Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 22-00655 - Madison Memorial Hospital - Storage ExpansionAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Madison Memorial Hospital - Storage Expansion Address : 450 E Main St Record Type : Commercial - Remodel Document Filename : 22-009-A_Madison Memorial Storage Room_Permit Set 0608.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 22-00655 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G0.00 Stamp Cody Jones : Building Open 1 Approved - Building Inspector G0.02 Free text Cody Jones : Building Open 2 Ceiling to be installed to manufactures specifications. G0.00 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector E0.00 Stamp Alex Owens : Electrical Open 10 Approved - Electrical Inspector G0.00 Stamp Don Allen : Mechanical Open 1 Approved - Mechanical Inspector G0.00 Stamp Don Allen : Mechanical Open 1 Corrections Required Commercial - Remodel Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) #.#GRID/LEVEL HEAD WALL TYPE TAG WINDOW TAG DOOR TAG ROOM NAME #####ROOM TAG WALL SECTION BUILDING SECTION KEYNOTE TAG VIEW TITLE REFERENCE TAG SECTION # SECTION # VIEW # OR LETTER SHEET # A#.## 1 SIM DETAIL OR ENLARGED PLAN CALLOUT ACCESSORY TAG SHEET # SHEET # NORTH ARROW VIEW #A#.## 1 INTERIOR ELEVATION LEVEL NAME / ELEVATION MARKER 1 View Name 1/8" = 1'-0"A101 0 2' 4' 8'GRAPHIC SCALE ###M 36" 36" 16" Extra Shelf CASEWORK TAG 1 A101 1 A1.01SHEET # VIEW # OR LETTER SHEET # ## X LEVEL 0' -0" 1 A101 BUILDING ELEVATION VIEW # OR LETTER SHEET # N XXXXXXX XXX XXXx #####.A O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP: PIVOT NORTH ARCHITECTURE 300 W MAIN STREET, SUITE 200 BOISE, ID 83702 www.pivotnorthdesign.com DRAWING INDEX: PIVOT NORTH ARCHITECTURE PROJECT #: VICINITY MAP: ABBREVIATIONS: SYMBOLS: SCOPE OF WORK: 6/ 1 0 / 2 0 2 2 1 1 : 4 3 : 0 9 A M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O COVER SHEET 22-009 AMM ChB 05/12/2022 G0.00 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 MADISON MEMORIAL HOSPITAL STORAGE ROOMS ADDITION 450 EAST MAIN STREET, REXBURG, IDAHO 05/12/2022 22-009 [LOGO][STAMP PHONE: FAX: CONTACT: E-MAIL: MOBILE: INTERNET: OWNER MADISON MEMORIAL HOSPITAL 450 E MAIN ST, OFFICE 4503 REXBURG, IDAHO 83440 208.432.2494 AMOS KINGTON N/A amos.kington@mmhnet.org 208.432.2494 madisonmemorial.org [LOGO][STAMP PHONE: FAX: CONTACT: E-MAIL: MOBILE: INTERNET: ARCHITECT PIVOT NORTH ARCHITECTURE 300 W MAIN STREET, SUITE 200 BOISE, IDAHO 83702 208.690.3108 CHRIS BRODERS N/A chris@pivotnorthdesign.com N/A www.pivotnorthdesign.com [LOGO][STAMP PHONE: FAX: CONTACT: E-MAIL: MOBILE: INTERNET: MECHANICAL ENGINEER MUSGROVE ENGINEERING, P.A. 234 S WHISPERWOOD WAY BOISE, IDAHO 83709 208.384.0585 TODD NELSON N/A toddn@musgrovepa.com 208.866.1213 www.musgrovepa.com [LOGO][STAMP PHONE: FAX: CONTACT: E-MAIL: MOBILE: INTERNET: ELECTRICAL ENGINEER MUSGROVE ENGINEERING, P.A. 234 S WHISPERWOOD WAY BOISE, IDAHO 83709 208.384.0585 Matthew Bradley N/A mattb@musgrovepa.com www.musgrovepa.com INTERNATIONAL PLUMBING CODE NATIONAL ELECTRICAL CODE ZONING ORDINANCE: INTERNATIONAL MECHANICAL CODE INTERNATIONAL FIRE CODE INTERNATIONAL ENERGY CONSERVATION CODE INTERNATIONAL BUILDING CODE ACCESSIBILITY CODE APPLICABLE CODES OTHER CRITERIA DEFERRED SUBMITTALS INTERNATIONAL EXISTING BUILDING CODE 2018 ICC/ANSI A117.1/ IBC CODE 2018 EDITION 2018 EDITION 2018 EDITION 2018 EDITION 2017 IDAHO STATE PLUMBING CODE 2017 EDITION Zoning OrdinanceREXBURG FIRE ALARM FIRE SPRINKLER GENERAL G0.00 COVER SHEET G0.02 ACCESSIBILITY, CODE COMPLIANCE, WALL TYPES, & DETAILS DEMOLITION D2.01 LEVEL 3 - DEMO COMPOSITE FLOOR PLAN D2.03 LEVEL 3 - DEMO FLOOR AND CEILING PLANS ARCHITECTURAL A2.03 LEVEL 3 - COMPOSITE FLOOR PLAN A2.13 LEVEL 3 - AREA FLOOR AND CEILING PLANS A8.00 ROOM FINISH & DOOR SCHEDULE & PLANS PROJECT LOCATION N #NUMBER OR POUND ø DIAMETER ANGLE @ AT &AND CL CENTERLINE AB ANCHOR BOLT ACP ACOUSTICAL CEILING PANEL ACT ACOUSTICAL CEILING TILE ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE ASSOC ASSOCIATED AWP ACOUSTICAL WALL PANEL AWS ACOUSTICAL WALL SYSTEM BD BOARD BFC BROOM FINISH CONCRETE BLDG BUILDING BLKG BLOCKING BM BEAM BO BOTTOM OF BOT BOTTOM BRG BEARING BSMT BASEMENT BTWN BETWEEN CAB CABINET CPT CARPET C.I.P.CAST-IN-PLACE CJ CONTROL JOINT CL CENTERLINE CLG CEILING CMU CONCRETE MASONRY UNITS CO CLEAN OUT COL COLUMN CONC CONCRETE CONST CONSTRUCT CONT CONTINUOUS CSK COUNTERSINK CMT CERAMIC MOSAIC TILE CQT CERAMIC QUARRY TILE CWB CERAMIC WALL BASE DBL DOUBLE DEPT DEPARTMENT DT DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DS DOWNSPOUT EA EACH EBT EXPANSION BASE TRIM EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATION EP EPOXY PAINT EQ EQUAL EQUIP EQUIPMENT ESTR EXPOSED STRUCTURE (NEW OR EXISTING) EIFS EXTERIOR INSULATION & FINISH SYSTEM EXIST EXISTING EXP EXPANSION EXT EXTERIOR FD FLOOR DRAIN F.D.C.FIRE DEPARTMENT CONNECTION FB FIRE BLANKET FE FIRE EXTINGUISHER FF FACTORY FINISH F.H.FIRE HYDRANT FIN FINISH FL FLOOR LINE FLR FLOOR FND FOUNDATION FOC FACE OF CHANNEL FOF FACE OF FINISH FOS FACE OF STUDS FT FEET FTG FOOTING FV FIELD VERIFY GA GAUGE GALV GALVANIZED GB GYPSUM BOARD GYP.BD.GYPSUM BOARD HAS HEAD ANCHOR STUD HCW HOLLOW CORE WOOD HM HOLLOW METAL HORIZ HORIZONTAL HT HEIGHT HW HARDWOOD ICMU INTEGRAL COLORED CONCRETE MASONRY UNITS ID INSIDE DIAMETER INSUL INSULATION INT INTERIOR INV INVERT JAN JANITOR JST JOIST JT JOINT LAB LABORATORY LAM LAMINATE LAV LAVATORY MAT MATERIAL MAX MAXIMUM MECH MECHANICAL MET METAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS ML MEASURING LINE MO MASONRY OPENING MTD MOUNTED MTG MOUNTING NA NOT APPLICABLE NB NO BASE (EXPOSED WALL OR FOUNDATION) NC NEW CONCRETE NIC NOT IN CONTRACT NM NEW MASONRY NO NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OFF OFFICE OFCI OWNER FURNISHED/ CONTRACTOR INSTALLED OFOI OWNER FURNISHED/ OWNER INSTALLED OPNG OPENING OTA OPEN TO ABOVE OTS OPEN TO STRUCTURE OVF OVERFLOW PC PAINT COLOR P.I.V. POST INDICATOR VALVE PLAST PLASTIC PLYWD PLYWOOD PR PAIR R THERMAL RESISTANCE RCP REFLECTED CEILING PLAN RD ROOF DRAIN RDL RAIN DRAIN LEADER RE:REFERENCE REFRIG REFRIGERATOR REINF REINFORCING REQ REQUIRED RF EPOXY FLOOR SYSTEM RM ROOM RO ROUGH OPENING RST RUBBER STAIR TREADS RW REDWOOD RWB RUBBER WALL BASE RWC RAIN WATER CONDUCTOR SC SEALED CONCRETE SCHED SCHEDULE SCW SOLID CORE WOOD SGWB SUSPENDED GYPSUM WALL BOARD SHT SHEET SHTG SHEATHING SIM SIMILAR SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SV SHEET VINYL T&G TONGUE AND GROOVE TEMP TEMPORARY TO TOP OF TOM TOP OF MASONRY TS TUBE STEEL TYP TYPICAL UON UNLESS OTHERWISE NOTED VAR VARIES VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE W/WITH WC WATER CLOSET WD WOOD WF WALL FABRIC WH WATER HEATER WM WALK-OFF MAT W/O WITH OUT WP WATERPROOF WRGB WATER RESISTANT GYPSUM BOARD WT WEIGHT WWF WELDED WIRE FABRIC TO PROVIDE ADDITIONAL STORAGEROOMS, IN TWO AREAS OF THE EXISTING HOSPITAL, ADD AND RECONFIGURE WALLS AND DOORS AND PROVIDE UPDATED FINISHES AND MILLWORK. M0.0 MECHANICAL COVER SHEET M1.00 LEVEL 3 - HVAC PLANS E0.00 ELECTRICAL COVER SHEET E1.00 LEVEL 3 - LIGHTING PLANS E2.00 LEVEL 3 - ELECTRICAL PLANS MECHANCIAL ELECTRICAL 001 MIN 60" M I N 60 " M I N 36 " MIN 60" MIN 12" MIN 36" MIN 12" MIN 48 " MIN 30" MIN 30 " MIN 48" MIN 36" M I N 24 " M I N 48 " X MIN 60" M I N 15 " M I N 30 "X CIRCULAR T-SHAPED FORWARD PARALLEL FORWARD APPROACH PARALLEL APPROACH MANEUVERING CLEARANCE IN AN ALCOVEPOSITION OF CELAR FLOOR OR GROUND SPACE SIZE OF WHEELCHAIR TURNING SPACE MIN9" MIN 11" M I N 27 " MIN 8" MIN9" MIN 17" KNEE CLEARANCE TOE CLEARANCE VERTICAL CHANGES IN LEVELS 1/4" MAX BEVELED CHANGES IN LEVELS 2 11/ 4 " - 1 / 2 " RECEPTACLE OUTLET UNOBSTRUCTED THERMOSTAT UNOBSTRUCTED SWITCH RECEPTACLES AND SWITCH MOUNTING HEIGHTS UNOBSTRUCTED FIRE ALARM PULL BOX 15 " M I N . 36 " M I N . 48 " M A X . 