Loading...
HomeMy WebLinkAboutINSPECTION REPORT SUMMARY - 22-00130 - Valley Wide Coop - Fuel Canopy Addition 1753 Precision East Drive  Idaho Falls, ID 83402  (208) 529-8242  Fax (208) 529-6911 oneatlas.com Brandon Lobo Phone: 208-324-8000 Valley Wide Co-Operative, Inc. Fax: 2114 N. 20th St. Other: E-REPORTS ONLY Nampa, ID 83687 Project: Valley Wide, Site Improvements, 1175 W. Main Street, Rexburg, ID Permit #: 22-00130 Project Manager: Derrick Fontes File #: E222187c SUMMARY INSPECTION REPORT This letter is to confirm that, in accordance with Chapter 17 of the 201 8 International Building Code, the project specifications, and the project scope of services, Atlas Technical Consultants personnel have performed special inspections of the following items:  Geotechnical inspection and recommendations  Structural fill density testing  Reinforced concrete testing and inspection We confirm that, to the best of our knowledge, the requirements of the 2018 International Building Code and the approved plans and specifications have been complied with, insofar as meeting the portion of the aforementioned inspections requiring special inspection under Chapter 17 of the IBC, except as noted below:  c7177rev – Placement time exceeded and slump did not meet project requirements. o 28-day strengths found to meet project requirements.  Final acceptance to be determined by the Engineer.  c1573rev – 28-day strengths did not meet project requirements. o 56-day strengths found to meet project requirements.  Final acceptance to be determined by the Engineer.  c8459, c8510, c8577 – 28-day strengths have not been obtained at the time of this report. o 7-day strengths found to meet project requirements.  Final acceptance to be determined by the Engineer.  C8651 – 28-day strength have not been obtained at the time of this report. o 7-day strength is at 92% of the specified project requirements.  Final acceptance to be determined by the Engineer. Tests and inspections were performed only when Atlas was scheduled to do so. A guarantee that the contractor has necessarily constructed the structure in full accordance with the plans and specifications is neither intended nor implied. If there are questions concerning this letter (Summary Inspection) or if Atlas can be of further assistance, please contact the project manager at (208) 529-8242. Respectfully submitted, Atlas Technical Consultants, LLC 1753 Precision East Drive  Idaho Falls, ID 83402  (208) 529-8242  Fax (208) 529-6911 oneatlas.com Colton Bedke, P.E. Reviewed by: Derrick Fontes Transportation Engineer Idaho Falls Branch Manager cc: Joseph Carson; Matthew Hill, Keller Associates; 12/23/22