HomeMy WebLinkAboutSUBMERSIBLE JOCKEY PUMP - 23-00006 - Hibbard Elemenatry - Fire Sprinkler SUBMITTAL DATA SUBMERSIBLE JOCKEY PUMP AND JOCKEY CONTROLLER 5 GPM @ 105 PSI BOOST PHOENIX FIRE PROTECTION HIBBARD ELEMENTARY REXBURG, IDAHO STA-RITE® HS Series Stainless Steel Signature 2000® 5 and 7 gpm TrimLine™ 4" submersible pumps Features Proven staging system: Our proven SignaSeal staging system incorpo rates a harder-than-sand ceramic wear surface that when incorporated with our floating impeller design, greatly reduces problems with abrasives, sand lock-up and running dry. Discharge: Corrosion-resistant 300 grade stainless steel for durability in aggressive water. Large octagon wrench area for ease of installation. Discharge Bearing: Exclusive self- lubricating Nylatron bearing resists wear from sand. Intake: Corrosion-resistant 300 grade stainless steel for durability in aggressive water. shaft: Positive drive from 7/16" hex agonal heavy-duty 300 grade stainless steel. Coupling: Stainless steel press fit to pump shaft. Couples to all standard NEMA motors. shell: Heavy-walled corrosion-resistant 300 grade stainless steel. Threaded for easy servicing. Hardware: All screws, washers and nuts are corrosion-resistant 300 grade stainless steel. Check Valve: Durable internal spring- loaded check valve. Cable Guard: Corrosion-resistant stainless steel guard protects motor leads. Tapered ends prevent pump from catching on well. Intake screen: Corrosion-proof stainless steel. Pentek® Xe series™ Motor: 2 and 3 wire NEMA standard all stainless construction water-filled motors. Precision-engineered, high-quality, rugged signature 2000® stainless steel series Pumps deliver efficient, dependable performance even in rough, aggressive water. the trimLine™ 5 and 7 GPM series Pumps are 3-3/4" maximum O.D. Heads to 1,150 feet and capacities to 10.5 GPM. Built to deliver long-term, trouble-free service. Floating impeller design resists sand and reduces sand locking. these pumps feature the proven signaseal™ staging system. aPPLICatIONs Water systems…for residential, industrial, commercial, multiple housing and farm use. sPeCIFICatIONs shell: Stainless steel Discharge: Stainless steel Discharge Bearing: Nylatron® Intermediate Bearing: (On larger units) polycarbonate, nitrile rubber and stainless steel Impellers: Acetal Diffusers: Polycarbonate suction Caps: Polycarbonate with stainless steel insert thrust Pads: Proprietary spec. shaft and Coupling: Stainless steel Intake: Stainless steel Intake screen: Stainless steel Cable Guard: Stainless steel agency Listings: CSA Check Valve: Acetal Nylatron® is a registered trademark of Polymer Corp. All other brand or product names are trademarks or registered trademarks of Pentair Ltd. 1 S4556wS STA-RITE® HS Series Stainless Steel Signature 2000® 5 and 7 gpm TrimLine™ 4" submersible pumps OrDerING INFOrMatION GPM MOtOr tyPe HP stGs.PH V OLt asseMBLeD PuMP PuMP eND MOtOr CONtrOL BOX Cata LOG NuMBer LeNGtH IN.