Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
VICTAULIC CHECK VALVE - 23-00006 - Hibbard Elemenatry - Fire Sprinkler
victaulic.com 08.10 1537 Rev H Updated 07/2019 © 2019 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Ports Ports 1.0 PRODUCT DESCRIPTION Available Sizes • 4 – 12”/DN100 – DN300 • Grooved end connections Maximum Working Pressure • 300 psi/2068 kPa/21 bar Operating Temperature Range • –30°F to +300°F/–34°C to +149°C Function • Check valve with hydrodynamic inlet profile that provides a natural venturi • Drilled, tapped and plugged inlet, ready to receive the flow measuring kit Application • Can be installed horizontally or vertically • Allows direct connection to Victaulic Vic-300 MasterSeal™ butterfly valves or Series 377 Vic-Plug valves 2.0 CERTIFICATION/LISTINGS Not applicable. Contact Victaulic with any questions. Victaulic® Venturi Check Valve and Flow Measuring Kit Series 779 08.10 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 08.10 1537 Rev H Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com Valve Body: Ductile iron conforming to ASTM A536, Grade 65-45-12, painted black enamel. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Disc Coating: (specify choice1) Victaulic EPDM EPDM (Green color code). Temperature range –3O°F to +23O°F/–34°C to +llO°C. NOT RECOMMENDED FOR PETROLEUM SERVICES OR STEAM SERVICES. Victaulic Nitrile Nitrile (Orange color code). Temperature range +10°F to +15O°F/–l2°C to +65°C. Not compatible for hot water services over +15O°F/+66°C or for hot dry air over +l40°F/6O°C. NOT RECOMMENDED FOR HOT WATER SERVICES OR STEAM SERVICES. Victaulic Fluoroelastomer Fluoroelastomer (Blue color code). Temperature range +2O°F to +3OO°F/–7°C to +l49°C. NOT RECOMMENDED FOR HOT WATER SERVICES OR STEAM SERVICES 1 Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: Ductile iron conforming to ASTM A536, Grade 65-45-12, fully encapsulated in Grade “E”, “T”, or “O” elastomer. (Reference Disc Coating listed above.) Shaft: Type 316 stainless steel. Spring: Type 302/304 stainless steel. Shaft Plug: Carbon steel zinc plated to ASTM B633. Flow Measuring Kit (Hardware is same for all sizes): • Extension nipples • Bronze access valves • Quick disconnect for meter connection (per ISO 7241-1 Series B) 3.0 SPECIFICATIONS – MATERIAL 2 victaulic.com 08.10 1537 Rev H Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS E B D K P G F C A 45° Port “L” E B D K P G F C A 45° Port “L”KB A P ED C G F Typical 4"/DN100 Typical 5 – 6"/139.7 mm – DN150 Typical 8 – 12"/DN200 – DN300 Size Dimensions Weight Nominal inches DN Actual Outside Diameter inches mm E-E A inches mm B inches mm C inches mm D inches mm E inches mm F inches mm G inches mm K inches mm P inches mm Approximate Each lb kg 4†4.500 9.63 5.88 3.88 2.75 3.50 1.50 2.38 4.50 3.50 16.0 DN100 114.3 245 149 99 70 89 38 60 114 89 7.3 5†5.563 141.3 10.50 267 6.75 171 4.50 114 4.25 108 4.25 108 1.65 42 2.38 60 5.88 149 4.08 104 20.0 9.1 5.500 10.50 6.75 4.50 4.25 4.25 1.65 2.38 5.88 4.08 20.0 DN125†139.7 267 171 114 108 108 42 60 149 104 9.1 6† DN150 6.625 168.3 11.50 292 8.00 203 5.00 127 4.50 114 4.50 114 1.58 40 2.68 68 6.68 170 4.75 121 28.0 12.7 6.500*11.50 8.00 5.00 4.50 4.50 1.58 2.68 6.68 4.75 28.0 165.1 292 203 127 114 114 40 68 170 121 12.7 8* DN200 8.625 219.1 14.00 356 9.88 251 6.06 154 5.06 129 5.68 144 1.75 44 3.25 83 8.88 226 5.75 146 40.0 18.1 10*10.750 17.00 12.00 7.12 6.00 6.68 1.82 3.94 10.94 6.94 100.0 DN250 273.0 432 305 181 152 