Loading...
HomeMy WebLinkAboutSTRUCTURAL CALCS - 21-00789 - Rocky Mountain Power - Mechanic ShopFROST Structural Engineering 1020 Lincoln Road Phone: 208.227.8404 Idaho Falls, ID 83401 Fax: 208.227.8405 www.frost-structural.com Project: Rocky Mountain Power Mechanics Shop Client: TWebb Construction Project No.: IF21-411 Date: Engineer : SEAL: FSE November 3, 2021 November 3, 2021 STRUCTURAL CALCULATIONS DBP 1 of 30 STEEL BUILDING FOUNDATION DESIGN FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop 2 of 30 1-A P= 5.2 U= 0.8 H= 1.8 REACTION KEY PLAN A-1 P= 8.4 U= 8.4 H= 3.3 1-B P= 12.7 U= 7.5 H= 3.1 1-C P= 13.7 U= 9.3 H= 2.9 1-D P= 5.0 U= 1.3 H= 1.5 2-A P= 32.5 U= 5.0 H= 9.0 A-2 P= 8.4 U= 8.4 H= 3.3 2-D P= 31.6 U= 6.8 H= 9.0 3-A P= 30.0 U= 4.6 H= 7.5 3-D P= 28.9 U= 9.0 H= 7.6 4-A P= 30.0 U= 4.6 H= 7.5 4-D P= 28.9 U= 9.0 H= 7.6 5-A P= 4.8 U= 0.7 H= 1.8 5-D P= 4.7 U= 1.2 H= 1.5 5-B P= 11.8 U= 7.0 H= 3.1 5-C P= 12.7 U= 8.7 H= 2.9 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop BU I L D I N G M A R K : Ro c k y M t n EN G I N E E R I N G P R O P E R T I E S : Al l o w a b l e B e a r i n g P r e s s u r e = Fr o s t D e p t h o r d e p t h o f F o o t i n g = So i l W e i g h t = Co n t i n u o u s F o o t i n g W i d t h = Pa s s i v e s o i l P r e s s u r e = Co n t i n u o u s F o o t i n g T h i c k n e s s = Fr i c t i o n C o e f f i c i e n t = Fo o t i n g S t e m W i d t h = Co n t r i b u t i n g S l a b / F o o t i n g L e n g t h = Sl a b T h i c k n e s s = Fy = S l a b R e i n f o r c e m e n t A r e a p e r F o o t = FO O T I N G D E S I G N : Gr i d l i n e s / N a m e Ve r t i c a l Fo r c e ( k i p s ) Up l i f t F o r c e (k i p s ) Ho r i z o n t a l Fo r c e - O u t (k i p s ) Co l u m n Lo c a t i o n Fo o t i n g Th i c k n e s s (i n ) Fo o t i n g Wi d t h ( f t ) Co l u m n De a d L o a d (k i p s ) Be a r i n g Pr o v i d e d (k i p s ) Re s i s t i n g Up l i f t ( k i p s ) Re s i s t i n g Ho r i z o n t a l Fo r c e ( k i p s ) B e a r i n g U p l i f t H o r i z o n t a l Ha i r p i n to b e Us e d ? Ha i r p i n Ba r S i z e Ha i r p i n An g l e (T y p i c a l l y 0 o r 6 0 ) Ha i r p i n Re q u i r e d Ba r A e a ( 1 le g ) Re q u i r e d Ha i r p i n L e g Le n g t h ( f t ) Sl a b A r e a Re q u i r e d f o r Ha i r p i n - N o Re b a r i n S l a b H a i r p i n 1- A 13 . 6 8 . 4 1 . 8 E x t e r i o r C o r n e r 12 5 . 5 1. 3 6 45 . 4 1 7 . 9 4 . 8 ok o k o k 0. 0 4 G r a d e B e a m 0 . 0 0 1- B 12 . 7 7 . 5 3 . 1 E x t e r i o r W a l l 12 4 1. 2 7 24 . 0 1 5 . 2 3 . 8 ok o k - Ye s 4 6 0 0. 0 7 5 . 7 7 5 7 . 4 7 ok 1- C 13 . 7 9 . 3 2 . 9 E x t e r i o r W a l l 12 4 1. 3 7 24 . 0 1 5 . 2 3 . 3 ok o k - Ye s 4 6 0 0. 0 7 5 . 7 7 6 5 . 4 7 ok 1- D 5. 0 1 . 3 1 . 5 E x t e r i o r C o r n e r 12 3 0. 5 0 13 . 5 9 . 9 3 . 4 ok o k o k 0. 0 3 G r a d e B e a m 0 . 0 0 2- A 40 . 9 8 . 4 9 . 0 E x t e r i o r W a l l 12 5 . 5 4. 0 9 45 . 4 2 1 . 1 6 . 3 ok o k - Ye s 5 6 0 0. 2 2 5 . 7 7 4 6 2 . 6 2 ok 2- D 31 . 6 6 . 8 9 . 0 E x t e r i o r W a l l 12 5 3. 1 6 37 . 5 1 9 . 0 5 . 7 ok o k - Ye s 5 6 0 0. 2 2 5 . 7 7 4 9 8 . 2 5 ok 3- A 30 . 0 4 . 6 7 . 5 E x t e r i o r W a l l 12 5 3. 0 0 37 . 5 1 9 . 0 6 . 2 ok o k - Ye s 5 6 0 0. 1 8 5 . 7 7 3 2 1 . 6 1 ok 3- D 28 . 9 9 . 0 7 . 6 E x t e r i o r W a l l 12 5 2. 8 9 37 . 5 1 9 . 0 5 . 1 ok o k - Ye s 5 6 0 0. 1 8 5 . 7 7 4 0 3 . 3 7 ok 4- A 30 . 0 4 . 6 7 . 5 E x t e r i o r W a l l 12 5 3. 0 0 37 . 5 1 9 . 0 6 . 2 ok o k - Ye s 5 6 0 0. 1 8 5 . 7 7 3 2 1 . 6 1 ok 4- D 28 . 9 9 . 0 7 . 6 E x t e r i o r W a l l 12 5 2. 8 9 37 . 5 1 9 . 0 5 . 1 ok o k - Ye s 5 6 0 0. 1 8 5 . 7 7 4 0 3 . 3 7 ok 5- A 4. 8 0 . 7 1 . 8 E x t e r i o r C o r n e r 12 3 0. 4 8 13 . 5 9 . 9 3 . 6 ok o k o k 0. 0 4 G r a d e B e a m 0 . 0 0 5- B 11 . 8 7 . 0 3 . 1 E x t e r i o r W a l l 12 4 1. 1 8 24 . 0 1 5 . 2 3 . 9 ok o k - Ye s 4 6 0 0. 0 7 5 . 7 7 5 0 . 9 1 ok 5- C 12 . 7 8 . 7 2 . 9 E x t e r i o r W a l l 12 4 1. 2 7 24 . 0 1 5 . 2 3 . 5 ok o k - Ye s 4 6 0 0. 0 7 5 . 7 7 5 7 . 4 7 ok 5- D 4. 7 1 . 2 1 . 5 E x t e r i o r C o r n e r 12 3 0. 4 7 13 . 5 9 . 9 3 . 4 ok o k o k 0. 0 3 G r a d e B e a m 0 . 0 0 0. 2 5 16 ' ' 10 ' ' 11 0 p c f 15 0 p s f / f t 5' ' ME T A L B U I L D I N G F O U N D A T I O N D E S I G N 36 ' ' 15 0 0 p s f 8' ' 4. 5 ' 60 k s i 0. 1 3 1 i n ^ 2 / f t 3 o f 3 0 F R O S T S t r u c t u r a l E n g i n e e r i n g P r o j e c t N a m e : P r o j e c t N o . : E n g . : D a t e : S h e e t : D B P F S E 1 1 / 0 3 / 2 1 I F 2 1 - 4 1 1 R o c k y M o u n t a i n P o w e r M e c h a n i c s S h o p Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =1.36 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =12.24 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 21.2 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =5.5 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =5.5 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%738 >89 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:122 >19 OK q min (psf) =450 q max (psf) =450 OK qu-max (psf) =701 qu at edge of base (psf) =701 qu-min (psf) =701 qu at edge of base (psf) =701 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 2.25 Bar size =#5 p =0.0004 Fy (psi) = 60000 Mu (k-ft) = 1.78 area of bar = 0.31 Min p =0.0006 Ld1 (in) =30.0 d (in)= 8.69 