*WeIGHt LBs.*Cata LOG NuMBer LeNGtH IN.*WeIGHt LBs.*Cata LOG NuMBer WeIGHt LBs.*Cata LOG NuMBer WeIGHt LBs.* 5 2 WIre 1/2 13 1 115 S5P4HS05121 27-1/2 28 L5P4CHL 18 12 P42B0005A1 19 1/2 13 1 230 S5P4HS05221 27-1/2 28 L5P4CHL 18 12 P42B0005A2 19 3/4 18 1 230 S5P4HS07221 32-3/4 34 L5P4DHL 22 15 P42B0007A2 23 1 22 1 230 S5P4HS10221 37 39 L5P4EHL 25-1/4 17 P42B0010A2 25 1-1/2 30 1 230 S5P4HS15221 47 51 L5P4FHL 32 21 P42B0015A2 29 3 WIre 1/2 13 1 115 S5P4HS05131 27-1/2 28 L5P4CHL 18 12 P43B0005A1 19 SMC-IR0511 4 1/2 13 1 230 S5P4HS05231 27-1/2 28 L5P4CHL 18 12 P43B0005A2 18 SMC-CR0521 4 3/4 18 1 230 S5P4HS07231 32-3/4 34 L5P4DHL 22 15 P43B0007A2 21 SMC-CR0721 4 1 22 1 230 S5P4HS10231 37 39 L5P4EHL 25-1/4 17 P43B0010A2 23 SMC-CR1021 4 1-1/2 30 1 230 S5P4HS15231 45-1/2 48 L5P4FHL 32 21 P43B0015A2 27 SMC-CR1521 7 1-1/2 30 3 230 L5P4FHL 32 21 P43B0015A3 23 1-1/2 30 3 460 L5P4FHL 32 21 P43B0015A4 23 2 38 1 230 L5P4GHL 37-3/4 25 P43B0020A2 31 SMC-CR2021 7 2 38 3 230 L5P4GHL 37-3/4 25 P43B0020A3 23 2 38 3 460 L5P4GHL 37-3/4 25 P43B0020A4 23 7 2 WIre 1/2 10 1 115 S7P4HS05121 25-1/2 27 L7P4CHL 16 11 P42B0005A1 19 1/2 10 1 230 S7P4HS05221 25-1/2 27 L7P4CHL 16 11 P42B0005A2 19 3/4 13 1 230 S7P4HS07221 29 32 L7P4DHL 18-1/2 13 P42B0007A2 23 1 17 1 230 S7P4HS10221 33-3/4 37 L7P4EHL 22 15 P42B0010A2 25 1-1/2 22 1 230 S7P4HS15221 42-1/2 47 L7P4FHL 27-1/4 17 P42B0015A2 29 3 WIre 1/2 10 1 115 S7P4HS05131 25-1/2 27 L7P4CHL 16 11 P43B0005A1 19 SMC-IR0511 4 1/2 10 1 230 S7P4HS05231 25-1/2 27 L7P4CHL 16 11 P43B0005A2 18 SMC-CR0521 4 3/4 13 1 230 S7P4HS07231 29 32 L7P4DHL 18-1/2 13 P43B0007A2 21 SMC-CR0721 4 1 17 1 230 S7P4HS10231 33-3/4 37 L7P4EHL 22 15 P43B0010A2 23 SMC-CR1021 4 1-1/2 22 1 230 S7P4HS15231 41 44 L7P4FHL 27-1/4 17 P43B0015A2 27 SMC-CR1521 7 1-1/2 22 3 230 L7P4FHL 27-1/4 17 P43B0015A3 23 1-1/2 22 3 460 L7P4FHL 27-1/4 17 P43B0015A4 23 2 28 1 230 L7P4GHL 32-1/2 20 P43B0020A2 31 SMC-CR2021 7 2 28 3 230 L7P4GHL 32-1/2 20 P43B0020A3 27 2 28 3 460 L7P4GHL 32-1/2 20 P43B0020A4 27 3 36 1 230 L7P4HHL 39-1/2 24 P43B0030A2 37 SMC-CR3021 8 3 36 3 230 L7P4HHL 39-1/2 24 P43B0030A3 37 3 36 3 460 L7P4HHL 39-1/2 24 P43B0030A4 37 *Length and weight are approximate. TrimLine™ version maximum outside diameter is 3-3/4". Standard version maximum outside diameter is 3-7/8". NOTE: Motor, Control Box or Magnetic Starter must be ordered separately, if ordering pump end only. Discharge NPT is 1-1/4". 