48 " M A X . CODE ANALYSIS SUMMARY USE AND OCCUPANCY CLASSIFICATION (PER IBC CHAPTER 3) GROUP(S):I-2 GENERAL BUILDING HEIGHTS AND AREAS (PER IBC CHAPTER 5) CONSTRUCTION TYPE:I-B BUILDING HEIGHT IN FEET (TABLE 504.3): BUILDING HEIGHT IN STORIES (TABLE 504.4): ALLOWABLE 160 4 TOTAL ALLOWABLE BUILDING AREA (SF):UL SF MIXED OCCUPANCIES:ACCESSORY OCCUPANCIES FIRE RESISTIVE RATING REQUIREMENTS FOR BUILDING ELEMENTS (PER IBC CHAPTER 6) CONSTRUCTION TYPE:I-B PRIMARY STRUCTURAL FRAME (HOURS):2 BEARING WALLS-EXTERIOR (HOURS): 2 BEARING WALLS-INTERIOR (HOURS):2 NONBEARING WALLS AND PARTITIONS-EXTERIOR (HOURS):0 NONBEARING WALLS AND PARTITIONS INTERIOR (HOURS):0 FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (HOURS):2 ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (HOURS):1 INTERIOR FINISHES (IBC CHAPTER 8) OCCUPANCY INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS CORRIDORS AND ENCLOSURES FOR EXIT ACCESS STAIRWAYS AND RAMPS ROOMS AND ENCLOSED SPACES GROUP I-2 B B B FIRE PROTECTION SYSTEMS (PER IBC CHAPTER 9) AUTOMATIC SPRINKLER SYSTEM:NFPA 13 MEANS OF EGRESS (PER IBC CHAPTER 10) MAXIMUM COMMON PATH OF EGRESS TRAVEL (FEET): MAXIMUM EXIT ACCESS TRAVEL DISTANCE (FEET): 75 200 WA L L T Y P E S SE E METAL STUDS MOUNTED TO DECK AT 48" O.C. INTERIOR PARTITION -SEE WALL TYPES SOUND INSULATION , WHERE OCCURS -SEE WALL TYPES CEILING SYSTEM AS SCHEDULED(CEILINGS ON OPPOSITE SIDES OF WALL MAY BE AT DIFFERENT HEIGHTS -SEE REFLECTED CEILING PLAN)STUDS. RE: FLOOR PLANS AND WALL TYPES 2X FIRE TREATED SOLID BLOCKING +/- 4 7/8" WALL FIRE RATING: FIRE TEST: WALL HEIGHT: EXTERIOR INTERIOR SOUND RATING:S31 1-HOUR UL U419 (NON-BEARING) TO DECK ABOVE 5/8" GYPSUM WALL BOARD, TYPE X STEEL STUD 5/8" GYPSUM WALL BOARD, TYPE X SOUND ATTENUATION BLANKET INSULATION 4 7/8" 1. WALL TYPES DESCRIBED ON THIS SHEET DO NOT ACCOUNT FOR REQUIRED BACKING AND/OR SUPPORT FOR WALL MOUNTED FIXTURES, EQUIPMENT, CASEWORK AND/OR SYSTEMS FURNITURE. COORDINATE WITH ENLARGED FLOOR PLANS, INTERIOR ELEVATIONS AND EQUIPMENT PLANS PRIOR TO THE COVERING OF STUD FRAMING. REFER TO MANUFACTURER'S RECOMMENDATIONS AND USE DETAIL A1/G0.02 WHERE APPLICABLE 2. PROVIDE SEISMIC BRACING PER DETAIL A2/G0.02 AT ALL WALL TYPES THAT DO NOT EXTEND TO DECK 3. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE SEALED AS PER MANUFACTURERS RECOMMENDATION AND IN ACCORDANCE W/ ASSOCIATED UL LISTING 4. WALL THICKNESS DESCRIBED ON THIS SHEET ARE SHOWN NOMINALLY IN PLAN REPRESENTATIONS 5. HORIZONTAL BRACING 2'-0" A.F.F. AT FIRST OCCURRENCE AND EVERY 4'-0" THEREAFTER AT ALL WALLS W/ GYPSUM WALL BOARD ON ONLY ONE SIDE. 6. SEE B2/G0.02 FOR PARTITION PRIORITY LEGEND FOR SEQUENCING OF RATED WALL CONSTRUCTION. 7. WHERE INTERIOR RATED WALLS MEET WITH EXTERIOR WALL SYSTEMS SEE DETAIL B3/G0.02. 8. AT ALL WALLS WITH SOUND ATTENUATION, SEAL TOP OF WALL AT STRUCTURE AND BOTTOM OF WALL WITH SOUND SEALANT 9. AT ALL WALLS THAT EXTEND TO STRUCTURE PROVIDE DEFLECTION TRACK. SEE DETAILS A3 & A4/G0.02 FOR TYPICAL CONDITION. FOR INSTANCES WHERE BEAM INTERRUPTS CONTINUATION OF WALL TO DECK ABOVE SEE DETAIL A5/G0.02. 10. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF CLEARANCES AND ADA REQUIREMENTS ARE NOT ACHIEVED. GENERAL NOTES - WALL TYPES 5/8" GYP. BD. 7/8" HAT CHANNELS @ 24" O.C. 1 1/2" COLD ROLLED STEEL CHANNEL @ 48" O.C. RIVET METAL ANGLE EDGE TO T-BAR @ 24" O.C. CEILING PANEL SLIP JOINT (NO RIVET) HEAVY-DUTY T-BAR GRID SYSTEM SCHEDULED WALL LAY-IN ACOUSTIC CEILING PANEL NOTE: PROVIDE PERIMETER SUPPORTING CLOSURE ANGLE. ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE ON TWO ADJACENT SIDES. THE OPPOSITE ENDS SHALL HAVE A 3/4" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON CLOSURE ANGLE. 7/8" 3/4" MIN 7/8" C R O S S R U N N E R2" MIN MAIN RUNNER 45 deg. MAX 45 deg. MAX 2" MIN VERTICAL HANGER WIRES 4'-0" OC SPLAY HANGER WIRE AT 12'-0" O.C. EACH PLANE, EACH RUNNER 1 5/8" STUD FOR COMPRESSION 1 2 '-0 " T Y P I C A L 1 2 ' - 0 " T Y P I C A L 4 '-0 " M A X 45 O G0.02 D1 CEILING SUSPENSION SYSTEM FIRST LINE OF BRACING 4'-0" OR LESS FROM WALL BOUNDARY NON-RATED WALL SMOKE TIGHT WALL TWO HOUR FIRE AND SMOKE WALL TWO HOUR FIRE WALL TWO HOUR SHAFT WALL ONE HOUR FIRE AND SMOKE WALL ONE HOUR FIRE WALL PRIORITY 6 PRIORITY 5 PRIORITY 3 PRIORITY 4 PRIORITY 2 PRIORITY 1 HIGHEST PARTITION PRIORITY LEGEND LOWEST PRIORITY HIGHEST PRIORITY LOWEST PRIORITY HIGHEST PRIORITY EXTERIOR SHEATHING STEEL ROOF DECKING 5/8" GYPSUM WALL BOARD, TYPE X STEEL STUD FRAMING (NON-LOAD-BEARING) ? STEEL RUNNER/TRACK M I N C L E A R 3/ 4 " MIN C L E A R 3/ 4 " 1.01 GYPSUM CEILING BOARD STEEL ROOF DECKING ACOUSTICAL JOINT SEALANT 5/8" GYPSUM WALL BOARD, TYPE X STEEL STUD FRAMING (NON-LOAD-BEARING) SOUND ATTENUATION BLANKET INSULATION 3/ 4 " M I N . C L E A R NOTE: FIRESTOP SYSTEM IS REQUIRED ONLY AT RATED WALLS. REFER TO SHEET G2.01 FOR LOCATIONS. USE APPROPRIATE UL LISTED ASSEMBLY BASED ON WALL AND STRUCTURAL DECK CONSTRUCTION. STEEL ROOF DECKING ACOUSTICAL JOINT SEALANT 5/8" GYPSUM WALL BOARD, TYPE X STEEL STUD FRAMING (NON-LOAD-BEARING) SOUND ATTENUATION BLANKET INSULATION 3/ 4 " M I N . C L E A R NOTE: FIRESTOP SYSTEM IS REQUIRED ONLY AT RATED WALLS. REFER TO SHEET G2.01 FOR LOCATIONS. USE APPROPRIATE UL LISTED ASSEMBLY BASED ON WALL AND STRUCTURAL DECK CONSTRUCTION. O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 6/ 1 0 / 2 0 2 2 1 1 : 4 3 : 1 0 A M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O ACCESSIBILITY, CODE COMPLIANCE, WALL TYPES, & DETAILS 22-009 AMM ChB 05/12/2022 G0.02 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 3/8" = 1'-0"G0.02 C3 CLEAR FLOOR SPACES 6" = 1'-0"G0.02 B1 CHANGE IN LEVELS 3/8" = 1'-0"G0.02 C1 MISC. MOUNTING HEIGHTS 12" = 1'-0"G0.02 A2 SEISMIC BRACING @ PARTITION WALLS, TYP. 1/2" = 1'-0"G0.02 A1 MOUNTING PLATE ELEVATION, TYP. 1 1/2" = 1'-0" WALL TYPES - INTERIOR 3" = 1'-0"G0.02 E2 SUSPENDED CEILING DETAIL 3" = 1'-0"G0.02 D2 TYPICAL LAY-IN CEILING TILE EDGE DETAIL 12" = 1'-0"G0.02 D1 TYPICAL SEISMIC BRACING DETAIL-01 12" = 1'-0"G0.02 E1 TYPICAL SEISMIC BRACING DETAIL-02 3" = 1'-0"G0.02 B3 PARTITION PRIORITY LEGEND 3" = 1'-0"G0.02 B2 RATED INTERIOR WALL AT EXTERIOR WALL 1 1/2" = 1'-0"G0.02 A5 FRAMING TRANSITION DETAIL 1 1/2" = 1'-0"G0.02 A3 FIRESTOPPING WALL TO DECK (PARALLEL TO FLUTES) 1 1/2" = 1'-0"G0.02 A4 FIRESTOPPING WALL TO DECK (PERPENDICULAR TO FLUTES) 002 Ceiling to be installed to manufactures specifications. 3098 VITREOU S CHIN A LAVATORYGREE N W I C H K-2030 K-4368HIGHCLIFFC_TOILETSVITREOUSCHINA K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K-4368HIG HCLIFFC_ TOILETSVITREOU SCHIN A K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINAK - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 VITR E O U S C H I N A LAVATO R Y G R E E N W I C H K - 2 0 3 0 VITREOUSCHINALAVATORYGREENWICHK-2030 VITREOUSCHINALAVATORYGREENWICHK-2030 VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS/PARTITIONS. 2. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FACE OF EXISTING FINISH. 3. SCREENED LINES REPRESENT EXISTING WALLS, DOORS, WINDOWS, ETC TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION ACTIVITIES. 4. FOR DIMENSIONAL EXTENTS OF EXISTING WALL DEMOLITION, CUTTING AND PATCHING, SEE NEW FLOOR PLANS. 5. PROTECT FROM DAMAGE ALL EXISTING TO REMAIN CASEWORK, EQUIPMENT, FLOOR FINISHES AND CEILING FINISHES DURING CONSTRUCTION. 6. PROTECT FROM DAMAGE DURING DEMOLITION, MOVING AND CONSTRUCTION ALL EXISTING CASEWORK, EQUIPMENT, FURNITURE AND ARTWORK THAT IS TO BE RE-USED. 7. