HomeMy WebLinkAboutE101 ELECTRICAL SITE PLAN 1-23-15EL E C T R I C A L S I T E PL A N E101 SH E E T T I T L E : SHEET NUMBER: PR O J E C T : SE A L : TH I S D R A W I N G I S C L A S S I F I E D A S PA R T O F A N U N P U B L I S H E D CO L L E C T I O N O F V I S U A L A R T . UN D E R T H E 1 9 7 8 C O P Y R I G H T AC T , I T I S A N E X C L U S I V E OR I G I N A L W O R K O F AU T H O R S H I P . N O N E O F T H E PI C T O R I A L , G R A P H I C O R TE C H N I C A L C H A R T S O R DR A W I N G S D E P I C T E D O N T H I S SH E E T M A Y B E R E P R O D U C E D OR T R A N S M I T T E D I N A N Y F O R M OR B Y A N Y M E A N S W I T H O U T T H E EX P R E S S P R I O R W R I T T E N PE R M I S S I O N O F T H E A R C H I T E C T . TH I S P L A N I S P R O D U C E D O N L Y FO R T H I S P R O J E C T O N T H I S S I T E AN D M A Y N O T B E U S E D A T OT H E R L O C A T I O N S . RE V DA T E DE S C R I P T I O N DO NOT SCALE DRAWING DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N DE S C R I P T I O N MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y MM - D D - Y Y 4123 5 6 DE S C R I P T I O N IS S U E d a t e : 1 1 / 1 7 / 1 4 RE X B U R G , I D PR O J E C T : RE X B U R G B R A N C H CO R N E R O F 2 N D & M A I N S T . MO U N T A I N A M E R I C A C R E D I T U N I O N em a a r c h i t e c t s │29 0 9 W A S H I N G T O N B L V D - O G D E N , U T 8 4 4 0 1 │PH : 8 0 1 - 6 1 8 - 3 4 6 3 6" 4" CHROMALOX MINERAL INSULATED CABLE "M,.I." @ MIDSLAB TYP. 4" MIN. CONCRETE SIDEWALK 6" SLOPE TO DRAIN AWAY FROM SENSORSET SWITCH LEVEL WITH ADJACENT CONCRETE SIT - 6E SNOW SWITCH 4" MIN. CONCRETE SLAB MASONRY UNIT BLOCKING(3/4") CONDUIT TO WALL CONROLLER TYP. 1/2" 6" 6" 3 E101 SLOPE TO DRAIN AWAY FROM SENSOR SIT - 6E SNOW SWITCH (3/4") CONDUIT TO WALL CONROLLER EDGE OF CONCRETE SLAB 1/2" 6" 2 1 ELECTRICAL SITE PLAN 2 ICE MELT PATH SECTION SCALE: 1" = 1'-0" 3 ICE MELT PATH SENSOR SECTION SCALE: 1" = 1'-0" 4 ICE MELT PATH SENSOR PLAN VIEW SCALE: 1" = 1'-0" 1 1 2 3 1 2 3 1 3 3 2 SITE ELECTRICAL KEYED NOTES CIRCUITS 1"C-2#10, 1#10 GND MINIMUM, ROUTE THROUGH LIGHTING CONTACTOR PANEL PER BUILDING LIGHTING CONTROLS SCHEMATIC SH. E511. EXTEND (2) 1" CONDUITS WITH PULL STRING FROM I.T. CABINET WITH (2) #10 AND (1) #12 GND. THHN CU. WITH POWER AND DATA FROM SIGN LOCATION TO PANEL. ROUTE CIRCUITING THROUGH LIGHTING CONTACTOR PER BUILDING LIGHTING CONTROLS SH. E511. VERIFY LOCATION OF SIGN PRIOR TO ROUGH- IN. EXTEND 1" CONDUIT WITH (2) #10 AND (1) #12 GND. THHN CU. FROM SIGN LOCATION TO PANEL ROUTE CIRCUITING THROUGH LIGHTING CONTACTOR PER BUILDING LIGHTING CONTROLS SH. E511. VERIFY LOCATION OF SIGNS PRIOR TO ROUGH-IN. DE-ICING KEYED NOTES CHROMOLOX "M.I." CABLE @ MID SLAB DEPTH @ 6" O.C. THROUGHOUT DE-ICING AREA. INSTALL PER MANUFACTURERS SPECIFICATIONS. CHORMOLOX "SIT-6E" PAVEMENT SENSOR LOCATE & INSTALL PER MANUFACTURERS SPECIFICATIONS. CHROMOLOX "APS-4C" WALL MOUNT CONTROLLER. SEE E521 FOR POWER CIRCUIT. 2 1 / 2 3 / 1 5 C I T Y C O M M E N T S