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.05 Spacing (in) = 122 Use p =0.0006 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 44.7 OK Check Development Length L' short (ft) = 2.25 Bar size =#5 p =0.0002 Fy (psi) = 60000 Mu (k-ft) = 0.89 area of bar = 0.31 Min p =0.0003 Ld1 (in) =30.0 d (in)= 8.06 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.02 Spacing (in) = 245 Use p =0.0003 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 44.1 OK 1-A Use: w/ 1 #5 Top and Bottom 5.5 feet long x 5.5 feet wide x 12'' thick Footing Each Way 1-A Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 4 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =1.27 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =11.43 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 19.8 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =4 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =4 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%744 >80 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:123 >16 OK q min (psf) =794 q max (psf) =794 OK qu-max (psf) =1238 qu at edge of base (psf) =1238 qu-min (psf) =1238 qu at edge of base (psf) =1238 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 1.50 Bar size =#4 p =0.0003 Fy (psi) = 60000 Mu (k-ft) = 1.39 area of bar = 0.20 Min p =0.0005 Ld1 (in) =24.0 d (in)= 8.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.04 Spacing (in) = 101 Use p =0.0005 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 35.8 OK Check Development Length L' short (ft) = 1.50 Bar size =#4 p =0.0002 Fy (psi) = 60000 Mu (k-ft) = 0.70 area of bar = 0.20 Min p =0.0002 Ld1 (in) =24.0 d (in)= 8.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.02 Spacing (in) = 203 Use p =0.0002 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 35.3 OK 1-B Use: w/ 1 #4 Top and Bottom 4.0 feet long x 4.0 feet wide x 12'' thick Footing Each Way 1-B Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 5 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =1.37 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =12.33 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 21.4 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =4 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =4 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%744 >86 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:123 >17 OK q min (psf) =856 q max (psf) =856 OK qu-max (psf) =1336 qu at edge of base (psf) =1336 qu-min (psf) =1336 qu at edge of base (psf) =1336 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 1.50 Bar size =#4 p =0.0004 Fy (psi) = 60000 Mu (k-ft) = 1.50 area of bar = 0.20 Min p =0.0005 Ld1 (in) =24.0 d (in)= 8.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.04 Spacing (in) = 94 Use p =0.0005 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 35.8 OK Check Development Length L' short (ft) = 1.50 Bar size =#4 p =0.0002 Fy (psi) = 60000 Mu (k-ft) = 0.75 area of bar = 0.20 Min p =0.0003 Ld1 (in) =24.0 d (in)= 8.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.02 Spacing (in) = 188 Use p =0.0003 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 35.3 OK 1-C Use: w/ 1 #4 Top and Bottom 4.0 feet long x 4.0 feet wide x 12'' thick Footing Each Way 1-C Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 6 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =0.50 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =4.50 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 7.8 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =3 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =3 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =10 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%574 >32 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:86 >6 OK q min (psf) =556 q max (psf) =556 OK qu-max (psf) =867 qu at edge of base (psf) =867 qu-min (psf) =867 qu at edge of base (psf) =867 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 1.00 Bar size =#4 p =0.0002 Fy (psi) = 60000 Mu (k-ft) = 0.43 area of bar = 0.20 Min p =0.0002 Ld1 (in) =24.0 d (in)= 6.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.01 Spacing (in) = 252 Use p =0.0002 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 27.8 OK Check Development Length L' short (ft) = 1.00 Bar size =#4 p =0.0001 Fy (psi) = 60000 Mu (k-ft) = 0.22 area of bar = 0.20 Min p =0.0001 Ld1 (in) =24.0 d (in)= 6.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.01 Spacing (in) = 504 Use p =0.0001 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 27.3 OK 1-D Use: w/ 1 #4 Top and Bottom 3.0 feet long x 3.0 feet wide x 10'' thick Footing Each Way 1-D Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 7 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =4.09 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =36.81 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 63.8 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =5.5 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =5.5 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%738 >268 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:122 >58 OK q min (psf) =1352 q max (psf) =1352 OK qu-max (psf) =2109 qu at edge of base (psf) =2109 qu-min (psf) =2109 qu at edge of base (psf) =2109 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 2.25 