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION WORK. 8. COORDINATE THE DEMOLITION OF EXISTING CEILING WITH NEW PLANS, REFLECTED CEILING PLANS AND ROOF FINISH SCHEDULE. DEMO GENERAL NOTES EXISTING WALL SYSTEM TO BE REMOVED AND ALL ASSOCIATED ITEMS TO ACCOMODATE NEW CONSTRUCTION. RELOCATE MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION. COORDINATE REMOVAL OF WALL SYSTEM, PATCH AND REPAIR WITH NEW CONSTRUCTION SCOPE OF WORK. EXISTING DOOR SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. EXISTING WALL SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. LEGEND EXISTING DOOR SYSTEM TO REMOVED AND ALL ASSOCIATED ITEMS TO ACCOMODATE NEW CONSTRUCTION. COORDINATE REMOVAL OF DOOR SYSTEM, PATCH AND REPAIR WITH NEW CONSTRUCTION SCOPE OF WORK. EXISTING WINDOW TO REMAIN EXISTING WINDOW AND FRAME TO BE REMOVED A B N KEY PLAN JAN. 3044CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 HOLDING NURSERY 3049 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 CORRIDOR 3050 CORRIDOR 3041 CORRIDOR 3037 MEDS 3036 STORAGE 3100 CORRIDOR 3099 CORRIDOR 3106 AREA B AREA A CORRIDOR 3033 D2.03 B4 D2.03 D4 PUBLIC TOILET 3102 OPEN OFFICE 3124 O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 6/ 1 0 / 2 0 2 2 1 1 : 4 3 : 0 7 A M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O LEVEL 3 -DEMO COMPOSITE FLOOR PLAN 22-009 AMM ChB 05/12/2022 D2.01 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2NNOTES - REFERENCE NOTES 3/32" = 1'-0"D2.01 E2 LEVEL 3-DEMO COMPOSITE FLOOR PLAN 003 K-6676TYRRELLC_SINKSVITREOUSCHINA K-4368HIGHCLIFFC_TOILETSVITREOUSCHINA K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA VITR E O U S C H I N A LAVATO R Y G R E E N W I C H K - 2 0 3 0 VITREOUSCHINALAVATORYGREENWICHK-2030 SANIJET 36 X 72 VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS/PARTITIONS. 2. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FACE OF EXISTING FINISH. 3. SCREENED LINES REPRESENT EXISTING WALLS, DOORS, WINDOWS, ETC TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION ACTIVITIES. 4. FOR DIMENSIONAL EXTENTS OF EXISTING WALL DEMOLITION, CUTTING AND PATCHING, SEE NEW FLOOR PLANS. 5. PROTECT FROM DAMAGE ALL EXISTING TO REMAIN CASEWORK, EQUIPMENT, FLOOR FINISHES AND CEILING FINISHES DURING CONSTRUCTION. 6. PROTECT FROM DAMAGE DURING DEMOLITION, MOVING AND CONSTRUCTION ALL EXISTING CASEWORK, EQUIPMENT, FURNITURE AND ARTWORK THAT IS TO BE RE-USED. 7. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION WORK. 8. COORDINATE THE DEMOLITION OF EXISTING CEILING WITH NEW PLANS, REFLECTED CEILING PLANS AND ROOF FINISH SCHEDULE. DEMO GENERAL NOTES EXISTING WALL SYSTEM TO BE REMOVED AND ALL ASSOCIATED ITEMS TO ACCOMODATE NEW CONSTRUCTION. RELOCATE MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION. COORDINATE REMOVAL OF WALL SYSTEM, PATCH AND REPAIR WITH NEW CONSTRUCTION SCOPE OF WORK. EXISTING DOOR SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. EXISTING WALL SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. LEGEND EXISTING DOOR SYSTEM TO REMOVED AND ALL ASSOCIATED ITEMS TO ACCOMODATE NEW CONSTRUCTION. COORDINATE REMOVAL OF DOOR SYSTEM, PATCH AND REPAIR WITH NEW CONSTRUCTION SCOPE OF WORK. EXISTING WINDOW TO REMAIN EXISTING WINDOW AND FRAME TO BE REMOVED LEGEND - CEILING DEMO EXISTING CEILING SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. REMOVE EXISTING ACOUSTICAL CEILING TILE AND ALL ASSOCIATED ITEMS. COORDINATE WITH NEW CONSTRUCTION SCOPE OF WORK. RELOCATE MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION. EXISTING GYPSUM BOARD CEILING TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. REMOVE EXISTING GYPSUM WALL BOARD CEILING AND ALL ASSOCIATED ITEMS. COORDINATE WITH NEW CONSTRUCTION SCOPE OF WORK. RELOCATE MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION. REMOVE EXISTING LIGHTING FIXTURES. COORDINATE WITH ELECTRICAL DRAWINGS. REMOVE EXISTING MECHANICAL FIXTURES. COORDINATE WITH MECHANICAL DRAWINGS. EXISTING LIGHTING FIXTURES TO REMAIN, COORDINATE WITH ELECTRICAL DRAWINGS. EXISTING MECHANICAL FIXTURES TO REMAIN, COORDINATE WITH MECHANICAL DRAWINGS. A B N KEY PLAN 2.042.03 JAN. 3044CLEAN 3040 SOILED 3045 STAFF TOILET 3046 TUB JACUZZI 3039 NOURISHMENT 3043 NURSE STATION 3035 MEDS 3036 CORRIDOR 3037 HOLDING NURSERY 3049 CORRIDOR 3050 CORRIDOR 3041 2.05 2.05 PROCEDURE 3048 JAN. 3047 2.21 2.22 2.07 CORRIDOR 3106 CORRIDOR 3099 LIGHT WELL 3098 OPEN OFFICE 3124 PUBLIC TOILET 3102 WAITING 3100 2.07 JAN. 3044CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 TUB JACUZZI 3039 JAN. 3047 NOURISHMENT 3043 NURSE STATION 3035 MEDS 3036 CORRIDOR 3037 HOLDING NURSERY 3049 CORRIDOR 3050 CORRIDOR 3041 9' - 0" A.F.F. 8' - 0" A.F.F. 8' - 0" A.F.F.8' - 6" A.F.F. 7' - 0" A.F.F. 7' - 0" A.F.F. 9' - 0" A.F.F. 8' - 0" A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F. 8' - 0" A.F.F. 7' - 10" A.F.F. 8' - 0" A.F.F.9' - 0" A.F.F. 2.12 2.20 7' - 0" A.F.F. CORRIDOR 3106 CORRIDOR 3099 LIGHT WELL 3098 OPEN OFFICE 3124 PUBLIC TOILET 3102 8' - 0" A.F.F. 9' - 0" A.F.F. 7' - 10" A.F.F.7' - 10" A.F.F. 8' - 0" A.F.F.9' - 0" A.F.F. 8' - 0" A.F.F. 7' - 10" A.F.F. 2.12 WAITING 3100 O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 6/ 1 0 / 2 0 2 2 1 1 : 4 3 : 0 9 A M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O LEVEL 3 -DEMO FLOOR AND CEILING PLANS 22-009 AMM ChB 05/12/2022 D2.03 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 NOTES - REFERENCE NOTES 2.03 REMOVE EXISTING WALL SYSTEM AND ALL ASSOCIATED ITEMS. COORDINATE PATCH AND REPAIR WORK WITH NEW CONSTRUCTION SCOPE OF WORK. 2.04 REMOVE EXISTING DOOR, FRAME AND ALL ASSOCIATED ITEMS. COORDINATE WITH OWNER FOR STORAGE OF DOOR. COORDINATE WITH NEW CONSTRUCTION SCOPE OF WORK. 2.05 REMOVE EXISTING CASEWORK, PLUMBING AND ALL ASSOCIATED ITEMS. COORDINATE WITH MECHANICAL DRAWINGS AND NEW CONSTRUCTION SCOPE OF WORK FOR CAPPING/ABANDONING LINES AND RELOCATED SINKS. 2.07 REMOVE EXISTING FLOORING, PATCH AND REPAIR SUBSTRATE TO RECIEVE NEW FLOORING. COORDINATE WITH NEW CONSTRUCTION SCOPE OF WORK. 2.12 REMOVE EXISTING CEILING SYSTEM AND ALL ASSOCIATED ITEMS. RELOCATE MECHANICAL AND ELECTRICAL ITESM AS REQUIRED. COORDINATE REMOVAL OF CEILING, PATCH AND REPAIR WITH NEW CONSTRUCTION SCOPE OF WORK. 2.20 REMOVE HEADER TO A HEIGHT OF 7' - 0" A.F.F. 2.21 REMOVE CEILING CURTAIN AND TRACK. COORDINATE WITH OWNER FOR STORAGE. 2.22 EXISTING EQUIPMENT TO BE REMOVED BY OWNER. 1/4" = 1'-0"D2.03 B4 LEVEL 3-AREA A DEMO FLOOR PLAN 1/4" = 1'-0"D2.03 D4 LEVEL 3-AREA B DEMO FLOOR PLAN 1/4" = 1'-0"D2.03 B1 LEVEL 3-AREA A DEMO CEILING PLAN 1/4" = 1'-0"D2.03 D1 LEVEL 3-AREA B DEMO CEILING PLAN N N N N 004 3098 VITREOU S CHIN A LAVATORYGREE N W I C H K-2030 K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K-4368HIG HCLIFFC_ TOILETSVITREOU SCHIN A K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINAK - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 VITR E O U S C H I N A LAVATO R Y G R E E N W I C H K - 2 0 3 0 VITREOUSCHINALAVATORYGREENWICHK-2030 VITREOUSCHINALAVATORYGREENWICHK-2030 VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS / PARTITIONS. 2. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO FACE OF FINISHED MASONRY FOR CMU. 3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FACE OF EXISTING FINISH. 4. FOR FLOOR FINISHES RE: ROOM FINISH SCHEDULE AND PLANS, SHEET A8.00. 5. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 4" STUD FRAME RETURN AT ALL DOOR AND WINDOW JAMBS. 6. SEE ENLARGED PLANS FOR ADDITIONAL WALL TYPES. 7. FOR WALLS NOT DESIGNATED WITH A WALL TYPE, COORDINATE WITH ARCHITECT, STRUCTURAL DRAWINGS, AND EXISTING CONDITIONS. 8. UNLESS NOTED OTHERWISE, RE: G0.03 FOR TYPICAL MANEUVERING CLEARANCE REQUIREMENTS FOR ALL DOORS. 9. RE: SHEET G0.02 FOR BUILDING OCCUPANCY PLANS AND FIRE RESISTIVE CONSTRUCTION REQUIREMENTS. GENERAL NOTES A B N KEY PLAN JAN. 3044CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 HOLDING NURSERY 3049 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 CORRIDOR 3050 CORRIDOR 3041 CORRIDOR 3037 MEDS 3036 STORAGE 3100 CORRIDOR 3099 CORRIDOR 3106AREA B AREA A A2.13 B4 A2.13 D4 CORRIDOR 3033 PUBLIC TOILET 3102 OPEN OFFICE 3124 O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 6/ 1 0 / 2 0 2 2 1 1 : 4 3 : 0 2 A M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O LEVEL 3 - COMPOSITE FLOOR PLAN 22-009 AMM ChB 05/12/2022 A2.03 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 3/32" = 1'-0"A2.03 E2 LEVEL 3-COMPOSITE FLOOR PLAN N 005 K-6676TYRRELLC_SINKSVITREOUSCHINA K-4368HIGHCLIFFC_TOILETSVITREOUSCHINA K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA VITR E O U S C H I N A LAVATO R Y G R E E N W I C H K - 2 0 3 0 VITREOUSCHINALAVATORYGREENWICHK-2030 SANIJET 36 X 72 VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS / PARTITIONS. 2. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO FACE OF FINISHED MASONRY FOR CMU. 3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO EXISTING CONSTRUCTION ARE TO FACE OF EXISTING FINISH. 4. FOR FLOOR FINISHES RE: ROOM FINISH SCHEDULE AND PLANS, SHEET A8.00. 5. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 4" STUD FRAME RETURN AT ALL DOOR AND WINDOW JAMBS. 6. SEE ENLARGED PLANS FOR ADDITIONAL WALL TYPES. 7. FOR WALLS NOT DESIGNATED WITH A WALL TYPE, COORDINATE WITH ARCHITECT, STRUCTURAL DRAWINGS, AND EXISTING CONDITIONS. 8. UNLESS NOTED OTHERWISE, RE: G0.03 FOR TYPICAL MANEUVERING CLEARANCE REQUIREMENTS FOR ALL DOORS. 9. RE: SHEET G0.02 FOR BUILDING OCCUPANCY PLANS AND FIRE RESISTIVE CONSTRUCTION REQUIREMENTS. GENERAL NOTES STEEL STUD WALL AND GYPSUM WALL BOARD WALL. RE: WALL TYPES. FLOOR DRAIN. COORDINATE WITH PLUMBING DRAWINGS. FIRE EXTINGUISHER CABINET. RE: SHEET G0.02 WINDOW TYPE, RE: WINDOW FRAME TYPE SHEETS, SHEET A7.01 WALL TYPE, RE: SHEET G0.02 DOOR SYMBOL, RE: DOOR SCHEDULE, SHEET A7.01 LEGEND XXXx XXXXXXX XXX FD A B N KEY PLAN 1. RE: ROOM FINISH SCHEDULE AND FINISH FLOOR PLANS FOR MATERIAL AND FINISH INFORMATION. 2. RE: BUILDING INFORMATION SHEETS FOR CODE AND FIRE INFORMATION. 3. RE: FLOOR PLANS AND DOOR SCHEDULE FOR DOOR AND FRAME TYPES. 4. PROVIDE RWB AT ALL TOE SPACES OF ALL CABINETS, SIDES OF CABINETS AND ALL KNEE SPACES BELOW CABINETS. RE: DIVISION 9, SECTION "RESILIENT BASE AND ACCESSORIES". 5. PROVIDE BLOCKING FOR ALL WALL-MOUNTED ACCESSORIES AND EQUIPMENT. GENERAL NOTES - INETERIOR ELEVATIONS JAN. 3044CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 MEDS 3036 CORRIDOR 3037 HOLDING NURSERY 3049 CORRIDOR 3050 CORRIDOR 3041 CLEAR 3' - 6" 1' - 9 3/4" 4" S36S S36S 3048 12.01 STORAGE 3100 CORRIDOR 3106 CORRIDOR 3099 LIGHT WELL 3098 OPEN OFFICE 3124 1.06 CLEAR 5' - 2" 2' - 0 " PUBLIC TOILET 3102 A2.13 E4 S3 6 S S3 6 S S36S 6' - 0 " 3100 1.06 CARD READER, RE: ELECTRICAL DRAWINGS. A2.13 E6 4' - 6 " 300 30" 30" 13" (2) HOLDING NURSERY 3049 STAFF TOILET 3046 NOURISHMENT 3043 CORRIDOR 3041 CORRIDOR 3050 SOILED 3045 JAN. 3044 JAN. 3047 CLEAN 3040 TUB JACUZZI 3039 STORAGE 3048 MEDS 3036 CORRIDOR 3037 NURSE STATION 3035 CORRIDOR 3033 9' - 0" A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F.8' - 0" A.F.F. 7' - 10" A.F.F. 8' - 0" A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F. 8' - 0" A.F.F. 8' - 6" A.F.F. 8' - 0" A.F.F. 7' - 0" A.F.F. 7' - 0" A.F.F. 7' - 0" A.F.F. 7' - 10" A.F.F. 9' - 0" A.F.F. 9' - 0" A.F.F. 8' - 0" A.F.F. 8' - 0" A.F.F. CORRIDOR 3099 PUBLIC TOILET 3102 OPEN OFFICE 3124 CORRIDOR 3106 STORAGE 3100 9.06 9.06 8' - 0" A.F.F.9' - 0" A.F.F. O.T.S. X' -X" LEGEND 2' x 4' ACOUSTICAL CEILING METAL SUSPENSION SYSTEM WITH ACOUSTICAL PANEL CEILING UNITS, APC-1, U.O.N. RE: 8.00 FINISH SCHEDULE. GYPSUM BOARD CEILING ON STEEL FRAMING AND SUPPORT SYSTEM. PAINT -P-_____, U.O.N. RE: 8.00 FINISH SCHEDULE. OPEN TO STRUCTURE VERTICAL SERVICE DROP/CHASE. COORDINATE WITH MECHANICAL DRAWINGS. LIGHTING FIXTURES, COORDINATE WITH ELECTRICAL DRAWINGS. MECHANICAL FIXTURES, COORDINATE WITH MECHANICAL DRAWINGS. CEILING HEIGHT ABOVE FINISH FLOOR EXISTING LIGHTING FIXTURES TO REMAIN, COORDINATE WITH ELECTRICAL DRAWINGS. EXISTING MECHANICAL FIXTURES TO REMAIN, COORDINATE WITH MECHANICAL DRAWINGS. EXISTING ACOUSTICAL CEILING SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. EXISTING GYPSUM BOARD CEILING TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. PAINT -P-_____, U.O.N. RE: 8.00 FINISH SCHEDULE. 1. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL ITEMS TO BE PROVIDED AT THE CEILING PLANE AND IN THE WORK. 2. CENTER ALL LIGHT FIXTURES AND SPRINKLER HEADS IN THEIR RESPECTIVE CEILING PANEL. 3. INSTALL ALL SUSPENSION SYSTEMS FOR ACOUSTICAL PANEL CEILINGS PER PROVISIONS OF ASTM C 635 AND ASTM C 636. 4. ALL SOFFIT DIMENSIONS SHOWN ARE TO FACE OF FINISH. 5. COORDINATE WITH MECHANICAL & ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR PHYSICAL SIZES OF ALL CEILING GRILLES, DIFFUSERS, FIXTURES, CANS, AND ALL RELATED ITEMS. 6. PAINT ALL EXPOSED-TO-VIEW STRUCTURAL STEEL DECK, AND ASSOCIATED STRUCTURAL ITEMS PAINT COLOR P-#____, UNLESS OTHERWISE NOTED. RE: SHEET A8.00. 7. PAINT ALL EXPOSED-TO-VIEW MECHANICAL DUCTWORK AND ASSOCIATED ITEMS, ELECTRICAL CONDUIT AND ASSOCIATED ITEMS, PLUMBING AND FIRE PROTECTION LINES AND ALL ASSOCIATED ITEMS PAINT COLOR P-#____, UNLESS OTHERWISE NOTED. RE: SHEET A8.00. 8. SUSPENSION SYSTEMS FOR GYPSUM BOARD CEILINGS SHALL BE INSTALLED PER ASTM C754. GENERAL NOTES -CEILINGS 300 30" 30" 13" 300 18" 30" 13" 4' - 6 " 6.02 O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 6/ 1 0 / 2 0 2 2 1 1 : 4 3 : 0 4 A M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O LEVEL 3 -AREA FLOOR AND CEILING PLANS 22-009 AMM ChB 05/12/2022 A2.13 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 NOTES - REFERENCE NOTES 1.06 NEW WALL PLANE TO ALIGN WITH EXISTING WALL PLANE, THERE SHALL BE NO NOTICEABLE SEAMS OR BREAKS IN FINISHED APPEARANCE OF THE WALL. 6.02 PROVIDE FILLER PANEL TO MATCH ADJACENT MILLWORK. 9.06 NEW ACT TO MATCH EXITING. 12.01 PROVIDE ADJUSTABLE SHELVING SYSTEM FOR DEPTH OF ALCOVE WITH MIN. 3 SHELVES. COORDINATE TYPE AND FINISHES WITH OWNER. 1/4" = 1'-0"A2.13 B4 LEVEL 3 - AREA A FLOOR PLAN 1/4" = 1'-0"A2.13 D4 LEVEL 3 - AREA B FLOOR PLAN N N N N 1/4" = 1'-0"A2.13 E4 EAST STORAGE ELEVATION 1/4" = 1'-0"A2.13 B1 LEVEL 3-AREA A CEILING PLAN 1/4" = 1'-0"A2.13 D1 LEVEL 3-AREA B CEILING PLAN 1/4" = 1'-0"A2.13 E6 SOUTHEAST STORAGE ELEVATION 006 K-4368HIGHCLIFFC_TOILETSVITREOUSCHINA K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA VITREOUSCHINALAVATORYGREENWICHK-2030 VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 FLOOR FINISHES ABBREVIATIONS CPT CARPET TILE CT CERAMIC TILE LN LINOLEUM LVP LUXURY VINYL PLANK LVT LUXURY VINYL TILE MCB METAL COVE BASE PC POLISHED CONCRETE QT QUARRY TILE QVT QUARTZ VINYL TILE RF RUBBER FLOOR TILE WALL BASE CT CERAMIC TILE QTB QUARRY TILE BASE RB RESILIENT BASE TZB TERRAZZO BASE WDB WOOD BASE WALL FINISHES CT CERAMIC TILE GT GLASS TILE FRP PLASTIC SHEET PANELING P PAINT RP RESIN PANEL RMA RESILIENT MOLDING ACCESSORY WC VINYL WALL COVERING WDP WOOD PANELING WP WRAPPED FABRIC PANEL CEILINGS APC ACOUSTICAL PANEL CEILING WD WOOD CEILING GBD GYPSUM BOARD CASEWORK PL PLASTIC LAMINATE SDS SOLID SURFACE TF TRANSPARENT FINISH WDP WOOD PANELING RFA RESILIENT FLOOR ACCESSORY RSA RESILENT STAIR ACCESSORY RSV RIGID SHEET VINYL RT RESILIENT TILE SD STATIC DISSIPATIVE FLOOR TILE SV VINYL SHEET FLOOR COVERING T TILE TT TILE TRIM TZ TERRAZZO WCV WINDOW COVERING WM WALK OFF MAT LVP-1 RT-1 LEGEND -FLOOR FINISHES SV-1 1. PATCH AND REPAIR ALL EXISTING FLOOR SUBSTRATES AS REQUIRED TO RECIEVE NEW FLOOR FINISHES. 2. RE: ROOM FINISH SCHEDULE SHEET FOR ADDITIONAL INFORMATION ON FLOOR AND WALL FINISHES. 3. TILE PATTERNS MUST MAINTAIN EXACT CONFIGURATION SHOWN. 4. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 5. RE: REFLECTED CEILING PLANS FOR CEILING AND SOFFIT PAINT COLOR LOCATIONS. 6. ALL TILE PATTERNS ARE TO BE FULL TILES EXCEPT WHERE PATTERN IS INTERRUPTED BY PROTIONS OF BUILDING. SEE INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. 7. FOR RUBBER WALL BASE JOB FORM INSIDE AND OUTSIDE CORNERS. 8. PROVIDE ADA COMPLIANT FLOOR ACCESSORIES FOR FLOORING TRANSITIONS. 9. NOT ALL FLOOR FINISHES ARE SHOWN ON FLOOR FINISH PLANS. RE: ROOM FINISH SCHEDULE FOR ALL FLOOR FINISH LOCATIONS. 