Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 22-00332 - Rexburg FM Office - RemodelAuthor Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2330 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Don Allen Don.Allen@rexburg.org 208-372-2174 Description : Rexburg FM Office - Remodel Address : 434 E 2nd N Record Type : Commercial - Remodel Document Filename : 21013 - Rexburg FM Toilet Remodel - Bid Set.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 22-00332 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments TS1.1 Stamp Cody Jones : Building Open 1 Approved - Building Inspector TS1.1 Free text Cody Jones : Building Open 1 All construction and materials will need to be in compliance with 2018 IBC. TS1.1 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector TS1.1 Free text Alex Owens : Electrical Open 1 All electrical work must meet 2017 NEC requirements TS1.1 Stamp Don Allen : Mechanical Open 1 Approved - Plumbing Inspector TS1.1 Stamp Don Allen : Mechanical Open 1 Approved - Mechanical Inspector TS1.1 Stamp Don Allen : Mechanical Open 1 Approved - Mechanical Inspector Commercial - Remodel Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) TITLE SHEET, INDEX & KEY PLAN T S 1 . 1 N N 990 JOHN ADAMS PARKWAY P.O. BOX 2212 - IDAHO FALLS, IDAHO 83402-2212 (P) 208-522-8779 (F) 208-522-8785 (W) nbwarchitects.com ARCHITECTURE PLANNING INTERIORS architects p.a.nbwD R A W I N G N O . : R E V I S I O N S PROJECT: SHEET TITLE: P R O J E C T N O . D A T E : D R A W N B Y : C H E C K E D B Y : REXBURG FM OFFICE/JR. SEMINARY REXBURG IDAHO NORTH STAKE PROPERTY NO. 511-3067 TOILET ROOM ADDITION FOR: G L N 2 1 0 1 3 M A Y 2 0 2 2 C J R 05-16-2022 All construction and materials will need to be in compliance with 2018 IBC. All electrical work must meet 2017 NEC requirements 990 JOHN ADAMS PARKWAY P.O. BOX 2212 - IDAHO FALLS, IDAHO 83402-2212 (P) 208-522-8779 (F) 208-522-8785 (W) nbwarchitects.com ARCHITECTURE PLANNING INTERIORS architects p.a.nbwD R A W I N G N O . : R E V I S I O N S PROJECT: SHEET TITLE: P R O J E C T N O . D A T E : D R A W N B Y : C H E C K E D B Y : REXBURG FM OFFICE/JR. SEMINARY REXBURG IDAHO NORTH STAKE PROPERTY NO. 511-3067 TOILET ROOM ADDITION FOR: G L N 2 1 0 1 3 M A Y 2 0 2 2 C J R 05-16-2022 A 1 . 1 DEMOLITION AND CONSTRUCTION FLOOR AND CEILING PLANS N N N N S C A L E : A 2 . 1 INTERIOR ELEVATIONS, SCHEDULES AND DETAILS 990 JOHN ADAMS PARKWAY P.O. BOX 2212 - IDAHO FALLS, IDAHO 83402-2212 (P) 208-522-8779 (F) 208-522-8785 (W) nbwarchitects.com ARCHITECTURE PLANNING INTERIORS architects p.a.nbwD R A W I N G N O . : R E V I S I O N S PROJECT: SHEET TITLE: P R O J E C T N O . D A T E : D R A W N B Y : C H E C K E D B Y : REXBURG FM OFFICE/JR. SEMINARY REXBURG IDAHO NORTH STAKE PROPERTY NO. 511-3067 TOILET ROOM ADDITION FOR: G L N 2 1 0 1 3 M A Y 2 0 2 2 C J R 05-16-2022 1 0 1 990 JOHN ADAMS PARKWAY P.O. BOX 2212 - IDAHO FALLS, IDAHO 83402-2212 (P) 208-522-8779 (F) 208-522-8785 (W) nbwarchitects.com ARCHITECTURE PLANNING INTERIORS architects p.a.nbwD R A W I N G N O . : R E V I S I O N S PROJECT: SHEET TITLE: P R O J E C T N O . D A T E : D R A W N B Y : C H E C K E D B Y : REXBURG FM OFFICE/JR. SEMINARY REXBURG IDAHO NORTH STAKE PROPERTY NO. 511-3067 TOILET ROOM ADDITION FOR: G L N 2 1 0 1 3 M A Y 2 0 2 2 C J R 010 F 1 . 