HomeMy WebLinkAboutVERTICAL TURBINE PUMP ACCESSORIES - 23-00006 - Hibbard Elemenatry - Fire Sprinkler SUBMITTAL DATA VERTICAL TURBINE FIRE PUMP ACCESSORIES 500 GPM @ 95 PSI BOOST PHOENIX FIRE PROTECTION HIBBARD ELEMENTARY REXBURG, IDAHO General ArrangementABCD4.002.008.502.50EFGHJ2.503.502.759.5011.00NOTES:1. Dimensions are in inches (mm) and may vary ±1/4 (6).2. Components shown are shipped loose for field installation and assembly.3. Manifold supply size “A” and the number of hose valves (“B”) meets or exceedsthe minimums specified by N.F.P.A. 20 for the pump ratings indicated.4. Manifolds for 3000 through 5000 GPM ratings consist of multiple sectionsandmay require support (by others).5. 1-1/2” Hose valves furnished with 1-1/2” National Standard Fire Hose Thread: 1.9900 (50.55) O.D. (max.), 6 threads per inch. 2-1/2” Hose valves are furnished with 2-1/2” National Standard Fire HoseThread: 3.0686 (77.94) O.D. (max.), 7-1/2 threads per inch. Refer to factory for other thread conventions or adaptors.Quote InformationCustomerNICKERSON COMPANY, INC. - UT (AuroraCustomer Quote0Job NameMarket-Quote Item001Quote Date22 Jul 2022Encompass 2.0 - 22.2.0 AURORA® FIRE PUMPS OPTION 75 - TEST MANIFOLD OPTION 76 - HOSE VALVES OPTION 77 - BALL DRIP VALVE Section 916 Page 203 Date September 2013 Supersedes Section 916 Page 203 Dated May 2004 VALVE SIZE ”E“ ”F“ ”G“ ”H“ ”J“ 1-1/2 2.25 2.00 6.50 7.50 (57) (51) (165) (191) 2-1/2 3.5 2.75 9.50 11.00 (89) (70) (241) (297) NOTES: 1. Dimensions are in inches (mm) and may vary ±1/4 (6). 2. Components shown are shipped loose for field installation and assembly. 3. Manifold supply size “A” and the number of hose valves (“B”) meets or exceeds the minimums specified by N.F.P.A. 20 for the pump ratings indicated. 4. Manifolds for 3000 through 5000 GPM ratings consist of multiple sections and may require support (by others). 5. 1-1/2” Hose valves furnished with 1-1/2” National Standard Fire Hose Thread: 1.9900 (50.55) O.D. (max.), 6 threads per inch. 2-1/2” Hose valves are furnished with 2-1/2” National Standard Fire Hose Thread: 3.0686 (77.94) O.D. (max.), 7-1/2 threads per inch. Refer to factory for other thread conventions or adaptors. STD. 125# ASA FLANGES OPT. 250# ASA FLANGES OPTION 75 - TEST MANIFOLD WITH CAPS AND CHAINS WITHOUT CAPS AND CHAINS OPTION 76 - HOSE VALVE(S) Designed to drain a branch line leading to an outside test manifold where danger of freezing exists. Opens at zero flow. OPTION 77 - BALL DRIP VALVE "E" NPT "J"OPEN "H"CLOSED "E" HOSE THREAD (SEE NOTE 5) "G" "F" LISTED APPROVED FM QTY "B" SIZE "D" PIPE TAPS FOR HOSE VA LVES A C 2.56 (65) 1/2 NPT 100 400 1250 PUMP RATING 50 150 250 450 750 1000 1500 2500 3000 3500 4000 5000 G.P.M. 200 300 500 2000 4500 ”A“ MANIFOLD SUPPLY SIZE 1.5” 2.5” 3” 4” 6” 6” 8” 10” 10” 12” 12” 12” ”B“ 1 1 1 2 3 4 6 8 12 12 16 20 ”C“ 1.00 1.13 1.31 8.50 10.62 10.62 11.75 12.50 25.63 31.63 31.63 43.75 (25) (29) (33) (216) (270) (270) (298) (318) (651) (803) (803) (1111) ”D“ 1-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 Well Service Air Valves MATERIALS OF CONSTRUCTION COMPONENT STANDARD OPTIONAL Body and Cover Cast Iron ASTM A126 Class B Class 125 and 250 Ductile Iron ASTM A536 Grade 65-45-12 Stainless Steel ASTM A351 Grade CF8M Trim Type 316 Stainless Steel (Air Valve) Bronze ASTM B584 C83600 (Reg. Exh. Dev.)