170 46 100 278 176 45.4 12* DN300 12.750 323.9 19.50 495 14.00 356 8.06 205 6.91 176 7.68 195 1.82 46 3.32 84 12.82 326 7.93 201 140.0 63.5 NOTES † Port “L” located 45° off centerline of valve body. * Both ports on centerline of valve body 3 victaulic.com 08.10 1537 Rev H Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE CV/KV values for flow of water at +60°F/+16°C are shown in the table below. Formulas for CV and KV values ΔP = Q2/C 2 2V ΔP = Q /K 2V Q = CV × √ΔP Q = KV × √ΔP Where: Q = Flow (GPM) ΔP = Pressure Drop (psi) CV = Flow Coefficient K V = Flow Coefficient Size CV/KV Actual Outside Nominal Diameter inches inches (Full DN mm Open) 4 4.500 390 DN100 114.3 337 5 5.563 700 141.3 606 DN125 5.500 707 139.7 606 6 6.625 1000 DN150 168.3 865 6.500 1000 165.1 865 8 8.625 1800 DN200 219.1 1557 10 10.750 3000 DN250 273.0 2595 12 12.750 4200 DN300 323.9 3633 NOTE • Placement of check valves too close to sources of unstable flow will shorten the life of the valve and potentially may damage the system. To extend valve life, valves should be installed a reasonable distance downstream from pumps, elbows, expanders, reducers or other similar devices. Sound piping practices dictate a minimum of five (5) times the pipe diameter for general use. Distances between three (3) and five (5) diameters are allowable provided the flow velocity is less than eight (8) feet per second. Distances less than three (3) diameters are not recommended and will violate the Victaulic product warranty 4 victaulic.com 08.10 1537 Rev H Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE (CONTINUED) Flow Characteristics 800 3,000 8,000 6.05.0 4.0 3.0 2.0 1.00.90.80.7 0.6 0.5 0.4 0.3 0.2 0.1 10 20 30 40 50 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,0005" 4"8"6"10"12"Flow Rate - GPMPressure Drop - psi1.00 10.00 100.00 100 1000 10000 1000004"5"6"8"10"12" FLOW (L/min)PRESSURE LOSS– (kpa)5 victaulic.com 08.10 1537 Rev H Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE (CONTINUED) Tables for calculating flow rates based on venturi differential pressure measurements 4 "/10 0 m m ΔP ΔP Velocity*Flow ΔP ΔP Velocity*Flow PSI kPa In. H20 kPa Ft./Sec m/s GPM L/min. PSI kPa In. H20 kPa Ft./Sec m/s GPM L/min. 0.16 4.4 3 119 1.65 45.8 10 397 1.1 1.1 0.91 450 11.4 11.4 3.0 1502.8 0.28 7.7 4 159 2.38 66.0 12 476 1.9 1.9 1.22 602 16.4 16.4 3.7 1801.9 0.61 16.9 6 238 3.28 90.9 14 556 4.2 4.2 1.83 901 22.6 22.6 4.3 2104.7 1.11 30.8 8 320 4.28 118.7 16 635 7.6 7.6 2.44 1211 29.6 29.5 4.9 2403.7 5"/125 mm ΔP ΔP Velocity*Flow ΔP ΔP Velocity*Flow PSI In. H20 Ft./Sec GPM PSI In. H20 Ft./Sec GPM kPa kPa m/s L/min.kPa kPa m/s L/min. 0.20 5.5 3 186 2.23 61.8 10 624 1.4 1.4 0.91 704 15.4 15.4 3.05 2362 0.35 9.7 4 249 3.13 86.8 12 744 2.4 2.4 1.22 942 21.6 21.6 3.66 2816 0.76 21.0 6 372 4.25 117.8 14 868 5.2 5.2 1.83 1408 29.3 29.3 4.27 3285 1.40 38.8 8 499 9.7 9.7 2.4 1889 6"/150 mm ΔP ΔP Velocity*Flow ΔP ΔP Velocity*Flow PSI kPa In. H20 kPa Ft./Sec m/s GPM L/min. PSI kPa In. H20 kPa Ft./Sec m/s GPM L/min. 0.12 3.3 3 270 1.39 38.5 10 901 0.8 0.8 0.91 1022 9.6 9.6 3.05 3410 0.27 7.5 4 360 2.0 55.5 12 1081 1.9 1.9 1.22 1363 13.8 13.8 3.66 4092 0.51 14.1 6 540 2.78 77.1 14 1261 3.5 3.5 1.83 2044 19.2 19.2 4.27 4773 0.88 24.4 8 720 3.6 99.8 16 1441 6.1 6.1 2.44 2725 24.8 24.8 4.88 5454 8"/200 mm ΔP ΔP Velocity*Flow ΔP ΔP Velocity*Flow PSI In. H20 Ft./Sec GPM PSI In. H20 Ft./Sec GPM kPa kPa m/s L/min.kPa kPa m/s L/min. 0.10 2.7 3 471 1.05 29.1 10 1559 0.7 0.7 0.91 1783 7.2 7.2 