Loading...
HomeMy WebLinkAboutPLANS - 23-00035 - BYUI Benson Floral Lab - Remodel8270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:24 AMELECTRICALSYMBOLS &DETAILSFLORAL LABREMODELE000CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYFELECTRICAL SYMBOL SCHEDULENOTE: ALL SYMBOLS MAY NOT BE USEDSYMBOLDESCRIPTION'LA'ELECTRICAL PANELBOARD, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION)JJUNCTION BOXPOWER AND/OR DATA SERVICE POLEPUSHBUTTON STATIONCEILING MOUNTED DUPLEX RECEPTACLE DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FTGFCI-TYPE DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FTDOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FTGFCI-TYPE DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT.RECEPTACLE AND EQUIPMENT SUBSCRIPTSACABOVE COUNTERWPWEATHERPROOF (UL LISTED WEATHER-RESISTANT)HVAC THERMOSTAT OR SENSOR; PROVIDE & INSTALL BACKBOX,3/4" CONDUIT AND CONDUCTORS TO ASSOCIATED HVAC UNIT. COORDINATE EXACT LOCATION & SIZE AND NUMBER OF CONDUCTORS WITH M.C. TSORSMALL EXHAUST FAN CONNECTION42" MOUNTING HEIGHT AFF OR AFGUSB120V RECPT. W/ USB CHARGING PORTSGENERAL SPECIAL SYSTEM NOTES:A. ALL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES AS NECESSARY IN ORDER TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN TILEWORK/WALL OR WAINSCOATING, ETC. B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL A GFCI TYPE RECEPTACLE FOR ALL RECPTACLES SHOWN IN TOILET RMS, BATHROOMS, KITCHENS/SERVING AREAS, ROOFTOP, OUTDOORS OR WITHIN 6FT OF ANY SINK, BASIN, TUB OR FLOOR SINK AND ALL OTHER AREAS DEFINED BY THE NEC.2X4 LED FIXTURE2X2 LED FIXTURESURFACE MOUNTED LED FIXTURELIGHT FIXTURE SUBSCRIPTSNL NIGHT-LIGHT(CONNECT TO UNSWITCHED LEG OF CIRCUIT)SHADED FIXTURE INDICATES AN EMERGENCY FIXTURE. CONNECT TO EMERGENCY POWER SYSTEM. PROVIDE WITH TEST LIGHT AND SWITCH. CEILING MOUNTED OCCUPANCY SENSOR, REFER TO OCCUPANCY SENSOR/SWITCHSCHEDULE FOR SENSOR TYPE AND ADDITIONAL INFORMATION.SWITCH MOUNTED OCCUPANCY SENSOR, LOW VOLTAGE SWITCHPOD OR DIMMER SWITCH, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR TYPE AND ADDITIONAL INFORMATION.SINGLE-POLE SWITCH SWITCH SUBSCRIPTSD DIMMER SWITCH (COMPATIBLE W/ LOAD & LTG TYPES)F TIMER SWITCH (INTERMATIC MODEL EI400 SERIES)WP WEATHERPROOFF1LIGHT FIXTURE TYPE DESIGNATIONS###GENERAL LIGHTING NOTES:A. SYMBOLS SHOWN ABOVE MAY NOT REPRESENT ALL LIGHT FIXTURES USED ON PROJECT, REFER TO LIGHT FIXTURE SCHEDULE FOR ACTUAL FIXTURE INFORMATION INCLUDING FIXTURE TYPE, LAMPING, MOUNTING AND ETC.B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING".C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS; E.C. SHALL PROVIDE AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROL SCHEMES INDICATED AND DESCRIBED ON DRAWINGS. INCLUDING ALL 0 - 10V DIMMING CONTROLS BETWEEN SWITCH AND FIXTURES.D. ALL BATTERY EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA.###SYMBOLDESCRIPTIONWALL MOUNTED FIRE ALARM SPEAKER ONLYWALL MOUNTED FIRE ALARM STROBE ONLY(CANDELA RATING AS INDICATED)####CEILING MOUNTED FIRE ALARM STROBE ONLY (CANDELA RATING AS INDICATED)####WALL MOUNTED FIRE ALARM SPEAKER STROBE (CANDELA RATING AS INDICATED)CEILING MOUNTED FIRE ALARM SPEAKER STROBE (CANDELA RATING AS INDICATED)A. DO NOT INSTALL MORE THAN (10) NOTIFICATION APPLIANCES ON ANY SINGLE CLASS "A" SIGNAL CIRCUIT. DO NOT EXCEED 400 FT. OF NO. 14 WIRE IN THE TOTAL LOOP.B. NFPA ALLOWS NOTIFICATION APPLIANCES TO BE MOUNTED AT A HEIGHT RANGE BETWEEN 80" TO 96" ABOVE FINISH FLOOR. THE PREFERRED HEIGHT IS 80". IF THIS CONFLICTS WITH OTHER TRADES OR ROOM FURNISHINGS, LOCATE AS CLOSE TO 80" AS POSSIBLE, NOT EXCEEDING 96". ALL NOTIFICATION APPLIANCES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE LOCATED AT A COMMON HEIGHT.C. MOUNT PULL STATIONS AT 46-48" A.F.F. TO THE OPERATING HANDLE TO MEET ADA REQUIREMENTS.D. DO NOT CONNECT THE FIRE ALARM SYSTEM TO ANY DEVICE WHICH HAS A POWER HELD CONTACTS.(FLOW, TAMPER, HOOD SYSTEM, DUCT DETECTOR, ETC..FALSE ALARM WILL OCCUR.E. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL CONDUCTOR QUANTITIES PER FIRE ALARM SYSTEM SUPPLIER, AND AS PER NFPA AND NEC REQUIREMENTS.F. DO NOT INSTALL ANY SMOKE OR HEAT DETECTORS WITHIN 3 FEET OF ANY AIR DIFFUSER.G. DO NOT EXCEED 2500 FEET ON ANY ADDRESSABLE DEVICE RUN. DO NOT EXCEED 120 DEVICES ON ANY ONE ADDRESSABLE DEVICE RUN.H. ALL AIR HANDLING EQUIPMENT 2000 CFM OR MORE MUST BE SHUT DOWN UPON FIRE ALARM AS PER LIFE SAFETY CODES.I. ALL CLASS "B" INITIATING CIRCUITS WITH ADDRESSABLE DEVICES NEED EOLR. (END OF LINE RESISTORS).J. IN CORRIDORS, NOTIFICATION APPLIANCES MUST BE LOCATED WITHIN 15' FROM ENDS OF CORRIDORS AND A MAXIMUM OF 100' SPACING.K. NOTIFICATION APPLIANCES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3 TEMPORAL PATTERN.L. ALL WIRING AND CONDUIT ROUTING TO BE AS DESCRIBED ON SUPPLIED SHOP DRAWINGS. FIRE ALARM PLAN IS SHOWN FOR GENERAL LOCATION AND LAYOUT ONLY.M. THE FIRE ALARM SYSTEM TO BE IN COMPLIANCE WITH ALL APPLICABLE LOCAL, STATE AND ADA REQUIREMENTS.N. ELECT. CONTR. TO CONNECT SPRINKLER SYSTEM TAMPER SWITCHES AND FLOW VALVES TO FIRE ALARM SYSTEM AS REQUIRED. SEE FIRE SPRINKLER SYSTEM DRAWINGS FOR EXACT LOCATIONS AND QUANTITIES.GENERAL FIRE ALARM SYSTEM NOTESDATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)_D-XCEILING MOUNTED DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)_D-XA. COMMUNICATIONS CABLES SHALL HAVE BENDS NO GREATER THAN 90 DEG.B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND RADIUS NOT MORE THAN 10X THE DIAMETER OF THE CONDUIT.C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING AT BOTH ENDS.D. COMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN (2) 90'S WITHOUT A PULLBOX. PULL BOXES SHALL BE LOCATED IN ACCESSIBLE LOCATIONS AND SHALL BE SIZED AT LEASED 12X THE LARGEST CONDUIT DIAMETER IN LENGTH AND MIN, 4" DEEP AND 8" WIDE.E. IT SHALL BE THE RESPONSIBILITY OF THE E.C. TO INSURE THAT THE PATHWAY FOR THE DATA CABLING DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCH PANEL, THIS INCLUDES SERVICE LOOPS AND PATCH CORDS. F. WHERE CABLE TRAY IS UTILIZED IN THE PROJECT. COMMUNICATION CONDUITS ENDING AT THE CABLE TRAY SHALL EXTEND 1" OVER THE SIDE INTO THE TRAY. GENERAL SPECIAL SYSTEM NOTES:SPECIAL SYSTEMS NOTES:1. UTILIZE 4 11/16" DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR DATA RACK, TERMINATE