Loading...
HomeMy WebLinkAboutREV A - 21-00862 - 950 Green Haven Cir - Solar Panels 3049 Executive Way, Suite 200 Lehi UT 84043 cadrevisions@gosolo.io gosolo.io (888) 316-5845 Date: December 16, 2021 Customer Name: Matt Lindstrom Project Address: 950 Greenhaven St Rexburg ID 83440 Outlined below are the list of rejections received from the plan checking department. Each revision item has a response, outlining our corrective action for your rejection, these will be marked in red in this letter and will also have red revision clouds on the permit packet/plan set. If you have any questions, please reach out to the submitting entity/company, or in some cases, this may be Solo. 1) Need listing from accredited testing laboratory for the combiner box, disconnect and junction boxes. - Please see additional attached documents for listings. 2) Cannot use 90 degree column of 310.15B16 unless terminals are listed. 110.14C1 Please verify terminals or show as 30 amps. - Please see updated PV05. A note has been added stating, “Per NEC 110.14(C), Conductors with temperature ratings higher than specified for terminations shall be permitted to be used for ampacity adjustment, correction, or both. 3) Where a disconnect is considered a service, neutral and ground need to be bonded together and ground needs to go to grounding electrode. - Please see updated PV05. Fused AC disconnect neutral and ground have been bonded and connected to a grounding electrode. 814 E 1475 N Lehi, UT 84043 m: (309) 645-0999 Solar Professional Engineering Consulting 2021.10.13 admin@lucenteng.co Element Solar, LLC 2000 Ashton Blvd Suite #170 Lehi, UT 84043 RE: Engineering Services Lindstrom Residence 950 Greenhaven St, Rexburg, ID 17.6 kW System Solo Job #1578597 To Whom It May Concern, A. Assumptions from Field Observation provided by Element Solar, LLC Roof Roof B Roof Finish :Asphalt Shingle Asphalt Shingle Roof Underlayment :Plywood Plywood Roof Profile :Hip Gable Hip Gable Roof Structural System :Metal Plate Trusses Metal Plate Trusses Truss Top Chord/Setup :2 x 4 / Fink 2 x 4 / Fink Chord/Rafter Wood Grade :Spruce-Pine-Fir MSR 2100f-1.8E or betterSpruce-Pine-Fir MSR 2100f-1.8E or better Truss/Rafter Spacing :24'' o.c.24'' o.c. Roof Slope :32 deg 32 deg Max Top Chord/Rafter Span :9 ft 9 ft Bearing Wall Type :Convl Lt-Frame Constr CLFC Foundation :Permanent Concrete Permanent Concrete Stories :Two Single B. Building Design Criteria Code : 2018 IRC (ASCE 7-16)Risk Category : II Roof Live Load : 20 psf (0 psf at panels)Occupancy Class : R-3 Ground Snow Load : 50 psf Roof Dead Load : 6.3 psf Ult Wind Speed : 115 mph PV Dead Load : 3 psf Exposure Category : C Total Dead Load : 9.3 psf C. Summary of Existing Structure Results Roof - Adaquate to support the additional imposed loads. No structural upgrades are required. The following structural design regarding the proposed alterations have been prepared from these assumptions. The verification of the field observations is the responsibility of the contractor. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the sealed plans, calculations, and/or certification letter and notify the Engineer of Record of any discrepancies. After review of the field observations and based on our calculations and in accordance with the applicable building codes and current industry standards, the existing roof structure supporting the proposed alterations consisting of the solar array has been determined to be: Lucent Engineering, P.C. December 19, 2021 We have reviewed the following information regarding the solar panel installation for this project. Alterations to these documents or plans shall not be made without direct written consent of the Engineer of Record. D. Solar Panel Support Bracket Anchorage 1. 2.Manufacturer's Panel Bracket Connection to Roof Chord/Rafter Member: Fastener : (1) 5/16'' Lag Screw per Bracket NDS Withdrawl Value : 205 lbs/inch Min. Thread Length and Pentration Depth : 2.5'' 3. 