1 SIGNAGE & FURNISHING PLANS AND SCHEDULES N N S C A L E : 1 / 2 " = 1 ' - 0 " P R O J E C T N O , D A T E : D R A W N B Y : PROJECT:R E V I S I O N S SHEET TITLE: C H E C K E D B Y : D R A W I N G N O . : 2 2 0 2 6 M A Y 2 0 2 2 D H A N S E N J S A I L S B E R Y E n g i n e e r e d S y s t e m s A s s o c i a t e s REXBURG FM OFFICE / JR. SEMINARY REXBURG IDAHO NORTH STAKE TOILET ROOM ADDITION FOR: PROPERTY NO. 511-3067 FLOOR PL A N - D E M O L I T I O N N o r t h SCALE: 1/8" = 1'-0" E N L A R G E D F L O O R P L A N - M E C H / P L U M B N o r t h S C A L E : 1 / 4 " = 1 ' - 0 " E X I S T I N G 4 " S S EXI S T I N G 4" S S TO EXISTINGMAN HOLE INSTREET P L A N N O T E S : 1 E X I S T I N G F I X T U R E T O R E M A I N . P R O T E C T I N P L A C E D U R I N G C O N S T R U C T I O N . E X I S T I N G F I X T U R E T O B E R E M O V E D A N D D I S P O S E D O F . D E M O H O T A N D C O L D P I P I N G F R O M E X I S T I N G S I N K T O W A T E R M A I N S A B O V E W A T E R H E A T E R . D E M O E X I S T I N G 1 - 1 / 2 " S A N I T A R Y L I N E F R O M S I N K C A P A T T E E . E X I S T I N G 1 - 1 / 4 " V E N T A N D 2 " S A N I T A R Y T O R E M A I N . C O N N E C T H O T A N D C O L D W A T E R A T E X I S T I N G 3 / 4 " M A I N S A B O V E W A T E R H E A T E R . C O N F I R M E X I S T I N G C O N D I T I O N S . P R O V I D E B A L L V A L V E S A N D I N S T A L L W A T E R L I N E S H I G H I N C E I L I N G S P A C E A N D S H A L L N O T T O I M P E D E T H E A C C E S S . C O N N E C T 1 / 2 " C W T O T R A P P R I M E R . E X I S T I N G S A N I T A R Y L I N E T O R E M A I N . B O R E 4 " S A N I T A R Y U N D E R S T O R A G E A N D M E C H A N I C A L R O O M F L O O R S A T A P P R O X I M A T E L Y 4 8 " B E L O W G R A D E . C O N F I R M E X I S T I N G C O N D I T I O N S A N D P A T H O B S T R U C T I O N S P R I O R T O W O R K . C O N N E C T T O E X I S T I N G 4 " S A N I T A R Y L I N E . V E R I F Y E X I S T I N G C O N D I T I O N S P R I O R T O D E M O L I T I O N . C O N N E C T T O E X I S T I N G 4 " V E N T A B O V E 2 N D R O O F . V E R I F Y E X I S T I N G C O N D I T I O N S P R I O R T O W O R K . S E A L R O O F P E N E T R A T I O N S . E X T E N D 6 " E X H A U S T V E N T T O R O O F W I T H R O O F C A P . C U T , F L A S H , A N D R E P A I R R O O F T O B E W A T E R T I G H T . N O W O R K T O B E D O N E I N T H I S S P A C E . P R O T E C T D U R I N G C O N S T R U C T I O N . R E M O V E A N D R E I N S T A L L P L U M B I N G F I X T U R E A S R E Q U I R E D T O C O M P L E T E F U L L S C O P E O F W O R K . 2 3 4 2 1 3 1 3 4 1 1 1 3 1 3 1 3 1 5 121212121212 1212 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1212 1 2 1 2 1 2 1 2 1 2 1212 1 2 6 3 E X I S T I N G 4 " V E X I S T I N G 4 " V 3 / 4 " C W 1 / 2 " H W 2 " V 2 " V 4 " 4 " 4 " 1 E H 1 E F 1 E F 1 E H F D - 1 F D - 1 W C - 1 W C - 1 T P - 1 L - 1 3 / 4 " C W L - 1 W C O 9 4 1 0 8 7 8 9 1 0 1 1 1 2 1 3 5 5 6 7 7 8 1 1 1 1 1 E X I S T I N G W A T E R H E A T E R MECHANICAL AND PLUMBING DEMOLITION AND FLOOR PLANS M 1 . 