2 S4556wS STA-RITE® HS Series Stainless Steel Signature 2000® 5 and 7 gpm TrimLine™ 4" submersible pumps 3-3/4 Pump EndAssembled PumpFor dimensions, refer to Ordering Information table. Dimensions (in inches) are for estimating purposes only.TOTAL HEAD IN FEETCAPACITY GALLONS PER MINUTE 1200 1000 800 600 400 200 02468 1-1/2 H P 1 HP 3/4 HP 1/2 HP 350 300 250 200 150 100 50 0 CAPACITY LITERS PER MINUTE TOTAL HEAD IN METERS15 25 30105020 2 H P Tested and rated in accordance with water Systems Council Standards. NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure. CAPACITY GALLONS PER MINUTE 0246 10 1-1/2 HP 1 HP 3/4 HP 1/2 HP 200 400 600 800 1000 1200 8 2 HP 3 HP 12TOTAL HEAD IN FEET350 300 250 200 150 100 50 0 CAPACITY LITERS PER MINUTE TOTAL HEAD IN METERS30 4010020 OutLINe DIMeNsIONs PuMP PerFOrMaNCe: 5 GPM PuMP PerFOrMaNCe: 7 GPM DIsCHarGe 5 GPM 1-1/4" NPT 7 GPM 1-1/4" NPT 3 S4556wS STA-RITE® HS Series Stainless Steel Signature 2000® 5 and 7 gpm TrimLine™ 4" submersible pumps CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty is void when failure occurs under these conditions. Tested and rated in accordance with water Systems Council Standards. NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure. 5 GaLLONs Per MINute PuMP PerFOrMaNCe (CapaCity in Gallons per Minute) HP PsI PuMPING DePtH IN Feet sHut-OFF HeaD 20 40 60 80 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 Feet PsI 1/2 0 –––––7.4 7.2 7.0 6.7 5.7 4.3 2.7 380 164 20 –––7.4 7.3 7.0 6.7 6.3 5.7 4.5 2.8 30 ––7.4 7.2 7.1 6.8 6.3 5.8 5.2 3.6 1.5 40 –7.4 7.2 7.0 6.8 6.4 5.8 5.3 4.6 2.9 50 7.3 7.2 7.0 6.7 6.4 5.9 5.3 4.7 3.7 1.7 60 7.2 6.9 6.7 6.3 5.9 5.3 4.7 3.8 3.0 3/4 0 –––––––7.4 7.3 6.9 6.4 5.6 4.7 3.4 2.0 531 230 20 –––––7.4 7.3 7.1 6.9 6.5 5.7 4.8 3.5 2.2 30 ––––7.4 7.3 7.1 7.0 6.7 6.1 5.3 4.2 3.0 1.1 40 –––7.4 7.3 7.2 7.0 6.8 6.5 5.7 4.9 3.6 2.4 50 ––7.4 7.3 7.2 7.0 6.8 6.5 6.2 5.4 4.3 3.1 1.3 60 7.5 7.4 7.3 7.1 7.0 6.8 6.5 6.2 5.8 4.9 3.6 2.4 1 0 ––––––––7.5 7.2 7.0 6.5 6.0 5.3 4.5 3.4 2.4 652 282 20 ––––––7.5 7.4 7.2 7.0 6.6 6.0 5.3 4.5 3.5 2.5 30 –––––7.5 7.4 7.3 7.2 6.9 6.3 5.8 5.1 4.1 3.1 1.7 40 ––––7.5 7.4 7.3 7.2 7.0 6.7 6.1 5.4 4.6 3.6 2.6 0.3 50 –––7.5 7.4 7.3 7.2 7.0 6.9 6.4 5.8 5.1 4.1 3.1 1.9 60 ––7.5 7.4 7.3 7.2 7.0 6.9 6.7 6.1 5.5 4.7 3.6 2.7 0.7 1-1/2 0 ––––––––––7.4 7.2 7.0 6.7 6.4 5.9 5.5 4.9 4.1 3.4 2.7 1.6 882 382 20 –––––––––7.4 7.2 7.0 6.8 6.4 6.0 5.5 5.0 4.2 3.5 2.8 1.7 30 ––––––––7.5 7.3 7.1 6.9 6.6 6.2 5.7 5.3 4.6 3.8 3.2 2.4 0.7 40 –––––––7.5 7.4 7.2 7.1 6.8 6.4 6.0 5.6 5.0 4.3 3.6 2.8 1.8 50 ––––––7.5 7.4 7.3 7.1 6.9 6.6 6.2 5.8 5.3 4.7 3.9 3.2 2.5 1.1 60 –––––7.5 7.4 7.3 7.2 7.1 6.8 6.5 6.0 5.6 5.0 4.3 3.6 2.9 1.8 2 0 ––––––––––––––7.0 6.8 6.5 6.2 5.9 5.5 5.0 4.5 4.0 3.3 2.4 1.5 1120 485 20 –––––––––––––7.0 6.8 6.5 6.2 5.9 5.5 5.0 4.5 4.0 3.3 2.4 1.5 30 ––––––––––––7.2 6.9 6.6 6.3 6.0 5.7 5.2 4.8 4.3 3.7 2.9 2.1 1.1 40 –––––––––––7.3 7.0 6.8 6.5 6.2 5.9 5.5 5.0 4.5 4.0 3.3 2.4 1.5 50 ––––––––––7.4 7.2 6.9 6.6 