4. E. Overall Summary Sincerely, John H. Leesman, PE License No. 14432 Limits of Scope of Work and Liablity Page 2 of 2 Lindstrom Residence The existing structure is assumed to have been designed and constructed following appropriate codes at the time of erection and assumed to have appropriated permits. The calculations performed are only for the roof framing supporting the solar array installation referenced in the stamped plans and were completed according to generally recognized structural analysis standards and procedures, professional engineering, and design experience opinions and judgements. Existing deficiencies which are unknown or were not observed during the time the site observation are not included in this scope of work. All solar panel modules, racking, and mounting equipment shall be designed and installed per the manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and/or certification letter and notify the Engineer of Record of any discrepancies prior to starting construction. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. The contactor shall also verify that there are no damage/deficiencies (i.e., dry rot, water damage, termite damage, framing member/connection damage, etc.) to framing that was not addressed in the stamped plans, calculations, and/or certification letter and notify the Engineer of Record of any concerns prior to starting construction. Lucent Engineering, P.C.December 19, 2021 Should you have any questions regarding this letter or if you require further information, do not hesitate to contact me. Considering the existing roof's slope, size, spacing, condition, and calculated loads, the panel bracket supports shall be placed no greater than 48 in. o/c. Panel supports connections shall be staggered to distribute load to adjacent trusses. Solar panels shall be designed, mounted, and installed in accordance with the most recent ''UniRac Installation Manual'', which can be found on the UniRac website (http://unirac.com/). Based on the information supplied to us at the time of this report, on the evaluation of the existing structure, and solar array panel bracket connection, it is our opinion that the roof system will adequately support the additional loads imposed by the solar array. This evaluation conforms to 2018 IRC and current industry standards. Rocky Mountain Power IDAHO PORTICADE CONSTRUCTION 2000 W. ASHTON BLVD SUITE #170 LEHI, UT 84043 LICENSE: #10744487-5501 CONTRACTOR INFORMATION: SITE INFORMATION Matt Lindstrom 950 Greenhaven St Rexburg, ID 83440 AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC Lat, 43.806738 Long, -111.779421 (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) DATE: December 16, 2021 PV01 COVER PAGE PV02 SITE PLAN PV03 ROOF ATTACHMENTS PV04 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 LABELS PV07 PLACARD PV08 SITE PHOTOS COVER PAGE - PV01 DRAWN BY: SoloCAD 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3.ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5.ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS AERIAL VIEW: SHEET INDEX: EQUIPMENT: AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) RACKING: Unirac - 48" O.C. OCCUPANCY: R-3 ZONING: RESIDENTIAL 2017 NEC 2018 IRC 2018 IFC 2018 IBC 2018 IECC STREET VIEW: GENERAL NOTES APPLICABLE GOVERNING CODES SITE SPECIFICATIONS MSP MACC INV INV JB JB JB JB JB JB Rocky Mountain Power IDAHO SITE INFORMATION Matt Lindstrom 950 Greenhaven St Rexburg, ID 83440 AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC Lat, 43.806738 Long, -111.779421 (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) DATE: December 16, 2021 PORTICADE CONSTRUCTION 2000 W. ASHTON BLVD SUITE #170 LEHI, UT 84043 LICENSE: #10744487-5501 CONTRACTOR INFORMATION: EQUIPMENT LEGEND: INVERTERVISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX PROPERTY LINE BATT BATTERY(IES) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 