1 R E F E R T O E N L A R G E D F L O O R P L A N OFFICEMEN V E S T I B U L E M E C H . R O O M W O M E N ROOM O F F I C E O F F I C E F M O F F I C E F M O F F I C E O F F I C E O F F I C E S T O R . S T O R . STOR.MECH.OFFICEOFFICEMECH.JAN.ROOMROOMROOM R O O M VESTIBULE F O Y E R O F F I C E O F F I C E F M S T O R A G E O F F I C E CORRIDORCORRIDORCORRIDOR C O R R I D O R C O R R I D O R F M O F F I C E F M S T O R A G E C O R R I D O R F M S T O R A G E O F F I C E F M S T O R A G E F M O F F I C E F M O F F I C E O F F I C E R O O M S T O R . S T O R . M E C H . R O O M W O M E N C O R R I D O R W O M E N M E N 1 3 P R O J E C T N O , D A T E : D R A W N B Y : PROJECT:R E V I S I O N S SHEET TITLE: C H E C K E D B Y : D R A W I N G N O . : 2 2 0 2 6 M A Y 2 0 2 2 D H A N S E N J S A I L S B E R Y E n g i n e e r e d S y s t e m s A s s o c i a t e s REXBURG FM OFFICE / JR. SEMINARY REXBURG IDAHO NORTH STAKE TOILET ROOM ADDITION FOR: PROPERTY NO. 511-3067 NO SCALE CEILING MOUNTED EXHAUST FAN DETAIL DAMPER BACK-DRAFT CEILING GRILLECEILING EXHAUST FAN FAN ASSEMBLYCABINETINSULATED ROOF SHINGLES FLASH INTO SHINGLES ANDSEAL WATERTIGHT12x12 ROOF CAP WITHBACK-DRAFT DAMPER(SLOPED ROOF TYPE)10x10 EXHAUST PLENUM6"Ø EA6"Ø EA FAN ASSEMBLYCABINETINSULATED EXHAUST FAN DAMPER BACK-DRAFT NO SCALE TRAP PRIMER DETAIL CONCRETE FILLWATERPROOF MEMBRANEWHERE REQUIREDHORIZONTALRUN IN PIPE 12" MIN. TOSLAB STRUCTURAL BREAKING PORTS AIR GAP VACUUM FIXTURE NEAREST FLOW TOFLOOR DRAINOUTLET TO P-TRAP CEMENT BED FLOORING IF APPLICABLE1/2" PEX TRAP PRIMERBALL TYPE SHUT-OFF VALVE MOUNT IN RECESSED BOX IN WALL. PROVIDE8X8 BOX WITH WITH DOOR.WALL CLEANOUT DETAILNO SCALE 1'-0"1/8 BEND IF CLEANOUTOCCURS AT END OF LINE.WASTE LINE WASTE LINE.LENGTH TO SUIT.1/8 BEND CHROMEWALL COVERAND SCREWFLOOR LINE WALL MAY EXTEND AS AWASTE OR VENTPLUGGED TEEWITH CLEANOUT 1 E F S Y M . E X H A U S T F A N S C H E D U L E V E N T W A S T E H O T C O L D S Y M . F I X T U R E S C H E D U L E D E S C R I P T I O N F D - 1 2 " F L O O R D R A I N - Z U R N Z - 4 1 5 W I T H 5 Ø N I C K E L - B R O N Z E S T R A I N E R , 2 " D E E P S E A L P - T R A P A N D T R A P P R I M E R . - - - 2 " 1 / 2 " - - - L - 1 1 - 1 / 2 " 1 - 1 / 2 " 1 / 2 " 1 / 2 " - - - - 1 / 2 " - - T P - 1 2 " 4 " 1 / 2 " - - - W C - 1 A D A W A L L H U N G L A V A T O R Y - K O H L E R K - 2 0 3 1 - 0 " G R E E N W I C H " W I T H W A L L C A R R I E R , M O E N 8 4 3 0 F A U C E T & W A T T S S E R I E S L F U S G - B M I X I N G V A L V E , K - 7 7 1 5 O P E N G R I D S T R A I N E R W I T H O F F S E T W A S T E L I N E , 1 / 2 " S T O P S A N D 1 - 1 / 4 " P - T R A P . P R O V I D E I N S U L A T I N G J A C K E T O N H W A N D W A S T E P I P I N G . R E M A R K S R . P . M . W A T T S C H A R . C O N T R O L C . F . M . T Y P E S . P . E . S Y M . C E I L I N G M O U N T E D 1 0 0 T W I N C I T Y T 1 5 0 W I T H B A C K D R A F T D A M P E R A N D 6 " Ø D U C T U P T H R U W A L L A B O V E T O R O O F C A P 0 . 