Loading...
HomeMy WebLinkAboutFSONEINSTALLATION - 23-00006 - Hibbard Elemenatry - Fire Sprinkler5 1-800-879-8000 R Installation InstructionsFS-ONEHigh PerformanceIntumescent Firestop SealantProduct description• Intumescent (expands when exposed to fire) firestop sealant thathelps protect combustible and non-combustible penetrations for up to 4 hours fire ratingProduct features• Smoke, gas and water resistant• Contains no halogen, solvents or asbestos• High fire rating properties• Water based, easy to cleanTested in accordance with• UL 1479• ASTM E 814• UL 2079 Technical DataFS-ONE Intumescent Firestop(at 73°F (23°C) and 50% relative humidity)Chemical basis: Water-based intumescent acrylic dispersionDensity: Approx. 1.5 g/cm3Color: RedWorking time: Approx. 20-30 minCuring time: Approx. 14-21 daysShore A Hardness: Approx. 35Movement capability: Approx. 5%Intumescent Activation: Approx 250°F (121°C)Expansion rate (unrestricted): Up to 3-5 times original volumeTemperature resistance (cured): -40°F (-40°C) to 212°F (100°C)Application temperature: 35°F (2°C) to 100°F (38°C) Surface burning characteristics: Flame Spread: 0(ASTM E 84-96) Smoke Development: 5ApprovalsICBO Evaluation Service, Inc. Report No. 5071California State Fire Marshal Listing No. 1200:108City of New York MEA 326-96-MCity of Los Angeles Research Report 25188 Opening 1. Clean the opening. Surfaces to which FS-ONE will be applied should be cleaned of loose debris, dirt, oil, moisture, frost and wax. Structures supporting penetrating items must be installed in compliance with local building and electrical standards Application of firestop sealant 2. Install the prescribed backfilling material type and depth to obtain the desired rating (if required). Leave sufficient depth for applying FS-ONE. 3. Application of firestop sealant: Apply FS-ONE to the required depth in order to obtain the desired fire rating. Make sure FS-ONE contacts all surfaces to provide maximum adhesion. For application of FS-ONE use a standard caulking gun, foil pack gun, bulk loader and bulk gun. With FS-ONE buckets, Graco type sealant pumps may be used. (Contact pump manufacturer for proper selection.) 4. Smoothing of firestop sealant: To complete the seal, tool immedi- ately to give a smooth appearance. Excess sealant, prior to curing, can be cleaned away from adjacent surfaces and tools with water. 5. Leave completed seal undisturbed for 48 hours. 6. For maintenance reasons, a penetration seal could be permanently marked with an identification plate. In such a case, mark the iden- tification plate and fasten it in a visible position next to the seal. Notice about approvals Check that the penetration has been sealed according to the specified drawing in the UL Fire Resistance Directory or Hilti Firestop manual. For further advice, please contact Hilti customer service. Refer to Hilti product literature and UL fire resistance directory for specific application details. Not to be used... • For high movement expansion joints • Underwater • On building materials which bleed oil, plasticizers or solvents (impregnated wood, oil-based seals, green or partially vulcanized rubber) • In any penetration other than those specifically described in the Hilti Firestop Manual or the test reports Safety precautions • Before handling, read the product and material safety data sheet for detailed use and health information. • Keep out of reach of children • Wear suitable gloves and eye protection Storage • Store only in the original packaging in a location protected from moisture at temperatures between 40°F (5°C) and 86°F (30°C). • Observe expiration date on the packaging. 1. Clean opening. 2. Pack mineral wool. (If required) 3. Apply FS-ONE. 4. Smooth FS-ONE. 5. Leave completed seal undisturbed for 48 hours. 6. Fasten identification plate (if required). Installation instructions for FS-ONE Firestop System