Bar size =#5 p =0.0013 Fy (psi) = 60000 Mu (k-ft) = 5.34 area of bar = 0.31 Min p =0.0018 Ld1 (in) =30.0 d (in)= 8.69 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.14 Spacing (in) = 40 Use p =0.0018 Ld3 (in) =12 Total Bars = 2 Less than pmax, OK Available Ld (in) = 44.7 OK Check Development Length L' short (ft) = 2.25 Bar size =#5 p =0.0007 Fy (psi) = 60000 Mu (k-ft) = 2.67 area of bar = 0.31 Min p =0.0009 Ld1 (in) =30.0 d (in)= 8.06 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.07 Spacing (in) = 81 Use p =0.0009 Ld3 (in) =12 Total Bars = 2 Less than pmax, OK Available Ld (in) = 44.1 OK 2-A Use: w/ 2 #5 Top and Bottom 5.5 feet long x 5.5 feet wide x 12'' thick Footing Each Way 2-A Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 8 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =3.16 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =28.44 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 49.3 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =5 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =5 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%738 >210 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:122 >43 OK q min (psf) =1264 q max (psf) =1264 OK qu-max (psf) =1972 qu at edge of base (psf) =1972 qu-min (psf) =1972 qu at edge of base (psf) =1972 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 2.00 Bar size =#5 p =0.0010 Fy (psi) = 60000 Mu (k-ft) = 3.94 area of bar = 0.31 Min p =0.0013 Ld1 (in) =30.0 d (in)= 8.69 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.10 Spacing (in) = 55 Use p =0.0013 Ld3 (in) =12 Total Bars = 2 Less than pmax, OK Available Ld (in) = 41.7 OK Check Development Length L' short (ft) = 2.00 Bar size =#5 p =0.0005 Fy (psi) = 60000 Mu (k-ft) = 1.97 area of bar = 0.31 Min p =0.0007 Ld1 (in) =30.0 d (in)= 8.06 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.05 Spacing (in) = 110 Use p =0.0007 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 41.1 OK 2-D Use: w/ 2 #5 Top and Bottom 5.0 feet long x 5.0 feet wide x 12'' thick Footing Each Way 2-D Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 9 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =3.00 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =27.00 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 46.8 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =5 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =5 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%738 >199 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:122 >41 OK q min (psf) =1200 q max (psf) =1200 OK qu-max (psf) =1872 qu at edge of base (psf) =1872 qu-min (psf) =1872 qu at edge of base (psf) =1872 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 2.00 Bar size =#5 p =0.0009 Fy (psi) = 60000 Mu (k-ft) = 3.74 area of bar = 0.31 Min p =0.0012 Ld1 (in) =30.0 d (in)= 8.69 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.10 Spacing (in) = 57 Use p =0.0012 Ld3 (in) =12 Total Bars = 2 Less than pmax, OK Available Ld (in) = 41.7 OK Check Development Length L' short (ft) = 2.00 Bar size =#5 p =0.0005 Fy (psi) = 60000 Mu (k-ft) = 1.87 area of bar = 0.31 Min p =0.0007 Ld1 (in) =30.0 d (in)= 8.06 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.05 Spacing (in) = 116 Use p =0.0007 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 41.1 OK 3-A Use: w/ 2 #5 Top and Bottom 5.0 feet long x 5.0 feet wide x 12'' thick Footing Each Way 3-A Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 10 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =2.89 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =26.01 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 45.1 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =5 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =5 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%738 >192 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:122 >40 OK q min (psf) =1156 q max (psf) =1156 OK qu-max (psf) =1803 qu at edge of base (psf) =1803 qu-min (psf) =1803 qu at edge of base (psf) =1803 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 2.00 Bar size =#5 p =0.0009 Fy (psi) = 60000 Mu (k-ft) = 3.61 area of bar = 0.31 Min p =0.0012 Ld1 (in) =30.0 d (in)= 8.69 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.09 Spacing (in) = 60 Use p =0.0012 Ld3 (in) =12 Total Bars = 2 Less than pmax, OK Available Ld (in) = 41.7 OK Check Development Length L' short (ft) = 2.00 Bar size =#5 p =0.0005 Fy (psi) = 60000 Mu (k-ft) = 1.80 area of bar = 0.31 Min p =0.0006 Ld1 (in) =30.0 d (in)= 8.06 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.05 Spacing (in) = 120 Use p =0.0006 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 41.1 OK 3-D Use: w/ 2 #5 Top and Bottom 5.0 feet long x 5.0 feet wide x 12'' thick Footing Each Way 3-D Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 11 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =3.00 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =27.00 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 46.8 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =5 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =5 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%738 >199 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:122 >41 OK q min (psf) =1200 q max (psf) =1200 