3 7 5 " 1 0 0 1 2 0 / 6 0 / 1 7 0 0 A D A T A N K T Y P E W A T E R C L O S E T - O W N E R P R O V I D E D , C O N T R A C T O R I N S T A L L E D . W A T E R C L O S E T W / E L O N G A T E D B O W L , W H I T E O P E N F R O N T S E A T , A N D B O L T C A P S . T R A P P R I M E R - Z U R N Z 1 0 2 0 X L T R A P P R I M E R . M O U N T R E C E S S E D I N W A L L B E L O W S I N K A N D P R O V I D E L O C K E D C O V E R . R U N 1 / 2 " C O L D W A T E R L I N E T O E A C H T R A P . R E F E R T O D E T A I L O N M P 1 . 2 F O R T Y P I C A L I N S T A L L A T I O N . W I T H L I G H T S E L E C T R I C H E A T E R S C H E D U L E E H 1 S Y M . T Y P E K W C H A R C O N T R O L R E M A R K S W A L L M O U N T E D 0 . 3 7 5 1 2 0 / 6 0 / 1 I N T E G R A L Q M A R K G F R 1 5 0 0 T 2 F T - S T A T MECHANICAL AND PLUMBING SCHEDULES M 1 . 2 S CD2 SCD2 F F CORRIDOR CORRIDOR WOMEN MECH. ROOM STOR. STOR. MEN WOMEN 3 3 3 3 3 3 3 'A'42" 42" 5 5 6 F1 F1 EF-1 120 V/1P100 W EF-1 120 V/1P100 W EH-1 120 V/1P375 W EH-1 120 V/1P375 W A-25 CORRIDOR CORRIDOR WOMEN MECH. ROOM STOR. STOR. WORK ROOM 'A'1 'SOUND SYSTEM' 2 3 3 3 3 3 3 3 4 ELECTRICAL SPECIFICATIONS 1. INTENT: Provide and install complete and operable electrical systems including but not not limited to; lighting, power, receptacles, data, fire alarm ande etc. Provide all required connections to all Mechanical and Plumbing equipment, as indicated and required, including all conduits, wiring and controls. Coordinate with mechanical contractor and drawings. 2. COMPLIANCE WITH CODES: All work and material shall comply with all applicable codes, safety orders, laws, ordinances and regulations of governing authorities and other agencies having jurisdiction including regulations of the State and Local Fire Marshall, unless detailed as specified to a more restrictive standard or higher requirement. 3. INTERPRETATION OF DRAWINGS: The electrical drawings are essentially diagrammatic in that all provisions necessary to conform to structural, architectural, mechanical and plumbing systems can not be shown. All installations shall be adjusted as necessary to conform and to avoid obstructions, without additional cost to the owner. All work, material and equipment called for by notes, schedules or otherwise indicated on the drawings shall be furnished and isntalled as though fully set forth in these specifications. 4. VISITING THE SITE: Contractor shall visit the site and become acquainted with conditions to be encounterd. Extra funds will not be allowed due to failuer to examine the site and to included existing conditions in bid price. 5. COORDINATION WITH UTILITIES: These plans have been prepared without utility company comments. The contractor shall verify exact requirements for the electrical, telephone and communication services with the utility company representatives and provide all work and pay all costs for a complete and operating systems, as directed by the governing utilities. 