3' OF UTILITY METER SUB SUB PANEL SITE PLAN - PV02 DRAWN BY: SoloCAD 950 Greenhaven St 197'-11" 356'-9" 200'-2" FRONT OF HOME MP1 PITCH: 32° AZIMUTH: 90° STRING 1 MP2 PITCH: 32° AZIMUTH: 90° STRING 2MP3 PITCH: 32° AZIMUTH: 180° STRINGS 2 & 3 & 4 & 5 MP4 PITCH: 32° AZIMUTH: 270° STRING 5 STRING 1: 11 MODULES STRING 2: 11 MODULES STRING 3: 10 MODULES STRING 4: 12 MODULES STRING 5: 12 MODULES 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2222 223333333333 444444444444555 5 5 5 5 5 5 5 5 5 ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING manufactured_truss RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24" ATTACHMENT SPACING 48 MSP MACC INV INV JB JB JB JB JB JB EQUIPMENT INFORMATION: ATTACHMENT MANUFACTURER Unirac ATTACHMENTS Unirac - SFM INFINITY FLASHING ATTACHMENT QTY 94 MICRORAIL QTY 52 MICRORAIL ATT SPLICE QTY 7 MICRORAIL SPLICE QTY 38 CLIP QTY 67 ROOF INFO: Rocky Mountain Power IDAHO SITE INFORMATION Matt Lindstrom 950 Greenhaven St Rexburg, ID 83440 AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC Lat, 43.806738 Long, -111.779421 (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) DATE: December 16, 2021 PORTICADE CONSTRUCTION 2000 W. ASHTON BLVD SUITE #170 LEHI, UT 84043 LICENSE: #10744487-5501 CONTRACTOR INFORMATION: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:56 ARRAY AREA:MODULE COUNT * 18.06ft² = 1011.36 ROOF AREA:4304ft² PERCENT OF ROOF COVERED:23% ARRAY WEIGHT:MODULE COUNT * 50lbs = 2800 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 29.79 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²ROOF ATTACHMENTS - PV03 DRAWN BY: SoloCAD 3' TYP 18" TYP FRONT VIEW SIDE VIEW 48" MAX.1'-11" MAX. ROOF TYPE: Composition Shingle SKIRT (OPTIONAL)PV MODULE (BEHIND SKIRT) CLAMP ASSEMBLY MODULE WIDTH (E) ROOF MEMBRANE ATTACHMENTS PV MODULE (E) BUILDING STRUCTURE DE T A I L , B O T T O M S T A N D O F F Sc a l e : 3 " = 1 ' - 0 " G 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2.5" SKIRT (OPTIONAL) 2.5" MIN. EMBED.FLASHING (E) ROOF MEMBRANE ATTACHMENTS PV MODULE (E) BUILDING STRUCTURE 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2.5" CLAMP ASSEMBLY FLASHING DE T A I L , M I D D L E / T O P S T A N D O F F Sc a l e : 3 " = 1 ' - 0 " H 2.5" MIN. EMBED. 1 EQUIPMENT INFORMATION: ATTACHMENT MANUFACTURER Unirac ATTACHMENTS Unirac - SFM INFINITY FLASHING ATTACHMENT QTY 94 MICRORAIL QTY 52 MICRORAIL ATT SPLICE QTY 7 MICRORAIL SPLICE QTY 38 CLIP QTY 67 ROOF INFO: ROOF INFO: ROOF TYPE asphalt_shingle ROOF FRAMING manufactured_truss RAFTER/TOP CHORD SIZE 2x4 RAFTER/TOP CHORD SPACING 24" ATTACHMENT SPACING 48 Rocky Mountain Power IDAHO SITE INFORMATION Matt Lindstrom 950 Greenhaven St Rexburg, ID 83440 AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC Lat, 43.806738 Long, -111.779421 (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) DATE: December 16, 2021 PORTICADE CONSTRUCTION 2000 W. ASHTON BLVD SUITE #170 LEHI, UT 84043 LICENSE: #10744487-5501 CONTRACTOR INFORMATION: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: PV MODULE COUNT:56 ARRAY AREA:MODULE COUNT * 18.06ft² = 1011.36 ROOF AREA:4304 ft² PERCENT OF ROOF COVERED:23% ARRAY WEIGHT:MODULE COUNT * 50lbs = 2800 DISTRIBUTED LOAD:ARRAY LBS/ATTACHMENTS = 29.79 POINT LOAD: (lbs/ft²)(ARRAY) WEIGHT/AREA = 2.77 lbs/ft²MOUNTING DETAIL - PV04 DRAWN BY: SoloCAD AC DC UL 1741 COMPLIANT INTEGRATED RAPID SHUTDOWN DC DISCONNECT AC DC = = = = = =12 MODULES = = = = = =12 MODULES 3 (N) 60A-2P (N) 40A-2P N G (N) 100A PV COMBINER 6 5 = = = = = =10 MODULES = = = = = =11 MODULES 3 SolarEdge SE10000H-US (240V) UL 1741 COMPLIANT INTEGRATED RAPID SHUTDOWN DC DISCONNECT = = = = = =11 MODULES 21SOLADECK JUNCTION BOX UL50 TYPE 3R STRING (5): 11.4 A DC STRING (4): 11.4 A DC STRING (3): 9.5 A DC STRING (2): 10.5 A DC STRING (1): 10.5 A DC SolarEdge SE7600H-US (240V) 21SOLADECK JUNCTION BOX UL50 TYPE 3R 21SOLADECK JUNCTION BOX UL50 TYPE 3R SOLADECK JUNCTION BOX UL50 TYPE 3R 21SOLADECK JUNCTION BOX UL50 TYPE 3R 21SOLADECK JUNCTION BOX UL50 TYPE 3R SOLADECK JUNCTION BOX UL50 TYPE 3R (E) 120/240 VAC TO UTILITY GRID (E) UTILITY METER (E) LOADS N G SUPPLY SIDE CONNECTION: NEC 230.46, NEC 230.79, NEC 705.12(A) (E) GROUNDING ELECTRODE INTERCONNECTION NOTES 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95] 2. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)] WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH [NEC 240.21(B)] DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. 3. FUSED AC DISCONNECT TO BE USED. 7 (E) 200A-2P (E) 200A MAIN SERVICE PANEL 4 (N) GROUNDING ELECTRODE (N) 100A FUSES PV AC DISCONNECT 100A FUSED, VISIBLE, LOCKABLE, LABELED, OPEN 240V, 2-POLE DATE: December 16, 2021 SITE INFORMATION Matt Lindstrom 950 Greenhaven St Rexburg, ID 83440 AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC Lat, 43.806738 Long, -111.779421 (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) Rocky Mountain Power IDAHO PORTICADE CONSTRUCTION 2000 W. ASHTON BLVD SUITE #170 LEHI, UT 84043 LICENSE: #10744487-5501 CONTRACTOR INFORMATION: GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 2. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. LINE DIAGRAM - PV05 DRAWN BY: SoloCAD VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 3' OF UTILITY METER Conduit & Conductor Schedule TAG WIRE GAUGE DESCRIPTION QTY CONDUIT SIZE CONDUCTOR RATING # OF CONDUCTORS DERATE TEMP. DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 10 AWG PV-WIRE , USE-2, COPPER (L 1, L 2)(2) N/A - FREE AIR 40A N/A - FREE AIR 0.96 38.4A N/A - FREE AIR 6 AWG BARE, COPPER (GROUND)(1) 2 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (L 1, L 2)(2)3/4" EMT 40A 1 0.96 38.4A 11.9% 10 AWG THWN-2, or THHN, or 10/2 NM-B COPPER - (GROUND)(1) 3 10 AWG THHN/THWN-2, COPPER - (L1, L2)(10) 1.25" EMT 40A 0.5 0.96 19.2A 15.5% 10 AWG THHN/THWN-2 - (GROUND)(1) 4 2 AWG THWN-2 COPPER - (L1, L2, NEUTRAL)(3) 1.25" EMT 115A 1 0.96 110.4A 25.6% 8 AWG THWN-2 COPPER - (GROUND)(1) EQUIPMENT SCHEDULE: TYPE:QTY:DESCRIPTION:RATING: MODULES:(56)Silfab SLG-M 380 Wp 380 W INVERTERS:(2)SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V)17600 W AC DISCONNECT(S): (1)PV AC DISCONNECT, 240V, 2-POLE 100A DC OPTIMIZERS:(56)SolarEdge P400 15 Adc 5 6 AWG THWN-2 COPPER - (L1,L2,NEUTRAL)(3) 3/4" EMT 65A 1 0.96 62.4A 32.58% 10 AWG THWN-2 COPPER - (GROUND)(1) 6 8 AWG THWN-2 COPPER - (L1,L2,NEUTRAL)(3) 3/4" EMT 50A 1 0.96 48A 24.62% 10 AWG THWN-2 COPPER - (GROUND)(1) 7 2 AWG THWN-2 COPPER - (L1,L2,NEUTRAL)(2) 1.25" EMT 115A 1 0.96 110.4A 23.15% PER NEC 110.14 (C) - CONDUCTORS WITH TEMPERATURE RATINGS HIGHER THAN SPECIFIED FOR TERMINATIONS SHALL BE PERMITTED TO BE USED FOR AMPACITY ADJUSTMENT,CORRECTION, OR BOTH. Rocky Mountain Power IDAHO SITE INFORMATION Matt Lindstrom 950 Greenhaven St Rexburg, ID 83440 AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC Lat, 43.806738 Long, -111.779421 (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) DATE: December 16, 2021 PORTICADE CONSTRUCTION 2000 W. ASHTON BLVD SUITE #170 LEHI, UT 84043 LICENSE: #10744487-5501 CONTRACTOR INFORMATION: LABEL 5 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54, NEC 690.13 (B)] LABEL 2 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)] *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. JUNCTION BOX OR COMBINER BOX MAIN SERVICE PANEL AC DISCONNECT EXISTING SUB PANEL (IF WHERE POINT OF INTERCONNECTION IS MADE) PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS AC DC INVERTER (S) INTEGRATED DC DISCONNECT 2 7 5 9 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 6 1 1 1 5 (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) 4 6 3 LABELING DIAGRAM: 8OR LABEL 6 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 9 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 8 FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(b)] LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABELING NOTES: 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2.LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] 3 4 1 LABEL 3 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(c)] 2 3 4 1 WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! ! WARNING WARNING THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: ELECTRIC SHOCK HAZARD INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 42 240 WARNING: PHOTOVOLTAIC POWER SOURCE TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS ! RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEMLABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] LABELS - PV06 DRAWN BY: SoloCAD MSP MACC INV INV JB JB JB JB JB JB Rocky Mountain Power IDAHO SITE INFORMATION Matt Lindstrom 950 Greenhaven St Rexburg, ID 83440 AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC Lat, 43.806738 Long, -111.779421 (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) DATE: December 16, 2021 PORTICADE CONSTRUCTION 2000 W. ASHTON BLVD SUITE #170 LEHI, UT 84043 LICENSE: #10744487-5501 CONTRACTOR INFORMATION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: CAUTION DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10]) 950 Greenhaven St, Rexburg ID 83440 PLACARD - PV07 DRAWN BY: SoloCAD FRONT OF HOME MAIN DISTRIBUTION UTILITY DISCONNECT AC DISCONNECT INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH PV ARRAY PV ARRAY PV ARRAY PV ARRAY Rocky Mountain Power IDAHO SITE INFORMATION Matt Lindstrom 950 Greenhaven St Rexburg, ID 83440 AC SYSTEM SIZE: 17.6 kW AC DC SYSTEM SIZE: 21.28 kW DC Lat, 43.806738 Long, -111.779421 (56) Silfab SLG-M 380 Wp PV MODULES (2) SolarEdge SE10000H-US (240V) & SolarEdge SE7600H-US (240V) INVERTER(S) DATE: December 16, 2021 PORTICADE CONSTRUCTION 2000 W. ASHTON BLVD SUITE #170 LEHI, UT 84043 LICENSE: #10744487-5501 CONTRACTOR INFORMATION: SITE PHOTOS: SITE PHOTOS - PV08 DRAWN BY: SoloCAD SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. SFM INFINITY 20% FEWER ATTACHMENTS Save time and money on every project: SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY Make two installs per day your new standard. SFM INFINITY has fewer roof attachments, one tool installation, and pre-assembled components to get you off the roof 40% faster. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, with integrated front trim, trim end caps, dark components, and recessed hardware. 30% LOGISTICS SAVINGS With fewer SKUs and compact components, SFM INFINITY is easier to stock, easier to transport, and easier to lift to the roof. Plus, make more efficient use of your vehicle fleet. SYSTEM OVERVIEW BONDING AND ACCESSORIES 2MW 3MW PART NAME DESCRIPTION TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules N/S BONDING CLAMP Electrically bonds rows of modules 2 3 4 5 6 1 1 4 3 5 6 7 SFM INFINITY 15 Attachments RAIL 20 Attachments 87%OF HOMEOWNERS PREFER MAXIMUM POWER DENSITY Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials, labor, and attachments required by rail. 7 2 PART NAME DESCRIPTION TRIMRAIL Structural front trim provides aesthetic and aligns modules. TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof. Available for comp shingle or tile. MODULE CLIPS Secure modules to TRIMRAIL. MICRORAIL Connects modules to SLIDERS. Provides post-install array leveling. SPLICE Connects and supports modules. Provides east-west bonding. ATTACHED SPLICE also available. SLIDER FLASHKIT Roof attachment and flashing. Available for comp shingle and tile. SolaDeck UL 1741 Combiner/Enclosures Model SD 0783-41 3” Fixed Din Rail fastened using Norlock System **Typical System Configuration 4- Din Rail Mounted Fuse Holders 600VDC 30 AMP 1- Power Distribution Block 600VDC 175AMP 1- Bus Bar with UL lug Basic Features Stamped Seamless Construction 18 Gauge Galvanized Steel Powder Coated Surfaces Flashes into the roof deck 3 Roof deck knockouts .5", .75", 1" 5 Centering dimples for entry/exit fittings or conduit 