Loading...
HomeMy WebLinkAboutREDLINED PLANS - 22-00816 - 491 Morgan Dr - Solar PanelsAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : 491 Morgan Dr - Solar Panels Address : 491 Morgan Dr Application Type : Document Filename : Christina Allred plans.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments PV-2 Free Text Larry Beesley : Building Open 2 Insert The pathways must be 36" at the ridge because the panels are covering more than 33% of this section of roof. R324.6.2 PV-3 Callout Alex Owens : Electrical Open 3 Please provide proof of listing from an accredited laboratory for this roof mounted junction box. # 22-00816 Solar Panels Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 11.08.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) ADDITIONAL NOTES P L A N S E T L E G E N D S H E E T I N D E X V I C I N I T Y M A P A P P L I C A B L E C O D E S A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N OCCUPANCY: R-3CONSTRUCTION TYPE: V-BUNSPRINKLERED ALL CONDUIT TO RUN ON EXTERIOR OF HOUSE UNLESSOTHERWISE NOTED P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E PROJECT INFORMATION, VICINITY MAP ISSUED FOR: PERMIT DATE 10/14/2022 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM CHRISTINA ALLRED DESIGNED BY CONTRACTOR INFORMATION P V - 1 491, MORGAN DRIVE, REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ ( E ) E X I S T I N G ( N ) N E W E X T E X T E R I O R I N T I N T E R I O R E M T E L E C T R I C A L M E T A L L I C T U B I N G R M T R I G I D M E T A L L I C T U B I N G F M C F L E X I B L E M E T A L L I C C O N D U I T V O C V O L T A G E O P E N C I R C U I T V M P V O L T A G E A T M A X . P O W E R I S C S H O R T C I R C U I T C U R R E N T I M P C U R R E N T A T M A X . P O W E R N T S N O T T O S C A L E MSPSUBACDCSLCMINVJBCBBAT M A I N S E R V I C E P A N E L S U B S E R V I C E P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X B A T T E R Y P V P R O D U C T I O N M E T E R R A P I D S H U T D O W N D I S C O N N E C T PMRSD C H R I S T I N A A L L R E D 4 9 1 M O R G A N D R I V E , R E X B U R G , I D 8 3 4 4 0 3 9 - U R E F B M 4 0 0 M F G - B B ( 4 0 0 W ) P H O T O V O L T A I C M O D U L E S 1 - S O L A R E D G E S E 7 6 0 0 H - U S ( 7 6 0 0 W ) I N V E R T E R 1 - S O L A R E D G E S E 5 0 0 0 H - U S ( 5 0 0 0 W ) I N V E R T E R S Y S T E M S I Z E : 1 5 . 6 0 0 K W D C S T C A R R A Y A R E A : 8 2 0 . 7 3 S F 1. ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITHTHE CODE AND THE MANUFACTURES INSTALLATIONINSTRUCTIONS.2. ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THEPLACARD.3. LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT.4. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC 2017CODE.5. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED.6. ALL PLUMBING AND MECHANICAL ROOF VENTS TO CLEARFROM PHOTOVOLTAIC ARRAY, OR EXTEND ABOVE SOLARPANELS.7. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ONRESIDENTIAL STRUCTURE.8. DESIGN COMPLYING WITH THE IBC 2018 CODE AND ALLLOCAL ORDINANCES AND POLICIES.9. THE PROJECT HAS BEEN DESIGNED TO WITHSTAND AMINIMUM 110 MPH WIND LOAD.10. THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITYIS OBTAINED.11. IF THE MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLEGROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE.12. EACH MODULE WILL BE GROUNDED USING THE SUPPLIEDCONNECTION POINTS IDENTIFIED ON THE MODULE ANDTHE MANUFACTURERS INSTALLATION INSTRUCTIONS.13. A LADDER SHALL BE IN PLACE FOR INSPECTION INCOMPLIANCE WITH OSHA REGULATIONS.14. PROPER ACCESS AND WORKING CLEARANCE WILL BEPROVIDED "WARNING: PV POWER SOURCE" TO BE PLACEDEVERY 10 FT.15. GFCI PROTECTION IN INVERTER. A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C / I R C / I F C 2 0 1 8 C O D E 10/24/2022 MSPACINV MTRACINV A E R I A L V I E W SITE PLAN, AERIAL VIEW N ISSUED FOR: PERMIT DATE 10/14/2022 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM CHRISTINA ALLRED DESIGNED BY CONTRACTOR INFORMATION P V - 2 491, MORGAN DRIVE, REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ SITE PLAN P A N E L P L A C E M E N T M A Y D I F F E R F R O M A P P R O V E D D E S I G N D U E T O U N F O R E S E E N O B S T R U C T I O N S O R P E R M I T T I N G S E T B A C K S P R O P O S E D S Y S T E M D C S I Z E / A C S I Z E : 1 5 . 