6.4 6.1 5.8 5.4 4.9 4.4 3.9 3.1 2.2 1.2 60 ––––––––––7.3 7.1 6.8 6.5 6.2 6.0 5.6 5.1 4.6 4.1 3.2 2.5 1.6 4 S4556wS STA-RITE® HS Series Stainless Steel Signature 2000® 5 and 7 gpm TrimLine™ 4" submersible pumps CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty is void when failure occurs under these conditions. Tested and rated in accordance with water Systems Council Standards. NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure. 7 GaLLONs Per MINute PuMP PerFOrMaNCe (CapaCity in Gallons per Minute) HP PsI PuMPING DePtH IN Feet sHut-OFF HeaD 20 40 60 80 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 Feet PsI 1/2 0 –11.0 10.4 9.9 9.5 9.0 8.6 8.1 7.5 5.7 3.2 322 139 20 10.2 9.2 9.3 8.9 8.6 8.1 7.6 6.7 5.4 3.6 30 9.7 9.3 8.9 8.6 8.1 7.6 6.8 5.9 5.0 40 9.2 8.9 8.5 8.1 7.6 7.0 6.0 5.0 3.6 50 8.8 8.5 8.0 7.6 7.0 6.0 5.1 3.9 60 8.4 8.0 7.5 6.8 6.2 5.1 4.0 3/4 0 ––11.0 10.4 9.9 9.5 9.2 8.9 8.5 7.6 6.5 5.0 2.3 409 177 20 10.7 10.2 9.9 9.5 9.3 8.9 8.6 8.2 7.7 6.5 5.2 3.0 30 10.1 9.8 9.4 9.2 8.9 8.6 8.2 7.8 7.2 6.0 4.2 40 9.7 9.4 9.1 8.9 8.7 8.3 7.9 7.3 6.7 5.2 3.1 50 9.4 9.1 8.9 8.6 8.3 7.9 7.3 6.7 6.1 4.3 60 9.0 8.8 8.5 8.2 7.9 7.4 6.7 6.1 5.4 3.1 1 0 –––10.8 10.4 10.0 9.7 9.4 9.1 8.6 8.0 7.3 6.4 5.2 3.7 545 236 20 –10.6 10.3 10.0 9.8 9.4 9.2 8.9 8.6 8.1 7.3 6.5 5.3 3.8 30 10.5 10.2 9.9 9.7 9.4 9.2 8.9 8.6 8.4 7.7 6.9 6.0 4.6 2.8 40 10.2 9.9 9.7 9.4 9.2 9.0 8.6 8.4 8.1 7.4 6.5 5.3 3.9 50 9.9 9.6 9.3 9.2 9.0 8.6 8.4 8.2 7.8 7.0 6.1 5.3 3.0 60 9.5 9.3 9.2 8.9 8.7 8.4 8.2 7.8 7.5 6.6 5.5 4.0 1-1/2 0 ––––10.9 10.4 10.1 9.9 9.7 9.2 8.8 8.4 7.9 7.3 6.6 5.8 4.8 3.5 705 305 20 ––10.7 10.4 10.2 9.9 9.7 9.4 9.2 8.8 8.5 8.0 7.3 6.7 5.8 4.9 3.7 30 11.0 10.7 10.4 10.2 9.9 9.3 9.5 9.2 9.0 8.7 8.2 7.7 7.1 6.3 5.9 4.4 2.7 40 10.6 10.3 10.2 9.9 9.7 9.5 9.2 9.1 8.8 8.5 8.0 7.4 6.7 5.9 4.9 3.7 50 10.3 10.1 9.9 9.7 9.5 9.2 9.1 8.8 8.7 8.3 7.7 7.1 6.5 5.4 4.6 2.8 60 10.1 9.8 9.7 9.5 9.3 9.1 8.9 8.7 8.5 8.0 7.5 6.8 6.0 5.0 4.1 2 0 –––––10.9 10.6 10.3 10.1 9.7 9.4 9.0 8.7 8.4 8.0 7.4 7.1 6.4 5.8 5.0 4.2 2.8 900 389 20 –––10.8 10.6 10.4 10.1 10.0 9.7 9.4 9.1 8.7 8.4 8.0 7.6 7.1 6.6 5.8 5.1 4.3 3.8 30 –11.0 10.7 10.6 10.4 10.1 10.0 9.7 9.5 9.2 8.9 8.6 8.3 7.9 7.4 6.9 6.2 5.5 4.7 3.8 40 10.9 10.7 10.5 10.4 10.2 10.0 9.8 9.6 9.4 9.1 8.7 8.5 8.1 7.7 7.2 6.6 5.9 5.2 4.2 3.2 50 10.7 10.5 10.3 10.1 10.0 9.8 9.6 9.4 9.3 8.9 8.7 8.3 7.9 7.4 6.9 6.3 5.5 4.8 4.0 2.3 60 10.4 10.3 10.1 10.0 9.8 9.6 9.4 9.3 9.1 8.8 8.5 8.1 7.7 7.2 6.7 6.0 5.8 4.5 3.3 3 0 –––––––10.8 10.5 10.1 9.9 9.5 9.3 9.0 8.8 8.6 8.3 8.0 7.6 7.3 6.8 6.4 5.7 5.2 4.7 3.9 2.5 1150 498 20 –––––10.9 10.6 10.4 10.2 9.9 9.5 9.3 9.0 8.8 8.6 8.3 8.1 7.7 7.4 6.9 6.5 5.8 5.2 4.8 4.0 3.1 30 ––––10.9 10.6 10.4 10.2 10.0 9.6 9.4 9.2 8.9 8.7 8.4 8.1 7.9 7.4 7.0 6.6 6.0 5.4 5.8 4.3 3.5 40 –––10.9 10.7 10.4 