Loading...
HomeMy WebLinkAboutANVIL SEISMIC CLAMP - 23-00006 - Hibbard Elemenatry - Fire SprinklerPROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: SEISMIC BRACES PH-07.20 Fig. AF730 Longitudinal & Lateral Seismic Clamp Size Range: Service Pipe Size: 1" through 12", DN25 through DN100 Material: Carbon Steel Clamp and Hardware. Ductile Iron Brace Member Attachment Fitting. Finish: q Plain or q Electro-Galvanized per ASTM B633 Service: A seismic clamp designed to connect a piping system to a brace member. The AF730 rigidly braces piping systems subjected to horizontal longitudinal and lateral seismic loads. The AF730 may also be installed to rigidly brace piping systems subjected to vertical seismic loads. Approvals: cULus Listed (ANSI/UL 203a) and FM Approved (FM 1950-13). FM Tested (ANSI/FM 1950-16). Complies with NFPA 13, ASCE 7, IBC, & MSS SP-127 bracing requirements. Features: • Torque off set screw and nuts provide a visual indication that the desired installation torque values have been achieved. • Eliminates brace member eccentricity by concentrically loading 1" and DN25 brace pipes. Ordering: Specify figure number, service pipe size, finish, and description. Notes: Anvil International® brand bracing components are designed to be compatible ONLY with other Anvil International® brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.ul.com and updated FM approval information may be viewed at www.approvalguide.com. Disclaimer: Anvil International (“Anvil”) does not provide any warranties and specifically disclaims any liability whatsoever with respect to Anvil bracing products and components that are used in combination with products, parts or systems not manufactured or sold by Anvil. In no event shall Anvil be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-Anvil bracing components have been, or are used. SeisBrace® Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com FIG. AF730: DIMENSIONS AND WEIGHT Size A B Y Weight 1" (DN25) 7.6 in (193 mm) 1.50 in (38.1 mm) 1.91 in (48.5 mm) 2.49 lbs (1.13 kg) 11/4" (DN32) 8.0 in (203 mm) 2.55 lbs (1.16 kg) 11/2" (DN40) 8.2 in (208 mm) 2.64 lbs (1.20 kg) 2" (DN50) 8.7 in (221 mm) 2.78 lbs (1.26 kg) 21/2"9.2 in (234 mm) 2.92 lbs (1.32 kg) 3" (DN80) 9.8 in (249 mm) 3.13 lbs (1.42 kg) 4" (DN100) 10.8 in (274 mm) 3.38 lbs (1.53 kg) 5"12.1 in (307 mm) 3.81 lbs (1.73 kg) 6"13.2 in (335 mm) 4.12 lbs (1.87 kg) 8"15.2 in (386 mm) 4.72 lbs (2.14 kg) 10"18.1 in (460 mm) 7.60 lbs (3.45 kg) 12"20.1 in (511 mm) 8.60 lbs (3.90 kg) B Y A SEISMIC BRACES PH-07.20 Fig. AF730 Longitudinal & Lateral Seismic Clamp (cont.) FIG. AF730 cULus Listing per ANSI/UL 203A (ASD) Service Pipe Size Standard Service Pipe Specialty Service Pipe Horizontal Load Rating at Brace Angle Longitudinal Load Rating