WITH INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES INDICATED FROM OUTLET TO NEAREST TELE/DATA ROOM. SEE DWGS FOR ADDITIONAL INFORMATION. UTILIZE J-HOOKS 3FT ON CENTER FOR SUPPORT OF CABLING WHERE CABLE TRAY IS NOT INSTALLED/SPECIFIED.2. CONDUIT SIZE ('X' FROM ABOVE); 2=1/2", 3=3/4", 4=1", 5=1-1/4", 6=1-1/2"3. BLANK (NO LABEL) = 4-11/16" DEEP BOX WITH REQUIRED MUDRING AND 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING/CABLE TRAY, TERMINATE WITH INSULATED THROAT BUSHING, PROVIDE PULL STRING. (UNLESS OTHERWISE NOTED)SYMBOLDESCRIPTIONSYMBOLDESCRIPTION 8270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:24 AMGENERAL NOTES &DETAILSFLORAL LABREMODELE001CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYA. E.C. SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS.B. E.C. SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS. SEE ELECTRICAL EQUIPMENT CLEARANCE DETAIL.C. INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE. ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED.D. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S) FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC.E. E.C. SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED FOR ALL ELECTRICAL EQUIPMENT.F. CONFIRM EXACT LOCATIONS OF ALL TELEPHONE/DATA OUTLETS WITH OWNER PRIOR TO ROUGH-IN.G. LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT RO INTERFERE WITH ROOM CABINETS, ETC.H. SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING.I. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR WORK AND PAY ASSOCIATED FEES.J. MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLING AND ELECTRONIC BALLASTS.K. UNLESS SPECIFICALLY INDICATED OTHERWISE, E.C. SHALL COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER/SHOP DRAWINGS; DENTAL, MEDICAL, KITCHEN, SPECIALIZED EQUIPMENT, ETC. FOR THE EXACT ROUGH-IN REQUIREMENTS FOR THEIR EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE E.C. TO BE RESPONSIBLE FOR FINAL ELECTRICAL CONNECTIONS TO ALL SPECIAL EQUIPMENT.L. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION.M. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. N. DATA CABLING SYSTEM PRE-INSTALLATION CONFERENCE: E.C. SHALL SCHEDULE A MEETING A MINIMUM OF FIVE CALENDAR DAYS PRIOR TO BEGINNING DATA CABLING INSTALLATION . ATTENDEES SHOULD INCLUDE OWNER’S REP., ENGINEER, GC, EC AND CABLING SUB. REFER TO SECTION 26 6210(1.4)(E) FOR ADDITIONAL INFORMATION.PROJECT GENERAL NOTES:TYPICAL DEVICE MOUNTING HEIGHTS:FINISH FLOOR1' - 6''THERMOSTAT OR SENSORVERIFY WITH M.C. PRIOR TOLIGHT SW.(OR AS NOTED)* 4' - 0''* 3' - 6''(OR AS NOTED)RECEPTACLE@ MILLWORKBACKSPLASHCAB. DIMENSIONSPER ARCH. DETAIL6"CABINETROUGH-IN.TYPICAL FOR ALL DEVICESMOUNTED ABOVE COUNTER(ie C.O.'S, DATA, PHONE etc.)FIRE6' - 8''FIRE ALARM NOTIFICATIONDEVICEFIREMANUAL PULL STATIONHANDLE SHALL BEBETWEEN 42" & 48" AFFCABINETRECEPT.TELE/DATAOUTLETTVOUTLETGENERAL DETAIL NOTES:A. ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE.B. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC.C. ALL SWITCHES AND THERMOSTATS TO BE MOUNTED AS CLOSE TO DOOR JAMS AS POSSIBLE. COORDINATE ALL DEVICES WITH ARCHITECTURAL PLANS AND DETAILS.D. COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINSCOTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES.GENERAL COORDINATION NOTE:• E.C. SHALL COORDINATE ALL DEVICE MOUNTING HGTS. AND EXACT LOCATION WITH ARCHITECTURAL INTERIOR ELEVATIONS REPORT CONFLICTS TO ARCHITECT **PRIOR TO ROUGH-IN** 8270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:25 AMSCHEDULESFLORAL LABREMODELE002CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYLIGHTING FIXTURE SCHEDULETYPE DESCRIPTION MOUNTING VOLTAGE LUMENSCOLORTEMP.(K) MFGR. CATALOG # NOTESF1 EXISTING 2X2 LAY-IN FIXTURE RECESSED 120-277EXISTING CLASSROOM LIGHTF2 2X2 LAY-IN LED, 0-10V DIMMING, TOMATCH EXISTING FIXTURESRECESSED 120-277 4000 4000 LITHONIA EPANL-2X2-4800LM-80CRI-40K-MIN1-NLIGHT-MVOLT1. REFER TO DRAWINGS FOR FIXTURES REQUIRED TO HAVE 0-10V OR STEP-LEVEL DIMMING CONTROL. PROVIDE FIXTURE(S) WITH LED DRIVER(S) AND REQUIRED DIMMING/SWITCH-LEG CONDUCTORS BETWEEN SWITCH(ES) AND FIXTURE(S) TO PROVIDE CONTROL AS INDICATED ON DRAWINGS.2. CBA - STANDARD COLOR BY ARCHITECT/OWNER (COORDINATE COLOR WITH ARCHITECT/OWNER PRIOR TO ORDERING.)3. PROVIDE ALL COMPONENTS FOR COMPLETE INSTALLATION, INCLUDING BUT NOT LIMITED TO: END FEEDS, CONNECTORS AND ETC. LIGHT FIXTURE SCHEDULE NOTES:• LIGHTING FIXTURES INDICATED IN SCHEDULE ARE BASIS OF DESIGN, ALTERNATE MANUFACTURERS SHALL BE PRE-APPROVED BY ADDENDUM. ALTERNATE MANUFACTURERS SHALL SUBMIT PER-APPROVALS TO ENGINEER A MINIMUM OF 10 DAYS PRIOR TO PROJECT BID DATE. • EXISTING FIXTURES TO BE CAREFULLY REMOVED, CLEANED, AND STORED IN PREPARATION FOR REINSTALLATION IN NEW LOCATION.GENERAL LIGHTING SCHEDULE NOTES:1. PROVIDE 0-10V DIMMING CONDUCTORS (GREY & VIOLET) BETWEEN DEVICE AND LIGHT FIXTURE(S) FOR DIMMING AS INDICATED ON DWGS.2. ROUTE ASSOCIATED ROOM LTG CIRCUIT THROUGH RELAY FOR CONTROL, PROVDE 0-10V DIMMING AND LOW VOLTAGE CONNECTIONS AS INDICATED ON DRAWINGS AND DETAILS.3. DEVICE COLOR SHALL MATCH WIRING DEVICES; REFER TO SPECIFICATIONS.4. MOUNT DEVICE TO BOTTOM OF STRUCTURE.nLIGHT LIGHTING CONTROL SCHEDULE NOTES:nLIGHT LIGHTING CONTROL SCHEDULE GENERAL NOTES:• E.C. SHALL BE RESPONSIBLE FOR PROVIDING ALL LIGHTING CONTROL COMMISSIONING/PROGRAMMING OF ALL nLIGHT COMPONENTS. THE COMMISSIONING/PROGRAMMING SHALL BE DONE BY A nLIGHT CERTIFIED TECHNICIAN. • E.C. SHALL NOTIFY OWNER 1-WEEK PRIOR TO COMMISSIONING/PROGRAMMING OF THE SYSTEM SO THAT THE OWNER CAN PROVIDE REPRESENTATIVES DURING THE COMMISSIONING/PROGRAMMING PERIOD.LIGHTING CONTROL (nLIGHT) SYSTEM SCHEDULETYPEDESCRIPTIONMFGR. CATALOG # NOTESCEILING SENSORSnD1 DUAL-TECHNOLOGY, SMALL MOTION, CEILING OCCUPANCY SENSOR W/ AUTO DIMMING CONTROL PHOTOCELL SENSOR SWITCH nCM-PDT-9-RJB-ADCXWALL SWITCHESn2D nLIGHT ON/OFF PUSHBUTTON W/DIMMING, 2-CHANNELSENSOR SWITCH nPODM-2PDX-X 3nD nLIGHT ON/OFF PUSHBUTTON W/DIMMINGSENSOR SWITCH nPODM-DX 3nDC nLIGHT ON/OFF PUSHBUTTON W/DIMMING, COLOR CORRECTIONSENSOR SWITCH nPODM-DX-CCT 3 COOLERFLORAL DESIGN CLASSROOM[154]FLORAL DESIGN STUDIO[147]FLORAL DESIGN LAB[150]NOT IN REMODEL8270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:25 AMEXISTING OVERALLFLOOR PLANFLORAL