HomeMy WebLinkAboutOUTDOOR EVACUATION SIGNALS - 23-00065 - 7N Apartments - Bldg 1 - Fire AlarmWGES / WGEC Series Outdoor Evacuation Signals 24 VDC Outdoor Commander Strobe and Horn/Strobe 1 unit per carton, 3 pounds per carton Assembled in the USA Applications The Outdoor Commander Series is a outdoor listed strobe and horn/strobe comination that offers dependable visible and/or audible alarms for all outdoor needs. The WGE Series offers a fixed 75 candela strobe. The WGEC horn/strobe offers a continuous or synchable temporal 3 in 2400Hz, mechanical and chime as well as a whoop tone. All tones are easy for the professional to change in the field by the use of switches. Included with the WGE Series is the GOE or GOELP outdoor enclosure. The enclosure is made of high quality Lexan® material, providing protection from weather related conditions and allowing the necessary full candela output. This highly constructed enclosure meets various installation requirements including deterring moisture from entering the enclosures. The Outdoor Commander Series is equipped with a standard 4” mounting plate which incorporates the Super-Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The WGE Series also features the Checkmate® instant voltage verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The WGE Series appliances are ANSI/UL 464, ANSI/UL 1638, CAN/ULC S525 and/or CAN/ULC S526 listed for use with fire protective systems and are warranted for three years from date of purchase. Standard Features • Nominal voltage 24 VDC • Fixed 75 candela • GOE Unit Dimensions: 5.84” (14.83 cm) high x 4.81” (12.22 cm) wide x 4.22” (10.72 cm) deep • GOELP Unit Dimensions: 5.84” (14.83 cm) high x 4.81” (12.22 cm) wide x 3.25” (8.255 cm) deep • Super-Slide® - Ease of Supervision Testing • Checkmate® Instant Voltage Verification • Prewire entire system, install mounting bracket, then install signals • Input terminals accept 12 to 18 AWG • Horn/strobe switch selection for high or low dBA • Horn/strobe switch for 2400 Hz, mechanical, chime and whoop tones • Horn/strobe switch for continuous or temporal 3 (not available on whoop tone) • Synchronize strobe and/or horn by using Gentex AVSM Control Module • Silence audible while visual appliance will remain flashing • Tamperproof re-entrant grill and locking screw (optional use) • GOE/GOELP made of clear Lexan® - provides maximum visibility and reliability for effective visible signaling - allowing full 75cd output • Faceplate available in red or off-white • Wall mount Product Listings • ANSI/UL 464 and ANSI/UL 1638 Listed • CAN/ULC S525 and/or CAN/ULC S526 Listed • CSFM: 7135-0569:122 (WGEC) 7125-0569:127 (WGES) 7300-0569:124 (ENCLOSURE) • MEA: 285-91E-XVI Product Compliance • NFPA 72 • Americans with Disabilities Act (ADA) • IBC/IFC/IRC • Quality Management System is certified to: ISO 9001:2008 WGES / WGEC - Outdoor Evacuation Signals NOTE: Must order the GOE or GOELP (sold separately) when using the GEH24 in an outdoor application. WGE 24 VDC Series Strobe Current Ratings Candela 24 VDC UL Max 75 cd 112 mA 170 mA * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). R = Red Faceplate, W = White Faceplate LP = Low Profile (GOELP Enclosure) All units are available in plain (no lettering) Plain units are not returnable WGES / WGEC is shipped with the GOE or GOELP Outdoor Enclosure GEH Low Profile Evacuation Horn Model Part Number Voltage (VDC) Reverberant dBA at 10ft. Anechoic Room dBA at 10ft. GEH24-R 904-1205-002 24 70-82 dBA 100 dBA GEH24-W 904-1207-002 24 70-82 dBA 100 dBA WGES24 Evacuation Outdoor Strobe Model Part Number Voltage (VDC)Candela WGES24-75WR 904-1219-002 24 75 WGES24-75WW 904-1220-002 24 75 WGES24-75WRLP 904-1261-002 24 75 WGES24-75WWLP 904-1263-002 24 75 WGEC24 Evacuation Outdoor Horn/Strobe Model Part Number Voltage (VDC)Candela Reverberant dBA at 10ft. Anechoic Room dBA at 10ft. WGEC24-75WR 904-1217-002 24 75 70-82 dBA 100 dBA WGEC24-75WW 904-1218-002 24 75 70-82 dBA 100 dBA WGEC24-75WRLP 904-1257-002 24 75 70-82 dBA 100 dBA WGEC24-75WWLP 904-1259-002 24 75 70-82 dBA 100 dBA WGE 24 VDC Horn Decibel (dBA) and Current Ratings (mA) Horn Decibel Levels (dBA) Horn Current Ratings (mA) Horn Mode Minimum SPL at 10ft. per ANSI/UL 464 (HIGH) Minimum SPL at 10ft. per ANSI/UL 464 (LOW) UL MAX Regulated 24 VDC Operating Current (HIGH) Temp 3 2400Hz 78 dBA 71 dBA*28 mA Temp 3 Mechanical 76 dBA 70 dBA*25 mA Temp 3 Chime 70 dBA*66 dBA*15 mA Continuous 2400Hz 81 dBA 74 dBA*28 mA Continuous Mechanical 80 dBA 72 dBA*25 mA Continuous Chime 70 dBA*66 dBA*15 mA Whoop 82 dBA 69 dBA*56 mA 4.81” 12.22 cm 4.22” 10.72 cm 5.84” 14.83 cm Gentex Super-Slide® Mounting Bracket Allows the installer to prewire the system, test for system supervision, remove the signal head until occupancy, switch out Gentex signals without changing mounting brackets and has locking edge connector for snap-in-place installation. Gentex Checkmate® Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. Notice: Care should be taken to not short the test probes. Notes • The WGE Series is listed for outdoor use. Indoor operating temperature: 32° to 120°F (0° to 49°C). Outdoor operating temperature: -31° to 150°F (-35° to 66°C) • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode, its sound pressure is the same as the continuous mode. • This appliance is not recommended for use on coded or pulsing signaling circuits Fire Protection Products Group | 10985 Chicago Drive | Zeeland, MI 49464 gentex.com | Phone: 616.392.7195 | Toll-free: 800.436.8391 | Fax: 616.392.4219 551-0047-04 Architect & Engineering Specifications The audible and/or visible signal shall be Gentex WGES, WGEC Outdoor Evacuation Signal Series or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSI/UL 1638 and/or ANSI/UL 464 and CAN/ULC S526 and/or CAN/ULCS525. The notification appliance (WGEC) shall produce a peak sound output of 100dBA or greater at as measured in an anechoic chamber and shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/ visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 170mA or less for the 75Cd strobe circuit. The appliance shall also be capable of meeting the candela requirements of the ADA (75cd). The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models. The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. The appliance has extended temperature range of -31° to 150°F (-35° to 66° C). The appliance shall satisfy virtually all outdoor and severe environment applications. The GOE Enclosure is includes a gasket that must be inserted between the box and mounting bracket. There are drain holes in the back box to allow for drainage, the seal on the GOE Enclosure is not water tight. The GOELP Enclosure includes a weather seal for mounting to wall and intended for use with universal electrical box. To allow for drainage, bottom edge of enclosure is not water tight. Important Notice: These materials have been prepared by Gentex Corporation (“Gentex”) for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person’s activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. WGES / WGEC Series Outdoor Evacuation Signals