2 Position Ground lug installed Mounting Hardware Included Available Models: Model SD 0783 - (3” fixed Din Rail) Model SD 0786 - (6” slotted Din Rail) SolaDeck UL50 Type 3R Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Model SD 0786-41 6” Slotted Din Rail fastened using steel studs **Typical System Configuration 4- Din Rail Mounted Fuse Holders 600VDC 30 AMP 4- Din Rail Mounted Terminal Blocks Bus Bars with UL lug **Fuse holders and terminal blocks added in the field must be UL listed or recognized and meet 600 VDC 30 AMP 110C for fuse holders, 600V 50 AMP 90C for rail mounted terminal blocks and 600 V 175 AMP 90C for Power Distribution Blocks. Use Copper Wire Conductors. Cover is trimmed to allow conduit or fittings, base is center dimpled for fitting locations. Model SD 0783-41, wired with Din Rail mounted fuse holders, bus bar and power distribution block. Model SD 0786-41, wired with Din Rail mounted fuse holders, terminal blocks and bus bars. RSTC Enterprises, Inc 2219 Heimstead Road Eau Cliare, WI 54703 For product information call 1(866) 367-7782 SolaDeck Model SD 0783 Max Rated - 600VDC, 120AMPS Product data sheet Specifications Load center, Homeline, 1 phase, 6 spaces, 12 circuits, 100A fixed main lugs, NEMA3R HOM612L100RB Product availability : Stock - Normally stocked in distribution facility Price* : 129.00 USD Main Product Type Load Center Marketing Trade Name Homeline Load Center Type Main lugs Rated Current 100 A Number of Spaces 6 Maximum Number of Single Pole Circuits 12 Enclosure Rating NEMA 3R outdoor Cover Type Surface cover Electrical Connection Lugs Complementary Max Short Circuit Current Rating 10 kA Maximum Number of Tandem Breakers 6 Number of Phases 1 phase Voltage Rating 120/240 V AC Wire Size AWG 8...AWG 1 aluminium/copper Ground Bar Grounding bar (ordered separately) Wiring Configuration 3-wire Busbar Material Tin plated aluminium busbar Enclosure Material Welded galvannealed steel Surface Finish Baked enamel Gray Box Number 2R Height 12.64 in (321 mm) Depth 4.25 in (108 mm) Width 8.90 in (226 mm) Di s c l a i m e r : T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s *  Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Dec 16, 2021 1 Environment Ambient Air Temperature for Operation 23 °F (-5 °C) 104 °F (40 °C) Product Certifications UL listed file E-6294 Ordering and shipping details Category 00149 - HOM 2-8 CKT,MLO,NEMA1&3R Discount Schedule DE3C GTIN 785901061205 Nbr. of units in pkg.1 Package weight(Lbs)9.75 lb(US) (4.423 kg) Returnability Yes Country of origin MX Packing Units Unit Type of Package 1 PCE Package 1 Height 5.00 in (12.7 cm) Package 1 width 10.40 in (26.416 cm) Package 1 Length 14.50 in (36.83 cm) Unit Type of Package 2 PAL Number of Units in Package 2 80 Package 2 Weight 781.28 lb(US) (354.382 kg) Package 2 Height 40.00 in (101.6 cm) Package 2 width 40.00 in (101.6 cm) Package 2 Length 48.00 in (121.92 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration REACh free of SVHC Yes EU RoHS Directive Compliant EU RoHS Declaration Toxic heavy metal free Yes Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) Environmental Disclosure Product Environmental Profile Contractual warranty Warranty Lifetime 2 Dec 16, 2021 Product data sheet Technical Illustration HOM612L100RB Dimensions in. mm Dimensions are approximate. Refer to technical documentation for additional detail. Dec 16, 2021 3 Product data sheet Technical Illustration HOM612L100RB Wiring Diagram 4 Dec 16, 2021 Certificate Number 20090306 – E6294A Page 1 of 1 Report Reference E6294, 1988 January 08 Issue Date 2009 March 06 Issued to: SQUARE D CO 1601 MERCER RD LEXINGTON, KY 40511 USA Panelboards This is to certify that representative samples of Model Descriptions: Panelboards and enclosed panelboards, Type HOM. Have been investigated by Underwriters Laboratories Inc.