Loading...
HomeMy WebLinkAboutREDLINED INFRASTRUCTURE LOT LAYOUT PLAY - 20-00739 - SITE PLAN - Teton River Flats Community Housing - six 4-plexes - LoreneAuthor Name Author Email Author Phone No.: Joel Gray Joel.Gray@rexburg.org 208-372-2331 Description : SITE PLAN - Teton River Flats Community Housing - six 4-plexes - Lorene Address : RPR6N40E203550 & RPRXBCA0203370 Application Type : Document Filename : Infrastructure, Lot Layout Plan - Teton River Flats.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 3 - HORIZONTAL CONTROL Callout Joel Gray : PW Open 5 Sidewalk installed per City of Rexburg Standards. 3 - HORIZONTAL CONTROL Callout Joel Gray : PW Open 5 Concrete approach required. 3 - HORIZONTAL CONTROL Callout Joel Gray : PW Open 5 Has the easement been obtained? 3 - HORIZONTAL CONTROL Callout Joel Gray : PW Open 5 Fabric required 3 - HORIZONTAL CONTROL Callout Joel Gray : PW Open 5 Additional ROW required per Development Agreement 3 - HORIZONTAL CONTROL Free text Joel Gray : PW Open 5 Streetlights required per City Standards. DEQ Approval Required. 5 - LORENE STREET STA 1+00 TO 4+00 Callout Joel Gray : PW Open 7 Pipe must be laid flatter. 5 - LORENE STREET STA 1+00 TO 4+00 Callout Joel Gray : PW Open 7 Culinary service can come off fire line if there is capacity. Valve required on culinary line. # 20-00739 Civil Site Plan Report Date: 22-10-2020 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 5 - LORENE STREET STA 1+00 TO 4+00 Callout Joel Gray : PW Open 7 All manholes must be above flood plain or have bolted lids. 6 - LORENE STREET STA 4+00 TO 8+50 Callout Joel Gray : PW Open 8 Sanitary Sewer line to be extnded to intersection to the East. 6 - LORENE STREET STA 4+00 TO 8+50 Callout Joel Gray : PW Open 8 Water line to have tee and valves for future. 6 - LORENE STREET STA 4+00 TO 8+50 Callout Joel Gray : PW Open 8 Manholes not in street must be 24" above surrounding ground level. 10 - DRIVE 2 4+50 TO 6+25 Callout Joel Gray : PW Open 12 Trash Enclosure pads are too small per City Standards. Report Date: 22-10-2020 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) 0+ 7 8 1+ 0 0 2+ 0 0 3+00 4+00 5+00 6+00 7+00 7+28 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+ 0 0 8+ 4 2 0+ 7 8 1+ 0 0 2+ 0 0 3+ 0 0 4+ 0 0 5+006+006+14 S89° 31' 34"W 315.15' N0 ° 1 2 ' 2 5 " W 14 0 . 0 0 ' N89° 31' 34"E 645.01' N0 ° 1 1 ' 4 3 " W 19 9 . 7 9 ' S89° 33' 55"W 329.89' S0 ° 1 2 ' 2 5 " E 37 0 . 0 1 ' N89° 31' 34"E 122.43' S2 ° 0 2 ' 5 2 " E 14 0 . 6 0 ' S89° 46' 18"W 126.94' L1 L2 C1 L3 L4 L5 L6 4872 4871 4872 4872 4 8 7 2 4871 4872 4 8 7 2 4873 4872 Lorene St Number L1 C1 L2 Begin Station 1+00.00 7+16.74 7+94.09 End Station 7+16.74 7+94.09 8+42.31 Radius 49.50 Length 616.74 77.35 48.23 Line/Chord Direction N89° 31' 34.07"E N44° 45' 47.04"E N0° 00' 00.00"E Begin Point N: 791812.64, E: 759370.84 N: 791817.74, E: 759987.56 N: 791867.24, E: 760036.65 End Point N: 791817.74, E: 759987.56 N: 791867.24, E: 760036.65 N: 791915.47, E: 760036.65 ROAD 1 Number L3 L4 