10.3 10.0 10.0 9.6 9.4 9.1 8.8 8.6 8.3 8.1 7.8 7.4 7.0 6.5 5.9 5.3 4.9 4.2 3.2 50 –11.0 10.8 10.6 10.4 10.3 10.0 10.0 9.7 9.4 9.2 8.9 8.7 8.5 8.1 7.9 7.5 7.1 6.6 6.1 5.5 5.1 4.4 3.6 60 11.0 10.7 10.6 10.4 10.3 10.0 10.0 9.7 9.6 9.4 9.1 8.9 8.7 8.4 8.1 7.8 7.4 7.0 6.6 5.9 5.3 4.9 4.2 3.3 5 S4556wS STA-RITE® HS Series Stainless Steel Signature 2000® 5 and 7 gpm TrimLine™ 4" submersible pumps 6 S4556wS Publication SBP560F Rev. C (DRAWINGS INCLUDED IN THIS PACKAGE ARE FOR STANDARD CONTROLLERS. ACTUAL “AS BUILT” DRAWINGS MAY DIFFER Submittal Package Limited Option Jockey Pump Controller FTA560F FROM THOSE SEEN HERE). 3412 Apex Peakway Apex, North Carolina 27502 P 919 460-5200 F 919 460 5250www.firetrol.com While every precaution has been taken to ensure accuracy and completeness herein, Firetrol, Inc. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications and drawings are subject to change without notice. ©2022 Firetrol, Inc., All Rights Reserved. Project Information Firetrol Limited Option Jockey Pump Controller FTA560F - Full Voltage Starting Specifications 1.0 Main Fire Pump ControllerThe auxiliary jockey pump controller, if required and specified on the plans and spec- ifications, shall be factory assembled, wired, and tested and specifically designed for this type of service. This controller shall be of the same manufacturer as the main fire pump controller. 1.1 Standards, Listings & Approvals The controller shall conform to all the requirements of the latest editions of: NFPA 70, National Electrical Code. The controller shall be listed by:Underwriters Laboratories, Inc., in accordance with UL508A, Standard for Industrial ControlsCanadian Standards Association CSA-C22.2, Standard for Industrial Control Equipment (cUL) 1.2 Enclosure The controller components shall be housed in a NEMA Type 2/12 (IEC IP22/IP54) poly-carbonate, wall mounted enclosure (UL50E Construction). 1.3 Withstand Ratings (Short Circuit Current Ratings) The jockey shall have standard short circuit current ratings of: 30kA @ 480 Volts Max. (3-Phase) 18kA @ 600 Volts (3-Phase)5kA @ 240 Volts Max. (1-Phase) 1.4 Construction The jockey pump controller shall be full voltage starting, rated for wye-connected power systems above 240V. The controller shall incorporate a horsepower rated manual cir- cuit protector and starting contactor, control circuit transformer with 24VAC secondary and 200-600V multi-tap primary, main disconnect switch, and a 0-600 psi (0-42 bar) solid state pressure transducer. 