® in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: The basic standards used to investigate products in this category are ANSI/UL 67, "Panelboards" and CSA-C22.2 No. 29, "Panelboards and Enclosed Panelboards." Additional Information: Ratings: Main lug - 225 maximum amperes, 120/240 maximum volts. Main breaker - 225 maximum amperes, 120/240 maximum volts. Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with “C” and “US” identifiers: the word “LISTED”; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product Issued by: Jim Larin Review ed by: Thomas Skibbs Jim Larin, Customer Service Specialist Thomas Skibbs, Staff Engineering Associate Underwriters Laboratories Inc. Underwriters Laboratories Inc. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL For questions in The United States of America you may call 1-877-UL-HELPS. Product data sheet Specifications Safety switch, general duty, fusible, 100A, 2 poles, 30 hp, 120 VAC, NEMA 3R, bolt-on provision, neutral factory installed D223NRB Product availability : Stock - Normally stocked in distribution facility Price* : 480.00 USD Main Product Single Throw Safety Switch Duty Rating General duty Device Application Residential Disconnect Type Fusible disconnect switch Factory Installed Neutral Neutral (factory installed) Phase 3 phase Number of Poles 2 Current Rating 100 A Voltage Rating 240 V AC Enclosure Rating NEMA NEMA 3R Maximum Horse Power Rating 7.5 hp 240 V at AC 60 Hz for 1 phase conforming to NEC 240.6 15 hp 240 V at AC 60 Hz for 3 phase conforming to NEC 240.6 15 hp 240 V at AC 60 Hz for 1 phase conforming to NEC 430.52 30 hp 240 V at AC 60 Hz for 3 phase conforming to NEC 430.52 Complementary Short Circuit Current Rating 100 kA maximum depending on fuse H, K or R Fuse type H, K or R Mounting Type Surface Electrical Connection Lugs Wiring configuration 3-wire Wire Size AWG 14...AWG 1 copper AWG 12...AWG 1 aluminium Tightening torque 35 lbf.in (3.95 N.m) 0.00…0.01 in² (2.08…5.26 mm²) (AWG 14...AWG 10) 40 lbf.in (4.52 N.m) 0.01 in² (8.37 mm²) (AWG 8) 35 lbf.in (3.95 N.m) (AWG 14...AWG 10) 45 lbf.in (5.08 N.m) 0.02…0.03 in² (12.3…21.12 mm²) (AWG 6...AWG 4) 50 lbf.in (5.65 N.m) (AWG 3...AWG 1) Depth 6.5 in (165.10 mm) Width 10.56 in (268.22 mm) Height 17.5 in (444.50 mm) Di s c l a i m e r : T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s *  Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Dec 16, 2021 1 Net Weight 15.43 lb(US) (7 kg) Environment Certifications UL listed file E2875 Ordering and shipping details Category 00106 - D & DU SW,NEMA3R, 30-200A Discount Schedule DE1A GTIN 785901460701 Nbr. of units in pkg.1 Package weight(Lbs)15.60 lb(US) (7.076 kg) Returnability Yes Country of origin US Packing Units Unit Type of Package 1 PCE Package 1 Height 7.30 in (18.542 cm) Package 1 width 10.80 in (27.432 cm) Package 1 Length 20.00 in (50.8 cm) Unit Type of Package 2 PAL Number of Units in Package 2 40 Package 2 Weight 650.00 lb(US) (294.835 kg) Package 2 Height 41.00 in (104.14 cm) Package 2 width 41.00 in (104.14 cm) Package 2 Length 48.00 in (121.92 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration REACh free of SVHC Yes EU RoHS Directive Compliant EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Product out of China RoHS scope. Substance declaration for your information. Environmental Disclosure Product Environmental Profile PVC free Yes Contractual warranty Warranty 18 months 2 Dec 16, 2021 Product data sheet Technical Illustration D223NRB Dimensions DU323RB REQUIRES FIELD INS TALLATION OF EQUIPMEN T GROUNDING KI T GTK0610 WHEN USED AS SE RVICE EQUIPMEN T. TOP OF NEM A TYPE 3R DEVICES H AVE PROVISIONS FOR MAX 2.50/[64] BO LT-ON HUB. WHEN MOUNTING, ALLOW 4.00/[102] MIN. CLEARANCE BETWEEN ENCLOSURES FOR OPENING OF SIDE HINGED DOOR. IN. [MM] ALL DIMENSIONS ARE APPROXIM ATE. REFER TO TECHNICA L DR AWINGS AND DOCUMEN TATION FOR COMPLETE DE TAILS. TI_DIM_GD1003R Dec 16, 2021 3 Product data sheet Technical Illustration D223NRB Wiring Diagram 223NRB CD223NRB 4 Dec 16, 2021