OK qu-max (psf) =1872 qu at edge of base (psf) =1872 qu-min (psf) =1872 qu at edge of base (psf) =1872 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 2.00 Bar size =#5 p =0.0009 Fy (psi) = 60000 Mu (k-ft) = 3.74 area of bar = 0.31 Min p =0.0012 Ld1 (in) =30.0 d (in)= 8.69 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.10 Spacing (in) = 57 Use p =0.0012 Ld3 (in) =12 Total Bars = 2 Less than pmax, OK Available Ld (in) = 41.7 OK Check Development Length L' short (ft) = 2.00 Bar size =#5 p =0.0005 Fy (psi) = 60000 Mu (k-ft) = 1.87 area of bar = 0.31 Min p =0.0007 Ld1 (in) =30.0 d (in)= 8.06 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.05 Spacing (in) = 116 Use p =0.0007 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 41.1 OK 4-A Use: w/ 2 #5 Top and Bottom 5.0 feet long x 5.0 feet wide x 12'' thick Footing Each Way 4-A Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 12 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =2.89 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =26.01 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 45.1 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =5 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =5 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%738 >192 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:122 >40 OK q min (psf) =1156 q max (psf) =1156 OK qu-max (psf) =1803 qu at edge of base (psf) =1803 qu-min (psf) =1803 qu at edge of base (psf) =1803 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 2.00 Bar size =#5 p =0.0009 Fy (psi) = 60000 Mu (k-ft) = 3.61 area of bar = 0.31 Min p =0.0012 Ld1 (in) =30.0 d (in)= 8.69 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.09 Spacing (in) = 60 Use p =0.0012 Ld3 (in) =12 Total Bars = 2 Less than pmax, OK Available Ld (in) = 41.7 OK Check Development Length L' short (ft) = 2.00 Bar size =#5 p =0.0005 Fy (psi) = 60000 Mu (k-ft) = 1.80 area of bar = 0.31 Min p =0.0006 Ld1 (in) =30.0 d (in)= 8.06 bar diameter = 0.625 Max p =0.0134 Ld2 (in) =15 As req(in^2/ft)= 0.05 Spacing (in) = 120 Use p =0.0006 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 41.1 OK 4-D Use: w/ 2 #5 Top and Bottom 5.0 feet long x 5.0 feet wide x 12'' thick Footing Each Way 4-D Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 13 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =0.48 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =4.32 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 7.5 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =3 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =3 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =10 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%574 >30 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:86 >5 OK q min (psf) =533 q max (psf) =533 OK qu-max (psf) =832 qu at edge of base (psf) =832 qu-min (psf) =832 qu at edge of base (psf) =832 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 1.00 Bar size =#4 p =0.0002 Fy (psi) = 60000 Mu (k-ft) = 0.42 area of bar = 0.20 Min p =0.0002 Ld1 (in) =24.0 d (in)= 6.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.01 Spacing (in) = 262 Use p =0.0002 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 27.8 OK Check Development Length L' short (ft) = 1.00 Bar size =#4 p =0.0001 Fy (psi) = 60000 Mu (k-ft) = 0.21 area of bar = 0.20 Min p =0.0001 Ld1 (in) =24.0 d (in)= 6.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.01 Spacing (in) = 525 Use p =0.0001 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 27.3 OK 5-A Use: w/ 1 #4 Top and Bottom 3.0 feet long x 3.0 feet wide x 10'' thick Footing Each Way 5-A Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 14 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =1.18 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =10.62 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 18.4 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =4 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =4 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%744 >74 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:123 >15 OK q min (psf) =738 q max (psf) =738 OK qu-max (psf) =1151 qu at edge of base (psf) =1151 qu-min (psf) =1151 qu at edge of base (psf) =1151 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 1.50 Bar size =#4 p =0.0003 Fy (psi) = 60000 Mu (k-ft) = 1.29 area of bar = 0.20 Min p =0.0004 Ld1 (in) =24.0 d (in)= 8.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.03 Spacing (in) = 109 Use p =0.0004 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 35.8 OK Check Development Length L' short (ft) = 1.50 Bar size =#4 p =0.0002 Fy (psi) = 60000 Mu (k-ft) = 0.65 area of bar = 0.20 Min p =0.0002 Ld1 (in) =24.0 d (in)= 8.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.02 Spacing (in) = 219 Use p =0.0002 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 35.3 OK 5-B Use: w/ 1 #4 Top and Bottom 4.0 feet long x 4.0 feet wide x 12'' thick Footing Each Way 5-B Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 15 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =1.27 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =11.43 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 19.8 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =4 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =4 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =12 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%744 >80 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:123 >16 OK q min (psf) =794 q max (psf) =794 OK qu-max (psf) =1238 qu at edge of base (psf) =1238 qu-min (psf) =1238 qu at edge of base (psf) =1238 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 1.50 Bar size =#4 p =0.0003 Fy (psi) = 60000 Mu (k-ft) = 1.39 area of bar = 0.20 Min p =0.0005 Ld1 (in) =24.0 d (in)= 8.