Begin Station 0+78.00 2+35.72 End Station 2+35.72 7+28.45 Radius Length 157.72 492.73 Line/Chord Direction S0° 00' 00.00"E N90° 00' 00.00"E Begin Point N: 791834.94, E: 759406.33 N: 791677.22, E: 759406.33 End Point N: 791677.22, E: 759406.33 N: 791677.22, E: 759899.06 ROAD 2 Number L5 L6 Begin Station 0+78.00 4+38.76 End Station 4+38.76 6+14.12 Radius Length 360.76 175.35 Line/Chord Direction S0° 00' 00.00"E S89° 57' 45.16"W Begin Point N: 791838.77, E: 759870.06 N: 791478.01, E: 759870.06 End Point N: 791478.01, E: 759870.06 N: 791477.89, E: 759694.71 6" R = 1/2" 6" 1" 4" R = 1" 1' 1/2" 6"1" 6" 24" CHECK BY SHEETS DRAWN BY JOB NO: DATE: OF SHEET BDJTKP SH E E T N A M E : PR O J E C T : LO C A T I O N : 2020-083 DATE:DATE: September 10, 2020 DA T E RE V I S I O N S CL I E N T : Th e C i v i l C o n n e c t i o n 11 5 0 H o l l i p a r k D r . I d a h o F a l l s , I D 8 3 4 0 1 20 8 . 6 8 1 . 8 5 9 0 PRELIMINARY FOR REVIEW ONLY 3 15 TE T O N R I V E R F L A T S HO R I Z O N T A L C O N T R O L RE X B U R G , I D APPROVED BY ________________________DATE:____________ City of REXBURG LORENE STREET DRIVE 1 DR I V E 2 4.00' 22.00'2.50'5.50' 30.00' LORENE ROAD PUBLIC IMPROVEMENTS SCALE: 1"=5' ROWCENTERLINE 2% 2.5" OF PLANT MIX ASPHALT PAVEMENT 4" OF 3/4" AGGREGATE BASE 12" OF STANDARD PIT RUN MATERIAL 6" HIGH BACK CURB PER REXBURG CITY STANDARDS 2% LANDSCAPE STRIP LEGEND EXIST. CATCH BASIN PROPOSED CATCH BASIN EXIST. FIRE HYDRANT PROPOSED FIRE HYDRANT EXIST. LIGHT POLE PROPOSED STREET LIGHT PROPOSED WATER VALVE PROPOSED SANITARY SEWER MANHOLE EXIST. CURB & GUTTER PROPERTY LINE GRADE BREAK SAW CUT STREET RIGHT-OF-WAY (ROW) EASEMENT LINE EXIST. FENCE LINE PROPOSED UNDERGROUND POWER EXIST. SANITARY SEWER LINE PROPOSED SANITARY SEWER LINE PROPOSED WATER LINE EXIST. WATERLINE PROPOSED SANITARY SEWER SERVICE PPROPOSED WATER SERVICE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED CONCRETE SIDEWALK PROPOSED ASPHALT PROPOSED LANDSCAPING PROPOSED BUILDINGS EXISTING ASPHALT TO BE PROTECTED PROPOSED STORM DRAIN MANHOLE PROPOSED CURB & GUTTER EXIST. STORM DRAINLINE PROPOSED STORM DRAINLINE EXIST. POWER POLE SITE INFORMATION: AREA: 156,242 SQ FT (3.59 ACRES) BUILDINGS: 29 (116 UNITS) UNITS/ACRE: 32 PARKING: 196 PARKING STALLS (6 ADA STALLS) LANDSCAPE: 55,013 SQ FT (35%) STORM TECH AREA 1 STORM TECH AREA 2 VOLUME CALC.38,282 0.9 1.5 AREA (sq.ft.)PRECIPITATION FACTOR INTENSITY (in) 4,307 CU FT REQ VOLUME STORM TECH VOLUME VOLUME (cu ft) 4,501 INFILTRATION MATERIAL PIT RUN BASE INFILTRATION AREA 1111 sq ft RETENTION TIME 3 HRS STORM TECH AREA 2 (SEE SHEET 11 AND 12 FOR DETAILS) VOLUME CALC.36,992 0.9 1.5 AREA (sq.ft.)PRECIPITATION FACTOR INTENSITY (in) 4,162 CU FT REQ VOLUME STORM TECH VOLUME VOLUME (cu ft) 4,132 INFILTRATION MATERIAL PIT RUN BASE INFILTRATION AREA 992 sq ft RETENTION TIME 3 HRS CITY STORM TECH (SEE SHEET 13 FOR DETAILS) VOLUME CALC.19,872 0.9 1.5 AREA (sq.ft.)PRECIPITATION FACTOR INTENSITY (in) 2,236 CU FT REQ VOLUME STORM TECH VOLUME VOLUME (cu ft) 2,247 