10. ALL DOOR AND WINDOW TRIM TO BE PAINT COLOR P-# UNLESS OTHERWISE NOTED ON DOOR SCHEDULE. GENERAL NOTES A B N KEY PLAN PAINT COLOR P-# RE: FINISH LEGEND. LEGEND -WALL FINISHES P# JAN. 3044CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 MEDS 3036 CORRIDOR 3037 HOLDING NURSERY 3049 CORRIDOR 3050 CORRIDOR 3041 SV-1 1.10 1.09 STORAGE 3100 CORRIDOR 3106 CORRIDOR 3099 LIGHT WELL 3098 1.10 1.10 SV-1 1.09 1.09 F RE : D O O R S C H E D U L E AS S C H E D U L E D RE: DOOR SCHEDULE AS SCHEDULED AS S C H E D U L E D 2" 2"AS SCHEDULED2" S1 E5 A8.00 E5 A8.00 SOUND ATTENUATION BLANKET INSULATION. RE: FLOOR PLANS AND WALL TYPES. GYPSUM WALL BOARD TYPE 'X' STEEL STUD FRAMING. RE: FLOOR PLANS AND WALL TYPES. JOINT SEALANT GYPSUM WALL BOARD TYPE 'X' JOINT SEALANT HOLLOW METAL FRAME. RE: FLOOR PLANS, DOOR SCHEDULE AND DOOR AND FRAME TYPES. HOLLOW METAL DOOR. RE: FLOOR PLANS, DOOR SCHEDULE AND DOOR AND FRAME TYPES.FRAME BEYOND HATCH IN FRAME UNITS INDICATES AREAS OF FULLY-TEMPERED FLOAT GLASS. LEGEND -DOORS & FRAMES NO HATCH AREA IN FRAME UNITS INDICATES AREAS OF FLOAT GLASS. 1. PAINT ALL METAL FRAMES & ACCESSORIES PS-3_____. RE: SHEET A8.00 FINISH SCHEDULE AND LEGEND. 2. ALL HOLLOW METAL FRAME GLAZING STOPS TO BE PLACED ON ROOM SIDE OPPOSITE FROM HALLWAY / CORRIDOR. 3. PROVIDE FULLY TEMPERED GLASS UNITS WHERE REQUIRED BY I.B.C. SECTION 2406. 4. PROVIDE FLOAT GLASS AT CONDITIONS OTHER THAN DESCRIBED IN GENERAL NOTES AND DRAWING SHEET A8.00. 5. COORDINATE ALL INDICATED FRAME DETAILS WITH ACTUAL WALL CONFIGURATION. APPLY DETAILS AS APPLICABLE. GENERAL NOTES -DOORS & FRAMES ALUM -ALUMINUM FF -FACTORY FINISH AS SPECIFIED HM -HOLLOW METAL HPC -HIGH PERFORMANCE COATING M -MINUTES P#-PAINT COLOR "NUMBER" (RE: A8.00 FINISH LEGEND) WD -WOOD S -SMOKE AN -ANODIZED ABBREVIATIONS -DOORS & FRAMES O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 6/ 1 0 / 2 0 2 2 1 1 : 4 3 : 0 6 A M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O ROOM FINISH & DOOR SCHEDULE & PLANS 22-009 AMM ChB 05/12/2022 A8.00 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 SCHEDULE - ROOM FINISH Level ROOM NO. ROOM TITLE FLOOR WALLS CASEWORK REMARKSMAT. BASE NORTH EAST SOUTH WEST CABINETRY COUNTER TOP TRANS TOP LEVEL 3 3047 JAN.TBD TBD P-1 P-1 P-1 P-1 LEVEL 3 3048 STORAGE TBD TBD P-1 P-1 P-1 P-1 LEVEL 3 3100 STORAGE TBD TBD P-1 P-1 P-1 P-1 MATCH EXISTING SCHEDULE - FINISH LEGEND FINISH PRODUCT DESCRIPTION MANUFACTURER PRODUCT NUMBER COLOR COMMENTS ACT-1 CEILING TILE MATCH EXISTING - WHITE ACT-GRID CEILING GRID MATCH EXISTING - WHITE LVP-1 HARD SURFACE LUXURY VINYL PLANK SHAW CONTRACT UNCOMMON GROUND 6 0188V SKYLINE COLOR 0256 P-1 PAINT SHERWIN WILLIAMS DIVINE WHITE SW6105 RT-1 HARD SURFACE RESILIENT TILE MOHAWK GROUP SELECT STEP STONE SEA SALT T002M 18X36 SV-1 HOMOGENEOUS SHEET VINYL SHAW CONTRACT VITALITY 0873V UPLIFT 73120 USE MATCHING HEAT WELD BETWEEN SEAMS. NOTES - REFERENCE NOTES 1.09 PATCH AND REPAIR FLOORING AS NEEDED FOR NEW CONSTRUCTION. 1.10 PAINT WALLS TO MATCH ADJACENT.N N 1/4" = 1'-0"A8.00 B4 LEVEL 3 - AREA A FINISH FLOOR PLAN 1/4" = 1'-0"A8.00 D4 LEVEL 3 - AREA B FINISH FLOOR PLAN 1/2" = 1'-0" DOOR TYPES 1/2" = 1'-0" STEEL FRAME TYPES 3" = 1'-0"A8.00 E5 TYP HEAD DETAIL (JAMB SIM) (HM FRAME/STEEL STUD WALL) SCHEDULE - DOOR DOOR # DOOR FRAME DOOR HARDWARE REMARKSTYPE WIDTH HEIGHT MATERIAL FINISH TYPE MATERIAL FINISH 3048 F 3' - 0" 7' - 0" WOOD MATCH EXISTING S1 HM P-1 01 3100 F 3' - 0" 7' - 0" WOOD MATCH EXISTING S1 HM P-1 02 CARD READER RE: ELECTRICAL DOOR HARDWARE GROUPS 007 M AIRFLOW AIRFLOW S T FCO H WCO S GCO CO2 CO NO SD -- # AW AV SD D-X CFM X"Ø RD R-X X"Ø OD R-X CFM X"Ø CD G-X CFM X"Ø TW TS MPG FS G F GWS GWR CWS CWR CS CR HWS HWR L S MECHANICAL ABBREVIATIONS A/C or AC AIR CONDITIONING KW KILOWATT AFF ABOVE FINISHED FLOOR KWH KILOWATT HOUR AHU AIR HANDLING UNIT ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS LAT LEAVING AIR TEMPERATURE LAV LAVATORY BTU BRITISH THERMAL UNITS LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN BTUH BTUS PER HOUR LWT LEAVING WATER TEMPERATURE CA COMBUSTION AIR MAX MAXIMUM CC COOLING COIL MCA MINIMUM CIRCUIT AMPS CFM AIR FLOW RATE (CUBIC FEET PER MINUTE)MOCP MAXIMUM OVERCURRENT PROTECTION CHWR CHILLED WATER RETURN MIN MINIMUM CHWS CHILLED WATER SUPPLY CLG CEILING NC NOISE CRITERIA CW COLD WATER NFPA NATIONAL FIRE PROTECTION ASSOCIATION NTS NOT TO SCALE DEG or ° DEGREE DIA or Ø DIAMETER OSA OUTSIDE AIR DB DRY BULB PD PRESSURE DROP EA EXHAUST AIR PH or Ø PHASE EAT ENTERING AIR TEMPERATURE PRV PRESSURE REDUCING VALVE EER ENERGY EFFICIENCY RATIO ESP EXTERNAL STATIC PRESSURE RA RETURN AIR EWT ENTERING WATER TEMPERATURE RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT FCO FLOOR CLEANOUT FD FIRE DAMPER SA SUPPLY AIR FLA FULL LOAD AMPS SEER SEASONAL ENERGY EFFICIENCY RATIO FLR FLOOR SFD COMBINATION SMOKE/FIRE DAMPER FPM FEET PER MINUTE SP STATIC PRESSURE FT FEET SYM SYMBOL GA GAUGE T & P TEMPERATURE AND PRESSURE GCO GRADE CLEANOUT TEMP TEMPERATURE GPM WATER FLOW RATE (GALLONS PER MINUTE) TYP TYPICAL HC HEATING COIL UMC UNIFORM MECHANICAL CODE HP HORSE POWER UPC UNIFORM PLUMBING CODE HVAC HEATING, VENTILATING, AIR CONDITIONING URL URINAL HW HOT WATER HWR HOT WATER RETURN VTR VENT THROUGH ROOF HWS HOT WATER SUPPLY V VOLTS IBC INTERNATIONAL BUILDING CODE W/ WITH IEEC INTERNATIONAL ENERGY CONSERVATION CODE WB WET-BULB IFC INTERNATIONAL FIRE CODE WC WATER CLOSET IFGC INTERNATIONAL FUEL GAS CODE WCO WALL CLEANOUT IMC INTERNATIONAL MECHANICAL CODE WH WATER HEATER IPC INTERNATIONAL PLUMBING CODE NOTE:THIS IS A STANDARD LIST OF COMMONLY USED MECHANICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. MECHANICAL AND PLUMBING DRAWINGS LEGEND FLEXIBLE DUCTWORK THREE WAY CONTROL VALVE DUCTWORK TWO WAY CONTROL VALVE DUCTWORK BREAK PRESSURE REDUCING VALVE DUCTWORK OR PIPING RISE GATE VALVE CONCENTRIC SQUARE TO ROUND TRANSITION REDUCER MOTORIZED DAMPER GLOBE VALVE MANUAL VOLUME DAMPER BALL VALVE SPIN-IN FITTING W/ AIR EXTRACTOR AND HAND DAMPER BUTTERFLY VALVE HIGH EFFICIENCY FITTING W/ HAND DAMPER BALANCE VALVE SWITCH CHECK VALVE THERMOSTAT FLOOR CLEANOUT HUMIDISTAT WALL CLEANOUT TEMPERATURE SENSOR GRADE CLEANOUT CARBON DIOXIDE SENSOR WATER HAMMER ARRESTOR CARBON MONOXIDE SENSOR FLOOR DRAIN NITROUS OXIDE SENSOR FLOOR SINK DUCT SMOKE DETECTOR GAS PRESSURE REGULATOR W/ GAS COCK COMBINATION SMOKE/FIRE DAMPER PRESSURE RELIEF VALVE FIRE DAMPER VENT-THROUGH-ROOF SMOKE DAMPER VENT EQUIPMENT CALLOUT SOIL, WASTE, OR SANITARY SEWER TURNING VANES ACID WASTE LINE INTAKE OR EXHAUST ACID VENT LINE DIRECTION OF AIRFLOW STORM DRAIN SUPPLY DIFFUSER ROOF DRAIN LINE RETURN GRILLE OVERFLOW DRAIN LINE EXHAUST GRILLE CONDENSATE DRAIN LINE FLOOR GRILLE DOMESTIC COLD WATER (CW) CEILING EXHAUST FAN DOMESTIC HOT WATER (HW) TEMPERATURE GAUGE DOMESTIC HOT WATER RETURN (HWR) PRESSURE GAUGE (LIQUID FILLED W/ ISOLATION VALVE)TEMPERED WATER (TW) TEMPERATURE SENSOR (DUCT OR PIPING) MEDIUM PRESSURE NATURAL GAS FLOW SWITCH LOW PRESSURE NATURAL GAS STAINLESS STEEL BRAIDED FLEX CONNECTION FIRE SPRINKLER LINE ELASTOMETRIC FLEX CONNECTOR GEOTHERMAL WATER SUPPLY SUCTION DIFFUSER GEOTHERMAL WATER RETURN Y TYPE STRAINER (1-1/2" OR LARGER PROVIDED W/ BLOW DOWN VALVE)CHILLED WATER SUPPLY FLOW DIRECTION CHILLED WATER RETURN DEMOLITION / EQUIPMENT TO BE REMOVED CONDENSER WATER SUPPLY NEW TO EXISTING CONNECTION POINT CONDENSER WATER RETURN (E)EXISTING HEATING WATER SUPPLY (F)FUTURE HEATING WATER RETURN (N)NEW LIQUID REFRIGERANT LINE REDUCED PRESSURE BACKFLOW PREVENTER SUCTION REFRIGERANT LINE DOUBLE CHECK BACKFLOW PREVENTER SLOPE PIPE IN DIRECTION OF ARROW UNION PIPE ANCHOR AIR VENT PIPE GUIDE TRIPLE DUTY VALVE CAP NOTE:THIS IS A LIST OF COMMONLY USED MECHANICAL AND PLUMBING SYMBOLS. SOME OF THE SYMBOLS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. MECHANICAL GENERAL NOTES 1. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE (IMC) LATEST EDITION, AND ALL APPLICABLE LOCAL AND STATE CODES. 2. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED PLUMBING CODE, AND ALL LOCAL AND STATE CODES. 3. ALL MECHANICAL AND PLUMBING EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS. 4. MECHANICAL CONTRACTORS SHALL RECEIVE PRIOR APPROVAL FROM THE STRUCTURAL ENGINEER BEFORE MAKING CUTS THROUGH ANY STRUCTURAL MEMBER. 5. MECHANICAL CONTRACTORS SHALL COORDINATE INSTALLATION WITH CONSTRUCTION SUPERVISOR AND WITH ALL OTHER TRADES TO AVOID CONFLICTS. 6. THE MECHANICAL CONTRACTORS SHALL VERIFY MOTOR VOLTAGES WITH THE ELECTRICAL DRAWINGS PRIOR TO ORDERING MOTORIZED EQUIPMENT AND CONTROLS. 