Loading...
HomeMy WebLinkAboutAUDIBLE SIGNALS - 23-00064 - 7N Apartments - Bldg 2 - Fire AlarmGHLF 24 VDC Series Low Frequency Audible Signal 24 VDC 520 Hz square wave audible 24 units per carton, 28 pounds per carton Applications The GHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave, temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4” metal mounting plate which incorporates the popular Super-Slide® feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate® - Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire protective systems and is warranted for three years from date of purchase. Standard Features • Nominal voltage 24 VDC • Unit Dimensions: 6-1/8" (15.55 cm) high × 5-1/2" (13.97 cm) wide × 1-5/8" (4.13 cm) deep • Super-Slide® Bracket - Ease of Supervision Testing • Checkmate® - Instant Voltage Verification • Synchronize horn with Gentex GTSM Synchronization Control Module • Prewire entire system, install mounting bracket, then install signals • Input terminals accept 12 to 18 AWG • Produces a 520Hz square wave, temporal 3 tone • Jumper selection for normal or loud dBA • Temporal 4 pattern available when used with Gentex GTSM Synchronization Module • Temporal 4 520Hz measured per ANSI/UL 2075 • Tamperproof re-entrant style grill and locking screw (optional use) • Faceplate available in red or off-white Product Listings • ANSI/UL 464 Listed • CAN/ULC S525 Listed • CSFM: 7135-0569:0148 Product Compliance • NFPA 72 • IBC/IFC/IRC • Quality Management System is certified to: ISO 9001:2008 Assembled in the USA Model Part Number Nominal Voltage (VDC) GHLFW 904-0530-002 24 GHLFR 904-0531-002 24 R = Red Faceplate, W = White Faceplate. All units are plain (no lettering). GHLF - Low Frequency Audible Signal Red Wires Black Wires Optional Loud Decibel Install Jumper Notes • Operating temperature: 32° to 120°F (0° to 49°C) • The GHLF is not listed for outdoor use • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating • This appliance is not recommended for use on coded or pulsing signaling circuits • The four pulse temporal pattern (temporal 4) can only be obtained on this product when used in conjunction with the Gentex GTSM synchronization module • See GTSM control module manual (550-0632, manual issue date (02-01-15) for synchronization module wiring diagrams. GTSM manual can be obtained at www.gentex.com/fire, or call Gentex Corporation at 1-800-436-8391 5.5” 14 cm 1-5/8” 4.2 cm 6-1/8” 15.6 cm Horn Decibel Levels: Reverberant Room (dBA)24 VDC Nominal Horn Current Ratings (mA) Horn Current Ratings Over Input Voltage Range of 16-33V (mA) Horn Mode Minimum SPL at 10ft. Per ANSI/UL 464 (NORMAL) Minimum SPL at 10ft. Per ANSI/UL 464 (LOUD) 24VDC Operating Current (NORMAL) 24VDC Operating Current (LOUD) 24VFWR Operating Current (NORMAL) 24VFWR Operating Current (LOUD) Regulated 24VDC Max. Operating Current (NORMAL) Regulated 24VDC Max. Operating Current (LOUD) Regulated 24VFWR Max. Operating Current (NORMAL) Regulated 24VFWR Max. Operating Current (LOUD) Temporal 3 520 Hz 77.8 dBA 79.8 dBA 72.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 213.5 mA Temporal 4 520 Hz*81.5 dBA 83.4 dBA 75.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA 235.2 mA * Temporal 4 520 Hz measured per ANSI/UL 2075 Fire Protection Products Group | 10985 Chicago Drive | Zeeland, MI 49464 gentex.com | Phone: 616.392.7195 | Toll-free: 800.436.8391 | Fax: 616.392.4219 GHLF-02 Important Notice: These materials have been prepared by Gentex Corporation (“Gentex”) for informational purposes only, are necessarily summary, and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws, regulations and rules and the application of such laws, regulations and rules to particular fact patterns. Each person’s activities can differently affect the obligations that exist under applicable laws, regulations or rules. Therefore, these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. GHLF 24 VDC Series Low Frequency Audible Signal Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF. The appliance shall be listed with Underwriters Laboratories (ANSI/UL) for use with fire protective signaling systems ANSI/UL 464 and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The GHLF shall be mounted on the wall or the ceiling. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. Gentex Super-Slide® Mounting Bracket Allows the installer to prewire the system, test for system supervision, remove the signal head until occupancy, switch out Gentex signals without changing mounting brackets and has locking edge connector for snap-in-place installation. Gentex Checkmate® Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. Notice: Care should be taken to not short the test probes.