INFILTRATION MATERIAL PIT RUN BASE INFILTRATION AREA 992 sq ft 74.9 CU FT VOLUME PER INFILTRATOR NO. OF INFILTRATORS 30 STORM TECH AREA 1 (SEE SHEET 11 AND 12 FOR DETAILS) 4" DEPTH CRUSHED 3 4" MINUS AGGREGATE LEVELING COURSE COMPACTED TO 95% ASTM D698 10" DEPTH UNCRUSHED AGGREGATE SUBBASE COURSE COMPACTED TO 95% ASTM D698 SUBGRADE EARTH COMPACTED TO 95% ASTM D698 2.5" DEPTH ASPHALT PLANT MIX TYPICAL ASPHALT ROAD CITY STORM TECH SYSTEM BUILDING REVEAL: THERE IS AN ASSUMED 0.5' REVEAL FROM FINISH FLOOR TO FINISH GRADE. 6" LIP DOWN CURB DETAIL SCALE: 1"=1' POWER NOTE: SEE ROCKY MOUNTAIN POWER CONTRACTOR'S MAP FOR PROPOSED POWER FACILITIES. FIRE CODE NOTE: 1.D103.6.1 ROADS ARE 20 TO 26 FEET IN WIDTH. FIRE LANE SIGNS ARE SPECIFIED IN SECTION D103.6 APPARATUS ACCESS ROADS THAT ARE 20 TO 26 FEET WIDE. 2.CURBS SHALL BE PAINTED RED FOUR FEET ON EACH SIDE OF THE EVERY FIRE HYDRANT. 24.00' 17.00' TYP 9.00' TYP 16.00' TYP 9.00' TYP 9.00' 16.00' 26.00' 16.00' 9.00' 9.00' 16.00' 9.00' 26.04' 9.00' 16.00' 11.04' 11.57' 32.38' 21.32' 16.93' 23.35' 11.46' 21.69' 12.00' 11.24' LANDSCAPE NOTE: FINAL LANDSCAPE SHOULD SLOPE AWAY FROM BUILDINGS SANITARY SEWER SERVICE NOTE: CLEANOUTS REQUIRED FOR CURRENT PLUMBING CODE NOT SHOWN ON PLANS. CONTRACTOR IS RESPONSIBLE TO VERIFY SEWER CLEANOUT LOCATIONS. 16.00' 15.06' Sidewalk installed per City of Rexburg Standards. Concrete approach required. Has the easement been obtained? Fabric required Additional ROW required per Development Agreement Streetlights required per City Standards. DEQ Approval Required. DATUM ELEV 4860.00 4864 4868 4872 1+00 48 7 0 . 7 48 7 0 . 6 6 48 7 0 . 7 48 7 0 . 7 2 2+00 48 7 1 . 2 48 7 1 . 2 3 48 7 1 . 3 48 7 1 . 3 1 3+00 48 7 1 . 2 48 7 1 . 2 3 48 7 1 . 4 48 7 1 . 3 5 4+00 48 7 1 . 4 48 7 1 . 3 5 -0.40% 1.23% 0.60% PV I S t a . = 1 + 0 0 . 0 0 El e v . = 4 8 7 0 . 6 5 8 PV I S t a . = 1 + 6 7 . 7 3 El e v . = 4 8 7 1 . 4 9 0 PV I S t a . = 2 + 8 4 . 4 6 El e v . = 4 8 7 2 . 1 9 0 -0.40% 1.23% 0.60% PV I S t a . = 1 + 0 0 . 0 0 El e v . = 4 8 7 0 . 6 5 8 PV I S t a . = 1 + 6 7 . 7 3 El e v . = 4 8 7 1 . 4 9 0 PV I S t a . = 2 + 8 4 . 4 6 El e v . = 4 8 7 2 . 1 9 0 Install 29' of 8" C50 DI Pipe @ 6' Min Cover Install 6' of 8" C50 DI Pipe @ 6' Min Cover Install 56' of 8" C50 DI P i p e @ 6 ' M i n C o v e r Install 57' of 8" C50 DI Pipe @ 6' Min Cover Install 56' of 8" C50 DI Pipe @ 6' M i n C o v e r Install 19' of 8" C50 DI Pipe @ 6' Min CoverSSMH 1 Sta:1+44.63 OFF:-16.14L Rim:4870.88 S INV IN:4862.49 E INV IN:4862.49 W INV OUT:4862.39 Install 40' of 8" PVC SDR 35 San. Pipe @ 0.40% Install 463' of 8" PVC SDR 35 San. Pipe @ 0 . 