Loading...
HomeMy WebLinkAboutSTRUCTURAL ANALYSIS - 22-00881 - 2211 W 1000 S - Cell Tower Upgrades kimley-horn.com 421 Fayetteville Street, Suite 600, Raleigh, NC 27601 919 677 2000 Smartlink Group, LLC. 1997 Annapolis Exch. Pkwy #200 Annapolis, MD 21401 (801) 230-4877 Kevin Fraleigh, P.E. 3875 Embassy Pkwy, Suite 280 Akron, OH 44333 (216) 505-8256 Date: November 3,2022 K-H Project #: KHCLE-31359 Comprehensive Structural Analysis Report Carrier Designation: AT&T USID: 129553 FA Number: 10549689 Client Site Number: IDL04341 AT&T Site Name: REXBURG WEST Analysis Criteria: Code Requirements: TIA-222-H, 2018 IBC, & ASCE 7-16 Ultimate Wind Speed w/o Ice: 105 mph (3-sec gust) Wind Speed w/ Ice: 50 mph w/ 0.25” ice Site Data: 2211 West 1000 South, Rexburg, ID 83440, Madison County Latitude 43.8089194° N, Longitude 111.8217472° W AT&T Market: CO/UT/WY/MT/SO. ID 120 ft – EEI Monopole Ms. Tamara Shiveley, Kimley-Horn and Associates, Inc. is pleased to submit this “Comprehensive Structural Analysis Report” to determine the structural integrity of the above mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: Existing+Proposed+Future: Proposed Tower Rating: 39.4% Pass Proposed Foundation Rating: 31.9% Pass This analysis utilizes an ultimate 3-second gust wind speed of 105 mph as required by the 2018 International Building Code. Applicable Standard references and design criteria are listed in Page 2 - Analysis Criteria. Structural analysis prepared by: Deanna Fernando, E.I. Respectfully submitted by: Kevin J. Clements, P.E. Lic. #20007, Exp. 05/31/2024 Kimley-Horn and Associates, Inc. COA #582 FA Number: 10549689 KH Project #: KHCLE-31359 Site Name: REXBURG WEST Page 2 kimley-horn.com 421 Fayetteville Street, Suite 600, Raleigh, NC 27601 919 677 2000 ▪ INTRODUCTION At the request of Smartlink Group, LLC., Kimley-Horn and Associates, Inc. performed a structural analysis of the existing monopole structure located in Rexburg, ID. The purpose of the analysis is to determine the adequacy of the tower to support the loading configuration outlined in Appendix A (Tower Analysis Summary Form), pursuant to the referenced standards. ▪ ANALYSIS CRITERIA The analysis utilizes tnxTower v. 8.1, an industry-standard finite element analysis program, to create an elastic three-dimensional model considering second-order effects per ANSI/TIA-222 requirements. The program calculates member stresses for various loading cases and selected output from the analysis is included in the appendices. TIA-222 Revision: TIA-222-H Risk Category: II Ultimate Wind Speed: 105 mph Exposure Category: C Topographic Factor at Base: 1.00 Topographic Factor at Mount: 1.00 Ice Thickness: 0.25 in Wind Speed with Ice: 50 mph Seismic Design Category: D Seismic Ss: 0.359 Seismic S1: 0.141 ▪ SUPPORTING DOCUMENTATION Information on the current tower geometry, member sizes, foundation dimensions, soil properties, and antenna loading was obtained from the sources listed below. It is assumed that all information provided to Kimley-Horn & Associates, Inc. is accurate. In