3.05 5901 0.17 4.7 4 623 1.55 43.0 12 1871 1.2 1.2 1.22 2358 10.7 10.7 3.66 7082 0.38 10.5 6 936 2.08 57.7 14 2182 2.6 2.6 1.83 3543 14.3 14.3 4.27 8259 0.68 18.8 8 1247 3.45 95.6 18 2800 4.7 4.7 2.44 47 23.8 23.8 5.49 10598 10 "/2 5 0 m m ΔP ΔP Velocity*Flow ΔP ΔP Velocity*Flow PSI kPa In. H20 kPa Ft./Sec m/s GPM L/min. PSI kPa In. H20 kPa Ft./Sec m/s GPM L/min. 0.13 3.6 3 741 1.36 37.7 10 2457 0.9 0.9 0.91 2805 9.4 9.4 3.05 9300 0.23 6.4 4 983 1.96 54.4 12 2948 1.6 1.6 1.22 3721 13.5 13.5 3.66 11158 0.49 13.6 6 1474 2.70 74.8 14 3440 3.4 3.4 1.83 5579 18.6 18.6 4.27 13020 0.88 24.4 8 1966 3.50 97.1 16 4000 6.1 6.1 2.44 7441 24.1 24.1 4.88 15140 12"/300 mm ΔP ΔP Velocity*Flow ΔP ΔP Velocity*Flow PSI In. H20 Ft./Sec GPM PSI In. H20 Ft./Sec GPM kPa kPa m/s L/min.kPa kPa m/s L/min. 0.08 2.2 2 697 1.12 30.9 8 3438 0.6 0.6 0.61 2638 2.7 7.7 2.44 13013 0.18 5.0 3 1046 1.80 50.0 10 4298 1.2 1.2 0.91 3959 12.4 12.4 3.05 16266 0.33 9.1 4 1396 2.67 74.1 12 5157 2.3 2.3 1.22 5284 18.4 18.4 3.66 19519 0.71 19.7 6 2092 4.9 4.9 1.83 7918 6 victaulic.com 08.10 1537 Rev H Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. Victaulic Victaulic products for a particular end-use application, in accordance with industry recommends all products to be installed in accordance with current IMI TA installation/ standards and project specifications, and the applicable building codes and related assembly instructions. Victaulic and IMI TA reserve the right to change product regulations as well as Victaulic performance, maintenance, safety, and warning specifications, designs and standard equipment without notice and without incurring instructions. Nothing in this or any other document, nor any verbal recommendation, obligations. advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Installationor waive any provision of Victaulic Company's standard conditions of sale, installation Reference should always be made to the current IMI TA installation/assembly instructions guide, or this disclaimer.for the product you are installing. For coupling and strainer installation, reference should Intellectual Property Rights always be made to the I-100 Victaulic Field Installation Handbook for the product you are No statement contained herein concerning a possible or suggested use of any material, installing. Handbooks are included with each shipment of Victaulic products for complete product, service, or design is intended, or should be constructed, to grant any license installation and assembly data, and are available in PDF format on our website at www. under any patent or other intellectual property right of Victaulic or any of its subsidiaries victaulic.com or affiliates covering such use or design, or as a recommendation for the use of such Warrantymaterial, product, service, or design in the infringement of any patent or other intellectual Refer to the Warranty section of the current Price List or contact Victaulic for details.property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other Trademarks countries.Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 6.0 NOTIFICATIONS WARNING • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic pip- ing products. • Always verify that the piping system has been completely depressurized and drained immediately prior to instal- lation, removal, adjustment, or maintenance of any Victaulic products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCES I-100: Victaulic Field Installation Handbook 7 victaulic.com