4 0 % Install 52' of 8" C50 DI Pipe @ 6' Min Cover Install Hydrant Flange: 4872.09' STA: 3+86.59 OFF: 27.50 0+ 7 8 1+ 0 0 1+00 2+00 3+00 4+00 -2.19% 4870.37 TBC-PI-LP 4871.57 TBC-PI 4871.77 TBC-PI-HP -2.59% 4871.33 TBC-PC BUILDING:A1 AREA: 1,819 SQ FT FF: 4871.25 BUILDING:A2 AREA: 1,819 SQ FT FF: 4871.25 BUILDING:B1 AREA: 1,819 SQ FT FF: 4872.75 BUILDING:B2 AREA: 1,819 SQ FT FF: 4873.00 BUILDING:B3 AREA: 1,819 SQ FT FF: 4873.25 BUILDING:B4 AREA: 1,819 SQ FT FF: 4873.50 AREA: 1,819 SQ FT 4870.64 TBC-PC 4870.85 TBC-PC 4870.61 TBC-PC 4870.63 EO-MATCH 0402.4.1.A.1-06 0402.4.1.A.1-06 0403.4.1.A.1-01 STA:1+39.34 OFF: 18.34R 0402.4.1.A.1-06 SSMH 1 0101-01 0501.4.1.B.1-08 0501.4.1.B.1-080501.4.1.B.1-08 L1 L3 0602.4.1.F.1-01 4870.96 TBC-MATCH 0402.4.1.A.1-06 0402.4.1.A.1-060402.4.1.A.1-06 0402.4.1.A.1-06 0402.4.1.A.1-06 4872 4872 SD MH 1 SD CB 2 SD CB 1 SD CB 3 4871.21 TBC-PC 0401.4.1.B.1-886 1+94.51 11.33 R 0401.4.1.B.1-886 2+51.34 11.80 R 0401.4.1.B.1-888 1+45.92 1.001 R 0401.4.1.B.1-886 1+39.42 1.00 R0401.4.1.B.1-886 1+45.92 61.41 R 0401.4.1.B.1-886 3+66.50 12.75 R 0401.4.1.B.1-906 1+45.92 118.26 R 0401.4.1.B.1-8-6 0401.4.1.B.1-888 1+34.40 10.832 R 0401.4.1.B.1-886 3+09.67 12.28 R 4871.53 TBC-PC 4871.47 TBC-PC 0401.4.1.B.1-886 3+86.59 12.92 R 0403.4.1.A.1-01 STA:3+86.59 OFF: 27.50R 0402.4.1.A.1-06 4871.67 TBC-LP 4872.17 TBC-HP CHECK BY SHEETS DRAWN BY JOB NO: DATE: OF SHEET BDJTKP SH E E T N A M E : PR O J E C T : LO C A T I O N : 2020-083 DATE:DATE: September 10, 2020 DA T E RE V I S I O N S CL I E N T : Th e C i v i l C o n n e c t i o n 11 5 0 H o l l i p a r k D r . I d a h o F a l l s , I D 8 3 4 0 1 20 8 . 6 8 1 . 8 5 9 0 PRELIMINARY FOR REVIEW ONLY 5 15 TE T O N R I V E R F L A T S LO R E N E S T R E E T S T A 1 + 0 0 T O 4 + 0 0 RE X B U R G , I D APPROVED BY ________________________DATE:____________ City of REXBURG LORENE STREET PROFILE VIEW LORENE STREET PLAN VIEW 0101-01 RETAIN AND PROTECT EXISTING UTILITY NOTE: 1.CONTRACTOR TO FIELD VERIFY EXISTING UTILITIES LOCATION AND COORDINATE WITH EACH UTILITY LOCATION PRIOR TO CONNECTION PROPOSED UTILITIES. 2.ENSURE 10' MINIMUM CLEARANCE BETWEEN ALL POTABLE AND NON-POTABLE LINES ARE MET PER IDEQ AND CITY OF REXBURG STANDARDS. 3.ENSURE 18'' MINIMUM VERTICAL CLEARANCE BETWEEN ALL POTABLE AND NON-POTABLE LINES ARE MET PER IDEQ AND CITY OF REXBURG STANDARDS 4.SLEEVE POTABLE WATER LINE 10' EITHER SIDE OF CROSSING WITH NON-POTABLE WATER LINE WHERE 18" VERTICAL CLEARANCE IS NOT MET. 0101-02 RETAIN AND PROTECT EXISTING ASPHALT AND CONCRETE 0201.4.1.E.1-01 SAW-CUT LINE AND ASPHALT REMOVAL 0401.4.1.A.1-06 INSTALL 6" WATER PIPE DI C-50 @ 6' MINIMUM COVER 0401.4.1.A.1-08 INSTALL 8" PIPE DI C-50 @ 6' MIN COVER 0401.4.1.B.1-886 INSTALL 8"x8"x6" TEE 0401.4.1.B.1-888 INSTALL 8"x8"x8" TEE 0401.4.1.B.1-906 INSTALL 6" 90° BEND DI C50 0402.4.1.A.1-06 INSTALL 6" WATER VALVE 0402.4.1.A.1-08 INSTALL 8" WATER VALVE 0403.4.1.A.1-01 INSTALL FH ASSEMBLY 0404.4.1.A.1-01 INSTALL 1.25" WATER SERVICE WITH INTERIOR METER 0501.4.1.B.1-08 INSTALL 8" SDR 35 SANITARY SEWER PIPE @ 0.4% 0502.4.1.A.1-01 INSTALL 4' SS MH PER ISPWC SD-501 0504.4.1.B.1-04 INSTALL 4" SDR 35 SANITARY SEWER SERVICE @ 2% MIN TO EASEMENT 0601.4.1.A.17-12 INSTALL 12" ADS N 12 STORM PIPE @ 0.22% MIN. SLOPE 0602.4.1.A.1-01 INSTALL SD MANHOLE PER ISPWC SD-611 0602.4.1.F.1-01 INSTALL CATCH BASIN TYPE I PER ISPWC SD-601 0706.4.1.A.5-01 INSTALL 6" CURB AND GUTTER PER