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.04 Spacing (in) = 101 Use p =0.0005 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 35.8 OK Check Development Length L' short (ft) = 1.50 Bar size =#4 p =0.0002 Fy (psi) = 60000 Mu (k-ft) = 0.70 area of bar = 0.20 Min p =0.0002 Ld1 (in) =24.0 d (in)= 8.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.02 Spacing (in) = 203 Use p =0.0002 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 35.3 OK 5-C Use: w/ 1 #4 Top and Bottom 4.0 feet long x 4.0 feet wide x 12'' thick Footing Each Way 5-C Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 16 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Concrete Pad Footing Strength Design per ACI 318-11 Mark: Material Data M DL (k-ft) =0.00 Allowable q (psf) =1500 P DL (k) =0.47 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85 P LL (k) =4.23 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40 Pu (k) = 7.3 Mu (k-ft) = 0.00 Bars #4 and bigger, Fy (ksi) = 60 e (ft) = 0.00 within middle 3rd Footing Dimensions: Column/Pier Base: Shear Check: Long (ft) =3 Long Direction (in) =12 Punching Vc (psi) = 170 Short (ft) =3 Short Direction (in)=12 Wide Bm Vc (psi) = 85 Thickness (in) =10 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in) % in center band B=100%574 >30 OK Punching Shear Resistance (k) > Applied Force (k) Bearing Pressures:86 >5 OK q min (psf) =522 q max (psf) =522 OK qu-max (psf) =815 qu at edge of base (psf) =815 qu-min (psf) =815 qu at edge of base (psf) =815 Reinforcing: Reinforcement Top and Bottom(Y/N) =Y Base As(min) on calc'd As(4/3) (Y/N) =Y Check Development Length L' long (ft) = 1.00 Bar size =#4 p =0.0002 Fy (psi) = 60000 Mu (k-ft) = 0.41 area of bar = 0.20 Min p =0.0002 Ld1 (in) =24.0 d (in)= 6.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.01 Spacing (in) = 268 Use p =0.0002 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 27.8 OK Check Development Length L' short (ft) = 1.00 Bar size =#4 p =0.0001 Fy (psi) = 60000 Mu (k-ft) = 0.20 area of bar = 0.20 Min p =0.0001 Ld1 (in) =24.0 d (in)= 6.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.01 Spacing (in) = 536 Use p =0.0001 Ld3 (in) =12 Total Bars = 1 Less than pmax, OK Available Ld (in) = 27.3 OK 5-D Use: w/ 1 #4 Top and Bottom 3.0 feet long x 3.0 feet wide x 10'' thick Footing Each Way 5-D Loads: (U = 1.2DL + 1.6LL) Long Direction Check p Short Direction Check p 17 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop 18 of 30 INTERIOR MEZZANINE DESIGN FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Design Code: 2018 International Building Code Risk Category =II [see ASCE 7 Table 1.5-1] Floor Loads: floor coverings 5.0 3/4" plywood or OSB 2.5 wood joists at 16" o.c.3.5 10" batt insulation (R-30)1.0 1/2" gypboard 2.2 mechanical/miscellaneous 0.8 DL =15.0 psf LL joist LL beam TL LL (storage) =125 psf L/360 L/360 L/240 Interior Walls: 5/8" gypboard 2.8 1/2" plywood or OSB (where occurs)1.7 2x wood studs at 16" o.c.1.2 5/8" gypboard 2.8 miscellaneous 1.5 DL =10.0 psf L/240 Design Gravity Loads deflection limits deflection limits 19 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Design Code: 2018 International Building Code Risk Category =II [see ASCE 7 Table 1.5-1] Seismic Loads: Equivalent Lateral Force Procedure 1.00 D Mapped Spectral Response Accelerations: S1 .................0.366 g SS .................0.143 g Design Spectral Response Accelerations: SD1 .................0.221 g SDS .................0.368 g D Seismic Force-Resisting System(s): ................. R .................6.5 Ωo .................3 Cd .................4 Cs .................0.057 Seismic Design Category ....................................... Lateral System Design Lateral Loads Light-frame (wood) walls sheathed with wood structural panels rated Analysis Procedure: ............................................... Importance Factor .................................................. Site Class ............................................................... 20 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Design Code: 2018 International Building Code Risk Category =II [see ASCE 7 Table 1.5-1] Foundation Design: Conventional Spread Footings Presumptive Load-Bearing Values (Table 1806.2) 1500 psf 150 pcf 0.25 36 inches Foundation Design Frost Depth............ Allowable Bearing Pressure............ Passive Pressure............ Foundation Type ............................................. Design Basis: Source .......................................................... Sliding Coefficient............ 