the absence of information to the contrary, we assume the structure has been properly erected and maintained per the original design drawings and the capacity has not significantly changed from the “as new” condition. Tower Mapping Not Provided Tower Design EEI, Project #: 84690, dated 05/23/2012 Foundation Design Ehresmann Engineering, Project #: 84690, dated 01/05/2012 Geotechnical Report Harper-Leavitt Engineering, Project #: PCTLIDU4276, dated 12/29/2011 Previous Analysis GPD, Project #: 2019723.02.129553.03, dated 02/05/2019 Tower Loading Data AT&T RFDS ID: 5134790, dated 04/26/2022 FA Number: 10549689 KH Project #: KHCLE-31359 Site Name: REXBURG WEST Page 3 kimley-horn.com 421 Fayetteville Street, Suite 600, Raleigh, NC 27601 919 677 2000 ▪ RESULTS The tables below show a maximum usage summary for each group of components in the structure. The usage of a component is the ratio of force in the member compared to its calculated capacity. A more detailed report of member usages can be found in the appendix at the end of this report. Usages greater than 100% indicate where the force in the member exceeds its capacity. Usages up to 105% are considered acceptable per industry standard practice. Structure Usages: Structure Component Controlling Usage Result Pole 30.7% Pass Base Plate 39.4% Pass Anchor Rods 32.7% Pass Foundation Usages: Structure Component Controlling Usage Result Base Foundation 31.9% Pass ▪ CONCLUSIONS AND RECOMMENDATIONS Per our structural analysis, the structure has been found to pass. The tower and foundation can support the referenced loading in accordance with the structural strength requirements of ANSI/TIA-222-H and 2018 IBC. FA Number: 10549689 KH Project #: KHCLE-31359 Site Name: REXBURG WEST Page 4 kimley-horn.com 421 Fayetteville Street, Suite 600, Raleigh, NC 27601 919 677 2000 ▪ ASSUMPTIONS AND LIMITATIONS This report is not a condition assessment of the tower and foundation; It is an engineering analysis based upon the theoretical capacity of the structure. Unless told otherwise, we assume the tower and foundation to be in “like new” condition. It is the responsibility of our client and the tower owner to verify that the tower modeled and loading considered is accurate. If these assumptions are not accurate, Kimley-Horn & Associates, Inc. should be notified immediately to perform a revised analysis. This analysis assumes all antenna mounts are adequate to support the existing and proposed loads. It is the carrier’s responsibility to ensure antenna mount meets the structural requirements of ANSI/TIA-222. Kimley-Horn & Associates, Inc. did not analyze antenna supporting mounts as part of this structural analysis report. All services are performed, results obtained, and recommendation made in accordance with generally accepted engineering principles and practices. Kimley-Horn & Associates, Inc. is not responsible for the conclusions, opinions and recommendations made by others based on the information in this report. Kimley-Horn makes no warranties, expressed or implied in