH
17" MIN WIDTH A3 3q" MIN � E D :]
Iq" MAX AIMIN B F Z 36" GRAB BAR
lo 6" MAX 56" MIN � � 17" MIN ff
A2 A2 42" GRAB BAR
D
_ x
zi
z O r O �' G Z i z z TNSULATE ALL EXPOSED z z TO DISPENSING w�,e A3 IS" GRAB BAR
_ - - z PIPES z - OUTLET
O
- _ B PAPER TOWEL DISPENSER
FIN. FLR cry m I J m m m m cv N N N m REACH m o
z
CLEARANCE CLEARANCE TOILET PAPER HOLDER
z —
6" MAX TOE 8" MIN KNEE I'-6" I'-6" :f 36" MAX
CLEARANCE CLEARANCE D MIRROR
MIN GLR
0
® WALL LAYATORY, MIRROR 4 TOILET SEAT ELECTRIC, WASTE SOAP DISPENSERLf
DRINKING SOAP DISPENSER COKER DISPENSER HAND DRYER RECEPTACLE °O
FOUNTAIN URINAL WATER CLOSET WATER CLOSET E WASTE RECEPTACLE W o
0
STAN=l ARO HE I ISHT RMOU I REMENTS
SCALE: I/4 - I -O x
e W
GENERAL NOTES & U
E 12 min E STANDARD ACCESSIBILITY ® N
W
00
Ld
18 min 1. GRAB BARS MUST NOT ROTATE WITHIN THEIR FITTIN65
32 min 32 min 32 min 2. FLUSH VALVE HANDLE ® 44" MAX AFF (ON WIDE SIDE OF TOILET o
E \ � WHERE APPL I GABLE)
CD
3. PROVIDE A MIN. CLEAR FLOOR SPACE OF 30X48 WITH Iq" MAX. m
36 min EXTENDING UNDER LAVATORY/DRINKING FOUNTAIN TO INSULATED
PIPING/ PLUMBING.
�O 4. 5 LB5 MAX FORGE TO OPERATE FLUSH VALVE 4 ACTIVATE
CONTROLS
5. ITEMS SHOWN HERE ARE FOR INFORMATION ONLY. GENERAL
\ \ CONTRACTOR TO VERIFY ALL APPLICABLE ITEMS 8 MOUNT PER CONSULTANTS:
ADA REQUIREMENTS WHERE APPLICABLE.
6. FAUCETS MUST BE LEVER TYPE, ELECTRONICALLY ACTIVATED, OR
APPROVED SELF - CLOSING VALVES (MIN. 10 SEG OPEN FLOW),
AND BE OPERABLE NONE HAND, NOT REQUIRING T16HT GRASPING,
PINGHIN6 OR TWWR
TWISTING OF IST.
(A) (B) (C) A (B) (C) (D) 7. ALL DOORS IN THE PUBLIC, AND COMMON USE AREAS SHALL
front approach, pull side front approach, push side front approach, push side, door hinge approach, pull side COMPLY WITH AN51 A117.1 INGLUDIN6 NECESSARY MANEUVERING
hinged door sliding door folding door CLEARANCES AND ACCESSIBLE DOOR HARDWARE
provided with both closer and latch 6. ALL DOORS SHALL HAVE 32" MIN. CLEAR WIDTH WHEN DOOR 15
BOOR OFEN, I N,G A 117TH REOU I REMENTS CLEARANCE AT = 0OOR APPROACH ALL LUCIO BINDPEOFI 5
q. ALL PLUMBING FIXTURES 4 APPLIANCES SHALL HAVE MIN. 30" X
48" CLEAR FLOOR SPACE
SCALE: N.T.S. SCALE: N.T.S. 10. ALL PLUMBING FIXTURES, APPLIANCES 4 TELEPHONES IN PUBLIC
AND COMMON USE AREAS SHALL COMPLY WITH A.D.A., IBC AND
ANSI 117.1
v 60" MIN
E 22 min E 22 min
00