ISPWC SD-701 0706.4.1.A.5-02 INSTALL 6" LIP DOWN CURB AND GUTTER PER DETAIL SHEET 3 0706.4.1.A.5-03 INSTALL 6" HIGH BACK CURB PER REXBURG CITY STANDARDS DESIGN PROFILE @ CL EXISTING SURFACE 0601.4.1.A.17-12 0401.4.1.A.1-08 CITY OF REXBURG INFILTRATOR SYSTEM SEE SHEET 13 0201.4.1.E.1-01 0101-02 0101-02 0706.4.1.E.1-04 0706.4.1.E.1-04 0706.4.1.E.1-04 0706.4.1.A.5-01 0706.4.1.A.5-02 0706.4.1.E.1-04 INSTALL 4" CONCRETE SIDEWALK PER ISPWC SD-709 0404.4.1.A.1-01 0404.4.1.A.1-01 0404.4.1.A.1-01 0404.4.1.A.1-01 0404.4.1.A.1-01 0404.4.1.A.1-01 0504.4.1.B.1-04 0504.4.1.B.1-04 0504.4.1.B.1-04 0504.4.1.B.1-04 0504.4.1.B.1-04 ROAD 1 SHEET 7 LO R E N E S T R E E T SH E E T 6 0401.4.1.A.1-06 0401.4.1.A.1-06 0401.4.1.A.1-06 0401.4.1.A.1-06 0502.4.1.A.1-01 0402.4.1.A.1-08 0402.4.1.A.1-08 0706.4.1.A.5-03 1105.4.1.A.1-01 1105.4.1.A.1-01 INSTALL STOP SIGN AND STREET SIGNS PER MUTCD STD. ENSURE 18" MINIMUM VERTICAL CLEARANCE 0706.4.1.H.1-01 0706.4.1.H.1-01 0706.4.1.A.3-04 0706.4.1.B.3-04 INSTALL VALLEY GUTTER PER ISPWC IF-708A Pipe must be laid flatter. Culinary service can come off fire line if there is capacity. Valve required on culinary line. All manholes must be above flood plain or have bolted lids. DATUM ELEV 4860.00 4864 4868 4872 4876 4+00 48 7 1 . 4 48 7 1 . 3 5 48 7 1 . 5 48 7 1 . 4 8 5+00 48 7 1 . 6 48 7 1 . 5 9 48 7 2 . 5 48 7 2 . 5 0 6+00 48 7 2 . 3 48 7 2 . 2 6 48 7 2 . 8 48 7 2 . 7 7 7+00 48 7 2 . 9 48 7 2 . 8 6 48 7 1 . 4 48 7 1 . 3 5 8+00 48 7 3 . 5 48 7 3 . 5 4 8+50 Install 463' of 8" PVC SDR 35 San. Pipe @ 0 . 4 0 % SSMH 3 Sta:6+07.45 OFF:-12.31L Rim:4872.33 S INV IN:4864.44 E INV IN:4864.44 W INV OUT:4864.34 SD CB 2 Sta:4+09.85 OFF:-24.00L GRATE:4871.26 S INV IN:4868.16 N INV OUT:4868.06 Install 57' of 8" C50 DI Pipe @ 6' Min C o v e r Install 56' of 8" C50 DI Pipe @ 6' Min Cov e r Install 44' of 8" C50 DI Pipe @ 6' Min Cover Install 6' of 8" C50 DI Pipe @ 6' Min Cover 0.60% -0.40% 0.45%PV I S t a . = 4 + 0 9 . 8 5 El e v . = 4 8 7 1 . 6 8 9 PV I S t a . = 6 + 3 2 . 3 7 El e v . = 4 8 7 2 . 6 9 3 PV I S t a . = 7 + 6 4 . 8 3 El e v . = 4 8 7 3 . 4 8 7 PV I S t a . = 8 + 3 4 . 6 0 El e v . = 4 8 7 3 . 2 0 8 Install 61' of 8" C50 DI Pipe @ 6 ' M i n C o v e r Install 60' of 8" C50 DI Pipe @ 6' M i n C o v e r SD MH 1 Sta:5+09.82 OFF:-167.99L Rim:4871.98 S INV IN:4868.05 E INV OUT:4867.95 W INV OUT:4867.95 Install 133' of 8" C50 DI Pip e @ 6 ' M i n C o v e r Install 5' of 8" C50 DI Pipe @ 6' Min Cover Install 6' of 8" C50 DI Pipe @ 6' Min Cover Install 36' of 8" C50 DI Pipe @ 6' Min Cover Install Hydrant Flange: 4873.56' STA: 7+24.87 OFF: 27.49 4+00 5+00 6+00 7+00 8+ 0 0 8+ 4 2 0+ 7 8 1+ 0 0 -2.73% 4872.97 TBC-PI 4872.67 TBC-PC 4871.98 TBC-PC 4871.92 TBC-PC 4872.72 TBC-PC 4872.60 TBC-PC 4871.52 TBC-PI-LP 4871.71 TBC-PC -2.81% - 2 . 4 3 % -2 . 