Lateral Load Rating 30˚-44˚45˚-59˚60˚-90˚Listed 30˚-44˚45˚-59˚60˚-90˚Listed 1" (DN25) Sch. 10 Sch. 40 Metric Pipe Mega-Thread MLT / GL Eddy Thread EZ-Thread 340 lbf (1.51 Kn) 480 lbf (2.14 Kn) 588 lbf (2.62 Kn) 680 lbf (3.02 Kn) 340 lbf (1.51 Kn) 480 lbf (2.14 Kn) 588 lbf (2.62 Kn) 680 lbf (3.02 Kn) 11/4" (DN32) Sch. 10 Sch. 40 Metric Pipe Mega-Flow MLT / GL Mega-Thread Eddy Flow Eddy Thread EZ-Thread 375 lbf (1.67 Kn) 530 lbf (2.36 Kn) 649 lbf (2.89 Kn) 750 lbf (3.34 Kn) 375 lbf (1.67 Kn) 530 lbf (2.36 Kn) 649 lbf (2.89 Kn) 750 lbf (3.34 Kn) 11/2" (DN40) Sch. 10 Sch. 40 Metric Pipe Mega-Flow MLT / GL Mega-Thread Eddy Flow Eddy Thread Fire-Flo EZ-Thread 375 lbf (1.67 Kn) 530 lbf (2.36 Kn) 649 lbf (2.89 Kn) 750 lbf (3.34 Kn) 375 lbf (1.67 Kn) 530 lbf (2.36 Kn) 649 lbf (2.89 Kn) 750 lbf (3.34 Kn) 2" (DN50) Sch. 10 Sch. 40 Metric Pipe Mega-Flow MLT / GL Mega-Thread Eddy Flow Eddy Thread Fire-Flo EZ-Thread 375 lbf (1.67 Kn) 530 lbf (2.36 Kn) 649 lbf (2.89 Kn) 750 lbf (3.34 Kn) 375 lbf (1.67 Kn) 530 lbf (2.36 Kn) 649 lbf (2.89 Kn) 750 lbf (3.34 Kn) 21/2"Sch. 10 Sch. 40 Mega-Flow Eddy Flow Fire-Flo 545 lbf (2.42 Kn) 770 lbf (3.43 Kn) 943 lbf (4.19 Kn) 1090 lbf (4.85 Kn) 545 lbf (2.42 Kn) 770 lbf (3.43 Kn) 943 lbf (4.19 Kn) 1090 lbf (4.85 Kn) 3" (DN80) Sch. 10 Sch. 40 Metric Pipe Mega-Flow Eddy Flow Fire-Flo 545 lbf (2.42 Kn) 770 lbf (3.43 Kn) 943 lbf (4.19 Kn) 1090 lbf (4.85 Kn) 545 lbf (2.42 Kn) 770 lbf (3.43 Kn) 943 lbf (4.19 Kn) 1090 lbf (4.85 Kn) 4" (DN100) Sch. 10 Sch. 40 Metric Pipe Mega-Flow Eddy Flow Fire-Flo 545 lbf (2.42 Kn) 770 lbf (3.43 Kn) 943 lbf (4.19 Kn) 1090 lbf (4.85 Kn) 545 lbf (2.42 Kn) 770 lbf (3.43 Kn) 943 lbf (4.19 Kn) 1090 lbf (4.85 Kn) 5"Sch. 10 Sch. 40 – 545 lbf (2.42 Kn) 770 lbf (3.43 Kn) 943 lbf (4.19 Kn) 1090 lbf (4.85 Kn) 545 lbf (2.42 Kn) 770 lbf (3.43 Kn) 943 lbf (4.19 Kn) 1090 lbf (4.85 Kn) 6"Sch. 10 Sch. 40 Mega-Flow 685 lbf (3.05 Kn) 968 lbf (4.31 Kn) 1186 lbf (5.28 Kn) 1370 lbf (6.09 Kn) 685 lbf (3.05 Kn) 968 lbf (4.31 Kn) 1186 lbf (5.28 Kn) 1370 lbf (6.09 Kn) 8"0.188" Wall Sch. 40 –685 lbf (3.05 Kn) 968 lbf (4.31 Kn) 1186 lbf (5.28 Kn) 1370 lbf (6.09 Kn) 685 lbf (3.05 Kn) 968 lbf (4.31 Kn) 1186 lbf (5.28 Kn) 1370 lbf (6.09 Kn) 10"0.188" Wall Sch. 40 –942 lbf (4.19 Kn) 1333 lbf (5.93 Kn) 1632 lbf (7.26 Kn) 1885 lbf (8.38 Kn) 942 lbf (4.19 Kn) 1333 lbf (5.93 Kn) 1632 lbf (7.26 Kn) 1885 lbf (8.38 Kn) Brace Pipe Angles are determined from Vertical. Sch. 10 & 0.188" Wall Load Ratings may be used for any thicker wall pipe of the same diameter. Listed load ratings reduced for angle ranges in accordance with NFPA 13-2019 Table 18.5.2.3. See table on page 4 for UL listed specialty pipes & UL Listed metric service pipes. See table on page 4 for UL listed brace members. Load ratings include a minimum safety factor of 