6 0 0 K W - D C / 1 2 . 6 0 0 K W - A C S O L A R P V M O D U L E I N V I N V E R T E R M S P M A I N S E R V I C E P A N E L A C A C D I S C O N N E C T M T R M E T E R TOTAL # OF PANELS:39 A B B R E V I A T I O N S S C A L E : N T S S C A L E : N T S M O R G A N D R I V E ROOF TYPE:SHINGLEROOF #1 A C D I S C O N N E C T W I T H I N 3 ’ F R O M U T I L I T Y M E T E R R O O F D E S C R I P T I O N R O O F A R R A Y P I T C H A Z I M U T H # 1 1 8 ° 3 5 9 ° # 2 1 8 ° 2 7 1 ° # 3 8 ° 3 5 9 ° 3 F T / 1 8 I N C H F I R E S E T B A C K ROOF #2 ROOF #310/24/2022 ELECTRICAL SINGLE LINE DIAGRAM E L E C T R I C A L N O T E S SINGLE LINE DIAGRAM R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) ISSUED FOR: PERMIT DATE 10/14/2022 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM CHRISTINA ALLRED DESIGNED BY CONTRACTOR INFORMATION P V - 3 491, MORGAN DRIVE, REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . M O D U L E : U R E F B M 4 0 0 M F G - B B ( 4 0 0 W ) V o c = 3 7 . 2 0 V I s c = 1 3 . 6 8 A V m p = 3 1 . 1 7 V I m p = 1 2 . 8 4 A 1ELECTRICAL LINE DIAGRAMPV-3SCALE: NTS P R O P O S E D S Y S T E M D C S I Z E / A C S I Z E : 1 5 . 6 0 0 K W - D C / 1 2 . 6 0 0 K W - A C 1ELECTRICAL LINE DIAGRAMPV-3SCALE: NTS 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N 2 9 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 1 ) ( B ) 1ELECTRICAL LINE DIAGRAMPV-3SCALE: NTS 1ELECTRICAL LINE DIAGRAMPV-3SCALE: NTS ELECTRICAL E Q U I P M E N T C A L L O U T S 15,600W TOTAL SOLAR ARRAY39 URE FBM400MFG-BB (400W) PANELSWIRE AND CONDUIT CALLOUTS SOLADECK M O D E L 0 7 8 3 - 4 1 J U N C T I O N BOX/ROOF P E N E T R A T I O N , 6 0 0 V 7.6kW INVER T E R U N G R O U N D E D SOLAREDG E S E 7 6 0 0 H - U S ( 2 4 0 V ) I N V E R T E R 240VAC, 32A , N E M A 3 R , U L L I S T E D , (W/ INTEGR A T E D D C D I S C O N N E C T ) WITH INTEG R A T E D G F P , W / I N T E G R A T E D A F P (2) #10 AWG PV/RHW-2 IN FREE AIR(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT/FMC(2) #8 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT SOLAREDGE S 4 4 0 O P T I M I Z E R O N E P E R P A N E L ABCDE F SQUARE D S A F E T Y S W I T C H , # D 2 2 2 N R B 250 VAC, 60 A , N E M A 3 R , F U S E D , U L , N E M A , CSA, NOM C E R T I F I E D W / 4 0 A F U S E S _ ~ M P P T 1 M P P T 2 3 C _ ~ M P P T 1 M P P T 2 4 G L1L2NG D3L1L2NGL1L2NGHL1L2NG4ENG30ABREAKER 28150A40ABACKFEED 26 F (2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 3/4" EMT 2 STRINGS OF 11 MODULES CONNECTED IN SERIES(@SOLAREDGE SE7600H-US INVERTER)LABEL TO BE INSTALLED"MANUAL DISCONNECT FORPARALLEL GENERATION 2 OF 2"LABEL TO BE INSTALLED"MANUAL DISCONNECT FORPARALLEL GENERATION 1 OF 2"200A (E) MAI N S E R V I C E P A N E L S P L I T B U S , 1 Ø , 2 4 0 V (W/ 150A MA I N B R E A K E R A T L O C A L I Z E D B U S B A R CENTER FE D & 5 0 A M A X R A T E D P A R A L L E L DISTRIBUTI O N B R E A K E R O N L Y S L O T ) 2 0 0 A B I - D I R E C T I O N A L U T I L I T Y M E T E R , 1 Ø , 2 4 0 V 1234 1 STRING OF 9 MODULES1 STRING OF 8 MODULES CONNECTED IN SERIES(@SOLAREDGE SE5000H-US INVERTER) 5 . 