1 3 % BUILDING: B5 AREA: 1,819 SQ FT FF: 4873.75 BUILDING: B6 AREA: 1,819 SQ FT FF: 4874.00 BUILDING:B7 AREA: 1,819 SQ FT FF: 4874.50 BUILDING: D1 AREA: 1,819 SQ FT FF: 4872.50 BUILDING: D2 AREA: 1,819 SQ FT FF: 4872.50 4873.18 TBC-PC 4873.36 TBC-PC 4873.29 EO-PC 4873.23 TBC-MATCH 4873.09 EO-MATCH 4873.12 EO-PC0502.4.1.A.1-01SSMH 3 0501.4.1.B.1-08 0602.4.1.F.1-01 0602.4.1.F.1-01 0402.4.1.A.1-060402.4.1.A.1-06 L2 C1 0402.4.1.A.1-060402.4.1.A.1-06 0402.4.1.A.1-06 4872 4 8 7 2 SD MH 1 SD CB 2 SD CB 1 SD CB 6 0401.4.1.B.1-886 1+44.17 -60.41 L 0401.4.1.B.1-888 1+44.16 10.125 R 0401.4.1.B.1-886 4+23.32 13.22 R 0401.4.1.B.1-886 4+81.57 13.70 R 0401.4.1.B.1-886 5+38.40 14.17 R 0401.4.1.B.1-888 5+89.12 14.593 R 0401.4.1.B.1-906 1+44.17 -117.25 L0401.4.1.B.1-8-6 0401.4.1.B.1-408 7+30.91 18.58 R 0401.4.1.B.1-408 7+78.03 17.53 R 4872.37 TBC-PC -1. 9 6 % 0602.4.1.A.1-01 0401.4.1.B.1-886 7+26.23 16.97 R 0403.4.1.A.1-01 STA:7+24.87 OFF: 27.49R 0402.4.1.A.1-06 0402.4.1.A.1-06 4871.67 TBC-LP 0402.4.1.A.1-08 CHECK BY SHEETS DRAWN BY JOB NO: DATE: OF SHEET BDJTKP SH E E T N A M E : PR O J E C T : LO C A T I O N : 2020-083 DATE:DATE: September 10, 2020 DA T E RE V I S I O N S CL I E N T : Th e C i v i l C o n n e c t i o n 11 5 0 H o l l i p a r k D r . I d a h o F a l l s , I D 8 3 4 0 1 20 8 . 6 8 1 . 8 5 9 0 PRELIMINARY FOR REVIEW ONLY 6 15 TE T O N R I V E R F L A T S LO R E N E S T R E E T S T A 4 + 0 0 T O 8 + 5 0 RE X B U R G , I D APPROVED BY ________________________DATE:____________ City of REXBURG LOREN STREET PROFILE VIEW LORENE STREET PLAN VIEW 0101-01 RETAIN AND PROTECT EXISTING UTILITY NOTE: 1.CONTRACTOR TO FIELD VERIFY EXISTING UTILITIES LOCATION AND COORDINATE WITH EACH UTILITY LOCATION PRIOR TO CONNECTION PROPOSED UTILITIES. 2.ENSURE 10' MINIMUM CLEARANCE BETWEEN ALL POTABLE AND NON-POTABLE LINES ARE MET PER IDEQ AND CITY OF REXBURG STANDARDS. 3.ENSURE 18'' MINIMUM VERTICAL CLEARANCE BETWEEN ALL POTABLE AND NON-POTABLE LINES ARE MET PER IDEQ AND CITY OF REXBURG STANDARDS 4.SLEEVE POTABLE WATER LINE 10' EITHER SIDE OF CROSSING WITH NON-POTABLE WATER LINE WHERE 18" VERTICAL CLEARANCE IS NOT MET. 0101-02 RETAIN AND PROTECT EXISTING ASPHALT AND CONCRETE 0201.4.1.E.1-01 SAW-CUT LINE AND ASPHALT REMOVAL 0401.4.1.A.1-06 INSTALL 6" WATER PIPE DI C-50 @ 6' MINIMUM COVER 0401.4.1.A.1-08 INSTALL 8" PIPE DI C-50 @ 6' MIN COVER 0401.4.1.B.1-886 INSTALL 8"x8"x6" TEE 0401.4.1.B.1-888 INSTALL 8"x8"x8" TEE 0401.4.1.B.1-906 INSTALL 6" 90° BEND DI C50 0402.4.1.A.1-06 INSTALL 6" WATER VALVE 0402.4.1.A.1-08 INSTALL 8" WATER VALVE 0403.4.1.A.1-01 INSTALL FH ASSEMBLY 0404.4.1.A.1-01 INSTALL 1.25" WATER SERVICE WITH INTERIOR METER 0501.4.1.B.1-08 INSTALL 8" SDR 35 SANITARY SEWER PIPE @ 0.4% 0502.4.1.A.1-01 INSTALL 4' SS MH PER ISPWC SD-501 0504.4.1.B.1-04 INSTALL 4" SDR 35 SANITARY SEWER SERVICE @ 2% MIN TO EASEMENT 0601.4.1.A.17-12 INSTALL 12" ADS N 12 STORM PIPE @ 0.22% MIN. SLOPE 0602.4.1.A.1-01 INSTALL SD MANHOLE PER ISPWC SD-611 0602.4.1.F.1-01 INSTALL CATCH BASIN TYPE I PER ISPWC SD-601 0706.4.1.A.5-01 INSTALL 6" CURB AND GUTTER PER ISPWC SD-701 0706.4.1.A.5-02 INSTALL 6" LIP DOWN CURB AND GUTTER PER DETAIL SHEET 3 0706.4.1.A.5-03 INSTALL 6" HIGH BACK CURB PER REXBURG CITY STANDARDS DESIGN PROFILE @CL EXISTING SURFACE CITY OF REXBURG INFILTRATOR SYSTEM SEE SHEET 13 0404.4.1.A.1-01 0404.4.1.A.1-01 0404.4.1.A.1-01 0404.4.1.A.1-01 LO R E N E S T R E E T SH E E T 5 ROAD 2 SHEET 9 0401.4.1.A.1-06 0401.4.1.A.1-06 0401.4.1.A.1-06 0504.4.1.B.1-04 0504.4.1.B.1-04 0504.4.1.B.1-04 0504.4.1.B.1-04 0201.4.1.E.1-01 0706.4.1.A.5-030706.4.1.A.5-03 0706.4.1.E.1-04 0706.4.1.E.1-04 0402.4.1.A.1-08 0402.4.1.A.1-08 0404.4.1.A.1-01 1105.4.1.A.1-01 0706.4.1.E.1-04 INSTALL 4" CONCRETE SIDEWALK PER ISPWC SD-709 1105.4.1.A.1-01 INSTALL STOP SIGN AND STREET SIGNS PER MUTCD STD. 0602.4.1.F.1-01 0101-02 0101-01 ENSURE 18" MINIMUM VERTICAL CLEARANCE 0402.4.1.A.1-08 0706.4.1.H.1-01 INSTALL ADA PEDESTRIAN RAMP W/DETECTABLE WARNING DOMES PER ISPWC SD-712 0706.4.1.H.1-01 0706.4.1.H.1-01 0706.4.1.B.3-04 Sanitary Sewer line to be extnded to intersection to the East. Water line to have tee and valves for future. Manholes not in street must be 24" above surrounding ground level. DATUM ELEV 4862.00 4864 4868 4872 4876 4+50 48 7 1 . 8 48 7 1 . 7 7 5+00 48 7 1 . 7 48 7 1 . 6 7 6+00 48 7 1 . 4 48 7 1 . 4 3 6+25 Install 199' of 12" ADS N 12 Storm Pipe @ 0.22% Install 130' of 8" ADS N 12 S t o r m P i p e @ 0 . 6 0 % SSMH 7 Sta:5+60.37 OFF:-4.49L GRATE:4871.36 E INV OUT:4866.85 SD CB 8 Sta:6+08.05 OFF:-29.01L GRATE:4870.52 E INV IN:4867.04 N INV OUT:4866.94 SD MH 3 Sta:6+08.95 OFF:-9.41L GRATE:4871.05 S INV IN:4866.89 Install Hydrant Flange: 4872.76' STA: ??? OFF: ??? Install 9' of 6" C50 DI Pipe @ 6' Min Cover Install 10' of 6" C50 DI Pipe @ 6' Min Cover 3+ 0 0 4+ 0 0 5+006+006+14 -2.00% -2 . 3 4 % -2 . 8 7 % -0.40% -0 . 4 0 % 4872.95 TBC-PI 4872.95 TBC-PI BUILDING: C3 AREA: 1,819 SQ FT FF: 4873.25 BUILDING: C4 AREA: 1,819 SQ FT FF: 4874.00 BUILDING: C2 AREA: 1,819 SQ FT FF: 4873.75 BUILDING: D9 AREA: 1,819 SQ FT FF: 4872.50 BUILDING: D10 AREA: 1,819 SQ FT FF: 4872.50 BUILDING: D8 AREA: 1,819 SQ FT FF: 4872.75 BUILDING: D7 AREA: 1,819 SQ FT FF: 4872.75 BUILDING: D5 AREA: 1,819 SQ FT FF: 4873.00 BUILDING: D6 AREA: 1,819 SQ FT FF: 4873.00 0401.4.1.A.1-08 SSMH 6 SSMH 7 0501.4.1.B.1-08 0501.4.1.B.1-08 0402.4.1.A.1-06 0402.4.1.A.1-06 0403.4.1.A.1-01 STA:4+70.79 OFF: 16.50R 0402.4.1.A.1-06 0402.4.1.A.1-06 0602.4.1.F.1-01 0402.4.1.A.1-06 0402.4.1.A.1-06 4872.71 TBC-PC 4872.67 TBC-PC 4872.67 TBC-PC 4872.67 TBC-PC 4872.71 TBC-PC 4871.50 TBC-PI-LP 4871.79 TBC-PC 4871.79 TBC-PC 4871.72 TBC-PI0601.4.1.A.17-12 0602.4.1.F.1-01 0602.4.1.A.1-01 L6 4871 SD CB 7 SD CB 8 SD MH 3 0401.4.1.B.1-888 3+43.09 10.988 R 0401.4.1.B.1-886 4+50.13 8.42 R 0401.4.1.B.1-886 3+76.90 11.13 R 0401.4.1.B.1-886 0401.4.1.B.1-886 3+43.09 -60.41 L 0401.4.1.B.1-886 6+01.38 118.80 R 0401.4.1.B.1-886 3+20.07 10.89 R 0401.4.1.B.1-8-6 0401.4.1.B.1-906 5+36.76 137.35 R 0401.4.1.B.1-8-6 0401.4.1.B.1-9060401.4.1.B.1-908 STA: 4+50.30 OFF: -26.600 L 0401.4.1.B.1-906 4+70.78 8.42 R 0401.4.1.B.1-8-6 0401.4.1.B.1-906 3+43.09 -117.25 L 0402.4.1.A.1-06 0402.4.1.A.1-06 4872.50 TBC-PI 4871.97 TBC-PC 4871.72 TBC-PC 4871.02 TBC-PI 4872.26 TBC-PC 4872.20 TBC-PC 4871.23 TBC-PC 4871.47 TBC-PC 4871.39 TBC-MATCH 4871.69 TBC-MATCH 4871.65 TBC-LP 4871.42 TBC -0 . 