2.2 in accordance with NFPA 13-2019 Section A.18.5.2.3. All load ratings may be used for NFPA 13-2016 designs. Longitudinal Application Lateral Application Riser Application SEISMIC BRACES PH-07.20 Fig. AF730 Longitudinal & Lateral Seismic Clamp (cont.) FIG. AF730 FM Approved (Listing) per FM 1950-13 (ASD) Service Pipe Size Standard Service Pipe Specialty Service Pipe Horizontal Load Rating at Brace Angle Longitudinal Load Rating Lateral Load Rating 30˚-44˚45˚-59˚60˚-74˚75˚-90˚30˚-44˚45˚-59˚60˚-74˚75˚-90˚ 1" (DN25) Sch. 10 Sch. 40 Metric Pipe Mega-Thread MLT / GL Eddy Thread EZ-Thread 550 lbf (2.45 Kn) 640 lbf (2.85 Kn) 670 lbf (2.98Kn) 740 lbf (3.29 Kn) 1740 lbf (7.74 Kn) 2460 lbf (10.94 Kn) 3010 lbf (13.39 Kn) 3360 lbf (14.95 Kn) 11/4" (DN32) Sch. 10 Sch. 40 Metric Pipe Mega-Flow MLT / GL Mega-Thread Eddy Flow Eddy Thread EZ-Thread 740 lbf (3.29 Kn) 680 lbf (3.02 Kn) 820 lbf (3.65 Kn) 1620 lbf (7.21 Kn) 1430 lbf (6.36 Kn) 2020 lbf (8.99 Kn) 2480 lbf (11.03 Kn) 2770 lbf (12.32 Kn) 11/2" (DN40) Sch. 10 Sch. 40 Metric Pipe Mega-Flow MLT / GL Mega-Thread Eddy Flow Eddy Thread Fire-Flo EZ-Thread 800 lbf (3.56 Kn) 650 lbf (2.89 Kn) 790 lbf (3.51 Kn) 1800 lbf (8.01 Kn) 1790 lbf (7.96 Kn) 2530 lbf (11.25 Kn) 3100 lbf (13.79 Kn) 3460 lbf (15.39Kn) 2" (DN50) Sch. 10 Sch. 40 Metric Pipe Mega-Flow MLT / GL Mega-Thread Eddy Flow Eddy Thread Fire-Flo EZ-Thread 830 lbf (3.69 Kn) 990 lbf (4.4 Kn) 1190 lbf (5.29 Kn) 1620 lbf (7.21 Kn) 1820 lbf (8.1 Kn) 2580 lbf (11.48 Kn) 3160 lbf (14.06 Kn) 3530 lbf (15.7 Kn) 21/2"Sch. 10 Sch. 40 Mega-Flow Eddy Flow Fire-Flo 800 lbf (3.56 Kn) 700 lbf (3.11 Kn) 850 lbf (3.78 Kn) 1930 lbf (8.59 Kn) 1610 lbf (7.16 Kn) 2280 lbf (10.14 Kn) 2790 lbf (12.41Kn) 3120 lbf (13.88 Kn) 3" (DN80) Sch. 10 Sch. 40 Metric Pipe Mega-Flow Eddy Flow Fire-Flo 960 lbf (4.27 Kn) 1330 lbf (5.92 Kn) 1540 lbf (6.85 Kn) 1700 lbf (7.56 Kn) 1550 lbf (6.89 Kn) 2200 lbf (9.79 Kn) 2690 lbf (11.97 Kn) 3010 lbf (13.39 Kn) 4" (DN100) Sch. 10 Sch.40 Metric Pipe Mega-Flow Eddy Flow Fire-Flo 760 lbf (3.38 Kn) 1040 lbf (4.63 Kn) 1270 lbf (5.65 Kn) 1400 lbf (6.23 Kn) 1260 lbf (5.6 Kn) 1790 lbf (7.96 Kn) 2190 lbf (9.74 Kn) 2440 lbf (10.85 Kn) 5"Sch. 10 Sch. 40 –890 lbf (3.96 Kn) 1230 lbf (5.47 Kn) 1410 lbf (6.27 Kn) 1550 lbf (6.89 Kn) 1260 lbf (5.6 Kn) 1790 lbf (7.96 Kn) 2190 lbf (9.74 Kn) 2440 lbf (10.85 Kn) 6" Sch. 10 Sch.40 Metric Pipe Mega-Flow 700 lbf (3.11 Kn) 940 lbf (4.18 Kn) 1140 lbf (5.07 Kn) 1310 lbf (5.83 Kn) 950 lbf (4.23 Kn) 1340 lbf (5.96 Kn) 1640 lbf (7.3 Kn) 1830 lbf (8.14 Kn) 8"0.188" Wall Sch. 40 –990 lbf (4.4 Kn) 1130 lbf (5.03 Kn) 1360 lbf (6.05 Kn) 1520 lbf (6.76 Kn) 1540 lbf (6.85 Kn) 2170 lbf (9.65 Kn) 2660 lbf (11.83 Kn) 2970 lbf (13.21 Kn) 10"0.188" Wall Sch. 40 –1020 lbf (4.54 Kn) 850 lbf (3.78 Kn) 1000 lbf (4.45 Kn) 1100 lbf (4.89 