Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FA SMOKE SENSOR ADDRESSABLE - 22-00610 - U-Haul - New Commercial Bldg A.pdf
GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2008 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0617 Rev. E1 page 1 of 2 Velociti® Series ASD-PL2F and ASD-PTL2F Analog, Addressable Photoelectronic Smoke Sensor Description The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor’s address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor’s unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-tem- perature thermal sensing on the ASD-PTL2F model. The Velociti® Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to five times greater than earlier designs. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Ordering Information Model Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing Features • Sleek, low-profile design • Visual rotary, decimal switch addressing (01-159) • Built-in functional test switch activated by an external magnet • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm* • Optional relay, isolator, or sounder bases • Low standby current • Analog addressable communication • Stable communication technique with noise immunity • Optional remote, single-gang LED Indicator (RA400Z) • Suitable for installation in ducts • Compatible with Gamewell-FCI analog addressable panels Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. ASD-PTL2FASD-PL2F An ISO 9001-2000 Company APPROVED FM 3023594 SIGNALING 07272-0694:263S1913 MEA Approved 219-02-E Vol.VI GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0617 Rev. E page 2 of 2 www.gamewell-fci.com Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: •4.0" (10.2 cm) square box •3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box • Single-gang box (except relay or isolator bases) • With B501BH or B501BHT base, use a 4.0" (10.2 cm) square box • With B224RB or B224BI base, use a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. Sensor Spacing Gamewell-FCI recommends spacing sensors in com- pliance with NFPA 72. In low airflow applications with smooth ceilings, space sensors 30 feet (9.1 m). For specific information regarding sensor spacing, place- ment and special applications, refer to NFPA 72. Specifications Size: 2.1” (5.1 cm) high x 4.1” (10.4 cm) diameter installed in B501 base, 6.1” (15.5 cm) diameter installed in ADB-FL base. Shipping Weight:5.2 oz. (147 g) Operating Temperature: ASD-PL2F: 32° F to 120° F (0° C to 49° C) ASD-PTL2F: 32° F to 100° F (0° C to 38° C) UL®-Listed Velocity Range: 0-4000 ft./min. (1,219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10-93% (non-condensing) Thermal Ratings:Fixed-temperature setpoint 135° F (57° C) Electrical Specifications VoltageRange: 15 – 32 volts DC peak Standby Current: (max. avg.): .0003 A @ 24 VDC (one communication every 5 seconds with LED enabled) Maximum Alarm Current: .0065 A @ 24 VDC (LED) lit). Bases and Options ADB-FL 6.1” (15.5 cm) diameter B501 4.1” (10.4 cm) diameter B501BH or B501BHT Sounder base assembly (B501BHT produces a temporal pattern). Includes B501 base B224RB Relay Base Screw terminals: Up to 14 AWG (2.0 mm2) Relay type: Form-C Rating: 2.0A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2” x 1.2” (15.7 x 3.0 cm) Maximum: 25 devices between isolator bases. RA400Z Remote alarm indicator, LED. BCK-200 Black detector covers (box of 10)