1.5 Operator Interface The jockey pump controller shall feature an operator interface with user keypad. The interface shall feature a 4 digit digital display. LED indication of pressure above stop setting (Green), pressure between stop and start settings (Yellow), and pressure below the start setting (Red). LED indication of motor run (manual start and automatic start). Start/Stop and Off/Automatic push-buttons. User settings such as start/stop pressure settings, timer settings and units of measure shall be programmable from the user interface without opening the enclosure door. 1.6 Solid State Pressure Transducer The controller shall be supplied with a solid state pressure transducer with a range of 0-600 psi (0-42 bar) ±1 psi. The solid state pressure switch shall be used for both display of the system pressure and control of the fire pump controller. Systems using analog pressure devices or mercury switches for operational control will not be accepted. The START, STOP and SYSTEM PRESSURE shall be digitally displayed and adjustable through the user interface. The pressure transducer shall be mounted inside the controller to prevent accidental damage. The pressure transducer shall be directly pipe mounted to a bulkhead pipe coupling without any other supporting members. Field connections shall be made externally at the controller coupling to prevent distortion of the pressure switch element and mechanism. 1.7 Controller Operation A digitally set On Delay (Sequential Start) timer shall be provided as standard. The controller shall include a Minimum Run Timer to allow the motor to run for a set period of timer after starting. The timer shall be programmable through the user interface. The disconnect switch shall be mechanically interlocked so that the enclosure door cannot be opened with the handle in the ON position except by a hidden tool operated defeater mechanism. The disconnect switch shall be capable of being padlocked in the OFF position for installation and maintenance safety. 1.8 Manufacturer The controller shall be a Firetrol brand. Publication SP560F-01 Rev. A 3412 Apex Peakway Apex, North Carolina 27502 P +1 919 460 5200 F +1 919 460 5250 www.firetrol.com While every precaution has been taken to ensure accuracy and completeness herein, Firetrol, Inc. assumes no responsibility, and disclaims all liability, for damages result- ing from use of this information or for any errors or omissions. Specifications and drawings are subject to change without notice. ©2021 Firetrol, Inc., All Rights Reserved. Description—Firetrol® FTA560F Jockey Pump Con- trollers are intended for use with fire pump sys- tems. They are used for pressure maintenance in fire pump installations to prevent unnecessary operation of the main fire pump. Approvals—Firetrol jockey pump controllers are listed by Underwriters’ Laboratories, Inc., in ac- cordance with UL508A, Standard for Industrial Controls, and CSA, Standard for Industrial Control Equipment. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest edition NFPA 70, National Electrical Code. Standard Features—The following are included as standard with each controller: • NEMA Type 2/12 (IEC IP22/IP54) Polycarbonate enclosure (UL50E Construction) • Horsepower rated motor circuit protector and starting contactor • Suitable for use as service equipment • OFF-AUTO push-buttons • Minimum run timer • On-Delay timer • Control circuit transformer with 24VAC secondary • 0-600 psi (0-42 bar) solid state pressure transducer • Visual Indication, Controller in AUTO • Door mounted pressure display/user inter- face. • LED indication for pressure above stop setting (green), pressure between start and stop set- ting (yellow), and pressure below start setting (red). • Start and Stop push-buttons • Rotary style door mounted disconnect handle with door interlock NOTE: FTA560F Jockey Pump Controllers are only available in the voltage/horsepower combinations shown below and with the options shown on the reverse side. For other combinations and options, see docu- mentation for FTA560E series Jockey Pump Controllers. VOLTAGE 3-PHASE MAX HP Short Circuit(50/60 Hertz) (MCP) Current Rating -H 200-208 7.5 30kA -A 220-240 10 30kA -F 380-415V-WYE 15 30kA -B 440-480V-WYE 20 30kA -C 550-600V-WYE 20 18kA VOLTAGE 1-PHASE MAX HP Short Circuit(50/60 Hertz) (MCP) Current Rating -D 110-120 Volts 2 5kA -T 200-208 Volts 3 5kA -E 220-240 Volts 5 5kA NOTE: Firetrol Brand Jockey Pump controllers DO NOT CONTAIN MERCURY filled pressure switches. Limited Option Jockey Pump Controllers Product Description FTA560F Publication PD560F-01 3412 Apex Peakway Apex, North Carolina 27502 P +1 919 460 5200 F +1 919 460 5250 www.firetrol.com While every precaution has been taken to ensure accuracy and completeness herein, Firetrol, Inc. assumes no responsibility, and disclaims all liability, for damages result- ing from use of this information or for any errors or omissions. Specifications and drawings are subject to change without notice. ©2021 Firetrol, Inc., All Rights Reserved. For Model # Information and Options & Modifications see Publication SD560F-01 FTA560F JOCKEY PUMP CONTROLLERS FTA NUMBER FTA560F TIMER OPTION -A With Programmable Running Period Timer MOTOR CURRENT PROTECTION -G Manual Motor Protector *Suitable for Use as Service Equipment* Short Circuit Current Rating 3 Phase --200-480V - 30kA /600V - 18kA 1 Phase -- 110-240V - 5kA HORSEPOWER (KW) 014 - 1/4 HP (.18) 004 - 4 HP (3) 013 - 1/3 HP (.23) 005 - 5 HP (3.7) 012 - 1/2 HP (.37) 006 - 5 1/2 HP (4) 034 - 3/4 HP (.56) 007 - 7 1/2 HP (5.5) 001 - 1 HP (.75) 010 - 10 HP (7.5) 011 - 1 1/2 HP (1.1) 015 - 15 HP (11) 002 - 2 HP (1.5) 020 - 20 HP (15) 003 - 3 HP (2.2) (See Voltage Selection for Maximum HP/Voltage Combinations) FTA560F-A G - (Example: FTA560F-AG015B-T-BY) OPTIONS & MODIFICATIONS (See