IMAGE OF INFLOOR HEAT 2 - 21-00776 - 3730 Henry's Fork Way - New SFR Mechanical.PDF
Circuit A-1 250 ft @ 16 in Flow: 0.67 USGPM ΔT: 20 °F Circuit A-2 250 ft @ 16 in Flow: 0.82 USGPM ΔT: 20 °F Circuit A-3 300 ft @ 15 in Flow: 0.84 USGPM ΔT: 20 °F Circuit A-4 300 ft @ 15 in Flow: 0.87 USGPM ΔT: 20 °F Circuit A-5 300 ft @ 15 in Flow: 0.85 USGPM ΔT: 20 °F Circuit A-6 300 ft @ 15 in Flow: 0.83 USGPM ΔT: 20 °F Circuit A-7 300 ft @ 15 in Flow: 0.83 USGPM ΔT: 20 °F Circuit A-11 284 ft @ 16 in Flow: 0.79 USGPM ΔT: 20 °F Circuit A-12 284 ft @ 16 in Flow: 0.78 USGPM ΔT: 20 °F Circuit A-13 284 ft @ 16 in Flow: 0.82 USGPM ΔT: 20 °F Circuit A-10 245 ft @ 16 in Flow: 0.70 USGPM ΔT: 20 °F Circuit A-9 244 ft @ 16 in Flow: 0.62 USGPM ΔT: 20 °F Circuit A-8 242 ft @ 16 in Flow: 0.79 USGPM ΔT: 20 °F PAGE NO.CUSTOMER:PROJECT:DRAWN BY: DRAWING NAME: PROJECT NO.: SCALE: DATE: DISCLAIMER: Ground Floor 1 1/4"=1' 9/30/2021 Cheyne(Shane) GrimesTravis BakerNote: Details of the tubing bend radius have been simplified for clarity. Consult tubing manufacturer for specific bend radius recommendations. Created Using LoopCAD 2021 21.0.0080 (10/6/2021) REVISIONS No Desc Date 1