N
Fi--
I6" MIN. I6" MIN. 42" MIN 16-18"
24 min E 16" MIN. 36" 6"
Lv N
42 min
24 min 24 min
� E E
co
�r
F G (H) (I) J \ =
hinge approach, pull side hinge approach, push side hinge approach, push side, door latch approach, pull side latch approach, pull side, latch approach, push side
provided with both closer and latch door provided with closer - O
CLEARANCE AT = CCR APPROACH M," � v Q v
SCALE: N.T.S. (z X�
30 48
30x48 _
lu
24 min 00 18 minIU
v
c E4>\ E O
E \%
i7r=MO FLOOR PLAN
5GALE: 1/4" = 1'-0"
'MOTES
OI REMOVE WALLS IN THIS LOCATION
O2 REMOVE HALF WALLS IN THI5 LOCATION
O REMOVE EXISTING DOORS
O REMOVE EXTERIOR WINDOW AND PREP OPENING FOR
NEW DOOR
O5 REMOVE SHEET ROCK IN THIS AREA PREP FOR NEW
PLUMBING
O REMOVE ELECTRICAL AS NEEDED FOR WALL
REMOVAL. ALL ELECTRICAL WORK TO BE TO CODE
W 1 TH ALL TERM I NAT 1 ONS AND JUNCTION BOXES. FIRE
ALARM SYSTEM TO REMAIN INTACT. PROVIDE EXIT
516N5 AS NEED FOR NEW ENTRANCE
Q
w
0
w
Q
w
u
Q
w
0
z
w
z
0
U
Z
W
F-
H
3
O
S
F-
3
Q
w
A
H
0
z
LD
0
w
A
Vi
Ul
z
H
3
A
0
w
D
A
w
N
ti
O
2
F --
Q
Z
r
z
a
J
O
Z
O
U
A
Z
Q
S
w
Z
3
0
J
Q
F-
I --
0 0
Z_
Q
H
w
F-
u C_)
W
S
U
Q
W
2
A
Z
Q
H
2
r
0
U
r
W
A
W
u
W
O
W
Q
Z
w
Q
A
z
LD
Z_
3
Q
A
U
J
J
W
H
Q
U
O
V)
Q
3
0
W0
¢
0
< M C
�
X
� w
U¢
0I
�A z
z
w
N ¢
NzO
O]
CONSULTANTS:
v
y
JUl
O
V
v J�
■-. ■
t O
W O
O
N
[Q W O
U Z
uj
C)
REVISION:
DRAWN BY: JOB NO:
RSM
CHECKED BY: DATE:
RSM FEB. 125
PLOT DATE: 2-10-23
DRAWING NO.
FILE: 090 -D1.1 -DFP * D1.1
SIJ
OF
FLOOR PLAN
5GALE: 1/4" = 1'-0"
NOTE5
OI
IN FILL AALL5 IN THESE LOCATIONS
O PREP FLOOR FOR NEA FLOOR FIN 15H
O NEA VgALL
O4 PROVIDE NEA DOOR IN TH 15 LOCATION
OS PROVIDE NEA PLUMBING
O6 ALL ELECTRICAL AORK TO BE TO CODE AITH ALL
TERMIN4TION5 AND JUNCTION BOXES. FIRE ALARM
SYSTEM TO REMAIN INTACT. PROVIDE EXIT 5I&N5 A5
NEED FOR NEA ENTRANOE
Q
W
0
W
Q
u
W
u
Q
W
S
0
z
w
z
0
U
Z
W
F-
H
3
O
S
F-
3
Q
W
A
H
0
z
LD
0
w
A
V
Ul
z
H
3
A
0
w
D
A
w
N
ti
O
2
F --
Q
Z
r
z
a
J
O
Z
O
U
A
Z
Q
S
W
Z
3
0
J
Q
F-
I --
0 0
Z_
Q
H
W
F-
u C_)
W
S
U
Q
W
S
A
Z
Q
H
S
r
0
U
r
W
A
W
u
W
O
W
Q
Z
W
Q
A
z
LD
Z_
3
Q
A
U
J
J
W
H
Q
U
O
V)
Q
3
0
�C�'
W0
¢
0
< m c
�
. w
U¢
N
®� w
�® z
z
w
N � ¢
Nz0
O]
Lo
CONSULTANTS:
v
JU
I
O
TZv
V.
l
■
O
CD
uj
W O
� O
V Z
IL
REVISION:
DRAWN BY: JOB NO:
RSM
CHECKED BY: DATE:
RSM FEB. '23
PLOT DATE: 2-10-23
DRAWING NO.
FILE: 090 -A1.1 -FP * AM
ALI
OF