7. SEE MECHANICAL SCHEDULE SHEET FOR SCHEDULED CAPACITIES OF ALL MECHANICAL EQUIPMENT AND MATERIALS SPECIFIED. 8. DOMESTIC WATER SERVICE IS PROVIDED WITH A DOUBLE-CHECK BACKFLOW PREVENTER ASSEMBLY. 9. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL BACKFLOW DEVICES TO INSPECTED BY A CERTIFIED BACKFLOW TECHNICIAN BEFORE THE USE OF THE BUILDING POTABLE WATER SYSTEM. 10. ALL MECHANICAL EQUIPMENT TO BE PROPOSED MUST BE ON THE APPROVED LIST PRIOR TO SUBMITTALS. ALL APPROVED MANUFACTURERS MUST BE CAPABLE OF MEETING THE REQUIREMENTS OF THE SPECIFIED EQUIPMENT. 11. RUNOUT AND HOOKUP SIZES TO INDIVIDUAL PLUMBING FIXTURES CAN BE FOUND ON THE PLUMBING FIXTURE SCHEDULE. 12. PROVIDE REMOTE CEILING ACCESS BALANCE DAMPERS WITH CONCEALED CHROME PLATE COVERS FOR BALANCE DAMPERS LOCATED ABOVE HARD CEILINGS. 13. PAINT VTR'S, FLUES, EXHAUST CAPS, AND OTHER MECHANICAL ITEMS ON THE ROOF TO MATCH THE ROOF COLOR. 14. INSULATED FLEXIBLE DUCTWORK--IN LENGTHS OF 6'-0" OR LESS--MAY BE USED FOR RUNOUTS TO AIR TERMINALS. 15. MAINTAIN MINIMUM 10'-0" DISTANCE BETWEEN ALL FRESH AIR INTAKES AND EXHAUST OR GAS FLUE DISCHARGES. 16. LOCATE ACCESS HATCHCES SO AS TO PROVIDE OPTIMUM SERVICEABILITY TO EQUIPMENT AND/OR VALVING. SEE ARCHITECTURAL SPECIFICATION FOR TYPE AND COLOR. COORDINATE LOCATION WITH ARCHITECTURAL, STRUCTURAL, AND LIGHTING. 17. WHENEVER THERE IS A DISCREPANCY BETWEEN THE RUNOUT DUCT SIZE SHOWN ON THE PLANS AND THAT SHOWN IN THE SCHEDULE, ALWAYS USE THE LARGER OF THE TWO DUCT SIZES. 18. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VERIFICATION OF EXISTING JOB CONDITIONS PRIOR TO BID. NO ADDITIONAL COST SHALL BE AWARDED TO THE SUCCESSFUL CONTRACTOR (OR THEIR SUBCONTRACTORS) AFTER BIDS HAVE BEEN SUBMITTED AND CONTRACTS AWARDED FOR FAILURE TO VERIFY EXISTING FIELD CONDITIONS. DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR ALTERNATIVE METHODS OF INSTALLATION PRIOR TO THE BIDDING OF THIS PROJECT. 19. UNLESS OTHERWISE NOTED, ALL EXISTING MECHANICAL EQUIPMENT, PIPING, ETC, TO BE REMOVED SHALL BE DISPOSED OF BY THE CONTRACTOR UNDER THIS CONTRACT. THE OWNER SHALL RETAIN THE RIGHT TO KEEP ANY REMOVED ITEMS. 20. ALL DOMESTIC HOT AND COLD WATER LINES IN THE AREA OF WORK WHICH ARE NO LONGER IN USE DUE TO THIS PROJECT SHALL BE REMOVED BACK TO THE MAINS AND CAPPED. NO DEAD LEGS ALLOWED. 21. HOLES IN EXISTING WALLS OR FLOORS SHALL BE PATCHED TO MATCH EXISTING WHERE PIPING, DUCTWORK, ETC, WERE REMOVED OR ADDED DURING THIS PROJECT. 22. DAMAGE TO THE EXISTING FACILITY DURING THE CONSTRUCTION OF THIS PROJECT SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO COST THE OWNER. P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E PROJECT NO. - 22-194 6/ 8 / 2 0 2 2 1 2 : 5 2 : 1 9 P M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O MECHANICAL COVER SHEET 22-009 Author Checker 06/08/2022 M0.0 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 06/08/2022 008 K - 6 6 7 6 T Y R R E L L C _ S I N K S V I T R E O U S C H I N A K - 4 3 6 8 H I G H C L I F F C _ T O I L E T S V I T R E O U S C H I N A K - 4368H IGH CLIFFC _ TOILETSVITR EOU SC HINA VITR E O U S C H I N A LAVATO R Y G R E E N W I C H K - 2 0 3 0 VITR E O U S C H I N A LAVATO R Y G R E E N W I C H K - 2 0 3 0 SANIJET 36 X 72 VITR EOU SC HINALAVATO R YG REENW ICHK - 2030 JAN. 3044 CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 HOLDING NURSERY 3049 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 CORRIDOR 3050 CORRIDOR 3041 CORRIDOR 3037 MEDS 3036 2 2 6 5 JAN. 3044 CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 HOLDING NURSERY 3049 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 CORRIDOR 3050 CORRIDOR 3041 CORRIDOR 3037 MEDS 3036 2 2 OPEN OFFICE 3124 STORAGE 3100 CORRIDOR 3106 CORRIDOR 3099 LIGHT WELL 3098 PUBLIC TOILET 3102 1 2 3 OPEN OFFICE 3124 STORAGE 3100 CORRIDOR 3106 CORRIDOR 3099 LIGHT WELL 3098 PUBLIC TOILET 3102 4 4 2 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E PROJECT NO. - 22-194 6/ 8 / 2 0 2 2 1 2 : 5 2 : 2 0 P M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O LEVEL 3 -HVAC PLANS 22-009 Author Checker 06/08/2022 M1.00 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 1/4" = 1'-0"1 LEVEL 3 - AREA A MECHANICAL DEMOLITION PLAN 1/4" = 1'-0"2 LEVEL 3 - AREA A MECHANICAL NEW PLAN 1/4" = 1'-0"3 LEVEL 3 - AREA B MECHANICAL DEMOLITION PLAN 1/4" = 1'-0"4 LEVEL 3 - AREA B MECHANICAL NEW PLAN KEYED NOTES: SYMBOL USED FOR CALLOUT# 1. REMOVE DIFFUSER AND RELOCATE. REFER TO NEW HVAC PLAN FOR NEW LOCATION AND REQUIREMENTS. 2. EXISTING CEILING DIFFUSER OR EXHAUST GRILLE TO REMAIN. 3. EXISTING CEILING DIFFUSER TO REMAIN. REMOVE TEMPORARILY FOR CEILING REPLACEMENT. REFER TO NEW HVAC PLAN FOR NEW LOCATION AND REQUIREMENTS. 4. EXISTING CEILING DIFFUSER RELOCATED TO THIS LOCATION. COORDINATE WITH ARCHITECTURAL AND ELECTRICAL FOR GRID PLACEMENT. EXTEND/TRIM/MODIFY EXISTING DUCT RUNOUT AS NECESSARY TO ACOMMODATE NEW LOCATION. 5. REMOVE EXISTING SINK AND ALL RELATED ACCESSORIES/APPURTENANCES AND PIPING. REMOVE WATER PIPING BACK TO MAINS AND CAP--NO DEAD LEGS ALLOWED. PATCH WALL TO MATCH EXISTING. COORDINATE EXTENTS OF WASTE AND VENT PIPE DEMOLITION WITH OWNER. 6. REMOVE EXISTING SERVICE SINK AND ALL RELATED ACCESSORIES/APPURTENANCES AND PIPING. REMOVE WATER PIPING BACK TO MAINS AND CAP--NO DEAD LEGS ALLOWED. PATCH WALL AND FLOOR BACK TO MATCH EXISTING. COORDINATE EXTENTS OF WASTE AND VENT PIPING DEMOLITION WITH OWNER. 06/08/2022 009 ELECTRICAL LEGEND - LIGHTING DEVICES ONE LINE SECURITY A AMPERES AC 6" ABOVE BACKSPLASH AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AF AMP FRAME AIC AMPS INTERRUPTING CAPACITY AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BD BOTTOM OF DECK BS BOTTOM OF STRUCTURE C CEILING MOUNTED C CONDUIT CB CIRCUIT BREAKER CF COMPACT FLUORESCENT CKT CIRCUIT CO CONDUIT ONLY, PROVIDE PULL-LINE CT CURRENT TRANSFORMER CTL CONTROL DC DIRECT CURRENT (D) DEMOLITION DEMO DEMOLITION DET DETAIL DTT DOUBLE TWIN TUBE E EMERGENCY (E) EXISTING EC ELECTRICAL CONTRACTOR EL EMERGENCY LIGHT F FUSE (F) FUTURE FACP FIRE ALARM CONTROL PANEL G/GND GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER HH HAND HOLE HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTO HPS HIGH PRESSURE SODIUM HVAC HEATING, VENTILATION, & AIR CONDITIONING IG ISOLATED GROUND IPCO IDAHO POWER COMPANY J-BOX JUNCTION BOX KA KILOAMP KVA KILO VOLT-AMP KW KILOWATT KWH KILOWATT HOUR LCP LIGHTING CONTROL PANEL MB MAIN BREAKER MBR MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MLO MAIN LUGS ONLY MMC MODULAR METERING CENTER MH METAL HALIDE MSB MAIN SWITCH BOARD MTG MOUNTING N NEUTRAL (N) NEW NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN NTS NOT TO SCALE OH OVERHEAD OS OCCUPANCY SENSOR P POLES PC PHOTO-CONTROL PVC POLYVINYL CHLORIDE PWR POWER RE: REFERENCE REC RECEPTACLE (R) RELOCATED SF SQUARE FEET TBD TO BE DETERMINED TDR TIME DELAY RELAY TK TOE KICK TSP TWISTED SHIELDED PAIR TRT TRIPLE TUBE TTB TELEPHONE TERMINAL BOARD (TYP.) TYPICAL UC UNDERCABINET UG UNDERGROUND U.N.O. UNLESS NOTED OTHERWISE V VOLT VA VOLT-AMPERE W WATT WG WIRE GUARD WP WEATHER PROOF/NEMA 3R ELECTRICAL ABBREVIATIONS PROVIDED/ PROVIDE BY INSTALLED/ INSTALL PROVIDE AND INSTALL / PROVIDED AND INSTALLED BY / PROVIDE AND INSTALL NOTE: THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. CIRCUITING SYMBOLS COMMUNICATIONS ELECTRICAL GENERAL NOTESFIRE ALARM - DESIGN BUILD NOTES IC V SP SP TV TV M M CR K JJ JJJ J J J REB OS DS OS PC TC D SOS 2 SS C C X-X T F X XS DUAL LEVEL SWITCHING, INSIDE AND OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY. INDIVIDUAL BREAKER WITH SHUNT TRIP, SIZE AND POLES INDICATED. NEMA 1 UNO INDIVIDUAL BREAKER, SIZE AND POLES INDICATED. NEMA 1 UNO +80" #P ##A #P ##A ##A ##A #P T REFERENCE FIXTURE SCHEDULE FOR MOUNTING TYPE, MOUNTING HEIGHT, AND FIXTURE TYPE. ##A #P DOUBLE FACE EXIT SIGN, CEILING MOUNTED, PROVIDE UNSWITCHED CONDUCTOR. WALL MOUNTED DOUBLE FACE EXIT SIGN PROVIDE UNSWITCHED CONDUCTOR. MOUNT AT +8'-0" UNO. SINGLE FACE EXIT SIGN, CEILING MOUNTED PROVIDE UNSWITCHED CONDUCTOR. WALL MOUNTED SINGLE FACE EXIT SIGN PROVIDE UNSWITCHED CONDUCTOR. MOUNT AT +8'-0" UNO. ARROW INDICATES DIRECTION TO BE SHOWN ON SIGN. 1'X1' LIGHT FIXTURE. 