LABREMODELED100CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYSCALE: 3/32" = 1'-0"1EXISTING OVERALL FLOOR PLANNORTH16'8'0" n2D1TYP22344'BF'8270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:25 AMEXISTING RM 147FLORAL LABREMODELED101CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYKEY NOTES:#A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 CAREFULLY DISCONNECT, REMOVE,AND CLEAN EXISTING LIGHT FIXTURES.STORE IN PREPARATION TO BEREINSTALLED IN NEW CEILING.MAINTAIN AND PROTECT EXISTINGLIGHTING CIRCUIT TO BE USED DURINGREINSTALLATION.2 DISCONNECT AND REMOVE EXISTINGLIGHT FIXTURE. REMOVE ALLASSOCIATED CONTROLS, CONDUCTORS,AND CONDUIT. MAINTAIN AND/ORRE-ESTABLISH ELECTRICAL CONTINUITYTO DOWN STREAM DEVICES TO REMAIN.SCALE: 3/16" = 1'-0"1EXISTING RM 1473 DISCONNECT AND REMOVE EXISTINGLIGHT FIXTURE. REMOVE ALLASSOCIATED CONTROLS, CONDUCTORS,AND CONDUIT. MAINTAIN AND/ORRE-ESTABLISH ELECTRICAL CONTINUITYTO DOWN STREAM DEVICES TO REMAIN.4 DISCONNECT AND REMOVE EXISTINGDEVICE IN CONFLICT W/ REMODEL.REMOVE ALL ASSOCIATED CONDUITAND WIRE BACK TO NEXT ACTIVE J-BOXOR SOURCE.A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL EXISTING ELECTRICAL EQUIPMENT SHALL REMAIN.B. CONTRACTOR MUST MAINTAIN AND/OR RE-ESTABLISH ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN.C. PROVIDE ALL NEW DEVICES AND COVERSGENERAL NOTES:8'4'0"NORTH n2DnD1TYP28270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:25 AMEXISTING RM 150FLORAL LABREMODELED102CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYKEY NOTES:#A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 PROTECT AND MAINTAIN EXISTINGLIGHTING AND CONTROLS IN ROOM TOREMAIN. PROTECT AND/ORRE-ESTABLISH EXISTING ELECTRICALFEEDER AND CONTROL CONDUCTORS.2 DISCONNECT AND REMOVE EXISTINGDEVICE IN CONFLICT W/ REMODEL.REMOVE ALL ASSOCIATED CONDUIT ANDWIRE BACK TO NEXT ACTIVE J-BOX ORSOURCE.SCALE: 3/16" = 1'-0"1EXISTING RM 150A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL EXISTING ELECTRICAL EQUIPMENT SHALL REMAIN.B. CONTRACTOR MUST MAINTAIN AND/OR RE-ESTABLISH ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN.C. PROVIDE ALL NEW DEVICES AND COVERSGENERAL NOTES:8'4'0"NORTH SnD1SnD1nDn2DnD12222222228270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:25 AMEXISTING RM 154FLORAL LABREMODELED103CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYSCALE: 3/16" = 1'-0"1EXISTING RM 154KEY NOTES:#A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 PROTECT AND MAINTAIN EXISTINGLIGHTING AND CONTROLS IN ROOM TOREMAIN. PROTECT AND/ORRE-ESTABLISH EXISTING ELECTRICALFEEDER AND CONTROL CONDUCTORS.2 DISCONNECT AND REMOVE EXISTINGDEVICE IN CONFLICT W/ REMODEL.REMOVE ALL ASSOCIATED CONDUIT ANDWIRE BACK TO NEXT ACTIVE J-BOX ORSOURCE.A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL EXISTING ELECTRICAL EQUIPMENT SHALL REMAIN.B. CONTRACTOR MUST MAINTAIN AND/OR RE-ESTABLISH ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN.C. PROVIDE ALL NEW DEVICES AND COVERSGENERAL NOTES:8'4'0"NORTH COOLERFLORAL DESIGN CLASSROOMFLORAL DESIGN STUDIOFLORAL DESIGN LABNOT IN REMODELNEW STORAGENEW OFFICEFLORAL DESIGN LAB8270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:26 AMNEW OVERALLFLOOR PLANFLORAL LABREMODELEE100CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYSCALE: 3/32" = 1'-0"1OVERALL FLOOR PLAN16'8'0"NORTH n2Dn2DSnD1SnD1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F2F2F2F2F2F2F2F28270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:26 AMRM 147 LIGHTINGPLANFLORAL LABREMODELEE101CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYA. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:SCALE: 3/16" = 1'-0"1RM 147 LIGHTING PLAN8'4'0"NORTH FFLORALDESIGNSTUDIO[147]ACAC4D-412222'BF'AC6D-5238270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:26 AMRM 147 POWERPLANFLORAL LABREMODELEE102CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYKEY NOTES:#A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 SLIM-LINE AV SYSTEM CABINET.PROVIDE (2) DUPLEX OUTLETS INCABINET, EXTRA-DEEP BOX WITH 1 1/2"CONDUIT TO ABOVE ACCESSIBLECEILING FOR DATA/AV CABLING.COORDINATE EXACT PLACEMENT OFBOXES WITH CABINET AND KENDENJENSEN, CAMPUS AV, PRIOR TOROUGH-IN. PROVIDE A #10 GREENINSULATED GROUND CONDUCTOR FROMCABINET TO NEAREST ELECTRICALROOM GROUND BAR. FIELD VERIFYFINAL LOCATION PRIOR TO ROUGH-IN.SCALE: 3/16" = 1'-0"1RM 147 POWER PLAN2 CIRCUIT TO PANEL BF. PROVIDE ANDINSTALL NEW BREAKERS ASNECESSARY TO ACCOMMODATEDESIGN, PROVIDE AND INSTALL NEWPANEL SCHEDULE.3 RECEPTACLE FOR PAINT HOOD.COORDINATE RECEPTACLE LOCATIONWITH PAINT HOOD SHOP DRAWINGSPRIOR TO ROUGH IN. CONTROLRECEPTACLE WITH SWITCH.NORTH8'4'0" FLORALDESIGNLAB[151]ACACAC1AC8270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:26 AMRM 150 POWERPLANFLORAL LABREMODELEE103CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYKEY NOTES:#A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 CIRCUIT TO PANEL BF. PROVIDE ANDINSTALL NEW BREAKERS ASNECESSARY TO ACCOMMODATEDESIGN, PROVIDE AND INSTALL NEWPANEL SCHEDULE.SCALE: 3/16" = 1'-0"1RM 150 POWER PLAN8'4'0"NORTH WS-1SWS-1SACACACPROJ4D-41222222'CR''BR'6D-5338270STATEOFIDAHOTODDPAYNEREGISTEREDRPOFESSIONALENGINEEREngineering Inc.Consulting Engineers1823 E. CenterPocatello, Idaho 83201tel (208) 232-4439www.payneengineeringinc.comPROJECT NAME:SHEET NAME:SHEET NUMBER:DRAWN BY:CHECKED BY:REVISION SCHEDULEPROJECT NO: DOCUMENT STATUSSTATUS DATEDESCRIPTIONNO. DATE©2021 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460P.E.# 223512-19-202212/19/2022 11:55:27 AMRM 154 POWERPLANSFLORAL LABREMODELEE104CheckerAuthorProject NumberPHONE # (208) 496 2667ARCHITECT 'S EMAIL: gayf@byui.eduDAVID GAYKEY NOTES:#A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES:1 SLIM-LINE AV SYSTEM CABINET.PROVIDE (2) DUPLEX OUTLETS INCABINET, EXTRA-DEEP BOX WITH 1 1/2"CONDUIT TO ABOVE ACCESSIBLECEILING FOR DATA/AV CABLING.COORDINATE EXACT PLACEMENT OFBOXES WITH CABINET AND KENDENJENSEN, CAMPUS AV, PRIOR TOROUGH-IN. PROVIDE A #10 GREENINSULATED GROUND CONDUCTOR FROMCABINET TO NEAREST ELECTRICALROOM GROUND BAR. FIELD VERIFYFINAL LOCATION PRIOR TO ROUGH-IN.2 CIRCUIT TO PANEL CR. PROVIDE ANDINSTALL NEW BREAKERS ASNECESSARY TO ACCOMMODATEDESIGN, PROVIDE AND INSTALL NEWPANEL SCHEDULE.3 REPLACE EXISTING RECEPTACLE WITH AGFCI RECEPTACLE.SCALE: 3/16" = 1'-0"1RM 154 POWER PLAN8'4'0"NORTH