connection with this report and disclaims any liability arising from original design, material, fabrication, and section deficiencies or corrosion of the tower. FA Number: 10549689 KH Project #: KHCLE-31359 Site Name: REXBURG WEST Page 5 kimley-horn.com 421 Fayetteville Street, Suite 600, Raleigh, NC 27601 919 677 2000 APPENDIX A Tower Analysis Summary Form Tower Analysis Summary Form General Info Site Name Site Number FA Number Date of Analysis Company Performing Analysis Tower Info Date Design Parameters Analysis Results (% Maximum Usage) Tower Type (G, SST, MP)Design Code Used Tower Height (top of steel AGL) Tower Manufacturer Location of Tower (County, State) Tower Model Ultimate Wind Speed (mph) Tower Design 5/23/2012 Ice Thickness (in)Foundation Adequate? Foundation Design 1/5/2012 Risk Category (I, II, III, IV) Geotech Report 12/29/2011 Exposure Category (B, C, D) Tower Mapping Topographic Category (1 to 5) Foundation Mapping Previous Structural Analysis 2/5/2019 Previous Modification Drawings Steel Yield Strength (ksi) Pole 65 Base Plate 50 Anchor Rods 105 Existing / Reserved Loading Antenna Owner Mount Height (ft) Antenna CL (ft)Quantity Type Manufacturer Model Azimuth Quantity Manufacturer Type Quantity Model Size Internal / External AT&T Mobility 119 121 3 Panel Kathrein 80010992 0/120/240 1 Unknown 14' LP Platform 9 Unknown 1-5/8" Internal AT&T Mobility 119 121 3* Panel Kathrein 800 10722 V01 K 0/120/240 on the same mount 4 DC Power #8 AWG Internal AT&T Mobility 119 121 3* TMA Powerwave LGP 18601 on the same mount 2 Fiber 178 Pair Internal AT&T Mobility 119 121 3 RRH Nokia AHLBA on the same mount 1 RET 1/2" Internal AT&T Mobility 119 121 3 RRH Nokia AHFIB on the same mount AT&T Mobility 119 121 3 RRH Nokia AHNA on the same mount AT&T Mobility 119 121 2 DC Unit Raycap DC6-48-60-18-8C-EV on the same mount AT&T Mobility 25 25 1 Dish Andrew VHLPX4-11W-6WH 260.11 1 Unknown Pipe Mount 1 EW90 Elliptical External AT&T Mobility 10 13 2 GPS Unknown GPS behind dish Note: Loading marked with * shall be removed prior to the installation of the proposed equipment and have not been considered in this analysis. All other existing/reserved loading shall be reused. Proposed Loading Antenna Owner Mount Height (ft) Antenna CL (ft)Quantity Type Manufacturer Model Azimuth Quantity Manufacturer Type Quantity Model Size Internal / External AT&T Mobility 119 122 3 Panel Nokia AEQK (Stacked) 0/120/240 on the existing mount 1 DC Power #6 AWG Internal AT&T Mobility 119 122 3 Panel Nokia AEQU (Stacked) 0/120/240 on the existing mount 1 Fiber 24 Pair Internal AT&T Mobility 119 121 1 DC Unit Raycap DC9-48-60-24-8C-EV on the existing mount Note: The proposed loading shall be installed in addition to the remaining existing/reserved equipment at the same elevation. Future Loading Antenna Owner Mount Height (ft) Antenna CL (ft)Quantity Type Manufacturer Model Azimuth Quantity Manufacturer Type Quantity Model Size Internal / External Transmission Line Antenna Mount Transmission Line Mount Transmission Line 1 Not Provided Antenna