6. MATERIALS AND WORKMANSHIP: All workmanship shall be performed by skilled electricians using the best standard practives of the trade. All materials shall, unless otherwise noted, be new and in perfect condition and working order. All material for similar uses shall be of the same type, material and manufacturer for ease of future maintaenance. All equipment shall be readily accessible for maintenance and repairs. All materials, fixtures and equipment shall be covered or sealed upon installation so as to provide for safety and to insure that operation and appearance will be maintained after subsequent construction operations. 7. EXECUTION: Raceway installation: Seperate underground conduits in a common trench 4" minimum horizontally, 12" minimum from other utility lines. Minimum conduit depth shall be 18". Coordinate conduit installation with pipes, steel, footings and ducts installed by other trades. Install conduit runs exposed to view parallel or at right angles to structural members, walls or building lines. Support conduit with one-hole malleable factory made pipe straps, fastended with screws. 8. OPERATING AND ADJUSTING: The owner reserves the right to operate any systems of equipment prior to final comletion and acceptance of the work. Such perliminary operation shall not be construed as an acceptance of any work. Each piece of equipment and all of the systems shall be adjusted to insure proper functioning and shall be left in first class operating condition. 9. CUTTING AND PATCHING: Do all drilling and cutting as necessary for installation of equipment or conduit. Cutting or drilling of structure is only permitted with prior approval of the owner and structural engineer. Where cutting and patching of work is necessary, use the same materials, workmanship and finish to neatly match all surrounding work. 10. CONDUIT: All conduit material and installation methods shall be as allowed by the NEC, local AHJ and as directed by the owner. 11. CONDUCTORS: Type THWN or THHN copper wire insulated for 600V. Smallest wire shall be #14 AWG unless noted otherwise. All wiring shall be Copper unless indicated otherwise. Type MC cable shall be permitted, provided it is installed in concealed areas and installation complies with the Local AHJ and NEC requirements. Use "Ideal Yellow" pulling compound for all wire pulls. Use Scotchlock connectors for all splices in #12 wire and tape bolted pressure connectors for larger wire. 12. GROUNDING: All conduit, branch circuits, feeders and etc. shall be provided with a grounding conductor. All grounding conductors shall be insulated and green in color, size as shown. 13. WIRING DEVICES: Devices shall be Standard type, Specification grade, color as selected by owner. Decora style devices are prohibited. Utilize GFCI and Tamper-proof devices in all locations as defined by the NEC. Wiring devices shall be as installed as allowed by the NEC, local AHJ. 14. DEVICE PLATES: Devices plate type and color shall be as directed by owner and as required by the NEC. 15. LIGHTING FIXTURES: As selected by owner and/or indicated in schedules. All light fixtures shall be installed and connected by the Electrical Contractor. 