1'X1' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. 1'X4' LIGHT FIXTURE. 1'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. 2'X4' LIGHT FIXTURE. 2'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. 2'X2' LIGHT FIXTURE. 2'X2' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR STRIP LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. STRIP LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR WALL MOUNTED LIGHT FIXTURE. WALL MOUNTED LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. RECESSED LIGHT FIXTURE RECESSED LIGHT FIXTURE. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. ROUND LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE. POLE LIGHT 1 HEAD WITH POLE TIME CLOCK PHOTO CONTROL CELL LOCATED 12" ABOVE ROOF FACING NORTH. EMERGENCY EGRESS LIGHTING. CONNECT TO AN UNSWITCHED CONDUCTOR. INDICATES FIXTURE TYPE. REFER TO FIXTURE SCHEDULE. EXTERIOR WALL PACK EMERGENCY EXTERIOR WALL PACK. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR SWITCH, TYPE AS INDICATED. +46"AFF OCCUPANCY SENSOR. PROVIDE RELAYS AND POWER PACKS AS REQUIRED SINGLE CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNT SINGLE CONVENIENCE OUTLET DUPLEX CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNT DUPLEX CONVENIENCE OUTLET EMERGENCY DUPLEX CONVENIENCE OUTLET, +18" AFF UNO SWITCHED DUPLEX CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNTED SWITCHED DUPLEX CONVENIENCE OUTLET FOURPLEX CONVENIENCE OUTLET. +18"AFF UNO FLOOR MOUNT FOURPLEX CONVENIENCE OUTLET CONNECTION POINT TO EQUIPMENT SPECIFIED, ELECTRICAL CONTRACTOR TO SUPPLY RACEWAY AND CONDUCTORS AND MAKE FINAL CONNECTION TO EQUIPMENT UNDER THIS SECTION. UNO FLOOR MOUNTED CONNECTION POINT, SEE NOTE ABOVE FOR REQUIREMENTS JUNCTION BOX WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO WALL MOUNTED PUSH BUTTON, HANDICAPPED MOUNT AT SWITCH HEIGHT UNO WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO MOTOR STARTER/CONTACTOR, SIZE/POLES NEMA 1 UNO AS INDICATED COMBINATION STARTER AND DISCONNECT, SIZE/POLES, STARTER SIZE AS INDICATED, NEMA 1 UNO MECHANICAL EQUIPMENT CALL OUT SURFACE MULTI-OUTLET RACEWAY EQUIPMENT CABINET FLUSH MOUNTED EQUIPMENT CABINET, SURFACE MOUNTED PANELBOARD. SEE SCHEDULE FOR TYPE. TRANSFORMER POWER POLE - DUAL CHANNEL THERMOSTAT, +46" AFF PROVIDE CONDUIT, J-BOX, CONDUCTORS AS REQUIRED TO CONTROL ASSOCIATED UNITS. UNO COORDINATE WITH DIVISION 15. NON-FUSED DISCONNECT SIZE/ POLES AS INDICATED, NEMA 1 UNO FUSED DISCONNECT SWITCH, SIZE/POLES, FUSE SIZES AS INDICATED, NEMA 1 UNO DELTA WYE TRANSFORMER UNO PANEL BOARD, SEE SCHEDULE FOR TYPE AND SIZE CIRCUIT BREAKER, SIZE AND POLES INDICATED FUSE, SIZE AND TYPE INDICATED, PROVIDE FUSE FOR EACH POLE INTERRUPTER SWITCH, SIZE AND POLES INDICATED FUSED SWITCH, SIZE/POLES AND FUSE SIZE INDICATED DRAW OUT CIRCUIT BREAKER, SIZE AND POLES INDICATED GROUND FAULT PROTECTION TRANSIENT VOLTAGE SURGE SUPPRESSION NEUTRAL METER AND BASE AUTOMATIC TRANSFER SWITCH (ATS) GENERATOR SET, MAIN BREAKER SIZE INDICATED OVERHEAD SERVICE DROP DISCONNECT SWITCH, SIZE AND POLES INDICATED. NEMA 1 UNO MOTOR SHUNT TRIP COIL PAD MOUNT TRANSFORMER DRY TYPE TRANSFORMER CCTV CAMERA POWER SUPPLY CCTV SYSTEM POWER SUPPLY ADJUSTABLE CAMERA (PAN/TILT/ZOOM) FIXED CAMERA CAMERA IN OUTDOOR HOUSING ADJUSTABLE CAMERA (PAN/TILT/ZOOM) IN OUTDOOR HOUSING CCTV OUTLET, +18" UNO CEILING MOUNTED CCTV OUTLET SECURITY SYSTEM KEYPAD CONTROLLER COORDINATE BOX SIZE AND MUDRING WITH VENDOR CEILING MOUNTED MOTION SENSOR WALL MOUNTED MOTION SENSOR, MOUNTING HEIGHT INDICATED PANIC BUTTON - MOUNTED UNDER COUNTER KITCHEN EQUIPMENT CALLOUT TRACK LIGHT FLOOR MOUNTED JUNCTION BOX ADJUSTABLE BREAKER SETTINGS (PER SPECIFICATIONS): 'L'-LONG TIME 'S'-SHORT TIME 'I'-INSTANTANEOUS 'G'-GROUND FAULT 'R'-ENERGY REDUCING MAINTENANCE SWITCH W/STATUS INDICATOR EMERGENCY EGRESS LIGHTING WITH OUT FIXTURE HEADS. CONNECT TO AN UNSWITCHED CONDUCTOR. CARD READER 2 DOUBLE POLE 3 3-WAY 4 4-WAY K KEYED P PILOT LIGHT D DIMMER HP HORSEPOWER RATED TO THERMAL OVERLOAD LV LOW VOLTAGE OS OCCUPANCY SENSOR OR LOW VOLTAGE, MOMENTARY OVERRIDE VS VACANCY SENSOR a SUPERSCRIPT INDICATES LIGHTS TO BE SWITCHED TOGETHER XXX GROUND ROUND EMERGENCY LIGHT FIXTURE. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. WALL MOUNTED EMERGENCY LIGHT FIXTURE. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. DUAL LEVEL SWITCHING WITH OCCUPANCY SENSOR, INSIDE AND OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY. NOTE: THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL SYMBOLS. SOME OF THE SYMBOLS SHOWN MAY NOT HAVE BEEN USED IN THIS DRAWING PACKAGE. EXISTING CONDUIT DOWN CONDUIT UP 6 NEUTRAL CONDUCTORS GROUNDING CONDUCTOR SIZE QUANTITY 1"-4#10,1#10G PANEL HOMERUN. (3/4"-2#12,1#12G CONDUCTORS UNO) RACEWAY A-2,4,6 PANEL NAME CIRCUIT # EM NOTE: CURRENT CARRYING CONDUCTORS LED DRIVER T OCCUPANCY SENSOR WITH MANUAL DIMMING, SET FOR 50% AUTOMATIC ON, AUTOMATIC OFF, WITH MANUAL DIMMING. DESIGNATES CIRCUIT ON EMERGENCY SOURCE UNMARKED CIRCUIT IS CONCEALED IN CEILING OR WALL. MAINTAIN CONDUIT AND CONDUCTOR SIZE THROUGHOUT ENTIRE CIRCUIT. BEGINNING OF INDIVIDUAL CIRCUIT(S), CIRCUIT NUMBER(S) INDICATED. EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE NOT ALLOWED. EACH 1 POLE BREAKER SHALL BE FURNISHED WITH AN INDIVIDUAL DEDICATED NEUTRAL CONDUCTOR.CONDUIT, STUBBED, CAPPED AND MARKED WITH PULL CORD AS SPECIFIED CONCEALED IN FLOOR OR UNDERGROUND JUNCTION BOX FOR FUTURE TELEPHONE/DATA OUTLET. MOUNT AT 18" A.F.F. UNO. PROVIDE SINGLE-GANG MUD RING WITH BLANK COVER PLATE. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING SPACE. FLOOR MOUNTED TELEPHONE/DATA OUTLET. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING. INSTALL QUANTITY OF DATA (#D) AND TELEPHONE (#T) CABLES INDICATED TO THE NEAREST DATA RACK. PROVIDE (2) DATA CABLES IF A CABLE QUANTITY IS NOT INDICATED. INTERCOM SYSTEM CALL BUTTON. +46" UNO. CEILING MOUNTED SPEAKER WITH BACKBOX WALL MOUNTED SPEAKER, WITH BACKBOX +80" UNO VOLUME CONTROL, +46" UNO TELEVISION OUTLET, +18" AFF UNO. PROVIDE 1-1/4" CONDUIT TO NEAREST ACCESSIBLE CEILING SPACE CEILING MOUNTED TELEVISION OUTLET TTB TELEPHONE TERMINAL BOARD CT-XX CABLE TRAY, 4" DEEP, WIRE BASKET STYLE, 'XX' INDICATES WIDTH PROVIDE ALL FITTINGS AND SUPPORT HARDWARE REQUIRED FLOOR MOUNTED BOX FOR FUTURE TELEPHONE/DATA OUTLET. JUNCTION BOX WITH SINGLE-GANG MUD RING. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING SPACE. PROVIDE BLANK COVER PLATE. #D,#T TELEPHONE/DATA OUTLET. MOUNT AT 18" A.F.F. UNO. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING. INSTALL QUANTITY OF DATA (#D) AND TELEPHONE (#T) CABLES INDICATED TO THE NEAREST DATA RACK. PROVIDE (2) DATA CABLES IF A CABLE QUANTITY IS NOT INDICATED. #D,#T USB DUPLEX CONVENIENCE OUTLET, +18" AFF UNO USB FOURPLEX CONVENIENCE OUTLET, +18" AFF UNO RECESSED ENTERTAINMENT BOX A. THE FIRE ALARM SYSTEM WILL BE DESIGN BUILD BY THE CONTRACTOR. THE FIRE ALARM CONTRACTOR SHALL PRODUCE A FIRE ALARM SUBMITTAL THAT INCLUDES ALL DRAWINGS, CALCULATIONS AND CUT SHEETS REQUIRED TO OBTAIN COMPLETE APPROVAL FROM ALL APPROVING AGENCIES. B. THE FIRE ALARM CONTRACTOR SHALL PROVIDE FIRE ALARM SUBMITTALS TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO SUBMITTING TO THE AUTHORITY HAVING JURISDICTION AND AND SHALL NOT PROCEED UNTIL THESE SUBMITTALS HAVE BEEN REVIEWED, APPROVED AND RETURNED. C. REFER TO THE ARCHITECTURAL CODE PLAN(S) FOR THE OCCUPANCY TYPES AND OCCUPANCY LOADS FOR EACH AREA. D. UTILIZE CURRENTLY ADOPTED CODES AND AMENDMENTS FOR FIRE ALARM REQUIREMENTS. E. THE FIRE ALARM CONTRACTOR SHALL PROVIDE AND INSTALL ALL FIRE ALARM INITIATING, MONITORING, INTERFACE AND RELATED DEVICES AND EQUIPMENT AS REQUIRED FOR A COMPLETE AND FUNCTIONING CODE COMPLIANT SYSTEM. F. THE FIRE ALARM SYSTEM SHALL PROVIDE ALL REQUIRED NOTIFICATION THROUGH