Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 21-00669 - 1080 Cypress Loop - New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : RPRPNBK2030090 - New SFR Address : Record Type : New Single Family Residence Document Filename : 1800 sq fr spec garage right side full set 03.29.2021 (1).pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00669 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A1 Free text Larry Beesley : Building Open 1 Tempored A1 Ellipse Larry Beesley : Building Open 1 A1 Line Larry Beesley : Building Open 1 A1 Free text Larry Beesley : Building Open 1 SD needs to be 3' from bathroom door opening A1 Free text Larry Beesley : Building Open 1 SD A1 Free text Larry Beesley : Building Open 1 SD CO A1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector A2 Free text Larry Beesley : Building Open 2 Tempered A2 Free text Larry Beesley : Building Open 2 F A2 Free text Larry Beesley : Building Open 2 F A2 Free text Larry Beesley : Building Open 2 F A2 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector A3 Free text Larry Beesley : Building Open 3 SD A3 Free text Larry Beesley : Building Open 3 SD CO New Single Family Residence Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A3 Free text Larry Beesley : Building Open 3 SD A3 Free text Larry Beesley : Building Open 3 SD CO A3 Line Larry Beesley : Building Open 3 A3 Free text Larry Beesley : Building Open 3 3' A3 Free text Larry Beesley : Building Open 3 SD A3 Free text Larry Beesley : Building Open 3 Unfinished basement A3 Stamp Larry Beesley : Building Open 3 Approved - Building Inspector A4 Free text Larry Beesley : Building Open 4 1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl. interior bearing walls) R403.1.6.1 A4 Stamp Larry Beesley : Building Open 4 Approved - Building Inspector A5 Free text Larry Beesley : Building Open 5 Street Number Displayed on House A5 Free text Larry Beesley : Building Open 5 Roof Ventilation as per R806 A5 Free text Larry Beesley : Building Open 5 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) A5 Free text Larry Beesley : Building Open 5 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A5 Free text Larry Beesley : Building Open 5 Minimum Frost Depth Ground Surface to Bottom of Footing 36" A5 Stamp Larry Beesley : Building Open 5 Approved - Building Inspector A6 Free text Larry Beesley : Building Open 6 Roof Ventilation as per R806 A6 Free text Larry Beesley : Building Open 6 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) A6 Free text Larry Beesley : Building Open 6 Minimum Frost Depth Ground Surface to Bottom of Footing 36" A6 Free text Larry Beesley : Building Open 6 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A6 Stamp Larry Beesley : Building Open 6 Approved - Building Inspector A7 Ellipse Larry Beesley : Building Open 7 A7 Ellipse Larry Beesley : Building Open 7 A7 Ellipse Larry Beesley : Building Open 7 A7 Ellipse Larry Beesley : Building Open 7 A7 Free text Larry Beesley : Building Open 7 1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl. interior bearing walls) R403.1.6.1 A7 Rectangle Larry Beesley : Building Open 7 A7 Stamp Larry Beesley : Building Open 7 Approved - Building Inspector Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A8 Ellipse Larry Beesley : Building Open 8 A8 Ellipse Larry Beesley : Building Open 8 A8 Ellipse Larry Beesley : Building Open 8 A8 Ellipse Larry Beesley : Building Open 8 A8 Line Larry Beesley : Building Open 8 A8 Rectangle Larry Beesley : Building Open 8 A8 Stamp Larry Beesley : Building Open 8 Approved - Building Inspector A9 Free text Larry Beesley : Building Open 9 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) A9 Stamp Larry Beesley : Building Open 9 Approved - Building Inspector Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Tempored SD needs to be 3' from bathroom door opening SD SD CO Tempered F F F SD SD CO SD SD CO 3' SD Unfinished basement 1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl. interior bearing walls) R403.1.6.1 Street Number Displayed on House Roof Ventilation as per R806 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Minimum Frost Depth Ground Surface to Bottom of Footing 36" Roof Ventilation as per R806 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Minimum Frost Depth Ground Surface to Bottom of Footing 36" Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. 1/2" Anchor bolts with 3" x 3" x 1/4" square washers (incl. interior bearing walls) R403.1.6.1 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)