16. SERVICE EQUIPMENT & PANELBOARDS: Service Equipment: Shall be rated as such and shall comply with local utility co. requirments. . Panelbards: Shall be provided with typed writtend directories indicating loads being served. Maintain all required clearances around equipment as required by the NEC. All equpment dimensions to be field verified. 17. CLEAN-UP: Upon completion of the work, prior to final inspection, thoroughly clean all exposed fixtures, trim and equipment and leave the entire installation in a neat, clean and usable condition. Remove all cement, paint, grease, oil and other foreign substances. 18. TEST: Test all conductors for shorts, opens, grounds or other defects. Correct any defective work and re-test. Demonstrate continuous satisfactory operation of all electrical systems and equipment. Provide training to the owner on electrical systems as needed for owner operation and maintenance of building. 19. GUARANTEE: Prior to final acceptacne of the project, deliver to the owner a written one year guarantee on all workmanship, materials and equipment and agree to repair or replace all such defective items promptly that may occure during the warranty period; including repair or replacement of the premises that may be damaged due to faulty work and materials furnished under contract. CIRCUITING & GENERAL SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION KEYED NOTE REFERENCE1 BRANCH CIRCUIT HOME-RUN TO PANEL INDICATED A-1,3,5 3/4"C.-6#12,1#12G QTY & SIZE OF EQUIPMENT GROUND CONDUCTOR QTY & SIZE OF NEUTRAL AND PHASE CONDUCTOR(S) SIZE OF CONDUIT A-1,3,5 3/4"C.-6#12,1#12G PANEL AND CIRCUIT DESIGNATIONS EQUIPMENT GROUNDING CONDUCTOR TICK MARKS NEUTRAL CONDUCTOR(S) PHASE AND/OR SWITCH-LEG CONDUCTOR(S) DETAIL # / SHEET REFERENCE1 / ES101 LIGHTING SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION PARKING AREA POLE LIGHT, SINGLE OR DOUBLE HEAD AS INDICATED ON DRAWINGS. REFER TO LIGHT POLE DETAIL FOR POLE INFORMATION. 2X4 FLUORESCENT OR LED FIXTURE 2X2 FLUORESCENT OR LED FIXTURE SURFACE MOUNTED FLUORESCENT OR LED FIXTURE STRIP FLUORESCENT OR LED FIXTURE WALL MOUNTED FLUORESCENT OR LED FIXTURE EXTERIOR WALL MOUNTED FIXTURE ROUND RECESSED FIXTURE SURFACE OR PENDANT FIXTURE LIGHT FIXTURE SUBSCRIPTS NL NIGHT-LIGHT(CONNECT TO UNSWITCHED LEG OF CIRCUIT) EXIT SIGN, WALL OR CEILING MOUNTING AS REQUIRED (SINGLE OR DOUBLE FACE) DIRECTIONAL CHEVRONS AS INDICATED; CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EXIT SIGNS. SHADED FIXTURE INDICATES AN EMERGENCY FIXTURE. PROVIDE WITH EMERG. BATTERY PACK OR CONNECT TO EMERGENCY POWER SYSTEM (WHERE APPLICABLE). CONNECT BATTERY PACK TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT SERVES THE SAME AREA AS THE EMERGENCY FIXTURE. PROVIDE WITH TEST LIGHT AND SWITCH. CEILING MOUNTED OCCUPANCY SENSOR, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR SENSOR TYPE AND ADDITIONAL INFORMATION. SWITCH MOUNTED OCCUPANCY SENSOR, LOW VOLTAGE SWITCHPOD OR DIMMER SWITCH, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR TYPE AND ADDITIONAL INFORMATION. SINGLE-POLE SWITCH (SEE SUB-SCRIPTS BELOW FOR