21 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Mark:WJ1 DL(psf) LL(psf) LL w(plf) TL w(plf) RDL = 112 lbs Span (ft) =11.0 lu (ft) =2.0 load 15 125 167 187 RLL = 931 lbs Spacing (in) =16.0 CD =1.00 misc.0 0 0 0 RTL (left)=1042 lbs DLL < L /360 Cr =1.15 167 plf 187 plf DTOTAL < L /240 RDL = 112 lbs DL(lbs) LL(lbs) x(ft) RLL = 931 lbs Joist Bearing Length (in) =2 Pt. Load 0 0 0 RTL (right) =1042 lbs Web Stiffener? (Y/N) :N Pt. Load 0 0 0 Mmax = (1)2x14 Vall. (lbs) =2743 38% 1655 63% 1675 62% 1615 65% 1785 58% 1420 73% Rall. (lbs) =1875 56% 1070 97% 1211 86% 1063 98% 1093 95% 1224 85% Mall. (ft-lbs) =3407 85% 3795 77% 4060 72% 6445 45% 4685 62% 3545 82% DLL 0.118 L / 1119 0.220 L / 601 0.212 L / 623 0.171 L / 772 0.217 L / 607 0.206 L / 642 DTOTAL 0.132 L / 999 0.246 L / 537 0.237 L / 556 0.192 L / 689 0.243 L / 542 0.230 L / 573 Nat. freq., f (Hz)29.6 24.3 24.5 28.4 24.5 24.9 Selection (A - F):B WJ1 Use:11 7/8" TJI 210 at 16'' o.c. Mark:WJ2 DL(psf) LL(psf) LL w(plf) TL w(plf) RDL = 41 lbs Span (ft) =4.0 lu (ft) =2.0 load 15 100 133 153 RLL = 276 lbs Spacing (in) =16.0 CD =1.00 misc.0 0 0 0 RTL (left)=318 lbs DLL < L /360 Cr =1.15 133 plf 153 plf DTOTAL < L /240 RDL = 41 lbs DL(lbs) LL(lbs) x(ft) RLL = 276 lbs Joist Bearing Length (in) =1.75 Pt. Load 0 0 0 RTL (right) =318 lbs Web Stiffener? (Y/N) :N Pt. Load 0 0 0 Mmax = (1)2x8 Vall. (lbs) =1501 21% 1560 20% 1625 20% 1335 24% 1785 18% 1420 22% Rall. (lbs) =1641 19% 910 35% 950 33% 870 37% 1015 31% 950 33% Mall. (ft-lbs) =1360 24% 3160 10% 3150 10% 3100 11% 4685 7% 3640 9% DLL 0.010 L / 1500+ 0.008 L / 1500+ 0.007 L / 1500+ 0.008 L / 1500+ 0.007 L / 1500+ 0.007 L / 1500+ DTOTAL 0.012 L / 1500+0.009 L / 1500+0.008 L / 1500+0.009 L / 1500+0.008 L / 1500+0.008 L / 1500+ Nat. freq., f (Hz)90.6 169.5 168.9 163.4 185.3 174.5 Selection (A - F):A WJ2 Use: (1) 2x8 at 16'' o.c. Douglas Fir #2 Douglas Fir #2 Trus Joist Boise Cascade Louisiana-Pacific RedBuilt Adequate Adequate Adequate Adequate Adequate 11 7/8" TJI 110 11 7/8" BCI 5000 1.7 11 7/8" LPI 18 11 7/8" Red-I45 11 7/8" RFPI 20 A B C D E Wood Joist ASD design per NDS 2015 A B C D E 2910 ft-lbs 11 7/8" TJI 210 11 7/8" BCI 6000 1.8 11 7/8" LPI 36 11 7/8" Red-I45 11 7/8" RFPI 40S F Roseburg Adequate Adequate Adequate Adequate Adequate Douglas Fir #2 Trus Joist Boise Cascade Louisiana-Pacific RedBuilt 329 ft-lbs Adequate F Roseburg Adequate 22 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Mark:B101 DL(psf) LL(psf) trib(ft) LL w(plf) TL w(plf) RDL = 380 lbs Span (ft) =4.0 roof 15 125 6 750 840 RLL = 1500 lbs lu (ft) =2.0 floor 0 0 0 0 0 RTL (left)=1880 lbs LL Deflection < L /360 wall 10 0 10 0 100 Total Deflection < L /240 misc.0 0 0 0 0 RDL = 380 lbs CD =1.00 750 plf 940 plf RLL = 1500 lbs Roof Snow Load ? :Yes DL(lbs) LL(lbs) x(ft)RTL (right) =1880 lbs Pt. Load 0 0 0 Reduce Floor LL ? :No Pt. Load 0 0 0 Mmax = B C D (2)2x8 (2)1.75x5.5 Wood Species = Fv (psi) =180 psi 265 psi 265 psi 265 psi 285 psi fv-max @ d (psi) =90 psi 50% 113 psi 43% 50 psi 19% 22 psi 8% 113 psi 40% Fb =1077 psi 2392 psi 2396 psi 2399 psi 2884 psi fb-max (psi) =858 psi 80% 1203 psi 50% 470 psi 20% 191 psi 8% 1278 psi 44% E (psi) = LL deflection =0.03'' 21% 0.04'' 32% 0.01'' 10% 0.00'' 3% 0.04'' 33% TL deflection =0.04'' 18% 0.05'' 27% 0.02'' 8% 0.01'' 3% 0.06'' 28% camber (in) =n/a 1/8''std=0.01''1/8''std=0.01''1/8''std=0.01''n/a Adequate Adequate Adequate Adequate Adequate Selection (A - E):A Use: (2) Mark:B102 DL(psf) LL(psf) trib(ft) LL w(plf) TL w(plf) RDL = 203 lbs Span (ft) =4.5 roof 15 100 6 600 690 RLL = 1350 lbs lu (ft) =2.0 floor 0 0 0 0 0 RTL (left)=1553 lbs LL Deflection < L /360 wall 0 0 0 0 0 Total Deflection < L /240 misc.0 0 0 0 0 RDL = 203 lbs CD =1.00 600 plf 690 plf RLL = 1350 lbs Roof Snow Load ? :Yes DL(lbs) LL(lbs) x(ft)RTL (right) =1553 lbs Pt. Load 0 0 0 Reduce Floor LL ? :No Pt. Load 0 0 0 Mmax = B C D (2)2x8 (2)1.75x5.5 Wood Species = Fv (psi) =180 psi 265 psi 265 psi 265 psi 285 psi fv-max @ d (psi) =78 psi 44% 97 psi 36% 44 psi 17% 20 psi 7% 96 psi 34% Fb =1077 psi 2392 psi 2396 psi 2399 psi 2884 psi fb (psi) =797 psi 74% 1118 psi 47% 436 psi 18% 177 psi 7% 1188 psi 41% E (psi) = LL deflection =0.04'' 24% 0.05'' 36% 0.02'' 11% 0.01'' 4% 0.06'' 38% TL deflection =0.04'' 19% 0.06'' 28% 0.02'' 9% 0.01'' 3% 0.07'' 29% camber (in) =n/a 1/8''std=0.01''1/8''std=0.01''1/8''std=0.01''n/a Adequate Adequate Adequate Adequate Adequate Selection (A - E):A Use: (2) 1747 ft-lbs B102 2x8 E 2000000 psi SCL: 26F 2.0E LVL 8.75x9 GLB Douglas Fir #2 Douglas Fir #2 24F-V4 B101 2x8 A 1800000 psi 1800000 psi 24F-V4 5.125x7.5 GLB3.125x6 GLB 24F-V4 1600000 psi 1800000 psi Douglas Fir #2 ASD design per NDS 2015 Wood Beam / Header EA 1880 ft-lbs 1600000 psi 1800000 psi 1800000 psi SCL: 26F 2.0E LVL24F-V4 1800000 psi 2000000 psi 3.125x6 GLB 5.125x7.5 GLB 8.75x9 GLB Douglas Fir #2 24F-V4 24F-V4 23 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Location: Plate Height (ft) =8.0 Stud Height (ft) = 7.6 Gravity Loads to Wall: Le/d = 26.1 < 50 OK DL(psf) trib(ft) w e(in) deflection < L/240 roof snow 0 0 0 0 wind/seismic (W/S)W floor live load 15 6 840 0 wind load, w (psf) =12 (Due to Wind)wall weight 10 10 100 0.6 * w = (psf) 7.2 misc. live load 0 0 0 0 snow load? (Y/N)Y w (total uniform load) = 940 plf Lumber Grade: (DF No. 2) fire rated assembly? (Y/N)N Load Cases: CD =1.60 CD =1.60 CD =1.00 P (lbs) = 253 per stud P (lbs) = 750 P (lbs) = 1253 per stud M (lb-ft) = 70 M (lb-ft) = 52 M (lb-ft) = 0 FcE (psi) =698 FcE (psi) =698 FcE (psi) =698 Fc' (psi) = 651 Fc' (psi) = 651 