6 4 % -2 . 0 3 % 4872 0402.4.1.A.1-08 0402.4.1.A.1-06 BUILDING: C1 AREA: 1,819 SQ FT FF: 4873.50 CHECK BY SHEETS DRAWN BY JOB NO: DATE: OF SHEET BDJTKP SH E E T N A M E : PR O J E C T : LO C A T I O N : 2020-083 DATE:DATE: September 10, 2020 DA T E RE V I S I O N S CL I E N T : Th e C i v i l C o n n e c t i o n 11 5 0 H o l l i p a r k D r . I d a h o F a l l s , I D 8 3 4 0 1 20 8 . 6 8 1 . 8 5 9 0 PRELIMINARY FOR REVIEW ONLY 10 15 TE T O N R I V E R F L A T S DR I V E 2 4 + 5 0 T O 6 + 2 5 RE X B U R G , I D APPROVED BY ________________________DATE:____________ City of REXBURG DRIVE 2 PROFILE VIEW DRIVE 2 PLAN VIEW NOTE: 1.CONTRACTOR TO FIELD VERIFY EXISTING UTILITIES LOCATION AND COORDINATE WITH EACH UTILITY LOCATION PRIOR TO CONNECTION PROPOSED UTILITIES. 2.ENSURE 10' MINIMUM CLEARANCE BETWEEN ALL POTABLE AND NON-POTABLE LINES ARE MET PER IDEQ AND CITY OF REXBURG STANDARDS. 3.ENSURE 18'' MINIMUM VERTICAL CLEARANCE BETWEEN ALL POTABLE AND NON-POTABLE LINES ARE MET PER IDEQ AND CITY OF REXBURG STANDARDS 4.SLEEVE POTABLE WATER LINE 10' EITHER SIDE OF CROSSING WITH NON-POTABLE WATER LINE WHERE 18" VERTICAL CLEARANCE IS NOT MET. 0401.4.1.A.1-06 INSTALL 6" WATER PIPE DI C-50 @ 6' MINIMUM COVER 0401.4.1.A.1-08 INSTALL 8" PIPE DI C-50 @ 6' MIN COVER 0401.4.1.B.1-886 INSTALL 8"x8"x6" TEE 0401.4.1.B.1-888 INSTALL 8"x8"x8" TEE 0401.4.1.B.1-906 INSTALL 6" 90° BEND DI C50 0402.4.1.A.1-06 INSTALL 6" WATER VALVE 0402.4.1.A.1-08 INSTALL 8" WATER VALVE 0403.4.1.A.1-01 INSTALL FH ASSEMBLY 0404.4.1.A.1-01 INSTALL 1.25" WATER SERVICE WITH INTERIOR METER 0501.4.1.B.1-08 INSTALL 8" SDR 35 SANITARY SEWER PIPE @ 0.4% 0502.4.1.A.1-01 INSTALL 4' SS MH PER ISPWC SD-501 0504.4.1.B.1-04 INSTALL 4" SDR 35 SANITARY SEWER SERVICE @ 2% MIN TO EASEMENT 0601.4.1.A.17-12 INSTALL 12" ADS N 12 STORM PIPE @ 0.22% MIN. SLOPE 0602.4.1.A.1-01 INSTALL SD MANHOLE PER ISPWC SD-611 0602.4.1.F.1-01 INSTALL CATCH BASIN TYPE I PER ISPWC SD-601 0706.4.1.A.5-01 INSTALL 6" CURB AND GUTTER PER ISPWC SD-701 0706.4.1.A.5-02 INSTALL 6" LIP DOWN CURB AND GUTTER PER DETAIL SHEET 3 0706.4.1.E.1-04 INSTALL 4" CONCRETE SIDEWALK PER ISPWC SD-709 DESIGN PROFILE @ CL EXISTING SURFACE 10'X 10' CONCRETE DUMPSTER PAD STORM TECH CHAMBER 2 SEE SHEET 11 0404.4.1.A.1-01 0404.4.1.A.1-01 0101-01 0504.4.1.B.1-04 0706.4.1.E.1-04 0706.4.1.E.1-04 0706.4.1.E.1-04 0706.4.1.E.1-04 0504.4.1.B.1-04 0404.4.1.A.1-01 0404.4.1.A.1-01 0404.4.1.A.1-01 0504.4.1.B.1-04 0504.4.1.B.1-04 0504.4.1.B.1-04 0504.4.1.B.1-04 0706.4.1.E.1-04 0706.4.1.A.5-02 0706.4.1.A.5-01 0706.4.1.H.1-01 0706.4.1.A.5-01 0706.4.1.A.5-02 ROAD 2 SHEET 9 0502.4.1.A.1-01 0502.4.1.A.1-01 0706.4.1.H.1-01 INSTALL ADA PEDESTRIAN RAMP W/DETECTABLE WARNING DOMES PER ISPWC SD-712 0706.4.1.A.5-02 0706.4.1.B.3-04 0706.4.1.B.3-04 INSTALL VALLEY GUTTER PER ISPWC IF-708A SEE NOTE 4 0404.4.1.A.1-01 0404.4.1.A.1-01 0404.4.1.A.1-01 Trash Enclosure pads are too small per City Standards.