Antenna Mount Not Provided Not Provided GPD, Project #: 2019723.02.129553.03 0.25 Harper-Leavitt, Project #: PCTLIDU4276 C II 31.9% Yes Not Provided 105 Foundation (%) EEI, Project #: 84690 Ehresmann Engineering #: 84690 2018 IBC & ASCE 7-16 Tower (%) EEI Madison, ID Tower Base (%) 30.7% 39.4% 120' REXBURG WEST The information contained in this summary report is not to be used independently from the PE stamped tower analysis.129553 (IDL04341) 10549689 10/17/22 Kimley-Horn Description MP TIA-222-H,Existing/Reserved + Future + Proposed Condition FA Number: 10549689 KH Project #: KHCLE-31359 Site Name: REXBURG WEST Page 6 kimley-horn.com 421 Fayetteville Street, Suite 600, Raleigh, NC 27601 919 677 2000 APPENDIX B tnxTower Output File Kimley-Horn 421 Fayetteville Street, Suite 600 Raleigh, NC 27601 Phone: (919) 677-2000 FAX: Job: 10549689 - REXBURG WEST Project: KHCLE-31359 Client: AT&T Mobility Drawn by: Deanna.Fernando App'd: Code: TIA-222-H Date: 10/17/22 Scale: NTS Path: K:\NTL_Telecom\Workflow\AT&T\10549689 - 129553\01 - KHCLE-31357 - Smartlink - SA MA CD\tnx\10549689.eri Dwg No. E-1 120.0 ft 79.0 ft 34.0 ft 0.0 ft REACTIONS - 105 mph WIND TORQUE 1 kip-ft 12 K SHEAR 937 kip-ft MOMENT 26 K AXIAL ARE FACTORED ALL REACTIONS S e c t i o n 1 2 3 L e n g t h ( f t ) 41 . 0 0 50 . 0 0 40 . 0 0 N u m b e r o f S i d e s 18 18 18 T h i c k n e s s ( i n ) 0. 2 5 0 0 0. 3 1 2 5 0. 3 1 2 5 S o c k e t L e n g t h ( f t ) 5. 0 0 6. 0 0 T o p D i a ( i n ) 29 . 4 3 7 5 35 . 4 6 8 0 42 . 7 9 1 2 B o t D i a ( i n ) 36 . 8 7 5 0 44 . 5 0 0 0 50 . 0 0 0 0 G r a d e A5 7 2 - 6 5 W e i g h t ( K ) 3. 6 6. 7 6. 2 16 . 6 80010992 w/ MP 119 80010992 w/ MP 119 80010992 w/ MP 119 AEQK AEQU (Stacked) w/ MP 119 AEQK AEQU (Stacked) w/ MP 119 AEQK AEQU (Stacked) w/ MP 119 AHLBA 119 AHLBA 119 AHLBA 119 AHFIB 119 AHFIB 119 AHFIB 119 AHNA 119 AHNA 119 AHNA 119 DC6-48-60-18-8C-EV 119 DC6-48-60-18-8C-EV 119 DC9-48-60-24-8C-EV 119 (2) 8' Pipe Mount (2SCH40) 119 (2) 8' Pipe Mount (2SCH40) 119 (2) 8' Pipe Mount (2SCH40) 119 14.5' LP Platform 119 4' Pipe Mount 25 VHLPX4-11W-6WH 25DESIGNED APPURTENANCE LOADING TYPE TYPEELEVATION ELEVATION 80010992 w/ MP 119 80010992 w/ MP 119 80010992 w/ MP 119 AEQK AEQU (Stacked) w/ MP 119 AEQK AEQU (Stacked) w/ MP 119 AEQK AEQU (Stacked) w/ MP 119 AHLBA 119 AHLBA 119 AHLBA 119 AHFIB 119 AHFIB 119 AHFIB 119 AHNA 119 AHNA 119 AHNA 119 DC6-48-60-18-8C-EV 119 DC6-48-60-18-8C-EV 119 DC9-48-60-24-8C-EV 119 (2) 8' Pipe Mount (2SCH40) 119 (2) 8' Pipe Mount (2SCH40) 119 (2) 8' Pipe Mount (2SCH40) 119 14.5' LP Platform 119 4' Pipe Mount 25 VHLPX4-11W-6WH 25 MATERIAL STRENGTH GRADE GRADEFy FyFu Fu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower designed for Exposure C to the TIA-222-H Standard. 2. Tower designed for a 105 mph basic wind in accordance with the TIA-222-H Standard. 