other side) VOLTAGE 3-PHASE MAX HP (50/60 Hertz) -H 200-208 Volts 7.5 -A 220-240 Volts 10 -F 380-415V - WYE 15 -B 440-480V - WYE 20 -C 550-600V - WYE 20 VOLTAGE 1-PHASE MAX HP (50/60 Hertz) -D 110-120 Volts 2 -T 200-208 Volts 3 -E 220-240 Volts 3 NOTE: For requirements not listed here (higher short circuit ratings, larger horsepowers, options not listed... etc) please refer to documentation for FTA560E series Jockey Pump Controllers. Limited Option Jockey Pump Controllers Model Number Selection Guide FTA560F Model Number Selection Guide - Options & Modifications Publication SD560F-01 Rev. A 3412 Apex Peakway Apex, North Carolina 27502 P +1 919 460 5200 F +1 919 460 5250 www.firetrol.com While every precaution has been taken to ensure accuracy and completeness herein, Firetrol, Inc. assumes no responsibility, and disclaims all liability, for damages result- ing from use of this information or for any errors or omissions. Specifications and drawings are subject to change without notice. ©2021 Firetrol, Inc., All Rights Reserved. *Export Packaging available for additional cost NOTE: For requirements not listed here (higher short circuit ratings, larger horsepowers, options not listed...etc) please refer to documentation for FTA560E series Jockey Pump Controllers. SPECIAL ENCLOSURES DescriptionOption -E Enclosure, NEMA Type 4 (IEC IP65), Non-Metallic Enclosure -F Enclosure, NEMA Type 4X (IEC IP66), Non-Metallic Enclosure -T Enclosure, NEMA Type 3R (IEC IP24), Non-Metallic Enclosure --- Enclosure, NEMA Type 2/12 (IEC IP22/IP54) Polycarbonate enclosure (UL50E Construction) ANTI-CONDENSATION SPACE HEATERS (power source by others) DescriptionOption -J Space Heater, 120V Externally Powered with Circuit Breaker & Thermostat -K Space Heater, 120V Externally Powered with Circuit Breaker & Humidistat -M Space Heater, 240V Externally Powered with Circuit Breaker & Thermostat -N Space Heater, 240V Externally Powered with Circuit Breaker & Humidistat None PRESSURE TRANSDUCERS DescriptionOption --- Wetted Parts Including Pressure Sensor, 600 PSI (42 bar), Fresh Water -D Wetted Parts Including Pressure Sensor, 600 PSI (42 bar), Sea Water ALARMS DescriptionOption -AC Alarm Output Contacts, Pump Operating (2 Sets) -AM Alarm Output Contacts, Fail To Start -BW1 Alarm Output Contacts/Visible Indication, Phase Failure/Phase Reversal -BY Alarm Output Contacts, Pump Overload -EF1 Alarm Output Contacts, Controller Not In Auto (1 set) -HV Alarm, Audible -KH Alarm Output Contacts, Common Alarm MISCELLANEOUS DescriptionOption -NZ Input Terminals, Shutdown Interlock -S Tropicalization -AST Input Terminals, Automatic Start Dimensions andShipping Weight Limited Option Jockey Pump Controllers FTA560F Wiring Schematic Limited Option Jockey Pump Controllers with MMP FTA560F