*- Coating Universal Alkyd Primer (external)Non-Stick Fusion Bonded Epoxy (internal & external) WELL SERVICE AIR VALVE SIZING VALVE SIZE NO HEAD PUMP CAPACITY, GPM MODEL NUMBER 150 PSI MODEL 300 PSI MODEL 1/2”0 - 350 100ST 1”351 - 1,350 101ST 2”1,351 - 4,000 102ST 3”4,001 - 7,000 103ST 4”7,001 - 11,000 104SS 154SS 6”11,001 - 24,000 106SS 156SS 8”24,001 - 50,000 108SS 158SS 10”50,001 - 70,000 110FSS 160FSS 12”70,001 - 110,000 112FSS 162FSS 22 Operational Highlights: • Regulates the exhaust of air on pump start-up • Admits air to protect pump and mechanical seals • Protects against air-related surges on pump start-up • Fully complies with AWWA C512 and NSF 61 Product Features: • Unconditionally guaranteed 316 stainless steel floats • Inlets and outlets are equal to full nominal pipe area • 1/2" - 3" equipped with Dual Port Throttling Device • 4" and larger equipped with Regulated-Exhaust Device mounted on the inlet Dual Port Throttling Device: • Adjustable discharge outlet provides regulated air exhaust • Allows air to enter the system on pump shut down through an unrestricted independent vacuum port Regulated-Exhaust Device: • Retrictor disc provides regulated exhaust to limit pump column surges • Ability to adjust air exhaust for greater surge suppression • Provides full vacuum flow port 1 - 3 inch 4 inch & larger *(Reg. Exh. Dev.) = Regulated-Exhaust Device Well Service Air Valve with Dual Port Throttling Device Inlet Size Outlet Size Model Number CWP PSI Dimensions A B 1/2” NPT 1/2” NPT 100ST 300 6 1/8”11 3/4” 1” NPT 1” NPT 101ST 300 7”14 3/4” 2” NPT 2” NPT 102ST*300 9 1/2”20 1/8” 3” NPT 3” NPT 103ST*300 9 1/2”22 1/8” Well Service Air Valve with Regulated-Exhaust Device Inlet Size Outlet Size Model Number CWP PSI Dimensions A B 4” 125lb Flg 4” NPT 104SS 150 11 1/2”22 3/4” 4” 250lb Flg 4” NPT 154SS 300 11 1/2”22 3/4” 6” 125lb Flg 6” NPT 106SS 150 14”28 1/2” 6” 250lb Flg 6” NPT 156SS 300 14”28 1/2” 8” 125lb Flg 8” NPT 108SS 150 17 1/4”35 5/16” 8” 250lb Flg 8” NPT 158SS 300 17 1/4”35 5/16” 10” 125lb Flg 10” 125lb Flg 110FSS 150 20 1/4”40 1/16” 10” 250lb Flg 10” 125lb Flg 160FSS 300 20 1/4”40 1/16” 12” 125lb Flg 12” 125lb Flg 112FSS 150 24”44 5/16” 12” 250lb Flg 12” 125lb Flg 162FSS 300 24”44 5/16” *UL Listed for fire pump service Installation Dimensions A B 100ST - 103ST Well Service Air Valves with Dual Port Throttling Device 104SS - 162FSS Well Service Air Valves with Regulated-Exhaust Device A B 23 Well Service Air Valves 3” Well Service Air Valve on Vertical Pump discharge.