3. Deflections are based upon a 60 mph wind. 4. Tower Risk Category II. 5. Topographic Category 1 with Crest Height of 0.00 ft 6. TOWER RATING: 30.7% Kimley-Horn 421 Fayetteville Street, Suite 600 Raleigh, NC 27601 Phone: (919) 677-2000 FAX: Job: 10549689 - REXBURG WEST Project: KHCLE-31359 Client: AT&T Mobility Drawn by: Deanna.Fernando App'd: Code: TIA-222-H Date: 10/17/22 Scale: NTS Path: K:\NTL_Telecom\Workflow\AT&T\10549689 - 129553\01 - KHCLE-31357 - Smartlink - SA MA CD\tnx\10549689.eri Dwg No. E-7 Feed Line Distribution Chart 0' - 120' Round Flat App In Face App Out Face Truss Leg Face A 79.00 34.00 0.00 120.00 El e v a t i o n ( f t ) (9 ) L D F 7 - 5 0 A ( 1 - 5 / 8 F O A M ) (5 ) 7 / 8 " P o w e r (2 ) 1 / 2 " F i b e r t r u n k 3/ 8 F i b e r 1/ 2 " R E T Face B 8.008.008.008.008.008.008.008.00 25.00 Face C 79.00 34.00 0.00 120.00 8.008.008.008.008.008.008.008.00 25.00 St e p P e g s Sa f e t y L i n e 3 / 8 EW 9 0 Kimley-Horn 421 Fayetteville Street, Suite 600 Raleigh, NC 27601 Phone: (919) 677-2000 FAX: Job: 10549689 - REXBURG WEST Project: KHCLE-31359 Client: AT&T Mobility Drawn by: Deanna.Fernando App'd: Code: TIA-222-H Date: 10/17/22 Scale: NTS Path: K:\NTL_Telecom\Workflow\AT&T\10549689 - 129553\01 - KHCLE-31357 - Smartlink - SA MA CD\tnx\10549689.eri Dwg No. E-7 Feed Line Plan Round Flat App In Face App Out Face Safety Line 3/8 (9) LDF7-50A (1-5/8 FOAM) (5) 7/8" Power(2) 1/2" Fiber trunk3/8 Fiber1/2" RET ttnnxxTToowweerr Job 10549689 - REXBURG WEST Page 1 of 5 Kimley-Horn 421 Fayetteville Street, Suite 600 Project KHCLE-31359 Date 16:46:55 10/17/22 Raleigh, NC 27601 Phone: (919) 677-2000 FAX: Client AT&T Mobility Designed by Deanna.Fernando  Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-H standard. The following design criteria apply: Tower base elevation above sea level: 4848.73 ft. Basic wind speed of 105 mph. Risk Category II. Exposure Category C. Simplified Topographic Factor Procedure for wind speed-up calculations is used. Topographic Category: 1. Crest Height: 0.00 ft. Deflections calculated using a wind speed of 60 mph. A non-linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Sector Exclude From Torque Calculation Component Type Placement ft Total Number Number Per Row Start/End Position Width or Diameter in Perimeter in Weight plf Step Pegs C No Surface Ar (CaAa) 120.00 - 8.00 1 1 0.000 0.000 0.8000 2.72 * EW90 C No Surface Ar (CaAa) 25.00 - 8.00 1 1 0.000 0.000 1.2800 0.32 Feed Line/Linear Appurtenances - Entered As Area Description Face or Leg Allow Shield Exclude From Torque Calculation Component Type Placement ft Total Number CAAA ft2/ft Weight plf Safety Line 3/8 C No No CaAa (Out Of Face) 120.00 - 8.00 1 No Ice 0.04 0.22 * LDF7-50A (1-5/8 FOAM) A No No Inside Pole 120.00 - 8.00 9 No Ice 0.00 0.82 7/8'' Power A No No Inside Pole 120.00 - 8.00 5 No Ice 0.00 0.04 1/2'' Fiber trunk A No No Inside Pole 120.00 - 8.00 2 No Ice 0.00 0.13 3/8 Fiber A No No Inside Pole 120.00 - 8.00 1 No Ice 0.00 0.08 1/2'' RET A No No Inside Pole 120.00 - 8.00 1 No Ice 0.00 0.11 ttnnxxTToowweerr Job 10549689 - REXBURG WEST Page 2 of 5 Kimley-Horn 421 Fayetteville Street, Suite 600 Project KHCLE-31359 Date 16:46:55 10/17/22 Raleigh, NC 27601 Phone: (919) 677-2000 FAX: Client AT&T Mobility Designed by Deanna.Fernando