Fc' (psi) = 616 fc (psi) = 48 < Fc'OK fc (psi) = 143 < Fc'OK fc (psi) = 239 < Fc'OK Fb' (psi) = 2484 Fb' (psi) = 2484 Fb' (psi) = 1553 fb (psi) = 273 < Fb'OK fb (psi) = 205 < Fb'OK fb (psi) = 0 < Fb'OK CSR = 0.12 < 1.0 OK CSR = 0.15 < 1.0 OK CSR = 0.15 < 1.0 OK D (in.) =0.06 = L/1535 OK D (in.) =0.04 = L/2046 OK D (in.) =0.00 = L/5000 OK USE:2 x 4 Framing at Openings: Trimmers:King Studs: Trimmer supports only vertical load ... King stud supports only bending ... Pcap (lbs) = 3236 (axial compression governs)Mcap (lb-ft) = 551 Rcap (lbs) = 3281 trib width capacity (ft) = #### for M < Mcap trib width capacity (ft) = 8.53 for D < L /240 (governs) Wood Stud Wall Design Design based on NDS 2015 Trimmer Studs (TS) King Studs (KS) at 16'' o.c. D + LL Open Width (ft) Typical 8'-0" Plate 0 LL(psf) D + 0.6*W D + 0.75*(0.6*W + S + LL) 0 125 1 1 215'-8'' to 32'-9'' < 15'-8'' 49'-9'' to 66'-10'' 10 3 1 1 4 5 3 11 1 1 832'-9'' to 49'-9'' 1 1 (DF No. 2)Typical 8'-0" Plate 24 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Wood Posts/Studs Design based on NDS 2015 Wood Species: Douglas-Fir Axial Load Capacities (Kips) (Load Duration = 1.15 Snow )Post Height (ft) Post Size Bearing 8 10 11 12 14 16 18 20 * 2x4 DF stud 3.28 2.50 1.71 1.44 1.23 0.92 - - - * 2x4 DF#2 3.28 3.04 2.02 1.69 1.43 1.06 - - - 4x4 DF#2 7.66 7.08 4.71 3.93 3.33 2.47 - - - * 2x6 DF#2 5.16 9.30 6.92 5.96 5.15 3.91 3.06 2.45 2.00 4x6 DF#2, 2x4 wall 12.03 11.07 7.38 6.17 5.22 3.88 - - - 4x6 DF#2, 2x6 wall 12.03 21.70 16.16 13.90 12.01 9.13 7.14 5.71 4.67 6x6 DF#2 18.91 20.00 16.89 15.22 13.60 10.80 8.64 7.01 5.78 6x8 DF#1 25.78 32.82 25.96 22.76 19.93 15.41 12.15 9.77 8.01 6x10 DF#1 32.66 41.58 32.88 28.83 25.25 19.52 15.39 12.38 10.15 8x8 DF#2 35.16 41.50 38.77 37.01 35.03 30.58 26.08 22.03 18.62 * assumes post is continuously braced in weak direction. (Load Duration = 1.00 Floor)Post Height (ft) Post Size Bearing 8 10 11 12 14 16 18 20 * 2x4 DF stud 3.28 2.41 1.68 1.42 1.22 0.91 - - - * 2x4 DF#2 3.28 2.98 2.00 1.67 1.42 1.05 - - - 4x4 DF#2 7.66 6.96 4.67 3.90 3.31 2.46 - - - * 2x6 DF#2 5.16 8.68 6.67 5.79 5.04 3.86 3.03 2.43 1.99 4x6 DF#2, 2x4 wall 12.03 10.87 7.31 6.12 5.19 3.86 - - - 4x6 DF#2, 2x6 wall 12.03 20.26 15.56 13.51 11.75 9.01 7.07 5.67 4.64 6x6 DF#2 18.91 17.99 15.66 14.32 12.96 10.47 8.46 6.91 5.72 6x8 DF#1 25.78 30.05 24.58 21.83 19.30 15.10 11.98 9.68 7.95 6x10 DF#1 32.66 38.06 31.13 27.65 24.44 19.13 15.18 12.26 10.07 8x8 DF#2 35.16 36.59 34.61 33.34 31.87 28.46 24.76 21.23 18.13 * assumes post is continuously braced in weak direction. 206_Wood Post 25 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Key Plan Area =1 Risk Category =II Geotech Report Done? :No Site Class =D Seismic Design Category =D [per ASCE 7-16 tables 11.6-1 and 11.6-2] Importance Factor IE =1.00 [see ASCE 7-16 table 1.5-2] Seismic Force Resisting System (Table 12.2-1) = Structural System Height Limits (ft):65 Response Modification Coefficient, R =6.5 Overstrength factor, Ωο =3 Deflection Amplification Factor, Cd =4 Design Spectral Response Accelerations: Ss =36.6%S1 =14.3%[per ATC Hazard by Location Website] Fa = 1.51 Fv = 2.31 [per ASCE 7-16 table 11.4-1 & 11.4-2] SMS =0.552g SM1 =0.331g [ASCE 7-16 equation 11.4-1 & 11.4-2] SDS = 0.368g SD1 =0.221g [ASCE 7-16 equation 11.4-3 & 11.4-4] TL =6 CS =0.057 T = 0.104 T0 =0.120 Ct =0.020 Cs-max =0.327 Ta =0.104 TS =0.600 x =0.750 Cs-min =0.016 Tmax =0.145 Sa =0.338 CS (controls)=0.057 CU =1.4 k = 1.00 Main Seismic Force Resisting System: V = CsW =1.6 [per ASCE 7-16 equation 12.8-1] Vertical Distribution of Main Seismic Force Resisting System [per ASCE 7-16 section 12.8.3] Level hx (ft) wx (kip)wx hx k (kip-ft)Cvx Fx (kip) Vx (kip) Roof 9 28.0 252 1.000 1.6 1.6 Totals: 28 252 1.0 1.6 Transverse Diaphragm Design Forces [per ASCE 7-16 section 12.10.1.1] Level hx (ft) wpx (kip) ∑wi (kip) ∑Fi (kip) Fpx (min) (kip) Fpx (max) (kip) Fpx (kip) Roof 9 24.0 24.0 1.4 1.8 3.5 1.8 Longitudinal Diaphragm Design Forces [per ASCE 7-16 section 12.10.1.1] Level hx (ft) wpx (kip) ∑wi (kip) ∑Fi (kip) Fpx (min) (kip) Fpx (max) (kip) Fpx (kip) Roof 9 24.0 24.0 1.4 1.8 3.5 1.8 Design Seismic Lateral Loads Equivalent Lateral Force Procedure per Chapters 11 and 12 of ASCE 7-16 [ASCE 7-16 table 1.5-1] A.Light-frame (wood) walls sheathed with wood structural panels rated for shear resistance 26 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Shear Line :1 VSEISMIC =1,250 lbs SDS = 0.368g E = 0.70 x V = 875 lbs S.D.C. =D WWIND =0 lbs F = 0.60 x W = 0 lbs wall segments:1 2 3 4 5 6 Roof DL (psf) =0 length (ft)10.0 Floor DL (psf) =15 height (ft)8.0 Wall DL (psf) =10 roof trib. (ft)2.0 floor trib. (ft)0.0 Distance from HD to End of Wall (in)0 Stud Wall Thickness (in)6 Shearwall Anchored Into:Concrete aspect ratio 0.8 aspect ratio factor 2w/l 1.00 Seismic F (lbs)875 shear (plf)88 allowable shear (plf)156 suggested shearwall type 4 Mot (ft-lbs)7000 DL factor A =1.05 A x wDL (plf)84 End Post Compression(lbs)964 DL factor B 0.55 B x wDL (plf)44 End Post Uplift for Anchor Holdowns (lbs)neglect End Post Uplift for Straps (lbs)neglect Wind F (lbs)0 shear (plf)0 allowable shear (plf)218 suggested shearwall type 4 Mot (ft-lbs)0 wDL (plf)80 End Post Compression(lbs)243 DL factor C 0.60 C x wDL (plf)48 End Post Uplift for Anchor Holdowns (lbs)0 End Post Uplift for