ADDITIONAL INFORMATION) SWITCH SUBSCRIPTS 3 3-WAY SWITCH 4 4-WAY SWITCH D DIMMER SWITCH (COMPATIBLE W/ LOAD & LTG TYPES) F 7-DAY PROGRAMMABLE TIMER SWITCH (INTERMATIC MODEL EI500WC SERIES) P PILOT LIGHTED SWITCH F1 LIGHT FIXTURE TYPE DESIGNATION S ### WALL OR CEILING MOUNTED EMERGENCY LIGHTING UNIT W/BATTERY PACK CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EMERGENCY LIGHT. LV LOW-VOLTAGE SWITCH (PER DWG'S) T THERMAL-OVERLOAD SWITCH M SWITCH SUPPLIED WITH EQUIPMENT, INSTALLED BY E.C. WP WEATHERPROOF 2P DOUBLE POLE, SINGLE THROW SWITCH GENERAL LIGHTING NOTES: A. SYMBOLS SHOWN ABOVE MAY NOT REPRESENT ALL LIGHT FIXTURES USED ON PROJECT, REFER TO LIGHT FIXTURE SCHEDULE FOR ACTUAL FIXTURE INFORMATION INCLUDING FIXTURE TYPE, LAMPING, MOUNTING AND ETC. B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS; E.C. SHALL PROVIDE AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROL SCHEMES INDICATED AND DESCRIBED ON DRAWINGS. INCLUDING ALL 0 - 10V DIMMING CONTROLS BETWEEN SWITCH AND FIXTURES. D. ALL BATTERY EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA. ### F M POWER SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION 'LA' ELECTRICAL PANELBOARD, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) J JUNCTION BOX CR = CORD REEL; SEE DRAWINGS FOR INFORMATION CD = CORD DROP; SEE DRAWINGS FOR INFORMATION EQUIPMENT CONNECTION; COORDINATE CONNECTION WITH EQUIPMENT PRIOR TO ROUGH-IN MOTOR CONNECTION CEILING MOUNTED DUPLEX RECEPTACLE (COORDINATE PLACEMENT WITH CEILING EQUIPMENT PRIOR TO ROUGH-IN) DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT. RECEPTACLE AND EQUIPMENT SUBSCRIPTS AC ABOVE COUNTER WP WEATHERPROOF (UL LISTED WEATHER-RESISTANT) 42"MOUNTING HEIGHT AFF OR AFG IG ISOLATED GROUND S SURGE-PROTECTION TYPE REF REFRIGERATOR W WASHING MACHINE D DRYER (30A-240V RATED RECPT.) M MICROWAVE HVAC THERMOSTAT OR SENSOR; PROVIDE & INSTALL BACKBOX,3/4" CONDUIT AND CONDUCTORS TO ASSOCIATED HVAC UNIT. COORDINATE EXACT LOCATION & SIZE AND NUMBER OF CONDUCTORS WITH M.C. T SOR SMALL EXHAUST FAN CONNECTION TV 120V RECEPT. FOR TV; VERIFY HEIGHT WITH ARCH. DRAWINGS & ELEVATIONS USB 120V RECPT. WITH USB CHARGING PORTS EWC ELECTRIC WATER COOLER; (SEE DETAIL. RECPT. SHALL BE ACCESSIBLE, DO NOT MOUNT BEHIND HOUSING.) DISP GARBAGE DISP. (UNDER SINK) DW DISHWASHER (COORDINATE W/ MILLWORK, INSTALL PER NEC 422.16(B)(2)). M/R MICROWAVE/RANGE HOOD (COORDINATE W/ MILLWORK) R ELECTRIC RANGE (50A-240V RATED RECPT.) GENERAL SPECIAL SYSTEM NOTES: A. ALL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES AS NECESSARY IN ORDER TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN TILEWORK/WALL OR WAINSCOATING, ETC. B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL A GFCI TYPE RECEPTACLE FOR ALL RECPTACLES SHOWN IN TOILET RMS, BATHROOMS, KITCHENS/SERVING AREAS, ROOFTOP, OUTDOORS OR WITHIN 6FT OF ANY SINK, BASIN, TUB OR FLOOR SINK AND ALL OTHER AREAS DEFINED BY THE NEC. 13053 ST ATE O F I D A HOSHAWNA.M E A D O R R E G I S TEREDRP O F E S S I O N AL ENGIN E E R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers PROJECT NO. DATE: DRAWN BY: CHECKED BY: DRAWING NO.: REVISIONS PR O J E C T : SH E E T T I T L E : SAM TEP P.E. #:2250 04/29/22 E0.0 21013 RE X B U R G F M O F F I C E / J R . S E M I N A R Y RE X B U R G I D A H O N O R T H S T A K E EL E C T R I C A L D R A W I N G S APRIL 2022 TO I L E T R O O M A D D I T I O N F O R : PR O P E R Y N O . 