Discrete Tower Loads Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 80010992 w/ MP A From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 19.33 10.34 0.16 80010992 w/ MP B From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 19.33 10.34 0.16 80010992 w/ MP C From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 19.33 10.34 0.16 AEQK & AEQU (Stacked) w/ MP A From Leg 3.00 0.00 3.00 0.0000 119.00 No Ice 11.71 8.64 0.23 AEQK & AEQU (Stacked) w/ MP B From Leg 3.00 0.00 3.00 0.0000 119.00 No Ice 11.71 8.64 0.23 AEQK & AEQU (Stacked) w/ MP C From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 11.71 8.64 0.23 AHLBA A From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 3.67 2.31 0.10 AHLBA B From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 3.67 2.31 0.10 AHLBA C From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 3.67 2.31 0.10 AHFIB A From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 2.85 1.52 0.07 AHFIB B From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 2.85 1.52 0.07 AHFIB C From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 2.85 1.52 0.07 AHNA A From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 1.79 1.15 0.04 AHNA B From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 1.79 1.15 0.04 AHNA C From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 1.79 1.15 0.04 DC6-48-60-18-8C-EV A From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 1.14 1.14 0.03 DC6-48-60-18-8C-EV B From Leg 3.00 0.00 2.00 0.0000 119.00 No Ice 1.14 1.14 0.03 DC9-48-60-24-8C-EV C From Leg 3.00 0.0000 119.00 No Ice 2.74 4.78 0.03 ttnnxxTToowweerr Job 10549689 - REXBURG WEST Page 3 of 5 Kimley-Horn 421 Fayetteville Street, Suite 600 Project KHCLE-31359 Date 16:46:55 10/17/22 Raleigh, NC 27601 Phone: (919) 677-2000 FAX: Client AT&T Mobility Designed by Deanna.Fernando Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0.00 2.00 (2) 8' Pipe Mount (2SCH40) A From Leg 3.00 0.00 0.00 0.0000 119.00 No Ice 1.90 1.90 0.03 (2) 8' Pipe Mount (2SCH40) B From Leg 3.00 0.00 0.00 0.0000 119.00 No Ice 1.90 1.90 0.03 (2) 8' Pipe Mount (2SCH40) C From Leg 3.00 0.00 0.00 0.0000 119.00 No Ice 1.90 1.90 0.03 14.5' LP Platform C None 0.0000 119.00 No Ice 17.46 17.46 1.35 * 4' Pipe Mount C From Leg 0.50 0.00 0.00 0.0000 25.00 No Ice 0.87 0.87 0.02 Dishes Description Face or Leg Dish Type Offset Type Offsets: Horz Lateral Vert ft Azimuth Adjustment ° 3 dB Beam Width ° Elevation ft Outside Diameter ft Aperture Area ft2 Weight K VHLPX4-11W-6WH C Paraboloid w/Shroud (HP) From Leg 1.00 0.00 0.00 20.1100 25.00 4.11 No Ice 13.26 0.09 Maximum Tower Deflections - Service Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 120 - 79 6.018 31 0.3940 0.0010 L2 84 - 34 3.223 31 0.3287 0.0006 L3 40 - 0 0.811 31 0.1778 0.0003 Critical Deflections and Radius of Curvature - Service Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 119.00 80010992 w/ MP 31 5.937 0.3925 0.0011 154865 ttnnxxTToowweerr Job 10549689 - REXBURG WEST Page 4 of 5 Kimley-Horn 421 Fayetteville Street, Suite 600 