OUT THE FACILITY. COORDINATE THE MOUNTING HEIGHTS OF THE NOTIFICATION DEVICES WITH THE CEILING AND STRUCTURE HEIGHTS IN THE BUILDING. REFER TO ARCHITECTURAL PLANS FOR CEILING/STRUCTURE INFORMATION. G. PROVIDE ALL IN-DUCT AND/OR DUCT SMOKE DUCT DETECTORS AS REQUIRED. COORDINATE THE FINAL QUANTITY AND LOCATIONS WITH MECHANICAL CONTRACTOR. H. PROVIDE 120V POWER, CONTROL RELAYS AND IN-DUCT DETECTORS FOR ALL SMOKE AND SMOKE/FIRE DAMPERS. COORDINATE WITH MECHANICAL PLANS. I. PROVIDE SMOKE DETECTORS, RELAYS AND RELATED CONNECTIONS FOR ALL DOOR HOLD OPENS AS REQUIRED. J. PROVIDE ALL 120V CIRCUITS AS REQUIRED TO ACCOMMODATE FIRE ALARM CONTROL PANEL, DRY SYSTEM AIR COMPRESSOR(S), NITROGEN GENERATOR(S), FIRE BELLS, NAC EXTENDER PANELS, AMPLIFIER PANELS AND RELATED ITEMS. K. ALL FIRE ALARM CIRCUIT BREAKERS SHALL HAVE A RED HANDLE AND BE LOCKABLE TYPE. L. FIRE ALARM CABLING SHALL BE CONCEALED. AREAS IN WALLS, ABOVE HARD CEILINGS AND SIMILAR (NON-ACCESSIBLE AREAS) SHALL BE IN CONDUIT. EXPOSED CABLING IS NOT ALLOWED. M. PROVIDE ALL DETECTION, MONITOR AND CONTROL DEVICES AS REQUIRED FOR THE ELEVATOR(S). N. THE FIRE ALARM CONTRACTOR SHALL PRODUCE RECORD DOCUMENTS OF THE ACTUAL SYSTEM AS INSTALLED. THE RECORD DOCUMENTS SHALL BE PRODUCED TO THE ACCEPTANCE OF THE ARCHITECT AND ENGINEER. ONE COMPLETE SET OF PRINTED DOCUMENTS AND A PDF VERSION SHALL BE DELIVERED TO THE ARCHITECT. O. INSTALL PLENUM RATED FIRE ALARM CONDUCTORS FROM ALL FIRE ALARM DEVICES INDICATED TO THE FIRE ALARM CONTROL PANEL OR NAC EXTENDER PANEL(S) AS REQUIRED. STUB 3/4" CONDUIT FROM DEVICE TO VOID ABOVE CEILING. PROVIDE NAC EXTENDER PANELS (QUANTITY AS REQUIRED) IN LOCATIONS INDICATED AND CIRCUITING AS REQUIRED FOR A COMPLETE INSTALLATION. CIRCUIT THE FIRE ALARM NOTIFICATION AND INITIATION DEVICES PER THE ELECTRICAL SPECIFICATIONS. FURNISH AND INSTALL ALL APPURTENANCES AND PROGRAMMING REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. REFER TO ELECTRICAL FIRE ALARM SPECIFICATIONS FOR SYSTEM REQUIREMENTS AND SUBMITTAL PROCEDURES. P. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION. A. THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE; THEREFORE, THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL WORK THAT IS REQUIRED BY THE ELECTRICAL CONTRACTOR. B. ALL CONDUIT AND JUNCTION BOXES ARE TO BE CONCEALED UNLESS LOCATED WITHIN DEDICATED ELECTRICAL OR MECHANICAL ROOMS. USE OF SURFACE MOUNTED RACEWAYS IN ALL OTHER SPACES MUST BE APPROVED BY THE ARCHITECT FOR EACH LOCATION. WHERE SURFACE RACEWAYS ARE APPROVED, UTILIZE WIREMOLD, OR APPROVED EQUAL, SURFACE MOUNTED RACEWAYS PAINTED TO MATCH SURROUNDING WALLS. C. REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET HEIGHTS WHERE THE SPECIFIC OUTLET HEIGHT IS NOT INDICATED. REFER TO THE ELECTRICAL LEGEND FOR THE DEFAULT OUTLET HEIGHT WHEN NOT INDICATED ON ELEVATIONS OR ON AT THE DEVICES. D. PROVIDE PULL-LINE IN ALL EMPTY CONDUITS. E. TERMINATE ALL LOW-VOLTAGE CONDUITS WITH INSULATED THROAT BUSHING. F. MECHANICAL EQUIPMENT INDICATED IS SHOWN IN AN APPROXIMATE LOCATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. DEMO: H. THE ELECTRICAL DEMOLITION DRAWING(S) PROVIDED ARE INTENDED TO ASSIST THE ELECTRICAL CONTRACTOR IN ESTABLISHING AREAS REQUIRING DISCONNECTION, REMOVAL, OR RELOCATION OF ELECTRICAL EQUIPMENT, OUTLETS, WIRING, DEVICES, FIXTURES, ETC. AND MAY NOT INDICATE ALL DEVICES OR THE FULL EXTENT OF DEMOLITION AND RECONNECTION WHICH MAY BE REQUIRED. THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY EXAMINE ALL REQUIRED DEMOLITION WORK AND INCLUDE ALL LABOR AND INCIDENTALS THAT WILL BE NECESSARY TO PERFORM DEMOLITION RECONNECTION AND TEMPORARY POWER CONNECTIONS IN THE BID. I. ALL ELECTRICAL DEVICES AND WALLS INDICATED ON THE ELECTRICAL DEMOLITION DRAWING(S) ARE TO REMAIN UNLESS OTHERWISE NOTED. ST GFP LSIGR S M TVSS HC # # # # # # PANEL NAME VOLTAGE PHASE N 100A 3P M J EG P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E PROJECT NO. - 22-194 6/ 8 / 2 0 2 2 1 2 : 3 2 : 5 6 P M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O ELECTRICAL COVER SHEET 22-009 SKB MNB 06/08/2022 E0.00 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 06/08/2022 010 OS OS OS OSCR JAN. 3044 CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 HOLDING NURSERY 3049 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 CORRIDOR 3050 CORRIDOR 3037 MEDS 3036 CORRIDOR 3033 (R) (E) (D) (E) (E) (E) 1 1 JAN. 3044 CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 HOLDING NURSERY 3049 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 CORRIDOR 3050 CORRIDOR 3037 MEDS 3036 CORRIDOR 3033 (N) (E) (E)(E) (E) (R) 3 4 (E) (E) (E)(E) (R) (R) (D) 5 5 STORAGE 3100 PUBLIC TOILET 3102 OPEN OFFICE 3124 CORRIDOR 3106 CORRIDOR 3106 CORRIDOR 3099 (E) (E) (E)(E) (R) (R) 2 4 6 6 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E PROJECT NO. - 22-194 6/ 8 / 2 0 2 2 1 2 : 3 2 : 5 6 P M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O LEVEL 3 -LIGHTING PLANS 22-009 SKB MNB 06/08/2022 E1.00 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 1/4" = 1'-0"1 LEVEL 3 - AREA A LIGHTING DEMO PLAN 1/4" = 1'-0"2 LEVEL 3 - AREA A LIGHTING INSTALL PLAN 1/4" = 1'-0"3 LEVEL 3 - AREA B LIGHTING DEMO PLAN 1/4" = 1'-0"4 LEVEL 3 - AREA B LIGHTING INSTALL PLAN KEYED NOTES: SYMBOL USED FOR CALLOUT# 1. EXISTING WALL TO BE REMOVED. REMOVE ALL EXISTING DEVICES AND JUNCTION BOXES. RE-ROUTE CONDUIT AND CONDUCTORS AS REQUIRED TO MAINTAIN POWER TO ALL DOWN STREAM DEVICE THAT ARE EXISTING TO REMAIN. 2. CONNECT TO THE NEAREST UNSWITCHED CIRCUIT. 3. RECONNECT TO EXISTING CIRCUIT. 4. NEW OCCUPANCY SENSOR SWITCH. MATCH COLOR AND STYLE OF EXISTING SWITCHES. 5. EXISTING LIGHTS TO BE RELOCATED. SEE LIGHTING INSTALL PLAN. 6. RELOCATED LIGHTS. 06/08/2022 011 CR STUB UP 4"ABOVE CEILING 4-11/16" SQUARE JUNCTION BOX WITH SINGLE GANG MUDRING RANDL TB55057 OR EQUAL ACCESSIBLE CEILING FINISHED FLOOR SINGLE GANG DEVICE COVER RANDL D-51GO12 OR EQUAL WALL STUD ANTI-SHORT PLASTIC BUSHING ARLINGTON INDUSTRIES EMT75 OR EQUAL VA R I E S FLOOR PLATE TOP PLATE ELECTRICAL CONTRACTOR RESPONSIBLE FOR INSTALLATION OF CARD READER ROUGH-IN TYPICAL DETAIL - ACTUAL INSTALLATION MAY VARY 3/4"C EMT WITH PULLSTRING 48 " 40" ELECTRIC STRIKE SEE ARCHITECTURAL HARDWARE SCHEDULE HOLLOW STEEL DOOR FRAME STUB 3/4"C INTO DOOR FRAME SEE ARCHITECTURAL DOOR SCHEDULE JAN. 3044 CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 HOLDING NURSERY 3049 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 CORRIDOR 3050 CORRIDOR 3041 CORRIDOR 3037 MEDS 3036 (R) +48 GFI(E) 2 JAN. 3044 CLEAN 3040 JAN. 3047 SOILED 3045 STAFF TOILET 3046 HOLDING NURSERY 3049 TUB JACUZZI 3039 STORAGE 3048 NOURISHMENT 3043 NURSE STATION 3035 CORRIDOR 3050 CORRIDOR 3041 CORRIDOR 3037 MEDS 3036 (R) +48 GFI(E) 3 OPEN OFFICE 3124 STORAGE 3100 CORRIDOR 3106 CORRIDOR 3099 LIGHT WELL 3098 PUBLIC TOILET 3102 (E) (E) (E) (E) OPEN OFFICE 3124 STORAGE 3100 CORRIDOR 3106 CORRIDOR 3099 LIGHT WELL 3098 PUBLIC TOILET 3102 (E) (E) (E)(E) 1 4 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E PROJECT NO. - 22-194 6/ 8 / 2 0 2 2 1 2 : 3 2 : 5 6 P M MA D I S O N M E M O R I A L H O S P I T A L S T O R A G E R O O M S A D D I T I O N 45 0 E A S T M A I N S T R E E T , R E X B U R G , I D A H O LEVEL 3 -ELECTRICAL PLANS 22-009 SKB MNB 06/08/2022 E2.00 PE R M I T S E T : 0 6 . 0 8 . 2 0 2 2 1/4" = 1'-0"1 LEVEL 3 - AREA A ELECTRICAL DEMO PLAN 1/4" = 1'-0"2 LEVEL 3 - AREA A ELECTRICAL INSTALL PLAN 1/4" = 1'-0"3 LEVEL 3 - AREA B ELECTRICAL DEMO PLAN 1/4" = 1'-0"4 LEVEL 3 - AREA B ELECTRICAL INSTALL PLAN KEYED NOTES: SYMBOL USED FOR CALLOUT# 1. CONNECT TO NEAREST AVAILABLE CIRCUIT IN THE ROOM. 2. EXISTING DEVICE TO BE REMOVED AND RELOCATED. SEE ELECTRICAL INSTALL PLAN. REMOVE UNUSED CONDUIT, CONDUCTORS, AND J-BOXES. 3. RELOCATED DEVICE. EXTEND CIRCUIT TO NEW LOCATION. 4. INSTALL CARD READER ROUGH-IN. SEE DETAIL ON THIS SHEET. COORDINATE CARD READER INSTALLATION WITH HOSPITAL ACCESS CONTROL CONTRACTOR. 1" = 1'-0"5 CARD READER BOX ELEVATION 06/08/2022 012