Straps (lbs)0 Maximum End Post Compression (lbs)964 Recommended Minimum End Post for Compression (2) 2x6 Controlling Anchor Holdown Uplift (lbs)0 Recommended Anchor Holdown Anchor at Midwall Anchor at Corner Anchor at Endwall Controlling Strap Holdown Uplift (lbs)0 Recommended Strap Holdown at Midwall Recommended Strap Holdown at Corner Recommended Strap Holdown at Endwall Line 1, Use:SW4 Wood Stud Shear Walls 2015 INTERNATIONAL BUILDING CODE (IBC) Wood Framing: Douglas-Fir OR Southern Pine 27 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Shear Line :A VSEISMIC =1,250 lbs SDS = 0.368g E = 0.70 x V = 875 lbs S.D.C. =D WWIND =0 lbs F = 0.60 x W = 0 lbs wall segments:1 2 3 4 5 6 Roof DL (psf) =0 length (ft)7.5 Floor DL (psf) =15 height (ft)8.0 Wall DL (psf) =10 roof trib. (ft)0.0 floor trib. (ft)6.0 Distance from HD to End of Wall (in)0 Stud Wall Thickness (in)6 Shearwall Anchored Into:Concrete aspect ratio 1.1 aspect ratio factor 2w/l 1.00 Seismic F (lbs)875 shear (plf)117 allowable shear (plf)156 suggested shearwall type 4 Mot (ft-lbs)7000 DL factor A =1.05 A x wDL (plf)179 End Post Compression(lbs)1495 DL factor B 0.55 B x wDL (plf)93 End Post Uplift for Anchor Holdowns (lbs)neglect End Post Uplift for Straps (lbs)neglect Wind F (lbs)0 shear (plf)0 allowable shear (plf)218 suggested shearwall type 4 Mot (ft-lbs)0 wDL (plf)170 End Post Compression(lbs)519 DL factor C 0.60 C x wDL (plf)102 End Post Uplift for Anchor Holdowns (lbs)0 End Post Uplift for Straps (lbs)0 Maximum End Post Compression (lbs)1495 Recommended Minimum End Post for Compression (2) 2x6 Controlling Anchor Holdown Uplift (lbs)0 Recommended Anchor Holdown Anchor at Midwall Anchor at Corner Anchor at Endwall Controlling Strap Holdown Uplift (lbs)0 Recommended Strap Holdown at Midwall Recommended Strap Holdown at Corner Recommended Strap Holdown at Endwall Line A SW4 Wood Stud Shear Walls 2015 INTERNATIONAL BUILDING CODE (IBC) Wood Framing: Douglas-Fir OR Southern Pine 28 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Location : Ultimate Seismic Load, w s (plf) =50 M@x (ft-lb) = 5,600 Seismic Load, w s(ASD) (plf) =35 T@x = C@x (lb) =467 Ultimate Wind Load, w w (plf) =25 # of Nails Req. at Splice, n = 3 Wind Load, w w(ASD) (plf) =15 V@x (lb) =-70 Length, L (ft) =36 vs@x (plf) =-6 Width, W (ft) =12 Mmax (ft-lb) = 5,670 Point of Interest, x (ft) =20 Tmax = Cmax (lb) =473 OK Case :1 Allowable Chord Tension Load = 9867 Chord Member :# of Nails Req. at Splice, n =3 Chord Splice Nail :Rmax (lb) =630 vmax (plf) =53 20 Unblocked Allowable, v s (plf) =285 OK # of Chord Splices =4 Blocked Allowable, v s (plf) =N/A Allowable Diaphragm Deflection, L /240 Width of Blocking Req'd (ft) =N/A Wood Species :Diaphragm Deflection, (in) =0.39 Structural 1 Sheathing? :No Allowable Deflection, (in) =1.80 OK Sheathing Thickness :19/32 Sheathing Type :OSB Ga (kips/in) =13 M@x (ft-lb) = 2,400 Nail Size :10d T@x = C@x (lb) =200 Adjoining Panel Edges :2x # of Nails Req. at Splice, n = 2 ASD Reduction Factor = 2.0 V@x (lb) =-30 Aspect Ratio = 3.00 OK vs@x (plf) =-3 Block Entire Diaphragm :No Mmax (ft-lb) = 2,430 Nail Spacing Tmax = Cmax (lb) =203 OK Boundaries (in) =6 Allowable Chord Tension Load = 9,867 Edges (in) = 6 # of Nails Req. at Splice, n =2 Rmax (lb) =270 vmax (plf) =23 Unblocked Allowable, v w (plf) =400 OK Blocked Allowable, v w (plf) =N/A Width of Blocking Req'd (ft) =N/A Diaphragm Deflection, (in) =0.17 Allowable Deflection, (in) =1.80 OK Use: 0.59375'' thick sheathing, unblocked, attach with 10d nails at 6'' o.c. at panel edges and 6'' o.c. at boundaries. Seismic Diaphragm Parameters Wind Wood Structural Panel Horizontal Diaphragm ANSI / AF&PA SDPWS-2008 Distance from chord splice to nearest support, x (ft) = 16d Box 2-2x6 Longitudinal Douglas Fir #2 29 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop Continuous Concrete Wall Footings Strength Design per ACI 318-11 Mark:Allowable q (psf) =1500 U = 1.2DL + 1.6LL Code Increases (Y/N) =N DL LL trib(ft) P DL (k/ft)P LL (k/ft)Pu (k/ft) roof 15 125 6 0.09 0.75 1.31 floor 0 0 0 0.00 0.00 0.00 wall 10 0 20 0.20 0.00 0.24 misc.0 0 0 0.00 0.00 0.00 Total(k/ft) =0.29 0.75 1.55 Footing Dimensions Width (in) =16 Adjusted q (psf) = 1500 stemwall width(in) =8 Thickness (in) =8 Allowable qu (psf) = 2232.692 stemwall height(in) =24 qmax (psf) =1161 OK Pmax (kips) =11.7 Footing Type: Strip(S) or Turndown Edge(T) or Monolithic w/Slab(M) =S unfactored Continuous Reinforcing Rebar Size =#4 Check p Other Parameters area of bar(in^2) = 0.20 Min p =0.0018 fy (psi) = 60000 bar diameter(in) = 0.50 Max p =0.0134 f'c (psi) =2500 Total Bars = 2 Use p =0.0018 B1 =0.85 As req(in^2)= 0.2304 Reinforcement Top and Bottom(Y/N) =N Transverse Reinforcing Not Required Rebar Size =#4 Check p Check Development Length area of bar(in^2) = 0.20 L' (ft) = 0.33 p =0.0000 fy (psi) = 60000 bar diameter(in) = 0.50 Mu (k-ft) = 0.03 Min p =0.0001 Ld1 (in) =24.0 Spacing (in) = 1313 d (in)= 4.25 Max p =0.0134 Ld2 (in) =12 As req(in^2/ft)= 0.00 Use p =0.0001 Ld3 (in) =12 Less than pmax, OK Available Ld (in) = 13.3 F16 Use: 16'' wide x 8'' thick Continuous Concrete Footing w/ 2 #4 Continuous Max. Point Load: F16 30 of 30 FROST Structural Engineering Project Name:Project No. : Eng. : Date : Sheet : DBP FSE11/03/21IF21-411Rocky Mountain Power Mechanics Shop