Project KHCLE-31359 Date 16:46:55 10/17/22 Raleigh, NC 27601 Phone: (919) 677-2000 FAX: Client AT&T Mobility Designed by Deanna.Fernando Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 25.00 VHLPX4-11W-6WH 31 0.397 0.1133 0.0002 17667 Maximum Tower Deflections - Design Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 120 - 79 20.615 12 1.3494 0.0037 L2 84 - 34 11.040 12 1.1259 0.0021 L3 40 - 0 2.780 12 0.6090 0.0011 Critical Deflections and Radius of Curvature - Design Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 119.00 80010992 w/ MP 12 20.338 1.3443 0.0038 45290 25.00 VHLPX4-11W-6WH 12 1.359 0.3883 0.0008 5157 Compression Checks Pole Design Data Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K Pn K Ratio Pu Pn L1 120 - 79 (1) TP36.875x29.4375x0.25 41.00 0.00 0.0 28.3422 -8.24 1658.02 0.005 L2 79 - 34 (2) TP44.5x35.468x0.3125 50.00 0.00 0.0 42.7534 -16.40 2501.08 0.007 L3 34 - 0 (3) TP50x42.7912x0.3125 40.00 0.00 0.0 49.2838 -25.58 2883.10 0.009 Pole Bending Design Data Section No. Elevation ft Size Mux kip-ft Mnx kip-ft Ratio Mux Mnx Muy kip-ft Mny kip-ft Ratio Muy Mny L1 120 - 79 (1) TP36.875x29.4375x0.25 176.92 1362.33 0.130 0.00 1362.33 0.000 L2 79 - 34 (2) TP44.5x35.468x0.3125 512.60 2514.25 0.204 0.00 2514.25 0.000 L3 34 - 0 (3) TP50x42.7912x0.3125 937.02 3146.22 0.298 0.00 3146.22 0.000 ttnnxxTToowweerr Job 10549689 - REXBURG WEST Page 5 of 5 Kimley-Horn 421 Fayetteville Street, Suite 600 Project KHCLE-31359 Date 16:46:55 10/17/22 Raleigh, NC 27601 Phone: (919) 677-2000 FAX: Client AT&T Mobility Designed by Deanna.Fernando Pole Shear Design Data Section No. Elevation ft Size Actual Vu K Vn K Ratio Vu Vn Actual Tu kip-ft Tn kip-ft Ratio Tu Tn L1 120 - 79 (1) TP36.875x29.4375x0.25 6.08 497.41 0.012 0.46 1555.88 0.000 L2 79 - 34 (2) TP44.5x35.468x0.3125 9.16 750.32 0.012 0.54 2832.32 0.000 L3 34 - 0 (3) TP50x42.7912x0.3125 11.97 864.93 0.014 1.08 3763.64 0.000 Pole Interaction Design Data Section No. Elevation ft Ratio Pu Pn Ratio Mux Mnx Ratio Muy Mny Ratio Vu Vn Ratio Tu Tn Comb. Stress Ratio Allow. Stress Ratio Criteria L1 120 - 79 (1) 0.005 0.130 0.000 0.012 0.000 0.135 1.000 4.8.2 L2 79 - 34 (2) 0.007 0.204 0.000 0.012 0.000 0.211 1.000 4.8.2 L3 34 - 0 (3) 0.009 0.298 0.000 0.014 0.000 0.307 1.000 4.8.2 Section Capacity Table Section No. Elevation ft Component Type Size Critical Element P K øPallow K % Capacity Pass Fail L1 120 - 79 Pole TP36.875x29.4375x0.25 1 -8.24 1658.02 13.5 Pass L2 79 - 34 Pole TP44.5x35.468x0.3125 2 -16.40 2501.08 21.1 Pass L3 34 - 0 Pole TP50x42.7912x0.3125 3 -25.58 2883.10 30.7 Pass Summary Pole (L3) 30.7 Pass RATING = 30.7 Pass FA Number: 10549689 KH Project #: KHCLE-31359 Site Name: REXBURG WEST Page 7 kimley-horn.com 421 Fayetteville Street, Suite 600, Raleigh, NC 27601 919 677 2000 APPENDIX C Base Plate & Anchor Rod Calculations Monopole Base Plate Connection #VALUE! Anchor Rod Data Anchor Rod Summary (units of kips, kip-in) (18) 1-1/2" ø bolts (A193 Gr. B7 N; Fy=105 ksi, Fu=125 ksi) on 56" BC Pu_t = 43.19 φPn_t = 132.19 Stress Rating Vu = 0.66 φVn = 82.83 32.7% Base Plate Data Mu = n/a φMn = n/a Pass 62" OD x 1.5" Plate (A572-50; Fy=50 ksi, Fu=65 ksi) Base Plate Summary Stiffener Data Max Stress (ksi):17.75 (Flexural) N/A Allowable Stress (ksi):45 Stress Rating:39.4%Pass Pole Data 50" x 0.3125" 18-sided pole (A572-65; Fy=65 ksi, Fu=80 ksi) 25.58 11.97 Adjusted Pole Reactions FA #10549689 Applied Loads Site Name REXBURG WEST JIRA Ticket #KHCLE-31359 Analysis Considerations Site Info TIA-222 Revision H Grout Considered:No Analysis ResultsConnection Properties Iar (in) 0 Moment (kip-ft) 937.01 Axial Force (kips) 25.58 Shear Force (kips) 11.97 Moment (kip-ft) Axial Force (kips) Shear Force (kips) 0.00 Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 Analysis Date: 10/17/2022CCIplate - Version 4.1.2 FA Number: 10549689 KH Project #: KHCLE-31359 Site Name: REXBURG WEST Page 8 kimley-horn.com 421 Fayetteville Street, Suite 600, Raleigh, NC 27601 919 677 2000 APPENDIX D Foundation Calculations Tower Type: 25.58 kips Capacity Demand Rating Check 11.97 kips 434.32 0.00 0.0%Pass 225.02 11.97 5.3%Pass 5.00 1.59 31.9%Pass 937.01 ft-kips 4267.94 1014.82 23.8%Pass 120 ft 5616.55 984.89 17.5%Pass ft 558.49 0.00 0.0%Pass in 17996.05 45.94 0.3%Pass 0 in 2479.16 376.57 15.2%Pass 778.68 59.78 7.7%Pass 0.190 0.017 8.8%Pass Circular 2688.96 590.93 22.0%Pass 6 ft 0.190 0.000 0.0%Pass 0.5 ft 2688.96 0.00 0.0%Pass 10 34 4 Structural Rating:22.0% Soil Rating:31.9% Tie 3 in 6 ft 24 ft 2.5 ft 8 25 in 60 ksi 4 ksi 150 pcf 110 pcf 6.000 ksf <--Toggle between Gross and Net ksf 34 degrees ft 99 ft Uplift, Puplift: Base Shear, Vu_comp: Groundwater Depth, gw: Rebar Grade, Fy: Dry Concrete Density, δc: Depth, D: Pad Width, W1: Pad Thickness, T: Pad Clear Cover, ccpad: Material Properties Soil Properties Friction Angle, ϕ: Moment, Mu: Flexural 2-way (Tension) (kip*ft) Pad Shear - 2-way (Uplift) (ksi) Pier Properties BP Dist. Above Fdn, bpdist: Bolt Circle / Bearing Plate Width, BC: Flexural 2-way (Comp) (kip*ft) Block Foundation?: Pad Shear - 2-way (Comp) (ksi) Pier Flexure (Tension) (kip*ft) Overturning (kip*ft) Pad Flexure (kip*ft) Pad Shear - 1-way (kips) Pier Compression (kip) Rectangular Pad?: Pier and Pad Foundation FA #: Site Name: Compression, Pcomp: TIA-222 Revision: JIRA Ticket #: Superstructure Analysis Reactions H Monopole 10549689 REXBURG WEST KHCLE-31359 Pier Flexure (Comp.) (kip*ft) Lateral (Sliding) (kips) Bearing Pressure (ksf) Uplift (kips) Foundation Analysis Checks Neglected Depth, N: Uplift Shear, Vu_uplift: Pier Shape: Tower Height, H: Base Face Width, BW: Cohesion, Cu: Ultimate Net Bearing, Qnet: Pad Rebar Quantity (Bottom dir. 2), mp2: Pad Rebar Size (Bottom dir. 2), Sp2: Total Soil Unit Weight, γ: Top & Bot. Pad Rein. Different?: Foundation Bearing on Rock? SPT Blow Count, Nblows: Base Friction, μ: Pier Diameter, dpier: Ext. Above Grade, E: Pier Rebar Size, Sc: Pier Rebar Quantity, mc: Concrete Compressive Strength, F'c: Pier Tie/Spiral Quantity, mt: Pier Reinforcement Type: Pier Clear Cover, ccpier: Pad Properties Pier Tie/Spiral Size, St: Version 4.1.1