5 1 1 - 3 0 6 7 A. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS, HOWEVER THE ABOVE INFORMATION APPLIES. B. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED SWITCH/OUTLET/J-BOXES WHERE REQUIRED. C. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SHALL BE ADAPTED TO NEW WALL COVERINGS, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS, ETC. D. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH THE OWNER. E. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION, DETAILS, ETC. F. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK. G. WHERE EXISTING CIRCUITS ARE TO BE RE-USED, EXTEND AS NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. H. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE-INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION OF EXISTING CIRCUITS OR WIRING. I. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANICAL EQUIPMENT TO BE REMOVED OR RELOCATED. J. REMOVE ALL UNUSED EQUIPMENT WIRING, CONDUIT AND BOXES IN ALL AREAS. ABANDON ONLY IN CONCEALED AREAS. K. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITION AND COMPLIES WITH SPECIFICATIONS. L. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS. M. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT USED IN FINISHED AREAS. GENERAL NOTES: KEY NOTES:# SCALE: 1/4" = 1'-0"2 NEW ELECTRICAL PLAN 8'4'0" NORTH SCALE: 1/4" = 1'-0"1 EXISTING ELECTRICAL PLAN 8'4'0" NORTH 1 ALL EXISTING ELECTRICAL DEVICES IN THIS ROOM ARE TO BE DISCONNECTED AND REMOVED INCLUDING BUT NOT LIMITED TO; LIGHTS SWITCHES RECEPTACLES AND ETC. REMOVE ALL ASSOCIATED CONDUIT/CONDUCTORS WHERE POSSIBLE. LOCATE AND MAINTAIN EXISTING LIGHTING/RECEPT. CIRCUIT(S) AS REQUIRED TO BE UTILIZED FOR NEW DEVICES. MAINTAIN/RE-ESTABLISH CONTINUITY TO ALL DOWNSTREAM EQUIPMENT/DEVICES THAT ARE TO REMAIN. 2 EXISTING SOUND SYSTEM EQUIPMENT TO BE DISCONNECTED AND REMOVED, EXISTING SPEAKER CABLING SHALL BE PULLED BACK TO ABOVE ACCESSIBLE CEILING SPACE, COILED AND ABANDONED. COORDINATE WITH OWNER. 3 ALL EXISTING ELECTRICAL DEVICES AND EQUIPMENT IN THIS ROOM TO REMAIN FUNCTIONAL, LOCATE AND PROTECT DURING CONSTRUCTION. 4 EXISTING SQUARE D 225A MBR, NQO PANELBOARD TO REMAIN. 5 CONNECT EXHAUST FAN TO ROOM LIGHTING CIRCUIT AND CONTROL WITH LIGHTING 6 CONNECT TO EXISTING LIGHTING/RECPT. CIRCUIT MADE AVAILABLE DURING DEMOLITION, FIELD VERIFY HOMERUN LOCATION. LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING VOLTAGE LUMENS COLOR TEMP.(K) MFGR. CATALOG # APPROVED MFGR'S NOTES F1 4FT LED WRAPAROUND SURFACE 120-277 4000 4000 LITHONIA FML4W-48-AL06-SEF-840-MVOLT COOPER LIGHTING CONTROL/OCCUPANCY SENSOR SCHEDULE TYPE DESCRIPTION MFGR. CATALOG # APPROVED EQUALS NOTES OCC. SENSORS - CEILING (LINE VOLTAGE) CD2 DUAL-TECHNOLOGY, LINE VOLTAGE, SMALL MOTION 800W MAX LOAD SENSOR SWITCH CMR PDT 9 COOPER, WATTSOPPER, HUBBELL