0 k W I N V E R T E R U N G R O U N D E D S O L A R E D G E S E 5 0 0 0 H - U S ( 2 4 0 V ) I N V E R T E R 2 4 0 V A C , 2 1 A , N E M A 3 R , U L L I S T E D , ( W / I N T E G R A T E D D C D I S C O N N E C T ) W I T H I N T E G R A T E D G F P , W / I N T E G R A T E D A F P G AC DISCONNECTWITHIN 3’ FROM UTILITY METER H S Q U A R E D S A F E T Y S W I T C H , # D 2 2 1 N R B 2 5 0 V A C , 3 0 A , N E M A 3 R , F U S E D , U L , N E M A , C S A , N O M C E R T I F I E D W / 3 0 A F U S E S 9 M O D U L E S I N S E R I E S B A 2 1 O N E P E R P A N E L 8 M O D U L E S I N S E R I E S A B O N E P E R P A N E L 2 1 S T R I N G 1 S T R I N G 2 1 1 M O D U L E S I N S E R I E S B A 2 1 O N E P E R P A N E L 1 1 M O D U L E S I N S E R I E S A B O N E P E R P A N E L 2 1 S T R I N G 1 S T R I N G 2 REQUIRED SIGNAGE ISSUED FOR: PERMIT DATE 10/14/2022 www.bigdogenergy.com SOLAR PHOTOVOLTAIC SYSTEM CHRISTINA ALLRED DESIGNED BY CONTRACTOR INFORMATION P V - 4 491, MORGAN DRIVE, REXBURG, ID 83440 BIG DOG RENEWABLE ENERGY CONTRACTOR LIC #: IDAHO #017916 620 PHEASANT RIDGE DR CHUBBUCK, ID 83202 208-242-3352 T 208-232-5935 F X__________________ REQUIRED SIGNAGE 2. LABEL FOR SOLAR AC DISCONNECT: S Y S T E M A C V O L T A G E : 2 4 0 V T O T A L R A T E D A C A M P S : 4 0 A S Y S T E M A C V O L T A G E : 2 4 0 V 3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8"HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITALLETTERS, WHITE ON RED BACKGROUND AND A REFLECTIVE,WEATHER RESISTANT MATERIAL.1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 1/4"HIGH LETTERING PER NEC 690-17.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING: FOLLOWING WORDING:THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAINSERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED.CUSTOMER OWNEDON SITE POWER GENERATIONSYSTEM DISCONNECT 8. T H E F O L L O W I N G S I G N M U S T B E P R O V I D E D O N T H E O U T S I D E ( O R W I T H I N 3 ' O F ) T H E S E R V I C E P A N E L B O A R D , A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 1 ) : R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N A L L S I G N A G E M U S T B E P E R M A N E N T L Y A T T A C H E D A N D B E W E A T H E R R E S I S T A N T / S U N L I G H T R E S I S T A N T A N D C A N N O T B E H A N D - W R I T T E N . N E C 1 1 0 . 2 1 ( B ) FIRE DEPARTMENT REQUIRED SIGNAGE4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT:5. LABEL INSTALLATION AT INTERCONNECT BREAKER:9. S I G N A G E R E Q U I R E D A T S E R V I C E P A N E L B O A R D P E R N E C 6 9 0 . 5 4 : 7. A T P V D I S C O N N E C T S W I T C H A S R E Q U I R E D P E R N E C 6 9 0 . 5 6 ( C ) ( 3 ) : 6. R E F L E C T I V E P L A C A R D A T S E R V I C E S T A T I N G : "SOLAR AC DISCONNECT"WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALSON BOTH THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION.WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE. D I R E C T C U R R E N T P H O T O V O L T A I C S O U R C E S Y S T E M A C V O L T A G E : 2 4 0 V M A X A C C I R C U I T C U R R E N T : 3 2 A M A X D C C U R R E N T P E R O P T I M I Z E R : 1 5 A 1 1 . S I G N A G E R E Q U I R E D A T S T R I N G I N V E R T E R P E R N E C 6 9 0 . 5 3 : D I R E C T C U R R E N T P H O T O V O L T A I C S O U R C E S Y S T E M A C V O L T A G E : 2 4 0 V M A X A C C I R C U I T C U R R E N T : 2 1 A M A X D C C U R R E N T P E R O P T I M I Z E R : 1 5 A 1 0 . A T E V E R Y E N C L O S U R E , E V E R Y 1 0 ’ A L O N G C O N D U I T O R M C C A B L E , A N A T E A C H S I D E O F W H E R E T H E C O N D U I T O R C A B L E P A S S E S T H R O U G H A W A L L , F L O O R , O R A N Y O T H E R P A R T I T I O N . W A R N I N G : P O W E R S O U R C E T H E M A R K I N G S S H A L L B E P E R M A N E N T L Y A F F I X E D A N D V I S I B L E A F T E R I N S T A L L A T I O N P E R N E C 6 9 0 . 3 1 ( G ) ( 3 - 4 ) . WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEM M A N U A L D I S C O N N E C T F O R P A R A L L E L G E N E R A T I O N 1 O F 2 1 1 . L A B E L S T O B E I N S T A L L E D O N F A C E O F A C D I S C O N N E C T S : M A N U A L D I S C O N N E C T F O R P A R A L L E L G E N E R A T I O N 2 O F 2