HomeMy WebLinkAboutDESIGN LOAD - 21-00656 - 2911 S Frontage Rd - Carpet Direct124 Kirby Dr Version 2020.01.20 (1/20/20) 1050 North Watery Lane Ph: (435) 919-3100 Portland, TN 37148 Brigham City, UT 84302 Fax: (435) 919-3101 Ph: (615) 325-4165 Fax: (800) 231-3460 Ultimate Steel Erection Inc Project Name:Carpet Direct 2621 S Frontage Road Buildings: Rexburg, ID 83440 Attn.:Trever Poulsen Project Location:Rexburg, ID 83440 NBG Project #:U21M0716A This Letter of Design Certification ensures that the materials furnished by the metal building supplier are designed in accordance with the information specified to the metal building supplier on the order documents and summarized by the loading information listed below. The Project Engineer of Record (not the metal building supplier) is responsible for verifying that the building code and design loads meet any and all applicable local requirements. The Professional Engineer whose seal appears on this Letter of Certification is employed by the metal building manufacturer. and does not serve as or represent the Engineer of Record for this project and shall not be construed as such. DESIGN LOAD CRITERIA: Structural Loads Applied in General Accordance with: IBC 2018 Risk Category:II - Standard Buildings PROJECT-WIDE LOADING INFORMATION: Ground Snow Load: 50.0 psf Snow Exposure Factor,Ce: 1.00 Snow Imp. Factor, Is: 1.00 Roof Live Load: 20.0 psf Not Reducible Per Code.Rain Intensity, R: 4.0 in/hr Ultimate Design Wind Velocity: 115 mph Nominal Design Wind Velocity: 89 mph ***Components & Cladding Pressures: 29 psf/ -38 psf Is Roof to meet UL 90 Requirements?: No Wind Exposure: C Seismic Criteria: Ss: 0.366 S1: 0.142 • 20% of flat roof snow included in seismic calc's. Design Sds / Sd1: 0.368/0.219 Analysis Procedure: Equiv. Lat. Force Procedure Seis. Imp. Factor, Ie: 1.00 Basic SFRS: Ord. Steel Mom. Frames & Seis. Design Category: D Site Class: D Ord. Steel Conc.-Br. Frames BUILDING-SPECIFIC LOADING INFORMATION: Roof Dead Bldg (psf)* Pri (psf) Sec (psf) Ct Cs Ps (psf) **Pm (psf) Enclosure GCpi R Cs V (kips) MAIN 4.25 5.00 5.00 1.00 1.00 35.00 20.00 Enclosed ± 0.18 3.25 0.113 43.65 REMNANT 4.25 5.00 5.00 1.00 1.00 35.00 20.00 Enclosed ± 0.18 3.25 0.113 7.93 *Primary Structural Not Included Mezzanine Information: Floor Dead Load: N/A Floor Collateral Load: N/A Floor Live Load: N/A Crane Information: No cranes on building. Roof-Top Unit Information No roof-top units on building. The design of structural members supporting roof gravity loads is controlled by the more critical effect of roof live load or roof snow applied in accordance with the governing building code. DESIGN STANDARDS REFERENCED: • AISC Specification for Structural Steel Buildings - Steel Construction Manual, 15th Edition, © 2017. • AISI North-American Specification for the Design of Cold-Formed Steel Structures, © 2016 Edition. • IBC codes are designed in accordance with ASCE7-16 Edition. • MBMA Low Rise Building Systems Manual, Latest Edition. • AWS Latest Edition of Structural Welding Code. • No buyout structural components provided on this project. (RCS,1.0:12) **P m is based on the minimum roof snow load calculated per building code or the contract-specified roof snow load, whichever is greater. This value, P m , is only applied in combination with Dead and Collateral Loads. Roof Snow in other loading conditions is determined per the specified Building Code. ***Ultimate Design wind pressures to be used for wall exterior component and cladding materials not provided by Metal Building Supplier July 7, 2021 A->107'-0"x165'-0"x22'-0"(RCS,1.0:12); B->60'-0"x31'-0"x22'-0" Collateral Dead Wind SeismicSnow Coefficient Snow Load (psf) Professional Seal 09/28/2021