Kn) 1700 lbf (7.56 Kn) 2410 lbf (10.72 Kn) 2950 lbf (13.12 Kn) 3290 lbf (14.63 Kn) 12"0.188" Wall Sch. 40 –970 lbf (4.31 Kn) 1010 lbf (4.49 Kn) 1220 lbf (5.43 Kn) 1430 lbf (6.36 Kn) 1690 lbf (7.52 Kn) 2390 lbf (10.63 Kn) 2930 lbf (13.03 Kn) 3270 lbf (14.55 Kn) Brace Pipe Angles are determined from Vertical. Sch. 10 & 0.188" Wall Load Ratings may be used for any thicker wall pipe of the same diameter. Load ratings include a minimum safety factor of 1.5 in accordance with NFPA 13-2016 Section A.9.3.5.2.3. To convert the load ratings above to a safety factor of 2.2 per NFPA 13-2019 Section A.18.5.2.3, multiply load ratings by a factor of 0.68. To convert to LRFD Load Ratings, ASD Load Ratings may be multiplied by a factor of 1.5. See table on page 4 for FM approved metric service pipes. See table on page 4 for FM approved brace members. Longitudinal Application Lateral Application Riser Application SEISMIC BRACES PH-07.20 Fig. AF730 Longitudinal & Lateral Seismic Clamp (cont.) FIG. AF730 cULus Listed & FM Approved Brace Members Brace Member Sizes Standards (or Equivalent) UL Listed FM Approved Sch. 40 NPS Pipe 1", 1¼", 1½", 2"ASTM A53, A106, A135, or A795 3 3 Sch. 40 Metric Pipe DN25, DN32, DN40, DN50 KS D 3562 3 3 Metric Pipe EN10255H 3 GB/T 3091 3 JIS G3454 3 FIG. AF730 cULus Listed & FM Approved Metric Service Pipes Brace Member Service Pipe Sizes UL Listed FM Approved KS D 3507 KS D 3537 DN25, DN32, DN40, DN50, DN 80, DN100 3 3 KS D 3562 Sch. 40 3 3 GB/T 3091 GB/T 3092 3 JIS G3452 3 EN 10255M EN 10255H Installation Instructions Method 1 – Connection to Brace Member First 1. Slide the brace member over the lower jaw until it contacts the back wall of the brace member attachment fitting. 2. Hand tighten the set screw until it contacts the brace member. Continue to torque the set screw until the head breaks off. 3. Rotate the brace assembly to the service pipe. Unbolt the back nut & bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 4. Hand tighten the nuts on both sides of the clamp. Evenly and alternately torque the nut until the head breaks off. It is best practice to tighten the nut at the jaw side first. 5. Ensure the brace angle is within the range specified. Method 2 – Connection to Service Pipe First 1. Unbolt the back nut & bolt and rotate the clamp halves over the service pipe. Re-assemble the nut and bolt. 2. Hand tighten the nuts on both sides of the clamp. Evenly and alternately torque the nut until the head breaks off. It is best practice to tighten the nut at the jaw side first. 3. Slide the brace member over the lower jaw until it contacts the back wall of the brace member attachment fitting. 4. Hand tighten the set screw until it contacts the brace member. Continue to torque the set screw until the head breaks off.